Loading...
Planning Commission Agenda - 02/22/2022 (Special Meeting)AGENDA SPECIAL MEETING - MONTICELLO PLANNING COMMISSION Tuesday, February 22, 2022 — 6:00 p.m. Mississippi Room, Monticello Community Center Commissioners: Paul Konsor, Andrew Tapper, Alison Zimpfer, Eric Hagen and Teri Lehner Council Liaison: Charlotte Gabler Staff: Angela Schumann, Steve Grittman (NAC), Ron Hackenmueller, Hayden Stensgard 1. General Business A. Call to Order 2. Joint Meeting Agenda A. Public Hearing - Consideration of a Conditional Use Permit for a Place of Public Assembly in the B-3, Highway Business District and Consideration of a Variance to allow a Conditional Use Permit on a lot 10 acres or less in the B-3, Highway Business District and Consideration of amending City Code Section 5.2(D)(6)(F)(i) for parcel size for Places of Public Assembly. Applicant: Alive! Lutheran Church 3. Adjournment Planning Commission Agenda — 02/22/2022 2A. Public Hearine — Consideration of a Conditional Use Permit for a Place of Public Assembly in the B-3, Highway Business District and consideration of a Variance to allow a Conditional Use Permit on a lot 10 acres or less in the B-3, Highway Business District and Consideration of amending City Code Section 5.2(D)(6)(F)(i) for parcel size for Places of Public Assembly. Applicant: Alive! Lutheran Church Prepared by: Northwest Associated Meeting Date: Council Date (pending Consultants (NAC) Commission action): 02/22/2022 02/28/2022 Additional Analysis by: Community Development Director, Chief Building and Zoning Official, Community & Economic Development Coordinator, Project Engineer, Fire Marshal REFERENCE AND BACKGROUND Property: Legal Description: Lot 1, Block 1, Groveland Center PI D: 155-141-001010 Planning Case Number: 2022-07 Request(s): 1. Conditional Use Permit for Place of Public Assembly in the B-3 District. 2. Variance from the lot size requirement for Place of Public Assembly in the B-3 District. 3. Amendment to the Zoning Ordinance to allow Places of Public Assembly in the B-3 District on parcels of less than 10 acres by Interim Use Permit, and an IUP for the current applicant at the subject property. Deadline for Decision: April 8, 2022 (60-day deadline) June 7, 2022 (120-day deadline) Land Use Designation: Regional Commercial Zoning Designation: B-3, Highway Business Overlays/Environmental Regulations Applicable: Freeway Bonus Sign Overlay District Current Site Uses: Commercial Office and Service 1 Planning Commission Agenda — 02/22/2022 Surrounding Land Uses: North: Interstate 94 East: Highway Commercial Uses South: Vacant and Highway Commercial Uses West: Recreational Vehicle Sales Project Description: Location of a Place of Public Assembly in an existing commercial building located in a B-3 (Highway Business) District. The applicants currently occupy a building in downtown Monticello on Block 52, which is under consideration for a mixed -use redevelopment project. The City's EDA has acquired the site and building used by the applicants, requiring that the EDA find a reasonable relocation site. The proposed site is vacant office/commercial space in a building at 4071 Chelsea Road, a fully - developed property with a multi -tenant commercial building and parking lot. The applicants are hoping to occupy the facility for a limited period of time, during which they plan to construct a dedicated church facility on land they own elsewhere. Because that project will require time and additional funding, their needs in the shorter term include both worship and office space on an interim basis. They propose to lease the space subject to this application package for that period. Conditional Use Permit Places of Public Assembly are currently allowed in various districts of the city, under the following standards, regardless of location or zoning district: 1. Institutions on parcels exceeding 20,000 square feet in area shall be located with direct frontage on, and access to, a collector or arterial street. 2. The buildings are set back from adjoining residential districts a distance no less than double the adjoining residential setback. 3. When abutting a residential use in a residential use district, the property shall be screened with an aesthetic buffer (Table 4-2, Buffer Type "B") in accordance with Section 4.1(G) of the Ordinance. 4. Adequate off-street parking and access is provided on the site or on lots directly abutting or directly across a public street or alley to the principal use in compliance with Section 4.8 of this ordinance and that such parking is adequately screened and landscaped from surrounding and abutting residential uses in compliance with Section 4.1(F) of the Ordinance. Planning Commission Agenda — 02/22/2022 5. Adequate off-street loading and service entrances are considered and satisfactorily provided. The B-3 District was amended in 2015 to accommodate Places of Public Assembly, but with additional criteria not common to other Districts. The reasons behind the additional criteria were to ensure that the uses in the B-3, mostly clustered around the freeway interchange and major highways, was preserved for commercial uses that relied on the traffic and exposure that those parcels provided. The B-3 district includes the following purpose statement: The purpose of the "B-3" (Highway Business) district is to provide for limited commercial and service activities and provide for and limit the establishment of motor vehicle oriented or dependent commercial and service activities. Church development has changed over time to include older models in which churches were commonly embedded in residential areas, as well as larger congregations seeking large buildings and prominent high-visibility/high-access sites. The City developed its regulations specific to the B-3 District to accommodate these larger models. The following criteria were added for consideration when looking at a CUP for a church in the B-3 district: 1. Public Assembly in the B-3 is only allowed on properties of 10 acres in size or more. 2. Public Assembly uses in the B-3 must occupy buildings of at least 20,000 gross square feet of area. 3. Public Assembly uses in the B-3 District shall provide off-street parking areas that are designed to meet their unique traffic patterns and parking accumulation ratios. For the B-3 District, the recommended requirement would be one parking space per 2.5 seats in the main assembly area, based on the building code calculation for maximum occupancy. 