2025-01876CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 63) 295-3060 YAX: (763) 295-4404 ADDRESS : 9320 CEDAR ST S PIN : 155207001010 LEGAL DESC : MONTICELLO BUSINESS CTR 3RD ADDN LOT 001 BLOCK 001 PERMIT TYPE : FIRE SAFETY PROPERTY TYPE : COMMERCIAL CONSTRUCTION TYPE : FIRE ALARM SYSTEM VALUATION : $ 20,000.00 NOTE: INSTALL NEW ALARM COMBO PANEL. REPLACE 2 NEW KEYPADS. NEW HORN STROBE IN HEALTH SERVICE ROOM. REPLACING CEILING TILES. INSTALL NEW STROBE IN PERSONNEL ROOM. INSTALL STROBE IN REAR ALCOVE. INSTALL NEW STROBES IN PICK UP STORAGE. RELOCATE TWO EXISTING NOTIFICATION DEVICES IN SALES. MAKE FINAL CX CONNECTIONS, AND ADD SYNC MODULE TO NEW FIRE PANEL. liiiiiiiiiiiiiiiiiiiiillillillillilligim 2 0 2 5— 0 1 8 7 6* DATE ISSUED: 12/22/2025 Permit #: 2025-01876 APPLICANT FIRE SUPPRESSION FEE 340.53 PLAN REVIEW - FIRE 221.34 WACHTER INC STATE SURCHARGE, OTHER VAL 10.00 16001 WEST 99TH STREET KS 66219- TOTAL 571.87LENEXA, Payment(s) 479) 757-8286 CHECK 355825 571.87 OWNER WAL-MART REAL EST BUSINESS TR 1301 1OTH ST SE PROP TAX DEPT #8013 AR 72716-0555 AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. O FIRE DEP.T. FIRE PROTECTION/ALARM PERMIT APPLICATION 103 CHELSEA ROAD MONTICELLO, MN 55362 PHONE: 763-295-3060 E (D L" 0 V za ID i Project Address: 9320 CEDAR ST Monticello, MN 55362 Lot Block Development Legal 001 001 Owner WAL-MART REAL EST BUSINESS TR I Telephone E-Mail Address 4797578286 onlinepermits@wachter.com Contractor License Number E-Mail Address Wachter, Inc./Jared Botteron EA003725 online permits@wachter.com Mailing Address 16001 W 99th St. Lenexa, KS 66219 Contact Person Telephone Mobile Telephone Katy Savage 4797578286 Property Single Family Two -Family Multifamily Townhome Agricultural Type Residential Residential Residential iCHECK ONE) 0 Commercial Industrial Institutional Public / Gov't OTHER Fire Protection Permit Type Project Valuation Fire Wet Sprinklers # of Heads Suppression System ElDry Sprinklers - Pressurized # of Heads $ Chemical, Ansul / Comm Kitchen - OTHER # of Heads Fire Suppression Monitoring System $ Fire Alarm System ® Building Fire Alarm System 20,000.00 Install new alarm combo panel. Replace 2 new keypads. New horn strobe in health service room. Replace ceiling tiles. Instali new strobe in personnel room. Install strobe in rear alcove. Insta'I new strobes in pick up storage. Relocate two exist - Description ing notification devices in sales. Make final CX connections, and add sync module to new fire panel. of work: OTHER FIRE PROTECTION SYSTEM (Specify Type & Number) Si ure of ire Protection Contractor Date Signaturp of Owner (If Owner t.s Buddor) Date c I hereby apply for a fire protection permit and acknowledge: the information above is complete and accurate; the work will be in conformance with the ordinances or,d codes of the City of Monticello and lL1innesoto State Building and Fire Codes; I understand this is not a permit but only an application for permit; work is not to start without permit; work will be in accordance with the Approved Plan when City plan approval required. This application and any issued permit may become null and void if permit is not issued or work is not commenced within 180 days, or if work is suspended or abandoned for a period of 180 days I hereby certify that 1 have read and examined this application the granting of a permit does not presume to give authority to violate or cancel the provisions of any rher state or local low regu!oting construction or the performance of construction. B - VQR CtTYaE LY PLAN CHECK REQUIRED Plans Checked By Iykl 65% of Permit Fee Approved for Issuance Date _ Fire Protection Permit Fees Project Valuation to be used in computing permit fee is the fair market value of work, including the total costs of materials, labor, profit and overhead for which the permit is issued. Minimum Permit Fee (All Permit T)pes) 100.00 Fire Suppression System 1.25% of Project Valuation Fire Alarm System 1.25% of Project Valuation Commercial Fuel Storage Tank 1.25% of Project Valuation Other Fire Protection System 1.25% of Project Valuation Plan Review Fee (Charged For All Permit Types When Plans Must Be Submitted) 65% of Permit Fee Minnesota State Surcharge must be charged in addition to permit fees for all permit types: 0005 x Project Valuation DO NOT SEND A CHECK WITH YOUR APPLICATION All submissions must be electronic and include the following: Application Plans Spec sheets Email electronic files to Eire.Marshal@MonticelloMN.gov FIRE ALARM PRODUCT DATA WALMART STORE #3624 9320 CEDAR ST MONTICELLO, MN 55362 4ont cell il•i D!hG $4fETY APPROVED FILE Cl1PY REVIEWED FOR COnE C0".7PLIANCE YCT TO FIELD IN'SPFCTION Cat:.