4010 - VCE1 VISION CENTER LIGHTING PLANS AND SCHEDULES - 3624ELECTRICAL SYMBOLS LEGEND 03.29.19 (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) SYMBOL DESCRIPTION ko 0/O ❑ LIGHT FIXTURE (WALL MOUNTED/CEILING MOUNTED) O LIGHT FIXTURE LIGHT FIXTURE, NIGHT LIGHT VOLUMETRIC LIGHT FIXTURE TRACK LIGHTING / ® EXIT FIXTURE (WALL MOUNTED/CEILING MOUNTED) / >oil EMERGENCY LIGHT (WALL MOUNTED/CEILING MOUNTED) m / D& EMERGENCY LIGHT REMOTE HEADS (WALL MOUNTED/CEILING MOUNTED) SINGLE POLE SWITCH $3 3 -WAY SWITCH $4 4 -WAY SWITCH $K KEYED SWITCH $D DIMMER SWITCH $VS VARIABLE SPEED SWITCH $M MANUAL MOTOR SWITCH $OS SINGLE POLE OCCUPANCY SENSOR SWITCH $OS2 DOUBLE POLE OCCUPANCY SENSOR SWITCH CEILING MOUNTED OCCUPANCY SENSOR SWITCH d RECEPTACLE,DUPLEX RECEPTACLE, DUPLEX, MOUNTED HORIZONTALLY RECEPTACLE, GFI ❑® RECEPTACLE, DUPLEX FLUSH FLOOR RECEPTACLE, DUPLEX ISOLATED GROUND FLUSH FLOOR RECEPTACLE, DOUBLE DUPLEX �{ RECEPTACLE, DUPLEX �J ISOLATED GROUND �{ RECEPTACLE, DOUBLE DUPLEX, $ ISOLATED GROUND RECEPTACLE, SIMPLEX TWIST LOCK, L5 -15R, UNO RECEPTACLE, SIMPLEX TWIST LOCK, ISOLATED GROUND, L5 -15R, UNO RECEPTACLE, DUPLEX TWIST LOCK, L5 -15R, UNO RECEPTACLE, DUPLEX TWIST LOCK, ISOLATED GROUND, L5 -15R, LINO ( RECEPTACLE, SPECIAL RECEPTACLE, SIMPLEX RECEPTACLE, PLUG -MOLD O JUNCTION BOX (WALL MOUNTED/CEILING MOUNTED) O THERMOSTAT (WALL MOUNTED/CEILING MOUNTED) O ALARM JUNCTION BOX, (WALL MOUNTED/CEILING MOUNTED) ALARM JUNCTION BOX, ® FOR REMOTE TEST/RESET (WALL MOUNTED/CEILING MOUNTED) SO SMOKE DETECTOR ❑h NON-FUSED DISCONNECT IZh FUSED DISCONNECT EQUIPMENT CONNECTION POINT (PROVIDED WITH EQUIPMENT) CIRCUIT, CONCEALED IN WALLS OR CEILING, E INDICATES EXISTING WIRING CIRCUIT, CONCEALED IN SLAB FLOOR, E INDICATES EXISTING WIRING CIRCUIT, EXPOSED, E INDICATES EXISTING WIRING ------------ LOW VOLTAGE WIRING I -I CONDUIT SLEEVE = FLUSH MOUNTED PANELBOARD SURFACE MOUNTED PANELBOARD - TELEPHONE / DATA BOX FOR ISD LOW VOLTAGE CABLE BOX FOR OTHER ❑- TELEPHONE, FLUSH FLOOR O MOTOR 0/(2) TELEPOWER POLE Q PUSH BUTTON BUZZER SS SAIL SWITCH JUNCTION BOX ( J`I HORN/STROBE DH DOOR HOLD OPEN TC TIME CLOCK ABBREVIATIONS a, b, c LOWER CASE LETTERS INDICATE SWITCHING CONFIGURATION AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE C CONDUIT CCT CIRCUIT CF CEILING FAN CW CASH WRAP EC ELECTRICAL CONTRACTOR EF EXHAUSTFAN ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER G GROUND GC GENERAL CONTRACTOR GFEP GROUND FAULT EQUIPMENT PROTECTION GFI GROUND FAULT CIRCUIT INTERRUPTER HD HAND DRYER IG ISOLATED GROUND LCU LIGHTING CONTROL UNIT NL NIGHT LIGHT NTS NOT TO SCALE REC REFRIGERATION ELECTRICAL CONTRACTOR RC REFRIGERATION CONTRACTOR RH RADIANT HEATER SC SECURITY CAMERA TR TAMPER RESISTANT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE WH WATER HEATER WP WEATHER PROOF WR WEATHER RESISTANT LIGHT FIXTURE SCHEDULE "OW" FIXTURES AND LAMPS ARE FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR. "GC" FIXTURES AND LAMPS ARE FURNISHED AND INSTALLED BY THE CONTRACTOR. TYPE SUPPLIED