4. Public Assembly in the B-3 District will be required to provide a traffic study demonstrating peak traffic periods, and the ability to manage traffic loads without negatively impacting the adjoining public streets. Private and/or public street improvements may be required to ensure no negative impacts. 5. CUP applications for Public Assembly use in the B-3 District will require the identification of the principal use, and those other uses of the subject property that are proposed as accessory uses. All such uses must be allowed in the B-3 District, and may impact other support activities such as parking supply. Planning Commission Agenda — 02/22/2022 The proposal currently before the City reflects a new model - a modest -sized congregation seeking to locate in portions of existing buildings that share commercial orientation, rather than local residential settings. The Alive Church is seeking this CUP as the result of a relocation issue noted previously, moving from its current downtown location due to a pending redevelopment project in which the City is participating. As such, finding a suitable relocation site incorporates the need to meet relocation requirements of the relocated facility, which in this case, includes a site that has some commercial exposure. The proposed site meets the general objective but is insufficient in a few of the dimensional aspects required in the B-3 District, notably the lot site requirement of 10 acres. The subject property is just under 8 acres in total, and a variance is being requested to depart from the 10-acre standard. Variancp In considering variances from the zoning ordinance standards, the City is required to find that a unique condition of the property in question exists which creates a practical difficulty in putting the property to what would otherwise be considered a reasonable use. The conditions may not be created by the owner/applicant, nor may the conditions be solely economic in nature. In this case, the unique aspect relates to two factors: (1) the City's participation in the relocation need, and (2) the character of the location (both existing site and proposed site). Because the City is bound to find a comparable location when relocating tenants due to an economic development project, the commercial nature of the relocation is a key component. Moreover, the church will occupy only a small portion of the existing building, which otherwise constitutes a complete build -out of the existing parcel, and the applicant church was not involved in creating those conditions. To accommodate the unique demands of the City's relocation project, the proposed site (despite its being on a lot smaller than the B-3 requirements), would appear to be a reasonable use of the property. This is particularly so in light of two other factors. The church use of the building would constitute less than 2,000 square feet of a 35,000+ square foot commercial building. Moreover, the church use is planned to be temporary, as the congregation hopes to eventually move to a new facility built on land that they own elsewhere in the region. And finally, the church use is not expected to interfere with the other commercial uses in the building, which are dominated by daytime -weekday uses. 0 Planning Commission Agenda — 02/22/2022 The church itself has a relatively small congregation at Sunday morning services, with limited weekday activities, including occasional office hours and evening small group options. The space they occupy would be, according to building code capacity limitations, be capable of holding up to 55 people in an assembly area of approximately 800 square feet (approximately 1,000 square feet of area in the lease space is devoted to office, mechanicals, hallway, restroom, and other non -assembly use). Thus, even with a funeral event during weekday hours, the parking areas available on the property would consume perhaps 30 vehicles, out of more than 150 spaces on site. Ordinance Amendment. Included with the CUP and Variance requests is consideration of an amendment to the zoning ordinance that would modify the B-3 District standards that are creating the variance issue. There are a number of optional ways to pursue an amendment, if the City wishes to do so. One would be to modify the specific standards of the existing code. Such an amendment would apply to any future user in the B-3 District (by Conditional Use Permit). The changes would need to address both the parcel size and the building size requirements of the ordinance language. A second option would be to add an interim use permit clause to temporary occupancies (such as the one proposed by this applicant), for places of assembly that can't meet the full threshold lot and building size requirements but would seek a location that is only to be utilized pending a move to a more permanent location. Such an IUP would stand in the place of both the CUP and Variance applications, allowing the City to accommodate temporary or "interim" moves, but adhering to the current standards in the B-3 District. It is noted that the current B-3 intent is to provide for auto- or traveler -related commercial uses as its primary purpose. The objective of the 10-acre standard (and the 20,000 square foot building standard), was to accommodate larger assembly uses that are similar in scope and size to other large-scale commercial uses in the B-3 District. Smaller assembly uses — those more likely to attract congregations from a local (rather than regional) area are better located outside of this district, given its visibility and accessibility to freeway or highway -oriented clientele. The interim use permit is promoted by staff as a method of accommodating the current user's need, but without major overhaul of the standards. In staff's view, an Interim Use Planning Commission Agenda — 02/22/2022 Permit could be pursued as a component of the CUP application, without the need for a variance, and which acknowledges the temporary nature of the proposed occupancy. Staff's recommendations for the IUP provisions are summarized as follows: 1. The applicant for an IUP would enter into a development agreement specifying the duration of the IUP, with a time limitation. 