•__" ! 7 Signature: Jason M. Scates, P.E. 1805 N. 2°d Street Rogers, AR 72756 The product data sheets included herein are for reference to indicate the specific products and materials that were included in the Fire Alarm design for this project. These products and materials are being provided as work products of other entities. The Engineer of Record for the Fire Alarm design project ( Jason M. Scates, P.E. ) does not intend to portray any responsibility for these products other than to specify them as finished products and materials for inclusion as components in the Fire Alarm design. www.boschsecurity.com ( 4L BOSCH Invented for life The B9512G Control Panel and the B8512G Control Panel are the new premier commercial control panels from Bosch. B9512G control panels integrate intrusion, fire, and access control providing one simple user interface for all systems. With the ability to adapt to large and small applications, the B9512G provides up to 599 individually identified points that can be split into 32 areas. The control panel can communicate through it's built- in Ethernet port (not applicable to "E" control panels), or through compatible plug-in modules that can send events over the public switched telephone network PSTN) or over cellular network communications. Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three Provides up to 599 points using a combination of hardwired or wireless devices for installation flexibility, and up to 32 areas and 32 doors for up to 2,000 users On -board Ethernet port for Conettix IP alarm communication and remote programming, compatible with modern IP networks including IPv6/ IPv4, AutolP, and Universal Plug and Play Installer -friendly features including onboard USB for easy on -site RPS programming, plus support for Remote Connect Service and plug-in PSTN and cellular communication modules for simple installation and communications Remote Security Control (RSC) app which allows users to control their security systems - and view system cameras - remotely from mobile devices such as phones and tablets For users, programmable keypad shortcuts, situation sensitive on -screen help, and a bilingual user interface make system operation simple and easy. With the B9512G Control Panel, you can: Monitor alarm points for intruder, gas, or fire alarms. Program all system functions local or remote using Remote Programming Software (RPS) or by using basic programming through the keypad. Add up to 32 doors of access control using the optional B901 Access Control Module. (Optionally use the D9210C Access Control Interface Module for up to eight of the 32 doors.) The B9512G is a direct replacement for previous control panel models D9412GV4, D9412GV3, D9412GV2, and D9412G. www.boschsecurity.com C"J BOSCH Invented for life The B926F Fire Keypad is a fully supervised SD12 device for fire applications. Each keypad has user -adjustable backlit keys, a display that shows system messages, and a sounder. The sounder emits distinct condition tones to alert you to a fire alarm, a fire trouble, or fire supervisory events as they occur. The keypad includes fire status indicators and fire function keys. LCD display The keypad uses words, numbers, and symbols to show the status of the security system. When several events occur, the keypad shows each event in order of priority. Keys Each keypad has 10 number keys and 5 navigation keys. When pressed, keys turn on keypad backlighting and emit the keypress tone (short beep). The keypad has 4 Fire function keys: ACK. Press to acknowledge the system alarm or trouble condition. SILENCE. Press to silence fire alarms or troubles. Fire keypad with fire function keys: ACK, SILENCE, RESET, and DRILL 2-line LCD display with up to 32 character point, user, and area names Simple menu -style user interface with dedicated function buttons for common commands, including status indication Quickly identifiable, visual indicators for critical system statuses Simple installation with self-locking base and chassis design, plus built-in bubble level RESET. Press to reset devices such as smoke detectors, and clear restored points. DRILL. Press and hold to initiate a fire drill. Audible tones The keypad has a built-in sounder that produces several distinct warning tones. The tones are differentiated so that the user can recognize an event simply by hearing its associated tone. Status indicators The status indicators on the keypad provide a quick visual reference for system status. The indicator lights when the system is ready to turn on (arm). The indicator lights when the system is on (armed). The indicator lights when dangerous gases are present including carbon monoxide (NFPA 720). The indicator lights when the system has power. AL1002ULADAffl: Altrom x NAC Power Extenders Overview Rev. AL 1002ULADA )3102015 AL 1002ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories. S_ pecifii Input: Power input 120VAC 60 Hz, 5 amp. Two (2) Class A, Style Z or two (2) Class B, Style W, Y FACP inputs. Two (2) NC dry contact trigger inputs. Output: Class 2 Rated power -limited outputs. 