Loading...
2022-00544CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 8818 FARMSTEAD AVE PIN 155259001070 LEGAL DESC HAVEN RIDGE LOT 007 BLOCK 001 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE DECK VALUATION 3,600.00 NOTE: 12' X 15' DECK WITH STAIRS APPLICANT FOREMOST BUILDERS INC 17917 237TH AVE BIG LAKE, MN 55309- 763) 260-4499 OWNER KUSHAL, JAIN 8818 FARMSTEAD AVE MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date 2 0 2 2- 0 0 5 4 4* DATE ISSUED: 08/01/2022 Permit #: 2022-00544 BUILDING PERMIT FEE 103.09 PLAN REVIEW 67.01 STATE SURCHARGE, BLDG VAL 1.80 TOTAL 171.90 Payment(s) CREDIT CARD 171.90 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY O F D i Permit No. Monticello J U L 2- - 202 DateABUILDINGSAFETY RESIDIs NTW, BiJILDING PE.R441T ADDITION / ALTERATION / REMODEL SITE ADDRESS ( 8 8I LEGAL DESCRIPTION LOT o ®% BLOCK O® 1 PLAT e ti PI.D. NUMBER l 5 5 25 9,no lO -7J OWNER (Name) (Address) r" 5 l 8B1 g CONTRACTOR (Name) (Address) CONTRACTOR'S LICENSE NUMBER (IF APPLICABLE) b(_- 610(013 PLUMBING BEING COMPLETED BY (PLEASE CHECK ONE): HOMEOWNER CONTRACTOR IF APPLICABLE, SPECIFY CONTRACTOR CHECK ALL THAT APPLY: TOILET SINK BAR SINK LAUNDRY TUB SOFTENER TOTAL # OF FIXTURES Lic # Tel. No.) Tel. No.) 1G32-'o4 Lj71 BATHTUB/SHOWER OTHER REMINDER: IF YOU DO NOT OWN THIS PROPERTY OR ARE NOT PERFORMING THE WORK, PERMIT MUST BE PULLED BYA MASTER PLUMBER) MECHANICAL BEING COMPLETED BY (PLEASE CHECK ONE): HOMEOWNER CONTRACTOR IF APPLICABLE, SPECIFY CONTRACTOR CHECK ALL THAT APPLY: FURNACE TOTAL # OF FIXTURES Bond # DESCRIPTION OF WORK: (Z K 1 f J(Lr_Ct ESTIMATED VALUE OF CONSTRUCTION A/C FIREPLACE BATHFAN o`er 2 s t Applicant Signature 505 Walnut Street, Suite #1 Monticello, MN 55362 Approved by Building Official: k t Date Approved: 3 - I - 2e72:Z_ fZ5-/2 Z Date Phone: 763-295-3060 Fax: 763-295-4404 A t go O , w MVg0 P3P`' 8ID VIC ate' 00 00 4, 00 HMDRAILS: Shall Be Conte, 34 to 38 Inches Above Tread Noses ROM Ends or Terminate Newel Posh m APPROVED FILE COPY REWEMD FOR CODE COMPUAMa SURIECT i0 FIEU) INS ECWN Date: 8-1-2-4 17— SIVature: J,, A rjuwd W}kw 3W M"nium Hs% t 4' Sphere gust Not Pam 00A ' c C> JuS 0-1 C ` C\ \ P®WW3®No®®i-.A®q ALL JOB DEBRIS MUST BE CONTAINED OW -SITE AND IN A DUMPSTER OR COVERED, FENCED AREA 0 ®a iQ,J LOL V )- /) - — ID 9r, V - ( -CJ-e 2- VL Stair Risers -max mum 73ia inches in height A Stair Treads 10" rninimum depth i Maximum +ariation 3/8 inch Min. landing lengti w direction of travel is 36" Provide Stairw4y IlluminaUon Close Stair Rlsetst & Below Rail: A' Sphere Must Not -ass Riser Openings V Sphere Must Not Pass Below Guard Pail L Deck Width 13eam Size: Post Size: VlPost Spacing CITY OF on ice-o BUILDING SAFETY IUX(0 m 0 A 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 Email: buildinq.department2()ci.monticello.mn.us DECK PLAN DETAILS fill in the blanks) I Joist Length: Lug, Joist Size: Joist Spacing: Please provide measurements in the blanks below): 2 X, l0 1(.0 it L,,Clumber of Posts: - HainiA Joist Cantilever V/ V oemc ZtHeightAboveGrade 3 Footing Diameter 4P 3 Bottom Diameter ; APPLICATION CHECKLIST: c1 Address: —'ec,J 4t--r_- Yes No 1. Is a future porch being considered? 2. Will there be a hot tub or spa on the deck? 3. Is the deck attached to a house cantilever? If yes, provide special design. QQ ' 4. Is a guardrail required (over 30 inches above grade)? 5. Is a handrail required on the stairs (4 or more risers)? 6. Does the deck site plan show distance to property lines and buildings? 