2. The applicant would be able to demonstrate that the interim occupancy would not interfere with other commercial uses of the property, either in the nature of the use, the times of operation, or demand for services, such as parking or other impacts. 3. The IUP would expire upon the end of the specified term, or when the applicant vacates the property, and would not be transferable to another similar Public Assembly use. 4. Changes in scope or nature of the proposed use, operation, or other elements would require amendment to the IUP and the development contract, or a new IUP, depending on the change. 5. No such IUP, subsequent amendment, or reapplication may result in a duration of the subject use for more than ten (10) years of cumulative and continuous occupancy. With these conditions, the City should be able to be confident that the use will be both truly "interim" and be compatible with the other commercial uses in the area. As noted, the purpose of the B-3 District provisions is to capitalize on the nature of the area for commercial development and activity. Avoiding long term uses that are not consistent with this purpose is the essential objective of the regulations. STAFF RECOMMENDED ACTION Planning staff recommends approval of the Zoning Ordinance Amendment creating an Interim Use Permit for Places of Public Assembly on parcels of less than 10 acres in the B-3 District and granting of an Interim Use Permit (as a modification of the original CUP request) for the Alive Church, with the conditions required by the ordinance amendment. As an alternative to the ordinance amendment and IUP, the Commission may wish to approve the Conditional Use Permit and Variance. In either alternative, staff suggests that the Planning Commission act on the variance to the current B-3 regulations, with the understanding that the CUP/IUP and Ordinance Amendment requests will go forward to the City Council at the next Council meeting (February 28). Should the Commission and Council prefer the CUP and Variance option, the ordinance amendment would not be necessary. A recommendation by the Commission should therefore also be provided on the ordinance amendment to allow for this discussion by Council. 0 Planning Commission Agenda — 02/22/2022 Finally, because the ultimate form of this application evolved through the analysis (due to both the discovery of the lot size issue and the form of permit), the original public hearing notice did not include discussion of the variance or the zoning ordinance amendment. The notice was subsequently updated to include all three applications (CUP/IUP, variance, and Amendment). However, due to timing, the required 10 days of publication were not met. As such, staff requests that the Planning Commission refrain from closing the public hearing(s), take action on each of the requests, and then continue the hearings to the City Council as a part of its deliberations on 2/28/22. This will ensure that interested members of the public will have the opportunity to comment on the items while they are still open applications, and before the Council takes final action. The variance aspect of this request is unique in this regard. The Planning Commission, acting as the Board of Adjustments, takes "final" action on the variance portion of the request. However, an appeal opportunity exists, so City Council retains final authority over the issue. By taking action, but keeping the hearing open, the Planning Commission/Board of Adjustments acknowledges that additional public comment may impact the Council's consideration of the item. Variance action notwithstanding, staff's recommendation for the Interim Use Permit proposal would ultimately remove the need for the variance. ALTERNATIVE ACTIONS Decision 1: Consideration of an Amendment to the Zoning Ordinance regulating the requirements for lot and building size for places of public assembly in the B-3, Highway Business District, through an Interim Use Permit. 1. Motion to adopt Resolution No. PC 2022-07 recommending amendment to the Monticello Zoning Ordinance regulating the requirements for lot and building size for places of public assembly in the B-3 (Highway Business District) through an Interim Use Permit, based on findings in said resolution, and to continue the public hearing to the City Council meeting of February 281", 2022 at 6:30 PM. 2. Motion to deny the adoption of Resolution No. PC 2022-07 recommending amendment to the Monticello Zoning Ordinance regulating the requirements for lot and building size for places of public assembly in the B-3 (Highway Business District) through an Interim Use Permit, based on findings to be made by the Planning Commission, and to continue the public hearing to the City Council meeting of February 281", 2022 at 6:30 PM. 3. Motion to table action on Resolution No. 2022-07. 7 Planning Commission Agenda — 02/22/2022 Decision 2: Consideration of an Interim Use Permit (or Conditional Use Permit) for a place of public assembly in the B-3, Highway Business District. 1. Motion to adopt Resolution No. PC 2022-08 recommending approval of an Interim Use Permit (or Conditional Use Permit) for a place of public assembly in the B-3 (Highway Business District) based on findings in said resolution and subject to conditions in Exhibit Z, and to continue the public hearing to the City Council meeting of February 281", 2022 at 6:30 PM. 2. Motion to deny the adoption of Resolution No. PC 2022-08 recommending approval of an Interim Use Permit (or Conditional Use Permit) for a place of public assembly in the B-3 (Highway Business District) based on findings to be made by the Planning Commission, and to continue the public hearing to the City Council meeting of February 281h 2022 at 6:30 PM. 3. Motion to table action on Resolution No. 2022-08. Decision 3: Consideration of a Variance to the 10-acre lot size requirement for a place of public assembly in a B-3, Highway Business District. 