24VDC @10 amp max total alarm current. 2.5 amp max current per output. Separate 1.0 amp auxiliary output. Programmable supervised indicating circuit outputs: Four (4) Class B, Style W, Y or Two (2) Class A, Style Z or One (1) Class A, Style Z and Two (2) Class B, Style W, Y. Thermal and short circuit protection with auto reset. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Automatic switchover to stand-by battery when AC Fails. Zero voltage drop when switching over to battery backup. Supervision: AC fail supervision (form "C" contact, 1 amp / 28VDC). Factory set for 30 seconds with optional 2.5 to 3 hour delay setting (field selectable). Instant local AC trouble reporting relay form "C" contact, 1 amp / 28VDC). Battery presence and low battery supervision form "C" contact, 1 amp / 28VDC). rations Visual Indicators: Input and output status LED indicators. Special Features: 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. Sync protocols include Potter/Amseco, Faraday, Gentexg, System Sensors, and CooperWheelockg. Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). Compatible with 12VDC or 24VDC fire panels. Output loop supervision steered to input l or input 2. Signal circuit trouble memory (helps identify intermittent loop problems). Common trouble input and output. Ground fault detection. Unit includes power supply, red enclosure, cam lock, and battery leads. Mechanical: Enclosure Dimensions (H x W x D approx.): 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm) Product weight (approx.): 12 lbs. (5.44 kg). Shipping weight (approx.): 13.3 lbs. (6.03 kg). Agency Approvals UL Listed Control Units and Accessories California State Fire Marshal Approved. U` for Fire Alarm Systems (UL 864) Ninth 'IC•' Edition VIC M EA NYC Department of Buildings Approved Approved FM Factory Mutual Approved. APPROVED www.boschsecurity.com Cl BOSCH Invented for life B96 Keypad Trim Bezel Cover the wall footprint of previous keypads when replacing them with the new, slim design of B Series keypads. The white trim bezel is 8.6 in x 6.3 in x 0.12 in (22 mm x 16 mm x 3 mm). Order number B96 www.boschsecurity.com OWF- BOSCH Invented for life l 11111 P-1, r 1 The D273 Family includes the following detector models: Model Description D273 Four -wire D2731S ! Four -wire with an isolated 135'F (57'C) heat sensor and sounder D273TH Four -wire with 135'F (57'C) heat sensor D273THC Four -wire with 135'F (57'C) heat sensor and auxiliary relay D273THCS' Four -wire with 135'F (57'C) heat sensor, auxiliary relay, and sounder D273THE Four -wire with 135'F (57'C) heat sensor and EOL relay D273THR2 Four -wire with 135'F (57'C) heat sensor and trouble relay D273THS! Four -wire with 135'F (57'C) heat sensor and sounder D273THES= Four -wire with 135'F (57'C) heat sensor, sounder, and EOL relay 12 VDC or 24 VDC input Designed for commercial or residential use Four -wire application Light -emitting diodes (LEDs) indicate the status of the chamber, power, and alarm Removable terminal block to simplify wiring connections Sounders produce 85 dB at 10 ft (3 m) The trouble relay indicates both Dirty Smoke Chamber and/or Power Loss conditions. Each of the detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. These detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. www.boschsecurity.com BOSCH Invented for life The FMM-100 family are versatile, high -quality, metal fire alarm manual stations. Single-action or dual -action models are available. All models come with a key lock and contain gold-plated contacts to resist corrosion. Operation Single-action When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft 15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual -action With the dual -action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Single or dual action P. Terminal connections Gold-plated alarm contacts for corrosion resistance Surface or weatherproof back boxes Certifications and approvals Region Certification USA UL UNIU: Boxes, Non -Coded (UL38), UNIU7: Boxes, Non -Coded Certified for Canada (cULus) CSFM see our website NYC- 382-94-E, Vol. VI MEA Compatibility Information These manual