Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Auto Center, Electrical, Fire Protection, refridgeration
AND #1 - I ZONE #2 - 36,458 GENERAL NOTES FT ¢rte #3 - 37, qO3 I FT 3jc� #4 - 47,186 12" MAXIMUM, FT STRUCTURE: al - 48,588 SQ. 8" MINIMUM IN I 1 1 • STEEL ROOF DECK SUPPORTED BY STEEL am 90. FT STOCKROOMS BEAMS AND COLUMNS. ROOF DECK *EXTERIOR WALLS ARE TO BE CONCRETE a _ �- t r L-> I_ C, (I BLOCK. -.-1° GLOBE VA. �■ *INTERIOR WALLS TO BE STEEL STUD WITH I I , I I INS C V j` < GYPSUM BOARD OR BLOCK. m £ • FINISHED CEILINGS ARE ACOUSTICAL TILE d I� t OR GYPSUM BOARD. -I' SIGHT GLASS O IA CRITERIA: i V) • ENTIRE BUILDING TO BE PROTECTED BY 5 WET -1 � F9 m ` AND i DRY SYSTEM DESIGNED TO NFPA 13 1999 ED. -10 t° UNION w/ RESTRICTED ORIFICE STOCKROOM DETAIL I I , I I I , I *ALL WET PIPING SYSTEM TO BE HYDROSTATICALLY R 12' WATER , EXISTIN TESTED AT 200 PSI FOR 2 HOURS. -- ---------- I • ALL TESTS TO BE WITNESSED BY THE FIRE DEPARTMENT ALL CONTROL VALVES TO HAVE TAMPER SWITCHES. MATERIALS: �2 PLUG / W/ TEE • ALL MATERIALS TO BE NEW AND MEET NFPA X 1 REDUCING FM AND U.L. STANDARDS. COUPLING • ALL HANGERS TO BE IN ACCORDANCE WITH 1= GL03E 5681 Y00° DRY PENDENT HEAD NFPA STANDARDS AND WALMART REQUIREMENTS. • THREADED PIPE 2" AND SMALLER TO BE SCH 40 ��° X i' -O° c ANSI/ASTM A135 WITH SCREWED FITTINGS PIPE NIPPLE : DOW CORNING 734z • GROOVED PIPE 2" THROUGH 4" TO BE DYNAFLOW PLASTID ADHESIVE ANSI/ASTM A795 WITH GROOVED FITTINGS. _ •GROOVED PIPE 1-1/4". 1-1/20. 6", AND 8" TO BE SCHEDULE 10 2 X i REDUCING o'q;ij[ ANSI/ASTM A135 WITH GROOVED FITTINGS. COUPLING n • DRY SYSTEM PIPE TO BE GALVANIZED SCHEDULE 10 54 ANSI/ASTM A135 WITH GALVANIZED GROOVED FITTINGS. -10 GLOBE VA. 46" AFF MIN OPEN CELL POLET14YLENE COVER PLATEFOAM OR GALVANIZED SCH 40 WITH GALVANIZED SCREWED FITTINGS BACKERCID NSTALLATION DRY PENDENT DETAIL • ALL ELEVATIONS ARE TAKEN FROM TOP OF PIPE OUTSIDE TO GALV 45 W/RESTRICTED ORIFICE FINISHED FLOOR (ASSUME 0'1 SEAL OPENING WITH ROUT CH G ROME ESCUYGHEONS •FIRE DEPARTMENT VALVES AND DRAINS SHALL BOTH SIDES OF WALL BE READILY ACCESSIBLE AT ALL TIMES. PROVIDE 36" CLEARANCE. •APPLY 810 -STOP 500+ 1/2" THICK ON EACH DRUM DRIP A851" 18LY SIDE OF 1 HOUR AND 2 HOUR RATED WALL ASSEMBLIES. DRY SYSTEM AUXILIARY DRAIN/INSPECTOR'S TEST *HEAD CAGES REQUIRED ON PENDENT HEADS LOCATED IN CEILINGS BELOW 8'0" AFF EXCEPT ON SEMI -RECESSED APPLICATIONS. WHITE HEAD CAGES IN OFFICES AND RESTROOMS RED HEAD CAGES IN ALL OTHER AREAS ®SYMBOLIZES HYDRAULIC CALCULATION REFERENCE POINTS. [+s7'a"] INDICATES ELEVATION ABOVE FINISHED FLOOR ASSUME FFE = D' -D" [as" ] INDICATES ELEVATION DOWN FROM DECK " Cl\SIV rpire SUP TO V L PIPE UP TO 4° IN UNSHADED AREA PIPING LIMITATION PLAN NO SCALE ELEV. 24'6" INSTALLATION PROCEDURE 1, CORE DRILL 2 I/2' DIAMETER HOLE IN THE FREEZER/COOLER INSULATED CEILING PANEL. 2. INSTALL DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION REQUIREMENTS. 3. COMPLETELY FILL ANNULAR CEILING OPENING BETWEEN THE ESCUTCHEON AND TOP OF CEILING PANEL WITH OPE CELL POLYETHYLENE FOAM BACKEPROD. 4. INJECT DOW CORNING 739 PLASTIC ADHESIVE SEALANT INTO THE TOP OF THE FREEZER/COOLER CEILING CORE OPENING IN ACCORDANCE WITH SEALANT MANUFACTURERS INSTRUCTIONS. 8" PIPE - i dG PIPE 4" AND ZGER WITHIN 3" OF ST PANEL POINTS PIPE 6" AND SMALLER MAXIMUM HANGER SPACING FOR PIPES PERPENDICULAR TO JOISTS 4" PIPE 6" PIPE 8" PIPE 12'-0" NOT TRAPEZED NOT TRAPEZED TRAPEZED HANG EVERY OTHER .JOIST HANG EVERY JOIST HANG EVERY JOIST PIPE 3" AND SMALLER - NOT TRAPEZED - MAXIMUM HANGER SPACING PER NFPA 1 1/2" TO 3" PIPE EVERY 15'-0" 1" TO 1 1/4" PIPE EVERY 12'-0" 21-011 PIPES PERPENDICULAR TO JOISTS 8" PIPE NOTE: LEAVE OPEN JOIST SPACE BETWEEN TRAPEZE HANGERS NOTE: DO NOT HANG 2 OR MORE PIPES 4" OR LARGER IN THE SAME JOIST SPACE PIPE 6" AND SMALLER MAXIMUM HANGER SPACING FOR PIPES PARALLEL TO JOISTS 4" PIPE 6" PIPE 8" PIPE 12'-O" 10'-0" 6'-0" NOT TRAPEZED TRAPEZED TRAPEZED PIPE 3" AND SMALLER - NOT TRAPEZED - MAXIMUM HANGER SPACING PER NFPA 1 1/2" TO 3" PIPE EVERY 15'-0" V TO 1 1/4" PIPE EVERY BUILDING SECTION LOOKING SOUTH _ PIPES PARALLEL TO JOISTS **PENDENT HEADS IN CEILINGS III AND ABOVE TO HAVE EXTENDED 401 ESCUTCHEONS **PENDENT HEADS IN CEILINGS 9'-11" AND BELOW TO HAVE SEMI -RECESSED ESCUTCHEONS #1 - I ZONE #2 - 36,458 90. FT ¢rte #3 - 37, qO3 I FT 3jc� #4 - 47,186 SQ. FT Ix WIW r #5 - 48,588 SQ. FT I 1 1 2111686 90. FT I i --- ID' VA_ER �- t r L-> I_ C, (I r I I 1 �■ I I , I I INS C V j` < I I , , Iru IN m £ d I� t D IA i V) -1 � F9 m I I I , I I I , I I I , I 8' WAT R 12' WATER , EXISTIN -- ---------- I L PIPE UP TO 4° IN UNSHADED AREA PIPING LIMITATION PLAN NO SCALE ELEV. 24'6" INSTALLATION PROCEDURE 1, CORE DRILL 2 I/2' DIAMETER HOLE IN THE FREEZER/COOLER INSULATED CEILING PANEL. 2. INSTALL DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION REQUIREMENTS. 3. COMPLETELY FILL ANNULAR CEILING OPENING BETWEEN THE ESCUTCHEON AND TOP OF CEILING PANEL WITH OPE CELL POLYETHYLENE FOAM BACKEPROD. 4. INJECT DOW CORNING 739 PLASTIC ADHESIVE SEALANT INTO THE TOP OF THE FREEZER/COOLER CEILING CORE OPENING IN ACCORDANCE WITH SEALANT MANUFACTURERS INSTRUCTIONS. 8" PIPE - i dG PIPE 4" AND ZGER WITHIN 3" OF ST PANEL POINTS PIPE 6" AND SMALLER MAXIMUM HANGER SPACING FOR PIPES PERPENDICULAR TO JOISTS 4" PIPE 6" PIPE 8" PIPE 12'-0" NOT TRAPEZED NOT TRAPEZED TRAPEZED HANG EVERY OTHER .JOIST HANG EVERY JOIST HANG EVERY JOIST PIPE 3" AND SMALLER - NOT TRAPEZED - MAXIMUM HANGER SPACING PER NFPA 1 1/2" TO 3" PIPE EVERY 15'-0" 1" TO 1 1/4" PIPE EVERY 12'-0" 21-011 PIPES PERPENDICULAR TO JOISTS 8" PIPE NOTE: LEAVE OPEN JOIST SPACE BETWEEN TRAPEZE HANGERS NOTE: DO NOT HANG 2 OR MORE PIPES 4" OR LARGER IN THE SAME JOIST SPACE PIPE 6" AND SMALLER MAXIMUM HANGER SPACING FOR PIPES PARALLEL TO JOISTS 4" PIPE 6" PIPE 8" PIPE 12'-O" 10'-0" 6'-0" NOT TRAPEZED TRAPEZED TRAPEZED PIPE 3" AND SMALLER - NOT TRAPEZED - MAXIMUM HANGER SPACING PER NFPA 1 1/2" TO 3" PIPE EVERY 15'-0" V TO 1 1/4" PIPE EVERY BUILDING SECTION LOOKING SOUTH _ PIPES PARALLEL TO JOISTS **PENDENT HEADS IN CEILINGS III AND ABOVE TO HAVE EXTENDED 401 ESCUTCHEONS **PENDENT HEADS IN CEILINGS 9'-11" AND BELOW TO HAVE SEMI -RECESSED ESCUTCHEONS TYCO ELO-2318 11 VIKING M 8.0 3/4" B 8.0 3/4- 155' MHT W 25 25.2 1" 165' BR PEP L 8181 8.1 1" NPT 200' L 8181 8.1 1" NPT 200' 5.6 1/2" 286' BRASS LEGEND 1. e" UNDERGROUND FEED 2. 8" UNDERGROUND FLANGE 3. PRESSURE RELIEF VALVE - PIPE TO MANIFOLD DRAIN - BY TFP 4. 811 SUPERVISED OStY GATE VALVE 5_ AMES 200055 DOUBLE CHECK VALVE 6. 8"1 GROOVED FLANGE 7. 8" GROOVED q0 8. 8" GROOVED TEE q. 4 INLET FDC W/ CAPS AND CHAINS - SEAL PENETRATION, CHROME ESCI 10. FIRE PUMP - 1500 GPM AT 85 PSI - FEERLE55 11. CONCENTRIC INCREASER 12. PUMP BASE 13. 8" WAFER CHECK 14. JOCKEY PUMP 15. JOCKEY PUMP SUCTION 16. 8" SUPERVISED GROOVED BUTTERFLY VALVE 17. ALARM JUNCTION BOX 18. JOCKEY PUMP DISCHARGE 1q. JOCKEY PUMP CONTROLLER 20. FIRE PUMP CONTROLLER 21. GROOVED REDUCER 22. 8" PUMP TEST HEADER - BY WAL*MART 23. SUPERVISED SYSTEM CONTROL BUTTERFLY VALVE 24. FLOW SWITCH - POTTER VSR-F 25. fol' SUPERVISED BUTTERFLY VALVE 26. TYCO GROOVED RISER WITH TEST/DRAIN VALVE, SIGHT GLASS, PRESSURE GAUGE, AND FLOW SWITCH PIPE TO OUTSIDE - SEAL PENETRATION, CHROME ESCUTCHEONS 27. SPARE HEAD BOX CONTAINING: - EXTRA SPRINKLERS PER NFPA, 13 - HEAD WRENCH FOR EACH TYPE OF SPRINKLER 28. HORN STROBE ALARM 24 VAC NOTE: ALL FLOW, PRESSURE, AND TAMPER SWITCHES TO BE POTTER. ALL PIPING PENETRATING EXTERIOR WALLS TO BE GALVANIZED SEAL PENETATRATI�ONS�AND INSTALL CHROME ESCUTCHEONS ON BOTH SIDES OF WALL. ELEV 15' A==A f ZONE #1 - I ZONE #2 - 36,458 90. FT ¢rte #3 - 37, qO3 I FT 3jc� #4 - 47,186 SQ. FT Ix WIW r #5 - 48,588 SQ. FT I 1 1 2111686 90. FT I i --- ID' VA_ER �- t r L-> I_ C, (I r I I 1 I I , I I C V j` < I I , , Iru IN m £ d I� t D IA i V) -1 � F9 m I I I , I I I , I I I , I 8' WAT R 12' WATER , EXISTIN -- ---------- I TYCO ELO-2318 11 VIKING M 8.0 3/4" B 8.0 3/4- 155' MHT W 25 25.2 1" 165' BR PEP L 8181 8.1 1" NPT 200' L 8181 8.1 1" NPT 200' 5.6 1/2" 286' BRASS LEGEND 1. e" UNDERGROUND FEED 2. 8" UNDERGROUND FLANGE 3. PRESSURE RELIEF VALVE - PIPE TO MANIFOLD DRAIN - BY TFP 4. 811 SUPERVISED OStY GATE VALVE 5_ AMES 200055 DOUBLE CHECK VALVE 6. 8"1 GROOVED FLANGE 7. 8" GROOVED q0 8. 8" GROOVED TEE q. 4 INLET FDC W/ CAPS AND CHAINS - SEAL PENETRATION, CHROME ESCI 10. FIRE PUMP - 1500 GPM AT 85 PSI - FEERLE55 11. CONCENTRIC INCREASER 12. PUMP BASE 13. 8" WAFER CHECK 14. JOCKEY PUMP 15. JOCKEY PUMP SUCTION 16. 8" SUPERVISED GROOVED BUTTERFLY VALVE 17. ALARM JUNCTION BOX 18. JOCKEY PUMP DISCHARGE 1q. JOCKEY PUMP CONTROLLER 20. FIRE PUMP CONTROLLER 21. GROOVED REDUCER 22. 8" PUMP TEST HEADER - BY WAL*MART 23. SUPERVISED SYSTEM CONTROL BUTTERFLY VALVE 24. FLOW SWITCH - POTTER VSR-F 25. fol' SUPERVISED BUTTERFLY VALVE 26. TYCO GROOVED RISER WITH TEST/DRAIN VALVE, SIGHT GLASS, PRESSURE GAUGE, AND FLOW SWITCH PIPE TO OUTSIDE - SEAL PENETRATION, CHROME ESCUTCHEONS 27. SPARE HEAD BOX CONTAINING: - EXTRA SPRINKLERS PER NFPA, 13 - HEAD WRENCH FOR EACH TYPE OF SPRINKLER 28. HORN STROBE ALARM 24 VAC NOTE: ALL FLOW, PRESSURE, AND TAMPER SWITCHES TO BE POTTER. ALL PIPING PENETRATING EXTERIOR WALLS TO BE GALVANIZED SEAL PENETATRATI�ONS�AND INSTALL CHROME ESCUTCHEONS ON BOTH SIDES OF WALL. ELEV 15' A==A f ZONE #1 - 411 741 50. FT ZONE #2 - 36,458 90. FT ZONE #3 - 37, qO3 SQ. FT ZONE #4 - 47,186 SQ. FT ZONE #5 - 48,588 SQ. FT 2111686 90. FT FLOH TEST INFORMATION DATE: 6/16/04 STATIC PRESSURE: 54.2 PSI RESIDUAL PRESSURE: _ J 4_0.6 FLOW: - - 1600 GPM SOURCE OF INFORMATION: ALTERNATIVES IN 1 ENGINEERING DATE 7/10/OS TOTAL A.S. 7853 FLOW TEST INFORMATION PROVIDED AT BASE til= RISER AND DOES NOT INCLUDE LOSS DUE TO BACKFLOW PREVENTER. LOSS DUE TO BACKFLOW PREVENTER 15 INCLUDED IN HYDRAULIC CALCULATIONS. SCHOOL .� BOULEVARD IF' WATER I I I 11 12' WATER 401 OR SEMI -RECESSED ESCUTCHEON ■_ 41TE SEMI -RECESSED ESCUTCHEON 4T 'CHROME 155' COVER PLATE - A DIM = 'WHITE 155• CnVFR PI ATF - CI IT Tn I FA SITE PLAN NO SCALE PIPING PENDENT =>L)Isol 1/2" = 11-011 1 I I t I I I i �p� 13 u N.T.S. 1� W I ilm 11 �p NOR =KIM ' m , tI 1110 � Ri t i L VST1O V S/211 = 1"-011 zLEGEND z -- V 1 3 058Y VALVE (SUPERVISED) LEGEND 2 3 DRY PIPE VALVE U 1 6 OS$Y VALVE (SUPERVISED) z 3 AIR COMPRESSOR - OILLE55 TANK MOUNTED z GENERAL AIR OL33550ACT 1/2 HP 120V 60 HZ w 2 6 DRY PIPE VALVE WITH ACCELERATOR A 00 A O A T 3 AIR COMPRESSOR - OILLESS, TANK MOUNTED iU I- w w4 PIPE STANDS uI 1- 0.r N GENERAL AIR OL1204V200AGT 2 HP 1PH 230V 60 HZ Q 4 5 AUX. DRAIN -Q 4 4 PIPE STANDS 6 AIR MAINT. DEVICE/ z 13 E 5 AUX. DRAIN j Iu K N AIR SUPERVISORY SWITCH POTTER PS40 2A > ul a U1 6 AIR MAINT. DEVICE oL WATERFLOW ALARM POTTER PS10 2A d A 1L n2 u -I- Q - A8 IL AIR SUPERVISORY SWITCH POTTER PS40 2A l4 IL - tu 3 13 d O 37 Lu WATEROPENING RM POTTER PS10 2A DRY SYSTEM VOLUME 220 GAL.GUICK 3u O PITCH DRY SYSTEM VOLUME 923 GAL. DRY SYSTEM TO DRAIN X11 O _ TO DRUM DRIP ASSEMBLY PITCH DRY SYSTEM TO DRAIN Jt3 MAINS 1/4" IN 10'-O" As TO DRUM DRIP ASSEMBLY BRANCHLINES 1/211 IN 10'-O" MAINS 1/4" IN 10'-0" O O BRANGHLINES 1/2" IN 10'-0" PLUG PL FRONT PLUG O O o FRONT VESTIBULE DRY PIPE RISER GARDEN CENTER DRY PIPE RISER ABOVE CORRIDOR 110 CALCULATED X NON -CALCULATED - MAINS TO BE SCHEDULE 10 ASTM A 135 OR DYNAFLOW ASTM A 795 2 4' 6' 8' 10'12'14'16'18'20'22'24'26'28'30'32'34'36'38'40 4244 ' ' ' WET SYSTEM X DRY SYSTEM MAKE OF SPRINKLER SEE HEAD NOTES WITH GROOVED FITTINGS RATED FOR 775 PSI HAZARD SEE CALC NOTES MODEL -GROOVED BRANCHES TO BE SCHEDULE 10 ASTM A 135 OR DYNAFLOW __ TOTAL FIRE PROTECTION N __ HAL -MART SUPERCENTER 9320 CEDAR ST STORE #3624 MN55362 SHOP DRAWING AREA PER SPRINKLER " ORIFICE SIZE ASTM A 795 WITH GROOVED FITTINGS RATED FOR 175 PSI DENSITY K -FACTOR - SCREWED BRANCHES TO BE SCHEDULE 40 ASTM A 735 WITH SCREWED Vi,L DRAWN BY BLF SHEET N DATE 7/10/OS TOTAL A.S. 7853 FP 4 OF a �- L-> I_ C, (I tp to V j` < C14y k1 zLEGEND z -- V 1 3 058Y VALVE (SUPERVISED) LEGEND 2 3 DRY PIPE VALVE U 1 6 OS$Y VALVE (SUPERVISED) z 3 AIR COMPRESSOR - OILLE55 TANK MOUNTED z GENERAL AIR OL33550ACT 1/2 HP 120V 60 HZ w 2 6 DRY PIPE VALVE WITH ACCELERATOR A 00 A O A T 3 AIR COMPRESSOR - OILLESS, TANK MOUNTED iU I- w w4 PIPE STANDS uI 1- 0.r N GENERAL AIR OL1204V200AGT 2 HP 1PH 230V 60 HZ Q 4 5 AUX. DRAIN -Q 4 4 PIPE STANDS 6 AIR MAINT. DEVICE/ z 13 E 5 AUX. DRAIN j Iu K N AIR SUPERVISORY SWITCH POTTER PS40 2A > ul a U1 6 AIR MAINT. DEVICE oL WATERFLOW ALARM POTTER PS10 2A d A 1L n2 u -I- Q - A8 IL AIR SUPERVISORY SWITCH POTTER PS40 2A l4 IL - tu 3 13 d O 37 Lu WATEROPENING RM POTTER PS10 2A DRY SYSTEM VOLUME 220 GAL.GUICK 3u O PITCH DRY SYSTEM VOLUME 923 GAL. DRY SYSTEM TO DRAIN X11 O _ TO DRUM DRIP ASSEMBLY PITCH DRY SYSTEM TO DRAIN Jt3 MAINS 1/4" IN 10'-O" As TO DRUM DRIP ASSEMBLY BRANCHLINES 1/211 IN 10'-O" MAINS 1/4" IN 10'-0" O O BRANGHLINES 1/2" IN 10'-0" PLUG PL FRONT PLUG O O o FRONT VESTIBULE DRY PIPE RISER GARDEN CENTER DRY PIPE RISER ABOVE CORRIDOR 110 CALCULATED X NON -CALCULATED - MAINS TO BE SCHEDULE 10 ASTM A 135 OR DYNAFLOW ASTM A 795 2 4' 6' 8' 10'12'14'16'18'20'22'24'26'28'30'32'34'36'38'40 4244 ' ' ' WET SYSTEM X DRY SYSTEM MAKE OF SPRINKLER SEE HEAD NOTES WITH GROOVED FITTINGS RATED FOR 775 PSI HAZARD SEE CALC NOTES MODEL -GROOVED BRANCHES TO BE SCHEDULE 10 ASTM A 135 OR DYNAFLOW __ TOTAL FIRE PROTECTION N __ HAL -MART SUPERCENTER 9320 CEDAR ST STORE #3624 MN55362 SHOP DRAWING AREA PER SPRINKLER " ORIFICE SIZE ASTM A 795 WITH GROOVED FITTINGS RATED FOR 175 PSI DENSITY K -FACTOR - SCREWED BRANCHES TO BE SCHEDULE 40 ASTM A 735 WITH SCREWED AREA OF OPERATION TEMP. RATING FITTINGS RATED FOR 175 PSI HOSE ALLOWANCE " C -FACTOR OVERHEAD 120 140 U.G. PIPE AND FITTING TYPES CHECKED BY: DTSI DRAWN BY BLF SHEET N DATE 7/10/OS TOTAL A.S. 7853 FP 4 OF BARS 7'" 7'-8 1/2"� -6 4'-0 3/4" 1-- 13'-6 3/4" -�- 11'-7 1/2" --I-- 13'-6 3/4" 3'-2 1/4" 46' OUT TO OUT BASE 46'-2 1/2" OUT TO OUT PANELS WAPMART SUPERCENTER PROTO-TYPE 195-2004 HOUSE #2 LIFTING WEIGHT: 29,900 Lbs. I ff 9 "Z• \ WQ 709 SIGMAN ROAD CONYERS, GA 30013 PH: (770) 285-3100 FX: (770) 285-3076 Ki/I PHOENIX 195-2004 HOUSE GIM T Hill PHOENIX Store / Cust: WAL*MART 195-2004 SUPERCENTER Pae 4 of 4 709 SIGMAN ROAD Location: MONTICELLO, MN g CONYERS, GEORGIA 30192 Store #: 3624 Original issue date: 12-30-04 HOUSE2 RACK D (770)285-3100 Fax: (770)285-3076 Job #: MS27791 (DANFOSS) # /I Printed on: 12-30-04 Proto Directory. 4-30-04 Prepared By: PHILLIP HERBERT Date: 7-30-04 Field Connection:X❑ Horizontal, Vertical Rev. Date By. Revision: A 4-21-05 CP Chanced D4 from 40' of Beer to 24' WAL-MAR T Stores Inc. 11/17/04 Sys No Size Model Heat Exchr. Expon Valve Dist Noz Application MBTUH SST Type Of Fans 'F Defrost m s o s Defrost Refrig. Valves m s Volts/0 Liquid Suction Suction Est. Trunk Trunk Bran lent Horiz Riser Horiz Bran Riser Liquid Main Bran. D1 36' N6DL � ,ZQWPZ W ZZ�w PRODUCE W MISTERS 57.0 +19 OC 5.4 1 115/1 ME19 SORIT20 249 2 1/8 1 5/8 7/8 D2 36' N6DL [):f O� 0 PRODUCE W MISTERS 57.0 +19 OC 5.4 1 115/1 ME19 SORIT20 173 2 1/8 1 5/8 7/8 3 84x1 2 013 Ljg2 0 G C E T DLI C OE +OE C 8 2 8 1 4 8 1 E 4 0IT0 2 11/5 Z D4 24' * 6 1-U C) 0 M DBE 36-0- +21 C 3. 115 1 M 1 S RIT20 1 4 1 5 8 ** 1 1 8* * 7 8 3 5 8 5 M A 0. + 0 0 .0 11 E 4 0 1 0 2 1 8 D6 24' 05DM M D DAIRY 34.3 +20 OC 4.0 115/1 ME14 SORIT20 125 1 5/8 1 1/8 7/8 D7 22x62x11 2 ADT312AJ HXR250A SSSE 4C L 3 2/3 DAIRY COOLER 61.6 +25 OC 21.6 115/1 ME19 SORITI5 186 2 1/8 1 3/8 11/8 7 8 1/2 D8 22x62x11 ADT312AJ HXR350A SSSE 4C L 3 113 DAIRY COOLER 30.8 +25 OC 10.8 115/1 ME14 SORITI2 166 1 5/8 1 1/8 7/8 D9 6x52xl1 3 SM090A HXR75 EGSE 1C L 1 DAIRY COOLER 26.4 +25 OC 12.6 115/1 ME9 SORITI2 235 1 3/8 7 8 5/8 7 8 1 2 D10 24' 05DR M D REAR LOAD DAIRY 34.1 1 +201 OC 5.0 1 115/1 ME14 SORIT20 225 11 5/81 11 8 7 8 D11 20' 05DR M D REAR LOAD DAIRY 28.4 +20 OC 4.5 1 115/1 ME14 SORITI5 262 1 5/8 1 1/8 7/8 D12 2' 05DM M D DAIRY 17.2 +20 OC 2.0 115/1 ME6 SORITI2 277 1 3/8 7/8 5/8 D13 SPARE 1 5/8 7/8 *REMODELED LINEUP ****NEW PIPING Model No: jPs425SMRAD 1 2 3 4 RACK D 5 6 7 General Specifications Discharge Refrigerant Type R -404A I Manifold Size 2 1/8 Liquid Line Size 2 1/8 Compressor 06DR725 06DM337 06EM450 06EM775 Suction Tem +19 1 Oil Separator 927 Manif Size 2 5/8 Kit Number Sat. Suction Temp. - I Disch. Check Valve 2 1/8 Drier Sig. 4 CORE 21/8 Capacity MBTUH 74.9 114.1 139.6 217.7 Condensing Temp 115 Disch. Regulator N/A Master Sol N/A Suction Temp. +19 +19 +19 +19 Outside Air Temp. 100 Bypass Regulator ORD -4-20 Drain Regulator A8213-2 1 8 x 2 5/8 Horsepower/RPM 6.5 10 15 25 Re 'd. MBTUH Main 464.8 Main Cond. Supply 21 8 Sure Solenoid ME42 RLA LRA 14.1/80.0 19.9/114.0 33.91/150.0 45.7 210.0 Re 'd. MBTUH Sat. Main Cond. Return 2 5/8 Sure Ball Valve 21 8 Circuit Breaker 20A 30A HH83XB695 HH83XB607 Avail. MBTUH Main 546.3 Sure Check Valve 1 8 Contactor 25A 125A 40A 50A Avail. MBTUH Sat. Heat Reclaim -2 Wire Size AWG 12 #10 #8 #6 Subcoolinq factor Kit Number Receiver Head Fan NO NO NO INO Total Re'. Heat MBH 785.5 Water Air Horiz Vert HORIZONTAL Crankcase Heater YES YES YES YES ADJUSTED THR - Heat Reclaim Valve Dia. x Length 14 X 108 Unloader 1 STEP- - ids Defrost MCA 208 Isol. Valve To Lbs Q 90% PD 490 Desu erHeat Valve NO NO NO NO Eva orator MCA 208 Isol Valve From Desu erHeat Sol NO NO INO INO Notes Condenser/Split 50 50 - Suction 1 2 3 * 3/8" FILTER IN OIL RETURN LINE OFF OIL RESERVOIR Model # BRX118 10 FPI Suc. Tem +19 * ALL SOLENOID VALVES TO HAVE SCHRAEDER VALVES ON OUTLET T.D. 14.5 830 RPM MOTORS Line Size 3 1/8 * 3/8" CHARGING VALVE LOCATED ON SUCTION AND LIQUID LINES PRIOR TO DRIER OR FILTER FLA 19.2 460/60/2 Manif. Size 3 1 8 * MOUNT SIGHT GLASS VERTICALLY Max. Overcur Prot. Filter 5" BRS 3 8 * DANFOSS OIL PRESSURE CONTROL - MP54-06OB2008 HP #10312 Weight Accum. A-12318 * DANFOSS HIGH PRESSURE CONTROL - KP713-060-2004 HP 11060-1 inverter - - Notes * DANFOSS LOW PRESSURE CONTROL - KP2-060-20i3 HP #10438 Solenoid (2)OE-42 2 OE -42* X55 -CRO -6-80 200 TO BE INSTALLED IN Isol. Valve To 2 1/8 2 1/8 SORIT PILOT LINE ****USE ONLY VIRGINIA KMP EMKARATE LE681-11 POE OIL WITH CARLYLE RECIPROCATING COMPRESSORS**** Pump Out Sol. E3S120 N/A Isol. Valve From 1 5/8 15/8 Check Valve From 1 5/8 15/8 MOTORIZED INTAKE LOUVERS (3) SPLIT VALVE 42' DDDR DOS caw Dt cac tt wKc m caw w ACC I RACK - D MANIFOLD I 37 1/2'WD X 24'DEEP X 39'TALL BRX-118 I DEFROST TO CONDENSER 14'-6 3/4" TERMINATION (APROX.) R',AC,K D N 0 o FROM CONDENSER /I CIRCUITS ® D13 -D1 6 8,-5„ 8'-7" �'O •o•o•o •o•o•o •o•o•o116.0,0 Z RACK - D PIPE ASE 4'-6" TYP. 7 - 6 -� OUT TO OUT BASE 7'-8 1/2" OUT TO OUT PANEL T-9" 9'-3 3/4" •o.o•o = CIRCUIT STUB WINDOW - 1'-6 3/4" W X 6" H ®= FIELD ELECTRICAL PENETRATION WINDOWS AS PER LABELED - 1'-6 3/4" W X 6" H ACC = ACCUMULATOR DOS = DISCHARGE OIL SEPARATOR SUB = SUBCOOLER 112.5 KVA 480V INTAKE 480V MAIN TERMINATION EXHAUST FANS LADDER STANDBY POWER PANEL CH PANEL TERMINATION F 6" 10" JWALL POST 4W 1/2" WIDE DO NOT PENETRATE 3'-6" 46' OUT TO OUT BASE ACC caw ct cmc a taw ra � u noS u - RACK - C I RACK - C MANIFOLD I SPLIT VALVE BRX-102 DEEIROMST TERMINATION RACK C CIRCUITS /� _16 C18 -C1 •o•o•o •o•o•o •o•o•o •o•o•o •o•o•a •o•o•a NTAKE RACK - C PIPE CHASE 5'-1" 10" - 29'-5 1/4" 33'-3 3/4" - 4'-3" W N OQ �O0, 0 W�VwIQZ2w� 20 W zmm-�zao�`uJi-z QQ�O4�ilOdK V wKwV o:y f-"Omr ztna> L� Z a��Q�w'oo�awww� O 3wzw�'z ywwazOoz H Oo.�V010 z0 <p2acc J QQC �Nwm�E To K 000n �Z FFW .MxU Kx a_ OF-KF52K'0F= ~ NSN��ZOq OZ W4WW00 !n V-O�`3QQJIiQU1Q(C(YQI- ISSUE BLOCK ZU) o 11/17/04 a O�<� 4 FILE NAME: Fr''oow ooz C.C.D. #8 �waN� 1 4Z a --i w 05/04/05 ��MMO F>,. -; E3 WzagN'A'X Z 0"'"mxY�" Zw � ...w Owxwa= � ,ZQWPZ W ZZ�w Z v ISSUE BLOCK �. 11/17/04 C.C.D. #2 FILE NAME: 01/24/05 C.C.D. #8 Q 05/04/05 C.C.D. #17 C� ., 0 Ct N � H o Li P [):f O� 0 C/) rn w o� Z C) 0 ISSUE BLOCK �. 11/17/04 C.C.D. #2 FILE NAME: 01/24/05 C.C.D. #8 Q 05/04/05 C.C.D. #17 CHECKED BY: lvkD DRAWN BY: AWS FILE NAME: R4 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 REFRIG SCHEDULES SHEET: R4 MOUNTING BRACKET PROVIDED WITH LIGHT FIXTURE TYP. SECURE MOUNTING BRACKET TO TRUSS AND LIGHT PER MANUFACTURER'S RECOMMENDAI WEATHER PRO JUNCTION BOk PROVIDE WATE CORD CONNEC 6' CORD PRO\ FIXTURE. COI CORD AROUNE CLOTH TRUSS THE SHADE CLOTH LIGHT FIXTURE COMES PRE—ASSEMBLED WITH 6' CORD. ATTACH FURNISHED MOUNTING BRACKET TO FIXTURE AND TRUSS PER THE MANUFACTURER'S RECOMMENDATIONS. DO NOT DRILL OR PENETRATE FIXTURE , ini +�,n,n ,r rniri ,nr ,.,ni ,c-u,n ,� nrurrn a rrn nn n e u n nrn 2 NTS 08.29.03 EL08 14 13 12 11 E5 +14'-0" € € d+14'-0" P , TYP +16'-0" TYP I I r UNLESS NOTED OTHERWISE fit z n 4'— f l 12'-4" n 12 TIRE SALES TYP 2 _fiK MOUNT ON FACE OF 1 RACK TYP OF 2 27 6illi, f A TYP 16.026 TYP OF 5 E1.2 5 } 6 OUTSIDE g 55 BAG GOODS 38 f' l� it ll INSIDE 44 4 1 VERIFY EXACT P' l SALES TY LOCATION AND AIMING WITH STORE ll $ PLANNING SETUP SUPERVISOR TYP 9 } f ft ._.7..._ � ..., ..... Ile ._.d.+..._ +_'1 R mY i r sz m �joN H2P i 6 PART 2/2) € P dt 'u L17 Z C`YP OF 81 CONDUIT ON OF SHADE i TRUSS H1 TYP OF 3 N12 7 I C _6 7-7 +14-0 n N d D (D 2 Q I, 27 i A J j ABJ I cv ! # I - f4RJ= 12 TYP OF 3 C s ABJ — _ — _ — _ _ —1..—. _ « — _ — _ — _ 2 a' d � AI�JABJ g; I PP 3 ABJ=.`, P P P P P P P P PV P P P s®s 3 ;�- H1 R, fi H �, 1;i 1D 25 D C:' i TYP 1 s� .� 27 � �€t6 �.. " �_ , _ ABJ P. i t"`r" 17 .s 2 Y i!"? i' �, i b- - 1: }61 �s P O4 p 2't j P 2 P j P P `2 P + �• . � _ rn� � :m.�..,ms._ ms`s -� . Y!x�§�4 .,'= '.-'-rem — � .,. 7 . � .. ... _. ,.. �^-_ ..._ ! I i P 29 P—, —P P d P TYP P 23 29 ; 5 '(1 17 23 3 1 21 23 27 29 E 5 9 i 11 15 { 171 23it—P P d 2i +' P P i LL j 11 17 ! 23 L NI1P-2 3 = ¢¢ I� 22P i3 �9 3 9 15 F 21 !' 1 7 ; H1P1 H1P1 # fi 1 7 13 19 2 H1P2 H1P2 H1P2 d H1P2 6d6 t P it ff 1 4d iIT I,r P g{ E t �rd d I. _ _ 1 P 2 d� < P II ? J i f t w lotP k i 9 ± I P i I j 15 I i I ofP x TYP ma! I { + p�P 5 i TYP SALES 26 3 i i GROCERY SALES166 gE € } I ! P 13 1 € �f'fYP d TYPP. r t g € t t , � i P 5,_4•'_1•• 7 5„ 5, 5'€ i7„ 6, 6'd45" 16'-0" 16'-0" 0'-5"'I 15'-6" 15'-6" 8'-1'` 15'-6" 15'-6" —3' 16'-0" 16'-0" 10'-0" 15'-0° 9'-8"= 15'-0" 15'-0" 10'-11" 15'-6" 15'-6" —1' 16'-0" 16'-0" 0'-7"I 16'-0" 16'-0" 110'-5' 16'-0" 16'-0" 13'-5" 16'-0" 16'-0" 9'-7"1 16'-0" P Lo d o ! H1P1 H1P2 1T-9 co I f1 ® 35 i P 3 H1P1 37 P �.. E ., F_ P P P _.._,_fi......,P TYP ® IBI `5 fBfG 37 39 p € 21 31 35 3739 39 ! TYP OF r^ — 48 1€mTYP p�s 91 2Q2 i F i k S E 1 i - E r l d oy E i N 7 75€ P_. I O ( dS CIRCUITED J J RH4(. 2 i P !P13 i Iti1 i I? 1, P n TYP , - E1.23 a I OUICIDE ° ARY 1/2) ' I :� 1 LIVE GOODS i I (\J( ' l h ,I I , f � r , f , r 3 _ a , �a j �._ \d � ,... ? �..A..,.,ahr✓+.<erhl'�.,r✓rr.'ti.,.n._ >.r" ! —s• NOTE: LIGHT FIXTURE LOCATIONS IN GARDEN CENTER SHALL BE COORDINATED WITH RADIANT HEATING SYSTEM 4 MANUFACTURER'S RECOMMENDED MINIMUM CLEARANCES MUST BE MAINTAINED REF MECHANICAL &_ LIGHTING PLAN E 2� y i 3 E1= TYPE 2 d E1.1 n i TYP OF ROW tU l[ l g3 20 1 xQ26 # _ s u f ! 12 i , _H2P _ .- .... ...", '.biiY^silo.' _ .'i6. . ve9hl-aID"$dffiSF_�._,,. .....i..� ....� (1 .,. a�...m,............_®......., ...—....e» .®. I i i 1 1 20 P B' P 26 P ASSEMBLY USPENDED —1 A . AI v1ING WITH STORE KANNIN LJ G O a d I d I I I d d d 3dy gig 9 i d d I � i ! 3 d i F F- 71 I 1 d I I fi I d � d d d I d I � I L_ _J , —MOUNT -5'-0" FROM SOFFIT, SUSPEND FROM STRUCTURE TO +16'-6". TYP OF TYPE 26 PERIMETER FIXTURES ONLY REF ARCHITECTUR.a_ B.6 TYP OF 6 I 3 r �r 1 `�{ySf N yyyy F' j auuw-vvwv�.a":xsrr.^vuc^a.-,�-uewva�= 4 1 ; UNISTRUT LIGHTING SUPPORT SYSTEM. CONTACT KEITH DAVIS OF 1 g UNISTRUT MIDWEST CONSTRUCTION GE1 I SERVICES AT (913) 495-9812 FOR P ORDERING AND DELIVERY. NOTE: p s 1 ! E1.1 w O< 00, w Z^OK¢OFN Zof NZ a a QQa$o wn1w wo w d`n�OGU~w¢K�Ndm Oa aNwLLNO�ow�Noo'�o�w'c�aoi a°ooZoLLoZaozwa�aZ jFJm�aW� mz bl�i MW 3F5�`N Mez`MwW'<F! E z'v, o 10/22/04 OaZov E ��oow �Wa0 000 C.C.D. #2 CW rx E�Qoa�; �a���_w Z O�Q:x Ymrnz a zC�o=<�x= C" (s) W zZw U) �� 0 ZW~� U � E 10 ISSUE BLOCK `\ 10/22/04 C.C.D. #1 11/17/04 C.C.D. #2 PROTO CYCLE: rx C.C.D. #8 08/11/04 ® C" (s) 0 c) � w Q 00 r� a. � O w In 0: 0 LLJ Z �rn m U HOW F a \\ 0'z V) ��zww 10 ISSUE BLOCK `\ 10/22/04 C.C.D. #1 11/17/04 C.C.D. #2 PROTO CYCLE: ,01/24/05 C.C.D. #8 08/11/04 Nz} � w Q 00 QO I— o awaW w In 0: 0 Z �rn m U CHECKED BY: z� w 00 � DRAWN BY: FILE NAME: E1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 O U z� w 00 � UroO U Nz} � w Q 00 QO I— o awaW w In 0: 0 Z �rn m U HOW F a \\ 0'z V) ��zww N n.Q JZ U Q Z Z 4 O p � wa \ i L. - m f- S 0 Z wC)Mww Waio~z Q a— Z LIGHTING PLAN SHEET: E1 3 Y 01 ABJ VISION CENTER EXAM ROOM EL `f 1 /2"=1'-0" 02.27.04 MAN INA i� AT STRUCTURE FOR FUTURE i J BANK. PROVIDE 3/4" tai CONDUIT TO PANEL H2P I ;a i( li4 FUTURE �! BANK 3 i i irl !i CASH COUNTING� i. I H2P 22 i+ + PI EVC01 TYP I STEM MOUNT 2'-0" BELOW FINISHED CEILING 27 16.022 8 27 TYP OF 3 j 3 i E $ i i I , i � f i Li I i = N � i U' wi TYP OF 7 16.023 CHECKOUT (PART. 1/2) 16 H2P--*— 18 i +22'-0" PHARMACY s + + (PART. H2P i l i PRETESTfi WAITING AREA 111 I l 3 3 D i 9 4 ._� EXAM #1 i 16.451 ,w I i� IW 0 78 KEYNOTES 16.021 IN AREAS WITH FENCE: ROUTE CONDUIT DOWN FENCE POST AND MOUNT BOX TO POST. IN AREAS WITHOUT FENCE: MOUNT BOX TO BACK OF SHELVING RACKS. 16.022 INSTALL FLANGE TRIM AND SWING—OUT BRACKET ASSEMBLY FURNISHED WITH FIXTURE. PROVIDE 1-1/2" SPACING BETWEEN CONTINUOUS ROW FIXTURES TO ALLOW FOR PROPER INSTALLATION OF FLANGE KIT. 16.023 REFER TO ARCHITECTURAL DETAIL FOR SOFFIT LIGHT FIXTURE INSTALLATION. 16.220 INSTALL PREFABRICATED ELECTRICAL DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR INFORMATION PURPOSES ONLY. THE ENTIRE ASSEMBLY WILL ARRIVE COMPLETELY PRE—WIRED AND IS AN ETL LISTED ASSEMBLY. 16.451 PROVIDE EMT WITH PROPERLY INSTALLED COMPRESSION OR SET—SCREW TYPE FITTINGS AND AN INSULATED EQUIPMENT GROUNDING CONDUCTOR FOR ALL RACEWAYS SERVING THIS ROOM TO COMPLY WITH NEC, HEALTH CARE FACILITIES. w u}Ji oa oo� i�aoy z� z � 4ap°do�paw Urc�w� 0.W LLf1ZW412-6� W 00] Z a�c+a5->opra-www p 3�zw�'�yww�zO�z u'�wra�voa¢zz¢ Q gNJOJ yZZ41�d O�/1Ua06 J �IaJ NK`Z WCSU�U _?NJ a pO�~~4 ¢¢r5 x¢N2O2� �i ZU) O W OFdYN N FILE NAME: r p O O w cnwa�N PROTO CYCLE: I I z o �ss=~fY. E,3wzoo-. � aYmwz Q (11 w Vjj�W Xwx �F.Uwzrw� D � w �� �° xw--z� m o U U J �i ISSUE BLOCK 71// 22/04 C.C.D. #1 05/05 C.C.D. #6 CHECKED BY: OCV � O W F a FILE NAME: rter',' �i PROTO CYCLE: 062504 o 08/11/04 J V)zd zJ a W = J W Q Q 0 _ 0 J aw¢W p V) �° z rx U - Q J w as ~a~0o z Of Z Z �1 0 ISSUE BLOCK 71// 22/04 C.C.D. #1 05/05 C.C.D. #6 CHECKED BY: DRAWN BY: FILE NAME: E1.1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 Of 0 F- 00 zW w 00 � U}EO E z O J V)zd zJ a W = J W Q Q 0 _ 0 J aw¢W p V) ��0 z =maw S U - Q J <orW i<=Z¢ ~a~0o �wpzvi Of Z Z Q J of�a-< V < 2:MLJ Y�OOWQ � m�>co Z wir (if ww FD SOW w�F- uJ m Qz ¢ w z 0 m Of 0 n ENLARGED LIGHTING FLANS I SHEET:1 . 