1. Motion to adopt Resolution No. PC 2022-09 approving a Variance to the 10-acre lot size requirement for a place of public assembly in a B-3, Highway Business District, based on findings in said resolution, and to continue the public hearing to the City Council meeting of February 281", 2022 at 6:30 PM. 2. Motion to deny the adoption of Resolution No. PC 2022-09 approving a Variance to the 10-acre lot size requirement for a place of public assembly in a B-3, Highway Business District, based on findings to be made by the Planning Commission, and to continue the public hearing to the City Council meeting of February 281", 2022 at 6:30 PM. 3. Motion to table action on Resolution No. 2022-09. SUPPORTING DATA A. Resolution PC-2022-07 — Ordinance Amendment B. Resolution PC-2022-08 — Interim Use Permit C. Resolution PC-2022-09 -Variance D. DRAFT Ordinance No. XXX E. Applicant Narrative F. Site Plans G. Commercial Building Hours of Operation Z. Conditions of Approval 0 Planning Commission Agenda — 02/22/2022 EXHIBIT Z Conditions of Approval Alive! Lutheran Church, Place of Public Assembly Lot 1, Block 1 Groveland Center 1. The applicant enters into a development agreement specifying the duration of the IUP, with a time limitation. Staff and applicant suggest an initial term of four (4) years. 2. The applicant continues to demonstrate that the interim occupancy will not interfere with other commercial uses of the property, either in the nature of the use, the times of operation, or demand for services, such as parking or other impacts. 3. The IUP shall expire upon the end of the specified term, or when the applicant vacates the property (whichever is sooner), and shall not be transferable to another similar Public Assembly use. 4. Changes in scope or nature of the proposed use, operation, or other elements shall require amendment to the IUP and the development contract, or a new IUP, depending on the change. 5. Any additional recommendations of other Staff or Planning Commission. CITY OF MONTICELLO WRIGHT COUNTY, MINNESOTA RESOLUTION NO. PC-2022-07 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF MONTICELLO RECOMMENDING ADOPTION OF AN AMENDMENT TO THE MONTICELLO ZONING ORDINANCE ESTABLISHING AN INTERIM USE PERMIT FOR PLACES OF PUBLIC ASSEMBLY ON A PARCEL OF LESS THAN 10 ACRES IN THE B-3, HIGHWAY BUSINESS DISTRICT. WHEREAS, the applicant is proposing to occupy leased space in a commercial building for a Place of Public Assembly, on a temporary basis; and WHEREAS, the subject property is less than the required 10 acres for Places of Public Assembly in the B-3 District; and WHEREAS, occupancies for such uses may be consistent with the conditions found in the areas, if regulated by Interim Use Permit; and WHEREAS, an amendment to the Zoning Ordinance is proposed which would establish such an Interim Use Permit, with general conditions and an opportunity for the City to manage the location, hours, intensity, and scope of the use on parcels of less than 10 acres; and WHEREAS, the proposed ordinance amendment, subject to the comments and requirements identified in Exhibit Z of the applicable staff report February 22, 2022, along with the language as proposed in the draft ordinance, are consistent with the intent for the Interim Use requirements and the City's land use objectives for the site; and WHEREAS, the ordinance amendment would be consistent with the City's Comprehensive Plan in ensuring the continued dominant use of the site as Regional Commercial; and WHEREAS, the Planning Commission held a public hearing to consider the matter at its regular meeting on February 22, 2022 and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello makes the following Findings of Fact in relation to the recommendation of approval of the proposed ordinance, pursuant to the conditions identified by staff and others: 1. The proposed Interim Use Permit zoning amendment is consistent with the intent of the Monticello Comprehensive Plan. 2. The proposed IUP process will meet the requirements and intent of the Monticello Zoning Ordinance. 3. The proposed IUP process, when managed consistent with the terms of the ordinance, will not create undue burdens on public systems, including streets and utilities. 4. The proposed IUP amendment will not create substantial impacts, visual or otherwise, on neighboring land uses, other than temporary impacts common to the developed land. 5. The proposed amendment is found to be consistent with the proposed and planned land uses in the area. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota that the proposed amendment to the B-3 Zoning District establishing Places of Public Assembly on parcels of less than 10 acres by Interim Use Permit is hereby recommended for approval. ADOPTED this 22"d day of February, 2022, by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION Paul Konsor, Chair ATTEST: Angela Schumann, Community Development Director 2 CITY OF MONTICELLO WRIGHT COUNTY, MINNESOTA RESOLUTION NO. PC-2022-08 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF MONTICELLO RECOMMENDING APPROVAL OF AN INTERIM USE PERMIT FOR PLACE OF PUBLIC ASSEMBLY ON A PARCEL OF LESS THAN 10 ACRES IN THE B-3, HIGHWAY BUSINESS DISTRICT. PROPERTY ADDRESS: 4071 CHELSEA ROAD WEST, MONTICELLO, MN 55362 PID: 155141001010 WHEREAS, the applicant is proposing to occupy leased space in a commercial building, on a temporary basis; and WHEREAS, the subject property is less than the required 10 acres for Places of Public Assembly in the B-3 District; and WHEREAS, the proposed use is allowed through an Interim Use Permit; and WHEREAS, the proposed use and site improvements, subject to the conditions identified in Exhibit Z of the applicable staff report February 22, 2022, are consistent with the intent for the Interim Use requirements and the City's land use objectives for the site; and WHEREAS, the use would be consistent with the City's Comprehensive Plan in supporting the continued use of the site as Regional Commercial; and WHEREAS, the nature of the proposed use will have limited impacts on the dominant commercial uses of the site; and WHEREAS, the Interim Use Permit allows the applicants an opportunity to seek other permanent locations for their space, consistent with the long-term land use needs applicable to such space; and WHEREAS, the Planning Commission held a public hearing to consider the matter at its regular meeting on February 22, 2022 and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello makes the following Findings of Fact in relation to the recommendation of approval, pursuant to the conditions identified by staff and others: 1. The proposed Interim Use is consistent with the intent of the Monticello Comprehensive Plan. 2. The proposed use will meet the requirements of the Monticello Zoning Ordinance. 