7. Using composite deck materials? If yes, identify M-f-ti/le. 15 —rc L I WR7191N FLOORS RIM PRIMARY STRUCTURE FOR CANTILEVERED JOISTS BLOCKING OR / OTHER LATERAL LEDGER / j RESTRAINT BOARDREQUIREDOVER / MM BEAM / JOIST / JOISTS / HANGER / BEAM / POST (BEYOND) JOIST SPAN OPTIONAL CANTILEVER CANTILEVERED JOISTS WITH DROPPED BEAM RIM FOR CANTILEVERED JOISTS BLOCKING OR OTHER LATERAL RESTRAINT REQUIRED OVER BEAM I N\\' JOIST BEAM POST (BEYOND) JOIST BEAM POST (BEYOND) PRIMARY STRUCTURE LEDGER / BOARD JOISTS / HANGER / EACH END / JOIST SPAN MEASURED CENTERLINE TO CENTERLINE OF JOIST HANGERS JOISTS WITH FLUSH BEAM JOIST BEAM POST (BEYOND) JOISTS HANGER EACH END JOIST SPAN - JOIST SPAN MEASURED OPTIONAL OPT ONAL CENTERLINE TO CENTERLINE CANTILEVER CANTILEVER OF JOIST HANGERS JOISTS ON FREE-STANDING DECK JOISTS ON FREE-STANDING DECK WITH DROPPED BEAM WITH FLUSH BEAM FIGURE R507.6 TYPICAL DECK JOIST SPANS 210 2020 MINNESOTA RESIDENTIAL CODE All 111kilA Itil ig I CnpyrlgM t mzolCC ALI RIGIRSRFSERVF.D A.c Mby Dan Fleur ldan klem@ci montl.elln mnud), (-)Order Numb,,1-8719tnnn Apr z1. mznox nx AM (PDT) p—am Inl.t — Agreemem with ICC 11,1.11 ' - No further repmdu.trnn. no further repmductn.ns by uny third pany, or dtatnbution authnnzcd Single uur only, ropying and network ng prohibited ANY UNAUTI IORIZED RF.PRODUCIION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE I ICENSF. AGREEMENT. AND SUBIF.CT TO CIVIL AND CRIMINAL PF.NAI TIES THEREUNDER IOlIB7191B For SI: 1 inch = 25.4 mm. 5 z" MINIMUM FOR BEAM SPLICES BEAM SPLICE IF REQUIRED) IF REQUIRED) MUST OCCUR OVER POST APPROVED POST CAP BEAM OVER POST CAP BEAM OVER POST FIGURE R507.5.1(1) DECK BEAM TO DECK POST MINIMUM 2" MINIMUM 2'" i SINGLE PLY BEAM MULTIPLE -PLY BEAM 2)1 /2" DIAMETER THROUGH -BOLTS OR APPROVED EQUIVALENT CONNECTOR POST NOTCH FOR FULL -BEAM BEARING z 2'/z" MIN. BEAM SPLICE L 2" T y 5" Z4 21/" For SI: I inch = 25.4 mm. FIGURE R507.5.1(2) NOTCHED POST -TO -BEAM CONNECTION FLOORS 2020 MINNESOTA RESIDENTIAL CODE 209 11 i 1111 PIIM11 11 ' 1111 C. pyrlghl anzu I(:(] ALL RIGHTS RFSERVED Acc—d by Dan Klein Ida, kkr,C ci mont-11, mn us). () Order Number ui W171931- Apr z 1, zuzu ux qN AM (PDT) pursuant 1. Li.ense Agreemem —h ICC No funher reprndunCnn,„furCher repndu.unm by any Chard pany, nr dCunhuunn a h,r ,d Single uar nnly..npying and ne—kmg prohib,ed ANY UNAUTIIORIZED REPRODUCTION OR DISTRIBUTION IS A VIOIATION OF THE FEDERAL C:OPYRIGI IT ACT AND THE LICFNSF AGRF.WENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIFS TI IF.REUNDER IM871918 FLOORS NOTE: THIS DETAIL IS APPLICABLE _ WHERE FLOOR JOISTS ARE PARALLEL TO DECK JOISTS. 2" MIN. SHEATHING SIDING FLASHING FOR WATER TIGHTNESS DECKING APPROVED JOIST HANGERS 2x LEDGER WITH FASTENERS IN ACCORDANCE WITH TABLE R507.2 HOLD-DOWN DEVICE MIN 750 LB. CAPACITY FLOOR JOISTS AT 4 LOCATIONS, EVENLY DISTRIBUTED For SI: I inch = 25.4 mm, I foot = 304.8 mm ALONG DECK AND ONE WITHIN 24" OF EACH END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD-DOWN MANUFACTURER. A FULLY THREADED a/e" DIAMETER LAG SCREW PREDRILLED W/ MIN. 3" PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER. FIGURE R507.9.2(2) DECK ATTACHMENT FOR LATERAL LOADS 214 2020 MINNESOTA RESIDENTIAL CODE 11 I'1 III111NLM11111 M11111 \ "I Copy n& zozu ICC ALL RIGHTS RESERVED Accessed by Dan IQeln (dan LleinC i.munucello mn us), (-) Order Number 01mie71918- Apr 24, zoza ua as AM (PDT) pursuant to 1—w Agreement wuh ICC No further reprodutt . no further reprnd—iom by any thud party, or distrlbuuon authoraed Singlc —only, copying and noworlung prohibited ANY UNAUTHORIZED REPRODUCTION OR DISTRI LMON IS A VIOLATION OF THE FEDFRAI COPYRIGI IT ACT AND TI IE LICFNSF. AGRF.FMF.NT, AND SUBJECT TO CMI. AND CRIMINAL PENALTIES TI IERF.UNDER N Grading As -built for: CAPSTONE HOMES, INC.BE 3 5 4; House Address: 9 y 8818 Farmstead Avenue, Monticello, MN EO.F. ee ' A913WLTUkAD7G6L'RVLY 9 962.3 , A o, 24n1] 2 964 4 962 3 9611 6OrSPe / 1 ". 962 3 J / x 963 2 96 99609 J t, 4.oQ o\,yeDoo° ` ` , 6 q grO o}' J ' / \ \ ,\\ \ s 4 Ja. c °1• x 9631 oJ 9a, / 9637 x9628 964 3 O yaGa16. S/ 964 4 i0 /} o A Br / ,,, !