1 e. LIGHTING FIXTURE SCHEDULE NOTE: ALL FIXTURES AND LAMPS ARE FURNISHED FOR INSTALLATION BY THE CONTRACTOR UNLESS NOTED OTHERWISE ON THE DRAWINGS. TYPE VENDOR CATALOG NUMBER VOLTS WATTS LAMP (PHILIPS) MOUNTING 05.28.04 DESCRIPTION ORDER NUMBER QTY 1 LSI S-232-2-SSO-LM-LD-DL-CHI2-JP 277V 277 114 F32T8/TL841PLUS/ALTO 4 SURFACE 8' STRIP 2 LSI S-232-SSO-LM-LD-DL-CH12-JP 277V 277 58 F32T8/TL841PLUS/ALTO 2 SURFACE 4' STRIP 3 LSI EGS-50-232-SSO(HL)-LM-WL(C&H)-MB-SL-JP-277V 277 79 F32T8/TL841PLUS/ALTO 2 SURFACE 4' SEALED STRIP W/CORD 4 LSI F 232 32 2 SSO-LM-LD-DL-JP 277V 277 114 F32T8/TL841PLUS/ALTO 4 SURFACE 8' INDUSTRIAL. 5 LSI OFM2 WB 400 MH F MT PLP 277 480 MH400/U/M 1 REF DETAIL FLOODLIGHT W/SLIPITTER U FNOT rsF-67 EGS-20-232-SSO-LM- WL -MB -SL -JP -120V 120 58 F32T8/TL841PLUS/ALTO 2 WALL 4' SEALED STRIP LSI NWW-232-SSO-LM-WH DL EQ JP 277V 277 58 F32T8/TL841PLUS/ALTO 2 RECESSED 1' x 4' TROFFER 8 LSI 1TGA-232-SD-SSO-LM-DL-EQ-JP-277V 277 58 F32T8/TL841PLUS/ALTO 2 RECESSED 1' x 4' TROFFER 9 LSI LA-432-SD-SSO-D(HL)-LM-DL-EQ-JP-277V 277 120 F32T8/TL841PLUS/ALTO 4 RECESSED — 2' x 4' TROFFER 10 LSI LA-232-SD-SSO(HL)-LM-DL-JP 277V 277 79 F32T8/TL841PLUS/ALTO 2 RECESSED 2' x 4' TROFFER 11 LSI GBWS 3 175MH F MT PLP 277 215 MH175/U/M 1 WALL SECURITY LIGHT 12 LSI DMR -40 -90 -INC -120 120 90 90PAR38/HAL/FL28 1 WALL DOCK LIGHT 13 ISOLITE SLX60-D-R-20-BK-P N/A N/A N/A N/A STEM / CEILING EXIT SIGN (DOUBLE FACE) 15 ISOLITE SLX60-S-R-20-BK-P N/A N/A N/A N/A STEM / CEILING EXIT SIGN (SINGLE FACE) 16 ISOLITE SLX60-S-R-20-BK N/A N/A N/A N/A WALL EXIT SIGN (SINGLE FACE) 17 LSI LSI-JSE18-2(XA)-AD 277 36 6V, 6W SEALED HALOGEN 2 WALL EMERGENCY LIGHT 18 LSI LSI-JSE54-2(XE)-AD 277 36 6V, 20W SEALED HALOGEN 2 WALL EMERGENCY LIGHT 19 LSI LSI-JSE54-2(XE)-AD 277 36 6V, 20W SEALED HALOGEN 2 STEM EMERGENCY LIGHT 20 LSI WM-232-2-SSO-PM3CO-LM-CH11-JP-277V 277 114 F32T8/TL841PLUS/ALTO 4 REF DETAILS 8' STRIP - PERIMETER 21 LSI WM-232-2-SSOD-HL-PM3CO-LM-CH11-JP-277V 277 149 F32T8/TL841PLUS/ALTO 4 REF DETAILS 8' STRIP - MASTER 22 LSI WM-232-2-SSOD-PM1(5)-LM-CH11-JP-277V 277 149 F32T8/TL841PLUS/ALTO 4 REF DETAILS 8' STRIP - SLAVE 26 LSI S 232-2 SSO LM SR45-2-277V 277 114 F32T8/TL841PLUS/ALTO 4 REF DETAILS 8' STRIP - SOLID SYM REFLECTOR 27 LSI LSI-JSE27-0-AD-REM 277 36 FURNISHED W/FIXTURE 2 WALL EMERGENCY LIGHT - REMOTE HEADS 37 LSI LSI-KSE54-2(XE)-F-AD-CBKT 277 36 6V/20W SEALED HALOGEN 2 STEM EMERGENCY LIGHT -DAMP LOCATION 38 LSI LSI-KSE36-0-F-AD-CP4 W/EF1 :- 3fi 6V/12W 2 WALL EMERGENCY LIGHT -DAMP LOCATION 4 NOT USED 42 LSI EGS-50-232-SSO(HL)-LM- WL -MB -SL -JP -277V 277 79 F32T8/TL841PLUS/ALTO 2 SURFACE 4' SEALED STRIP 44 NOT USED 46 LSI WAL7389-01-BK 277 W/047-605 LMP 277 130 MHC100/U/M/3K 1 PENDANT SPOTLIGHT (BLACK) 50 LSI GB-85W-QL-120-BRZ 120 96 QL85LP 1 SURFACE ENCLOSED FREEZER LIGHT 67 LSI 128 -MH ED -1 -70 -C73 -277 -LP 277 90 MHC70/U/M/3K 1 RECESSED DOWNLIGHT 68 LSI 208-CFLH-226-CL-BAFF-UNIV-SLTPH 277 70 PL -C 26W/41/4P 2 RECESSED DOWNLIGHT 70 LSI DRS-SP-15OMH-F-MT-PLP with BKA-DRS2- WM-4-PLP 277 175 MH150/U/M 1 SURFACE FLAGPOLE FLOODLIGHT LIGHT FIXTURE TENON SLIPFIT WELD POST TOP ADAPTERTO METAL PANEL POST. REF ARCHITECTURAL DETAILS 5 SCALE: NTS ,LTITE CONNECTION JUNCTION BOX METAL WALL PANEL LIGHT FIXTUREFINISHED FLOOR 4�NTS 20" in 01.30.04 F109 LIGHT FIXTURE REFER ARCHITECTURAL FOR MOUNTING DETAIL #16/3 SJ CORD AND PLUG FURNISHED WITH FIXTURE RECEPTACLE AS SHOWN ON PLANS PROVIDE 1 1/4" FENDER WASHERS TYP SLIDING HANGER FURNISHED WITH FIXTURE TYP �\ TIGHTEN FURNISHED HANGER SCREW TO SECURE HANGER TO FIXTURE TYP - PROVIDE 1/4" HEX HEAD BOLT NUT AND LOCK WASHER TYP m ATTACH AND ALIGN FIXTURES USING SCREWS, ANCHORS AND/OR TABS FURNISHED WITH FIXTURES PROVIDE BEAM CLAMP TYP 3 } NT' NTS WAL*MART SIGN BOTTOM CHORD PROVIDE FLANGE CLIP OF BAR JOIST -\(CADDY M24S OR EQUAL) NUTAND WASHER SLIDING HANGER FURNISHED WITH FIXTURE TYP TIGHTEN FURNISHED HANGER SCREW TO SECURE HANGER TO FIXTURE TYP BAR JOIST -LIGHT FIXTURE JOIST GIRDER PROVIDE 2%2%3/16" ANGLE IRON (2 PER SPAN) BEAM CONTRACTOR HAS THE OPTION CLAMP ON BOTH ENDS TO USE EITHER METHOD OF INSTALLATION SHOWN FIXTURES SHIPPED FULLY ASSEMBLEDWITH ELECTRICAL & MECHANICALCONNECTORS FOR CONTINUOUS ROWMOUNTING 05.25.01 EL05 ATTACH AND ALIGN FIXTURES USINGSCREWS, ANCHORS, AND/OR TABSFURNISHED WITH FIXTURES \t BAR JOIST�\ TYP \ FLANGE CLIP (CADDY M24S OR EQUAL) NUT AND LOCKWASHER PROVIDE 1 1/4" FENDER WASHERS TYP SLIDING HANGER FURNISHED WITH FIXTURE TYP TIGHTEN FURNISHED HANGER SCREW TO SECURE HANGER TO FIXTURE TYP PROVIDE 1/4" HEX HEAD BOLT, NUT AND y LOCKWASHER TYP J CONTRACTOR HAS THE OPTION TO USE EITHER METHOD OF INSTALLATION SHOWN FIXTURES SHIPPED FULLY ASSEMBLED WITH ELECTRICAL & MECHANICAL CONNECTORS FOR CONTINUOUS ROW MOUNTING SALES FLOOR LIGHTING NTS 05.25.01 EL02 BOTTOM CHORD OF BAR JOIST BLANK MALE CONNECTOR AND DECORATIVE END CAP AT END OF EACH ROW FURNISHED WITH FIXTURE— SLIDING HANGER FURNISHED WITH FIXTURE TYP TIGHTEN FURNISHED HANGER SCREW TO SECURE HANGER TO FIXTURE TYP 2 #10 (CKT. #32) 1 #10 GND 2 #10 (CKT. #32) IN 1"C2 #10 (CKT. #40)2 #10 -(CKT.IN �10C GND (PART.1/2) 1 #10 GND 40 IN 1"C. J`—SITE LIGHTING (PART. 2/2)\36 PENETRATIONREF 1-E2.4 2 #10 (CKT. #36) (PART. 40/2) 36 40 (PART. 2/2)2 10 CKT. 36 1 #10C GND 2 #10 (CKT. #32) H1P21 #10 GND H1P2 32 �2 #10 (CKT. #32IN C GND #)IN 1"C.�2 #10 (CKT. #40)1 #10 GND 2 #10 (CKT. #36) �2 !j#10 (CKT. #36) IN 1"C. 2 #10 (CKT. #40) 1 #10 GND ra 1 #10 GND N 1 "C. IN 1"C. REF CIVIL SITE PLAN FOR FIXTURE TYPE AND LOC TE LIGHTING PLAN RECEIVE 1/15/0 2 #10 (CKT. #36) 1 #10 GND S 2 #10 (CKT. #36) 1#10 GND IN1"C. 2 #10 (CKT. #33)2 #8 (CKT. #17) 2 #10 (CKT. #1) 2 #8 (CKT. #25)2 10 CKT. 132 X10 ((CKT.33� 5 H2P H2P 17 2 #6 (CKT. #21)131 ?6 GNDT. #29)2 #8 (CKT. #5) 9 2 #8 (CKT. #9) 33 (PART.2/2) IN 1-1/4"C. ML1 #8 GND (PART. 1/2) IN 1"C SITE LIGHTING��f-SITE LIGHTINGPENETRATION 2 #10 (CKT. #17) 1 It J PENETRATION 2 10 CK REF 2-E2.2 I REF 1-E2.2 # ( T. #25) 2 #10 (CKT. #33) - ._ i 2 #6 (CKT. 29 �13 2 #8 (CKT. #21) I 1 #6 GND# ) 2 #10 (CKT. #5) E.W. .e µae_1„ _ _ _' 33 (PART.1/2) _ °.;..___2_#6 (CKT. #29) 1 #10 GND 3 (PART.2/2) 1 #6 GNDIN 1"\ S @ IN 1-1/4"C5 9O0 �9, 2 #6 (CKT. #29) 1 6 ."ND IN� "0. 2 #10 (CKT. #33) #10 CKT #1 C T: p25) 2 #10 (CKT. #5) 2 #10 CKT #5 '1 #10 GND 2 #10 (CKT. #33 �� 2 #8 (CKT. ##1))21 IN 1 C. 2 #8 GNDT. #9) 7 2 #6 (CKT. #29)2 #10 (CKT. #5) IN 1"C. 1 #6 GND IN 1"C.1 #10 GND2 #8 (CKT.' #29) IN 1"C.—' 2 #10 (CKT. # 1 2 #8(CKT.\1 #8 GNIN 1"C. 2#10 (CKT. #13) 2 #10 ,(GKT. #17) 2 #8 (CKT. #21) 1 #10 GND 1 #10 GND 1 #8GNDIN 1"C.IN 1"C. IN 1"C�+T2 #8 (CKT. #29) 1 #8 GNDIN 1"C.�Loi I rZ 1 #8 GND IN 1"C.� 1 / I o SITE LIGHTING PLAT NTS O FIXTURES POINTED TOWARD THE BUILDING SHALL BE CfRCU1TED AS THE "PARKING SECURITY LIGHTS" CIRCUIT NOTE: SIGN INSTALLER SHALL PROVIDE THE REQUIRED STEP-DOWN TRANSFORMER AND DISCONNECT WHEN SIGN VOLTAGE IS LESS THAN 48OV. w in' oa oom §9 o z eaF: 20115 o � ����`r�wo WU om Om Z5 ��wQrc�Na> w a z Foo aw Z a so,Ww� ow W6m�z aaoza Fa zolm 7 aZFrWFWmV�=o�W a mop--�am�g-8wsw F Nuwi�Fz5a�zw�iw�o N �oai..<Wo<m Waw Oco F CO OCY. rte+ E-3 W o' �i 0_i 0 cc c� J0 ISSUE BLOCK 1,&111/17/041C.C.D. #2 CHECKED BY: DRAWN BY: O " p;wW- W FILE NAME: cnWaNd��� PROTO CYCLE: o.�W.o'Q DOCUMENT DATE: 0mOsW .�K =wza. W U n.pJ� w FoaW oW_ O Wj 0 a <0� LLIZ WZ Z 0 J d W w Q v w V) Oco F CO OCY. rte+ E-3 W o' �i 0_i 0 cc c� J0 ISSUE BLOCK 1,&111/17/041C.C.D. #2 CHECKED BY: DRAWN BY: zw w O� FILE NAME: E1.2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 O U zw w O� Q } W U�fn0 W W U n.pJ� w O 0 a <0� J d W w Q w V) N :m m p W awaw �<�00 L �zw91sZ,iLot �aaJz 1 U Q Z ZSLJ 1 zz �OO�� oz lil p m H 5 N w �� a =w5=ate a _d Lo EL Co a- fn O LIGHTING DETAILS AND SITE LIGHTING SHEET: E1 s� NO k , L jo y, MOUNT ABOVE`' j 1"C CEILING L4D2 r TYP OF 2� 19� 2 PHARMACY DRIVE-THRU POWER PLAN O WP, GFI 14 13 12 150'-9" 11 10 16.223 O O O o 2 128'-6„ E2.4 F ------------------- ------ — -- ---- "j r ^ _- -- wy ..... _.. ,A '�"' k`.... _,._ w '!" . .._.n9e, ._,.. «. I'd _ „ i 3 ` L LID 72 4 r I ( H1A n a _tom � _ . _..1 ,,w. H1A 21,20 r i IMAU1 I i L IR L_J 7 � �{ TU 3 RTU38 { x \.. ,.y TELEPHONE B , I SERVICE �.. 5 E2.4 ,. E3 I GE2 — -- I _n — - - -- — — _ 12 19 -, . H1AL1D ,i H1A k H1A r 80 H1A H1A 78 r w.._. II 15 d I I L1 D �. 1 3 it r r RTU32 RTU30 ...; ... Z t .. ,: �y #. ', �; a � 2 d r z i; ;:i ., ..... •rx .n .. .� .. ,....�.. _,n..°l k ;€ ..p ':'r ,i I ., RTU341 .' _ _.,.__E.._ •:€. r *easy N: - �.«s*'.. p 1 � :,; RTU29.:m rr..n. � : � I `� � I a 7 1 I I I i I I 1 ,.,«.R,.® ax... .gym rr`x"-. ~a- �.,.. a. i+�l r I ,r . a E "% H1Al: c r k� :. , .. 1 .: � , 2' -3� , IX .1 �at Q . c ='. H1A irAxz .,:.v: swa,..n,_.. H1A w,;, t .: s e z n '' 4 16 14 ., �s`" 18 a 4, 1 ate. RTU33 „'I 1. , • "r' e , SIN, � � . _. . — „ € RTU28IL L_JRTU31 ,_,. -° @.,',, it , �4r. ^ ,. ., ,: c u ,_._, _a......,y,.._:„,_..,•.,__t ....._..�.._....,., ,...r—t 4II,,.,:I RTU35 1 E 4 6 II T'' ;'h `7 : 3" r L1D H1A H1A 74 LID a _ rn L 761 H1A k r H1A 10 RTU25 RTU24 t n r �IL I it _•j 1 RTU26 I L J I 1 AHU2 6 2 s I rr`j I I t I — — — . RTU 23 • �° F _.J , I GROCERY SALES I' L--------)` H1A 4 �I 1 _ { III ` I H1A r 1"_. k,1 ` I H1B RTU21 H1A 7� r- ------------------ AHU3 L J TYP RTU20� ! I RTU22` SALES 6.229 I II L_J a s I t i I � e €I I ! 1 i 13 f TYP E3 � � H4B v H s I AHU1 ; d s I $ : __ _ __.u__. _. __._... m. _.-I--- LJ_ 1 17 _._. HIA 116 H1A H2A 2 H2A. GENERAL POWER NOTES I. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL FURNISHED PRE -WIRED POWER POLE AND TERMINATE PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO SECURE TELEPOWER POLE PLUMB TO BUILDING STRUCTURE. 2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION POINT. 3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE TO APPROPRIATE RATING PER NEC. 4- ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES AND CONDUITS SHOWN ON POWER PLANS SHALL BE PROVIDED UNDER THIS CONTRACT. IN ADDITION, UNLESS NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES APPLY: A. ALL ALARM JUNCTION BOXES SHALL BE 4"X4"X2-1/8" MINIMUM. B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH PULL WIRE AND INSULATING BUSHINGS. C. VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE EITHER CONCEALED INSIDE WALL OR SURFACE MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL VERTICAL oRUNS SHALL BE TURNED 90 -DEGREES AT K TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE BY VERTICAL FLOOR TYPE LIFT. 5. UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR TO ENERGIZING CIRCUIT: A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. B. PERFORM CONTINUITY TEST. C. VERIFY PROPER PHASING CONNECTION TO ALL THREE PHASE MOTOR LOADS. 0 KEYNOTES J 16.222 MOUNTINGF 0 CABLE TRAY: CABLE TRAY TO BE MOUNTED ABOVE BAR JOIST. WHERE PERPENDICULAR TO JOISTS, UTILIZE TOP OF BOTTOM CHORDS OF BAR JOISTS TO SUPPORT TRAY. WHERE PARALLEL TO JOISTS, UTILIZE UNISTRUT ASSEMBLY AS NECESSARY TO SUPPORT CABLE TRAY. COORDINATE CABLE TRAY LOCATION WITH STRUCTURAL SUPPORTS SO THAT CABLE OTRAY DOES NOT HAVE TO BE NOTCHED FOR Fi X -BRACES. 16.223 JIB CRANE: MOUNT RECEPTACLE TO GUARD-RAIL STRUCTURE. ROUTE CONDUIT FROM RECEPTACLE ALONG GUARD-RAIL STRUCTURE AND PENETRATE WALL 2'-0" BELOW ROOF DECK. 16.225 ELECTRONIC ARTICLE SURVEILLANCE SYSTEM: MOUNT JUNCTION BOX AT TRUSS, EXTEND CIRCUIT AND TERMINATE TO RECEPTACLE IN EAS ENCLOSURE UPON INSTALLATION OF EAS SYSTEM. PROVIDE 3/4" CONDUIT (WITH PULL WIRE) FROM ENCLOSURE, ROUTED UP TO TRUSS, OVER AND DOWN GATE POST OPPOSITE FROM ENCLOSURE. PROVIDE 6'--0" OF LIQUID -TIGHT FLEXIBLE METAL CONDUIT G AT EACH END OF CONDUIT. 16.229 AIR HANDLING UNIT IS PROVIDED WITH A DISCONNECT SWITCH AND GFI DUPLEX RECEPTACLE. 16.230 PROVIDE NEMA 3R 12"x12"x6" HINGED, LOCKABLE, GASKETED, JUNCTION BOX (HOFFMAN # A-1212CHNF OR EQUAL) MOUNTED 24" ABOVE SIDEWALK. PROVIDE SIMPLEX TWISTLOCK RECEPTACLE, SIMPLEX IG TWISTLOCK RECEPTACLE, AND VOICE/DATA JUNCTION BOX INSIDE ENCLOSURE, PROVIDE FEED THRU GFI DEVICE (LEVITON #6490-1) AHEAD OF EACH RECEPTACLE. _- 16.233 ROOF TOP UNIT IS PROVIDED WITH A HA CR F RATED CIRCUIT BREAKER AND GFI DUPLEX 0 RECEPTACLE. 16.234 EXTERIOR SIGN POWER: MOUNT JUNCTION BOX(ES) TO WALL IN CEILING SPACE 6" BELOW BOTTOM CHORD OF BAR JOIST, UNLESS NOTED OTHERWISE. COORDINATE LOCATION OF ACCESS DOORS AND PROVIDE FINAL POWER TERMINATIONS. 16.611 UNITS WITH SMOKE DETECTORS: PROVIDE 3/4" CONDUIT FROM LOW VOLTAGE WIRING COMPARTMENT, DOWN THROUGH ROOF CURB. 16.651 EXTEND SALES FLOOR CABLE TRAY TO LP OFFICE. PROVIDE SOLID BOTTOM TRAY FROM SALES FLOOR TO ABOVE LP OFFICE CEILING E SPACE. PROVIDE A SOLID BOTTOM 0 90 -DEGREE ELBOW AND TRANSITION S ION TO LADDER STYLE CABLE TRAY FOR VERTICAL SECTION WHICH EXTENDS 6" BELOW LP OFFICE LAY -IN CEILING. PROVIDE CABLE TRAY BRACING TO WALL 12" ABOVE LAY -IN CEILING. Ee RTU18 RTU17 L J () RTU16 I f4i: i RTU19 16.233 TYP 16.611 TYP I 3 H2A---- i I 15 z I (D 0 ...._- LGC I RTU15 J H2A I 11 10 9 8 7 6 5 H2A 2 35 I 1 I H2A H2A H2A H2A H2A H2A H2A J i RTU11 --- — --------------- —------- — ------ -,--------------- - r i H2A :.. 41 L I R TU 14 I I L J I f ,... , I I -], L_J L_J L_J RTU7L J RTU6L J r H2A RTU2L r 3 1 39 I " t 3 I L4D2 37L2D 13q II II RTU10 RTU9 RTU84-3 '.?' RTU51 4 h 12A I ! 3 ^ ---- L2D1 E2.3 4--11.7 4'-5° �4'-111 RTU1 0"WP' GFI +6H2A 24'-6" 2 4' -7 � 9 ..w k , 2 WP, GFI, +24" I II 12 I _. _L2P 2 s RTU41 % RTU31 16.651 RTU13 I , 4 w_...__., u . - t t J J J J4. J J J J ; ','. (;� a.., ,_, 1.�.Y f,x-tt dam: t�,I�-._.:I w,... ',i,. .,.."" ..:frs� LGCPART. 1/2) ----- — 0 28 REF 4-E2.3 .' I i �I L_JRTU12 I ; I I �L4D2 rt Y• ". I II L2P A 16.234 L2P 11 II i f I TY WP6 —7 .— —J P, GFI, +24" FI, +24" 8 W 16.225 l{ GE2f GFI, +24" 13 13 39 L2D1 L2D1 16.230)2 clrF cFcl { {ry1t�3a 1F; _�a O ¢ �> cn cn o 0\'W<zzww 0 'w w z wow �'L¢o�w Nw �o O p U 7zw sn ��woow w O m ¢� a> m O 3wi ora vwio�azOoz H c�a �o azo azoza � Q4J fnw�W yUU2NJ �2��—wFyLwwHn p0 t -W ¢K�U Ow O� F ww SSKtn� � �wg �pSrmO�Uao in lk-24 zcn o DRAWN BY: /�y11AaN N Ww� Ow FILE NAME: W °oow PROTO CYCLE: wf'_�ooz :n DOCUMENT DATE: �Ina- as��m,nc> �ri UIn0 lujzo� j' jm�app co Mw Ymrnz Z Q I--I��.x w xw z O J WWx JwFlai � v wzz�w < C) I 0 J �- w¢ W o lk-24 CHECKED BY! DRAWN BY: FILE NAME: E2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 UIn0 U w U Ems., W ¢ w v (nz�J Y J W Q < C) I ak J �- w¢ W o LLJ W cn �M o Oto c U J F- < ww a w m ~d~moo �woww �aaQ�z CHECKED BY! DRAWN BY: FILE NAME: E2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 O� O U Z w W 0o r < >- Lj UIn0 U w U O W ¢ w v (nz�J Y J W Q < C) I ak J �- w¢ W o i W cn �M o w N 0]a0 - U J F- < ww a w \ ~d~moo �woww �aaQ�z U Q Z =:2 LJ >_ Z:: cnoz L'Lf,� MI- En WLYKW W WOW w< F"' Q W = w D x H E U Q POWER PLAN mss. ;a�rv��-�m�vas pc I4S a $I R -4 I� Lit 3 i I Ln _., _J t .�K1 ! ��` t I 1 I K ` I g R PD1 I SPORTING GOODS 6 f� .t J AUTO APPEARANCE 23'-0" ? S " PICS1/2)38® € _ I (PAR 42 a, REF -E2.4 L2D1 L2D1 I I i s MOBILE ELECTRONICS i 00 J € € L2P I N g 302826 30 € t 12'-0" .._. 24'_5» PD3, CEILING FAN DISPLAY s ° INSTALL CEILING FAN .DISPLAY I i STRUCTURE, INCLUDING STRUCTURE 11'-0" ASSEMBLY, MOUNTING AND CONNECTION TO CEILING FANS. --- - - _ -- g VERIFY LOCATION WITH STORE PLANNING SETUP SUPERVISOR w r 01 J 7 5 L2D1 ICUTE CONDUIT FOR $ I € x J L2D1 R!CEWAY ALONG BACK 0 118 OF SHELVING UNIT TYP----- PAINT 7 BOOTH n ri COLOR CHIP 00 J a BOARD i 8 E t J I [ Li q4i^ i i S r o k { i $ N AT STRUCTURE ,�, � FOR TELXON J _ ANTENNA ! to i B I N I 34 2P LA i n of- - i tt J�,'ARIUM PD1 i 0D WALL 2SEASONAL 04 E2.1 TYP_...._..._ I to, J .LPTV € i J ro 36 4 2L2D1 Y e - 10l o c j 0 NOTES: (1) CONNECT VENDOR FURNISHED 12/3 AWG SEALTITE WHIPS TO JUNCTION BOXES. (2) GFI PROTECTION FOR CIRCUITS PROVIDED IN SYSTEM. O 4 3 1 i Li 4 ...,> _�i.. ` 7z".-. .._.av- .r'.--• �a`. f �Y r.:� u.. e�fl s F .. _ ,�# '�, �. � + L,.a,.....i c._.EL"i .....li._..{�L...:i�L -�-,. -ry-�, ''�`'''�"av�,�{;�''";;t'' ...._�... #F�w..;w.^Y ..m�.'vRISgI ! � t,�4.1 S � � •�z I � '� $ `� `" p�, -_- � 11 ,�' _ - V Viz. _ � �- .. n.. __...___ � E � g� i 4 A i 1. I t t� " 1 r' F i p� 21 '-0" T STRUCTURE FOR I j� I 6t t Ik TELXON ANTENNA i It g PICS +72' I. �t LPTV LPTV J IW B06TWALL^- L1D70 to t I + I + T - j 23 j 3 I I I L2P �- } 9'-0nt 23'-8"I € I I 11 ___ _ Ljj_ sI Nj i AT STRUCTURE J LID `AT STRUCTURE gl, FOR TELXON LPTV N I ANTENNA -� r.,, c I f I Ic I + x _ _ — ri i �G4 �F wi _ ..... .«............. _.....«... ... ....... _. .......-..__. .,. ..,... -... _.. .,..:. _.... _. ..._.e.,« ._ ......... <......._.......—......... NCL.........-, _........,._... ..„».. - W .. ,_...... .. ......... .<................_..._.._..> ...r«,.._..» ......._... ... ..u..,..... —.. _............._....._...«.«.... _..... w _"„2'., ... ... � .. .........„... _ .. ._ ... ea......,_. ,.,. ... . � ' m ....... '. 4 moi..._...,. MOUNT RECEPTACLES ON 34 t i ! 3' ,3” 95'-2" I TOP OF DISPLAY UNITS I ig — i L------- — PICS -------�----� 4 LPTV 12'-0" € v i ff Ik PICS I > » ' 18'-7" {'-9kn " € I € I 1 I I8 -7 TOYS S N PD4, P OMO TV'S Lmm j I - _{ I 1 Fr IrL 010+ I �41 I3 I I f � 4 —I2OWD E 14'-0 PRE--N-RUED- ...1,— � PD1 SINGLE CIRCUIT WIREMOLD ELECTRONI S o GROCERY SALES' y ) (3000 RACEWAY WITH (4) + TYP OF 2 3 DUPLEX RECEPTACLES ao PD1 " i. t + i ° 4 I EQUALLY SPACED. MOUNT 21 SEASONAL RACEWAY AT BACK OF L2P J } I +€ DISPLAY. VERIFY HEIGHT AND s + + k22'-6" j LOCATION WITH STORE » 8 3 I ! PLANNING SETUP SUPERVISOR 1 -10 PICS PRIOR TO INSTALLATION i I 13'-6" I s' TYP 16.401 u PICS WIRE CUTTING TABLE I'-6" L2P 359 33 3 g in 42 38 L2P i 40 PD1 J J t0, -3 } +2 0"J I I EASONAL TYPx l 31 J + E PD2 +ITTING ji € i 2 LPTV i FR OM io PD1 " I 2 2 37 ;.� 18'-6" € { COFFEE GRINDER g°_g" f J J_ 25 39 I ; N € 1 L2P eI 27 c J MISTING SY TEM xal 22'-0" n JEWELRY J -2D1 ««— ._ 00 - -- PICS 7 5 3 8'-4 11 11 14 so L4D2 PD1, CARDS - - — R UTE CONDUIT ALONG PI �L2D1 33 33 PICS PICS I L4D4 L4D4 SH MNG UNIT BETWEEN 14 s 6L4D4 -0 15'-6" RE EPTACLES TYP OF 2 36 L2D1 + 10'-3" OL4D4 I,4 o EDC4 E L2P L2D11 15'-2" 8'-0' » -0" 16 13'-O 11'-2" 10'-0" 16 8 9 -6 15'-0' 15'-0" L'I I`41D4 L4D4 24'-6" 6'-0" 14'-6" BLOOD PRESSU E J J I,8'4 f�L2D1L2D1 X58 i 22� J J r, I ACHINE2 ® ® '�—iE, 'I2 j „ rt L2D1 I 20- I € LPTV L� .. Dl LP V 9 L2 18 I PD1 <J 22 J J J L2U 24 22 22 18L2P I j II€ ,f.� 8'-0" COSMETICS L2D1 L 1 PD1 14 L2D1. € 14 CIGARETTES L .1 OT 8T 2 I4 L4D4 L4D4 L4D4 L4D4 L2U1 TYP OF 5 0 4 0ell - I L I 1 4 i ED ES 4 Ij I , .., ............:.e ",^,� ._ a„m,....,r. -• .d..,i..-`.: ._."Zm "'o'°..-^' ^.-e`.�.w'u.-". _-•.-�..-. , _.:... N .. ...«�.... _.. ......m. 4 «'»... -u.,. ..._-..... _... -4.r .»..•�" t3....�.._ ...._...... «,....,...-. _.. tom...«.. e. --..«-• _...a.... _...._.. _,.. ._—.. _• - yam; 3 � --4—.. y I I PICS J J S) Sn c.+20" 9 I p L4D22 _F# -L2U L4D4 LPTV .. - r,L4D4 I LPN AT STRUCTURE FOR s (� 16,401 T ON ANTENNA I TYP 8..6 III �t B s L 3 ��l 1 -+..n asap ��. �� _ .,1................�,.. _ ....�...� » _.�...... ,.. _.--^-_ ... �3,........,.....ry.. D 4 ='S x saa Bo�oa��wo p�kzduax'a>zm Z 7 Ww z— aro=Q�g� w0 O 3swFa$j�,3E60 IdE LEFT SIDE OF AQUARIUM WALL PROVIDE SEPARATE NEUTRAL FOR EACH REFER TO DRAWINGS FOR PREP STATION E2.1 PROTO CYCLE: CIRCUIT CIRCUIT IDENTIFICATION 08/11/04 � 6'-0' •a i two w V L1 PI J P2 J 1�1 >-aa�o w �-> w fE a 1'-0" 1'-0" 0¢zz�ui a- O =c'2 15 w mr-5;wwwi2 z�F L1 - LIGHTING w 6 a _woct.wit w p - - P1 - HEATER P2 - PUMP/CHILLER j O 4 3 1 i Li 4 ...,> _�i.. ` 7z".-. .._.av- .r'.--• �a`. f �Y r.:� u.. e�fl s F .. _ ,�# '�, �. � + L,.a,.....i c._.EL"i .....li._..{�L...:i�L -�-,. -ry-�, ''�`'''�"av�,�{;�''";;t'' ...._�... #F�w..;w.^Y ..m�.'vRISgI ! � t,�4.1 S � � •�z I � '� $ `� `" p�, -_- � 11 ,�' _ - V Viz. _ � �- .. n.. __...___ � E � g� i 4 A i 1. I t t� " 1 r' F i p� 21 '-0" T STRUCTURE FOR I j� I 6t t Ik TELXON ANTENNA i It g PICS +72' I. �t LPTV LPTV J IW B06TWALL^- L1D70 to t I + I + T - j 23 j 3 I I I L2P �- } 9'-0nt 23'-8"I € I I 11 ___ _ Ljj_ sI Nj i AT STRUCTURE J LID `AT STRUCTURE gl, FOR TELXON LPTV N I ANTENNA -� r.,, c I f I Ic I + x _ _ — ri i �G4 �F wi _ ..... .«............. _.....«... ... ....... _. .......-..__. .,. ..,... -... _.. .,..:. _.... _. ..._.e.,« ._ ......... <......._.......—......... NCL.........-, _........,._... ..„».. - W .. ,_...... .. ......... .<................_..._.._..> ...r«,.._..» ......._... ... ..u..,..... —.. _............._....._...«.«.... _..... w _"„2'., ... ... � .. .........„... _ .. ._ ... ea......,_. ,.,. ... . � ' m ....... '. 4 moi..._...,. MOUNT RECEPTACLES ON 34 t i ! 3' ,3” 95'-2" I TOP OF DISPLAY UNITS I ig — i L------- — PICS -------�----� 4 LPTV 12'-0" € v i ff Ik PICS I > » ' 18'-7" {'-9kn " € I € I 1 I I8 -7 TOYS S N PD4, P OMO TV'S Lmm j I - _{ I 1 Fr IrL 010+ I �41 I3 I I f � 4 —I2OWD E 14'-0 PRE--N-RUED- ...1,— � PD1 SINGLE CIRCUIT WIREMOLD ELECTRONI S o GROCERY SALES' y ) (3000 RACEWAY WITH (4) + TYP OF 2 3 DUPLEX RECEPTACLES ao PD1 " i. t + i ° 4 I EQUALLY SPACED. MOUNT 21 SEASONAL RACEWAY AT BACK OF L2P J } I +€ DISPLAY. VERIFY HEIGHT AND s + + k22'-6" j LOCATION WITH STORE » 8 3 I ! PLANNING SETUP SUPERVISOR 1 -10 PICS PRIOR TO INSTALLATION i I 13'-6" I s' TYP 16.401 u PICS WIRE CUTTING TABLE I'-6" L2P 359 33 3 g in 42 38 L2P i 40 PD1 J J t0, -3 } +2 0"J I I EASONAL TYPx l 31 J + E PD2 +ITTING ji € i 2 LPTV i FR OM io PD1 " I 2 2 37 ;.� 18'-6" € { COFFEE GRINDER g°_g" f J J_ 25 39 I ; N € 1 L2P eI 27 c J MISTING SY TEM xal 22'-0" n JEWELRY J -2D1 ««— ._ 00 - -- PICS 7 5 3 8'-4 11 11 14 so L4D2 PD1, CARDS - - — R UTE CONDUIT ALONG PI �L2D1 33 33 PICS PICS I L4D4 L4D4 SH MNG UNIT BETWEEN 14 s 6L4D4 -0 15'-6" RE EPTACLES TYP OF 2 36 L2D1 + 10'-3" OL4D4 I,4 o EDC4 E L2P L2D11 15'-2" 8'-0' » -0" 16 13'-O 11'-2" 10'-0" 16 8 9 -6 15'-0' 15'-0" L'I I`41D4 L4D4 24'-6" 6'-0" 14'-6" BLOOD PRESSU E J J I,8'4 f�L2D1L2D1 X58 i 22� J J r, I ACHINE2 ® ® '�—iE, 'I2 j „ rt L2D1 I 20- I € LPTV L� .. Dl LP V 9 L2 18 I PD1 <J 22 J J J L2U 24 22 22 18L2P I j II€ ,f.� 8'-0" COSMETICS L2D1 L 1 PD1 14 L2D1. € 14 CIGARETTES L .1 OT 8T 2 I4 L4D4 L4D4 L4D4 L4D4 L2U1 TYP OF 5 0 4 0ell - I L I 1 4 i ED ES 4 Ij I , .., ............:.e ",^,� ._ a„m,....,r. -• .d..,i..-`.: ._."Zm "'o'°..-^' ^.-e`.�.w'u.-". _-•.-�..-. , _.:... N .. ...«�.... _.. ......m. 4 «'»... -u.,. ..._-..... _... -4.r .»..•�" t3....�.._ ...._...... «,....,...-. _.. tom...«.. e. --..«-• _...a.... _...._.. _,.. ._—.. _• - yam; 3 � --4—.. y I I PICS J J S) Sn c.+20" 9 I p L4D22 _F# -L2U L4D4 LPTV .. - r,L4D4 I LPN AT STRUCTURE FOR s (� 16,401 T ON ANTENNA I TYP 8..6 III �t B s L 3 ��l 1 -+..n asap ��. �� _ .,1................�,.. _ ....�...� » _.�...... ,.. _.--^-_ ... �3,........,.....ry.. D 4 ='S x saa Bo�oa��wo p�kzduax'a>zm Z 7 Ww z— aro=Q�g� w0 O 3swFa$j�,3E60 IdE ISSUE BLOCK rd I 11 CHECKED BY: DRAWN BY: FILE NAME: E2.1 PROTO CYCLE: 062504 C� 08/11/04 � •a a.uj< two w V � ¢w¢w 1�1 >-aa�o w �-> w fE a 0¢zz�ui a- O =c'2 15 w mr-5;wwwi2 z�F (n w 6 a _woct.wit w p ISSUE BLOCK rd I 11 CHECKED BY: DRAWN BY: FILE NAME: E2.1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 wF O U zw w FO jE U } O N L) d ao�J V, Z a �Jw 0 a.uj< inxxo c m ¢ O w V � ¢w¢w J >-aa�o >-wocn fE a 0¢zz�ui 1 }��ou-a w mr-5;wwwi2 z�F =w�Xgzw 6 a _woct.wit w p POWER ®ROP PLAN SHEET: E2.1 S £ 77\;1 L2D2 L2D2 L2D2 L2D2 LZD21-1 2 C 33 35 29 25 31 L2D2� T `1A r— , LTS2 m] TYP 1 „ I � " 6'-4" 6'-4" Its 1 �_ 0L1k °'! I P A 136 q 16.990 TYP Ile ff I L_J oil WH 72 RECIRCULATjNCI // // i�� �' 5 s '-0" € 0 1il ;1i- PUMP, +6 ! / // ��� �� T -STAT L2D2 2123 i I A o 13 L2D2, a ! L 16.603 GM VESTIBULE I s 1 o J +84' N iI F �2 2 ( PROVIDE JUNCTION BOX AND CIRCUITRY ( FOR THERMOSTAT FOR CONTROL OF AIR 9 `�! GFI CURTAINS. REF MECHANICAL PLANS FOR d L2 — t EXACT THERMOSTAT LOCATION _ 3 4 +921 REF ARCHITECTURAL ROOF PLAN I �. DRAWING AND ROOF CAMERA MOUNTING LP ` DETAIL FOR ROOF CAMERA LOCATION OFFICE e RACEWAY SUPPORT REQUIREMENTS 1 c,+20r E 3- V CONbUI (WITH I PU _ X-Ifow GRADS EO PROVID�-SECURt ' _a 1 POLE T Y CAMt�`RAS. STUB CONDUIT +6' IN j d L.P. ROOM, WITH BUSHING. CONDUIT SHALL EXTEND TO PULL I I BOX, COORDINATE WITH CIVIL DRAWINGS 9.7 1 D f1CC1r`C OnIAICD DI AKI 4 SITE LIGHTING I REF 1-E1.2 i F 41 L2D1"�� DOOR SWITCH, +`P .. _ — _ — -- FOR .AI.R-CURIAII ----------- L4D4_--_w_______._____._.._ L4D4 L4D4 1_4D4 TS1 _t1 11 5, ( t +48„ I t a I I a,+42" COURTESY .F E WOMEN MEN tiI I fV MA I A I 16.221 16.221 t i DESK 1 4 L6 -30R, # 9'-6" 10'-2„ t T i 1'-0"s +48Y L2D2 202 1 till I I I _ jj a t A 16.606 p 38r 40 LTS2 LTS1 A ✓ 2 J 2 13 �i FUTURE 5# € A i L2D1 �M I 11 fI ""s ( BANK p 2 1 16.410 TYP 8 2D2 `t s LTS2 J J LTS1 tI - a L2� 42 1 i � { I TENANT 1� _ 3 R. t : i LTS2 u j 3 _ ( lisyp2JOTSBTYP LTS1 4 I tl PANEL TS3j t +54 6" SPACING 32 �� ' t IY TYP OF 3 1 � A � � _..,_. �. .659 A E`\ � � �� A _._... �...u�m � � IT L2-28 CASH COUNTING F 16 602 z. I _ r : J I a LTS2 LTS1 I t IXIV a 6 4 i 4 6 16.604 ' _y_ t L 1 L2D1 34 I L2D230 0 +90" IM L2U _2_ u \ / } a� 2D2 { I 4 6 5S2 LTS1 6 B 4 I b _ b 2 13 IW ( i` 1 � FH I 5 L2D1 Irq 3 ....._...�. 3._,_._... .. .... _ _ _....._ .....A _._...._ EQUIPMENT RETURN I I PANEL LTS2 If +90 LPN ( +12" -I- STORAGE 36"x36' ,,QEDICATB@.. 16.610 +13'-0" PA LTS1 SITE LIGHTING 1 i REF 1-E1.2 �SP CE FOR UPS DRY PIPE SYSTEM, E2.3 PROVIDE 4 a 2fFIBER OPTIC COMPRESSOR +13 -0" O 3/4" EMPTY ROUTE (2) 3" CONDUITS FOR COMMUNICATION CABLE FROM REF CIVIL PLANS t CONDUITS FROM TENANT PANEL i 3 BOARD TO CABLE TRAY AND TIRMINATE WITH BUSHING TO ABOVE BAR JOIST AND d 3 TERMINATE WITH 90' ELBOW INTO r I } TENANT SPACE TYP OF 2 9 € t € t E BAGGER, +60" CE MERCHANDISER, +60" IC MAKE CIRCUITRY FOR THERMOSTAT FOR CONTROL OF AIR CURTAINS. REF L14 -20R, +60" � MECHANICAL PLANS FOR EXACT f I THERMOSTAT LOCATION f ¢ E e I jj ..,-.d-�,.•-,.�-.,.ter-w,^,1.°�-�,»•��-v-.><` I TYP �---,rte- w^•�'��v��,..--,rte,.-a�•�"M`� I (; X16.990 6 -0 6'-0' 1 - " H4B � 32 ' S _ - - - REF SUBWAY DRAWINGS FOR < _ mgr __ ,4.._ .v.-�____ _IT_�._ _..xr. WORK IN THIS AREA °; F _ - L4D4 � � � � I L4D4- 10 ` _ 3 L4D4 A 2. 