3. The proposed use will not create undue burdens on public systems, including streets and utilities. 4. The proposed use will not create substantial impacts, visual or otherwise, on neighboring land uses, other than temporary impacts common to to the developed land. 5. The proposed use is found to be consistent with the proposed and planned land uses in the area. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota that the proposed Interim Use Permit is hereby recommended for approval, with the following conditions: 1. The applicant enters into a development agreement specifying the duration of the IUP, with a time limitation. Staff and applicant suggest an initial term of four (4) years. 2. The applicant continues to demonstrate that the interim occupancy will not interfere with other commercial uses of the property, either in the nature of the use, the times of operation, or demand for services, such as parking or other impacts. 3. The IUP shall expire upon the end of the specified term, or when the applicant vacates the property (whichever is sooner), and shall not be transferable to another similar Public Assembly use. 4. Changes in scope or nature of the proposed use, operation, or other elements shall require amendment to the IUP and the development contract, or a new IUP, depending on the change. 5. Any additional recommendations of other Staff or Planning Commission. ADOPTED this 22" d day of February, 2022, by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION 2 Paul Konsor, Chair ATTEST: Angela Schumann, Community Development Director CITY OF MONTICELLO WRIGHT COUNTY, MINNESOTA PLANNING COMMISSION RESOLUTION NO. PC-2022-09 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF MONTICELLO APPROVING A VARIANCE TO THE 10 ACRE REQUIREMENT FOR PLACES OF PUBLIC ASSEMBLY IN THE B-3, HIGHWAY BUSINESS DISTRICT PROPERTY ADDRESS: 4071 CHELSEA ROAD WEST, MONTICELLO, MN 55362 PID:155141001010 WHEREAS, the applicant is requesting a variance to the 10 acre lot size requirements Places of Public Assembly in the B-3, Highway Business District to occupy a portion of a multi -tenant commercial building; and WHEREAS, the zoning ordinance currently requires, subject to potential amendment, a minimum lot size for such uses in the B-3 District; and WHEREAS, the proposed structure is located on an existing parcel of record, which is fully developed and is just under 8 total acres in area; and WHEREAS, the applicant is seeking the location as a result of the City's redevelopment project removing its current downtown Monticello location; and WHEREAS, the proposed use will occupy less than 10% of the proposed commercial building site area; and WHEREAS, the applicant indicates that the occupancy is for a limited time; and WHEREAS, the applicant's use is not expected to create negative impacts or interference with the other commercial uses of the property due to size, hours of operation, and other factors; and WHEREAS, the Planning Commission held a public hearing on February 22, 2022 on the application and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello makes the following Findings of Fact in relation to the approval of the variance: 1. The applicant has demonstrated practical difficulties in using the property in a reasonable manner, due to the previously existing lot and structure, all of which combine to limit reasonable construction in other configurations. 2. The existing parcel is of otherwise sufficient size and area to accommodate the proposed use. 3. The applicant is required to move pursuant to a City -initiated redevelopment project at their current location. 4. The proposed addition will not be inconsistent with area uses, nor create interference due to size and hours/days of operation. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota, that the requested variance is approved based on the conditions provided in Exhibit Z of the referenced staff planning report, as follows: The applicant enters into a development agreement specifying the duration of the IUP, with a time limitation. Staff and applicant suggest an initial term of four (4) years. 2. The applicant continues to demonstrate that the interim occupancy will not interfere with other commercial uses of the property, either in the nature of the use, the times of operation, or demand for services, such as parking or other impacts. 3. The IUP shall expire upon the end of the specified term, or when the applicant vacates the property (whichever is sooner), and shall not be transferable to another similar Public Assembly use. 4. Changes in scope or nature of the proposed use, operation, or other elements shall require amendment to the IUP and the development contract, or a new IUP, depending on the change. 5. Any additional recommendations of other Staff or Planning Commission. ADOPTED this 22" d day of February, 2022, by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION Paul Konsor, Chair ATTEST: Angela Schumann, Community Development Director ORDINANCE NO. - AN ORDINANCE AMENDING THE MONTICELLO CITY CODE ADDING PROVISIONS FOR INTERIM USE PERMIT PLACED OF PUBLIC ASSEMBLY ON CERTAIN PARCELS IN THE B-3, HIGHWAY BUSINESS ZONING DISTRICT THE CITY COUNCIL OF THE CITY OF MONTICELLO ORDAINS: SECTION 1. Table 5-1, Uses by District is hereby amended to add Places of Public Assembly on parcels under 10 acres as an Interim Use Permit to the B-3, Highway Business District. SECTION 2. Section 5.2 (D)(6)(f)(i) is hereby amended to read as follows: (f) Public Assembly in the B-3 District: (i) Shall only be allowed on properties of 10 acres in size or more, except that the City may consider such uses on smaller properties by Interim Use Permit, subject to the following requirements: a. The applicant for an IUP would enter into a development agreement specifying the duration of the IUP, with a time limitation. b. The applicant would be able to demonstrate that the interim occupancy would not interfere with