BY DESCRIPTION VENDOR/ MANUFACTURER MODEL VOLTAGE INPUT VA COLOR TEMP LIGHT SOURCE LAMP QTY MOUNTING COUNT 19 OW EMERGENCY LIGHT REXEL INC EVHC6IDP-WM W/ T BAR HANGER 120/277 3 VA FIXTURE MOUNTING HEIGHT. INTEGRAL LED (BLACK) WALL / CEILING 2 85 OW 13" GLOBE PENDANT LIGHT WITH MEDIUM BASE LAMP SOCKET, CORD MOUNT, WHITE FINISH REGENCY P4406-29 120 14 VA 3000k 14A21 DIM/830 [GRC] (LED A19 LAMP, 1600L) LIGHTING IN ADJUSTMENTS WILL BE SUSPENDED 4 87 OW 3 LIGHT RECESSED MUTIPLE, WHITE FINISH REGENCY XAR13/Ym20/25c-25c-25c/30K/1400/WH/WH 120/277 51 VA 3000K MODULAR LED CONTROL RECESSED 38 89 OW UNDER CABINET LIGHTING - 22" QUALSERV RT5HO-LED22-30FR-2-000 120 12 VA 3000K INTEGRAL LED WITH MILLWORK. INSTALL LIGHT SURFACE 2 91 OW 4FT SUSPENDED LED LINEAR SLOT LIGHT REGENCY OLS-D-LED-2-S-4'0"-750L-DIM10-MVOLT-30K-85-WH 120/277 27 VA 3000K INTEGRAL LED r2.2. VISION CENTER SPECIAL PROJECT SUSPENDED 3 92 OW 8FT SUSPENDED LED LINEAR SLOT LIGHT REGENCY OLS-D-LED-2-S-8'0"-750L-DIM10-MVOLT-30K-85-WH 120/277 54 VA 3000K INTEGRAL LED SUSPENDED 3 94 OW UNDER CABINET LIGHTING - 58" QUALSERV RT5HO-LED58-30FR-2-000 120 24 VA 3000K INTEGRAL LED SURFACE 1 a O b TYPE 91 & 92 SUSPENDED LINEAR LIGHT O SENSOR =-� FIXTURES TO BE CENTERED BETWEEN REFER TO ARCHITECTURAL EXISTING LIGHT SWITCHES CEILING FEATURE BORDER AND SLATS. DRAWINGS FOR INSTALLATION OF SHOWN SHALL REMAIN REF ARCHITECTURAL DRAWINGS. TYPE 85, 91 AND 92 LIGHT FIXTURES. UNLESS NOTED OTHERWISE. Q U REFERENCE ARCHITECTURAL W WHEN REQUIRED, ADJUST LIGHTING LAYOUT PLANS FOR TYPE 91 & 92 LIGHT TYPE 87 LIGHT FIXTURES ALONG TO AVOID EXISTING SPRINKLER LOCATIONS. FIXTURE MOUNTING HEIGHT. PERIMETER TO BE AIMED AT PRODUCT (BLACK) RELAY BY GENERAL CONTRACTOR. (WHITE) CONTROL (BLUE) POWER CORD AND LIGHT FIXTURE UNIT CU300A CONNECTORS FOR UNDERCABINET OCCUPANCY SENSORS SHOULD TYPE 85 PENDANT LIGHT FIXTURES TO LIGHTING IN ADJUSTMENTS WILL BE BE PROGRAMMED FOR MAXIMUM BE CENTERED OVER TABLES. REF Q FURNISHED BY MANUFACTURER FOR AVAILABLE TIME DELAY SETTING. ARCHITECTURAL DRAWINGS FOR v INSTALLATION BY CONTRACTOR. EXACT LOCATION OF ALL TABLES. RELAY LOWER CASE LETTER DESIGNATION (RED) CONTROL CORRESPONDS TO LIGHT SWITCH CONTROL, � O TYPE 89 & 94 LIGHT FIXTURES TO BE TYP OF OPTICAL SALES LIGHTING. N CD N REFER TO THE VISION CENTER PROVIDED BY OWNER AND FURNISHED FURNISH AND INSTALL (3) HUBBELL POWER PLAN FOR THE LIGHT WITH MILLWORK. INSTALL LIGHT ATP1500C OCCUPANCY SENSORS WITH SWITCH AND RECEPTACLE FIXTURES ON UNDERNEATH SIDE OF CONTROL UNIT AND MODULE IN SERIES LOCATION FOR THE ADJUSTMENTS CABINETS AND PROVIDE LIGHT SWITCH WITH WALL MOUNTED SWITCHES, LAB UNDERCABINET LIGHTING. CONTROL AS SHOWN. REF 3-VCE1 O r2.2. VISION CENTER SPECIAL PROJECT TYP a b a b a b a O o 0 0 0 0 a O b a O O SENSOR =-� FUR HUB UNIJ ISH AND ELL CL1300A AND HUBBELL INSTALL CONTROL RELAY AAR I_ --(_16F1 OP ABOVE 3-1 CEILING REF WAITING 161489 CONTACTS 0 0 a b .N, pe SJR MW T a O OPTICAL ISALES I -VISION CENTER -POWER POLE FOR REFERENCE, TYP C F 3. b 3 11 O b a O O