1 15 4 4 T -STAT +60" 1 7 I 16.603 ' GR 16.996 +84" I VESTIBULE +90 I L115 2 `40 T -STAT L -4D4171. sII `t TYP I L4D4, PROVIDE JUNCTION BOX AND -.2 3 +60" ( CONDUIT FOR THERMOSTAT AND J SITE OVERRIDE TIMER SWITCHOR i GR I LIGHTING CONTROL OF UNIT HEAT R. ; ENTRY I REF 1-E1.2 THERMOSTAT AND OVERR DE 1 TIMER SWITCH WIRED I 48 PARALLEL ON 24 VOLT UITi_ L4D4 3546 39L4D4 I HEATER CONTROL CIRCUIT. t REF - MECHANICAL PLANS FOR E ACT i 37 16.996 30 THERMOSTAT LOCAT1 ! i ° 39 321 b,+42" I - - TYP 'OF� 0 t ° j it. 2°" 1 -11GOR_SWI.TCI 1.. EOR_AIR_� CONTROL, TYP. INSTALL PER _d- MANUFACTURERS RECOMMENDATIONS TYP OF 2 7 o � I FOR C TO 8 TRAY -PROVIDE ON/OFF SAFETY SWITCH FOR UNIT HEATER, TYP OF 3 L4D4 KEYNOTES 16.2201NSTALL PREFABRICATED ELECTRICAL DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR INFORMATION PURPOSES ONLY. THE ENTIRE ASSEMBLY WILL ARRIVE COMPLETELY PRE -WIRED AND IS AN ETL LISTED ASSEMBLY. 16.221 SURFACE MOUNT JUNCTION BOX WITH BLANK COVER PLATE 6" ABOVE CEILING FOR SIGNAGE. 16.226 ELECTRONIC ARTICLE SURVEILLANCE SYSTEM: PROVIDE 3/4" CONDUITS (WITH PULL WIRE) FROM EAS POWER MODULE TO EAS PEDESTAL LOCATION AS SHOWN ON PLANS. STUB CONDUITS 3" ABOVE FINISHED FLOOR AT EAS PEDESTAL LOCATION AND PROVIDE BUSHINGS AT EACH END. 16.227 ELECTRIC WATER COOLER RECEPTACLE: CONCEAL WITHIN CABINET PER MANUFACTURERS REQUIREMENTS. 16.232 AUTOMATIC DOOR OPERATOR: VERIFY LOCATION WITH MANUFACTURER'S RECOMMENDATIONS PRIOR TO INSTALLATION. ALL CONDUIT AND WIRING SHALL BE CONCEALED AT MAIN ENTRANCE DOORS. 16.410 COUNTER MOUNTED DEVICES: STUB OUT OF WALL AT +8". ROUTE FLEXIBLE METAL CONDUITS ALONG BACK WALL OF CABINET. MOUNT DEVICES WITHIN CABINET AT +8". VERIFY LOCATIONS WITH STORE PLANNING SETUP SUPERVISOR. 16.412 AUTOMATIC LAVATORY, URINAL AND WATER CLOSET CONTROLS: PROVIDE JUNCTION BOXES, CONDUITS, RECEPTACLES AND LOW VOLTAGE WIRING (SHOWN DASHED) AS REQUIRED. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH MANUFACTURER'S 16.510 NOT USED 16.602 PROVIDE RECESSED ALARM JUNCTION BOX AT +80" WITH A CONDUIT TO ALARM JUNCTION BOX IN ADJACENT PUBLIC RESTROOM. 16.603 PROVIDE RECESSED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +80". (UNLESS NOTED OTHERWISE). 16.604 PROVIDE RECESSED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) CENTERED 2" ABOVE DOOR FRAME. 16.606 PROVIDE THREE RECESSED ALARM JUNCTION BOXES (WITH ONE VERTICAL RACEWAY), INSTALL BOXES +52" TO BOTTOM OF BOX AT 10" OC WITH 3/4" CONDUIT NIPPLES ETW .EN)�§c 16.607 NOT USED JUNCTION BOX (WITH VERTICAL RACEWAY) AT +84" (UNLESS NOTED OTHERWISE). 59 N U f L EVE: PR VIDE 2 0 (WITH PULL WIRE) FROM 8" BELOW CEILING TO 12" ABOVE CEILING AND TERMINATE WITH BUSHINGS. 16.661 DATA AND PHONE CONDUIT: PROVIDE CONDUIT SLEEVE THROUGH WALL AND ROUTE ABOVE BAR JOIST, UNLESS NOTED OTHERWISE. ROUTE CONDUIT TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" OVER CABLE TRAY. 16.990 AIR CURTAINS: MANUFACTURED WIRING BETWEEN UNITS FURNISHED WITH AIR CURTAINS. INSTALL PER DRAWINGS AND A lU ACTRER'S RECOMMENDATIONS. � µ. 1.991 AIR CURTAINS: AIR CURTAINS ARE FURNISHED WITH DOOR SWITCHES AND THERMOSTAT. FURNISH AND INSTALL ALL NECESSARY DEVICES, CONDUIT AND WIRE FOR PROPER OPERATION. INTERLOCK FANS WITH DOOR SWITCH SO AIR CURTAINS OPERATE WHEN DOOR IS OPEN. INSTALL PER DRAWINGS AND MANUFACTURER'S RECOMMENDATIONS. 16.996 PROVIDE 4" SQUARE FS BOX CENTERED AT DOOR HEADER FOR CAMERA CABLING. PROVIDE 1" CONDUIT (WITH PULL WIRE) FROM FS BOX TO STRUCTURE. ROUTE CONDUIT ON TRANSLUCENT PANEL FRAMING AND TERMINATE AT BAR JOIST WITH BUSHING. COORDINATE INSTALLATION WITH MANUFACTURER'S REQUIREMENTS. �T-STAT J +60" AIR CURTAIN FAN MOTOR DISCONNECT SWITCH, +60" %Vlf31 CART STORAGE W6, TT o0, NQ zFN Z. �' das ZlJ 4-,NQ�JW�'pm aG W 0aOFb 3?,Z4 a> Z3uzWi?i'wooaWo"�o &o � O wwF6�VW OWN a ZO< Q ZN WEI—W Z, �F4 3 j'n� mm �Fww��o-J ootY Lit kmop F7_ in U) ic�iaa5g'ablrc��'a� ZcnQ-. I DRAWN BY. 08= FILE NAME: IxW�;ogW PROTO CYCLE: 16.99 FSwzo: z%a"'"cc i TYP OF 2 WXx 1948 I Zww�" W z ZN_1 xW�� AIR CURT6S, REF MECH FLANS aw¢W I w N g " <o �m¢D I' w v - F ph -w Q W Q LTJ J E (�EE-- Q — S A W6, TT o0, NQ zFN Z. �' das ZlJ 4-,NQ�JW�'pm aG W 0aOFb 3?,Z4 a> Z3uzWi?i'wooaWo"�o &o � O wwF6�VW OWN a ZO< Q ZN WEI—W Z, �F4 3 j'n� mm �Fww��o-J ootY Lit kmop F7_ in U) ic�iaa5g'ablrc��'a� ISSUE BLOCK 11/17/04 C.C.D. #2 2 t O1 /05/05 C.C.D. #{6 01/24/05 C.C.D. #8 CHECKED BY: ZcnQ-. I DRAWN BY. 08= FILE NAME: IxW�;ogW PROTO CYCLE: 062504 FSwzo: z%a"'"cc i HZ�OW WXx Zww�" W z ZN_1 xW�� ¢oom ISSUE BLOCK 11/17/04 C.C.D. #2 2 t O1 /05/05 C.C.D. #{6 01/24/05 C.C.D. #8 CHECKED BY: DRAWN BY. FILE NAME: E2.2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 da-'� �M>w c0 0 ¢oom aw¢W w N g " <o �m¢D w v - F ph -w Q W Q LTJ J E (�EE-- 0o �L''oww t=a. Q Jz v1 of v¢ozgw w\ 3) < �N �CL W ISSUE BLOCK 11/17/04 C.C.D. #2 2 t O1 /05/05 C.C.D. #{6 01/24/05 C.C.D. #8 CHECKED BY: DRAWN BY. FILE NAME: E2.2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 K F O U zw w 00 � a}ww w o_3 d - da-'� �M>w ¢oom aw¢W w N g " <o �m¢D w v - F ph -w Q W Q J W ~aa.��o �L''oww t=a. Q Jz of v¢ozgw w\ 3) < �N �CL wawwz 0 ir=Ljosmwa- 0 o u ENLARGED POWER PLAUS SHEET: E2,2 1" CONDUIT CONCEALED IN WALL STUB UP 12" ABOVE GENERAL POWER LAY -IN CEILING AND KEYNOTES 1" CONDUIT CONCEALED IN WALL TERMINATE WITH BUSHING GENERAL POWER JUNCTION BOX FOR LASER PRINTER VIDEO GENERAL POWER 16.226 ELECTRONIC ARTICLE SURVEILLANCE SYSTEM: GENERAL POWER ! GENERAL POWER VOICE/DATA PROVIDE 3/4" CONDUITS (WITH PULL WIRE) GENERAL POWER LASER PRINTER FROM EAS POWER MODULE TO EAS 3 VOICE DATA VOICE/DATA PEDESTAL LOCATION AS SHOWN ON PLANS. CASH REGISTER REFRIGERATOR STUB CONDUITS 3" ABOVE FINISHED FLOOR VOICE/DATA AT EAS PEDESTAL LOCATION AND PROVIDE GENERAL POWER w GENERAL POWER GEN VOICE/DATA GENERAL POWER ref q/V BUSHINGS AT EACH END. MOUNT ON SIDE -- ;' VOICE/DATA ,.y; A/V SYSTEM VOICE/DATA 16.228 INSTALL RECEPTACLE IN UPPER RIGHT HAND OF COLUMN w t, @" i fit. LASER PRINTER GENERAL POWER CORNER OF PROVIDED DATA ENCLOSURE. .m T VOICE/DATA 16.232 AUTOMATIC DOOR OPERATOR: VERIFY Wp ROUTE AS HIGH AS �_a::w _.._. ,.� ,. W. __. - ✓ s€? ` CPUp p ® p O POSSIBLE ON GARDEN RI I �}', e� p 0 ®CPU CPU CPU CPU CPU CPU LOCATION WITH MANUFACTURER'S CENTER FENCE STRUCTURE wLv - - - # = CPU RECOMMENDATIONS PRIOR TO INSTALLATION. LGC ,___.. °? 0a 00 ALL CONDUIT AND WIRING SHALL BE r ,w __._. __._.., 7 __.�.__.,..,,,_......_ . ? E , N WP, 36 _ ..__ ._.,.. _._._, N CONCEALED AT MAIN ENTRANCE DOORS. PROVIDE ON/OFF SAFETY 16.401 LPTV AND PICS MONITORS: MOUNT GFI {9 SWITCH FOR UNIT HEATER. TYP OF 2��' 9 JUNCTION BOX AT STRUCTURE. AFTER MOUNT TO BOTTOM _. FURNISH AND INSTALL JUNCTION BOX AND e__ I# j 1'-6'1'-6' 2'-5" 1'-6" 1'-4' 4'-8" 1'-8"1'-10°1'-10" INSTALLATION OF MONITOR MOUNTING w oa oo� CONDUIT FOR THERMOSTAT AND OVERRIDE TIMER s ' ` -- 10'1'-6" 2'-8" 2'-0" 1'-6" 2'-0" OF STRUCTURE �J 7" V-3" 1'_011BRACKET, EXTEND CONDUCTORS IN 1/2" o w vwa=zwg �N t a, SWITCH FOR CONTROL OF UNIT HEATERS. I. REFRIGERATOR zr= �o�� z - FLEXIBLE METAL CONDUIT TO RECEPTACLE w o a� X< z i,..o THERMOSTAT AND OVERRIDE TIMER SWITCH WIRED UH '; j � w 000�mwuiaoo IN PARALLEL ON 24 VOLT UNIT HEATER CONTROL ATTACHED ON MONITOR MOUNT. COORDINATE da�wm "<�Jw�om 'f It ! , Z' I -- !""'€ (vi HARMACY ELEVATION RECEPTACLE PLACEMENT WITH MONITOR o �w-z m,�wa��iar CIRCUIT. REF MECH. PLANS FOR EXACT __ P H /\ R INSTALLER. PAINT CONDUIT COMPONENTS TO w aozo��w ��wz �� THERMOSTAT LOCATION. , 4_10j�� iit I}MATCH MONITOR SUPPORT. z 3Uz o"�w w&oo�o wxw,,mw,o z,oZ 1/4" = 1'-0" 16.410 COUNTER MOUNTED DEVICES: STUB OUT OF zo mom www oQ #:,».,�_.-,+...,. Q Ov+z zw_�F oc. EF � "�; ! WALL AT +8" ROUTE FLEXIBLE METAL � aa� rL����o'�_ KZ�F W WWW O K CONDUITS ALONG BACK WALL OF CABINET. oo twx� oK'owo mw� onwFn omos ,� Ij I #1_._- MOUNT DEVICES WITHIN CABINET AT +8". -v��z <ozw�ww=o S,.,._..._._. 11( 9 I; It C E VERIFY LOCATIONS WITH STORE PLANNING ' } SETUP SUPERVISOR h it �I LGC ? ? } t _,_ _..,._,_ _ .. _, _., __.__ _ _z _, 16.412 AUTOMATIC LAVATORY, URINAL AND WATER 16.410 r __ CLOSE CONTROLS: PROVIDE 2 w w 5 5 3 BOXES, CONDUITS, RECEPTACLES ANDLOW�Q� VIA C1 i I: { TYP LRXf LRX I __. _.,_. _ _ Z ,. s w m w �C1C 9 f �� 4-A VOLTAGE WIRING (SHOWN DASHED) AS ��oow ({ I a t` r REQUIRED. COORDINATE EXACT LOCATIONS �W Nl2 a a a a a a a Q ,z ( AND REQUIREMENTS WITH MANUFACTURER'S aWOO�oo= �e TYP 16.41'4 = t°M^=o RECOMMENDATIONS PRIOR TO INSTALLATION. N,Mgm _._-_._ E-1ozo' ,° _ 16.41 RETRACTABLE WALL MOTOR PROVIDED BY mm41S )i L1 C +54" 4 6J9 7 4 VENDOR. INSTALL VENDOR z=-1 x z • CSO x <,, I - LRX L2U J LRX LRX L2U FURNISHED PUSH BUTTON STATION. PROVIDE ZZU,nww43i LOW VOLTAGE WIRING (SHOWN DASHED) cn W z�J FLUSH MOUNT 4"x4" JUNCTION CHECKOUT BETWEEN PUSH BUTTON STATION AND zo =W"� BOX WITH 1" CONDUIT STUBBED PHARMACY EF MOTOR PER MANUFACTURERS WIRING 7-E2.3 r„ L2 TYP DIAGRAM. aef.__- . _._. . ___ _ J _m • 1 ...._ OUT ABOVE CEILING, TERMINATE 6-E2.3 CONDUIT WITH BUSHING LRX 1 16.451 PROVIDE EMT WITH PROPERLY INSTALLED It LRX COMPRESSION OR SET -SCREW TYPE �I � WIRE PER 14 +43" FITTINGS AND AN INSULATED EQUIPMENT 7-E3 LGCI a �. _-. _.� J GROUNDING CONDUCTOR FOR ALL RACEWAYS 2i i° I ; ; a SERVING THIS ROOM TO COMPLY WITH NEC, ',� `; a, j,. a, a, +43" GFI 16.653 ( „ f 6 16.228 TYP' HEALTH CARE FACILITIES. *` j ; " ° LRX 2 16.412 16.453 PROVIDE A RECESSED SINGLE -GANG BOX i; it !�! �a w 4..} A WITH WIREMOLD V2448 SINGLE -GANG DEVICE Q �y it ;I it _ t f ! S si • PANEL TOILET ^~ I BOX TO SERVE PLUGMOLD STRIP. PROVIDE OR, EF 11 �\ 16.603 THE RECEPTACLE AND COVER PLATE IN THE ^1 1 it [4 "I }i I i (E 6F r S" ; 1 X SURFACE DEVICE BOX o __ .. LR It P ! LRX J N E 3 sat T �I I WH 13 19 16.454WTH IWIREMOLDEV244D8 SINGLE-GANG GANG DEVICE p� s, �.:-_: _:, ��.; r LR LRX BOX AND BLANK COVER PLATE TO SERVE �I X 15 17 21 23 o a: 5 PLUGMOLD STRIP. LGC LGC _.__. �" Iw _ yt'i, l VIA C1 8 } I 16.45 INSTAL FURNISHED WIREMOLD V24GB Qy ! I WP, GFI, +60 LRX f1, 2` �_ ��}' °' S SERIESPLUGMOLDFEDRFROMDSURFACE W I WP, GFI, +60 a LRX 10 g t g s �` ' l l r _• 1� _ _.,_',.m _ DEVICE BOX. o PANEL LGC s 17 15 21 16.460 PROVIDE JUNCTION BOX ABOVE CEILING, � 4 rr 6a f CF FAN SPEED CONTROLLER 17 23 1/2" CONDUIT DOWN INSIDE WALL AND _ REF MECHANICAL DRAWINGS #; €? LGC �� TRANSITION TO 1/2" FLEXIBLE METAL O ?I 10 LGC ZMOUNT ABOVE CEILING, CONDUIT EXTENDING 24" OUT FROM WALL a UH 29 LGC PART. COORDINATE LOCATION WITH FOR CONNECTION TO QUADRUPLEX w LGC 24LGC 372 2 STYLINGABAR.AVDRBOXACTUAL LOCATION /) o LGC PHARMACY P 0 WE R PLAN BLOWER MOTOR INSTALLER <r 31 1/4" = 1'-O" WITH TENANT. Z 34 / LGC • CONDUIT TO 16.603 PROVIDE RECESSED ALARM JUNCTION BOX p 22 OUTSIDE 6.232 ABOVE CEILING (WITH VERTICAL RACEWAY) AT +80". 8 TYP— (UNLESS NOTED OTHERWISE). BAG GOODS 16232 • '� i DUPLEX 16.650 CONDUIT SLEEVE: PROVIDE 1-1 2" CONDUIT RH VOICE DATA SLEEVE WITH BUSHINGS ABOVE BAR JOIST ISSUE BLOCK M1. LGC RECEPTACLE -VOICE/ DATA 1' CONDUIT (WITH PROVIDE 1" CONDUIT (WITH 16.661 i JUNCTION (UNLESS NOTED OTHERWISE). 11/17/04 C.C.D. #2 ±' 25 PULL WIRE) FROM DOOR 1-1 2 C N BOX PULL WIRE) FROM DOOR_._ _. _ _,_._,.___..__,__ ._ ""' `. 16.653 CONDUIT SLEEVE: PROVIDE 2" CONDUIT _ HEADER UP TO STRUCTURE. I N HEADER UP TO STRUCTit URE. w _. __, .. .__ __,. ___ _._ ,__,,,, __.. ,_ _ �..,. __. _ _ .._ E... w (WITH PULL WIRE) FROM 8" BELOW CEILING LGC TERMINATE WITH BUSHING TERMINATE WITH BUSHING ""' - i ; RACK POST ti. VIA C2 --- �` IL'li TO 12" ABOVE CEILING, TURN 90 DEGREES _ _ _ t _._.._.. _..a_ { i TYP 01 AND EXTEND TO NEAREST ACCESSIBLE C. 5 9 w �� ` �' ' CEILING SPACE. TERMINATE WITH BUSHINGS. EF s I� SHELF [ I ". I TYP Lg 16.661PROVIDE NE DATAAND � SLEEVE THROUGH WALL AND ROUTE ABOVE BAR JOIST, UNLESS NOTED f 0 f I ;r}3C ODE OF I CABLE TRAYSE ROUTE WITHITHE OCONDUIT THE OP I �Clgg �. i ;,i __; Ui EXTENDING NO IC RH OPTICAL i e �: MORE H --- CONNECTOR AND BUSHING E IN OR THAN 1" OVER CABLE TRAY. SALES 1 9 N U E P H A R M A C Y RAC K P 0 WE R " NTS � a � LGC t _ ; 16 "' [ I , JB AT STRUCTURE � I ~ FOR POWER POLE �I �I si ii L3 INSIDE I I 6 TYP OF 6 I Is r1 • SALES r I p O I CHECKED BY: Ii is :1 CF +16„ I#, DRAWN BY: g FILE NAME: E2.3 L4 • I +16" g II 1-1 2'C RADIANT; HEATING SYSTEM NOTE: it ° r LVC t 16. 61 t tj �} �' PROVIDE CONDUIT AND JUNCTION BOXES 4 ! PROTO CYCLE: 062504 I "t LVC,- _ _ _._ _ _. _ _..._ p } I; AS REQUIRED BETWEEN BURNER BOXES ? ? ! AND THERMOSTAT, AND MAINTAIN MINIMUM I'_._ ___ __ 3 _ _ _ __.__, ,__.____ Y_ __, ____,__m ____�__ - € u l t - S DOCUMENT DATE: 08/11/04 CLEARANCES PER MANUFACTURER'S _-----'p---�---- LGC ; p 'P _' i RECOMMENDATIONS, REF MECHANICAL PLANS p<p °� ) .,.._ .....: . 4t VIA C2 I ...3 lil t £= a ,.... ..__9 S I ; st' FOR EXACT THERMOSTAT LOCATION. w 13 I - it it it ti ,-WIRE PER I e 7-E3 I 1 f it � EF i I .__._ �I� s i if I i; It ��;; _., 16 _ ,� .._J 9 r C L �" L HC � r , 1 HC ¢4 `' � • �-- I a FLUSH MOUNT , SALON IN CEILING L8 € � 13 LVC �il 8 , (�7- � i_ -- LVC 16.454 EF I 1 i ( FOR TV ' 1 +44"14 I RH ftit tl n- ,.................: .:... ......... ___..,_ _._......,..__._,_. _ ;f t ��. __, € i i6C t _ LGC a J " 20 '4+46" +50„ 16,455 +44„ +12' L J TYP I 41 I CF'FAN SPEED ��` r _ 11 �f ;° 13 , L 18 CONTROLLER Of LGC __ ______,__ a of ¢ LVC 12" I,i E of 5 0� REF MECHANICAL 27 • - x I it, yu DRAWINGS GFI +12" O a. 7 9 PRETEST I i` J o RH LAB LVC B J i 13 11 g � wo • LGC I LHC TYP 16.460 TO L6 _:. 37 i +44" 16.453 t +12"ot 5 5 d w u a w o n. - WP, GFI +60" ON COLUMN. ROUTE (PART. 1/2) 3 cnz J Y CONDUITS ON SIDE OF COLUMN- 16.401 RH • L8 �J - - _ :, ? 42 LHC LHC zoa� x 4 1 3 _. M COLUMN- LGC J a VERIFY LOCATION WITH STORE _ t u a TO L5 1, 10 Q _ of uj b" VCA C2 L « PLANNING SETUP SUPERVISOR PRIOR p, LHC j w w n TO INSTALLATION. TYP OF 10 6 LPTV LGC 17 b VENTILATION EXHAUST FAN SWITCHES I ;I q Z w L C L C PANEL LVC v" �' J w m o z 23 LGC 7 PROVIDE SIGN THAT READS z s O _.. 4 - LGC 26 E3 " LVC 2 }t EF Q w a VENTILATION FA SWITCHES CF 21 OPERATE ONLY WI SiDEWALLS LVC € jj DRYER NEMA 9 J _ I z = = z a J J J J J J OPE I I 3, _ w AREA ! 14-3OR d 0 o WAITING O 0 O O EF + J J -- a��zww LFt J J J J 2 J J I 4 I_ a z�aaaz.. 48" LGC 7 CONTACTOR ( E O z C1 AND C2 _.. o > v v o a AT STRUCTURE „_� �__ ,..__. _ .. q.`- _. .7 9 - a_...I a w m S o ' TYP OF 8 _ O w z z 1 WASHER 20 LHC '' ! i v! x a o- 0 a a GFI _WHLu q i --, �,: RH PROVIDE BLANK JUNCTION BOXES a I CONTACT { i LVC f �i / t i J +48" I t.,_ d_ o a v o n o _.__..._ ___._ .._ ._ RH 3 i fi +72" LHC . ( ? FOR FUTURE CASH REGISTERS. j i s I EXAM #2 3 ( i ;" 15 LHC 12 II r i 1 VERIFY LOCATION WITH STORE ¢ I 1 ti l i= w, _ ` s PART. 2/2) LGC PLANNING SETUP SUPERVISOR s 4-E1.1 5 I i 20 ! I ( /) TYP OF 4 16.226 5 H2B 21 18 ? t s } REF 1-E2 28 PRIOR TO INSTALLATION. TYP OF 4 -- I € LHC 20 LHCENLARGED' 16.232 v _� _._. .': t. UTILITY __._,_ . _ 4 +, € ?, EXAM #1 S PANEL ' w. A _ ... _,_ 16.232 _ I 12 i GFI, + +12" +12,. O _ - _.. ___ _. 2?" _ ,.__ ._._n_. 30 32 -- �•__ .._... N I � +12 I N L� � € , ,, y #... ,a LHC POWER LGCI LGC PROVIDE 1" CONDUIT (WITH P 4-E1.1 B 1t, .__ __,_.' _..,_ _.._.__' PLAINS _._. 2 -T1 PULL WIRE FROM DOOR w €t a E; 16.451 I w t 6'-0 6'-5" 6'-0" ) T __ HEADER UP TO STRUCTURE. 4 _. I _.._ . _ .._ +96" r _,_ _ T GFI PROVIDE 3/4„C _.. w TERMINATE WITH BUSHINGTO ABOVE w I I TYP OF 2 _ SCEILING FOR PEAKER WIRES_,___ .. _ w A VISION CENTER POWER PLAN HAIR CARE POWER PLAN SHEET CANOPY POWER PLAN 2 : 1/ E2.3 0 13 12 s k t 16.650 RT k. _. SPRINK 16.220 INSTALL PREFABRICATED ELECTRICAL 11 /17/04 t Z3\, 16.650 12"X12" SU amJ< f ,,,iaL1 D 00 0 _ ASSEMBLY WILL ARRIVE COMPLETELY f ! PRE WIRED AND IS AN ETL LISTED z V I m VERIFY LOCATION WITH STORE i PLANNING SET-UP SUPERVISOR $ PRIOR TO ROUGH -IN D4 OFFICE POWER PLAN +26"- TYP AT COUNTER 1/8" = V-0" = i I y 7 t!t i CONNECT TO PRE-INSTALLED LIGHT FIXTURE-�} s INSTALL FURNISHED POWER POLE WHEN EQUIPMENT IS SET IN PLACE. CONNECT FURNISHED CORD AND PLUG TO EQUIPMENT. MAKE FINAL I CONNECTIONS TO POWER POLE, RECEPTACLES, CORD f AND PLUG AS REQUIRED f TYP OF 3 VARIABLE SPEED CEILIP FAN SWITGF I f 11 LABEL "UPS" L1 U LID L1 U - SPRINKLER 2 1..G-301?, TYP OF 2 10 81 5 i RISERS E3 COORDINATE MOUNTING WISH CEILING GRID, 7 PLACE RECEPTACLES 6" APART AND LOCATED TO UTILITY CO. NEAREST TO CENTER OF RACK AS POSSIBLE, TRANSFORMER JOCKEYI PUMP YP LIU 7 CONTROLLER (1) 4" CONDUIT FOR 1 }(}FIRE PUMP CONTROLLER ALARM ;JUNCTION 4 TELEPHONE SERVICE 3 AIT HEATER MOUNT AS BOX „„__TELEPHONE CHASE HIGHAS POSSIBLE ALARM BOARD i � �} _._._..-.._MSB_- I 16.613 _l 3 _ O I 16.652 f 16.659 4 TYP ;OF 9. - E3 4 OF- RAC ACLES G WITH C IO GRI INSECT -1 PTACIES NEAREST TO CENTER, CON`fROL, C 0 �lA PLACE RECE , K AS POSSIBLE TYP OF 3 „ 9� ISROUN H1P2116H1A EDCi L1D�"� iy t J CHASE SECT 3 16.220 3-E3 f1D 9 11 8 INVOICING �b SECT 1 LPL 16.650 L1D2 L1U L1D TPL BRKR L1U L1U a - i ti J 4 a _' 11ppII� UPS UPG f ;, _. t 26, �MS BACKBOARD TELEPHONE B0 �` . I :, �� L1D MOUNTED SURE m 501D b, +44' 1 (PART. A/4 -. 12 _ _ „ ., 14 LID `1 !e FLOOR SCRUBBER 56 r- \\\ L1 D +48" GFI TYP OF 2 _ _ ._ 1 t�3�,..,{PART. 2 14`�+84" L1D L1D a F 3636 TRAINING L1D JANITOR a w 58 LID 2 c4 J a14(A:" J L L J4�" - _---- 1 1 9 RECIRCULATING PUMP. +60" DVIDE 30A 2 3 WIRE TWIST RECEPTACLE, X, PLUG AND CORD TYP OF 2 (D O f I 6 = 1'-0" J J 36 x36 40 (PART. 1/2 16.603j 44 DEDICATED' 16.650 L1D '^ ?. r+44"= CPAPE FrOP L1D 16.422 _Q ly 115 UPS L1 D T _'� 2/4) 6 2+ 1 T w ✓ .F _ A. ( 1D4 25 16.412 TYP )„ 11 _27 A x;' 1 O +24" L D ,LID J i 24 _ ?02 16.650 a 17 16.603 V L1D 22 20 16.650 16.425 +54" TYP 16.41`2 �, 293\31 16.6( L1D WH, +24 EFN i _ • r ' LID �" r runn�Ci 1 21 a," 2 t ? I� s LID 6` J J J J J J J J' J 31 J . _.. _. J 16.227 4- - BREAK ROOM GFi16 26+46" J J J J v{J_Q�CUSTOMER �� j SERVICE 61 } I 161 is T-=•- -, i L1D-610�� TL J 110 2. ,i 1, j 6 O _ k 8 I E3 TYP �w 11 w INSECT iz CONTROL, f " +96 _ �� `u J P 6.4,lil LID r t f �, 16.650 191 LD f 16.603 � GFI 38 A A 10 16.650 LI -D �. L1 6 i CLAIMS MANAGEMENT i' OFFIC�� I LAYAWAY 3j 6.410 LID N TYP ' 8 W I f 50 L1 D I �s a tw h C M -.Y e y „ v .. ♦ v 1 /4) 13'-10" , +72 SITE LIGHTING 9'-0" [ REF 1-E1.2 k t 16.650 RT k. _. SPRINK 16.220 INSTALL PREFABRICATED ELECTRICAL 11 /17/04 t Z3\, 16.650 12"X12" SU amJ< HINGED ,,,iaL1 D O I 16.652 f 16.659 4 TYP ;OF 9. - E3 4 OF- RAC ACLES G WITH C IO GRI INSECT -1 PTACIES NEAREST TO CENTER, CON`fROL, C 0 �lA PLACE RECE , K AS POSSIBLE TYP OF 3 „ 9� ISROUN H1P2116H1A EDCi L1D�"� iy t J CHASE SECT 3 16.220 3-E3 f1D 9 11 8 INVOICING �b SECT 1 LPL 16.650 L1D2 L1U L1D TPL BRKR L1U L1U a - i ti J 4 a _' 11ppII� UPS UPG f ;, _. t 26, �MS BACKBOARD TELEPHONE B0 �` . I :, �� L1D MOUNTED SURE m 501D b, +44' 1 (PART. A/4 -. 12 _ _ „ ., 14 LID `1 !e FLOOR SCRUBBER 56 r- \\\ L1 D +48" GFI TYP OF 2 _ _ ._ 1 t�3�,..,{PART. 2 14`�+84" L1D L1D a F 3636 TRAINING L1D JANITOR a w 58 LID 2 c4 J a14(A:" J L L J4�" - _---- 1 1 9 RECIRCULATING PUMP. +60" DVIDE 30A 2 3 WIRE TWIST RECEPTACLE, X, PLUG AND CORD TYP OF 2 (D O f I 6 = 1'-0" J J 36 x36 40 (PART. 1/2 16.603j 44 DEDICATED' 16.650 L1D '^ ?. r+44"= CPAPE FrOP L1D 16.422 _Q ly 115 UPS L1 D T _'� 2/4) 6 2+ 1 T w ✓ .F _ A. ( 1D4 25 16.412 TYP )„ 11 _27 A x;' 1 O +24" L D ,LID J i 24 _ ?02 16.650 a 17 16.603 V L1D 22 20 16.650 16.425 +54" TYP 16.41`2 �, 293\31 16.6( L1D WH, +24 EFN i _ • r ' LID �" r runn�Ci 1 21 a," 2 t ? I� s LID 6` J J J J J J J J' J 31 J . _.. _. J 16.227 4- - BREAK ROOM GFi16 26+46" J J J J v{J_Q�CUSTOMER �� j SERVICE 61 } I 161 is T-=•- -, i L1D-610�� TL J 110 2. ,i 1, j 6 O _ k 8 I E3 TYP �w 11 w INSECT iz CONTROL, f " +96 _ �� `u J P 6.4,lil LID r t f �, 16.650 191 LD f 16.603 � GFI 38 A A 10 16.650 LI -D �. L1 6 i CLAIMS MANAGEMENT i' OFFIC�� I LAYAWAY 3j 6.410 LID N TYP ' 8 W I f 50 L1 D I �s a tw h C M -.Y e y „ v .. ♦ v 1 /4) 13'-10" , +72 SITE LIGHTING 9'-0" [ REF 1-E1.2 RECESSED JUNCTION BOX. CONNECT THROUGH SMOKE DETECTOR ACCESSORY CONTACTS, CONFIGURED FOR FAIL-SAFE Z008 N OPERATION. REFER TO ARCHITECTURAL ` Or�WW� W DETAIL FOR JUNCTION BOX BACKING g? 6N"NU' LOCATION. 4 YINt�W wa,�aR 16.422 SMOKE DETECTOR: MOUNT WITHIN 12" OF f �.,iAA� ROOF STRUCTURE OR ON CEILING. PROVIDE) z Eliza-. od x;G ,'2 CONNECTIONS CONFIGURED FOR FAIL-SAFE) i OPERATION. .Z,Z�yV�� W " ' Ifs N J 16.425 TIMECLOCK RECEPTACLE: PROVIDE zm m WEATHERPROOF IN -USE LOCKABLE COVER 0 x AND MOUNT DIRECTLY BELOW TIME CLOCK DATA JUNCTION BOX. 16.452 SOUND SYSTEM CONDUIT: STUB CONDUIT (WITH PULL WIRE) FROM BELOW SHELVING UNIT TO BAR JOIST. PROVIDE BUSHING AT EACH END. 16.602 PROVIDE RECESSED ALARM JUNCTION BOX AT +80" WITH A CONDUIT TO ALARM JUNCTION BOX IN ADJACENT PUBLIC RESTROOM. 16.603 PROVIDE RECESSED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +80". (UNLESS NOTED OTHERWISE). 16.610 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +84" (UNLESS NOTED OTHERWISE). 16.613 ALARM AND PHONE BACKBOARD CONDUITS: PROVIDE (2) 2" CONDUITS (WITH PULL WIRE) FROM BACKBOARD TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND ROUTE TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" OVER CABLE TRAY. PROVIDE (1) 2" CONDUIT (WITH PULL WIRE) TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND EXTEND OUT OVER AISLEWAY. STUB CONDUITS 2" BELOW THE TOP OF BACKBOARD AT STENCILED CONDUIT ENTRY AREA AND TERMINATE WITH BUSHINGS. 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT SLEEVE WITH BUSHINGS ABOVE BAR JOIST (UNLESS NOTED OTHERWISE). 16.652 DATA AND PHONE CONDUITS: PROVIDE (3) 2" CONDUITS (WITH PULL WIRE) TO CABLE TRAY. ROUTE CONDUIT TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" OVER CABLE TRAY. PROVIDE (1) 2" CONDUIT (WITH PULL WIRE) TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND EXTEND OUT OVER AISLEWAY. STUB CONDUITS 6" BELOW DROP CEILING AND TERMINATE WITH BUSHINGS. 16.659 CONDUIT SLEEVE: PROVIDE 2" CONDUIT (WITH PULL WIRE) FROM 8" BELOW CEILING TO 12" ABOVE CEILING AND TERMINATE WITH I BUSHINGS. 16.661 DATA AND PHONE CONDUIT: PROVIDE CONDUIT SLEEVE THROUGH WALL AND ROUTE ABOVE BAR JOIST, UNLESS NOTED OTHERWISE ROUTE CONDUIT TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO CHECKED BY: MORE THAN 1" OVER CABLE TRAY. DRAWN BY: FILE NAME: E2.4 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 ISSUE BLOCK KEYNOTES 10/22/04 C. C. D. #1 16.220 INSTALL PREFABRICATED ELECTRICAL 11 /17/04 DISTRIBUTION CENTER (EDC). EQUIPMENT Z3\, 02/28/05 AND INTERNAL WIRING ARE SHOWN FOR amJ< 03/23/05 INFORMATION PURPOSES ONLY. THE ENTIRE 00 0 _ ASSEMBLY WILL ARRIVE COMPLETELY J n -waw w tn PRE WIRED AND IS AN ETL LISTED z V - W ASSEMBLY. Q W Q W ~a�50 16.227 ELECTRIC WATER COOLER RECEPTACLE: Fa¢�z CONCEAL WITHIN CABINET PER 0¢2z�W M \' MANUFACTURERS REQUIREMENTS. i iR wwIrw ,�,,,- 16.410 COUNTER MOUNTED DEVICES: STUB OUT OF =w�w;aR W 2 WALL AT +8". ROUTE FLEXIBLE METAL CONDUITS ALONG BACK WALL OF CABINET. MOUNT DEVICES WITHIN CABINET AT +8". VERIFY LOCATIONS WITH STORE PLANNING SETUP SUPERVISOR. 16.412 AUTOMATIC LAVATORY, URINAL AND WATER w N p4 00 CLOSET CONTROLS: PROVIDE JUNCTION N o 'oyQz BOXES, CONDUITS, RECEPTACLES AND LOW w a VOLTAGE WIRING (SHOWN DASHED) AS a<a�PkyrcHowVwA REQUIRED. COORDINATE EXACT LOCATIONS OK om�Xo�zv am AND REQUIREMENTS WITH MANUFACTURER'S i' Nc0>8Q«a-w� W wz-€,5'M RECOMMENDATIONS PRIOR TO INSTALLATION. Z 3g=m'�oWmw2oo�m 16.413 ROUTE ALL CUSTOMER SERVICE COUNTER zvaW�N��'3&�c=< R., T.__.-, CONDUITS IN FLEXIBLE METAL CONDUIT THRU x'=03 -1 as,�. �� c�ioz 5 �. 8 FURNISHED CHASE AT FLOOR. DATA, POWER a ooF ���S=�N� !,t AND I.G. CIRCUIT SHALL BE ROUTED INaa4O<bia�<o SEPARATE CONDUITS. 16 421 DOOR HOLD OPEN DEVICE• MOUNT IN RECESSED JUNCTION BOX. CONNECT THROUGH SMOKE DETECTOR ACCESSORY CONTACTS, CONFIGURED FOR FAIL-SAFE Z008 N OPERATION. REFER TO ARCHITECTURAL ` Or�WW� W DETAIL FOR JUNCTION BOX BACKING g? 6N"NU' LOCATION. 4 YINt�W wa,�aR 16.422 SMOKE DETECTOR: MOUNT WITHIN 12" OF f �.,iAA� ROOF STRUCTURE OR ON CEILING. PROVIDE) z Eliza-. od x;G ,'2 CONNECTIONS CONFIGURED FOR FAIL-SAFE) i OPERATION. .Z,Z�yV�� W " ' Ifs N J 16.425 TIMECLOCK RECEPTACLE: PROVIDE zm m WEATHERPROOF IN -USE LOCKABLE COVER 0 x AND MOUNT DIRECTLY BELOW TIME CLOCK DATA JUNCTION BOX. 16.452 SOUND SYSTEM CONDUIT: STUB CONDUIT (WITH PULL WIRE) FROM BELOW SHELVING UNIT TO BAR JOIST. PROVIDE BUSHING AT EACH END. 16.602 PROVIDE RECESSED ALARM JUNCTION BOX AT +80" WITH A CONDUIT TO ALARM JUNCTION BOX IN ADJACENT PUBLIC RESTROOM. 16.603 PROVIDE RECESSED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +80". (UNLESS NOTED OTHERWISE). 16.610 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +84" (UNLESS NOTED OTHERWISE). 16.613 ALARM AND PHONE BACKBOARD CONDUITS: PROVIDE (2) 2" CONDUITS (WITH PULL WIRE) FROM BACKBOARD TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND ROUTE TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" OVER CABLE TRAY. PROVIDE (1) 2" CONDUIT (WITH PULL WIRE) TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND EXTEND OUT OVER AISLEWAY. STUB CONDUITS 2" BELOW THE TOP OF BACKBOARD AT STENCILED CONDUIT ENTRY AREA AND TERMINATE WITH BUSHINGS. 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT SLEEVE WITH BUSHINGS ABOVE BAR JOIST (UNLESS NOTED OTHERWISE). 16.652 DATA AND PHONE CONDUITS: PROVIDE (3) 2" CONDUITS (WITH PULL WIRE) TO CABLE TRAY. ROUTE CONDUIT TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" OVER CABLE TRAY. PROVIDE (1) 2" CONDUIT (WITH PULL WIRE) TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND EXTEND OUT OVER AISLEWAY. STUB CONDUITS 6" BELOW DROP CEILING AND TERMINATE WITH BUSHINGS. 16.659 CONDUIT SLEEVE: PROVIDE 2" CONDUIT (WITH PULL WIRE) FROM 8" BELOW CEILING TO 12" ABOVE CEILING AND TERMINATE WITH I BUSHINGS. 