other commercial uses of the property, either in the nature of the use, the times of operation, or demand for services, such as parking or other impacts. c. The IUP would expire upon the end of the specified term, or when the applicant vacates the property, and would not be transferable to another similar Public Assembly use. d. Changes in scope or nature of the proposed use, operation, or other elements would require amendment to the IUP and the development contract, or a new IUP, depending on the change. e. No such IUP, subsequent amendment, or reapplication may result in a duration of the subject use for more than ten (10) years of cumulative and continuous occupancy. SECTION 3. The City Clerk is hereby directed to make the changes required by this Ordinance as part of the Official Monticello City Code, Title 10, Zoning Ordinance, and to renumber the tables and chapters accordingly as necessary to provide the intended effect of this Ordinance. The City Clerk is further directed to make necessary corrections to any internal citations that result from said renumbering process, provided that such changes retain the purpose and intent of the Zoning Ordinance as has been adopted. SECTION 4. This ordinance shall have full force and effect upon its passage and publication. Passed by the City Council of the City of Monticello Wright County, Minnesota, this day of , 2022 Lloyd Hilgart, Mayor ATTEST: Angela Schumann, Community Development Director 2/3/22, 12:36 PM TDS WebmaiL Compose Subject: Description of operation We are a church that has been in Monticello since 2006. At the present time we are at 121 W Broadway. We have rented from Mr. Johnson for the last about 10 years. December of 2020 we were told that Mr. Johnson sold the property to the City of Monticello for redevelopment. We were then told by the City of Monticello in November, 2021 that we needed to relocate by May 15, 2022. We did purchase a parcel of land across the river in 2016 to build a new church. As of right now we do not have enough money or people to build on our land. We would like to sign a two year lease with LSW Properties. The reason that we picked this property is because it is in a location that we feel we will be more visible to the community. We may find in the area that there are people looking for a church to attend. We would be meeting on Sunday mornings for worship service at 8:15. We would be using the building until about 10:30 on Sundays. Since covid we have about 20 people that have returned to In Person Worship and about 10 people are watching our Live Stream Service. Our Office would be open on Mondays and Fridays. On the 2nd Monday each month we have our Council meeting at 6pm. In the future we may have a bible study on a Monday or Friday but not at the present time. There is a possibility of midweek services during Lent and Advent. There is always a chance of a funeral anytime. We will be putting signage on the Groveland Center board. We are also are looking at putting signage or banners in the window to the left of the front entrance of 4041. 1/1 https://mai12_tds.net/mai1#3 Engineering • Planning Surveying SEA Z DETAILS — SEE DETAIL SHEETS FOR THE FOLLOWING DETAILS 1 A 90 DEGREE PARKING SPACE STRIPING AT 9.0'* 1C HANDICAP PARKING SPACE AND SIGN (TYP,) 1 D "VAN ACC£SS13LE" HANDICAP PARKING SPACE AND SIGN 1 E PARALLEL PARKING SPACE STRIPING 2 TRAFFIC FLOW ARROW (TYP.) 3C "STOP" SIGN AND STOP BAR DETAIL 3E H "NO PARKING FIRE LANE" SIGN 3H ISLAND SIGN (134-7) & REFLECTOR (X 4-2) 31 "BEGIN ONE WAY" SIGN 3J "DO NOT ENTER" SIGN 3K "INCOMING TRAFFIC DOES NOT STOP" SIGN 4 CONCRETE DRIVEWAY ENTRANCE 5 CONCRETE PEDESTRIAN RAMP — (SEE ARCH. PLANS) 6A MN/DOT B612 CURB & GUTTER 68 MN/DOT 6618 CURB & GUTTER 9 GUARD POST (SEE ARCH, PLANS FOR ADDITIONAL POSTS) 10A STANDARD DUTY BITUMINOUS PAVING �Jn 10B HEAVY DUTY BITUMINOUS PAVING PARKING LOT STRIPING TO BE WHITE C) 2� NOTES L 1 A 4" TRAFFIC YELLOW LANE STRIPE (TYP.) 16 4" TRAFFIC WHITE LANE STRIPE (TYP) IC DOUBLE 4" TRAFFIC YELLOW LANE STRIPE (TYP) 1 D YELLOW CROSSWALK STRIPING 1 E 4" YELLOW TRAFFIC CONTROL STRIPING (DIAGONAL AT 2' D.C.) ' 4 8' CHAINLINK FENCE W/2 STRING BARBED WIRE (SEE ARCH. PLANS) 5 SLIDING GATE (SEE ARCH. PLANS) 7 RETAINING WALL (SEE ARCH. & STRUCTURAL PLANS) 8 CONCRETE SIDEWALK (SEE ARCH. PLANS) 10 ONE WAY DRIVE THRU LANE' 11 TRASH ENCLOSURE. 14 PROJECT IDENTIFICATION SIGN (PYLON) 16 REMOVE EXISTING CURBING IN CHELSEA ROAD WITH SAW CUT & CONSTRUCT CONCRETE ENTRANCE 17 WESTERN ELECTRIC LINE 18 DRAINAGE & UTILITY EASEMENT LINE 12 DENOTES NUMBER OF PARKING SPACES DEVELOPER: Progressive Development & Construction Co. 11915 Brockton Avenue North Osseo, MN 55369 Phone: (763) 428-4413 Attention — Shawn Weinand ENGINEERING CONSULTANT: MFRA 15050 23rd Avenue North Plymouth, MN 55447 Phone: (763) 476-6010 Attention -- Daniel Parks, P.E. INDEX OF DRAWINGS_ Drawing Title PUD - Civil Site Plan Grading & Drainage Plan Utility Plan Detail Sheet Detail Sheet Marvin Road- Plan & Profile LEGAL aSCRIPTION: OUTLOT F, GRQVELAND ADDITION, WRIGHT COUNTY, MINNESOTA. DEVELOPMENT SUMMARY SITE USE LOT AREA (ACRE) BUILDING AREA (SF)* LOT 1 BLOCK 1 3.65 AUTOMOTIVE/OFFICE 3,627 AUTO BODY 10,812 AUTOMOTIVE 3,890 MIXED USE 9,982 OUTLOT B 0.53 MIXED USE 11,330 OUTLOT A 4.69 PONDING & WETLAND TOTAL 8.87 39,641 *GROSS BUILDING SQUARE FOOTAGE (INCLUDING 2ND STORY) -- PARKING SPACES PROVIDED: 181 — INCLUDES 6 HANDICAPPED SPACES GENERAL NOTES: ALL DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULE, SLOPED PAVING, EXIT PORCHES, RAMPS, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. ALL CURB RETURN RADII ARE TO BE A MINIMUM OF TWO (2) FEET UNLESS SHOWN OR NOTED OTHERWISE. BITUMINOUS PAVEMENT SECTIONS TO BE IN ACCORDANCE WITH RECOMMENDATIONS OF SOILS ENGINEER. TRAFFIC SIGNS TO CONFORM WITH MNDOT AND CITY STANDARDS. PARKING STRIPING TO BE 4" WHITE STRIPE SEE PROPOSED PLAT FOR LOT BEARING DIMENSIONS AND AREAS 104 [il:d Irm-I McCombs Frank Roos Associates, Inc. 15030 23rd Avenue North Plymouth, Minnesota 55447 phone 76JI476-6010 fax 7631476-8532 E—Mail; m fra&n fro, cam Client Progressive Development & Construction Co. Osseo, MN Project Groveland Center Monticello, MN Sheet Title PUD - Civil Site Plan I hereby certify that this plan was prepared by me or under my direct