ADJUSTMENTS I I I 16.125 TYP I I I I I I 3 0 EXAM #2 VISION CENTER LIGHTING PLAN I 1/4" = V-0" We 3 129 I NL PRETEST 0 EXAM #1 GND CCT H2P-18 NEUTRAL (OPT SALES LTG ONLY) HOT 120V OR 277V HOT TO VISION CENTER PANELFGN (LIGHTING CCT LVC-15) TO LIGHTS TO LIGHTS SWITCHED HOT TO "a" LIGHTS SWITCHED HOT TO "b" LIGHTS SWITCHED HOT TO "c" LIGHTS SWITCHED HOT TO "d" LIGHTS HUBBELL TO ADDITIONAL ATP 1500C SWITCH "a" OCCUPANCY SENSORS (MAX OF 4 PER RELAY UNIT) SENSOR =-� SWITCH "b" ATP1500C REF LIGHTING PLANS FOR SWITCH "c" QUANTITY AND LOCATIONS +24V SWITCH "d" REF LIGHTING PLANS FOR Q U EXACT LOCATION W (RED) J (RED) D- HUBBELL (BLACK) RELAY (BLACK) (WHITE) CONTROL (BLUE) LU UNIT CU300A REF LIGHTING PLANS FOR p EXACT LOCATION OHO Q Z (WHITE) (BLUE) HUBBELL (BLACK) RELAY (BLACK) (RED) CONTROL (RED) � O UNIT AAR20P TO LIGHTS TO LIGHTS SWITCHED HOT TO "a" LIGHTS SWITCHED HOT TO "b" LIGHTS SWITCHED HOT TO "c" LIGHTS SWITCHED HOT TO "d" LIGHTS HUBBELL TO ADDITIONAL ATP 1500C OCCUPANCY -- OCCUPANCY SENSORS (MAX OF 4 PER RELAY UNIT) SENSOR =-� w MZ�oCE o �owF�wdz��z LU ATP1500C REF LIGHTING PLANS FOR Z QUANTITY AND LOCATIONS +24V w a�NJpzzQw'm Muz �w� SWITCH "e" OCCUPANCY SENSOR WIRING DI NTS MANUAL LIGHT SWITCH CONTROL, REF LIGHTING PLANS FOR LOCATION, TYP -4, SWITCHED HOT TO "e" LIGHTS TO LIGHTS TO LIGHTS AGRAM 8 EXISTING LIGHT SWITCHES SHOWN SHALL REMAIN UNLESS NOTED OTHERWISE. - D III II c, II II c, I II = Ell= = IIII L---_ III L____ II I— ILE_ ��\ 2X4 I I F - I F -1 \ ) TROFFER L L -1 j_ L -1 �/ LIGHTING I 16.126 I TYP OF 10 I IIII III I II I I IIII III III � III III � II III � II II II I III L====J L====J ===J I IIII � III II `� II I F -1F -1 \) OPTICAL (/ F -1 F -1 \) I- �I I I °Y L j_ L -1 SALES L- -1 L -1 I IIII III II II I III c, III III v II III c, II II II I III L___= J L====J III - J I II III WALL WASH III LIGHTS 16.126 III WALL WASH TYP OF 10 III LIGHTS I IIII � 16.126 I � I I III TYP OF6 r- - r r) - II-1-- ----------- II I I 16.489 REF 2-VCE1 O O O I� 0 PRETEST 0 ADJUSTMENTS d__ - $ lu I 16.125 111 I TYP LL 0 0 0 0 ;ONTACTS O r- _-) r--1 I I I I L -� L -= EXAM #2 VISION CENTER DEMO LIGHTING PLAN 1/4" = V-0" EXAM #1 $D GENERAL LIGHTING NOTES 01.31.20 1. EXIT SIGN MOUNTING A. WALL FIXTURE: CENTER 12" ABOVE DOOR OPENING. B. CEILING FIXTURE: ON CEILING OR AT HEIGHT SPECIFIED ON DRAWINGS. C. PENDANT FIXTURE: MATCH HEIGHT OF EXISTING PENDANT MOUNTED EXIT SIGNS. D. VERIFY MOUNTING HEIGHT WITH AHJ. E. COORDINATE LOCATIONS OF EXIT SIGNS TO ENSURE STORE SIGNAGE DOES NOT OBSTRUCT THEIR VIEW. F. THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE IS PROHIBITED. 2. EMERGENCY LIGHT FIXTURE INSTALLATION A. WALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE. B. PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS. C. REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK MOUNTED ON INTERIOR SIDE OF WALL 12" BELOW FINISHED CEILING OR AT BAR JOIST IN AREAS OF EXPOSED STRUCTURE. D. REFER TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ALLOW BATTERY TO CHARGE CONTINUOUSLY FOR A MINIMUM OF 24 HOURS BEFORE INITIAL TESTING. E. AFTER EMERGENCY LIGHT HAS BEEN POWERED DO NOT TURN OFF FOR EXTENDED PERIODS OF TIME. 3. EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS SHALL NOT BE SWITCHED. 