16.661 DATA AND PHONE CONDUIT: PROVIDE CONDUIT SLEEVE THROUGH WALL AND ROUTE ABOVE BAR JOIST, UNLESS NOTED OTHERWISE ROUTE CONDUIT TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO CHECKED BY: MORE THAN 1" OVER CABLE TRAY. DRAWN BY: FILE NAME: E2.4 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 ISSUE BLOCK _ 10/22/04 C. C. D. #1 t+4 11 /17/04 C. C. D. #2 Z3\, 02/28/05 C.C.D. #13 amJ< 03/23/05 C.C.D. #15 00 0 _ J n -waw w tn v) m 0 m a 0 z V - W J Q W Q W ~a�50 > wozv, Fa¢�z 0¢2z�W M \' SEEO0z m�0 i iR wwIrw ,�,,,- a WATER O U Z W W Qa � umv) v amJ< a V1�JWNe 00 0 _ J n -waw w tn v) m 0 m a 0 z V - W J Q W Q W ~a�50 > wozv, Fa¢�z 0¢2z�W M \' SEEO0z m�0 i iR wwIrw ,�,,,- a =w�w;aR W 2 ENLARGED POWER PLANS SHEET: E2.4- �I CONTROL PANEL, +48" BY OTHERS PROVIDE 120V WIRING FROM JUNCTION BOX TO SMOKE DETECTOR AND MAKE FINAL TERMINATION AT SMOKE DETECTOR PROVIDE SURFACE MOUNTED JUNCTION BOX, +12" H PROVIDE SMOKE DETECTOR CENTERED N ON DOOR AND MOUNTED BETWEEN 4" AND 12" DOWN FROM ROOF STRUCTURE OR CEILING 0 N i i �l PROVIDE LOW VOLTAGE CONTROL/ INTERLOCK WIRING. FINAL TERMINATIONS BY OTHERS PROVIDE WIRING IN FLEXIBLE METAL CONDUIT BETWEEN JUNCTION BOXES AND CONTROL PANEL. FINAL TERMINATIONS AT CONTROL PANEL BY OTHERS PROVIDE WIRING IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. VERIFY WITH MANUFACTURER'S WIRING DIAGRAMS PRIOR TO ROUGH -IN 8/1VVVIVVIVIV I VL.VIIVV NTS 01.25.02 SATETE DI SH 6 NTA08.29.03 EP03 FROM PANELBOARD FEEDING UPS SYSTEM PROVIDE 250/125V, 50A TWISTLOCK 3 POLE 4 WIRE p°9 EP24 1 1/4" WEATHERHEAD POINT TOWARD SATELLITE MAST ROOF MEMBRANE (1) 1 1/4" GRC ATTACH TO STEEL JOIST IN TWO PLACES PROVIDE 3/8"x2 1/8" U -BOLTS WITH NUTS, LOCK WASHERS, AND ANGLE IRON BACK PLATES TYP PROVIDE BUSHING CONTRACTOR MILESTONE: ALL WORK SHALL BE COMPLETED FOR UPS SYSTEM INSTALLATION 2 WEEKS PRIOR TO POSSESSION DATE. THIS APPLIES TO BRANCH CIRCUIT WIRING FROM UPS PANELBOARDS TO LOADS SERVED THROUGHOUT THE STORE 5'-0" MAXIMUM MAINTENANCE BYPASS POD, CORD AND PLUGS FURNISHED BY OWNER, INSTALLED BY CONTRACTOR J RECEPTACLE L_ a U. o w 0 I FINISHED FLOOR Tk 3 UPS S I NTS UPS SYSTEM, CORD AND PLUG FURNISHED BY OWNER, INSTALLED BY CONTRACTOR 03.28.03 EP09 TO UPS PANELBOARD PROVIDE JUNCTION BOX AT 3'-0" AFF L PROVIDE 6'-0" #6/4 SO CORD AND 250/125V, 50A TWISTLOCK 3 POLE, 4 WIRE PLUG —UPS OUTPUT NEUTRAL IS BONDED TO EARTH GROUND INSIDE UPS PROVIDE GROUNDING ELECTRODE CONDUCTOR 7 LGC 26 N.T.S. SWITCH OFF �•—•—• SWITCH OFF ■rte PROVIDE A TEMPORARY COVER FOR OPENING - (1) 1 1/4" GRC ATTACH TO STEEL JOIST IN TWO PLACES PROVIDE 3/8"x 2 1/8" U -BOLTS WITH NUTS AND LOCK WASHERS AND ANGLE IRON BACK PLATES — PROVIDE BUSHING c SEN SORD MAST 05.25.EP01 PROVIDE WEATHERPROOF 4 11/16"x2 1/8" BOX FOR AUDIO/VISUAL DEVICE SPRINKLER SYSTEM AUDIO/VISUAL DEVICE (BY OTHERS) WATER FLOW SWITCH (BY SPRINKLER CONTRACTOR) PROVIDE 1/2" LIQUID TIGHT CONDUIT SUPERVISORY (TAMPER) SWITCH (BY SPRINKLER CONTRACTOR) SWITCH SHALL BE LOCATED IN THE 12 O'CLOCK POSITION PROVIDE 1 1/4" PIPE SLEEVE. CAULK AND MAKE WATER TIGHT— PROVIDE IGH T PROVIDE 4 11/16"x2 1/8" BOX VOICE/DATA ROUGH -IN SCHEDULE 05.31.02 ES02 DROP ROUGH -IN NOTES: -a FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT STUBBED 12" ABOVE LAY -IN CEILING. -b FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT ROUTED TO NEAREST ACCESSIBLE CEILING SPACE. -c SURFACE MOUNT JUNCTION BOX AT +66" (UNO) WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE. -d SURFACE MOUNT JUNCTION BOX AT +60" WITH (1) 3/4" CONDUIT STUBBED TO CONDUIT SLEEVE. -e SURFACEMOUNTWEATHER PROOF JUNCTION BOX AT TRUSS WITH (1) 3/4" CONDUIT ROUTED TO SEASONAL SHOP ACCESSIBLE FLUORESCENT FIXTURE CEILING -f MOUNT JUNCTION BOX WITHIN ENCLOSURE WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE. PROVIDE A TEMPORARY COVER FOR OPENING - (1) 1 1/4" GRC ATTACH TO STEEL JOIST IN TWO PLACES PROVIDE 3/8"x 2 1/8" U -BOLTS WITH NUTS AND LOCK WASHERS AND ANGLE IRON BACK PLATES — PROVIDE BUSHING c SEN SORD MAST 05.25.EP01 PROVIDE WEATHERPROOF 4 11/16"x2 1/8" BOX FOR AUDIO/VISUAL DEVICE SPRINKLER SYSTEM AUDIO/VISUAL DEVICE (BY OTHERS) WATER FLOW SWITCH (BY SPRINKLER CONTRACTOR) PROVIDE 1/2" LIQUID TIGHT CONDUIT SUPERVISORY (TAMPER) SWITCH (BY SPRINKLER CONTRACTOR) SWITCH SHALL BE LOCATED IN THE 12 O'CLOCK POSITION PROVIDE 1 1/4" PIPE SLEEVE. CAULK AND MAKE WATER TIGHT— PROVIDE IGH T PROVIDE 4 11/16"x2 1/8" BOX VOICE/DATA ROUGH -IN SCHEDULE 05.31.02 ES02 DROP ROUGH -IN NOTES: -a FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT STUBBED 12" ABOVE LAY -IN CEILING. -b FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT ROUTED TO NEAREST ACCESSIBLE CEILING SPACE. -c SURFACE MOUNT JUNCTION BOX AT +66" (UNO) WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE. -d SURFACE MOUNT JUNCTION BOX AT +60" WITH (1) 3/4" CONDUIT STUBBED TO CONDUIT SLEEVE. -e SURFACEMOUNTWEATHER PROOF JUNCTION BOX AT TRUSS WITH (1) 3/4" CONDUIT ROUTED TO SEASONAL SHOP ACCESSIBLE FLUORESCENT FIXTURE CEILING -f MOUNT JUNCTION BOX WITHIN ENCLOSURE WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE. -9 SURFACE MOUNT WEATHER PROOF JUNCTION BOX 6" BELOW CEILING WITH (1) 3/4" CONDUIT STUB TO ACCESSIBLE CEILING SPACE. -h FLUSH MOUNT 2 1/8" DEEP JUNCTION BOX WITH DOUBLE GANG PLASTER RING AT +20" WITH (2) 3/4" CONDUITS STUBBED 12" WH ABOVE LAY -IN CEILING. SCHEDULE GENERAL NOTES: (1) ALL JUNCTION BOXES SHALL BE DOUBLE GANG WITH SINGLE GANG PLASTER RING UNLESS NOTED OTHERWISE ON SCHEDULE. (2) ALL JUNCTION BOXES TO BE ROUGHED IN AT SCHEDULED HEIGHT UNLESS NOTED OTHERWISE ON DRAWINGS. (3) ALL CONDUITS SHALL BE TERMINATED WITH BUSHINGS. (4) PROVIDE PULL WIRE WITH EACH EMPTY RACEWAY (JUNCTION BOX/CONDUIT) INSTALLED. (5) CONDUIT RUNS SHALL HAVE NO MORE THAN 90 DEGREES OF TRANSITION BETWEEN PULL BOXES. (6) WHERE CONDUIT(S) TRAVERSE AREAS WITH CEILINGS OPEN TO STRUCTURE, CONDUIT(S) SHALL BE CONCEALED AS WELL AS POSSIBLE FROM VIEW FROM CUSTOMER AREA. (7) FOR CONDUIT RUNS SCHEDULED WITH 1-1/2" OR LARGER CONDUIT UTILIZE LARGE RADIUS SWEEPS AT POINTS OF TRANSITION. (8) ACCESSIBLE CEILING SPACE SHALL BE CONSIDERED 12 INCHES ABOVE A LAY -IN CEILING OR ABOVE BAR JOIST ACCESSIBLE BY A SCISSOR LIFT FOR AREAS OPEN TO STRUCTURE. (9) WHEN CABLE TRAY IS NOT PROVIDED, STUB CONDUIT(S) TO TOP SIDE OF BOTTOM CHORD OF JOISTS AND EXTEND TO ACCESSIBLE CEILING SPACE ON SALES FLOOR. ROLLSEAL DOOR LIMIT SWITCHES PROVIDED WITH DOOR. NORMALLY CLOSED HELD OPEN BY DOOR BEING IN CLOSED POSITION. !-1 LGC-1,3 I-) LGC-5,7 C2 , 11 .�LGC-9,11 �l LGC-13,15 J LGC-17,19 10'-0" MINIMUM EXTERIOR WALL GC EXHAUST FANS -SURFACE MOUNTED ENCLOSED CONTACTOR 3OA/24OV/6POLE/ 120V COIL/NEMA 1/ ELECTRICALLY HELD GC EXHAUST FANS PROVIDE 1/2" CONDUIT, CAULK AND MAKE WATERTIGHT ZZ PROVIDE 4 11/16"x 2 1/8" BOX PROVIDE 3/4" CONDUIT TO 12"x12" ENCLOSURE --PROVIDE 1/2" FLEXIBLE CONDUIT FOR 24 VOLT WIRING -=----PROVIDE 1/2" FLEXIBLE CONDUIT PROVIDE ALARM JUNCTION BOX FOR EACH VALVE AND STUB -OUT SPRINKLER RISER PROVIDE EMPTY CONDUITS) WITH PULL STRING FOR REMOTE SYSTEM DEVICES AS REQUIRED. _ COORDINATE WITH CIVILS SPRINKLER SYSTEM TAMPER 2 AI 10.31.03 EF11-2 7��'8I 4) NT' NTS CONDU OTHER BOXES CONDU EXPOSE JUN CTI CONDUi i t VK JMVKt DETECTOR TEST -RESET SWITCH AS SHOWN ON DRAWINGS -- FLEXIBLE METAL CONDU CEILING COVERPLATE RECEPTACLE 04.26.02 ;�I7��L5I�C NOTE: CONCEAL CONDUIT AND USE FLUSH BOX ON WRAPPED COLUMN � COLU M NTS GENERAL NOTES ELECTRICAL SYMBOLS 01.30.04 LEGEND ES03 1. PROVIDE SEALS AT RACEWAY PENETRATIONS AS (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) FOLLOWS: SYMBOL DESCRIPTION A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE STOPPING. B. NEUTRALIZATION AREA: SEAL PER KD / O INCANDESCENT HID FIXTURE (WALL MOUNTED// CEILING MOUNTED) SS SHOWN ON DRAWINGS MECHANICAL DETAIL. FLUORESCENT FIXTURE SMOKE DETECTOR C. FREEZER/COOLER BOXES: SEAL WITH HORN / STROBE RH RADIANT HEATER FLUORESCENT FIXTURE, EXPANDING FOAM SEALANT, WH 2. PROVIDE A SEPARATE EQUIPMENT GROUNDING NIGHT LIGHT RECEPTACLE MOUNTED ❑ ENCLOSED FREEZER LIGHT CONDUCTOR (SIZE PER NEC)IN PVC TYPE CONDUIT, POWER CIRCUITS, ISOLATED GROUND J ON DRAWINGS e—(E) TRACK LIGHTING CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING CONDUCTOR. 3. WIRING DEVICES: DEVICE MOUNTING HEIGHTS / ® EXIT FIXTURE (WALL MOUNTED/CEILING MOUNTED) ARE FROM FINISHED FLOOR TO CENTER OF EMERGENCY FIXTURE OUTLET BOX UNLESS NOTED OTHERWISE ON -ow< O $ SWITCH, SINGLE POLE PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH MASONRY: A. SWITCHES +46" B. RECEPTACLES +20" $3 SWITCH, 3 -WAY C. VOICE/DATA (REFER TO SCHEDULE) 4. WIRING SHALL INCLUDE FINAL CONNECTION TO $4 SWITCH, 4-W?. ALL EQUIPMENT IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. $K SWITCH, KEYED 5. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE PANELBOARD IDENTIFICATION $D SWITCH, DIMMER SCHEDULES. 6. BRANCH CIRCUIT CONDUCTORS SHALL BE �m $VS SWITCH, VARIABLE SPEED MINIMUM #12 AWG UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH CIRCUITS $M SWITCH, MANUAL MOTOR HAVE #8 AND LARGER WIRE SPECIFIED, #10 $OS SWITCH, OCCUPANCY SENSOR AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION (15 -FT MAXIMUM). #DS SWITCH, BI -LEVEL 7. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND DERATE CURRENT CARRYING OCCUPANCY SENSOR Ip RECEPTACLE, DUPLEX CONDUCTORS PER NEC. 8. CONDUITS EXTENDING BEYOND EXTERIOR WALL: RECEPTACLE, DUPLEX, MOUNTED HORIZONTALLY STUB OUT 2'-0" BELOW GRADE TO 5'-0"Q BEYOND EXTERIOR WALLS UNLESS NOTED OTHERWISE, COORDINATE LOCATION AND PROVIDE CONNECTION TO SITE CONDUITS. ❑® RECEPTACLE, DUPLEX FLUSH FLOOR 9, DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE: ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND PHONE CABLING TO RECEPTACLE, DUPLEX ISOLATED GROUND FLUSH FLOOR RECEPTACLE, DOUBLE DUPLEX BE INSTALLED 3 WEEKS PRIOR TO CONTRACT SUBSTANTIAL COMPLETION DATE. (� RECEPTACLE, DUPLEX 1f ISOLATED GROUND RECEPTACLE, DOUBLE DUPLEX, ISOLATED GROUND 9 RECEPTACLE, SIMPLEX TWIST LOCK, (�1 RECEPTACLE, SIMPLEX TWIST LOCK, �Y ISOLATED GROUND RECEPTACLE, DUPLEX TWIST LOCK, (�1 RECEPTACLE, DUPLEX TWIST LOCK, ISOLATED GROUND ® RECEPTACLE, SPECIAL Cp RECEPTACLE, SIMPLEX RECEPTACLE, PLUG -MOLD O JUNCTION BOX (WALL MOUNTED/CEILING MOUNTED) O ALARM JUNCTION BOX, (WALL MOUNTED/CEILING MOUNTED) ALARM JUNCTION BOX, ® FOR REMOTE TEST/RESET (WALL MOUNTED/CEILING MOUNTED) EQUIPMENT CONNECTION POINT (PROVIDED WITH EQUIPMENT) Et NON-FUSED DISCONNECT Eh FUSED DISCONNECT "EUTRT"D CIRCUIT, CONCEALED IN WALLS OR "_o� CEILING, E INDICATES EXISTING ,.1. /r' WIRING CIRCUIT, CONCEALED IN SLAB FLOOR E INDICATES EXISTING WIRING CIRCUIT, EXPOSED, PROVIDE TIE WIRES FOR E INDICATES EXISTING WIRING BOX HANGER - THIS IS NOT PART OF THE CEILING I -I CONDUIT SLEEVE SUSPENSION TYP = FLUSH MOUNTED PANELBOARD SUPPORT CLIP TO TIE WIRE AT MAXIMUM 4'-6" SURFACE MOUNTED PANELBOARD SPACING. ROUTE CONDUIT TO JUNCTION BOX AT BAR JOIST MANUFACTURED WIRING SYSTEM EP23 CONDUITS SHALL STUB UP ABOVE TOP OF BOTTOM CHORD OF JOIST T CEILING FAN ALARM JUNCTION BOX MOTOR AND CONDUIT FOR r.._.RTU SMOKE DETECTOR PUSH BUTTON POPIT DEVICE AS I © GFI SS SHOWN ON DRAWINGS SAIL SWITCH JUNCTION BOX O2 SMOKE DETECTOR Rm HORN / STROBE RH RADIANT HEATER +74 INCHES UNIT HEATER WH WATER HEATER WP RECEPTACLE MOUNTED ON COLUMN FACING REAR Q OF STORE AS SHOWN J ON DRAWINGS 04.26.02 EP25 - TELEPHONE ® TELEPHONE, FLUSH FLOOR CF CEILING FAN CO MOTOR ❑O TELEPOWER POLE El PUSH BUTTON 6 BUZZER GFI SS IG SAIL SWITCH JUNCTION BOX O2 SMOKE DETECTOR Rm HORN / STROBE CF CEILING FAN CO CHECK OUT CW CASH/WRAP EF EXHAUST FAN G GROUND GFI GROUND FAULT CIRCUIT INTERRUPTER IG ISOLATED GROUND REC REFRIGERATION ELECTRICAL CONTRACTOR RC REFRIGERATION CONTRACTOR RH RADIANT HEATER UH UNIT HEATER WH WATER HEATER WP WEATHER PROOF Lli N OQ ppm Wi R mWuwia�zwm z¢ w Zoo Iri ?DN w m a��oir z iro � Q �y�om,-�ww�zv,am wz� < Zozado aSWoo�awWw� mya„, UOmO m Oy S'w-,°'5GadA-,< 4"C wmwa o�n'�wg rcz�NwFwwwVa�a amor=w���5x¢�o� F- Nw�.�Op� U) Fwm§z J zww Q4IQKKQ� 1 •-i 1 " C"J F CC) CD W Oz a Qi � E-+ I_ cx ISSUE BLOCK lAl 10/22/04 CHECKED BY: z(n o DRAWN BY: OQ `o a w� a FILE NAME: w1' ,w4°oow E ooz m.lneo PROTO CYCLE: a� mno Z. W �o6,; -AMMO Elzmo..,..... ZYO1 < _ FLj OWKWQ ^�UJ FLL J w Q W ZNw J o xw--m U � 1 •-i 1 " C"J F CC) CD W Oz a Qi � E-+ I_ cx ISSUE BLOCK lAl 10/22/04 CHECKED BY: DRAWN BY: FILE NAME: E3 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 K OU zw w O �F U m o O O W U '32: aoDa Z J r J w Q apo x � J a w Q w w n <o mom o S w c> Q J cy-w o ma-Z� 00 FQazwz 4 J Upgoa w -ow< O w m N S N Z uj Z) of OwwF =w���z ¢ w - aU)a_ma rn o ELECTRICAL DETAILS, SYMBOLS, AND SCHEDULES 1 11 1 SHEET: E3 i COORDINATE PANEL LOCATION WITH EDC FRAMED OPENING AND COURSED WITH THE CMU PORTABLE GE % NTS EDC WALL 3 j j NEMA 4 24"x 24"x 8" FLUSH MOUNTED I ENCLOSURE SEAL PANEL HOFFMAN #CFM24248LG FLANGE TO j CMU BLOCK_r- j 24% 24" EDC FRAMED OPENING PADLOCKING �� HANDLE 1 1 6" CHASE NIPPLE WITH HOFFMAN L LOC;:"1'.;T A";D IA,CIIILA TCS BUSHING TYP OF 4 i r I i EDC SKID FINISH `;! o ' 00 GRADE Qv— -- CONCRETE A FLOOR SLAB ATOR "QC1) CABLE RACEWA� 11.28.03 CPQ MSB 480/277V, 3 PH, 4W SERVES: MAIN SERVICE 3000A, M. C. B. LOCATION: EDC1 (7) AIC, FULLY RATED GROUND BUS PANEL PROVIDED WITH EDC FLOOR MOUNT SECTION DESCRIPTION VOLT -AMP PER PHASE TOTAL KVA TOTAL AMPS FEEDER AMPS 1 GENERATOR BREAKER ALUMINUM FEEDERS 2 MAIN BREAKER (EMT) GROUND ALUMINUM FEEDERS 3 DISTRIBUTION AND ALUMINUM FEEDERS 3,037 3,653L2,d977TOTALS FEEDER AMPACITY O. OF SETS COPPER CONDUCTORS THVlrll) PHASE & NEUTRAL GROUND & I.G. PER NEC ARTICLE 220 - 6 6 6 6 6 4 4 4 14 4 2 2/2" 2 1 1 1 1/0 1/0 2/0 3/0 3/0 PROPERTIES 4OREMT OF V979.248 3,037 3,653 B1 B2 B3 B4 B5 B6 B10 612 614 615 B17 B18 B19 B20 821 B22 NEC 1/2" 3/4" 1" 1-1 1-1/4" 2" 2-1/2"/2" 2" 2" 2" 2-1/2" 2-1 2" / 2-1/2" 3" 2-1/2" EDITION, CONDITIONS - 1" 1" 2-1 /2" 2-1/2" 2-1/2" 3" 3-12" / 2-1/2' 9, MAY PREQUIRE Cl C2 C3 C17 C18 C19 C20 C21 C22 B ATER 3/4" 3/4" 1" 2" 2-1/2" 2-1/2 3" 3 " 2-1/2" LARGER CONDUIT, (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FAULT CURRENT FOR INTERRUPTING RATINGS ELECTRICAL UNE -LINE FEEDER SCHEDULE ES04-1 06.30.02 _ _- UTILITY CONTACT: SIZE (75'C) ALUMINUM CONDUCTORS (XHHWTO PHASE & NEUTRAL GROUND & I.G. 3 PHASE NO' CONDUCTORS AND GROUND COPPER FEEDERS ALUMINUM FEEDERS CONDUIT 3 PHASE NEUTRAL, NO. SIZE CONDUCTORS, AND COPPER FEEDERS (EMT) GROUND ALUMINUM FEEDERS 3 PHASE NEUTRAL, ISOLATED NO. CONDUCTORS, GROUND, GROUND COPPER FEEDERS AND ALUMINUM FEEDERS METER BASE FURNISHED BY UTILITY, INSTALLED BY CONTRACTOR FEEDER CONDUCTOR FEEDER AMPACITY O. OF SETS COPPER CONDUCTORS THVlrll) PHASE & NEUTRAL GROUND & I.G. - 6 4 4 2 1 1/0 2/0 3/0 1 4f0 250kcmil 300kcmil 350kcmil 3f0 4f0 750kcmil 250kcmil 300kcmil 350kcmil 500kcmil 750kcmil 400kcmil CONDUCTOR , , AND QUANTITY - 6 6 6 6 6 4 4 4 14 4 2 2/2" 2 1 1 1 1/0 1/0 2/0 3/0 3/0 PROPERTIES 4OREMT OF Al A2 A3 A4 A5 A5 A8 A9 A10 A11 Al2 A14 A15 A16 A17 A18 A19 A20 A21 A22 LUGS 1/2" 3/4" 3/4" 3/4» 1" V, 1-1/4" 1-1 1-1 /2" 2" 2" 1-1 /2" 1-1 /2" 2-1/2" 2" 2" 2 " 2-1/2" 2-1/2" 2-1/2" N I WITH STED 140% WITH EDC - 3/4" 1" 1" 7-1/4" 1-1/4" 2" 2" 1-1/2" 2" 2" 2-1/2" 2-12" / 2-1/2" 3" 2-1/2" THE CURRENT FILL. OTHER VENDOR B1 B2 B3 B4 B5 B6 B10 612 614 615 B17 B18 B19 B20 821 B22 NEC 1/2" 3/4" 1" 1-1 1-1/4" 2" 2-1/2"/2" 2" 2" 2" 2-1/2" 2-1 2" / 2-1/2" 3" 2-1/2" EDITION, CONDITIONS - 1" 1" 2-1 /2" 2-1/2" 2-1/2" 3" 3-12" / 2-1/2' 9, MAY PREQUIRE Cl C2 C3 C17 C18 C19 C20 C21 C22 B ATER 3/4" 3/4" 1" 2" 2-1/2" 2-1/2 3" 3 " 2-1/2" LARGER CONDUIT, - 1" 1-1/4" /2" 2-1 /2" 2-1 j2" /2" /2" 2-1 2 / 2-1/2" 2-1/2 3-1 2» / 3" AND 30 1 10 10 _10 50 1 8 60 1 6 10 65 1 6 8 85 1 4 8 100 1 3 8 115 1 2 6 130 1 1 6 150 1 1/0 6 175 1 2/0 6 200 1 3/0 6 230 1 4/0 4 250 1 250kcmil 4 300 2 1/0 4 350 2 2/0 3 380 1 500kcmil 3 400 2 3/0 3 460 2 4/0 2 500 2 250kcmil 2 600 2 350kcmil 1 760 800 2 3 500kcmil 300kcmil 1/0 1/0 NOTES: 1. CONDIT CONDUIITUAREAS SIZED 2. COORDINATE SIZE PER NEC. BASED CHAPTER LASTED CO SIZE, TYPE PRIMARY SERVICE REF CIVIL PLANS SERVICE LATERAL CONDUCTORS PROVIDED BY UTILITY COMPANY 3 SU TI 07.27.01 EP26 SECONDARY TRENCH AND BACKFILL, CONDUITS AND CONDUCTORS PROVIDED BY CONTRACTOR SWITCHBOARD NOTES 1. THE SWITCHBOARD IS PART OF A UL LISTED (1) #3f0 BARE COPPER SERIES RATED SYSTEM THAT REQUIRES THE EXTERIOR DOWN STREAM BREAKERS TO BE TESTED WITH WALL— THE SWITCHBOARD AS A COMPLETE UL LISTED (1) #6 BARE COPPER TO SYSTEM. THE MANUFACTURER WILL PROVIDE VERTICAL TY TELEPHONE EQUIPMENT SPECIFIC BREAKER TYPES (CATALOG NUMBERS) TO COMPLY WITH THE TESTS FOR A SERIES BUILDINGRATED SYSTEM. ANY REPLACEMENT BREAKERS STEEL SUPPLIED SHALL MATCH EXISTING TYPES MAIN 1 SWITCHBOARD ,-NEUTRAL BUS (CATALOG NUMBERS) SUPPLIED BY THE FACTURER FAILURE TO BOND TO BUILDING STEEL WITH EXOTHERMIC WELD FINISHED GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH LOCAL CODES AND/OR AUTHORITY HAVING JURISDICTION GROUNDING ELECTRODE CONDUCTOR SHALL EXIT FOUNDATION AT EDC GROUND CHASE 43/0 BARE COPPER CONDUCTOR FROM NEUTRAL BUS. EXTEND 20'-O» AT BOTTOM OF FOUNDATION WITH MINIMUM OF 2" COVERAGE IF WATER SERVICE LINE IS METAL, IT MUST BE BONDED TO GROUNDING ELECTRODE SYSTEM WITH A #3/0 THWN COPPER CONDUCTOR. CT'S FURNISHED BY UTILITY, INSTALLED BY CONTRACTOR _ _- UTILITY CONTACT: GY XCEDOYLEE ERLEFSON ELECTRICAL SYSTEM. CT'S LOCATED IN CT/CONNECTION CABINET 2. PROVIDE GROUND FAULT TESTING OF THE ADDRESS: 118 DUNDAS ROAD ST CT/CONNECTION CABINET FURNISHED AND INSTALLED BY CONTRACTOR REQUIRED TO OBTAIN THE FOLLOWING SETTINGS. MONTICELLO, MN 55362 THE GROUND FAULT RELAY'S CURRENT METER BASE FURNISHED BY UTILITY, INSTALLED BY CONTRACTOR SENSITIVITY SHALL BE SET AT 40% OF THE PHONE: 763-271-6423 UTILITY METER FURNISHED BY UTILITY, INSTALLED BY UTILITY s FAX: 763-295-5345 CONDUCTORS PROVIDED BY METER LOCATION AT REAR WALL HAVING JURISDICTION. EMAIL: doyle.e.tollefsonOxcelenergy.com FIRE PUMP KEYNOTES METERING CONDUIT PROVIDED BY UTILITY COMPANY 1. SWITCHBOARD MFR. SHALL PROVIDE PLACARD ON CABINET SWITCHBOARD THAT STATES "SERVICE NO. 1 OF DilCT - PAD MOUNTED CT/CONNECTION CABINET PROVIDED BY CONTRACTOR PER XCEL ENERGY (8) SETS OUTSIDE WALL �� "STANDARD FOR ELECTRIC INSTALLATION" i FIRE PUMP CONTROLLER THAT STATES "FIRE EACH IN ���"j SECONDARY TERMINATIONS z (8) SETS OF (4) 750kcmil ALUMINUM �v BY UTILITY COMPANY EACH IN 4" CONDUIT SERVICE TRANSFORMER I REF CIVIL PLANS SECONDARY TERMINATIONS PRIMARY TERMINATIONS BY CONTRACTOR REF CIVIL PLANS CONTINUOUS TRANSFORMER MSB AND CONNECTION CABINET PAD I REF CIVIL PLANS �I i 4 PRIMARY SERVICE REF CIVIL PLANS SERVICE LATERAL CONDUCTORS PROVIDED BY UTILITY COMPANY 3 SU TI 07.27.01 EP26 SECONDARY TRENCH AND BACKFILL, CONDUITS AND CONDUCTORS PROVIDED BY CONTRACTOR SWITCHBOARD NOTES 1. THE SWITCHBOARD IS PART OF A UL LISTED (1) #3f0 BARE COPPER SERIES RATED SYSTEM THAT REQUIRES THE EXTERIOR DOWN STREAM BREAKERS TO BE TESTED WITH WALL— THE SWITCHBOARD AS A COMPLETE UL LISTED (1) #6 BARE COPPER TO SYSTEM. THE MANUFACTURER WILL PROVIDE VERTICAL TY TELEPHONE EQUIPMENT SPECIFIC BREAKER TYPES (CATALOG NUMBERS) TO COMPLY WITH THE TESTS FOR A SERIES BUILDINGRATED SYSTEM. ANY REPLACEMENT BREAKERS STEEL SUPPLIED SHALL MATCH EXISTING TYPES MAIN 1 SWITCHBOARD ,-NEUTRAL BUS (CATALOG NUMBERS) SUPPLIED BY THE FACTURER FAILURE TO BOND TO BUILDING STEEL WITH EXOTHERMIC WELD FINISHED GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH LOCAL CODES AND/OR AUTHORITY HAVING JURISDICTION GROUNDING ELECTRODE CONDUCTOR SHALL EXIT FOUNDATION AT EDC GROUND CHASE 43/0 BARE COPPER CONDUCTOR FROM NEUTRAL BUS. EXTEND 20'-O» AT BOTTOM OF FOUNDATION WITH MINIMUM OF 2" COVERAGE IF WATER SERVICE LINE IS METAL, IT MUST BE BONDED TO GROUNDING ELECTRODE SYSTEM WITH A #3/0 THWN COPPER CONDUCTOR. (4) #2/0 COPPER 2" CONDUIT --- ---------- ORIGINAL SYSTEM MANU SUPPLY THE CORRECT BREAKERS WILL VOID MAIN BONDING JUMPER THE SERIES SYSTEM RATING OF THE COMPLETE INCOMING ELECTRICAL SYSTEM. gSHU;NTTRIP 2. PROVIDE GROUND FAULT TESTING OF THE EQUIPMENT GROUND BUS PRIMARY ST CHECK FACTORY SETTINGS AND ADJUST AS CONDUIT ABOVE ROOM SHALL BE REQUIRED TO OBTAIN THE FOLLOWING SETTINGS. FINISHED FLOOR THE GROUND FAULT RELAY'S CURRENT BREAKER SENSITIVITY SHALL BE SET AT 40% OF THE KIRK KEY MAIN SWITCH AMPERE RATING. THE TIME DELAY UTILITY SHALL BE SET TO THE MAXIMUM. PRIOR TO s FINAL INSPECTION, PROVIDE A WRITTEN COPY TRANSFORMER CONDUCTORS PROVIDED BY UTILITY HAVING JURISDICTION. COMPANY (SEE SCHEDULE FIRE PUMP KEYNOTES KWH 1. SWITCHBOARD MFR. SHALL PROVIDE PLACARD ON CABINET SWITCHBOARD THAT STATES "SERVICE NO. 1 OF DilCT - KWH (8) SETS OF (4) 500kcmil COPPER i FIRE PUMP CONTROLLER THAT STATES "FIRE EACH IN 4" CONDUIT OR OF 2 SERVICES. SERVICE NO. 1 IS LOCATED IN z (8) SETS OF (4) 750kcmil ALUMINUM EACH IN 4" CONDUIT (4) #2/0 COPPER 2" CONDUIT --- ---------- ORIGINAL SYSTEM MANU SUPPLY THE CORRECT BREAKERS WILL VOID MAIN BONDING JUMPER THE SERIES SYSTEM RATING OF THE COMPLETE EQUIPMENT BONDING JUMPER ELECTRICAL SYSTEM. gSHU;NTTRIP 2. PROVIDE GROUND FAULT TESTING OF THE EQUIPMENT GROUND BUS SERVICE DISCONNECTS TO COMPLY WITH NEC. ST CHECK FACTORY SETTINGS AND ADJUST AS CONDUIT ABOVE ROOM SHALL BE REQUIRED TO OBTAIN THE FOLLOWING SETTINGS. FINISHED FLOOR THE GROUND FAULT RELAY'S CURRENT BREAKER SENSITIVITY SHALL BE SET AT 40% OF THE KIRK KEY MAIN SWITCH AMPERE RATING. THE TIME DELAY Q SHALL BE SET TO THE MAXIMUM. PRIOR TO s FINAL INSPECTION, PROVIDE A WRITTEN COPY TYP OF PERFORMANCE TEST TO THE AUTHORITY HAVING JURISDICTION. ULZj (SEE SCHEDULE FIRE PUMP KEYNOTES KWH 1. SWITCHBOARD MFR. SHALL PROVIDE PLACARD ON SECTION 1 SWITCHBOARD THAT STATES "SERVICE NO. 1 OF SECTION 3 1 2 SERVICES. SERVICE NO. 2 IS LOCATED IN THE FaQJz FIRE PUMP ROOM-, IN ONE INCH LETTERS. 2. CONTRACTOR SHALL PROVIDE PLACARD NEAR i FIRE PUMP CONTROLLER THAT STATES "FIRE iR PUMP DISCONNECTING MEANS - SERVICE NO. 2 OF 2 SERVICES. SERVICE NO. 1 IS LOCATED IN z MAIN ELECTRICAL ROOM", IN ONE INCH LETTERS. (4) #2/0 COPPER 2" CONDUIT --- ---------- PUMP CONTROLLERS ARE PART OF A PREFABRICATED PUMP PACKAGE i i 1 TO PANEL HIB i i i 1 I I j � I � FIRE r1pou CKEY 31,466 PUMP 2,606 MPTRL FIRE PUMP, TRL JOCKEY PUMP, 1 1 #4 Cu GROUNDING 100 HP, 2 HP, ELECTRODE 480/3 480/3 CONDUCTOR. = 2 i --------------------------' i 1 i GROUND FIRE PUMP 1 II SERVICE SIMILAR TO 1 r--------------' DETAIL 2-E4 I � 1 A20 I 7,838 622 8,694 1 i I 1 I FIRE PUMP ROOM (2) #4 AND (1) #8 GND i `---------------------------- i PANEL PANEL COPPER IN 1" C. OR H1A H16 (2) #2 AND (1) #6 GND 1 UNDERGROUND 1 ALUMINUM IN 1" C. _________�----------- ---r--- �_il ---------- i ------------------------------------- 11 1 NOTE: DASHED LINE INDICATES FACTORY WIRING TYP 1 i B11 34,900 B11 i 6,699 1 I �7,68%� A8134,071 \/ I PANEL PANEL i TPL �N TlD 480V H1 P1 H1P2 A19 14,157 A38 13,575 480V ----- I 3" #8 CU i 25 KVA #2 CU I� 75 KVA PROVIDE EXOTHERMIC 1 ` 208Y/120V i GND 1 240/120V GND _____ - I MAIN MAIN WELD TO NEAREST _ is - i — AVAILABLE BUILDING UPSPANEL PANEL 1STEEL PER NEC, TYP i C12 i 8 KVA (COMPRESSOR (COMPRESSOR #8 CU(3) #1/0 AND (2) #6 GND/IG i GNDHOUSE #1) HOUSE #2) COPPER IN 1-1/2" C. i P2NSECT.EL OR D(3) #3/0 AND (2) #4 GND/IG 15BRKRP PANEL i ALUMINUM IN 2" C. L1U EDC1---------- ---- ------ C12 L ,7'4- ---� __REF 3-E3 L------- - - - UNDERGROUND UNDERGROUND UNDERGROUND UND RGROUND gOX INDICATES ITEMS THAT ARE --�------- 1 1 1 B20 15,340 LOCATED IN EDC TYP 68 8,726 3„ A17 14,111 619 17,09 NOTE: FEEDERS FROM EDC1 SHALL i 2„ i 12_1/2" 3,. I I PANEL BE UNDERGROUND AS NOTED H413 UNDERGROUND CONDUIT SIZE SHOWN UH3 I ( PANEL PANEL i i BELOW FEEDER DESIGNATION IS BASED i i H2A H26 I I ON SCHEDULE 40 PVC ________� I ----------------- l I I 1 Al2 115,009 1 r------ 1 1 � B3 12,33 12,700 I A8 AS 8,379 1 1 611 i 16,692 A14 116,689 I i 4840V i T2B T3D PANEL TFS �150 KVA 1 1 1 1 H4C 480V'%208Y/120V 480V 480V I I 1 1�r� ]ANEL I 225 KVA #2 CU 1 75 KVA #1/0 CU 1�`�-----------------------� 6 CU45 KVA I I#2/0 CU 1208Y 120V I` - C12 # GND 1 208Y/120V GND i20BY/120V 1 GND I / GND I ; �_____ _-- B12 C12 I �B6 i C9 I I I C20 1 1 I 1 B6 i 1 i I I 225A -3p PANEL BKR 2 -SECT. PANEL PANEL PANEL PANEL PANEL PANEL 1 i I L4D1 L4D2 L4D4 i L3D � 1 L2D1 L2D2 L26 L2P � I 1 I LJ _i i ' L._ 1 1 REF SUBWAY 1 1 1 1 B11 i� 612 DWGS L-------- 3 B9 I EDC4/POWERWALL ----i--------------------- EDC3 CONSOLE --_—`j EDC2—-----C9 --_—_ —JJJ 8 KVA Up S C3 C6 C3 C6 C6 C6 C61\ #8 CU GND PANELI PANEL PANEL PANEL PANEL PANEL PANEL PANEL T !PANEL! 1 L2U LVC LHC LRX LGC LTS1 LTS2 LTS3 i LSW r i (VISION (HAIR (PHARMACY)(GARDEN (TENANT) (TENANT) (TENANT) EQUIPMENT i (SUBWAY) } MROOM CENTER) CARE) CENTER) REF 3-E3 PARENTHESIS INDICATE LOCATION TYP LPL (PHOTO LAB) ONE -U. NTS Ui � W~Z WO LLZ� W � �irrcb�g�oa��viac�c, mq W 1'KW adz �ac�i�q�-'�N�a 2 W00Q<t:IqOQ,_-Lj o 'i UZUVr 1'4WjWW`�UU02 b OWE] w�W�a�c�a a�zzq MAIN SERVICE (MSB) - 3000 AMP BUS - A ,.Amr 39,196 'WF.O W cnwaya�g gSHU;NTTRIP Al1 NOTE: ALL FIRE PUMP ST GRADE WITHIN GRC OR IMC. CONDUIT ABOVE ROOM SHALL BE PUMP CONTROLLERS ARE PART OF A PREFABRICATED PUMP PACKAGE i i 1 TO PANEL HIB i i i 1 I I j � I � FIRE r1pou CKEY 31,466 PUMP 2,606 MPTRL FIRE PUMP, TRL JOCKEY PUMP, 1 1 #4 Cu GROUNDING 100 HP, 2 HP, ELECTRODE 480/3 480/3 CONDUCTOR. = 2 i --------------------------' i 1 i GROUND FIRE PUMP 1 II SERVICE SIMILAR TO 1 r--------------' DETAIL 2-E4 I � 1 A20 I 7,838 622 8,694 1 i I 1 I FIRE PUMP ROOM (2) #4 AND (1) #8 GND i `---------------------------- i PANEL PANEL COPPER IN 1" C. OR H1A H16 (2) #2 AND (1) #6 GND 1 UNDERGROUND 1 ALUMINUM IN 1" C. _________�----------- ---r--- �_il ---------- i ------------------------------------- 11 1 NOTE: DASHED LINE INDICATES FACTORY WIRING TYP 1 i B11 34,900 B11 i 6,699 1 I �7,68%� A8134,071 \/ I PANEL PANEL i TPL �N TlD 480V H1 P1 H1P2 A19 14,157 A38 13,575 480V ----- I 3" #8 CU i 25 KVA #2 CU I� 75 KVA PROVIDE EXOTHERMIC 1 ` 208Y/120V i GND 1 240/120V GND _____ - I MAIN MAIN WELD TO NEAREST _ is - i — AVAILABLE BUILDING UPSPANEL PANEL 1STEEL PER NEC, TYP i C12 i 8 KVA (COMPRESSOR (COMPRESSOR #8 CU(3) #1/0 AND (2) #6 GND/IG i GNDHOUSE #1) HOUSE #2) COPPER IN 1-1/2" C. i P2NSECT.EL OR D(3) #3/0 AND (2) #4 GND/IG 15BRKRP PANEL i ALUMINUM IN 2" C. L1U EDC1---------- ---- ------ C12 L ,7'4- ---� __REF 3-E3 L------- - - - UNDERGROUND UNDERGROUND UNDERGROUND UND RGROUND gOX INDICATES ITEMS THAT ARE --�------- 1 1 1 B20 15,340 LOCATED IN EDC TYP 68 8,726 3„ A17 14,111 619 17,09 NOTE: FEEDERS FROM EDC1 SHALL i 2„ i 12_1/2" 3,. I I PANEL BE UNDERGROUND AS NOTED H413 UNDERGROUND CONDUIT SIZE SHOWN UH3 I ( PANEL PANEL i i BELOW FEEDER DESIGNATION IS BASED i i H2A H26 I I ON SCHEDULE 40 PVC ________� I ----------------- l I I 1 Al2 115,009 1 r------ 1 1 � B3 12,33 12,700 I A8 AS 8,379 1 1 611 i 16,692 A14 116,689 I i 4840V i T2B T3D PANEL TFS �150 KVA 1 1 1 1 H4C 480V'%208Y/120V 480V 480V I I 1 1�r� ]ANEL I 225 KVA #2 CU 1 75 KVA #1/0 CU 1�`�-----------------------� 6 CU45 KVA I I#2/0 CU 1208Y 120V I` - C12 # GND 1 208Y/120V GND i20BY/120V 1 GND I / GND I ; �_____ _-- B12 C12 I �B6 i C9 I I I C20 1 1 I 1 B6 i 1 i I I 225A -3p PANEL BKR 2 -SECT. PANEL PANEL PANEL PANEL PANEL PANEL 1 i I L4D1 L4D2 L4D4 i L3D � 1 L2D1 L2D2 L26 L2P � I 1 I LJ _i i ' L._ 1 1 REF SUBWAY 1 1 1 1 B11 i� 612 DWGS L-------- 3 B9 I EDC4/POWERWALL ----i--------------------- EDC3 CONSOLE --_—`j EDC2—-----C9 --_—_ —JJJ 8 KVA Up S C3 C6 C3 C6 C6 C6 C61\ #8 CU GND PANELI PANEL PANEL PANEL PANEL PANEL PANEL PANEL T !PANEL! 