supervision and that I orn a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signature A'LA Nome Daniel M. Parks Date License # 18919 Designed DMP Checked DMP Drawn MRJ/ATP Approved DMP Date 212 Revisions No. Date By Remarks A 4/3/02 MRJ REV. PER CLIENT B 5/1 /02 ATP REV. SITE PLAN C fi 3 02 MRD REV. PER WSB 5 30 02 LE D 6 8 02 D8 REV. MARVIN RD. CURB. Sheet Revision C1 D 6 TER 0 20 40 80 160 MFRA FILE No.: 13627 A LAVATORIES SHALL. HAVE A CLEAR ACCESS WIDTH OF NOT LESS THAN 30% CLEAR HEIGHT OF NOT LESS THAN 29" TO THE BOTTOM OF THE FIXTURE APRON, CLEAR HEIGHT OF NOT MORE 34" TO THE RIM OF THE FIXTURE, AND A CLEAR DEPTH OF NOT LESS THAN 12" UNDER THE FIXTURE EXCLUSIVE OF BOWL AND WASTE PIPE. ALL EXPOSED PIPES ARE TO BE COHERED WITH AN INSULATED PROTECTIVE MATERIAL THE WATER CONTROL VALVES SHALL HAVE LEVER HANDLES. REVROOM ACCESSORIES NOTE: MIRRORS SHALL BE MOUNTED SO THAT THE BOTTOM IS NO HIGHER THAN 40" ABOVE THE FLOOR. ALL WALL —MOUNTED DISPENSERS, WASTE DISPOSAL CONTAINERS, OR SIMILAR ACCESSORIES SHALL BE MOUNTED SO THAT WORKING HEIGHT IS NO HIGHER THAN 40" ABOVE THE FLOOR, AND SHALL BE FREE OF INTERFERENCE BY GRAB BARS OR OTHER ACCESSORIES OR FIXTURES. GRAB BARS SHALL SUPPORT A HEIGHT OF 250 LBS. OR GREATER. RESTROOM INTERIOR FINISH NOTE: FLOORS IN THE WATER CLOSET COMPARTMENTS ACCESSIBLE TO THE PUBLIC SHALL HAVE A SMOOTH, HARD NONABSORBENT SURFACE SUCH AS CERAMIC TILE AND SHALL EXTEND UP THE WALLS AT LEAST V. (IBC 1209.1 WALLS WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. (IBC 1209.2) 12" MAX 42" A7 r� GENERAL NOTES: 1. TENANT BUILD OUTS WILL BE SUBMITTED UNDER A SEPARATE PERMIT. 2. AREAS -- 1O1 — 1,935 S.P. 105 — 280 S.F. 109 — 119 S.F. 102 — 1,817 S.F. 106 — 55 S.F. 110 — 65 S.F. 103 — 1,833 S.F. 107 — 48 S.F. 111 — 65 S.F. 104 — 3,363 S.F. 108 — 55 S.F. 112 — 48 S.F. r �I PR01ECTiVE F �_ i_ 2 COATING OR 2 r� ' COVER FOR ^ ¢ F PIPING � cv V) BACK WALL SIDE WALL 8fXMIN. 6" MAX. TOE CLEARANCE) NEr CLEARANCE 17 MIN, 19" MAX. GRAB BARS AT ACCESSIBLE WATER CLOSETS LAVATORY CLEARANCES 2 RESTROOM DETAILS & NOTES I H1 SCALE: 3 8 = 1 —O F n R r n n r r n 11 a I I A KI r C � 30"x48" CLEAR FLOOR I PACE 30"x48 CLEAR FLOOR SPACE j' .O.10 C4 18" 42" MIN. 18" 7'-4" NOTE: 27" - WALL MOUNTED TOILET 31" = FLOOR MOUNTED TOILET ENLARGED RESTROOM PLAN 6j!'j'/ SCALE: 3/8" - 1'--0 1 HOUR V METAL STUD WALL One Layer $/8" Type 'X' Gypsum Wallboard Or Gypsum Veneer Base Apelied At Right Angles Or Parallel To Each Side Of 6" Steel Studs 24 o.c. With 1" Type S Drywall Screws 8" o.c. To Vertical Joints And 12" o.c. At Floor And Ceiling Runners And Intermediate Studs. Stagger Joints Staggered 24" On Opposite Sides. GA FlLE NO. WP 1200 STC RATING - 40-44 6" STUDS ALLOWED TO BE SUBSTITUTED I`OR 3-5 S" STUDS 4 1 HOUR DEMISING WALL I H1 I SCALE: -V 0 GENERAL INFORMATION A. PROJECT NAME: Leoseholds For Groveland Center B. PROJECT LOCATION: Monticello, Minnesota APPLICABLE CODES: COMMERCIAL P LA N R E V I E W A. INTERNATIONAL BUILDING; CODE 2DDO Edition 9. MONITICELLO ZONING ORONANCE Current Edition C. MINNESOTA STATE BUILD G CODE 2003 Edition O. MHO PLUMBING CODE 2003 Edition E. MINNESOTA ELECTRICAL Ot]E (NEC) 2001 Edition F. INTERNATIONAL ENERGY ONSERVA110N CODE 20M Edition G. INTERNATIONAL FIRE. CODE 2000 Edition H. UMFORM MECHANICAL CME 1997 Edition J. MSBC, CHAPTER 1341 — ACCESSIBILITY 2003 Edition AUTOMA11C SPRINKLER i REQUIREMENTS A. AN EXISTING NFPA 13 A1lTOMATTC SPRINKLER SYSTEM IS PROVIDED THROUGHOUT THE BUILDNG (IBC 903.3.1.1) EXITING A. EXITS 1. Number Required (I 1004'2.1) 1 2. Number Accessible R uired (IBC 1003.2.13) 1 3. Arrangement (IBC 1 ,2.2) — Not Less Than 1 / Overall Diagonal (Sprinklered Building) 4. Travel Distance Maxl ms — Exit Access (IBC 1 4.2.4 = 300' — Common Path of a" IBC 1004.2.5) 100' — Single Exit Build In (IBC 005,2.2) 75' 5. Width — Stairways (IBC € 3.3.1 = 36" — Corridors (IBC 1 3.2.2 = 36" — Exit Possageway9 C 1 5.3.3) 36" — Exit Doors (IBC 1 5.3.3) = 32" Min Clear 48" Max Nom 6. Doors — Swing (IBC 1003.3 .2) Side Hinged Swingg Out At Occupant Load Greater Than 49 — Landings (IBC 1 a0 3.1.5) Width Not Less T Width of Door Length in Dlrecti of Travel Not Less Than 44" r- Thresholds (IBC 1 Max Height = 1 / -- 1: 2 Beveled Edge If 1/4"-1/2' -- Consecutive Doors IBC 1003.3.1,7) 48 + Door Width Apart — Lock or Latch 18 1003.3.1.8} Operable From Ins Without Use of Knowledge or Keys. Manually Operated ush Bolts or Surface Bolts Are Prohibited. — Fire Exit Hardwar IBC 1003.3.1.9) Not Required At itAccess Doors OTHER A. ACCESSIBILITY (MSBC 1 1) 1. Building is Acceasibl B. SAFETY GLAZING (IBC ) 1. Safety Glazing Shall Installed In Hazardous Locations As Specified In IBC 24 2 17"-19" HIGH FOUNTAIN HIGH FOUNTAIN EQUIPMENT LOW FOUNTAIN PERMITTED IN SHADED 4- AREA Z Q 130"x48" e PROTECTIVE = C4 CLEAR COATING OR o, ^ SPACE COVER FOR J N E UIPMENT 8" MIN.J L 6" MIN. SPOUT HEIGHT AND KNEE CLEARANCE FOUNTAIN DR COOLER KS�DRINKING FOUNTAIN DETAILS & NOTES I W11 SCALE: 3/8" - 1'-0 TOTAL — 9,683 S.F. _ v I _ 1 I to 00 * = TEMPERED GLASS Z E R O ANODIZED HOLLOW METAL. ALUMINUM @ W/ 2 COATS OF PAINT DOOR TYPES NOT To SCALE 4'-4" 3'-4" _70 2" 10" 3'-0" 2" 2" 3'-0" 2" 2N ■ R I iV cv p iV F1 ANODIZED HOLLOW LAL ALUMINUM / 2 COATS OF PAINT FRAME TYPES �Ieii>[*TlF�eli>�a EXISTING DOOR 'J �. 1 fo �x Ic 34'— Q" 8" 7'irVv1j 110 �1 s -17� l t4ye -- V aC'an�- 44'-7" LEASE A '2, 1O2 1,817 S.F. I� v �nI r HATCH INDICATES - WALL TO ROOF DECK EXISTiN 1 °' DOOR 34'-0" tea, ,,j, �-, ""'i ��y--K-..-.k,�-�. sy ..•,; --�� f 4 T ark 7I!'