4. PROVIDE SEPARATE BOXES FOR GANGED SWITCHES ON SEPARATE BRANCH CIRCUITS. KEYNOTES 16.100 PROVIDE BI -LEVEL LIGHTING BY ALTERNATING SWITCH LEGS BETWEEN LIGHT FIXTURES. (CHECKERBOARD) 16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESS NOTED OTHERWISE. 16.126 EXISTING LIGHT FIXTURE TO BE DEMOLISHED. 16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLY SERVING AREA LIGHTING THAT WAS REMOVED. MAINTAIN EXISTING CIRCUIT CONTROL UNLESS NOTED OTHERWISE. PROVIDE CONSTANT HOT FOR EMERGENCY EXIT AND LOCALLY CONTROLLED LIGHT FIXTURES. 16.131 CONNECT TO EXISTING CIRCUIT. 16.470 FURNISH AND INSTALL NEW 20 AMP, 120 VOLT CIRCUIT(S). FEED FROM PANELBOARD AS INDICATED. PROVIDE 20A-1 P CIRCUIT BREAKER IF NEEDED. E.C. SHALL MATCH MANUFACTURER, TYPE AND AIC RATINGS OF EXISTING CIRCUIT BREAKERS. 16.489 RELOCATE, EXTEND, AND RECONNECT CIRCUITRY AND ELECTRICAL DEVICES FOR RELOCATED AND/OR NEW EQUIPMENT. VERIFY CONDITION OF BRANCH CIRCUITRY, CONDUIT AND WIRE TO ENSURE THEY MEET ALL U.L. RATINGS AND REPLACE AS REQUIRED. VERIFY FINAL LOCATION OF RELOCATED/NEW EQUIPMENT WITH WALMART CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. PROVIDE LISTED HANDLE -TIE BETWEEN CIRCUIT BREAKERS SHARING COMMON NEUTRAL FOR SIMULTANEOUS TRIP. TYP OF ALL CIRCUITS SHOWN ON ALL ELECTRICAL SHEETS. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. TYPICAL OF ALL ELECTRICAL SHEETS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. TYPICAL OF ALL ELECTRICAL SHEETS. p+enb2 hitecture gineering 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 Engineer of Record Keith Allen Williams, P.E. Minnesota License No. 45549 LU LU L.U� O �, ww°oma U) w Fro O zwU �ZC7zQ LU w MZ�oCE o �owF�wdz��z LU m � W928 Z wQF ?5JwEozoOw a°O w w a�NJpzzQw'm Muz �w� O ¢�? °ccwn[[28!wL Q U �U� Zcv�O?Z01Z�Z 0w ¢=UOZ¢ W Za-0 G-90 <z <C -<0 J Q Q W 0-z w~ yomywO w w 0 0`4�j D- 00F w-'<W!0-5cno no< MwZz<5O�¢0wa��w z F_2°0awCE�U) D00)0LL¢PE U) z J U) z O U ISSUE BLOCK CHECKED BY: KAW DRAWN BY: HS PROTO CYCLE: 07-01-2020 DOCUMENT DATE: 08-07-2020 I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE- TYFF3 OR PRINTED AME: KEITH A. WILLIAMS DATE: 08/06/2020 LICENSE NUMBER: 45549 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION VISION CENTER LIGHTING PLANS AND SCHEDULES HEEVCEi Q LU U LU O %0 O D- O OC/) Q U 0 O W LU U) Z 1� z T ~4 Lu w LU U z N p OHO Q Z LU W J (-)LU W C) � O q o 0 N CD N Z LU LU O m C z m G O r2.2. VISION CENTER SPECIAL PROJECT ISSUE BLOCK CHECKED BY: KAW DRAWN BY: HS PROTO CYCLE: 07-01-2020 DOCUMENT DATE: 08-07-2020 I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE- TYFF3 OR PRINTED AME: KEITH A. WILLIAMS DATE: 08/06/2020 LICENSE NUMBER: 45549 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION VISION CENTER LIGHTING PLANS AND SCHEDULES HEEVCEi