1 L2U LVC LHC LRX LGC LTS1 LTS2 LTS3 i LSW r i (VISION (HAIR (PHARMACY)(GARDEN (TENANT) (TENANT) (TENANT) EQUIPMENT i (SUBWAY) } MROOM CENTER) CARE) CENTER) REF 3-E3 PARENTHESIS INDICATE LOCATION TYP LPL (PHOTO LAB) ONE -U. NTS Ui � W~Z WO LLZ� W � �irrcb�g�oa��viac�c, mq W 1'KW adz �ac�i�q�-'�N�a 2 W00Q<t:IqOQ,_-Lj o 'i UZUVr 1'4WjWW`�UU02 b OWE] w�W�a�c�a a�zzq zy) w w 00 � O" SHUNT TRIP 'WF.O W cnwaya�g gSHU;NTTRIP Al1 G ST C�'^'x�Az OA -3P MAIN L-0 3000A -3P MAIN D QC" BREAKER BREAKER w ZN� KIRK KEY Wim mmW X Q INTERLOCK, v Lu TYP r�r+, OI-- ULZj (SEE SCHEDULE KWH SHEET E4.1 SECTION 1 SECTION 2 SECTION 3 1 PUMP CONTROLLERS ARE PART OF A PREFABRICATED PUMP PACKAGE i i 1 TO PANEL HIB i i i 1 I I j � I � FIRE r1pou CKEY 31,466 PUMP 2,606 MPTRL FIRE PUMP, TRL JOCKEY PUMP, 1 1 #4 Cu GROUNDING 100 HP, 2 HP, ELECTRODE 480/3 480/3 CONDUCTOR. = 2 i --------------------------' i 1 i GROUND FIRE PUMP 1 II SERVICE SIMILAR TO 1 r--------------' DETAIL 2-E4 I � 1 A20 I 7,838 622 8,694 1 i I 1 I FIRE PUMP ROOM (2) #4 AND (1) #8 GND i `---------------------------- i PANEL PANEL COPPER IN 1" C. OR H1A H16 (2) #2 AND (1) #6 GND 1 UNDERGROUND 1 ALUMINUM IN 1" C. _________�----------- ---r--- �_il ---------- i ------------------------------------- 11 1 NOTE: DASHED LINE INDICATES FACTORY WIRING TYP 1 i B11 34,900 B11 i 6,699 1 I �7,68%� A8134,071 \/ I PANEL PANEL i TPL �N TlD 480V H1 P1 H1P2 A19 14,157 A38 13,575 480V ----- I 3" #8 CU i 25 KVA #2 CU I� 75 KVA PROVIDE EXOTHERMIC 1 ` 208Y/120V i GND 1 240/120V GND _____ - I MAIN MAIN WELD TO NEAREST _ is - i — AVAILABLE BUILDING UPSPANEL PANEL 1STEEL PER NEC, TYP i C12 i 8 KVA (COMPRESSOR (COMPRESSOR #8 CU(3) #1/0 AND (2) #6 GND/IG i GNDHOUSE #1) HOUSE #2) COPPER IN 1-1/2" C. i P2NSECT.EL OR D(3) #3/0 AND (2) #4 GND/IG 15BRKRP PANEL i ALUMINUM IN 2" C. L1U EDC1---------- ---- ------ C12 L ,7'4- ---� __REF 3-E3 L------- - - - UNDERGROUND UNDERGROUND UNDERGROUND UND RGROUND gOX INDICATES ITEMS THAT ARE --�------- 1 1 1 B20 15,340 LOCATED IN EDC TYP 68 8,726 3„ A17 14,111 619 17,09 NOTE: FEEDERS FROM EDC1 SHALL i 2„ i 12_1/2" 3,. I I PANEL BE UNDERGROUND AS NOTED H413 UNDERGROUND CONDUIT SIZE SHOWN UH3 I ( PANEL PANEL i i BELOW FEEDER DESIGNATION IS BASED i i H2A H26 I I ON SCHEDULE 40 PVC ________� I ----------------- l I I 1 Al2 115,009 1 r------ 1 1 � B3 12,33 12,700 I A8 AS 8,379 1 1 611 i 16,692 A14 116,689 I i 4840V i T2B T3D PANEL TFS �150 KVA 1 1 1 1 H4C 480V'%208Y/120V 480V 480V I I 1 1�r� ]ANEL I 225 KVA #2 CU 1 75 KVA #1/0 CU 1�`�-----------------------� 6 CU45 KVA I I#2/0 CU 1208Y 120V I` - C12 # GND 1 208Y/120V GND i20BY/120V 1 GND I / GND I ; �_____ _-- B12 C12 I �B6 i C9 I I I C20 1 1 I 1 B6 i 1 i I I 225A -3p PANEL BKR 2 -SECT. PANEL PANEL PANEL PANEL PANEL PANEL 1 i I L4D1 L4D2 L4D4 i L3D � 1 L2D1 L2D2 L26 L2P � I 1 I LJ _i i ' L._ 1 1 REF SUBWAY 1 1 1 1 B11 i� 612 DWGS L-------- 3 B9 I EDC4/POWERWALL ----i--------------------- EDC3 CONSOLE --_—`j EDC2—-----C9 --_—_ —JJJ 8 KVA Up S C3 C6 C3 C6 C6 C6 C61\ #8 CU GND PANELI PANEL PANEL PANEL PANEL PANEL PANEL PANEL T !PANEL! 1 L2U LVC LHC LRX LGC LTS1 LTS2 LTS3 i LSW r i (VISION (HAIR (PHARMACY)(GARDEN (TENANT) (TENANT) (TENANT) EQUIPMENT i (SUBWAY) } MROOM CENTER) CARE) CENTER) REF 3-E3 PARENTHESIS INDICATE LOCATION TYP LPL (PHOTO LAB) ONE -U. NTS Ui � W~Z WO LLZ� W � �irrcb�g�oa��viac�c, mq W 1'KW adz �ac�i�q�-'�N�a 2 W00Q<t:IqOQ,_-Lj o 'i UZUVr 1'4WjWW`�UU02 b OWE] w�W�a�c�a a�zzq 1-41 zy) w w 00 � O" C4 'WF.O W cnwaya�g iiz Mso„gymw E,3wzmo.- z C�'^'x�Az < zzOZXJ�= D ww zU�z�� = ¢0or w ZN� z Wim mmW X Q 3 v Lu 1-41 CHECKED BY. DRAWN BY. FILE NAME: E4 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11 /04 wr O U w w 00 � C4 Ua Cli WW d Z JLL ” O CV CO F o = ¢0or O a 02 g 0c z Lu z r�r+, OI-- ULZj ~<I_C5o u-w9,ww FaQJz a3 CHECKED BY. DRAWN BY. FILE NAME: E4 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11 /04 wr O U w w 00 � >-V) O g U Ua Cli WW d Z JLL N J = ¢0or 02 g 0c z z � m J ULZj ~<I_C5o u-w9,ww FaQJz cw�¢oz2 i r3NNoz ¢ iR hjwwLi �'' 1-- WaaO¢? z ONE -LINE DIAGRAM, DETA,LS AND SCHEDULES SHEET: L4�] LKVA KVA I 480V, 3 PH, 3W SERVES: HVAC 600A, M. L. 0. LOCATION: EDC1 (7) AIC, FULLY RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PLBRKR RKR WIRE DESCRIPTION PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 1 RTU1 #8 40 A B 7.15 13.75 3 60 #4 RTU2 (6) 2 PANELBOARD NOTES ( ) RTU18 #6 60 3 13.52 13.52 3 60 #4 RTU19 (6) 2 3 20 TON 20 20 22.67 21.90 13.52 13.52 1 SURFACE MOUNT 20 TON 7 3 RTU3 #8 40 3 13.52 13.52 3 20 #12 RTU4 (1) TERMINATE GROUND ON ISOLATED GROUND BUS. 3 RTU20 (6) #4 60 3 13.52 13.52 3 60 #6 RTU 21 4 C 20 TON 2 20 22.67 32.58 13.52 13.52 1 1 PANEL H2P (9) 20 TON 13 5 RTU5 #12 20 3 13.52 13.52 3 20 #12 (2) INSTALL LOCKING DEVICE FURNISHED WITH 6 5 RTU22 #8 40 3 7.04 3.63 3 20 #10 RTU23 (6) 6 15 10 TON 5 20 5.00 28.38 7.04 3.63 1 20 26.62 5 TON 19 7 RTU7 #12 20 3 7.04 3.63 3 15 PANELBOARD (LOCK -OFF FOR MAINTENANCE). RTU8 8 7 RTU24 #6 60 3 13.52 7.04 3 40 #8 RTU25 8 21 20 TON 71.78 3.88 13.52 7.04 1 20 SPACE 10 TON 25 9 #10 #12 15 3 13.52 7.04 3 (3) INSTALL LOCKING DEVICE FURNISHED WITH #12 RTU10 10 9 RTU26 #6 60 3 13.52 7.04 3 40 #8 RTU27 10 3 20 TON //6 AIR CURTAIN HEAT (2) 3.88 0.94 13.52 7.04 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 10 TON 31 11 RTU11 #12 15 3 13.52 7.04 PANELBOARD (LOCK -ON FOR CRITICAL LOAD). 15 #12 RTU12 12 11 RTU28 #12 20 3 3.63 3.63 3 20 #12 RTU29 12 18 5 TON AIR CURTAIN HEAT 2 3.88 3.63 3.63 3.60 5.00 1 20 5 TON 37 13 RTU13 #8 40 3 (4) GFI BREAKER. PANEL H2B 8 RTU14 480/3 13 RTU30 #12 15 96.75 137.29 2.55 3.63 3 20 #12 480/277/3 14 2 3 TON 3.60 5.00 3.88 2.55 3.63 96.75 127.25 5 TON TOTAL 15 RTU15 #12 TOTAL (5) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. 1013.00 970.87 KVA #6 RTU16 16 PER NEC ARTICLE 220 RTU32 3,708 3,657 3,505 AMPS 3 20 #12 RTU33 TOTAL LOAD AMPS 3 TON 28.8 KW, 480/3 FEEDER LOAD 142.30 3011.03 KVA 3,622 FEEDER LOAD 2465.66 KVA 2,966 AMPS RTU17 #6 (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR 3 2.55 3.63 30 SPACE 18 17 RTU34 #12 15 3 2.55 2.55 3 15 #12 RTU35 18 AMPS 3 TON 2.55 2.55 AMPS 3 TON 402.27 TOTAL 96.75 VOLTAGE DROP. SIZE EQUIPMENT GROUNDING 96.75 KVA 2.55 2.55 349 349 PER NEC ARTICLE 220 AMPS TOTAL LOAD 19 RTU36 #8 40 3 7.04 7.04 3 40 #8 RTU37 20 10 TON 7.04 7.04 10 TON CONDUCTOR PROPORTIONALLY PER NEC. 7.04 7.04 21 RTU38 #8 40 3 7.04 SPACE 22 10 TON 7.04 (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE 7.04 TOTAL 151.73 151.73 151.73 KVA 548 548 548 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 455.18 KVA 548 459.38 553 FAULT CURRENT FOR INTERRUPTING RATINGS. KVA AMPS (8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. (9) FACTORY WIRED TO LOAD. (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. KVA (11) THRU CONTACTOR. (12) REFER TO SUBWAY SHEETS. (X) DESIGNATES "SMART" BREAKER.KVA MSB MAIN SWITCHBOARD SECTION 3 SERVES: 480 VOLT DISTRIBUTION LOCATION: EDC1 PANEL PROVIDED WITH EDC DESCRIPTION WIRE BRKRPL PLBRKR WIRE DESCRIPTION 1 PANEL H3B (8) 125 3 28.32 3 15 #12 PLM 480/277/3 23.58 23.04 2 COMPRESSOR HOUSE 1 (8) 500 3 130.25 112.24 3 450 (8) COMPRESSOR HOUSE 2 3 480/3 130.25 112.24 480/3 130.25 112.24 4 PANEL H1B (8) 800 3 185.49 DEDICATED SPACE 480/277/3 179.98 149.66 5 PANEL H4B (8) 600 3 184.66 151.73 3 600 (8) PANEL H1A 6 480/277/3 181.18 151.73 480/3 179.96 151.73 7 PANEL H2A (8) 400 3 96.75 137.72 3 500 (8) 3 3 KVA LD H1 A PANELBOARD 480V, 3 PH, 3W SERVES: HVAC 600A, M. L. 0. LOCATION: EDC1 (7) AIC, FULLY RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PLBRKR RKR WIRE DESCRIPTION PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 1 RTU1 #8 40 A B 7.15 13.75 3 60 #4 RTU2 (6) 2 1 RTU18 #6 60 3 13.52 13.52 3 60 #4 RTU19 (6) 2 3 20 TON 20 20 22.67 21.90 13.52 13.52 1 SURFACE MOUNT 20 TON 7 3 RTU3 #8 40 3 13.52 13.52 3 20 #12 RTU4 4 3 RTU20 (6) #4 60 3 13.52 13.52 3 60 #6 RTU 21 4 C 20 TON 2 20 22.67 32.58 13.52 13.52 1 1 PANEL H2P (9) 20 TON 13 5 RTU5 #12 20 3 13.52 13.52 3 20 #12 RTU6 6 5 RTU22 #8 40 3 7.04 3.63 3 20 #10 RTU23 (6) 6 15 10 TON 5 20 5.00 28.38 7.04 3.63 1 20 26.62 5 TON 19 7 RTU7 #12 20 3 7.04 3.63 3 15 #12 RTU8 8 7 RTU24 #6 60 3 13.52 7.04 3 40 #8 RTU25 8 21 20 TON 71.78 3.88 13.52 7.04 1 20 SPACE 10 TON 25 9 #10 #12 15 3 13.52 7.04 3 15 #12 RTU10 10 9 RTU26 #6 60 3 13.52 7.04 3 40 #8 RTU27 10 3 20 TON //6 AIR CURTAIN HEAT (2) 3.88 0.94 13.52 7.04 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 10 TON 31 11 RTU11 #12 15 3 13.52 7.04 3 15 #12 RTU12 12 11 RTU28 #12 20 3 3.63 3.63 3 20 #12 RTU29 12 18 5 TON AIR CURTAIN HEAT 2 3.88 3.63 3.63 3.60 5.00 1 20 5 TON 37 13 RTU13 #8 40 3 3.63 3.63 PANEL H2B 8 RTU14 480/3 13 RTU30 #12 15 96.75 137.29 2.55 3.63 3 20 #12 480/277/3 14 2 3 TON 3.60 5.00 3.88 2.55 3.63 96.75 127.25 5 TON TOTAL 15 RTU15 #12 TOTAL 1027.16 1013.00 970.87 KVA #6 RTU16 16 PER NEC ARTICLE 220 RTU32 3,708 3,657 3,505 AMPS 3 20 #12 RTU33 TOTAL LOAD AMPS 3 TON 28.8 KW, 480/3 FEEDER LOAD 142.30 3011.03 KVA 3,622 FEEDER LOAD 2465.66 KVA 2,966 AMPS RTU17 #6 60 3 2.55 3.63 H1 A PANELBOARD 480V, 3 PH, 3W SERVES: HVAC 600A, M. L. 0. LOCATION: EDC1 (7) AIC, FULLY RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PLBRKR RKR WIRE DESCRIPTION PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 1 RTU1 #8 40 A B 7.15 13.75 3 60 #4 RTU2 (6) 2 1 RTU18 #6 60 3 13.52 13.52 3 60 #4 RTU19 (6) 2 3 20 TON 20 20 22.67 21.90 13.52 13.52 1 SURFACE MOUNT 20 TON 7 3 RTU3 #8 40 3 13.52 13.52 3 20 #12 RTU4 4 3 RTU20 (6) #4 60 3 13.52 13.52 3 60 #6 RTU 21 4 C 20 TON 2 20 22.67 32.58 13.52 13.52 1 1 PANEL H2P (9) 20 TON 13 5 RTU5 #12 20 3 13.52 13.52 3 20 #12 RTU6 6 5 RTU22 #8 40 3 7.04 3.63 3 20 #10 RTU23 (6) 6 15 10 TON 5 20 5.00 28.38 7.04 3.63 1 20 26.62 5 TON 19 7 RTU7 #12 20 3 7.04 3.63 3 15 #12 RTU8 8 7 RTU24 #6 60 3 13.52 7.04 3 40 #8 RTU25 8 21 20 TON 71.78 3.88 13.52 7.04 1 20 SPACE 10 TON 25 9 #10 #12 15 3 13.52 7.04 3 15 #12 RTU10 10 9 RTU26 #6 60 3 13.52 7.04 3 40 #8 RTU27 10 3 20 TON //6 AIR CURTAIN HEAT (2) 3.88 0.94 13.52 7.04 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 10 TON 31 11 RTU11 #12 15 3 13.52 7.04 3 15 #12 RTU12 12 11 RTU28 #12 20 3 3.63 3.63 3 20 #12 RTU29 12 18 5 TON AIR CURTAIN HEAT 2 3.88 3.63 3.63 3.60 5.00 1 20 5 TON 37 13 RTU13 #8 40 3 3.63 3.63 3 15 #12 RTU14 14 13 RTU30 #12 15 3 2.55 3.63 3 20 #12 RTU31 14 2 3 TON 3.60 5.00 3.88 2.55 3.63 5 TON TOTAL 15 RTU15 #12 20 3 2.55 3.63 3 60 #6 RTU16 16 15 RTU32 #12 15 3 2.55 3.63 3 20 #12 RTU33 16 KVA 3 TON 28.8 KW, 480/3 FEEDER LOAD 142.30 28 2.55 3.63 SPACE 5 TON 17 RTU17 #6 60 3 2.55 3.63 30 SPACE 18 17 RTU34 #12 15 3 2.55 2.55 3 15 #12 RTU35 18 AMPS 3 TON 2.55 2.55 AMPS 3 TON 402.27 TOTAL 96.75 96.75 96.75 KVA 2.55 2.55 349 349 PER NEC ARTICLE 220 AMPS TOTAL LOAD 19 RTU36 #8 40 3 7.04 7.04 3 40 #8 RTU37 20 10 TON 7.04 7.04 10 TON 7.04 7.04 21 RTU38 #8 40 3 7.04 SPACE 22 10 TON 7.04 7.04 TOTAL 151.73 151.73 151.73 KVA 548 548 548 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 455.18 KVA 548 459.38 553 FEEDER LOAD KVA AMPS H2A PANELBOARD 480V, 3 PH, 3W SERVES: HVAC 400A, M. L. 0. LOCATION: EDC2 (7) AIC, FULLY RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PL RKR WIRE DESCRIPTION PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 1 RTU1 #8 40 3 7.15 13.75 3 60 #4 RTU2 (6) 2 480/3 10 TON RATED PANEL PROVIDED WITH EDC 22.67 21.10 7.15 13.75 1 20 75 KVA, 480/3 20 TON 5 3 SALES FLOOR LIGHTING (X) 20 20 22.67 21.90 7.15 13.75 1 SURFACE MOUNT 6 7 3 RTU3 #8 40 3 7.15 3.69 3 20 #12 RTU4 4 480/3 10 TON 20 20 22.67 39.35 7.15 3.69 1 20 480/277/3 5 TON 11 C SALES FLOOR LIGHTING (X) 2 20 22.67 32.58 7.15 3.69 1 1 PANEL H2P (9) 12 13 5 RTU5 #12 20 3 3.69 3.69 3 20 #12 RTU6 6 15 KW, 480/3 5 TON 20 5.00 36.60 3.69 3.69 1 20 480/277/3 5 TON 17 15 4 5 20 5.00 28.38 3.69 3.69 1 20 26.62 18 19 7 RTU7 #12 20 3 3.69 2.61 3 15 #12 RTU8 8 10 HP, 480/3 5 TON 20 20 3.88 16.14 3.69 2.61 1 8 5 8 1 3 TON 23 21 SALES FLOOR LIGHTING (X) 71.78 3.88 3.69 2.61 1 20 SPACE 24 25 9 #10 #12 15 3 2.61 2.61 3 15 #12 RTU10 10 10 HP, 480/3 JRTU9 3 TON 12 13 3.88 0.94 2.61 2.61 50 3 2 HP, 480/3 3 TON 29 3 50 //6 AIR CURTAIN HEAT (2) 3.88 0.94 2.61 2.61 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 30 31 11 RTU11 #12 15 3 2.61 2.61 3 15 #12 RTU12 12 10 HP, 480/3 3 TON SALES FLOOR LIGHTING (6,X) #8 3.88 2.61 2.61 2.68 1.59 1 28.6 KW, 480/3 3 TON 35 18 19 AIR CURTAIN HEAT 2 3.88 2.61 2.61 3.60 5.00 1 20 36 37 13 RTU13 #8 40 3 7.15 2.61 3 15 #12 RTU14 14 10, HP 480/3 10 TON 20 2 3.88 7.15 2.61 22 23 AIR CURTAIN HEAT 3 TON 41 2 39 3.60 5.00 3.88 7.15 2.61 42 TOTAL 15 RTU15 #12 20 3 3.69 13.75 3 60 #6 RTU16 16 515.14 5 TON 620 557.79 671 3.69 13.75 KVA AMPS 9.60 20 TON AMPS KVA 137 28.8 KW, 480/3 FEEDER LOAD 142.30 28 3.69 13.75 SPACE 17 RTU17 #6 60 3 13.75 30 SPACE 18 137.29 20 TON KVA 13.75 497 496 459 PER NEC ARTICLE 220 AMPS 13.75 AMPS 402.27 TOTAL 96.75 96.75 96.75 KVA 349 349 349 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 290.24 KVA 349 294.43 354 FEEDER LOAD KVA AMPS H1 B PANELBOARD 480/277V, 3 PH, 4W SERVES: 480 VOLT DISTRIBUTION 800A, M. L. 0. LOCATION: EDC1 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE RKRPL PL O'-'xY��z PLBRKR zc�owxwQ= WIRE DESCRIPTION PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 AHU2 #2 110 3 22.67 25.55 3 125 (8) TRANSFORMER T1D (9) 2 3 480/3 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC 22.67 21.10 3.87 1.58 1 20 75 KVA, 480/3 4 5 3 SALES FLOOR LIGHTING (X) 20 20 22.67 21.90 3.87 1.37 1 SURFACE MOUNT 6 7 AHU3 #2 110 3 22.67 41.91 3 200 (8) PANEL H1 P1 (9) 8 9 480/3 SALES FLOOR LIGHTING (X) 20 20 22.67 39.35 3.87 3.53 1 20 480/277/3 10 11 C SALES FLOOR LIGHTING (X) 2 20 22.67 32.58 3.87 3.42 1 1 PANEL H2P (9) 12 13 WH -GR RECEIVING (2) #10 30 3 5.00 33.94 3 200 (8) PANEL H1P2 (9) 14 15 15 KW, 480/3 SALES FLOOR LIGHTING (X) 20 5.00 36.60 28.18 1 20 480/277/3 16 17 15 4 5 20 5.00 28.38 3.87 2.51 1 20 26.62 18 19 BALER #10 30 3 3.88 17.29 2 70 (8) TRANSFORMER TPL (9) 20 21 10 HP, 480/3 SALES FLOOR LIGHTING (X) 20 20 3.88 16.14 DEDICATED SPACE 1 8 5 8 1 2 23 21 SALES FLOOR LIGHTING (X) 71.78 3.88 3.87 4.02 1 20 SPACE 24 25 BALER #10 30 3 3.88 0.94 3 2 #6 0 P 3 2 27 10 HP, 480/3 25 12 13 3.88 0.94 #6 50 3 2 HP, 480/3 28 29 3 50 //6 AIR CURTAIN HEAT (2) 3.88 0.94 14 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 30 31 COMPACTOR #10 30 3 3.88 3 28.8 KW, 480/3 #6 SPACE 32 33 10 HP, 480/3 31 SALES FLOOR LIGHTING (6,X) #8 3.88 9.60 2.68 1.59 1 28.6 KW, 480/3 34 35 18 19 AIR CURTAIN HEAT 2 3.88 2 3.60 5.00 1 20 36 37 COMPACTOR #10 30 3 3.88 7.2 KW, 480/1 50 #6 SPACE 38 39 10, HP 480/3 37 20 2 3.88 1 22 23 AIR CURTAIN HEAT 40 41 2 39 3.60 5.00 3.88 1 42 TOTAL 185.49 179.98 149.66 KVA 670 650 540 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 515.14 KVA 620 557.79 671 FEEDER LOAD KVA AMPS 9.60 TOTAL LOAD 113.84 H2B 480/277V, 3 PH, 4W PANELBOARD LOCATION: EDC4 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PLBRKR zc�owxwQ= WIRE 480/277V, 3 PH, 4W SERVES: 480 VOLT DISTRIBUTION o 1 TRANSFORMER T4D (9) (8) 225 3 600A, M. L. 0. LOCATION: EDC2 60 (8) PANEL H4C (9) 2 3 150 KVA, 480/3 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC 42.39 2.18 3.87 1.58 1 20 480/277/3 4 GROUND BUS 3 SALES FLOOR LIGHTING (X) 20 20 39.51 3.64 3.87 1.37 1 SURFACE MOUNT 6 DESCRIPTION WIRE BRKRPL 125 3 15.00 10.28 3 PL RK WIRE DESCRIPTION 9 75 KVA, 480/3 SALES FLOOR LIGHTING (X) 20 20 19.32 10.28 3.87 3.53 1 20 A B 11 C SALES FLOOR LIGHTING (X) 2 20 15.91 10.28 3.87 3.42 1 1 PANEL H2P (9) (8) 200 3 26.78 110 3 22.67 9.70 3 45 DEDICATED SPACE 056 FRYER W/BSKT LIFT (2) 2 3 480/277/3 SALES FLOOR LIGHTING (X) 20 22.67 9.70 28.18 1 20 35.0 A, 480/3 16 17 15 4 5 20 22.67 9.70 3.87 2.51 1 20 26.62 18 19 AIR CURTAIN HEAT (2) #6 50.3 20 6 7 TRANSFORMER T2B (9) (8) 30013, 20 70.01 28.8 KW, 480/3 SALES FLOOR LIGHTING (X) 20 20 9.60 12.19 DEDICATED SPACE 1 8 9 225 KVA, 480/3 23 21 SALES FLOOR LIGHTING (X) 71.78 9.60 12.19 3.87 4.02 1 20 SHUNT -TRIP BREAKER 24 10 11 #3 90 3 17.93 12.19 3 63.30 #6 058 FRYER (2) 26 27 64.7A, 480/3 25 12 13 AIR CURTAIN HEAT #6 50 3 9.53 9.60 28 29 3 50 //6 AIR CURTAIN HEAT (2) 17.93 12.19 14 15 28.6 KW, 480/3 SHUNT -TRIP BREAKER 30 31 SPACE 9.53 9.60 SALES FLOOR LIGHTING (X) 9.53 3 28.8 KW, 480/3 #6 16 17 33 SPACE 31 SALES FLOOR LIGHTING (6,X) #8 9.53 9.60 2.68 1.59 1 28.6 KW, 480/3 34 35 18 19 AIR CURTAIN HEAT 2 20 2 3.60 5.00 1 20 3 30 #10 WH -HAIR CARE (2) 20 20 21 7.2 KW, 480/1 50 #6 AIR CURTAIN HEAT (2) 38 3.60 5.00 AIR CURTAIN HEAT 37 20 2 15 KW, 480/3 1 22 23 AIR CURTAIN HEAT 40 20 2 39 3.60 5.00 3.60 9.60 ` 1 24 25 7.2 KW, 480/1 181.18 179.96 KVA 3.60 9.60 654 650 3 50 #6 AIR CURTAIN HEAT (2) 545.80 26 27 SPACE 456 FEEDER LOAD KVA AMPS 9.60 TOTAL LOAD 113.84 AMPS KVA 137 28.8 KW, 480/3 FEEDER LOAD 142.30 28 29 SPACE 9.60 30 TOTAL 137.72 137.29 127.25 KVA 497 496 459 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 402.27 KVA 484 FEEDER LOAD 408.36 KVA 491 AMPS H46 PANELBOARD 480/277V, 3 PH, 4W SERVES: GROCERY 480 VOLT EQUIPMENT 600A, M. L. 0. LOCATION: EDC4 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PL O'-'xY��z PLBRKR zc�owxwQ= WIRE DESCRIPTION SERVES: GROCERY LIGHTING uazV�Z~w Zw NJ o 1 TRANSFORMER T4D (9) (8) 225 3 45.11 7.25 3 60 (8) PANEL H4C (9) 2 3 150 KVA, 480/3 SALES FLOOR LIGHTING (X) >-Q m � > 20 42.39 2.18 3.87 1.58 1 20 480/277/3 4 5 3 SALES FLOOR LIGHTING (X) 20 20 39.51 3.64 3.87 1.37 1 20 GARDEN CENTER LTG 6,X 6 7 TRANSFORMER TFS (9,12) (8) 125 3 15.00 10.28 3 50 #6 B05 PAN WASHER (2) 8 9 75 KVA, 480/3 SALES FLOOR LIGHTING (X) 20 20 19.32 10.28 3.87 3.53 1 20 37.1 A, 480/3 10 11 9 SALES FLOOR LIGHTING (X) 2 20 15.91 10.28 3.87 3.42 1 20 #10 12 13 AHU1 �2 110 3 22.67 9.70 3 45 #8 056 FRYER W/BSKT LIFT (2) 14 15 480/3 SALES FLOOR LIGHTING (X) 20 22.67 9.70 3.87 2.45 1 20 35.0 A, 480/3 16 17 15 SALES FLOOR LIGHTING (X) 20 20 22.67 9.70 3.87 2.51 1 20 SHUNT -TRIP BREAKER 18 19 AIR CURTAIN HEAT (2) #6 50.3 20 9.60 12.19 3 60 #6 058 FRYER (2) 20 21 28.8 KW, 480/3 SALES FLOOR LIGHTING (X) 20 20 9.60 12.19 3.87 4.08 1 20 44.0 A, 480/3 22 23 21 SALES FLOOR LIGHTING (X) 20 9.60 12.19 3.87 4.02 1 20 SHUNT -TRIP BREAKER 24 25 B35E RACK OVEN (2) #3 90 3 17.93 12.19 3 60 #6 058 FRYER (2) 26 27 64.7A, 480/3 25 SALES FLOOR LIGHTING (X) 17.93 12.19 1 3.87 3.94 1 44.0 A, 480/3 28 29 26 27 SALES FLOOR LIGHTING (X) 20 17.93 12.19 1 3.87 1.97 1 SHUNT -TRIP BREAKER 30 31 SPACE 29 SALES FLOOR LIGHTING (X) 9.53 3 50 #6 AIR CURTAIN HEAT 32 33 SPACE 31 SALES FLOOR LIGHTING (6,X) #8 9.53 1 2.68 1.59 1 28.6 KW, 480/3 34 35 AIR CURTAIN HEAT 33 20 2 3.60 9.53 1 4.17 2.52 1 20 36 37 7.2 KW, 480/1 35 20 1 3.60 9.60 3 50 #6 AIR CURTAIN HEAT (2) 38 39 AIR CURTAIN HEAT 37 20 2 3.60 9.60 1 2.68 28.8 KW, 480/3 40 41 7.2 KW, 480 1 39 SPARE (X) 20 3.60 9.60 ` 1 42 TOTAL 184.66 181.18 179.96 KVA 667 654 650 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 545.80 KVA 657 378.70 456 FEEDER LOAD KVA AMPS AMPS TOTAL LOAD 113.84 H1 P1 POWER SWITCHING PANELBOARD 480/277V, 3 PH, 4W SERVES: LIGHTING 250A BUS WITH 2O0A PANEL -MOUNTED FUSES LOCATION: EDC1 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRK PL O'-'xY��z PLBRKR zc�owxwQ= WIRE DESCRIPTION SERVES: GROCERY LIGHTING uazV�Z~w Zw NJ o 1 1 SALES FLOOR 20 2 B 1 20 #10 GARDEN CENTER LTG (6,X) 2 3 1 SALES FLOOR LIGHTING (X) >-Q m � > 20 1 3.87 1.58 1 20 GARDEN CENTER LTG (6,X) EMERGENCY LIGHTING (3) 2 3 SALES FLOOR LIGHTING (X) 20 20 1 3.87 1.37 1 20 GARDEN CENTER LTG 6,X SECURITY LIGHTING (X) 4 5 SALES FLOOR LIGHTING (X 20 1 3.87 1.94 1 20 PERIMETER LIGHTING SECURITY LIGHTING (X) 6 7 SALES FLOOR LIGHTING (X) 20 20 1 3.87 3.53 1 20 #10 PERIMETER LIGHTING (6} 8 9 SALES FLOOR LIGHTING (X) 2 20 1 3.87 3.42 1 20 #10 PERIMETER LIGHTING (6) 10 11 SALES FLOOR LIGHTING (X) 20 20 1 3.87 3.42 1 20 #10 PERIMETER LIGHTING (6) 12 13 SALES FLOOR LIGHTING (X) 20 1 3.87 2.45 1 20 #10 PERIMETER LIGHTING (6) 14 15 SALES FLOOR LIGHTING (X) 20 20 1 3.87 2.51 1 20 #10 PERIMETER LIGHTING (6) 16 17 SALES FLOOR LIGHTING (X) SPARE 20 1 3.87 2.28 1 20 #10 PERIMETER LIGHTING (6) 18 19 SALES FLOOR LIGHTING (X) 20 20 1 3.87 4.08 1 20 #10 DOCK LIGHTING (6) 20 21 SALES FLOOR LIGHTING (X) 20 1 3.87 4.02 1 20 #10 STOCKROOM LIGHTING (6) 22 23 SALES FLOOR LIGHTING (X) (5) 20 1 3.87 2.59 1 20 LAYAWAY RESTROOM LTG 24 27 25 SALES FLOOR LIGHTING (X) 20 1 3.87 3.94 1 20 PHARM DRIVE-THRU LTG (6,X) STOCKROOM LTG (9) 26 27 SALES FLOOR LIGHTING (X) 20 20 1 3.87 1.97 1 20 PORTRAIT STUDIO X BREAKROOM/TRAINING LTG 28 29 SALES FLOOR LIGHTING (X) 20 1 3.87 1 20 SPARE SPARE' 30 31 SALES FLOOR LIGHTING (6,X) #8 20 1 2.68 1.59 1 20 SPARE (FUTURE BANK) (X) DAIRY COOLER/GR STOCKRM 32 33 SALES FLOOR LIGHTING (6,X) #8 20 1 4.17 2.52 1 20 #10 TIRE SHOWROOM LTG (6,X) 34 35 SALES FLOOR LIGHTING (6,X) 8 20 1 2.98 1 20 SPACE SPARE 36 37 SALES FLOOR LIGHTING (6,X) #8 20 1 2.68 SPACE SPACE 38 39 SPARE (X) 20 20 1 SPACE SPACE 40 41 SPACE 26.62 KVA 97 102 PER NEC ARTICLE 220 96 AMPS TOTAL LOAD 98 AMPS SPACE 42 TOTAL 41.91 39.35 32.58 KVA PER NEC ARTICLE 220 151 142 118 AMPS TOTAL LOAD 113.84 AMPS KVA 137 171 FEEDER LOAD 142.30 KVA AMPS H1 P2 POWER SWITCHING PANELBOARD 480/277V, 3 PH, 4W SERVES: LIGHTING 250A BUS WITH 2O0A PANEL -MOUNTED FUSES LOCATION: EDC1 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIREBRKRPL BRKRPL �-Aq�U1M�W Z O'-'xY��z PLBRKR zc�owxwQ= WIRE DESCRIPTION SERVES: GROCERY LIGHTING uazV�Z~w Zw NJ o 1 1 SALES FLOOR 20 2 3 3.87 1 20 #10 GARDEN CENTER LTG (6,X) 2 3 480/1 PANEL PROVIDED WITH EDC >-Q m � > � 1.13 1.74 r 1 20 #10 GARDEN CENTER LTG (6,X) 4 5 PARKING LOT LIGHTING X 5 20 2 2.82 2.45 1 20 10 GARDEN CENTER LTG 6,X 6 7 480/1 Baa z J PLBRKR 2.82 3.65 1 20 DESCRIPTION PERIMETER LIGHTING 8 9 PARKING LOT LIGHTING (X) (5) 20 2 3.38 3.53 1 20 a PERIMETER LIGHTING 10 111480/1 / GROC STOCKRM 2 3 3.38 3.53 1 20 1 PERIMETER LIGHTING 12 13 PARKING LOT LIGHTING (X) (5) 20 2 3.38 0.95 1 20 PRODUCE SPOT LIGHTING HAIR CARE LIGHTING (X) 14 15 480/1 3.64 3.38 1.72 1 20 VESTIBULE/LP OFFICE LTG 16 17 PARKING LOT LIGHTING X 5 20 2 2.26 2.81 1 20 VISION CENTER LIGHTING X 18 19 480/1 9 SPARE 2.26 1.35 1 20 PHARMACY LIGHTING (X) 20 21 PARKING LOT LIGHTING (X) (5) 20 2 2.26 3.52 1 20 COURTESY DESK /RESTROOM 22 23 480 1 2.26 0.18 1 20 13 FLAG POLE LIGHTING X 24 25 PARKING LOT LIGHTING (X) (5) 20 2 3.38 1.11 1 20 TENANT SPACE LIGHTING (X) 26 27 480/1 3.38 0.76 1 20 #10 PHARM DRIVE-THRU LTG (6,X) 28 29 PARKING LOT LIGHTING X 5 20 2 2.88 0.39 1 20 PORTRAIT STUDIO X 3D 31 480/1 SPACE 18 2.88 1 20 SPARE 32 33 PARKING SECURITY LTG (X) (5) 20 2 3.38 1 20 13 SPARE (FUTURE BANK) (X) 34 35 480 1 TOTAL LOAD 13.07 3.38 1 20 16 SPARE 36 37 SPACE 20 FEEDER LOAD KVA AMPS SPACE 38 39 SPACE SPACE 40 41 EMERGENCY LIGHTING 3 20 1 0.29 SPACE 42 TOTAL 26.78 28.18 26.62 KVA 97 102 PER NEC ARTICLE 220 96 AMPS TOTAL LOAD 98 AMPS 81.59 KVA FEEDER LOAD 101.98 KVA 123 AMPS H2P POWER SWITCHING PANELBOARD 480/277V, 3 PH, 4W SERVES: FRONT LIGHTING 250A BUS WITH 2O0A PANEL -MOUNTED FUSES LOCATION: EDC2 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL �-Aq�U1M�W Z O'-'xY��z PLBRKR zc�owxwQ= WIRE DESCRIPTION SERVES: GROCERY LIGHTING uazV�Z~w Zw NJ o 1 WAL-MART SIGN (2,X) (5) 20 2 3 3.87 1 20 #10 GARDEN CENTER LTG (6,X) 2 3 480/1 PANEL PROVIDED WITH EDC >-Q m � > � 1.13 1.74 r 1 20 #10 GARDEN CENTER LTG (6,X) 4 5 PARKING LOT LIGHTING X 5 20 2 2.82 2.45 1 20 10 GARDEN CENTER LTG 6,X 6 7 480/1 Baa z J PLBRKR 2.82 3.65 1 20 DESCRIPTION PERIMETER LIGHTING 8 9 PARKING LOT LIGHTING (X) (5) 20 2 3.38 3.53 1 20 a PERIMETER LIGHTING 10 111480/1 / GROC STOCKRM 2 3 3.38 3.53 1 20 1 PERIMETER LIGHTING 12 13 PARKING LOT LIGHTING (X) (5) 20 2 3.38 0.95 1 20 PRODUCE SPOT LIGHTING HAIR CARE LIGHTING (X) 14 15 480/1 3.64 3.38 1.72 1 20 VESTIBULE/LP OFFICE LTG 16 17 PARKING LOT LIGHTING X 5 20 2 2.26 2.81 1 20 VISION CENTER LIGHTING X 18 19 480/1 9 SPARE 2.26 1.35 1 20 PHARMACY LIGHTING (X) 20 21 PARKING LOT LIGHTING (X) (5) 20 2 2.26 3.52 1 20 COURTESY DESK /RESTROOM 22 23 480 1 2.26 0.18 1 20 13 FLAG POLE LIGHTING X 24 25 PARKING LOT LIGHTING (X) (5) 20 2 3.38 1.11 1 20 TENANT SPACE LIGHTING (X) 26 27 480/1 3.38 0.76 1 20 #10 PHARM DRIVE-THRU LTG (6,X) 28 29 PARKING LOT LIGHTING X 5 20 2 2.88 0.39 1 20 PORTRAIT STUDIO X 3D 31 480/1 SPACE 18 2.88 1 20 SPARE 32 33 PARKING SECURITY LTG (X) (5) 20 2 3.38 1 20 13 SPARE (FUTURE BANK) (X) 34 35 480 1 TOTAL LOAD 13.07 3.38 1 20 16 SPARE 36 37 SPACE 20 FEEDER LOAD KVA AMPS SPACE 38 39 SPACE SPACE 40 41 EMERGENCY LIGHTING 3 20 1 0.29 SPACE 42 TOTAL 26.78 28.18 26.62 KVA 97 102 PER NEC ARTICLE 220 96 AMPS TOTAL LOAD 98 AMPS 81.59 KVA FEEDER LOAD 101.98 KVA 123 AMPS H4C zcn a DRAWN BY: PANELBOARD FILE NAME: WN�wm �wF`=�ooz PROTO CYCLE: w^•,x mnnw w0o� cn wz E3 �-Aq�U1M�W Z O'-'xY��z U O zc�owxwQ= N Lfl 480/277V, 3 PH, 4W SERVES: GROCERY LIGHTING uazV�Z~w Zw NJ o O Lo =) J W Q 100A, M. L. 0. LOCATION: EDC4 C-3 W J Of dW¢w O f'1 E-� � (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC >-Q m � > � U - Q J GROUND BUS r�F- SURFACE MOUNT fro >-W 0:0z V 1 DESCRIPTION WIRE BRKRPL Baa z J PLBRKR mL11 WIRE DESCRIPTION MF -5:v) Z 1 BAKERY /DELI LIGHTING w�CL www of 20 1 2.99 1.66 a 1 20 SEAFOOD / GROC STOCKRM 2 3 PRODUCE LIGHTING 20 1 0.90 1.28 1 20 VESTIBULE LIGHTING 4 5 PRODUCE SPOT LIGHTING 20 1 3.64 SPACE 6 7 PRODUCE SPOT LIGHTING 20 1 2.60 SPACE 8 9 SPARE 20 1 SPACE 10 11 SPACE SPACE 12 13 SPACE SPACE 14 15 SPACE SPACE 16 17 SPACE SPACE 18 TOTAL 7.25 2.18 3.64 KVA 26 8 13 PER NEC ARTICLE 220 AMPS TOTAL LOAD 13.07 KVA 16 AMPS 16.34 20 FEEDER LOAD KVA AMPS � o W a oo� WZ � O O yaZZWO O 4 Z- � aaoOawcwiza w�' ¢ a ¢�woow W a zo ��c�4 ¢wz za Z alit/ Q�OOOVOWw WZ W OF=O O �w�wl-a �cwi�az z,¢ J ui,aOk'Fjawa = oottww�owow � NwF¢=Uam�� ISSUE BLOCK I /3\ 102/28/05C.C.D. #131 CHECKED BY: zcn a DRAWN BY: O��//Aein rn w FILE NAME: WN�wm �wF`=�ooz PROTO CYCLE: w^•,x mnnw w0o� cn wz E3 �-Aq�U1M�W Z O'-'xY��z U O zc�owxwQ= N Lfl F � uazV�Z~w Zw NJ o O Lo =) J W Q ISSUE BLOCK I /3\ 102/28/05C.C.D. #131 CHECKED BY: DRAWN BY: zW w 00 � FILE NAME: E4.1 PROTO CYCLE: 062504 rF} 08/11/04 U O o N Lfl F � N U Wo U_ d fnJ J W O Lo =) J W Q r� C-3 W J Of dW¢w O f'1 E-� � o w >-Q m � > � U - Q J ISSUE BLOCK I /3\ 102/28/05C.C.D. #131 CHECKED BY: DRAWN BY: zW w 00 � FILE NAME: E4.1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 xr O U zW w 00 � } o U O Ll W x � N U Wo U_ d fnJ J W O Lo =) J W Q aoo� _ lk J Of dW¢w O W to Z D w >-Q m � > � U - Q J r�F- fro >-W 0:0z V 1 wwzww Baa z J mL11 }�00U¢ZZ LL 0a MF -5:v) Z � w�CL www of =w?oa� :z a _�cndcna in o PANELBOARD SCHEDULES SHEET: E4, 1 I L1 D2 . GROUND EQUIPMENT SERVES: 208 VOLT DISTRIBUTION 10,000 AIC LOCATION: EDC2 GROUND BUS PANELBOARD SURFACE MOUNT PANELBOARD DESCRIPTION 240/120V, 1 PH, 3W 100A, M. L. 0. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT BRKRPL DESCRIPTION RKR WIRE RK PL DESCRIPTION DESCRIPTION PL RK 1 L RKR WIRE DESCRIPTION 11.81 A 208/120V, 3 PH, 4W SERVES: ELECTRONICS PANELBOARD NOTES ( ) 3 208/120/3 15 15 1 1 1 0.25 #6 0.36 2 100A, M. C. B. LOCATION: EDC1 20 20 PAY STATION P.A. /TELE. EQUIP. (9) EP/2 (9 2 4 12.89 0.25 0.05 5 7 UPC SYSTEM MODULE UPC SYSTEM MODULE 2.20 0.12 15 15 1 10.25 10,000 AIC PANEL PROVIDED WITH EDC 17.38 LAY -AWAY CASH WRAPS UP,C SYSTEM, MODULE (1) TERMINATE GROUND ON ISOLATED GROUND BUS. 1 DEDICATED SPACE 9 11 UPC SYSTEM MODULE UPC SYSTEM MODULE 208/120/3 15 15 GROUND BUS 0.25 1.80 15.29 2 30 #10 IBM BLADECENTER 3.6 KW, 208 1 10 12 11 0.25 1.80 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 9 SURFACE MOUNT KVA KVA 20 DESCRIPTION KVA AMPS AMPS AMPS ti M WIRE BRKRPL 24 29 (2) INSTALL LOCKING DEVICE FURNISHED WITH PL RK WIRE DESCRIPTION DEDICATED SPACE 14 15 1 ELECTRONICS (6) 13 9.23 #10 20 1 1.08. 