° property Owner 4o22po0',\ pCy g6A r / \ existing, privetbr962arr°+s 9c 9 TC li` y6 2 oc8O9F30,:., v09 } o\ 9 Cyr9621 s s, 0°1° E.O.F.- 9 30 962 2 4 ' \ caTC k 9\\ 9622 CBTC E.0:0 Denotes Emergency Overflow j Denotes Existing Hydrant p Denotes Existing Telephone Box F] Denotes Existing Electric Box Denotes Existing Light Pole ® Denotes Existing Television Box o Denotes Existing Service p Denotes Existing Curb Stop x om,o Denotes Existing Elevation LEGAL DESCRIPTION: Denotes Direction of Drainage Denotes Drainage & Utility Easement Lot 7, Block 1, HAVEN RIDGE, per recorded plat) Wright County, Minnesota l + Denotes Iron Monument Bearings shown are assumed Minimum Lowest Floor Elevation: 961.7 AS -BUILT BUILDING ELEVATIONS GRAPHIC SCALE 0 15 30 60 Lowest Floor Elevation: -S&I-r N/A III Top of Foundation Elevation: —96+.Ir 965.0 Garage Slab Elevation (at door): -964,4X 964.5 IN FEET) 8.5x14 sheet) 2251 9157.007gab DPE HVR01107 CARLSON hereby certify to Capstone Homes, Inc. that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly licensed land j®® WCA 1 surveyor under the laws of the State of Minnesota. ENGYNEERING \ SURYEYING \ENVIRONMENTAL Dated this 19th day of August, 2021. Signod' *c. eg. 3890 PHEASANT RIDGE DRIVE NE BWNBMN88449 By. TEL (763) 489_7900, PAX (763) 489-7939 homa CARLSDNMCCAIN.COM Peter J. Blomauist. L.S. Rea. No. 51676 Ilcant small verify all public easements. Drill/power screwdriver • Tape measure 1/8" drill bit • Carpenter's pencil Circular saw with carbide -tip blade • Safety glasses/goggles 2 1/2" composite wood deck screws Notice to installers: DO NOT use cordless impact drivers Set drill speed to 1500-1750 RPM Max torque not to exceed 23 inch pounds Pre -drill knots or dense hardwood Prior to construction, check with your local regulatory agency for special code requirements in your area. For best results, follow these simple installation instructions, paying close attention to gapping, spacing and fastener requirements. 3er Snarinc Note: Always follow best workmanship practices. Including, but not limited to, square cutting both board ends prior to installation. Stringers spacing is a maximum of 9" on -center. Minimum of 5 stringers with 4 spans. For commercial applications, maximum of 8" on -center. Allow a minimum of 1/8" between board ends. Allow 1/4" distance between all stair tread material and any permanent structure or post. For a list of recommended and compatible fasteners please visit http://deckorators.com/plan-install/literature.aspx. Recommended fasteners are those which are recommended by the manufacturer of Deckorators Stair Tread. Compatible fasteners are those which have been tested and recommended for use with Deckorators Stair Tread by the fastener manufacturer. The use of a non -recommend- ed fastener will not void the Deckorators Decking Warranty; however if a stair tread failure is caused by the use of a non -recommended fastener, any corresponding warranty claim will be denied. For ease of installation, we recommend using 3" corrosion -resistant, composite wood deck screws. These screws help minimize the common "mushroom" effect that sometimes occurs when using standard fasteners. They can also reduce the amount of pre -drilling and countersinking. If using ordinary coarse thread deck screws, always pre -drill a pilot hole and countersink prior to driving screws. Screws must be driven flush with the Deckorators stair tread surface. Do not over -tighten. Use two fasteners per stair tread at each stringer. For any stair tread where two boards meet end -to -end, an additional stringer is required so each end is supported. Always pre -drill a pilot hole and countersink at board ends when using other composite or wood screws. Be careful