stations are compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations These manual stations can be surface mounted on either the FMM-100BB-R Surface -mount Back Box or the FMM-100WPBB-R Weatherproof Back Box. They can also be flush mounted on a standard single -gang back box. SYSTEM SENSOR LmSeries and LoSeries with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper -resistant construction Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use Agency Listings 5Xkk AC SIGNALING c@us U< o FM USTEO MCn fin APPROVED Horn Strobes Horns: horns: 3057072 7300-16530525 and Strobes: S4011 S4011 rM23FPUSG195 7135-1653-05M S5512. S4011 7135-1653:0526 The System Sensor L-Series and L-Series with LED platform offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. AVDS916-01 - 10/03/2023 - Gage 1 SYSTEM SENSOR Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert@ Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug- in design with minimal intrusion into the back box Tamper - resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/ 75 candela Field - selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting Agency Listings SIGNauNs W LISTED van approved 71225-1 ai88 (horn strobes, s, S4011 ( ch:rnes, horn strobes, tams) 3023572 YEA452-05-E chine strobes) S5512 ( strobes) 7135-1653 0189 (horns, chimes) W S_ _y s t e m S e n s o The SpectrAlert Advance series offers the most versatile and easy - to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation, SpectrAlert Advance utilizes a universal mounting plate so you can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SYSTEM SENSOR Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, IP56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40OF to 151 OF Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper -resistant construction Listed for ceiling or wall mounting Agency Listings SIGNALING L13TED i M S4011 (chtrnes horn strobes, horns) APPROVED S3593 (outdoor and aler, strobes) 302 1- NEA7300-1653 187 (outdoor sWobes) approved 1251ss3,8gc ) MEA452-05-E 71351653 189 (horns, chines) SPECTRA.-W-kWrt f r o m S s t e m S e n s o SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40OF to 151 OF. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. www.boschsecurity.com ( 4 BOSCH Invented for life This module is used for wiring connections to remote signaling devices. You can connect up to twelve D192G modules to the same system on compatible control panels. Wiring is supervised for open, short, or grounded circuit faults. The module powers notification appliances from the control panel power supply or from an Underwriters Laboratories, Inc. (UL 1481) Listed auxiliary 12 VDC or 24 VDC regulated/power-limited power supply for fire protective signaling units and commercial/residential burglar units. This feature allows the system to support more signaling devices on longer wire runs. It also allows the use of 12 V or 24 V notification appliances requiring the appropriate power supply. Supervises 12 VDC or 24 VDC NACs The D192G powers the notification devices from either the control panel's power supply or from a UL Listed Auxiliary 12 VDC or 24 VDC regulated power -limited power supply for use with Fire Protective Signaling Units and Commercial and Residential Burglar Units. The choice of power supply allows the use of 12 V or 24 V notification devices. is. Supervises 12 VDC or 24 VDC notification appliance circuits (NACs) Supervised signal silencing switch P. Notification appliance circuit rated at 3.0 A P. Multiple module configurations Mounts in panel enclosure Supervised Signal Silencing Switch The D192G module has a toggle switch for silencing the notification devices while testing the alarm panel. When this toggle switch is in the Silence (Off) position, the module indicates a supervisory trouble condition to the control panel. Multiple Module Configurations Several modules can be connected to the same zone or point on the control panel. If individual annunciation of a notification appliance circuit is desired, D192G modules can be connected to separate zones or points on -board or through the D8128D OctoPOPIT Eight -point Expander. Mounts in Panel Enclosure The D192G mounts inside the control panel enclosure using existing mounting holes or with a D137 or D138 Mounting Bracket. Refer to the control panel's installation guide for more information on mounting. www.boschsecurity.com i BOSCH Invented for life Provides point identification for up to 100 connected addressable initiating devices using POPITs Supervises wiring to devices for circuit integrity Expands the number of points in the system