1.44 16 1 20 #10 OUTRIGGER TV WALL (6) 2 3 ELECTRONICS (6) 0.50 0.96 18 #10 PANELBOARD (LOCK -OFF FOR MAINTENANCE). 1 0.92 1.44 3 1 20 #10 OUTRIGGER TV WALL (6) 4 5 ELECTRONICS 6 18 19 10 20 1 1 0.72 1.44 1 20 10 OUTRIGGER TV WALL 6 6 7 ELECTRONICS (6) 1 (3) INSTALL LOCKING DEVICE FURNISHED WITH #8 20 1 1.08 1.44 100 1 20 #8 OUTRIGGER TV WALL (6) 8 9 ELECTRONICS (6) DRY PIPE COMPRESSOR 2,6 24 #8 20 1 1.08 1.44 1 1 20 #8 OUTRIGGER 7V WALL (6) 10 11 ELECTRONICS PANELBOARD (LOCK -ON FOR CRITICAL LOAD). 6 1 8 20 1 PANEL LTS3 (1) 1.20 1.44 1 20 8 OUTRIGGER TV WALL 6 12 13 ELECTRONICS (HDTV) (6) HIRING KIOSK (1) #8 20 1 1.20 1.62 20 1 20 #10 OFFSET TV DISPLAY (6) 14 (4) GFI BREAKER. L1 D (HDTV) (6) PANELBOARD #8 20 1 208/12ov, 3 PH, 4W 1 20 #10 OFFSET TV DISPLAY (6) 16 17 ELECTRONICS HDTV 6 SPACE 8 20 1 11.96 1.20 1.62 1 20 10 (5) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. TWO -SECTION PANEL 18 19 SECTION #1: BREAKERS 1-42 10.35 #10 20 225A, M. C. B. 1 1.62 TOTAL 71.50 71.37 1 20 #8„ OFFSET TV DISPLAY (6) 20. 21 SPARE FEEDER LOAD 191.69 KVA 532 AMPS #6 20 1 TOTAL 11.81 13.09 12.89 KVA (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR WITH FEED-THRU LUGS TOTAL LOAD 37.80 SPARE SECTION #2: BREAKERS 43-84 23 SPARE KVA 10,000 AIC 1 20 1 AMPS (1) 50 51 SPACE SPARE 0.56 24 0.54 1 20 #10 SOFTLINES/DSD DESK (1,6) 52 53 VOLTAGE DROP. SIZE EQUIPMENT GROUNDING SERVES: GENERAL POWER KVA 1.66 0.36 1 20 PER NEC ARTICLE INVOICING RECEPTACLES 1 GROUND BUS (BOTH SECTIONS) 55 SPACE 23 23 79 64 64 1.26 1 20 AMPS TRAINING ROOM RECEPTS (1) 56 57 SPACE TOTAL LOAD 7.01 KVA 0.54 1 20 CONDUCTOR PROPORTIONALLY PER NEC. LOCATION: EDC1 58 59 SPACE 005 WRAPPER/D04A SCALE O#10 FEEDER LOAD ISOLATED GROUND BUS (SECT 2 ONLY) 1 20 • kiIRING„K)O.SK 60 61 SPACE DELI RECEPTACLES 20 0.54 1 20 #10 AUTO/WAX/PICS,(6) 62 63 SPACE 19.56 (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE PANEL PROVIDED WITH EDC 0.36 1 20 187 AMPS 64 65 SURFACE MOUNT 0.72 1 20 LPTVS PICS ELECTRONICS 66 67 SPACE 0.72 1 20 #1D TV'S/PICS/TOYS (6) FAULT CURRENT FOR INTERRUPTING RATINGS. DESCRIPTION WIRE RKRPL PLBRKR WIRE DESCRIPTION PICS/LPTV (6) 70 71 SPACE 1.08 1 20 6 JIB CRANE 6 KVA 73 SPACE (8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. 1.08 1 20 #10 AHU2, RTU'S 20,21,23-25 (6) 74 75 SPACE 0.72 1 20 #10 AHU3, RTU'S 22,26,27 (6) 76 77 SPACE 0.72 1 20 #10 RTU'S 28,29,37,38 6) 78 (9) FACTORY WIRED TO LOAD. 1 RECEIVING RECEPTACLES (6) #8 20 1 0.73 2.31 1.26 1.80 0.72 2 30 #10 WH (JANITOR) (2) 2 83 3 6 ,KW, 208/1 1.80 0.18 1 20 EDC1 EMS EQUIP. 3,9) 84 ' TOTAL 26.03 23.45 22.38 KVA PER NEC ARTICLE 220 217 195 AMPS 187 TOTAL LOAD 71.86 KVA AMPS 199 3 RECEIVING RECEPTACLES (6) #10 20 1 0.72 2.25 4.5 KW, 208/1 4 (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. 5 RECEIVING RECEPTACLES (6) #10 20 1 0.90 2.00 1 25 #10 WH (BREAKROOM) 2 6 (11) THRU CONTACTOR. 7 RECEIVING RECEPTACLES (3,6) #6 20 1 1.22 0.36 1 20 CLAIMS 8 (X) DESIGNATES "SMART" BREAKER. 9 R/0 WATER (6) #10 20 1 0.78 1.44 1 20 #10 LAY -AWAY RECEPTACLES (6) 10 11 MOVEABLE RACKS 2,6) 8 20 1 1.23 1.20 1 20 FLOOR SCRUBBER 12 13 MOVEABLE RACKS (2,6) #8 20 1 1.23 1.20 1 20 FLOOR SCRUBBER 14 15 MOVEABLE RACKS (2,6) #6 20 1 1.23 0.50 1 20 REFRIGERATOR 16 17 EF REAR RESTROOMS 20 1 1.18 0.75 1 20 MICROWAVE 18 19 TELXON CHARGER 20 1 0.60 0.75 1 20 VENDING MACHINE 20 21 EWC'S 20 1 0.65 1.50 1 20 VENDING MACHINE 22 23 EF FAM. TLT. RECEPT 20 1 0.58 1.50 1 20 VENDING MACHINE 24 25 REAR TOILET SENSORS (4) 20 1 0.24 1.25 1 20 COFFEE MAKER 26 27 HAND DRYER (2,6) #8 20 1 2.30 0.50 1 20 REFRIGERATOR 28 29 HAND DRYER 2,6 8 20 1 2.30 1.40 1 20 BRKRM MGR RECEPT 3 30 31 HAND DRYER (2,6) #8 20 1 2.30 1.66 1 20 EF (SMOKING BREAKROOM) 32 33 UH (6) #8 20 1 0.92 0.58 1 20 TRAINING ROOM (3) 34 35 UH 6 8 20 1 0.92 1.20 1 20 TRAINING ROOM 36 37 UH (6) #8 20 0.92 1.24 1 20 #10 MGMT. OFFICE RECEPTS (6) 38 39 UH (6) #8 Ill 20 1 0.92 0.72 1 20 INVOICING /UPC ROOM 40 41 UH 6 8 20 1 0.92 0.36 1 20 BIKE ASSEMBLY 42 43 UH (6), #8 20 1 0.92 3.15 2 50 #6 PANEL L1U (1,3) 44 45 SPARE 11201,1-1 , 2.85 208/120/1 46 47 SPARE 20 1 0.72 1 20 TELE. ALARM BOARD 1,3,9 48 49 SPARE,y �, 1.08 1 20 MANAGER'S IG RECEPT KVA KVA d I , , _ _ ", 1, ,, KVA KVA El VA KVA r I _____F_ :L L1 D2 . GROUND EQUIPMENT SERVES: 208 VOLT DISTRIBUTION 10,000 AIC LOCATION: EDC2 GROUND BUS PANELBOARD SURFACE MOUNT PANELBOARD DESCRIPTION 240/120V, 1 PH, 3W 100A, M. L. 0. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT BRKRPL DESCRIPTION RKR WIRE RK PL DESCRIPTION DESCRIPTION PL RK 1 L RKR WIRE DESCRIPTION 11.81 A 208/120V, 3 PH, 4W SERVES: ELECTRONICS UPC SYSTEM MODULE UPC SYSTEM MODULE 3 208/120/3 15 15 1 1 1 0.25 #6 0.36 2 100A, M. C. B. LOCATION: EDC1 20 20 PAY STATION P.A. /TELE. EQUIP. (9) EP/2 (9 2 4 12.89 0.25 0.05 5 7 UPC SYSTEM MODULE UPC SYSTEM MODULE 2.20 0.12 15 15 1 10.25 10,000 AIC PANEL PROVIDED WITH EDC 17.38 LAY -AWAY CASH WRAPS UP,C SYSTEM, MODULE 6 $ 1 DEDICATED SPACE 9 11 UPC SYSTEM MODULE UPC SYSTEM MODULE 208/120/3 15 15 GROUND BUS 0.25 1.80 15.29 2 30 #10 IBM BLADECENTER 3.6 KW, 208 1 10 12 11 0.25 1.80 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 9 SURFACE MOUNT KVA KVA 20 DESCRIPTION KVA AMPS AMPS AMPS ti M WIRE BRKRPL 24 29 29 PL RK WIRE DESCRIPTION DEDICATED SPACE 14 15 1 ELECTRONICS (6) 13 9.23 #10 20 1 1.08. 1.44 16 1 20 #10 OUTRIGGER TV WALL (6) 2 3 ELECTRONICS (6) 0.50 0.96 18 #10 20 1 0.92 1.44 3 1 20 #10 OUTRIGGER TV WALL (6) 4 5 ELECTRONICS 6 18 19 10 20 1 1 0.72 1.44 1 20 10 OUTRIGGER TV WALL 6 6 7 ELECTRONICS (6) 1 0.50 1.44 #8 20 1 1.08 1.44 100 1 20 #8 OUTRIGGER TV WALL (6) 8 9 ELECTRONICS (6) DRY PIPE COMPRESSOR 2,6 24 #8 20 1 1.08 1.44 1 1 20 #8 OUTRIGGER 7V WALL (6) 10 11 ELECTRONICS HDTV 6 1 8 20 1 PANEL LTS3 (1) 1.20 1.44 1 20 8 OUTRIGGER TV WALL 6 12 13 ELECTRONICS (HDTV) (6) HIRING KIOSK (1) #8 20 1 1.20 1.62 20 1 20 #10 OFFSET TV DISPLAY (6) 14 15 ELECTRONICS (HDTV) (6) 20 #8 20 1 1.20 1.62 SPACE 1 20 #10 OFFSET TV DISPLAY (6) 16 17 ELECTRONICS HDTV 6 SPACE 8 20 1 11.96 1.20 1.62 1 20 10 OFFSET TV DISPLAY 6 18 19 SPARE 39 10.35 #10 20 20 1 1.62 TOTAL 71.50 71.37 1 20 #8„ OFFSET TV DISPLAY (6) 20. 21 SPARE FEEDER LOAD 191.69 KVA 532 AMPS #6 20 1 TOTAL 11.81 13.09 12.89 KVA 1 20 TOTAL LOAD 37.80 SPARE FEEDER LOAD 37.84 22 23 SPARE KVA 118 AMPS 1 20 1 AMPS (1) 50 51 SPACE SPARE 0.56 24 0.54 1 20 #10 SOFTLINES/DSD DESK (1,6) 52 53 SPACE 007 DELI SLICER (6) KVA 1.66 0.36 1 20 PER NEC ARTICLE INVOICING RECEPTACLES 1 54 55 SPACE 23 23 79 64 64 1.26 1 20 AMPS TRAINING ROOM RECEPTS (1) 56 57 SPACE TOTAL LOAD 7.01 KVA 0.54 1 20 AMPS TRAINING ROOM RECEPTS (1) 58 59 SPACE 005 WRAPPER/D04A SCALE O#10 FEEDER LOAD 0.36 1 20 • kiIRING„K)O.SK 60 61 SPACE DELI RECEPTACLES 20 0.54 1 20 #10 AUTO/WAX/PICS,(6) 62 63 SPACE 19.56 KVA 163 0.36 1 20 187 AMPS 64 65 SPACE 0.72 1 20 LPTVS PICS ELECTRONICS 66 67 SPACE 0.72 1 20 #1D TV'S/PICS/TOYS (6) 68 69 SPACE 0.90 1 20 #8 PICS/LPTV (6) 70 71 SPACE 1.08 1 20 6 JIB CRANE 6 72 73 SPACE 1.08 1 20 #10 AHU2, RTU'S 20,21,23-25 (6) 74 75 SPACE 0.72 1 20 #10 AHU3, RTU'S 22,26,27 (6) 76 77 SPACE 0.72 1 20 #10 RTU'S 28,29,37,38 6) 78 79 81 ,SPACE IBM BLAd�ECENTI=R (3) " #10 2 1.26 1.80 0.72 1 1 20 20 RTU'S 30-36 EDC1 RECEPTACLES (9) 80 82 83 3 6 ,KW, 208/1 1.80 0.18 1 20 EDC1 EMS EQUIP. 3,9) 84 ' TOTAL 26.03 23.45 22.38 KVA PER NEC ARTICLE 220 217 195 AMPS 187 TOTAL LOAD 71.86 KVA AMPS 199 FEEDER LOAD 66.36 KVA 184 AMPS L1 D2 . GROUND EQUIPMENT SERVES: 208 VOLT DISTRIBUTION 10,000 AIC LOCATION: EDC2 GROUND BUS PANELBOARD SURFACE MOUNT PANELBOARD DESCRIPTION 240/120V, 1 PH, 3W 100A, M. L. 0. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT BRKRPL DESCRIPTION RKR WIRE RK PL DESCRIPTION DESCRIPTION PL RK 1 L RKR WIRE DESCRIPTION 11.81 A 208/120V, 3 PH, 4W SERVES: ELECTRONICS UPC SYSTEM MODULE UPC SYSTEM MODULE 3 208/120/3 15 15 1 1 1 0.25 #6 0.36 2 100A, M. C. B. LOCATION: EDC1 20 20 PAY STATION P.A. /TELE. EQUIP. (9) EP/2 (9 2 4 12.89 0.25 0.05 5 7 UPC SYSTEM MODULE UPC SYSTEM MODULE 2.20 0.12 15 15 1 10.25 10,000 AIC PANEL PROVIDED WITH EDC 17.38 LAY -AWAY CASH WRAPS UP,C SYSTEM, MODULE 6 $ 1 DEDICATED SPACE 9 11 UPC SYSTEM MODULE UPC SYSTEM MODULE 208/120/3 15 15 GROUND BUS 0.25 1.80 15.29 2 30 #10 IBM BLADECENTER 3.6 KW, 208 1 10 12 11 0.25 1.80 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 9 SURFACE MOUNT KVA KVA 20 DESCRIPTION KVA AMPS AMPS AMPS ti M WIRE BRKRPL 24 29 29 PL RK WIRE DESCRIPTION DEDICATED SPACE 14 15 1 ELECTRONICS (6) 13 9.23 #10 20 1 1.08. 1.44 16 1 20 #10 OUTRIGGER TV WALL (6) 2 3 ELECTRONICS (6) 0.50 0.96 18 #10 20 1 0.92 1.44 3 1 20 #10 OUTRIGGER TV WALL (6) 4 5 ELECTRONICS 6 18 19 10 20 1 1 0.72 1.44 1 20 10 OUTRIGGER TV WALL 6 6 7 ELECTRONICS (6) 1 0.50 1.44 #8 20 1 1.08 1.44 100 1 20 #8 OUTRIGGER TV WALL (6) 8 9 ELECTRONICS (6) DRY PIPE COMPRESSOR 2,6 24 #8 20 1 1.08 1.44 1 1 20 #8 OUTRIGGER 7V WALL (6) 10 11 ELECTRONICS HDTV 6 1 8 20 1 PANEL LTS3 (1) 1.20 1.44 1 20 8 OUTRIGGER TV WALL 6 12 13 ELECTRONICS (HDTV) (6) HIRING KIOSK (1) #8 20 1 1.20 1.62 20 1 20 #10 OFFSET TV DISPLAY (6) 14 15 ELECTRONICS (HDTV) (6) 20 #8 20 1 1.20 1.62 SPACE 1 20 #10 OFFSET TV DISPLAY (6) 16 17 ELECTRONICS HDTV 6 SPACE 8 20 1 11.96 1.20 1.62 1 20 10 OFFSET TV DISPLAY 6 18 19 SPARE 39 10.35 #10 20 20 1 1.62 TOTAL 71.50 71.37 1 20 #8„ OFFSET TV DISPLAY (6) 20. 21 SPARE FEEDER LOAD 191.69 KVA 532 AMPS #6 20 1 TOTAL 11.81 13.09 12.89 KVA 1 20 TOTAL LOAD 37.80 SPARE FEEDER LOAD 37.84 22 23 SPARE KVA 118 AMPS 1 20 1 AMPS 1 20 49 SPARE 0.56 24 1 1.18 2.97 SPACE TOTAL 30 TOTAL 9.48 7.70 7.62 007 DELI SLICER (6) KVA 1.66 KVA 1.18 PER NEC ARTICLE 220 059 SHUNT -TRIP BREAKER 52 53 23 23 79 64 64 1 AMPS TOTAL LOAD 7.24 KVA AMPS D56A FRYER FILTER PUMP (2) FEEDER LOAD TOTAL LOAD 7.01 KVA 24.80 KVA 69 AMPS D56A SHUNT -TRIP BREAKER 56 57 005 WRAPPER/D04A SCALE O#10 FEEDER LOAD 1 17.55 KVA 49 20 AMPS SPARE 58 59 L1 U SERVES: CRITICAL ISOLATED LOCATION: EDC1 PANEL PROVIDED WITH EDC GROUND EQUIPMENT SERVES: 208 VOLT DISTRIBUTION 10,000 AIC LOCATION: EDC2 GROUND BUS PANELBOARD SURFACE MOUNT SURFACE MOUNT DESCRIPTION 240/120V, 1 PH, 3W 100A, M. L. 0. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT BRKRPL DESCRIPTION RKR WIRE RK PL DESCRIPTION DESCRIPTION PL RK 1 L RKR WIRE DESCRIPTION 11.81 A 20 #10 1 3 UPC SYSTEM MODULE UPC SYSTEM MODULE 3 208/120/3 15 15 1 1 1 0.25 #6 0.36 2 2.94 0.66 4 1 1 20 20 PAY STATION P.A. /TELE. EQUIP. (9) EP/2 (9 2 4 12.89 0.25 0.05 5 7 UPC SYSTEM MODULE UPC SYSTEM MODULE 2.20 0.12 15 15 1 10.25 0.25 0.24 (8) 1 1 20 .15 17.38 LAY -AWAY CASH WRAPS UP,C SYSTEM, MODULE 6 $ 1 DEDICATED SPACE 9 11 UPC SYSTEM MODULE UPC SYSTEM MODULE 208/120/3 15 15 1 1 0.25 1.80 15.29 2 30 #10 IBM BLADECENTER 3.6 KW, 208 1 10 12 11 0.25 1.80 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 9 3.15 26 6 6 KVA KVA 20 2.85 KVA AMPS AMPS AMPS ti M _ 24 29 29 13.17 L2B PANELBOARD 2D8/12DV, 3 PH, 4W 600A M. C. B. SERVES: 208 VOLT DISTRIBUTION 10,000 AIC LOCATION: EDC2 GROUND BUS PANEL PROVIDED WITH EDC ISOLATED GROUND BUS SURFACE MOUNT SURFACE MOUNT DESCRIPTION WIRE BRKRPL RKRPL RKR PLBRKR L WIRE DESCRIPTION DESCRIPTION PL RK 1 PANEL L2D1 (1,9) (8) 150 3 11.81 C 20 #10 DEDICATED SPACE 2 3 208/120/3 WH (GM MECH ROOM) (2) #10 1 13.09 #6 50 2 2.94 0.66 4 5 3 PAY STATION 2 , 3 12.89 2.25 1.50 1 20 2.20 0.12 6 7 PANEL L2D2 (9) (8) 200 3 17.38 #8 20 1 DEDICATED SPACE 8 9 208/120/3 FRONT CASH WRAPS 6 7 15.29 1.48 1.50 20 1 0.18 1.64 10 11 '#10 SELF SCAN CHECKOUT (6) 8 9 12.92 #6 20 1 1.08 1.67 12 13 PANEL L2P (9) (8) 150 3 13.17 #6 20 1 DEDICATED SPACE 14 15 208/120/3 FRONT CASH WRAPS (6) 12 13 9.23 0.40 0.60 20 1 0.24 1.67 16 17 X10 FRONT CASH WRAPS (6} 14 15 10.09 0.57 0.36 20 1 0.50 0.96 18 19 PANEL LTS1 (1) (8) 100 3 1.08 2.82 3 60 (8) PANEL LVC (1) 20 21 208%120/3 SELF SCAN, CHECKOUT (1,6) 18 19 1.32 4.62 1.20 1.85 20 1 208/120/3 22 23 21 SPARE 20 21 0.54 3.66 1.20 0.72 20 1 0.50 1.44 24 25 PANEL LTS2 (1) (8) 100 3 1.08 8.74 3 100 (8) PANEL LHC (1) 26 27 208/120/3 DRY PIPE COMPRESSOR 2,6 24 25 1.32 9.02 1.66 0.36 20 1 208/120/3 28 29 27 DObROPERATORS (2) 26 27 0.54 8.10 1.66 1.08 20 1 0.24 0.60 30 31 PANEL LTS3 (1) (8) 100 3 5.48 3 60 (8) PANEL LRX (1) 32 33 208/120/3 HIRING KIOSK (1) 30 31 5.52 #8 20 1 208/120/3 34 35 #6 AQUARIUM WALL RECEPT (6) 32 33 6.34 #10 20 1 0.90 1.44 36 37 SPACE AQUARIUM WALL RECEPT (6) 34 35 9.94 3 100 (8) PANEL LGC (1) 38 39 SPACE AQUARIUM WALL RECEPT (6) 36 37 11.96 2.30 20 1 208/120/3 40 41 SPACE ELECT. /SPORT. C/W (1) 38 39 10.35 #10 20 1 1.08 0.36 42 TOTAL 71.50 71.37 65.44 KVA PER NEC ARTICLE 220 596 595 545 AMPS TOTAL LOAD 208.31 KVA AMPS 577 FEEDER LOAD 191.69 KVA 532 AMPS #6 L2D1 PANELBOARD 208/120V, 3 PH, 4W 225A, M. L. 0. SERVES: MISC. 120V POWER 10,000 AIC LOCATION: EDC2 GROUND BUS PANEL PROVIDED WITH EDC ISOLATED .GROUND BUS SURFACE MOUNT DESCRIPTION DESCRIPTION WIRE RKRPL RKR PL L RK WIRE DESCRIPTION PL RK 1 AIR CURTAIN FANS 4W 20 1 A C 20 #10 STORE FRONT SIGN (2,6,X) 2 3 1 WH (GM MECH ROOM) (2) #10 1 PANEL L2U (1,3) #6 50 2 2.94 0.66 1 20 3 PAY STATION 2 , 3 208/120/1 2.25 1.50 1 20 2.20 0.12 1 20' 5 SELF SCAN CHECKOUT 4 5 PAINT BOOTH (1,6) #8 20 1 0.72 0.87 1 20 7 FRONT CASH WRAPS 6 7 PAINT BOOTH (1) 1.48 1.50 20 1 0.18 1.64 1 20 '#10 SELF SCAN CHECKOUT (6) 8 9 PAINT BOOTH (6) #6 20 1 1.08 1.67 1 20 , #10 FRONT CASH WRAPS (6) 10 11 PAINT BOOTH (6) #6 20 1 1.25 1.67 1 20 #10 FRONT CASH WRAPS (6) 12 13 SIDEWALK REG. (1) 0.40 0.60 20 1 0.24 1.67 1 20 X10 FRONT CASH WRAPS (6} 14 15 PORTRAIT RECEPTACLE (1,10) 0.57 0.36 20 1 0.50 0.96 1 20 #10 s SELF SCAN CHECKOUT (1,6) 16 17 PORTRAIT RECEPTACLE (1,10) 0.72 0.92 20 1 0.50 0.96 1 20 #10 SELF SCAN, CHECKOUT (1,6) 18 19 PORTRAIT RECEPTACLE (1,10) 1.20 1.85 20 1 0.50 1 20 21 SPARE 20 21 PORTRAIT RECEPTACLE (1,10) 1.20 0.72 20 1 0.50 1.44 j 20, 23,LP, HEX FLORf�L CASE 22 23 COURTESY DESK IG (1) 1.20 0.90 20 1 0.54 1.84 1 30 r #4 DRY PIPE COMPRESSOR 2,6 24 25 CASH /COUNTING IG (1) 1.66 0.36 20 1 0.36 0.60 1" 20 27 DObROPERATORS (2) 26 27 JEWELRY CASH WRAP (1) 1.66 1.08 20 1 0.24 0.60 1 20 29 DQOI�QPERATOR�,(2) ,yti 28 29 JEWELRY CASH WRAP LPTV 0.84 1.08 20 1 0.36 0.36 1 20 31 HIRING KIOSK (1) 30 31 JEWELRY WORKSTATION (6) #8 20 1 1.08 1.44 1 20 #6 AQUARIUM WALL RECEPT (6) 32 33 FITTING /PICS (6) #10 20 1 0.90 1.44 1 20 #6 AQUARIUM WALL RECEPT (6) 34 35 ATM (1,6) #10 20 1 0.84 1.44 1 20 #6 AQUARIUM WALL RECEPT (6) 36 37 EXTERIOR RECEPTACLE 2.30 20 1 0.18 0.32 1 20 39 ELECT. /SPORT. C/W (1) 38 39 EXTERIOR RECEPTACLES (6) #10 20 1 1.08 0.36 1 20 #10 ELECTRONICS C/W (6} 40 41 EDC2 RECEPTACLE 0.90 0.14 20 1 0.18 1.36 1 20 #6 SPORT. GOODS C/W (6) 42 TOTAL 11.81 13.09 12.89 KVA PER NEC ARTICLE 220 98 109 107 AMPS TOTAL LOAD 37.80 KVA 105 AMPS FEEDER LOAD 37.84 KVA 105 AMPS L2D2 PANELBOARD 208/120V, 3 PH, 4W SERVES: MISC. 120V POWER 225A, M. L. 0. LOCATION: EDC2 10,000 AIC PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT 240/120V, 1 PH, 3W 100A, M. L. O. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT DESCRIPTION WIRE RKRPL PL RKR PL RK WIRE DESCRIPTION PL RK 1 AIR CURTAIN FANS 4W 20 1 A C 20 #10 STORE FRONT SIGN (2,6,X) 2 3 1 WH (GM MECH ROOM) (2) #10 30 2 2.25 1.50 1 20 #10 VENDING MACHINES (6) 2 3 4.5 KW, 208/1 20 1 0.98 1.00 2.25 1.50 1 20 #10 VENDING MACHINES (6) 4 5 ,AIR, CURTAIN FANS _ 20 20 1 1.48 1.44 1 20 TENANT SIGNAGE (2,X) VENDING MACHINES 6 7 AIR CURTAIN FANS 20 20 1 1.48 1.50 1 20 SEASONAL�(6) VENDING MACHINES 8 9 EF (MECH ROOM)%RECEPTACLE 20 20 1 0.67 0.36 1 20 SEASONAL 6 MOTORIZED CARTS 10 11 MONITOR RACK SYSTEM ; 20 15 1 0.40 0.60 1 20 CIGARETTES (X) DOOR OPERATORS 2 12 13 MONITOR RACK SYSTEM 20 15 1 0.40 0.60 1 20 BLOOD PRESSURE /PICS DOOR OPERATORS (2) 14 15 EAS (3) '. 20 20 1 0.57 0.36 1 20 COSMETICS 6,X ICE MERCHANDISER 16 17 LP OFFICE RECEPTACLES 20 20 1 0.72 0.92 1 " 20 COSMETICS (6,X) UH 18 19 LP OFFICE RECEPTACLES � 20 20 1 1.20 1.85 1 20 COSMETICS (6,X) 22 20_ 21 LP OFFICE RECEPTACLES 20 20 1 1.20 0.72 1 20 COSMETICS LPTV 6,X PORTRAIT RECEPTS 22 23,LP, OFFICE. RECEPTACLES•,,,._. •_.,20 20 1 1.20 0.90 1 20 #6 PORTRAIT RECEPTS 24 25 ICEE MACHINE #10 30 2' 1.66 0.36 1 20 #8 PORTRAIT RECEPTS 26 27 16.0 A,208/1 PHARM DRIVE-THRU RECEPT(2) 20 1 1.66 1.08 1 20 8 CASH/COUNTING RECEPTACLES 28 29 WATER BOOSTER 6 10 20 1 0.84 1.08 1 20 10 COURTESY DESK RECEPT 6 30 31 CARBONATOR (6) #10 r20 1 0.84 1.44 1 20 #10 COURTESY DESK RECEPT (6} 32 33 BEVERAGE DISPENSER 18 ; 20 1 0.36 1.18 1 20 #8 EF (FRONT TLT) (6) 34 3S ICE MACNIN,E , 6 8 " 20 1 1.66 0.65 1 20 10 EWC'S 6 36 37 SPARE D04A/B04 SCALE/LABELERS 20 1 2.30 1 20 #6 HAND DRYER (2,6) 38 39 RTU'S 8-11,17,18 005 WRAPPER (6) 20 1 1.08 2.30 1 20 #6 HAND DRYER {2,6) 40 41 RTU'S 12-15,19 9.23 20 1 0.90 0.14 1 20 TOTAL LOAD FRONT TOILET SENSORS (4 42 TOTAL 17.38 15.29 12.92 KVA 127 108 PER NEC ARTICLE 220 145 AMPS KVA 127 TOTAL LOAD 45.60 AMPS FEEDER LOAD 42.59 KVA 118 AMPS 1 L2P POWER SW6TCHING PANELBOARD 208/120V, 3 PH, 4W SERVES: MISC. 120V POWER 225A, M. L. O. LOCATION: EDC2 10,000 AIC PANEL PROVIDED WITH EDC GROUND BUS SURFACE MOUNT 240/120V, 1 PH, 3W 100A, M. L. O. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT DESCRIPTION WIRE BRK PL RKR PLBRKR W .. W_ JyOWk x WIRE DESCRIPTION PL RK 1 AIR CURTAIN FANS 4W 20 1 1.63 1.02 1 20 #10 STORE FRONT SIGN (2,6,X) 2 3 AIR CURTAIN FANS 0.51 20 1 0.98 1.02 1 20 #10 STORE FRONT SIGN (2,6,X) 4 5 AIR, CURTAIN ...FANS AIC 20 1 0.98 1.00 1 20 8 TENANT SIGNAGE 2,6,X 6 7 SPARE 20.0 A, 208/1 20 1 1.00 1 20 FRONT CASH WRAPS PAY S7A710N TENANT SIGNAGE (2,X) 8 9 SPARE B26 ICING WARMER 20 1 1.08 1 20 #8 SEASONAL�(6) 10 11 SPARE_...,, 15 15 20 1 1.08 1 20 8 SEASONAL 6 12 13 SEASONAL (6 #8 ; 20 1 1.08 0.45 1 20 #10 CIGARETTES (X) 14 15 MUSICAL ESCAPES 18 20 20 1 0.36 0.78 1 20 2.94 24 5 KVA 5 KVA BLOOD PRESSURE /PICS 16 17 SEASONAL 6 8 '. 20 1 1.08 1.36 1 20 10 COSMETICS 6,X 18 19 SEASONAL (6) #8 , 20 1 1.08 1.68 1 20 #10 COSMETICS (6,X) 20 21 FABRIC/PICS 1.32 � 20 1 0.54 1.68 1 20 #10 COSMETICS (6,X) 22 23 BOOTWALL 6,X B 20 1 0.45 0.84 1 20 10 COSMETICS LPTV 6,X 24 SPACE 25 GREETING CARDS (X) 11 20 1 0.20 1.92 1 20 #6 CEILING „FgNS (6),. _ 26 27 GREETING CARDS (X) SPACE 20 1 0.20 0.90 1 20 #8 SEASONAL (6) 28 29 GREETING CARDS X PHARM DRIVE-THRU RECEPT(2) 20 1 0.20 0.90 1 20 8 SEASONAL 6 30 31 GREETING CARDS (X) 21 20 1 0.20 0.90 1 20 #10 PICS/SEASONAL (6� 32 33 GREETING CARDS (X) 22 20 1 0.20 1.08 1 20 X10 ,SEASdNAL� (6)��� 34� 35 GREETING CARDS X 18 20 1 0.20 1.80 1 20 6 LAMPS 6,X 36 37 GREETING CARDS (X) EF (ROTISSERIE),(2,6) 20 1 0.20 1.80 1 20 #6 LAMPS (6;X _ 38 39 GREETING CARDS (X) D04A/B04 SCALE/LABELERS 20 1 0.20 0.20 1 20 22 GREETING CARDS (X) 40 41 SPARE X 005 WRAPPER (6) 20 1 0.20 1 20 SPACE GREETING CARDS X 42 TOTAL 13.17 9.23 10.09 KVA PER NEC ARTICLE 220 110 77 84 AMPS TOTAL LOAD 90 AMPS 32.49 KVA 36.20 FEEDER LOAD KVA 100 AMPS 208/120/3 L2U SERVES: CRITICAL ISOLATED GROUND EQUIPMENT LOCATION: FRONT ELEC. /COMM. ROOM PANEL FURNISHED WITH EDC, INSTALLED BY E.C. TWO -SECTION PANEL SECTION #1: BREAKERS 1-30 208/120V, 3 PH, 4W PANELBOARD SERVES: BAKERY AND DELI 10,000 AIC PANELBOARD PANEL PROVIDED WITH EDC SURFACE MOUNT 240/120V, 1 PH, 3W 100A, M. L. O. 10,000 AIC EQUIPMENT GROUND BUS SURFACE MOUNT DESCRIPTION DESCRIPTION RK WIRE RKR L W .. W_ JyOWk x WIRE DESCRIPTION PL RK WIRE DESCRIPTION 4W SERVES: GROCERY /CHECKOUTS 60 2 1 3 FRONT CASH WRAPS FRONT CASH WRAPS LOCATION: EDC4 #6 20 20 1 1 100A, M. C. 0.51 0.54 10,000 AIC PANEL PROVIDED WITH EDC 1 1 20 20 10 PHARMACY PHARMACY IG RECEPT IG RECEPT 6 2 4 AIC 0.34 0.72 5 7 FRONT CASH WRAPS FRONT CASH WRAP$ _ 2.08 20 20 1 1 0.43 0.72 SPARE � 1 1 20 20 20.0 A, 208/1 PHARMACY IG RECEPT COURTESY CASH WRAPS 6 8 RKRPL 0.34 0.32 9 11 FRONT CASH WRAPS PAY S7A710N SELF SCAN CHECKOUT 20 20 1 1 0.34 B26 ICING WARMER 1 20 RKRPL SPARE SPACE 10 12 20 0.08 13 15 DATA SYSTEMS RACK DATA SYSTEMS RACK 6 10 15 15 1 1 0.40 1 RTU'S 1,2,3, AHU 1 1 20 SPACE SPACE 14 16 R/0 WATER FILTRATION 0.40 17 19 SPARE SPARE 0.36 15 20 1 1 RTU'S 4-7, 16 {6) #10 20 SPACE 0.90 0.17 SPACE SPACE 18 20 R/0 WATER FILTRATION 20 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 5 2.94 24 5 KVA 5 KVA 2.20 18 25 25 KVA AMPS AMPS AMPS 1 17 SPACE 1 L4D1 TWO -SECTION PANEL SECTION #1: BREAKERS 1-30 208/120V, 3 PH, 4W WITH FEED-THRU LUGS SECTION #2: BREAKERS 31-60 225A, M. C. B. SERVES: BAKERY AND DELI 10,000 AIC PANELBOARD PANEL PROVIDED WITH EDC SURFACE MOUNT C.C.D. #2 DESCRIPTION WIRE RK PL 03/23/05 PLBRKR W .. W_ JyOWk x WIRE DESCRIPTION 208/120V, 3 PH, 4W SERVES: GROCERY EQUIPMENT 1 208/120V, 3 PH, 4W SERVES: GROCERY /CHECKOUTS 60 2 4.19 3.74 100A, M. C. B. LOCATION: EDC4 #6 B36 PROOF BOX (2) 2 100A, M. C. B. LOCATION: EDC4 10,000 AIC PANEL PROVIDED WITH EDC 20 #10 FRONT CASH WRAPS (6) 36.0 A 208/1 4 10,000 AIC GROUND BUS 30 2 2.08 1 20 FRONT CASH,., WRAPS 6 .. ,., SPARE � 6 SURFACE MOUNT 20.0 A, 208/1 DESCRIPTION WIRE RKRPL 2.08 1 20 SELF SCAN CHECKOUT PL RK WIRE B26 ICING WARMER DESCRIPTION WIRE RKRPL 0.45 1 20 PL RKR WIRE DESCRIPTION A 20 1 1 RTU'S 1,2,3, AHU 1 1 20 1 1 R/0 WATER FILTRATION 1 20 1 0.36 2 3 RTU'S 4-7, 16 {6) #10 20 SPACE 0.90 0.17 2 3 R/0 WATER FILTRATION 20 20 1 5 0.36 10 20 1 17 SPACE 1 4 5 SEAFOOD RECEPTACLES 6 20 1 SPACE 20 0.55 1.08 0.43 20 1 SPACE 0.90 6 7 M04 SCALE/M11 WRAPPER(4,6 #10 20 1 1.32 0.20 0.60 0.18 0.60 1 1 20 20 20 � SPACE 10 12 8 9 PO4 SCALE / P05 WRAPPER SPARE 20 1 1 1.32 20 6 SEAFOOD FREEZER LTG. (2) 14 SPACE EDC4 RECEPTACLES 10 11 SPARE 0.36 0.60 20 1 20 FRONT CASH WRAP (6) BAKERY/DELI FRZR. HTRS(2,4) 16 17 WASTE OIL TANK 6 SPACE 20 12 13 SPACE 1 20 SPACE BAKERY DELI_. FREEZER LTG 2 18 19 PHARM DRIVE-THRU RECEPT(2) 1 20 SPACE 0.36 0.60 14 15 SPACE 30 POULTRY COOLER HTRS (2,4),.20 31 21 SPARE 20 20 1 3 SPACE 1 16 17 SPACE 22 23 SPARE 1 20 1 AIR CURTAIN FANS (6) 34 1 SPACE 35 18 19 COMPRESSOR HSE AUX PANEL #10 30 3 0.56 36 37 36 37 EF (ROTISSERIE),(2,6) SPACE 26 20 21 208/120/3 30 #8 059 DOUBLE ROTISSERIE (2,6) 38 0.56 D04A/B04 SCALE/LABELERS 1 SPACE 28 SPACE SPACE 22 23 24.7 A, 208/3 40 41 005 WRAPPER (6) #10 20 0.56 30 SPACE SPACE 4.82 24 25 COMPRESSOR HSE AUX PANEL #10 30 3 0.56 24 38 PER NEC ARTICLE 220 AMPS 44 SPACE 007 DELI SLICER (6) 26 27 208/120/3 AMPS 3 30 #8 0.56 KVA 34 12.42 FEEDER 10 SPACE 1 28 29 AMPS 24.7 A, 208/3 48 49 007 DELI SLICER (6) 0.56 20 1 1.18 2.97 SPACE 30 TOTAL 50 51 007 DELI SLICER (6) 2.79 2.79 1.66 KVA 1.18 14 'PER NEC ARTICLE 220 059 SHUNT -TRIP BREAKER 52 53 23 23 AMPS 20 1 20 TOTAL LOAD 7.24 KVA AMPS D56A FRYER FILTER PUMP (2) FEEDER LOAD 013 WORKTOP REFRIG (6) #10 7.01 KVA 19 AMPS L4D2 TWO -SECTION PANEL SECTION #1: BREAKERS 1-30 208/120V, 3 PH, 4W WITH FEED-THRU LUGS SECTION #2: BREAKERS 31-60 225A, M. C. B. SERVES: BAKERY AND DELI 10,000 AIC PANELBOARD PANEL PROVIDED WITH EDC SURFACE MOUNT C.C.D. #2 DESCRIPTION WIRE RK PL 03/23/05 PLBRKR W .. W_ JyOWk x WIRE DESCRIPTION W z�W J z 0 1 208/120V, 3 PH, 4W SERVES: GROCERY /CHECKOUTS 60 2 4.19 3.74 2 45 #6 B36 PROOF BOX (2) 2 100A, M. C. B. LOCATION: EDC4 1.35 0.87 4.19 3.74 20 #10 FRONT CASH WRAPS (6) 36.0 A 208/1 4 10,000 AIC PANEL PROVIDED WITH EDC 30 2 2.08 1 20 FRONT CASH,., WRAPS 6 .. ,., SPARE � 6 GROUND BUS 20.0 A, 208/1 1.35 0.12 2.08 1 20 SELF SCAN CHECKOUT SPARE SURFACE MOUNT 9 B26 ICING WARMER DESCRIPTION WIRE RKRPL 0.45 1 20 PL RKR WIRE DESCRIPTION 900W, 208/1 20 1 1 RTU'S 1,2,3, AHU 1 1 20 1 0.72 0.60 12 1 20 #10 ICE CREAM FRZR/HTRS (2,4,6 2 3 RTU'S 4-7, 16 {6) #10 20 1 0.90 0.17 15 1 20 20 ICE CREAM FREEZER LTG (2) 4 5 COFFEE GRINDER 6 10 20 1 17 0.96 0.60 1 20 10 GROCERY FRZR. HTRS. 2,4,6 6 7 PRODUCE MISTING SPACE 20 1 1.08 0.43 20 1 20 0.90 GROCERY FREEZER LTG (2) 8 9 11 PASTRY CASE ISLANDER EXTE�210R RECEPTACLE 20 20 20 1 1 0.20 0.60 0.18 0.60 1 1 20 20 20 � MEAT/DELI COOLER HTRS.