�. i " , 20 —fi 53 —4R - 107 10 1tr}Sl'2jej I r' -^ r�•� DOORS t11><'t1 �,'' S W' J 0 $ s o ­J -'' EXISTING , F`' TRASH r ENCLOSURE ` . . . Q I I I I I 1 l 1 —O " I I ! I I kI',� 1d of I EXISTING I I EXISTING I I EXISTING I P tIm J;V10 . OVERHEAD k� OVERHEAD OVERHEAD ?i X Ot I I IYOOR i DOOR f DOOR L EXISTING ' 47'-11 1/2" - SHIPS---LI1)96 I ~ ' • " - COP IOR --� EXISTING 4 FLOOR DRAIN LEASE A , 3' H TYP. 1 03 11 1,833 S.F. DR114KING Id— 73 FOL SEE N TAIN 5/LH1 1 S� 102 103 = o �.,�.. v MEN 108 106 OMEN E I OM ' 108 1 D6 0 101 4 104 � H r J R 107 107 F- ifl — 1 — •I 4'— 4" 4'-6 1/2 1 } LEASE AREA '1' 101 1,935 S.F. C 0( � I 4'-1 1/2", 11'-5 1/2* LEASE AREA $ 4' I 3,363 S.F. I co u3 Cc, Kc I 5-1 1 /2" 52'--C 1/2" I C*4 fVEVC 10 LE 100 -- EXISTING DOOR 74'-10" NORTH FLOOR PLAN LH1 SCALE: 1 8 = 1 —0 ROOM FINISH SCHEDULE RM# DESCRIPTION FLOOR BASE N.WALL EWALL S.WALL W WALL CLa HGHT REMARKS 100 VESTIBULE C.T. C.T. PT GYP PT GYP PT GYP PT GYP A.C.T. 9 —0 FURR SOUTH WALL 101 LEASE AREA '1' SLD. CONC. --- GYP. GYP. --- -- --- 102 LEASE AREA '2' SLD. CONC. --- --- GYP. GYP. ---- --- --- 103 LEASE AREA '3' SLD. CONC. --- --- GYP. GYP. GYP. --- --- 104 LEASE AREA '4' SLD. CONC. --- GYP. --- --- GYP. --- ---- 105 CORRIDOR VINYL VINYL PT GYP PT GYP PT GYP PT GYP A.C.T. 9'-0" 1 HOUR RATED CORRIDOR 106 WOMENS RESTROOM C.T. C.T. PT GYP PT GYP PT/GYP PT GYP GYP. 9'-0" 4'-0" HIGH C.T. WAINSCOT 107 JANITOR SLD. CONC. --- GYP. GYP. GYP. GYP. --- --- 108 MENS RESTROOM C.T. C.T. PT GYP PT GYPfT JGYP PT/GYP GYP. —0 4'-0" HIGH C.T. WAINSCOT 109 HALL V T GYP PT GYP A.C.T. 9'—O" 110 WOMENS RESTROOM C.T. C.T. PT GYP PT GYP PT GYP PT GYP GYP. 9 —0 4'-0" HIGH C.T. WAINSCOT 111 MENS RESTROOM C.T. C.T, PT GYP PT GYP PT GYP PT CYP GYP, 9 —O 4'—O" HIGH C.T. WAINSCOT 112 JANITOR SLD. CONC. --- GYP. --- GYP. GYP. I--- --- EXISTING MECH ROOM I� +ti 1 I t L ,9 5' 5" 0 110 G1101111111111111111 F r C� d# LL 4nQ Cc F.D1DRINKING---FOUNTAIN E 5£E 5/LH1 111 C 11L 'i09 I r- 1 4 EXISTING DOOR 6'-9 1/2" WOMEN RESTROOM 11� MEN RESTROOM 111 apt —JANITOR 112 Fu..— V -. . - AlATEKSACS �..� m U J T B ew I (' r )a �J �] r 'y APPROVED JOB COPY IiEViEWEO FOR ippE COMPLIANCE • SUPUECT ra NILD INSPECTION Signature: DOOR do FRAME SCHEDULE .. DR / DOOR SIZE THICK DOOR FRAME REMARKS 1 OOA 3 —0 x7'—O 1 3 4 A F1 INSULAT€NG GLASS 100E 3'-0"x7'—O 1 3 4" A F1 INSULATING GLASS 101 3'—O"x7'-0" 1 3 4" B F2 20 MINUTE RATED tO2 3'--0"x7'—O" 1 3 4" B F2 20 MINUTE RATED 103 3'-0"x7'—O 1 3 4" B F2 20 MINUTE RATED 104 3'—O"x7'—O 1 3 4" B F2 20 MINUTE RATED 106 3—0"x7'-0" 1 3 4" B F2 20 MINUTE RATED 107 3'-0"x7'—O 1 3 4" B F2 20 MINUTE RATED 108 3'-0"x7'—O" 1 3 4" B F2 20 MINUTE RATED 109A 3'—O"x7'—O" 1 3 4" B F2 10913 3'-0"x7'-0 1 3 4" B F2 110 3'—O"x7'—O" 1 3 4" B F2 111 3'-07_r—_O0 1 3 4" 8 F2 112 3'—O"x7'—O" 1 3 4" B F2 L A M P E R T A R C H I T E C T S 13837 NE Lincoln Street Ham Lake, MN 55304 101 Phone! 763.755. t 211 I-ax:763.757.2849 IamperlAlamperi-arCh.car*t ARCHITECT CERTIFICATION: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. SI ,NATVRE LEONARD LAMPERT _.. . PRINT NAMF 13665 LICFNSE NO ()A lE. - Copyrlghl 2003 Leonard Larnport Archilecls, P.A. Drawn By. NJC, JRM Checked By: LL/LML Revisions FLOOR PLAN Sheet NLJmber LH1 Project No. 030729-- . r _ ! Of a I I [Y A3 j io � r tt � r � ! 0 I N 0 I 00 in I, M 11_4r 3'-4" 3'-4" 3'-40 3'-4r '—S" 14'-8" 5'-41" 14'-0" , u6'-Qi.1a'-0" fi'-0" 10'x10' 1 1 O.H.D L _ J F.D.o *F.D. p-�Iq tLE.DD,-If'r.D,11 BAY 'A' 10,515 S.F. 5]�eC+ ?O- 341-0w 308,-0" 3'-4" -8"nn 2'-p"n 2 -aL n1J�rrJ� rrpw r�.7 10'- IBYRASH COMP OTHERS TRASH T O.H.D I I O.H.D . 00 1 ❑'x8' 1 1 10'x8' I - _ J iCLOS.ETJ 110'00' I PRINK 1 O.H.❑ } F.D..D. L _ J n r: �RAI NG- = '0 'Co HALF HIGH �___ GLASS IN ELECTRICALDOOR CONDUIT, .'0 I VERIFY BAY 'B' r LOCATION 4.017 S.F. D: F.D:- ' _ '� E r BLOCK" DEMISING WALL (TYP) ..I 16' 3.1 — Aw T. MSBC 4715.1120; AN 4444c`+ OIL AND FLAMMABLE LIQUIDS SEPARATOR 106x8 SHALL BE INSTALLED AS REQUIRED HEREIN. Y VERIFY LOCATION, IDENTIFY NTH APPROPRIATE ,.8r 81-0. 8,_aw DRAINS ON PLUMBING PLANS 1 -0" 2'-$" 2'-a' 2'-Sr N ELECTRICAL CONDUIT, VERIFY LOCATION -4 2'_ w 21_0w r,- " 2._ w �_g 4r 81`-4" U 45'-4" 2 CE�.TRAL MEZZANINE PLAN A2 SCA6 =1 -0 ]OR TO HAVE kNIC HARDWARE / ALARM. r 1'-8 1/2" " 40 1 4R� 2'-0 ,T4.�2'-Ow 2'-0/�j' 21 C" on2'-0"15'-7 1/2" as a 4'-OE'-S" 10'-0" 11'-4" .+" 1 r 1 /:1 C1" 1 OI _ i.i" 1 O' — 0 r Yy s dD 11`Lrdlfl I ELEC. ELEC. -_-_ I _4 TRASH = 1MNp�_ 112'x12' }H 10'x12' I A W O:H.D } O.H.D IN DOOR I l ELECTRICAL r = L _ - - M � EL CAL PANEL 4 O.H.D 0 EYE WASH F.D. , - ! v� CO DU + 110'x8' o = STATION VE IFY[�OCA-tn.,4-5 ��+G� L_- _ N F.D.�D- ! K1/2 BRADLEY 1 1.H.D a EQUIPMENT ' _ ! COLD BY OTHERS F.D. it BAY 'E' } 10'x$' 11 -8 1/2� 1,776 S.F. L_ - 12Fwx12'r WINDOW ,F.D,1� OFFICE IN DOOR '� C FUTURE HOTTOLD •F.D.1I 110'x8' 0 1:4 BOTTLED WATER D F.D+ �_J } O.H.D -I BY OTHERS - BAY 'D' l _ _ ao 0 BAY 'C' - --- - - - - 10,722 S.F. r F.D. 1,918 S.F. I In - = -erp r } O.H.D �- _ 11O'x8' 0 N EQUIPMENT CO D BY OTHERS ELECTRICALr-OLD - - f - F.D,:. FUTURE FUTURE D.H.D o iv --HALF HIGH OFFICE } I O'x8' b SWINGING DOOR IFLAMABLE L- - I -- - - - - --Fpnl WASTE TRAP 9AG *-V-]-----_" 4'-$" 3'-4" 3'-4" 4_ COLD F.Da �oa s I ' $'-0" fi'-8" 5'--0" 7'-4" 7'-4" 7'-4" 8'-0" 5'- "6'-8 8'-0" 1 8 2 - 102'- 0w 2'-8" 2'-0" `'8r .7 n 2'-8" 2'-8" 1 ,. _Vr 45'- 4" 1 A NORTH 1 FIRST FLOOR PLAN ;V0 A2 SCALE: 1 16 -1 -0 UITE 'E SUITE 'F7"�� 9 S.F 31$ S.F. I 22'_1 1 /2" 4'-9 1/2" _ 16'-11" 1 2'-9 SUITE 'D' az I 544 S.F. �- 'F.D. �R++EF. SINK - , w i � 9�- •F.D MICROWAVE SUITE 'D'`' 544 S.Fr, b� r s.� 18,-5" SUITE 'A' i1 SUITE 'B' 445 S.F. 1} 489 S.F. Co m 11 EAST MEZZANINE PLAN NORTH A2 SCALE: 1 /16"=1'-0" co NOTE; INTERCOM SYSTEM TO BE INSTALLED IN EAST MEZZANINE. BY OTHERS. 8" 0 Q R 0 I m L A M P E R T A R C H I T E C T S 13837 NE Lincoln Street W Ham Lake. MN 55304 101 Phone:763-755-1211 Fox:763.757.2849 ismper blampert-arch.com ARCHITECT CERTIFICATION: I HEREBY CERTIFY THAT THIS PUN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER My DMiIrCT SuPERMSION AND THAT I Ali A DULY LICENSED PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA - SIGNA TV PC CERTIFICATION NO. DATE Kinho 7"?rL AM'' GENERAL CONTRACTORS 14198 Norlhd010 @hd Ropes, A!N 53374 Tel: 763-428-SOM Fax: 765-428-800 W z tv p 'C Z o N J u 0 CL ULJ > 4� 0 OCL f V Drawn By. TKN Checked By: LL/LML Revisions 02.06.02 PRELIMINARY 02.22.02 REVISED PRELIM 04.22.02 REVISED PRELIM. 04.23.02 REVISED PRELIM. FLOOR PLAN Sheet Number A 2 Project No. 020125-3 Space address sq ft employees Hours business type 4041 Chelsea Road 2307 vacant 4053 Chelsea Road 2257 2 6am-3pm Rice lake Const. m-f office 4059 Chelsea Road 2725 2 6am-3pm Rick Lake Const. m-f office 4065 Chelsea Road Progressive Dev. 6am-3:30om m-f 7am-5:30PM m-f 1645 2 office body shop 4071 Chelsea Road Steele's Colision 4093 Chelsea Road 15366 8 2000 2 7:30am-5pm Enterprise m-f office 4087 Chelsea Road Suite 201 642 vacant Suite 202 649 2 6am-3pm office G&M Outdoor Suite 203 689 vacant Suite 204 689 vacant Suite 205 Monson Trucking 630 1 8am-3pm office Suite 206 Monson Trucking 401