Compact size Interconnect wiring connectors for easy installation The B299 POPEX Module is an SD12 compatible Region Certification device. The module communicates to the control panel over the SD12 bus, and provides support for up to 100 UL UL 1610 - Central Station Burglar Alarm POPIT (Point Of Protection Input Transponder) Units devices. This occurs over a single expansion loop using UL UL 1635 - Standard for Digital Alarm two pairs of terminals. Communicator System Units UL UL 294 - Standard for Access Control System overview Units and Systems Each module installs in the control panel enclosure or UL UL 365 - Police Station Connected Bur- in an adjacent approved enclosure. Future system glar Alarm Units expansion is very economical as the module supports UL UL 609 - Standard for Local Burglar zone expansion through supporting D9127U/T POPIT Alarm Units and Systems modules and POPIT'ed detectors. The POPIT modules UL UL 636 - Holdup Alarm Units and Sys - can be placed anywhere along the two -wire data tems expansion loop from the module. UL UL 864 -Standard for Control Units and Certifications and approvals Accessories for Fire Alarm Systems UL UL 985 - Household Fire Warning Sys - Region Certification tem Units USA ANSI- CP-01-2010-Control Panel Standard - CSFM California Office of The State Fire Mar- SIA Features for False Alarm Reduction shall UL FCC Part 15 Class B UL UL 1023 - Household Burglar Alarm Sys- Canada ULC tem Units ULC CAN/ULC S303 - Local Burglar Alarm UL UL 1076 - Proprietary Burglar Alarm Units and Systems Units and Systems www.boschsecurity.com C4 BOSCH Invented for life The D9127 Series POPIT Modules includes the D9127T with magnetic tamper switch) and the D9127U without tamper). They are used with a D8125 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on -board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two -wire data expansion loop from the D8125 module. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kO end -of -line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. Provides point identification of initiating devices Supervises wiring to devices for circuit integrity Expands the number of points in the system P. Compact size Terminal connections for reliability Certifications and approvals Rogion Certification USA UL UL UL 365 - Police Station Connected Bur- glar Alarm Units UL UL 464 - Standard for Audible Signal Ap- pliances UL UL 609 - Standard for Local Burglar Alarm Units and Systems UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems UL UL 985 - Household Fire Warning Sys- tem Units UL UL 1023 - Household Burglar Alarm Sys- tem Units UL UL 1076 - Proprietary Burglar Alarm Units and Systems UL UL 1610 - Central Station Burglar Alarm Units UL UL 1635 - Standard for Digital Alarm Communicator System Units FM www.boschsecurity.com i BOSCH Invented for life The D130 Auxiliary Relay Module can be used with all Bosch Security Systems control panels. The relay module consists of a 12 VDC or 24 VDC relay. This device allows the system to handle larger amounts of current or different voltages that are beyond the control panel's auxiliary power rating, or the rating of modules such as the D8129 OctoRelay. Notice A UL Listed, 12 VDC or 24 VDC auxiliary power supply is required to supply power to the D130's coil. The relay is polarized and has two sets of non -latching Form C contacts. When the contacts are in the inactive state, the normally -closed terminal has continuity with the common terminal. When the contacts are in the active state, the normally -open terminal has continuity with the common terminal. The relay is activated by switching polarity. A red LED lights to indicate the coil is energized. 12 VDC or 24 VDC relay Allows switching of current or voltage Two non -latching Form C dry contact outputs Red LED shows coil is energized Mounts in control panel enclosure Initiating Circuit Application The D130 is commonly used with a D125B Dual Class B Initiating Module and a UL Listed 24 VDC power supply. In this configuration power to the detectors can be interrupted by a command from the fire alarm control panel (FACP). Region Certification USA UL APOU: Proprietary Alarm Units UL1076), UOJZ: Control Units, System UL864, 9th edition) FM CSFM 7167-1615: 100 and 7165-1615: 119 NYC- 12-92-E, Vol. II 12-92-E, Vol. II MEA NYC- 12-92-E, Vol. 12 12-92-E, Vol. 12 MEA NYC- 12-92-E, Vol. 15 12-92-E, Vol. 15 MEA www.boschsecurity.com (OD BOSCH Invented for life The D8130 Door Release Module is an accessory for fire alarm control panels (FACPs) that controls system functions commonly required in National Fire Prevention