(L,4) SEAFOOD FRZR. HTRS. 2,4 10 12 13 STQCKRM R,EC�EPTACL;ES 3 6),`20 23 SPARE 1 0.86 0.17 1 1 20 6 SEAFOOD FREEZER LTG. (2) 14 15 EDC4 RECEPTACLES 6 20 1 0.36 0.60 1 1 20 FRONT CASH WRAP (6) BAKERY/DELI FRZR. HTRS(2,4) 16 17 WASTE OIL TANK 6 20 20 1 1 1.82 0.34 1 20 SPACE BAKERY DELI_. FREEZER LTG 2 18 19 PHARM DRIVE-THRU RECEPT(2) 1 20 1 0.36 0.60 " 8 1 20 30 POULTRY COOLER HTRS (2,4),.20 31 21 SPARE 20 20 1 3 40 1 20 32 SPARE � 22 23 SPARE 1 20 1 AIR CURTAIN FANS (6) 34 1 20 35 SPARE 24 25 SPACE 1.88 2.80 10 AIR CURTAIN FANS 6 36 37 36 37 EF (ROTISSERIE),(2,6) SPACE 26 27 SPACE 3 30 #8 059 DOUBLE ROTISSERIE (2,6) 38 39 D04A/B04 SCALE/LABELERS 1 SPACE 28 29 SPACE SPACE 40 24.7 A, 208/3 40 41 005 WRAPPER (6) #10 20 SPACE 30 SPACE TOTAL 4.82 2.83 4.50 KVA #10 20 1 40 24 38 PER NEC ARTICLE 220 AMPS 44 45 007 DELI SLICER (6) #10 TOTAL LOAD AMPS 3 30 #8 12.15 KVA 34 12.42 FEEDER 10 LOAD 1 KVA 34 AMPS 24.7 A, 208/3 48 49 007 DELI SLICER (6) L4D3 PANELBOARD TWO -SECTION PANEL SECTION #1: BREAKERS 1-30 208/120V, 3 PH, 4W WITH FEED-THRU LUGS SECTION #2: BREAKERS 31-60 225A, M. C. B. SERVES: BAKERY AND DELI 10,000 AIC LOCATION: EDC4 GROUND BUS (BOTH SECTIONS) PANEL PROVIDED WITH EDC SURFACE MOUNT C.C.D. #2 DESCRIPTION WIRE RK PL 03/23/05 PLBRKR W .. W_ JyOWk x WIRE DESCRIPTION W z�W J z 0 1 1 649 DONUT MACHINE #6 60 2 4.19 3.74 2 45 #6 B36 PROOF BOX (2) 2 3 40.3 A, 208/1 1.35 0.87 4.19 3.74 20 #10 FRONT CASH WRAPS (6) 36.0 A 208/1 4 5 B49A DONUT THERMOLIZER X10 30 2 2.08 1 20 FRONT CASH,., WRAPS 6 .. ,., SPARE � 6 7 20.0 A, 208/1 1.35 0.12 2.08 1 20 SELF SCAN CHECKOUT SPARE 8 9 B26 ICING WARMER 20 15 2 0.45 1 20 PAY STATION (6) SPARE 10 11 900W, 208/1 20 1 0.60 1.64 0.45 1 20 SELF SCAN CHECKOUT 6 SPARE 12 13 BAKERY RECEPTACLES 20 20 1 0.72 20 #10 SELF SCAN (1 6) SPACE 14 15 B07 BREAD SLICER (4) 20 20 1 1.18 20 8 ,CHECKOUT SELF SCAN` CNECKOUT�(1,6} ` SPACE 16 17 B35A OVEN CONTROLS (2,6) #10 20 1 1.58 20 , 6 FRONT CASH WRAPS ' 6 SPACE 18 19 B17 PASTRY CASES (4) 20 20 1 0.90 20 #6 FRONT CASH WRAPS (6) SPACE 20 21 SPARE 20 20 1 1 20 � #6 FRONT CASH WRAPS (6) SPACE 22 23 SPARE 20 20 1 1 20 � 6 FRONT CASH WRAPS 6 SPACE 24 25 SPACE 20 1 1.50 0.26 1 20 ' #10 FRONT CASH WRAP (6) SPACE 26 27 SPACE 20 1 0.96 1 20 I SPARE SPACE 28 29 SPACE 20 1 1.68 0.98 1 20 " 8 AIR 'C'U'R'TAIN `ANS' (8� SPACE 30 MOTORIZED CARTS 31 EF LIGHTS (DELI) (2) 1 20 1 0.50 2.55 3 40 #8 065 8' HOT FOOD CASE (2) 32 33 EH CONTROLS (DELI), (2) 1 _ 20 1 0.30 2.60 #10 AIR CURTAIN FANS (6) 34 7.95 KW, 120/208/3 34 35 EF 'FRYER � � � 8 20 1 � 1.88 2.80 10 AIR CURTAIN FANS 6 36 37 36 37 EF (ROTISSERIE),(2,6) #1,0 1,5 1„ 1.25 2.97 3 30 #8 059 DOUBLE ROTISSERIE (2,6) 38 39 D04A/B04 SCALE/LABELERS 1 20 1 0.54 2.97 SPACE 40 24.7 A, 208/3 40 41 005 WRAPPER (6) #10 20 1 0.96 2.97 SPACE 42 TOTAL 12.26 14.03 42 43 013 WORKTOP REFRIG (6), #10 20 1 1.21 AMPS 119 FEEDER LOAD 42.90 KVA 059 SHUNT -TRIP BREAKER 44 45 007 DELI SLICER (6) #10 20 1 1.18 2.97 3 30 #8 059 DOUBLE ROT ERIE (2,6) 46 47 007 DELI SLICER 6 10 20 1 1.18 2.97 24.7 A, 208/3 48 49 007 DELI SLICER (6) #10 20 1 1.18 2.97 50 51 007 DELI SLICER (6) #10 20 1 1.18 059 SHUNT -TRIP BREAKER 52 53 DO�DEL1 SLICER (6)�� � #10`; 20 1 0.96 1.20 1 20 D56A FRYER FILTER PUMP (2) 54 55 013 WORKTOP REFRIG (6) #10 ' 20 1 1.28 D56A SHUNT -TRIP BREAKER 56 57 005 WRAPPER/D04A SCALE O#10 s 20 1 1.14 1 20 SPARE 58 59 DELI RECEPTACLES 20 1 0.54 1 20 SPARE 60 TOTAL 25.53 22.42 19.56 KVA 163 PER NEC ARTICLE 220 213 187 AMPS TOTAL LOAD 67.51 KVA 187 AMPS 131 FEEDER LOAD 47.07 KVA AMPS L4D4 PANELBOARD 208/,2ov, 3 PH, 4W 225A, M. C. B. SERVES: FRONT VESTIBULE 10,000 AIC LOCATION: EDC4 GROUND BUS PANEL PROVIDED WITH EDC ISOLATED GROUND BUS SURFACE MOUNT C.C.D. #2 DESCRIPTION WIRE BRK PL 03/23/05 PLBRK W .. W_ JyOWk x WIRE DESCRIPTION W z�W J z 0 1 ICE MAKER O 20 2 1.35 0.87 1 20 #10 FRONT CASH WRAPS (6) 2 3 120/208/1 1.35 0.87 1 20 #10 FRONT CASH WRAPS (6) 4 5 ICE MAKER 20 2 1.35 0.87 1 20 10 FRONT CASH,., WRAPS 6 .. ,., 6 7 120/208/1 1.35 0.12 1 20 W 0 SELF SCAN CHECKOUT 8 9 ICE MERCHANDISER (6) #6 20 1 1.56 0.66 1 20 #10 PAY STATION (6) 10 11 ICE BAGGER 6 10 20 1 0.60 1.64 1 20 8 SELF SCAN CHECKOUT 6 12' 13 AIR CURTAIN FANS (6) #8 20 1 1.63 0.96 1 20 #10 SELF SCAN (1 6) 14 15 EAS (3) 20 1 0.57 0.96 1 20 8 ,CHECKOUT SELF SCAN` CNECKOUT�(1,6} ` 16 17 DOOR OPERATORS 2,6 1D 20 1 0.60 1.67 1 20 , 6 FRONT CASH WRAPS ' 6 18 19 DOOR OPERATORS (2,6) #10 20 1 0.60 1.67 1 20 #6 FRONT CASH WRAPS (6) 20 21 VENDING MACHINES (6) #6 20 1 1.50 1.67 1 20 � #6 FRONT CASH WRAPS (6) 22 23 VENDING MACHINES 6 6 20 1 1.50 1.67 1 20 � 6 FRONT CASH WRAPS 6 24 25 VENDING MACHINES (6) #6 20 1 1.50 0.26 1 20 ' #10 FRONT CASH WRAP (6) 26 27 VENDING MACHINES (6) #8 20 1 0.96 1 20 I SPARE 28 29 VENDING MACHINES 6) 6 20 1 1.68 0.98 1 20 " 8 AIR 'C'U'R'TAIN `ANS' (8� 30` 31 MOTORIZED CARTS 20 1 0.36 0.98 >1 20 #8 AIR CURTAIN FANS (6) 32 33 UH'S (6) #8 20 1 _ 1.85 1.48 1 20 #10 AIR CURTAIN FANS (6) 34 35 UH 6) 10 20.1 0.92 1.48 '1 20 10 AIR CURTAIN FANS 6 36 37 DOOR OPERATORS (2,6) #10 20 1 0.60 SPACE38 39 DOOR OPERATORS (2,6) #10,� 20 1 0.60 SPACE 40 41 SPARE 20 1 1.63 SPACE 42 TOTAL 12.26 14.03 16.61 KVA 138 PER NEC ARTICLE 220 102 117 AMPS 119 TOTAL LOAD 42.90 KVA AMPS 119 FEEDER LOAD 42.90 KVA AMPS Lyj N Da p0� D � zr�a�o�uwi z'-^� � oa z �rz �ao$� oawcwi��wo 0 Wo oI-"=rzw �6 w�op 3:5z-zuoK a H oa��oa�`'oaazZa d � oz}'y'�.^FLL Fww�pw a op0�a x¢in xr s= ISSUE BLOCK zwas 10/22/04 OM {ljw�� K m 4, FILE NAME: I �r�Ooow �w"'-"o C.C.D. #2 Noz Qt=/I4NU CCWaW�t�w 01 /24/05 MM O ZO WaoN^ E3L1�'ax � z 03/23/05 C.C.D. #15 W .. W_ JyOWk x � W ^�Gy ('JZr4 W z�W J z 0 xw--n 0 O ISSUE BLOCK 10/22/04 u� FILE NAME: 11/17/04 C.C.D. #2 062504 01 /24/05 C.C.D. #8 ' 03/23/05 C.C.D. #15 04/14/05 F.P.P. 04/20/05 C.C.D. #16 O N co F 0 O (n w W w W 0 ISSUE BLOCK 10/22/04 C.C.D. #1 FILE NAME: 11/17/04 C.C.D. #2 062504 01 /24/05 C.C.D. #8 ' 03/23/05 C.C.D. #15 04/14/05 F.P.P. 04/20/05 C.C.D. #16 CHECKED BY: DRAWN BY: FILE NAME: E4.2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 O U zw w Flo~ c¢irvwio U W U 3g: a O J ¢ w Z -� Z � j S ¢ J aw¢W p o 0 �m¢Z)oe a Qo¢W`' ~a~moZWo\ ��W z wv�z¢mi;.i m�->y z Wdao`-z -tl�cnav)a SHEET: E4.2 LTS1 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 208/120V, 3 PH, 4W 208/12DV, 3 PH, 4W PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: TENANT SPACE 100A, M. L. 0. PANELBOARD NOTES ( ) 0. SERVES: TENANT SPACE EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 AIC LOCATION: TENANT SPACE GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, (1) TERMINATE GROUND ON ISOLATED GROUND BUS. GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. 5 ISOLATED GROUND BUS DESCRIPTION ISOLATED GROUND BUS WIRE DESCRIPTION 1 20 BRKRPL RECEPTACLE 8 2.75 0.36 (2) INSTALL LOCKING DEVICE FURNISHED WITH CASH REGISTER (1) C/0 RECEPTACLES DESCRIPTION 15 20 1 1 0.08 1.20 PL 1 2 20 30 #8 DIGITAL CENTER SCAN STATION 10 12 DESCRIPTION 0.41 1.20 13 15 POWER POLE RECEPTACLES POWER POLE RECEPTACLES SPARE 20 20 1 1 PANELBOARD (LOCK -OFF FOR MAINTENANCE). 0.36 RECEPTACLES (1) 1 B 2 30 8 2.4 KVA, 240/1 SCAN STATION 14 16 SPARE 0.54 1.20 17 19 RECEPTACLES SPACE SPARE 20 1 0.72 1.20 0.36 (3) INSTALL LOCKING DEVICE FURNISHED WITH 50 #6 2.4 KVA, 240/1 DIGITAL PRINTER 18 20 RECEPTACLES 3.84 21 23 SPACE SPACE 1 0.18 20 3.84 20 0.36 0.36 RECEPTACLES 1 7.68 KVA, 240/1 SPACE 22 24 PANELBOARD (LOCK -ON FOR CRITICAL LOAD). 4 TOTAL PER NEC ARTICLE 220 TOTAL LOAD FEEDER LOAD 17.29 7 0.36 20 16.14 KVA AMPS AMPS AMPS 0.18 0.36 1 144 SPARE 135 33.43 KVA KVA 139 33.43 (4) GFI BREAKER. 20 1 20 0.36 TENANT SIGNAGE (2) 1 20 SPARE RECEPTACLES 8 9 SPARE 1.80 FUTURE STYLING BAR 20 1 20 0.60 (5) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. 1 20 SPACE TENANT SIGNAGE (2) 10 11 SPARE 0.58 FUTURE STYLING BAR 20 1 SPACE 1 SPACE 1 20 SPACE SPARE (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR 13 SPACE 15 CLOTHES DRYER 15 SPACE 30 18 SPACE 16 118 17 SPACE SPACE 14 15 SPACE 17 5.0 KW, 208/120/1 VOLTAGE DROP. SIZE EQUIPMENT GROUNDING BLOWER MOTOR 1 20 SPACE AMPS SPACE TOTAL SPACE 16 118 17 SPACE 0.54 RECEPTACLE KVA BLOWER MOTOR 9 1 PER NEC ARTICLE 220 CONDUCTOR PROPORTIONALLY PER NEC. 1.27 11 SPACE AMPS AMPS TOTAL 2.94 1.08 21 1.32 0.54 KVA KVA 0.18 AMPS 9 3.09 PER NEC ARTICLE 220 (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FEEDER LOAD 11 5 9 AMPS AMPS 1 2.94 1 TOTAL LOAD 20 KVA 8 24 AMPS TOTAL 2.82 FAULT CURRENT FOR INTERRUPTING RATINGS. 4.62 ` FEEDER LOAD KVA KVA 9 PER NEC ARTICLE 220 AMPS 24 26 39 SPACE 31 AMPS 46 AMPS 53 TOTAL LOAD (8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. 31.18 87 11.10 KVA 31 29 FEEDER LOAD 11.10 48 KVA 17.34 31 AMPS FEEDER LOAD KVA SPACE (9) FACTORY WIRED TO LOAD. TOTAL 8.74 9.02 8.10 KVA 73 75 68 PER NEC ARTICLE 220 AMPS (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. TOTAL LOAD AMPS 25.86 KVA 72 26.01 72 FEEDER LOAD KVA AMPS (11) THRU CONTACTOR. (X) DESIGNATES "SMART" BREAKER.KVA LPL LOADCENTER 240/12DV, , PH, 3W 150A, M. L. 0. SERVES: PHOTO LAB 10,000 AIC LOCATION: PHOTO LAB GROUND BUS PANEL PROVIDED WITH CABINET ISOLATED GROUND BUS FLUSH MOUNT DESCRIPTION WIRE RKRPL PL RK WIRE DESCRIPTION B 1 DIGITAL PRINTER #6 50 2 3.84 1.20 1 20 RECEPTACLES 2 3.84 2.00 1 25 WATER HEATER (2 4 3 7.68 KVA, 240/1 #10 5 FILM PROCESSOR #8 30 2 2.75 0.54 1 20 COPY PRINT STATION 6 7 5.5 KVA, 240/1 KVAKVA KVA KVA Ky LTS1 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 208/120V, 3 PH, 4W 208/12DV, 3 PH, 4W PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: TENANT SPACE 100A, M. L. 0. 100A, M. L. 0. SERVES: TENANT SPACE EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 AIC LOCATION: TENANT SPACE GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. 5 ISOLATED GROUND BUS DESCRIPTION ISOLATED GROUND BUS WIRE DESCRIPTION 1 20 BRKRPL RECEPTACLE 8 2.75 0.36 9 11 CASH REGISTER (1) C/0 RECEPTACLES DESCRIPTION 15 20 1 1 0.08 1.20 PL 1 2 20 30 #8 DIGITAL CENTER SCAN STATION 10 12 DESCRIPTION 0.41 1.20 13 15 POWER POLE RECEPTACLES POWER POLE RECEPTACLES SPARE 20 20 1 1 0.72 1.20 0.36 RECEPTACLES (1) 1 B 2 30 8 2.4 KVA, 240/1 SCAN STATION 14 16 SPARE 0.54 1.20 17 19 RECEPTACLES SPACE SPARE 20 1 0.72 1.20 0.36 2 50 #6 2.4 KVA, 240/1 DIGITAL PRINTER 18 20 RECEPTACLES 3.84 21 23 SPACE SPACE 1 0.18 20 3.84 20 0.36 0.36 RECEPTACLES 1 7.68 KVA, 240/1 SPACE 22 24 RECEPTACLES 4 TOTAL PER NEC ARTICLE 220 TOTAL LOAD FEEDER LOAD 17.29 7 0.36 20 16.14 KVA AMPS AMPS AMPS 0.18 0.36 1 144 SPARE 135 33.43 KVA KVA 139 33.43 139 20 1 LTS1 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 208/120V, 3 PH, 4W 208/12DV, 3 PH, 4W PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: TENANT SPACE 100A, M. L. 0. 100A, M. L. 0. SERVES: TENANT SPACE EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 AIC LOCATION: TENANT SPACE GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. 5 ISOLATED GROUND BUS DESCRIPTION ISOLATED GROUND BUS WIRE DESCRIPTION 20 WIRE BRKRPL FLUSH MOUNT PLBRKR DESCRIPTION FLUSH MOUNT WIRE DESCRIPTION DESCRIPTION WIRE RK PL PL RK WIRE PLBRKR 20 WIRE DESCRIPTION 1 JUNCTION BOX (1) 0.72 SPARE 20 1 0.36 0.36 RECEPTACLES (1) 1 B 1 C 2 3 JUNCTION BOX SPARE 1.68 0.90 1 JUNCTION BOX (1) SPARE 0.36 0.36 20 1 0.36 0.36 RECEPTACLES 1 20 RECEPTACLE RECEPTACLES 2 3 JUNCTION BOX 1 0.18 20 1 20 0.36 0.36 RECEPTACLES 1 20 SPARE RECEPTACLES 4 5 RECEPTACLE 7 0.36 20 1 20 0.18 0.36 1 20 SPARE RECEPTACLES 6 7 SPARE 20 0.60 20 1 20 0.36 TENANT SIGNAGE (2) 1 20 SPARE RECEPTACLES 8 9 SPARE 1.80 FUTURE STYLING BAR 20 1 20 0.60 SPARE 1 20 SPACE TENANT SIGNAGE (2) 10 11 SPARE 0.58 FUTURE STYLING BAR 20 1 SPACE 1 SPACE 1 20 SPACE SPARE 12 13 SPACE 15 CLOTHES DRYER 15 SPACE 30 18 SPACE 16 118 17 SPACE SPACE 14 15 SPACE 17 5.0 KW, 208/120/1 PER NEC ARTICLE 220 BLOWER MOTOR 1 20 SPACE AMPS SPACE TOTAL SPACE 16 118 17 SPACE 0.54 RECEPTACLE KVA BLOWER MOTOR 9 1 PER NEC ARTICLE 220 FEEDER LOAD 1.27 11 SPACE AMPS AMPS TOTAL 2.94 1.08 21 1.32 0.54 KVA KVA 0.18 AMPS 9 3.09 PER NEC ARTICLE 220 22 FEEDER LOAD 11 5 9 AMPS AMPS 1 2.94 1 TOTAL LOAD 20 KVA 8 24 AMPS TOTAL 2.82 3.09 4.62 ` FEEDER LOAD KVA KVA 9 PER NEC ARTICLE 220 AMPS 24 26 39 LTS2 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 208/120V, 3 PH, 4W 208/12ov, 3 PH, 4W BRKRPL PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: TENANT SPACE 100A, M. L. 0. SERVES: TENANT SPACE a 1 EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 10,000 AIC LOCATION: TENANT SPACE f'1 GC CASH REG (1) GROUND BUS GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. ISOLATED GROUND BUS 4 5 ISOLATED GROUND BUS DESCRIPTION FLUSH MOUNT WIRE DESCRIPTION 20 WIRE BRKRPL FLUSH MOUNT PLBRKR DESCRIPTION RKR WIRE RKRPL DESCRIPTION 1 DESCRIPTION PL RK WIRE DESCRIPTION 20 1 20 1 JUNCTION BOX (1) 0.72 SPARE 20 1 0.36 0.36 RECEPTACLES (1) 1 20 1 RECEPTACLES 2 3 JUNCTION BOX SPARE 1.68 0.90 20 1 SPARE 0.36 0.36 POWER 1 20 5 RECEPTACLES 4 5 RECEPTACLE 1 6 20 1 1 0.18 0.36 1 20 1 RECEPTACLES 6 7 SPARE 8 9 20 1 7 0.36 1 1 20 20 RECEPTACLES 8 9 SPARE 11 SPARE 20 1 20 0.60 20 1 20 1 TENANT SIGNAGE (2) 10 11 SPARE SPACE 20 20 1 1.80 FUTURE STYLING BAR 11 1 20 SPACE SPARE 12 13 SPACE 20 1 20 1 0.58 FUTURE STYLING BAR 13 BLOWER MOTOR SPACE 1 SPACE 14 15 SPACE SPACE 20 TV RECEPTACLE 14 15 CLOTHES DRYER 15 SPACE 30 18 SPACE 16 118 17 SPACE 17 SPACE KVA 16 17 5.0 KW, 208/120/1 PER NEC ARTICLE 220 BLOWER MOTOR 1 20 SPACE AMPS SPACE TOTAL 18 1.08 TOTAL LOAD 1.32 0.54 RECEPTACLE KVA BLOWER MOTOR 9 1 PER NEC ARTICLE 220 FEEDER LOAD 1.27 11 5 AMPS AMPS SPACE 2.94 STEREO RECEPTACLE 21 TOTAL LOAD 20 KVA 8 0.18 AMPS 1 3.09 22 FEEDER LOAD SPACE KVA 9 BLOWER MOTOR AMPS 1 20 LTS3 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 208/120V, 3 PH, 4W 4W BRKRPL PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: TENANT SPACE 0. SERVES: PHARMACY a 1 EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: TENANT SPACE 10,000 AIC LOCATION: PHARMACY f'1 GC CASH REG (1) GROUND BUS GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. PANEL FURNISHED WITH EDC, ISOLATED GROUND BUS 1 ISOLATED GROUND BUS ISOLATED GROUND BUS 4 5 FLUSH MOUNT DESCRIPTION FLUSH MOUNT WIRE DESCRIPTION 20 WIRE BRKRPL 6 PLBRKR PL RKR WIRE DESCRIPTION 1 DESCRIPTION 1 SPARE 1 RECEPTACLES 20 1 20 1 20 0.72 SPARE 1 2 3 SPARE RECEPTACLES (1) 2 20 1 1.80 1 20 1 SPARE 1.68 0.90 4 5 SPARE STYLING BAR POWER 20 1 5 1 20 SPARE 1 6 7 SPARE 1 20 20 1 POLE RECEPTACLES (1 1 20 PLUGMOLD (4) SPARE 1 8 9 SPARE 0.26 7 20 1 LASER PRINTER 1 20 9 SPARE 0.68 10 11 SPARE CASH WRAP (1) 2.04 20 1 20 1 20 1 SPARE 11 12 13 SPACE 20 1 10 1.80 FUTURE STYLING BAR 11 WATER HEATER 2 20 SPACE 25 14 15 SPACE 20 1 20 1 0.58 FUTURE STYLING BAR 13 BLOWER MOTOR SPACE 1 16 17 SPACE 15 SPACE 20 TV RECEPTACLE 14 15 CLOTHES DRYER 15 SPACE 30 18 20 TOTAL 20 16 17 SPACE KVA 16 17 5.0 KW, 208/120/1 PER NEC ARTICLE 220 BLOWER MOTOR 1 20 20 AMPS SPACE 1 18 19 TOTAL LOAD 18 KVA RECEPTACLE AMPS BLOWER MOTOR 20 1 0.18 FEEDER LOAD 1.27 KVA 20 AMPS 21 SPACE 21 LVC 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 2oa/,2ov, 3 PH, 4W 4W BRKRPL PLBRKR Q1.�aX`r mmz WIRE 100A, M. L. 0. SERVES: VISION CENTER 0. SERVES: PHARMACY a 1 EXHAUST FAN (11) 10,000 10,000 AIC LOCATION: VISION CENTER 10,000 AIC LOCATION: PHARMACY f'1 GC CASH REG (1) GROUND BUS GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, ISOLATED GROUND BUS 1 ISOLATED GROUND BUS ISOLATED GROUND BUS 4 5 FLUSH MOUNT DESCRIPTION FLUSH MOUNT WIRE DESCRIPTION 20 WIRE BRKRPL 6 PLBRKR 3/4 HP, 208/1 WIRE PLBRKR WIRE 1 DESCRIPTION GC RECEPTACLES 8 1 RECEPTACLES A B 20 1 1.08 0.72 PLBRK 1 20 1 PRETEST RECEPTACLES (1) 2 3 RECEPTACLES 1.80 1.80 20 1 20 1.68 0.90 STYLING BAR 1 20 STYLING BAR POWER POLE RECEPTACLES 4 5 RECEPTACLES 1.80 1.80 20 1 1 1.50 0.36 1 20 5 POWER POLE RECEPTACLES (1 6 7 PLUGMOLD (4) 0.60 1 20 1 0.18 0.26 7 1 20 LASER PRINTER RECEPTION (1} 8 9 TINT BATH 0.68 1 20 1 CASH WRAP (1) 2.04 9 1 20 LASER PRINTER SPARE 1 10 11 EDGER 1 20 20 1 10 1.80 FUTURE STYLING BAR 11 WATER HEATER 2 20 SPACE 25 12 13 PLUGMOLD / EF 20 1 20 1 0.58 FUTURE STYLING BAR 13 BLOWER MOTOR 20 1 SPACE 0.18 14 15 SPACE 20 TV RECEPTACLE 14 15 CLOTHES DRYER 15 #10 30 2 20 SPACE 20 16 17 SPACE RECEPTACLES 16 17 5.0 KW, 208/120/1 17 BLOWER MOTOR 1 20 20 2.50 SPACE 1 18 19 SPACE 18 19 RECEPTACLE 19 BLOWER MOTOR 20 1 0.18 1.00 1.27 SPACE 20 20 21 SPACE 21 STEREO RECEPTACLE 21 BLOWER MOTOR 20 1 20 0.18 1.30 1 SPACE 22 23 SPACE SPARE 23 BLOWER MOTOR 20 1 20 1 1 20 SPACE SPARE 24 25 TOTAL 2.82 1 4.62 ` 3.66 KVA TOTAL 6.34 PER NEC ARTICLE 220 9.63 24 26 39 SPACE 31 AMPS 46 AMPS 53 TOTAL LOAD AMPS 31.18 87 11.10 KVA 31 29 FEEDER LOAD 11.10 48 KVA 17.34 31 AMPS FEEDER LOAD KVA LHC 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC PANELBOARD PANELBOARD SURFACE MOUNT 2D8/,2DV, 3 PH, 4W 4W BRKRPL PLBRKR Q1.�aX`r mmz WIRE DESCRIPTION SERVES: HAIR CARE SALON 0. SERVES: PHARMACY a 1 EXHAUST FAN (11) 10,000 AIC LOCATION: HAIR CARE SALON 10,000 AIC LOCATION: PHARMACY f'1 GC CASH REG (1) GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL FURNISHED WITH EDC, ISOLATED GROUND BUS 1 20 ISOLATED GROUND BUS 4 5 FLUSH MOUNT DESCRIPTION 2 WIRE BRKRPL 20 GC CASH WRAP 6 PLBRKR 3/4 HP, 208/1 WIRE DESCRIPTION 0.80 0.97 1 20 GC RECEPTACLES 8 9 EXHAUST FAN (11) A B DESCRIPTION C BRKRPL 20 PLBRK GC RECEPTACLES WIRE 1 STYLING BAR 1 EF / RECEPTACLES 20 1 1.80 1.80 1.12 1 20 1 STYLING BAR 2 3 STYLING BAR 3 RECEPTACLES 20 1 20 1.80 1.80 1 20 1 STYLING BAR 4 5 STYLING BAR 5 RECEPTACLES 20 1 20 1.80 0.60 1 20 1 FUTURE TRACK LIGHTING 6 7 STYLING BAR 7 LASER PRINTER 20 1 1.80 0.18 0.68 1 20 1 CASH WRAP (1) 8 9 STYLING BAR 9 LASER PRINTER 20 1 20 1.80 0.58 RETRACTABLE SIDEWALL 1 20 1 EF / RECEPTACLE 10 11 FUTURE STYLING BAR 11 WATER HEATER 2 20 1 25 1.80 0.40 1 20 1 WASHER 12 13 FUTURE STYLING BAR 13 BLOWER MOTOR 20 1 1.80 0.18 1.27 1 20 20 TV RECEPTACLE 14 15 CLOTHES DRYER 15 #10 30 2 20 2.50 0.36 20 1 20 30 RECEPTACLES 16 17 5.0 KW, 208/120/1 17 BLOWER MOTOR 1 20 20 2.50 1.00 1 20 HAIR DRYER 18 19 RECEPTACLE 19 BLOWER MOTOR 20 1 0.18 1.00 1.27 1 20 0.72 0.24 HAIR DRYER 20 21 STEREO RECEPTACLE 21 BLOWER MOTOR 20 1 20 0.18 1.30 1 20 SPARE 22 23 SPARE 23 BLOWER MOTOR 20 1 20 1 1 20 41 SPARE 24 25 SPACE 1.30 1 TOTAL ` 5.48 5.52 TOTAL 6.34 KVA 9.63 SPACE 26 27 SPACE PER NEC ARTICLE 220 46 46 AMPS 53 AMPS 87 31.18 87 TOTAL LOAD SPACE 28 29 SPACE KVA 48 17.34 48 FEEDER LOAD KVA SPACE 30 TOTAL 8.74 9.02 8.10 KVA 73 75 68 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 25.86 KVA 72 26.01 72 FEEDER LOAD KVA AMPS LRX 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC LOCATION: GARDEN CENTER GROUND BUS PANELBOARD SURFACE MOUNT PROTO CYCLE: 2D8/,2DV, 3 PH, 4W BRKRPL PLBRKR Q1.�aX`r mmz WIRE DESCRIPTION 100A, M. L. 0. SERVES: PHARMACY a 1 EXHAUST FAN (11) OZ 20 2 10,000 AIC LOCATION: PHARMACY f'1 GC CASH REG (1) 2 3 3/4 HP, 208/1 GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. 1 20 ISOLATED GROUND BUS 4 5 EXHAUST FAN 11 20 2 0.80 0.96 FLUSH MOUNT 20 GC CASH WRAP 6 7 3/4 HP, 208/1 VA 0.80 0.97 1 20 GC RECEPTACLES 8 9 EXHAUST FAN (11) 20 DESCRIPTION WIRE BRKRPL 20 PLBRK GC RECEPTACLES WIRE DESCRIPTION HP, 208 1 1 EF / RECEPTACLES 0.80 20 1 1.12 0.24 12 1 20 CASH REGISTERS (1) 2 3 RECEPTACLES 20 20 1 0.90 0.72 1 20 0.80 0.82 RECEPTACLES 4 5 RECEPTACLES 16 20 1 20 0.90 0.72 1 20 PILL COUNTERS 6 7 LASER PRINTER 20 1 0.68 0.90 1 20 RECEPTACLES 8 9 LASER PRINTER 0.96 0.82 1 20 1 RETRACTABLE SIDEWALL 0.68 0.68 1 20 20 LASER PRINTER 10 11 WATER HEATER 2 10 25 1 GC RADIANT HTR 2.00 0.18 1 20 1 AUDIO VIDEO MATRIX 12 13 BLOWER MOTOR 27 GC RADIANT HTR 20 1 1.27 0.80 1.14 , 20 #10 EAS (3,6) SPACE 14 15 BLOWER MOTOR 20 1 20 1 20 1.27 GC DOOR OPERATOR 2 30 31 GC DOOR OPERATOR (2) SPACE 16 17 BLOWER MOTOR 1 20 20 1 32 1.27 SHADE CLOTH RECEPTACLES 20 1 SPACE 18 19 BLOWER MOTOR GC DOOR OPERATOR (2) 34 20 1 1.27 20 1 0.72 0.24 1 20 SPACE 20 21 BLOWER MOTOR CF FAN CONTROLLERS #8 20 1 1.30 1.27 20 SPARE 38 SPACE 22 23 BLOWER MOTOR 1.30 20 1 1.27 40 41 SPACE 24 1.30 1 TOTAL ` 5.48 5.52 TOTAL 6.34 KVA 9.63 KVA PER NEC ARTICLE 220 100 80 PER NEC ARTICLE 220 46 46 AMPS 53 AMPS 87 31.18 87 TOTAL LOAD AMPS AMPS 17.34 KVA 48 17.34 48 FEEDER LOAD KVA AMPS LGC PANELBOARD 2D8/,2ov, 3 PH, 4W 100A, M. L. 0. SERVES: GARDEN CENTER 10,000 AIC LOCATION: GARDEN CENTER GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. ISOLATED GROUND BUS SURFACE MOUNT PROTO CYCLE: DESCRIPTION WIRE BRKRPL PLBRKR Q1.�aX`r mmz WIRE DESCRIPTION � 2 zU z w a 1 EXHAUST FAN (11) OZ 20 2 0.80 0.40 1 20 f'1 GC CASH REG (1) 2 3 3/4 HP, 208/1 0.80 1.14 1 20 GC CASH WRAP 4 5 EXHAUST FAN 11 20 2 0.80 0.96 1 20 GC CASH WRAP 6 7 3/4 HP, 208/1 0.80 0.97 1 20 GC RECEPTACLES 8 9 EXHAUST FAN (11) 20 2 0.80 1.26 1 20 GC RECEPTACLES 10 11.3/4 HP, 208 1 0.80 1 20 SPARE 12 EXHAUST FAN (11) 20 2 0.80 0.82 1 20 RETRACTABLE SIDEWALL 14 3/4 HP, 208/1 0.80 0.82 1 20 RETRACTABLE SIDEWALL 16 EXHAUST FAN 11 20 2 0.80 0.41 1 20 RETRACTABLE SIDEWALL 18 [23 3/4 HP, 208/1 0.80 0.82 1 20 RETRACTABLE SIDEWALL 20 FUTURE GC CASH REG (1) 20 1 0.96 0.82 1 20 RETRACTABLE SIDEWALL 22 FUTURE GC CASH WRAP 20 1 0.96 0.82 1 20 RETRACTABLE SIDEWALL 24 25 GC RADIANT HTR 20 1 0.80 0.07 1 20 EF CONTROL CIRCUIT 26 27 GC RADIANT HTR 20 , 0.80 1.14 , 20 #10 EAS (3,6) 28 29 UNIT HEATERS 20 1 1.22 0.60 1 20 GC DOOR OPERATOR 2 30 31 GC DOOR OPERATOR (2) 20 1 0.60 0.60 1 20 GC DOOR OPERATOR (2) 32 33 SHADE CLOTH RECEPTACLES 20 1 0.72 0.60 1 20 GC DOOR OPERATOR (2) 34 35 SHADE CLOTH RECEPTACLES 20 1 0.72 0.24 1 20 TLE KIOSK 36 37 CF FAN CONTROLLERS #8 40 3 1.30 1 20 SPARE 38 39 208/3 1.30 1 20 SPARE 40 41 1.30 1 20 ` SPARE 42 TOTAL 9.58 11.96 9.63 KVA 80 100 80 PER NEC ARTICLE 220 AMPS TOTAL LOAD AMPS 31.16 KVA 87 31.18 87 FEEDER LOAD KVA AMPS � o Lu a oo� (n wza w v <=JwQoFz zNz � �aoBEkima�J� a a mom- wp-'W O ���zo m"F>z�n�m L, a"z w,Ss-a< W � 0¢��oo�-awww� � �c'w=�w ha"V�aZpOz ~4JiZ H J W K w a Zp Q a J �¢.�N�. u�KaooQ. � ¢zt,Fe¢Fwww..QC`�- a. SOF_-�CK�SSK(w/l�H U% a��avwiaaaa� "J W U SCJ z(n p � p DRAWN BY: wwm FILE NAME: w r oow H_ -p PROTO CYCLE: apz LL) n- ?�"" v,c> QiJ rT, E,3wZp°,o�;M�, Z Q1.�aX`r mmz Q r^ wQ.. ..w °wwF4 � 2 zU z w a w OZ SCJ ISSUE BLOCK 11/17/04C.C.D. #21 /2\101/05/051C.C.D. #61 CHECKED BY: DRAWN BY: FILE NAME: E4.3 PROTO CYCLE: 062504 rT, 08/11/04 O N c9 H �o a w OZ W f'1 � 0 0 ISSUE BLOCK 11/17/04C.C.D. #21 /2\101/05/051C.C.D. #61 CHECKED BY: DRAWN BY: FILE NAME: E4.3 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 PANELBOARD SCHEDULES SHEET: E4.3 H3B n CUSTOMER PANELBOARD PANELBOARD r. LREF Q y oa ooir ;. . 7 208/12OV, 3 PH, 4W 150A, M. C. B. SERVES: TLE EQUIPMENT 480/277V, 3 PH, 4W 16.2 2 i �- Tr? PROVIDE 4" SQUARE 'CAST \e T4s$ w`oo _w foo 125A, M. L. 0. SERVES: 480 VOLT TLE EQUIP. 1" CONDUIT (WITH PULL WIRE) 15 10,000 GROUND AIC BUS (7) AIC, SERIES RATED LOCATION: STORAGE ROOM a c J � GROUND BUS PANEL PROVIDED WITH EDC CONSOLE - J ISOLATED GROUND BUS SURFACE MOUNT SURFACE MOUNT PANEL SHALL HAVE FULL LENGTH BUS - JOIST SPACE AND TERMINATE WITH KVA RECOMMENDATIONS PRIOR TO INSTALLATION. DESCRIPTION WIRE RK PL DESCRIPTION L RK WIRE DESCRIPTION 1 TRANSFORMER T3D (9) (8) 70 3 13.78 1 3.88 3 30 #10 AIR COMPRESSOR (2) 2 3 45 KVA, 480/3 1.24 1.08 1.26 1.44 1.92 0.83 0.18 0.87 0.50 0.36 0.90 0.85 1.85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 14.79 1 �� - #10 - #10 10 10 HP, 480/3 46 (11) THRU CONTACTOR. I TOTAL 13.28 3.88 g e 14.79 5 7 PIT HEAT (2,11) KVA 20 1 3.30 3.42 1 20 SHOP LIGHTING (11) 8 9 PIT HEAT (2,11) 23 20 1 3.30 0.69 1 20 EMERGENCY/NIGHT LTG (3) 10 1PIL HEAT 2,11 TYP 6O 20 1 3.30 1 20 SPARE 12 14 ,13 IRRIG. BOOSTER PUMP (2) j 20 3 0.93 1.83 3 15 MAU A, 6.6 A, 480/3 •15 2 HP, 480/3 ) 0.93 1.83 �) 18 FEEDER LOAD i KVA 0.93 1.83 117 AMPS 17 � BY OTHERS. SPACE 20 19 SPACE REF 7 FP2.1 22 21 24 23 (�2 TOTAL 27.14 25.42 23.22 KVA PER NEC ARTICLE 220 98 92 84 AMPS TOTAL LOADI 75.78 KVA 91 AMPS FEEDER LOAD 77.07 KVA 93 AMPS L3D n CUSTOMER s I PANELBOARD r. LREF Q y oa ooir ;. . 7 208/12OV, 3 PH, 4W 150A, M. C. B. SERVES: TLE EQUIPMENT e 16.2 2 i �- Tr? PROVIDE 4" SQUARE 'CAST \e T4s$ w`oo _w foo 9 L3D ALUMINUM JUNCTION BOXICEN 1" CONDUIT (WITH PULL WIRE) 15 10,000 GROUND AIC BUS SURFACE MOUNT PANEL PROVIDED WITH EDC CONSOLE CABLING. PROVIDE 1" CIONDUIT a c J � r(1J riER OF PROVID 7 - . - ; =E.. UTILITY 1" CONDUIT FOR 12004- - J ISOLATED GROUND BUS SURFACE MOUNT DESCRIPTION WIRE RKRPL - JOIST SPACE AND TERMINATE WITH KVA RECOMMENDATIONS PRIOR TO INSTALLATION. L RKR WIRE DESCRIPTION FAULT CURRENT FOR INTERRUPTING RATINGS. s 3 1 WATER HEATER (2) 3 HAND DRYER (2,6) 5 AIR DRYER RECEPTACLE 7 JAUTO DOORS 9 COFFEE MAKER (6) 11 RECEPTACLES 13 SURFACE LIFT (2,6) 15 EAS (3) 17 RECEPTACLES 6 19 TIRE BALANCER 21 1 HP, 208/1 23 TIRE BALANCER 25 1 HP, 208/1 27 VACUUM (2) 29 VACUUM 2 31 SPARE 33 EF (6) 35 ALARM PANEL 3 37 PIT RECEPTACLES (6) 39 PIT LIGHTS (4) 41 SUMP PUMP (3 #10 #10 6 10 #10 #10 10 #10 #8 25 20 20 20 20 20 20 20 20 20 20 15 15 20 20 20 20 20 20 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 2.00 0.60 0.76 1.92 0.54 0.83 1.92 0.83 0.01 0.90 1.62 1.85 2.30 1.68 0.54 0.83 0.87 1.18 0.93 0.72 0.72 0.72 1.84 0.64 0.90 0.92 1.24 1.08 1.26 1.44 1.92 0.83 0.18 0.87 0.50 0.36 0.90 0.85 1.85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 20 20 20 20 20 20 20 20., 20 20 30 20 2 20 20 20 20 20 20 �� - #10 - #10 10 SPAREv ✓� 2 CASH WRAP 1( ) 4 RECEPTACLES 6 AUTO FLUSH / EF 8 RECEPTACLES 10 SPARE 12 RECEPTACLES 14 M,EWC(4)..,F� 6, SURFACE LIFT 2 18 SURFACELIFT� (2)?� PRE -ACTION COMP. (2) 22 FIRE ALARM CONTROLLER 3 24 CONTACTOR CONTROL (9) 26 IRRIGATION CONTROL 28 MAU-1 CONTROLS 30 EF 32 2 HP, 208/3 34 36 UNIT HEATERS (6) 38 UNIT HEATER 40 UNIT HEATERS 6 42 (11) THRU CONTACTOR. I TOTAL 13.78 g e 14.79 13.28 KVA 115 RECEPTACLES AS HIGH 23 3D") 111 PER NEC ARTICLE 220 AS POSSIBLE 22 ) TYP 6O AMPS ! e TYP OF 6 41.85 KVA 16.601 116 TOTAL LOAD AMPS J r f •:'" +60 1 �) PRE -ACTION`' COMPRESSOR +1�7 FEEDER LOAD 42.10 KVA 117 AMPS PIT HEAT _ ------------- __ MOUNT AS HIGH i - r--- -- -- -•� AS POSSIBLE TYP OF 3 i -J H313 VIA CONTACTOR 7V# REF 6-E5--�`��`�! J v o H3B VIA CONTACTOR 9 REF 6-E5 VIA ALARM PANEL REF 3-E5 L3D,a*.4 - - 41 SUMP PUMP WP, GFI, +48" H3B 11%k VIA CONTACTOR REF 6-E5 SWITCHED WP, GFI RECEPTACLE FOR CIRCULATION FAN MOUNT AS HIGH AS POSSIBLE TYP OF 3 PIT POWERAIGHTING PLAN V_0" t-PPI.-aCg VIA ALARM L3D PANEL -1 39 r' REF 3 -ES 44 --7'----7---- I- - -- 1 FROM SWITCH AT i " - (_ TOP OF STAIRS 37 L3D ��� VIA ALARM It. PANEL -rs REF 3-E5 L-� SECURE CONDUIT TO JOIST P1000 UNISTRUT. SPLICE (IF REQUIRED) SHALL NOT ALIGN WITH CONDUIT COUPLINGS - RECEPTACLE IN 4" SQUARE BOX WITH STEEL COVER ATTACH TO UNISTRUT--, li DATA CABLE FINISHED FLOOR UNISTRUT P2072A POST BASE SECURED TO FLOOR WITH FOUR LEAD ANCHORS AND MACHINE SCREWS- RATA CREWS- DATA :4: TERMINATE WITH BUSHING SECURE UNISTRUT TO BAR JOIST BAR JOIST 3/4" CONDUIT, STUB INTO BAR JOIST SPACE BRANCH CIRCUIT CONDUIT PER DRAWINGS SECURE CONDUIT TO UNISTRUT 4" SQUARE BOX. ATTACH TO UNISTRUT 0 I tV ATI ON 05.25.01 rg65 TO PIT RECEPTACLI REF 5-E5 AND PIT HEAT CONT REF 6-E5 TO PIT LIGHTS REF 5 TO PIT SUI PUMP REF 14 13 5 I3 E5 16.600 3 MAKE UP AIR UNIT CONTROL 6 y---- -- - - - - - - - --f/-!! PANEL 16.662 M A M 1� CONTACTOR C3 iREF 6-E5 NOTE: PROVIDE ALL NECESSARY INTERLOCK * I WIRING AND CONDUIT BETWEEN MAU-1, REMOTE I( CONTROL PANEL, AND EF -12. REF: i 38 _ MECHANICAL SCHEDULES AND EQUIPMENT -" MANUFACTURERS WIRING DIAGRAMS. L3-�T 35 i I REF MECHANICAL 1 FURNISH AND INSTALL JUNCTION BOX AND CONDUIT FOR THERMOSTAT AND OVERRIDE TIMER SWITCH FOR CONTROL OF UNIT HEATERS. THERMOSTAT AND OVERRIDE TIMER SWITCH WIRED IN PARALLEL ON 24 VOLT UNIT HEATER CONTROL CIRCUIT. REF MECH. PLANS FOR EXACT THERMOSTAT LOCATION. 7�. PANEL FURNISHED LOOSE WITH EDC, INSTALLED BY CONTRACTOR 3 " NTS 07.25.03 JEL EA03-2 GFI' +50" EF SS !':. ( TYP OF 11 a MAUI rJ nm _3D333 L UUU � If J 30 L3D i 3 iib J 1 I' r ' ! 45. UUt) �) TYP OF 3 4 I ' E5 17 I _L3D - AT STRUCTURE FOR Ii it) I I - - - - - - - - - - - I� ! 11 UUU I 10 L3D ! � tt i } 2'i MOUNT �S� 217 L3� I 7 TYP OF 3a 1� 13 LD3 IE NEMA 6-20R i 4 ' i RECEPTACLE L3D r ; ; TYP OF 2 TYP OF 9 PROVIDE ON/OFF SAFETY SWITCH FOR UNIT HEATER. TYP OF 111.. CENTRAL VACUL* +50t- TO 50 - TO BOOSTER PUMP. REF CIVIL DRAWINGS FOR LOCATION--' AIR COMPRESSOR ( +60 MECHANICAL- LPTV, +90 r� PUSH BUTTON MOUNTED DIRECTLY BENEATH COUNTER TOP G ?- = ?7 I LUBE AND r/'~ I TIRE 11! MOUNTING c fff AREA i 18,.; 1 14I� F:� L3D L3D - 1 III y i 11; s --- - 19 L3D D40` GFI 16 412 L3 t L 16.603 L3D J 16.650 A I 16.228 J 16 TOILE 3D EF j 1 GFI I a1_31D t i U 16.653 4 i EF (PAT. 1/3 L3D f 8 1 29� 1 L3D 27 H3B +96' CONTACTOR13 O W +60" C1 ( ; T +72" 16.220 L3D __� I I ROUTING COORDINA !? 5 �a�111B p CONDUITS FWATtt' ®; An �f I MECHANICAL ('IPtsf 2 +54- 11 n CUSTOMER s I TO SAIL SWI' r. LREF Q y oa ooir ;. . 