not to over -tighten screws near board ends. Like most composites, Deckorators stair tread will have color variations from piece to piece. This is due to naturally occuring variations in wood fibers and polymers. Purchasing all required stair tread material at one time is recommended, as manufacturing runs can pro- duce slightly different colors. Do not install if color variation is not acceptable. Mold and mildew can be a nuisance on any exterior building surface, regardless of the material. If the conditions are right, they will grow on wood, plastic, concrete, metal, and other surfaces. Mold formation is the most prevalent in consistently wet, shaded areas. Spores from the natural enviornment are carried by the wind and commonly land on deck surfaces. It is important to note that the appearance of mold/mildew is a function of nature, not necessarily a deficiency with any of the material on which it grows. Periodic washing with soap/mild detergent and water will help remove surface dirt. This will also help prevent the buildup of pollen, debris and spores that can cause and accelerate mold/mildew growth. Caution: A pressure washer must not be used to "blast" mold/mildew or soils from a deck surface. The abrasive nature of water stream can potentially cause damage by driving spores deeper into the material, which may create a more challenging problem to remedy. A pressure washer with a fan -tipped nozzle must only be used to lightly wet or rinse wood or composite deck surfaces. There are many deck wash and exterior cleaning products available at retail. Only use cleaners intended for your application. Instructions provided by the manufacturer must be followed. Some cleaning products and inhibitors may be more effective than others, depending on the enviornmental conditions your deck is subjected to. Additionally, it is always a good idea to test the cleaner in a small, inconspicuous area prior to applying it the the entire deck (www.deckorators.com). As with deck washes, there are several mold -inhibitor products available from paint stores, hardware stores, online outlets and home centers to prevent long-term mold/mildew growth. For any product selected, be certain to read, understand, and follow all instructions provided by the manufacturer. Depending upon the enviornmental factors affecting your deck, some preventative cleaning producrs may be more effective than others. It may be necessary to try more than one product. For ongoing preventive maintenance, follow the man- ufacturer's recommendation. Note: Deckorators is not suitable for structural use. It must not be used for primary load -bearing members such as posts, joists, beams, or stringers. The same common-sense precautions should be taken when handling Deckorators as with wood or other building materials. Dust masks and eye protection devices are recommended to avoid possible irritation from sawdust chips. Gloves will help protect hands. Hands should be washed after construction work. THE DIAGRAMS AND INSTRUCTIONS IN THIS BROCHURE ARE FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT MEANT TO REPLACE A LICENSED PROFESSIONAL. ANY CONSTRUCTION OR USE OF THE PRODUCT MUST BE IN ACCORDANCE WITH ALL LOCAL ZONING AND/OR BUILDING CODES. THE CONSUMER ASSUMES ALL RISKS AND LIABMYASSOCIATED WITH THE CONSTRUCTION OR USE OF THIS PRODUCT. THE CONSUMER OR CONTRACTOR SHOULD TAKE ALL NECESSARY STEPS TO ENSURE THE SAFETY OF EVERYONE INVOLVED IN THE PROJECT, INCLUDING, BUT NOT LIMITED TO, WEARING THE APPROPRIATE SAFETY EQUIPMENT. EXCEPT AS CONTAINED IN THE WRITTEN LIMITED WARRANTY, [UNIVERSAL CONSUMER PRODUCTS, INC.] DOES NOT PROVIDE ANY OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, AND SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING CONSEQUENTIAL DAMAGES.