Association (NFPA) 72 fire alarm installations. Two independent Form C dry contacts, each rated at 5 A, connect low -voltage circuits to magnetic door holders, pilot relays, or contactor units for function control. Typical applications are: releasing fire doors, emergency exit doors, and stairwell doors elevator recall HVAC control Contact Activation The control panel indicating output activates the contacts of the D8130. A red Alarm Input LED indicates contact activation. The duration of the contact activation follows the programmed indicating circuit time. Use a jumper to set the contact activation to be instant or delayed by 14 sec when there is an alarm condition. With the delay option selected, a 14 sec delay also occurs upon restoral. This delay feature is useful for momentary bell tests. Two Form C (5 A rated) contacts Remotely controls fire system devices Instant or delayed relay activation and restoral Relay closure follows indicating circuit duration Disable switch supervised for system testing If the user silences the alarm output, the D8130 contacts deactivate. Latching features must be provided for pilot relays or contactor units requiring control beyond the programmed indicating device time or after manual silencing of the indicating circuits. Supervised Disable Switch To facilitate fire alarm installation testing, the D8130 Module contains a supervised disable switch that prevents operation of the relay contacts. An amber Disable LED indicates when the switch is in the disable position. Connect one or more D8130 modules to any unused 1 kO zone or point of the control panel to detect module disabling. A trouble is indicated when the D8130 switch is in the disable position, and a restoral signal is sent when the switch is returned to the normal position. (Refer to the control panel's Program Entry Guide for details on programming a trouble signal for an open or short condition.) When the contacts are activated with the switch in the normal position, no trouble indications are sent to the control panel. Release Contact Outputs A normally -open (NO) terminal, a normally -closed (NC) terminal, and a common (COM) terminal are provided for each D8130 contact. In the inactive state of the contact, the NC terminal has continuity with the COM terminal. In the active state of the contact, the NO terminal has continuity with the COM terminal. z n oC QrD o v m o SI fl < T r c z S = rri rb N D D (D Q o p ot O n f1 n rD :3 N p O Ln CD rD LA00ooon Lnrr O N 6 Q O O f p • O M < v 0 Q f rD CD-CrD = in 33 rp Ln N • kInD N (D fp yfl, w rD rD fl vi a, 3 co N rD n o 3 m M. o 0ort. l< N. rD o a- -Z3 o ° ro O fDn YJ rD rD C) ul QL ro N O -p o< o o •p o Q S O•p < :3n a, 0 n 1p rD — rD n = D rD -. rD rDA (D Ln Un n " n O0 o 0OQOrrN' v W rD (D -0 l 3 LT r) o- n-r n n 00 _ < aF '. rD o D= VOO ^ O D. n T X. D 0) D N. rD 1p TV rD OD O rD O< Q rD Q 1 v1V1rY : rD 1 n m , (D' D O rD (D D-. r 3' o rD o to t ' D rD rD Q rD rD Ln Q O < O— cu _Q -r r* Q n n . ,--, D- O ' O a, ' N, w ( l rD D o" w n . O o n, D- 0 c: n 0 0 o rt 3 3 n * _*' Lo rD n, in O r c o Q n 3 d S. -4, SQO30 fl, p v C rD D rD N 3 rD N N n rD 1 rD l/) rD (D Q o :3 r r rD Q Q 6 Q 0 n rD rD D n rD n -OrDvZ) l0 rD Q - * n 3 QrD j,< rD o- Q _ rD Q n d rD fl o o° O o a, Q rD Ln www.boschsecurity.com ; ;;1 BOSCH Invented for life The cellular communicator enables secure two-way IP communication over the Verizon 4G LTE cellular network by plugging into a compatible control panel or communicator interface. Typical applications are: Alarm reporting to a central station Remote control panel programming through Remote Programming Software with supported control panels Remote monitoring and control through a mobile application with supported control panels Personal notification using SMS for compatible control panels Notice Ce lular capability requires an Installer Services account and appropriate data plan. 0 Secure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon 4G LTE cellular network Remote programming and monitoring of compatible Bosch panels Personal SMS message and e-mail notification options Direct configuration from Bosch Remote Programming Software (RPS) eliminating the need for separate configuration Simple LED status information and advanced keypad diagnostics available with easy 2 step plug-in installation, troubleshooting, and maintenance tBOS CH 3 a Callout - - Description 1 - Cellular communicator 2 -Compatible control panel 3 - Antenna cable 4 - - Magnetic base antenna Callout — Description 7 - - Remote PC's network connection 8 - - Remote PC running RPS 9 - - Personal SMS notification 10 - -Ethernet connection