7 2-E5 w�`xm o€ IN e 16.2 2 i �- Tr? PROVIDE 4" SQUARE 'CAST \e T4s$ w`oo _w foo 9 L3D ALUMINUM JUNCTION BOXICEN 1" CONDUIT (WITH PULL WIRE) 15 AT DOOR HEADER FOR ICAME" os<t*om�aw4151 ` CABLING. PROVIDE 1" CIONDUIT a c J � r(1J riER OF PROVID 7 - . - ; =E.. UTILITY 1" CONDUIT FOR 12004- - J IF n��onkKo'abtzz<P LOCATION WITH MANUFACTURER'S BOLLARD 1" CONDUIT FOR 120V I.GN-• i� - JOIST SPACE AND TERMINATE WITH IrwOww FaQ z J RECOMMENDATIONS PRIOR TO INSTALLATION. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE EAS BUSHING. COORDINbTE+14'-0" MOUNT FIXTURE TO CEILING FAULT CURRENT FOR INTERRUPTING RATINGS. s 3 INSTALLATION WITH _-. F BETWEEN JOIST x cn m d MANUFACTURER'S REQUIREMENTS (9) a a TYP OF 16 i FOR IRRIGATION (11) THRU CONTACTOR. I 16.020 (X) g e +36" 4 WP, GFI MOUNT e RECEPTACLES AS HIGH 3D") s ' AS POSSIBLE 22 ) TYP 6O ! e TYP OF 6 S � X16.610 24 16.601 `s 4� J r f •:'" +60 1 �) SECURE CONDUIT TO JOIST P1000 UNISTRUT. SPLICE (IF REQUIRED) SHALL NOT ALIGN WITH CONDUIT COUPLINGS - RECEPTACLE IN 4" SQUARE BOX WITH STEEL COVER ATTACH TO UNISTRUT--, li DATA CABLE FINISHED FLOOR UNISTRUT P2072A POST BASE SECURED TO FLOOR WITH FOUR LEAD ANCHORS AND MACHINE SCREWS- RATA CREWS- DATA :4: TERMINATE WITH BUSHING SECURE UNISTRUT TO BAR JOIST BAR JOIST 3/4" CONDUIT, STUB INTO BAR JOIST SPACE BRANCH CIRCUIT CONDUIT PER DRAWINGS SECURE CONDUIT TO UNISTRUT 4" SQUARE BOX. ATTACH TO UNISTRUT 0 I tV ATI ON 05.25.01 rg65 TO PIT RECEPTACLI REF 5-E5 AND PIT HEAT CONT REF 6-E5 TO PIT LIGHTS REF 5 TO PIT SUI PUMP REF 14 13 5 I3 E5 16.600 3 MAKE UP AIR UNIT CONTROL 6 y---- -- - - - - - - - --f/-!! PANEL 16.662 M A M 1� CONTACTOR C3 iREF 6-E5 NOTE: PROVIDE ALL NECESSARY INTERLOCK * I WIRING AND CONDUIT BETWEEN MAU-1, REMOTE I( CONTROL PANEL, AND EF -12. REF: i 38 _ MECHANICAL SCHEDULES AND EQUIPMENT -" MANUFACTURERS WIRING DIAGRAMS. L3-�T 35 i I REF MECHANICAL 1 FURNISH AND INSTALL JUNCTION BOX AND CONDUIT FOR THERMOSTAT AND OVERRIDE TIMER SWITCH FOR CONTROL OF UNIT HEATERS. THERMOSTAT AND OVERRIDE TIMER SWITCH WIRED IN PARALLEL ON 24 VOLT UNIT HEATER CONTROL CIRCUIT. REF MECH. PLANS FOR EXACT THERMOSTAT LOCATION. 7�. PANEL FURNISHED LOOSE WITH EDC, INSTALLED BY CONTRACTOR 3 " NTS 07.25.03 JEL EA03-2 GFI' +50" EF SS !':. ( TYP OF 11 a MAUI rJ nm _3D333 L UUU � If J 30 L3D i 3 iib J 1 I' r ' ! 45. UUt) �) TYP OF 3 4 I ' E5 17 I _L3D - AT STRUCTURE FOR Ii it) I I - - - - - - - - - - - I� ! 11 UUU I 10 L3D ! � tt i } 2'i MOUNT �S� 217 L3� I 7 TYP OF 3a 1� 13 LD3 IE NEMA 6-20R i 4 ' i RECEPTACLE L3D r ; ; TYP OF 2 TYP OF 9 PROVIDE ON/OFF SAFETY SWITCH FOR UNIT HEATER. TYP OF 111.. CENTRAL VACUL* +50t- TO 50 - TO BOOSTER PUMP. REF CIVIL DRAWINGS FOR LOCATION--' AIR COMPRESSOR ( +60 MECHANICAL- LPTV, +90 r� PUSH BUTTON MOUNTED DIRECTLY BENEATH COUNTER TOP G ?- = ?7 I LUBE AND r/'~ I TIRE 11! MOUNTING c fff AREA i 18,.; 1 14I� F:� L3D L3D - 1 III y i 11; s --- - 19 L3D D40` GFI 16 412 L3 t L 16.603 L3D J 16.650 A I 16.228 J 16 TOILE 3D EF j 1 GFI I a1_31D t i U 16.653 4 i EF (PAT. 1/3 L3D f 8 1 29� 1 L3D 27 H3B +96' CONTACTOR13 O W +60" C1 ( ; T +72" 16.220 L3D __� I I ROUTING COORDINA !? 5 �a�111B p CONDUITS FWATtt' ®; An �f I MECHANICAL ('IPtsf 2 +54- 11 n CUSTOMER (PART SERVICE 3j TIRE SALES y oa ooir ;. . 7 C. C. D. #5 w�`xm o€ IN BATTERY TIRE jSELECTOR', I`` LOOKUP +8'-6" f 2 TYP OF 4 n 10/22/04 C.C.D. #1 FILE NAME: ; TIRE SALES y oa ooir ;. . 7 C. C. D. #5 w�`xm o€ IN 11H 10 109 L3D 16.410 ' 16.2 2 i �- Tr? PROVIDE 4" SQUARE 'CAST \e T4s$ w`oo _w foo 9 L3D ALUMINUM JUNCTION BOXICEN 1" CONDUIT (WITH PULL WIRE) 15 AT DOOR HEADER FOR ICAME" os<t*om�aw4151 ` CABLING. PROVIDE 1" CIONDUIT 3p=1F)&.ww&oIs�z izZa J J (WITH PULL WIRE) FROM WUNCTION r(1J riER OF PROVID 7 - . - ; =E.. UTILITY 1" CONDUIT FOR 12004- - J BOX TO ACCESSIBLE SALES AREA n��onkKo'abtzz<P LOCATION WITH MANUFACTURER'S BOLLARD 1" CONDUIT FOR 120V I.GN-• i� - JOIST SPACE AND TERMINATE WITH IrwOww FaQ z J RECOMMENDATIONS PRIOR TO INSTALLATION. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE EAS BUSHING. COORDINbTE+14'-0" FAULT CURRENT FOR INTERRUPTING RATINGS. m35Noz INSTALLATION WITH _-. F _�_�------------ x cn m d MANUFACTURER'S REQUIREMENTS (9) FACTORY WIRED TO LOAD. (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. FOR IRRIGATION BATTERY TIRE jSELECTOR', I`` LOOKUP +8'-6" f 2 TYP OF 4 0 AUTO FROM PIT ALARM PANEL REF 3-E5 jf-- - H3B-7 -��- H3B-9 i--- H3B-11 PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, 20A 600V CONTACTS, IN NEMA1 ENCLOSURE PIT HEATCO_ 6 NTS 07.25.03 CENTER LIGHTING PLAN GENERAL AUTO CENTER NOTES 1. SERVICE PIT: NON -CLASSIFIED AREA PER NEC TABLE 514.3(B)(1). THIS IS A NON -DISPENSING FACILITY, WHERE EXHAUST VENTILATION IS IN EXCESS OF 1 CFM PER SQUARE FOOT OF FLOOR AREA TAKEN LESS THAN 12" ABOVE FLOOR. KEYNOTES 16.020 PROVIDE PORCELAIN KEYLESS FIXTURE AND 10OW A-19 ROUGH SERVICE LAMP. 16 220 INSTALL PREFABRICATED ELECTRICAL DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR TERMINATE GROUND ON ISOLATED GROUND BUS. 10/22/04 C.C.D. #1 FILE NAME: ; TIRE SALES y oa ooir ' f C. C. D. #5 w�`xm o€ IN AND IS AN ETL LISTEDOf C.C.D. #8 / +54" TYP OF 3 L3D 28 T4s$ w`oo _w foo 16.227 ELECTRIC WATER COOLER RECEPTACLE: I I 1" CONDUIT (WITH PULL WIRE) CONCEAL WITHIN CABINET PER L3q(PART 3/3) os<t*om�aw4151 ` TO REMOTE FOR DATA CABLE 3p=1F)&.ww&oIs�z izZa J J cna��on�,,W aQNNW �ao��a„9S r(1J riER OF PROVID 7 - . - ; =E.. UTILITY 1" CONDUIT FOR 12004- - J VOLTAGE DROP. SIZE EQUIPMENT GROUNDING n��onkKo'abtzz<P LOCATION WITH MANUFACTURER'S BOLLARD 1" CONDUIT FOR 120V I.GN-• i� - J IrwOww FaQ z J RECOMMENDATIONS PRIOR TO INSTALLATION. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE 16.600_ FAULT CURRENT FOR INTERRUPTING RATINGS. m35Noz I�--._�_- _-- _-. F _�_�------------ x cn m d N 0 (9) FACTORY WIRED TO LOAD. (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. FOR IRRIGATION (11) THRU CONTACTOR. I 16.020 (X) u! +36" J CONTROLLER 3D") I (3) 1-1/4" CONDUITS Ste_ T'. 22 ) FOR SITE IRRIGATION-�� ' A J X16.610 24 16.601 J r f •:'" +60 1 �) PRE -ACTION`' COMPRESSOR +1�7 PRE -ACTION PANEL BY OTHERS. III REF 7 FP2.1 AUTO CENTER POWER PLAN (�2 0 AUTO FROM PIT ALARM PANEL REF 3-E5 jf-- - H3B-7 -��- H3B-9 i--- H3B-11 PROVIDE ELECTRICALLY HELD CONTACTOR WITH 120V COIL, 20A 600V CONTACTS, IN NEMA1 ENCLOSURE PIT HEATCO_ 6 NTS 07.25.03 CENTER LIGHTING PLAN GENERAL AUTO CENTER NOTES 1. SERVICE PIT: NON -CLASSIFIED AREA PER NEC TABLE 514.3(B)(1). THIS IS A NON -DISPENSING FACILITY, WHERE EXHAUST VENTILATION IS IN EXCESS OF 1 CFM PER SQUARE FOOT OF FLOOR AREA TAKEN LESS THAN 12" ABOVE FLOOR. KEYNOTES 16.020 PROVIDE PORCELAIN KEYLESS FIXTURE AND 10OW A-19 ROUGH SERVICE LAMP. 16 220 INSTALL PREFABRICATED ELECTRICAL DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR TERMINATE GROUND ON ISOLATED GROUND BUS. 10/22/04 C.C.D. #1 FILE NAME: INFORMATION PURPOSES ONLY. THE ENTIRE w y oa ooir ASSEMBLY WILL ARRIVE COMPLETELY C. C. D. #5 w�`xm o€ IN AND IS AN ETL LISTEDOf C.C.D. #8 / ASSEMBLY. C.C.D. #13 T4s$ w`oo _w foo 16.227 ELECTRIC WATER COOLER RECEPTACLE: o w 3Nar CONCEAL WITHIN CABINET PER C.C.D. #16 os<t*om�aw4151 MANUFACTURERS REQUIREMENTS. p 3p=1F)&.ww&oIs�z izZa 16.2281NSTALL RECEPTACLE IN UPPER RIGHT HAND J cna��on�,,W aQNNW �ao��a„9S r(1J riER OF PROVID 7 - . - ; =E.. CL rcz X r�F wtit-mo `W ��F--���s-��� 16.232 AUTOMATIC DOOR OPERATOR VERIFY VOLTAGE DROP. SIZE EQUIPMENT GROUNDING n��onkKo'abtzz<P LOCATION WITH MANUFACTURER'S CONDUCTOR PROPORTIONALLY PER NEC. IrwOww FaQ z J RECOMMENDATIONS PRIOR TO INSTALLATION. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE � LJ U)Z¢m ALL CONDUIT AND WIRING SHALL BE CONCEALED AT MAIN ENTRANCE DOORS. 16.238 AUTOMATIC DOOR CONTROLS: INSTALL, in BENEATH COUNTER, ACCESS CONTROL owtZ.- oKwoW WI CONSOLE FURNISHED TH AUTOMATIC F_ 20 DOOR. PROVIDE JUNCTION BOXES, CONDUITS, �Wa'=�7 �Wa�en0 AND LOW VOLTAGE WIRING (SHOWN DASHED) p - AS REQUIRED. COORDINATE EXACT WZaoY��W LOCATIONS AND REQUIREMENTS WITH z Li"'ax °"' �pWK ._W MANUFACTURER'S RECOMMENDATIONS PRIOR J Z u�l TO INSTALLATION. D W�wzrH cn 16.412 AUTOMATIC LAVATORY, URINAL AND WATER z W`"m m CLOSET CONTROLS: PROVIDE JUNCTION o `.I~ BOXES, CONDUITS, RECEPTACLES AND LOW VOLTAGE WIRING (SHOWN DASHED) AS REQUIRED. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH MANUFACTURER'S E D T S 0 1 TI N 16.422 SMOKE DETECTOR: MOUNT WITHIN 12" OF ROOF STRUCTURE OR ON CEILING. PROVIDE CONNECTIONS CONFIGURED FOR FAIL-SAFE 0 TI N 16.441 NOT USED 16.445 ELECTROMAGNETIC LOCK: INSTALL PUSH BUTTON, MOT10N SENSOR AND LOW VOLTAGE TRANSFORMER FURNISHED WITH DOOR HARDWARE PER MANUFACTURERS INSTRUCTIONS. PROVIDE JUNCTION BOX(ES), CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED. MOTION SENSOR SHALL BE ON LUBE AND TIRE MOUNTING AREA SIDE OF DOOR. SET MOTION SENSOR TO RELEASE LOCK FOR 20 SECONDS UPON ACTIVATION. 16.600 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) MOUNTED 2" ABOVE AND 8" IN FROM STRIKE SIDE OF DOOR FRAME. 16.601 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) ADJACENT TO AND EVEN WITH TOP OF DOOR FRAME. 16.603 PROVIDE RECESSED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +80". (UNLESS NOTED OTHERWISE). 16.610 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX (WITH VERTICAL RACEWAY) AT +84" (UNLESS NOTED OTHERWISE). 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT SLEEVE WITH BUSHINGS ABOVE BAR JOIST (UNLESS NOTED OTHERWISE). 16.653 CONDUIT SLEEVE: PROVIDE 2" CONDUIT (WITH PULL WIRE) FROM 8" BELOW CEILING TO 12" ABOVE CEILING, TURN 90 DEGREES AND EXTEND TO NEAREST ACCESSIBLE CEILING SPACE. TERMINATE WITH BUSHINGS. 16.662 AXP CONDUIT SLEEVE: PROVIDE (2) 3/4" SCH 80 PVC SLEEVES WITH A 3/4" 90 DEG ELBOW POINTING DOWN. LOCATE THE FIRST SLEEVE 60" FROM OUTSIDE CORNER OF BUILDING (UNLESS NOTED OTHERWISE) AND SECOND SLEEVE 18" OC, WITH THE VERTICAL CENTERLINE OF BOTH 3/4" ELBOWS 10" FROM WALL. PENETRATE EXTERIOR WALL 6" BELOW BOTTOM CHORD OF BAR JOIST AND SEAL AROUND THE CONDUIT ON THE OUTSIDE WITH UV RATED SEALANT. PANELBOARD NOTES ISSUE BLOCK TERMINATE GROUND ON ISOLATED GROUND BUS. 10/22/04 C.C.D. #1 FILE NAME: 11/17/04 C.C.D. #2 ZL 12/16/04 C. C. D. #5 .4 01/24/05 C.C.D. #8 / 02/28/05 C.C.D. #13 04/14/05 F.P.P. 04/20/05 C.C.D. #16 As 06/02/05 C.C.D. #18 REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. z (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR - ¢w¢w VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CHECKED BY: TERMINATE GROUND ON ISOLATED GROUND BUS. DRAWN BY: -WL- O FILE NAME: E5 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 (1) TERMINATE GROUND ON ISOLATED GROUND BUS. -WL- O (2) INSTALL LOCKING DEVICE FURNISHED WITH E W Lau N PANELBOARD (LOCK -OFF FOR MAINTENANCE). g (3) INSTALL LOCKING DEVICE FURNISHED WITH Jw PANELBOARD (LOCK -ON FOR CRITICAL LOAD). Q70 0 (4) GFI BREAKER. w v> (5) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. z (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR - ¢w¢w VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR PROPORTIONALLY PER NEC. IrwOww FaQ z J (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE � LJ U)Z¢m FAULT CURRENT FOR INTERRUPTING RATINGS. m35Noz a w (8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. x cn m d N 0 (9) FACTORY WIRED TO LOAD. (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. (11) THRU CONTACTOR. o (X) DESIGNATES "SMART" BREAKER. ; L Lo o 0 F=<> -WL- O E W Lau N g fns Jw Q70 0 J awaLi w v> inmmo A z J - ¢w¢w >-a�oo IrwOww FaQ z J � LJ U)Z¢m m35Noz a w d x cn m d N 0 AUTO CENTER ELECTRICAL PLANS AND SCHEDULES SKYLIGHT INSTALL FURNISHED ALS 5000 SHOULLDD BE LEVEL WITH TOP OF, TOP ANALOG LIGHT SENSOR _ LIGHT SENSOR AND BOX , _----�"""""` SKYLIGHT CURB _CENTERED IN SKYLIGHT ' SAFETY f� CAGE __. :t I� � ,•^,r�� UNISTRUT'___`_� 1/4" ANGLE SUPPORT--. w f P I UNISTRUT-` BAR JOIST TYP SUPPORT CONDUIT FROM UNISTRUT AS I REQUIRED PER NEC r4 ALS M OU N 1/2"C JUNCTION BOX ING - S 01.28.05 WEATHERHEAD EMS CABLES (EACH SHALL HAVE A DRIP LOOP) WRAP CABLES WITH OUTDOOR SPIRAL WRAP OUTDOOR SENSOR ASSEMBLY. (PANDUIT OR EQUAL) --r ATTACH TO CONDUIT WITH 3/8"x2-1/8" U -BOLTS FURNISHED WITH U -BOLTS WITH KIT MOUNT PHOTO SENSOR NUTS AND LOCK FACING NORTH WASHERS AKCTDP PHOTO-OD2 ALS ODS o 0 NORTH1 u OTS FRONT VIEW t -b< F I ODS REF 2-EM1 ALS •••.......••••........• INSTALLED BY EDC OTS MANUFACTURER FIELD INSTALLED I 31 NOTE: OWNER WILL FURNISH ALL EMS I I ...........'..A).8..........................IQ220 ...........QC C ...... . AK2 XM -101a .. i ,,,I II i MSB1 i, BRKR ( I ! 1 .......... ...... ::................. ...................................... i I PLM (2) DANFOSS 91-018 1 ! 1 BAP (GRAY) CABLES ....... .....1. ......... L........... I I MSB1 i (AI8) iJ.,........................ 1 ................. i I AK2 XM -2056 :::..................................I (DOB) :,.,,........! I 1..,...,...,._.......... . ............. ,:.........!..........!..........,.I I CABLES FOR INSTALLATION BY E.M.C. SALES ARE #t I ! AK2 CM -101a ADDRESS 4 � ROOF I (1) DANFOSS 91-018 .............. .................. (GRAY) CABLE a ��• i TERMINATOR....::::I••. .. . I --M-•-- I IN 1/2" C. TO V02L6 I MASTER FIXTURE IN ,._�------------•--�- SALES AREA AK2LBDD ROOF DECK SPARE COMM I I ................... 4 CABLE TO RACK B I TO EMS BACKBOARD REM1 ! 485 BUS SLAVE NETWORK ETHERNET ETHERNET I CBGATE2 BOARD MOUNTED (DANFOSS 91-016 (BLUE)) CABLE CABLE •....... ! INSIDE PSP TYP I..,,. AKC55-O I I ............................... ....I ...... ....,.... { I �I I MASTER i PSP ......!,..I PSP �.......' I RACK "D" RACK "C" I RACK "B" RACK "A" o i + H1P1 I i I H1 P2 i, ! '! ..,_... I CONTROLLER CONTROLLER ONTROLLER CONTROLLER G H T I...:::::::::::::::::::::::::::::::::.......................... EDC1 COMPRESSOR I ! COMPRESSOR I L._•—.—•—•—.—•— ——.—.—•—._._. _._. _._._._._._._•—.—._._._._._._._._.J FE13 L — —— HOUSE#2 _ ___J L----HOUSE#1 --- J MODEM ETHERNET CARD 485 BUS SLAVE NETWORK (DANFOSS 91-016 (BLUE)) ETHERNET CARD INSTALLER TO PROVIDE INTERCONNECTION TO RTC 34 (RTU 34) BETWEEN RTC'S IN ALL AHU'S AND RTU'S TO RTC 35 (RTU 35) DANFOSS 91-016 (BLUE), TYP DANFOSS 91-016 (BLUE), TYP OF 3 AHU'S DANFOSS 91-016 (BLUE) DANFOSS 91-016 (BLUE) TYP UNLESS NOTED OTHERWISE CO2 SENSOR: TEXAS INSTRUMENTS 4GS. CONTROLS AMOUNT OF OUTSIDE AIR SUPPLIED. MOUNT ON COLUMN AT +78". TYPICAL DANFOSS 91-018 (GRAY) S-34 S-33 S-32 S-31 S-30 S-29 S-38 S-37 S-28 TS -2 S-23 TS -1 S-1 S-2 S-3 S-- S-5 120V INTRFACE RELAY (TLE LIGHTING) REF 2-E5 r._. _._._._._., I I I................I I i ! R I i I \_DANFOSS I 91-016 (BLUE) L._•_•_,_•_ _ - — - i CBGATE2 BOARD MOUNTED INSIDE PSP TYP _ . F DANFOSS ! 91-016 (BLUE)! ! ..... .......... ........................... ..,......I ! PSP ! PSP i...H2P ....... ......L2P....... ...... I ::I.:....I::............................:........................... I I } I L TERMINATOR I ' EDC2 ' L._._._._._._._•—._._._._._.J /-DANFOSS 91-018 (GRAY), TYP OF 4 RTU'S S-6 S-7 S-16 S-20) (S-24 OUTDOOR SENSOR 2 ASSEMBLY MOUNTING V02LB BOARD ADDRESS #1 Zcn o P # DESCRIPTION 1 SALES LIGHT DIMMING 2 U)WQN4NN PROTO CYCLE: p�WaW ;��wZ DOCUMENT DATE: ��MMO � zXYOI �W\za-N'�'�w O,Z CV (_0a F D fn L ma zFina� J WZx�W Z zw—� 0 Q LLI CL J oaC>z��.i �i IDS -2 02 o o uj a V) IDS -1 Waco z a- z V) a �vViana CO2 CO2 RTC RTC RTC RTC RTC RTC RTC RTC RTC AK2 RTC AK2 RTC RTC RTC RTC RTC RTC RTC RTC RTC TERMINATOR RTC RTU -34 RTU -33 RTU -32 RTU -31 RTU -30 RTU -29 RTU -38 RTU -37 RTU -28 AHU-2 RTU -23 AHU-1 RTU -1 RTU -2 RTU -3 RTU -4 RTU -5 RTU -6 RTU -7 RTU -16 RTU -20 RTU -24 DANFOSS 91-018 (GRAY) DANFOSS 91-018 (GRAY), TYP OF 3 AHU'S iC5 S-35 S-36 S-27 S-26 S-22 S-19 S-15 P S-14 S-13 S-12 S-11 S-10 S-9 S-8 S-17 S-18 TS -3 S-21 S-25 0 U-) i FACTORY MOUNTED I in CO2 CO2 IDS -3 IN RTU TYP RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC RTC AK2 RTC RTC TERMINATOR RTU -35 RTU -36 RTU -27 RTU -26 RTU -22 RTU -19 RTU -15 RTU -14 RTU -13 RTU -12 RTU -11 RTU -10 RTU -9 RTU -8 RTU -17 RTU -18 AHU-3 RTU -21 RTU -25 OUTDOOR SENSOR 2 ASSEMBLY MOUNTING V02LB BOARD ADDRESS #1 Zcn o P # DESCRIPTION 1 SALES LIGHT DIMMING 2 14 13 12 11 10 O P i 01 V S-38 (D o o O =S- 37 I I MOUNT ON`, MOUNT ON •,; s F r�COLUMN _ .,. r� COLUMN WMnut ; ALS RTU38�� RTU37 L� ; E .__ 7f� t EMS: BACKBOARD S-32 ODS - :� .. `� I L EDC1 f _ 29 � 3 n._ F, ;-. L1 JL !!J J , L s L _1 r�TU34 r� 5-30 R��130 I S y --. �LICI 001-3 I gg I RTU321 I I I ! , i 5 �b LJ A ,. L LJ LJ P 3"rLa r....k Wa.... ..h._.1 I RTU33 RTU28 t x RTU 36 ! a # RTU35 5-34 S-33 j j RTU31 ! i i I 4 ppgg f I I.) S 3 :. _ u III INTERFACE RELAY TO I I _ I . t L ° ' MASTER FIXTURE IHi 1 ? RE23BEM1 I �J RTU25 RT_U_24 5-27 3 - i i F i i ? ------ LJ -=�i �r-t �cy�..-� �e-fag .. a 9 _%.-.ffi,...,_. a.._.._....,_ ... _L..S " c ; L__J G ! AHU2 r I RTU26 ( 5-23 E I I RTU �. CO2 5-26 q, -- EM1 � l �� � 5-25 X02 5-24 I E ! RTU ! a � TS -2 I „5 IDS -2 v]; B H AI8 BACKBOARD - E m , R F �M C I RTU21 AHU3 RTU20 1 SALES C I 1 I GROCERY SALES RTU22 d I i I i �1 E. 4 I s t1€ S-22 TS --3 `. DS -3 : AHU1 H ? 4\1! .L i I IEJ E3I s 13 IH O D r� I 9 ..3 '�1 .. r .... «.._S.m...... .,� .g -_..___.y.. .._ ...........n. . ....�,. t...r._ V.. _ .............n. ..., e.._.,.._.. ,.......a._ .°y._.._ _.,... - FRd p RTU18 " RTU17 ; If HH 11 r--1 r -_-i i 4 ahs i__� �_j r--�° C.5 p I RTU19- S-15 P g E` i 1 5-16 3 I i i I � i RTU15u 5-18 T1 _ . , m . _ ht _ a.. r MS I`_._ ! { ! 5-19 ! S 17 CO2 ! ! IDS -1 TS -1 I 3 i y RTU), 1 mHH rrH r -t r� r� .. I I i I 11- s,..� 11 I I RTUS R E i - 3 d y- �•�f«✓`'a.Y9 - t� RTUI 4LJ ``'�' G RTUIOLJ LJ LJr'RTU7 LJ LJ r1 •,«+• „,,.„, S �1 1 S 13 I t `l RTU2 p ! RTU9 RTU8 RTU6 ,m - LJ 3 S 10S S CO2 S-14 r I ' S-11 ( S-7 r, r� �� RTU3�� v i {". i , 14 i yr� 3- -i "w. ✓` Ct&� 'RTI. RTU13 � � 4��.r y S-2 I a S-1 S-8 S -9"m. I(p t' -12 I N _ . j_._ p. 5 3 I m EMS INSTALLER SHALL PROVIDE ADDITIONAL 50'-0" OF EMS -= o CABLE TO ALLOW FOR FUTURE SENSOR INSTALLATION FOR ��� 4 l t EACH RTU SERVING THE TENANT. COORDINATE LOCATION OF SENSOR WITH TENANT CONTRACTOR ail W N io< ppm wF6�0 Va�NW(AQUfJ a wkg ZoJ^ xarz_nam a'=WOF 4�`'wl�yws z 3U20�rc V V V Z was �oa`��'zoaao a Q #N Nzia'��F o3 W a oo��rcws=( Ng (n�oZ bF- on w0wo aa ��Z¢rwnd¢�a� ISSUE BLOCK 01/05/05 C.C.D. #6 02/28/05 C.C.D. #13 03/11/05 C.C.D. #14 CHECKED BY: Zcn o P DRAWN BY: ocduZ-- h V••1 W W FILE NAME: U)WQN4NN PROTO CYCLE: p�WaW ;��wZ DOCUMENT DATE: ��MMO � zXYOI �W\za-N'�'�w O,Z CV (_0a F D fn L ma zFina� J WZx�W Z zw—� 0 Q ISSUE BLOCK 01/05/05 C.C.D. #6 02/28/05 C.C.D. #13 03/11/05 C.C.D. #14 CHECKED BY: DRAWN BY: FILE NAME: EM1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11 /04 V)z�w a K H O CV (_0a F J dWa(it fn L ma zFina� w - � O -az- LLI CL J oaC>z��.i �i O 02 o o uj a V) a Waco z a- z V) a �vViana ISSUE BLOCK 01/05/05 C.C.D. #6 02/28/05 C.C.D. #13 03/11/05 C.C.D. #14 CHECKED BY: DRAWN BY: FILE NAME: EM1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11 /04 Q� O O Z W W 0 0 r o _U N W ofwl7 �ujo N V)z�w a K H r4k Q J dWa(it fn L ma zFina� W v - J H W Lu Ld -az- aw C9 O --azt'.iz CL J oaC>z��.i \i \V 3-QW� mF-Sco0z u uj a V) a Waco z a- z V) a �vViana ENERGY MANAGEMENT PLA SHEET: EM1 6988-600 TO REF 5-REM1 AKC55 LOCATED IN TYP OF 4 ETHERNET CARD EDC1. REF 3 -EMI �- ETHERNET CONNECTION RACK "A" RACK "B" CONTROLLER - - - - - - DANFOSS 91-016 (BLUE) CONTROLLER .* ** DANFOSS 91-016 DANFOSS 91-D16 /� (BLUE), TYP Y_ } �--/ ' (BLUE), TYP 2 TERMINATOR AK2-CM (#4) DANFOSS 91-106 (BLUE) TYP AK2-CM (#4) XM 1010 (#1) R XM 101a (#1) R) f ** ** AI8/DO8 ** AI8 ** AIS ,R FACTORY -WIRED RACK CONTROLLER iR r - - - - - - AK2-CM (#1) XM 205a (#1) XM 101a (#2) XM 101a (#3) RACK MODULES CIRCUIT, TYP RACK CONTROLLER TERMINATOR .,XM. DANFOSS 91-016(BLUE), ** (CONTROLLED FROM R08 IN PSCOMM BOARD ** ** D08 ** D08 ** DOB ** DOB (#3) (AKC55PS) - - - - - - AK2-CM (#2) XM 204a (#1!) XM 204a (#2) XM 204a (#3) XM 204a (#4; (#4) ** XM 101a (#1) 8 XM 101a XM 1010 t_ TERMINATOR XM 101a CABLE FURNISHED WITH I ** ** D08 CABLE TO CH1L PANEL. XM COMPRESSORTERMINATED L AK2-CM (#5) XM 204a (#1) ALARM EL (CONTROLLED FROM R08 IN BY REFRIGERATIIONE, CONTRACTOR -.� XM 101a MODULES AI8 DEFROST PANEL). XM 101a (#3) A18 TERMINATOR XM 101a (#4) XM 101a (#4) DASHED LINE INDICATES XM 101a (#5) FACTORY INSTALLED ** ** D08 AK2-CM (#3) XM 204a (#1) TERMINATOR CONDENSER MODULE ONELINE DIAGRAM AUXILIARY RACK CONTR 5NTS l 6988-600 TO REF 5-REM1 AKC55 LOCATED IN TYP OF 4 ETHERNET CARD EDC1. REF 3 -EMI �- ETHERNET CONNECTION RACK "A" RACK "B" CONTROLLER - - - - - - DANFOSS 91-016 (BLUE) CONTROLLER .* ** DANFOSS 91-016 DANFOSS 91-D16 /� (BLUE), TYP Y_ } �--/ ' (BLUE), TYP 2 TERMINATOR AK2-CM (#4) TERMINATOR AK2-CM (#4) XM 1010 (#1) R XM 101a (#1) R) ** RT-** CASE LIGHTING CONTROL ,R ** iR ** 101a"112•) C -1c CABLE TO CH1L PANEL. XM 101a (#2) .,XM. DANFOSS 91-016(BLUE), ** (CONTROLLED FROM R08 IN TYP C -2b SEivSvR� SENSOR INPUT XM 101a (#3) AI8 DEFROST PANEL). XM 101a (#3) AI8 MODULE TYPICAL (#4) SENSOR XM 101a (#1) 8 XM 101a XM 1010 (#4) XM 101a (#4) XM 101a (#5) CABLE TO CH1L PANEL. XM 101a (#5) DUAL TEMP. SWITCH (TYP DIS XM 101a (#6) )F RACK "A" ONLY - SEE AI8 - A6 SCHEDULE) 4 ON ELI NTS DANFOSS 91-016 (BLUE) TYP - NNW DEFROST PANEL MODULES NOTE: OWNER WILL FURNISH ALL EMS CABLES FOR INSTALLATION BY E.M.C. ** INDICATES DEVICES THAT ARE FACTORY INSTALLED. #5 -101A DASHED LINE INDICATES R ** R T** DESCRIPTION R ** R ** R) ** RT-** DANFOSS 91_016�BLUIE ---MA - - - - - - ,R ** iR ** DEFROST PANEL MODULES NOTE: OWNER WILL FURNISH ALL EMS CABLES FOR INSTALLATION BY E.M.C. ** INDICATES DEVICES THAT ARE FACTORY INSTALLED. TEMP SENSOR (TYPICAL - SEE AI8 SCHEDULES) XM -101A DASHED LINE INDICATES #1 w J D MODEM DESCRIPTION 3 FACTORY WIRING 1 C -1a S 91-016 BLUE RACK "C" CONTROLLER - - DANFOSS 91_016�BLUIE ---MA - - - - - - SENSOR ** 1 3 C -1c SENSOR ** DANFOSS 91-016 4 C -2a DANFOSS 91-016(BLUE), ** i - TYP C -2b SEivSvR� (BLUE), TYP z G 6 TERMINATORAK2-CM SENSOR (#4) TERMINATOR 7 (#4) SENSOR XM 101a (#1) 8 XM 101a (#1) Q O CASE LIGHTING CONTROL XM 101a (#2) CABLE TO CH1L PANEL. XM 101a (#2) (CONTROLLED FROM R08 IN U N Y XM 101a (#3) AI8 DEFROST PANEL). XM 101a (#3) A18 XM 101a (#4) XM 101a (#4) XM 101a (#5) TEMP SENSOR (TYPICAL - SEE AI8 SCHEDULES) AK2 XM -101A (AI8) BD #1 w J D DESCRIPTION DESCRIPTION 3 1 1 C -1a SENSOR O O 1 2 C -lb SENSOR ** 1 3 C -1c SENSOR ** 1 4 C -2a N ** i - 5 C -2b SEivSvR� ** z G 6 C -3a SENSOR ** 1 7 F SENSOR ** 1 8 SPARE SENSOR Q O z 0 U N Y Q AK2 XM -101A (AI8) BD #1 BD DESCRIPTION DESCRIPTION 3 1 1 C -1a SENSOR ** 1 2 C -lb SENSOR ** 1 3 C -1c SENSOR ** 1 4 C -2a SENSOR ** i - 5 C -2b SEivSvR� ** 1 6 C -3a SENSOR ** 1 7 C -3b SENSOR ** 1 8 SPARE SENSOR ** AK2 XM -101A (AI8) BD #2 BD DESCRIPTION DESCRIPTION 3 2 1 C -4a SENSOR ** 2 2 C -4b SENSOR ** 2 3 C-5 SENSOR 3 2 4 C-6 SENSOR 3 2 5 C-7 SENSOR 3 2 6 C -9a SENSOR ** 2 7 C -9b SENSOR ** 2 8 C-10 SENSOR ** AK2 XM -101A (AI8) BD #3 BD DESCRIPTION DESCRIPTION 1 3 1 C -8a SENSOR ** 3 2 C -8b SENSOR ** 3 3 C -8c SENSOR ** 3 4 C -8d S NSOR ** 3 5 C -11a SENSOR ** 3 6 C -11b SENSOR ** 3 7 C -11c SENSOR ** 3 8 SPARE SENSOR ** AK2 XM -101A (AIS) BD #4 BD DESCRIPTION DESCRIPTION 1 4 1 C -13a SENSOR ** 4 2 C -13b SENSOR ** 4 3 C -13c SENSOR ** 4 4 C -14a SENSOR ** 4 5 C -14b SENSOR ** 4 6 C -15o SENSOR ** 4 7 C -15b SENSOR ** 4 8 SPARE SENSOR ** AK2 XM -101A (AI8) BD #5 BD DESCRIPTION DESCRIPTION 1 5 1 C -16a SENSOR ** 5 2 C -16b SENSOR ** 5 3 C -16c SENSOR ** 5 4 C -16d SENSOR ** 5 5 C -17a SENSOR ** 5 6 C -17b SENSOR ** 5 7 SPARE SENSOR ** 5 8 SPARE SENSOR ** 6" E.M AK2 XM -101A (AI8) BD #1 BD DESCRIPTION DESCRIPTION 1 1 D -1a SENSOR ** 1 2 D -1b SENSOR ** 1 3 D-1c(SENSOR).** SENSOR ** 1 4 D -2a SENSOR ** 1 5 D -2b SENSCR ** 1 6 D -2c SENSOR ** 1 7 D -3a SENSOR 6 1 8 D -3b SENSOR 3 AK2 XM -101A (A18) BD #2 BD DESCRIPTION DESCRIPTION 2 1 D -5a SENSOR ** 2 2 D -5b SENSOR ** 2 3 D - 5c SENSOR ** 2 4 D-60 SENSOR ** 2 5 D -6b SENSOR ** 2 6 D -7a SENSOR D -10b 2 7 D -7b (SENSOR) 6 2 8 D-8 SENSOR 3 AK2 XM -101A (AI8) BD #3 BD 4 DESCRIPTION D -4a SENSOR ** 3 1 D -9a SENSOR 4 3 2 D -9b SENSOR 4 3 3 D -9c (SENSOR) SPARE 3 4 D-100 SENSOR ** 3 5 D -10b SENSOR ** 3 6 D-110 SENSOR ** 3 7 D -11b SENSOR ** 3 8 D-12 SENSOR ** AK2 XM -101A (AI8) BD #4 BD oaW�moo� DESCRIPTION 4 1 D -4a SENSOR ** 4 4 2 3 -4 O ** SPARE 4 4 ARE 4 5 S A E 4 6 SPARE 4 7 SPARE 4 8 SPARE PROVIDE JUNCTION BOX FOR CONTROLS OF FAN COIL 1/2" PENETRATION THRU ROOF FOR SENSOR LEADS AND SEAL INSIDE AND OUT WITH SILICONE OR EXPANDING FOAM AND SEALANT RETURN AIR TEMP SENSOR CEILING OF BOX SINGLE COIL EVAPORATOR NOTE: OWNER WILL FURNISH ALL EMS CABLES FOR INSTALLATION BY E.M.C. ** INDICATES DEVICES THAT ARE FACTORY INSTALLED. PROVIDE P3300 UNISTRUT OR EQUAL. SECURE UNISTRUT TO STRUCTURE AND TOP OF COOLER. PROVIDE CROSS -BRACING AS REQUIRED TYP -� 120V FROM COMP- RESSOR HOUSE #1 PROVIDE 4"X4" WIREWAY TYP PROVIDE DUAL TEMPERATURE SWITCH AT BOTTOM OF CIM. REF CIM SCHEDULES FOR QUANTITY TYP - TEMPERATURE SENSO L NTS 08.29.03 "LTA" "LTB" COOLER FREEZER -7 AI8 BA NTS Will _._...... �•- -. , �. .._..�., � �—....`._:_ it D -9c D 9b D 90 LFA_.-. amu. ,i ,r i' �� I j —.. "I I A-13 II - - __. I 0 E; ICE CREAM -IL���u -1L �I FREEZER �' DAIRY �I �} — s s cool, 1 ,s D-1 1b' "¢" D -10a (� C�� T�� _ I I I I(._ :��`� A -7b l V B -5a GROCERY I' I�B -13a I i I `t�.._;� t• �I ' - j II 0 III !t A -10a 1 t (} A -11c 9 S S t w L�.i_.,_'. D-4a<D-4b 4f - P hI I I COMPRESSOR HOUSE #2 M -H i ;f ;yds Q RACK D CONTROLLER SWEATMISER TEMP/HUMIDITY SENSOR(S) M -T t i Is f I r yf C- i 40 l f 1 3 t I I " RACK C CONTROLLER BACKBOARD /;\ REF 3-REM1 I GROCERY SALES i D -3b 1I L� <_C -3-c S I DEA -T-AND_ _ _ _ is F LI COOLER ' 1, O- s C -13b S ICOMPRESSOR HOUSE #1 t 1(-i �s .•,i .r -,• - TEMP SENSOR FOR REFRIGERATED � j # RACK B CONTROLLER CASE. FACTORY INSTALLED C -13a ✓ d �I PROVIDE 2" CONDUITS ; TYPICAL REF &; SCHEDULES TO JOIST LEVEL AS l s SEAFOOD NEEDED FOR CABLING FREEZER AND PROVIDE BUSHINGS s AT EACH END TYP--� B -3b Is RACK A CONTROLLER 120V FROM COMP- /- '' ;f X RESSOR HOUSE #2 I B-4 O E _.-- - _-__-_� - --- - v--- =2a �- --- - _ �l I -� ------ i S` A -la AN n•s ue €€ "MTC S C -1b K AS AS AS A8 .._ I I W" A(2 -cu m, tat tat tm "MTD" to S� 3e.. �`- PROVIDE PLYWOOD BACKBOARD TOP OF COOLER/ ( ! FREEZER WALL t A -3b S Ss A -3a ' I C -17b S IA -4b D DETAIL ; PROVIDE JUNCTION BOX FOR CONTROLS OF FAN COIL 1/2" PENETRATION THRU ROOF FOR SENSOR LEADS AND SEAL INSIDE AND OUT WITH SILICONE OR EXPANDING FOAM AND SEALANT CEILING OF BOX SECURE SENSING ELEMENT AND CABLE WITH (2) NYLON MOUNTING BRACKETS (PANDUIT #PP2S-S10-X) AT RIGHT ANGLES TO EACH OTHER. PLACE BULB APPROX 3" OFF CENTER IN MAXIMUM RETURN AIR STREAM. MOUNT BRACKET WITH EXISTING FAN SHROUD MOUNTING SCREW. DO NOT DRILL HOLE IN DRAIN PAN TO MOUNT BRACKETS. CABLE TO EXTEND TO COIL ON HINGED SIDE OF DRAIN PAN. DUAL COIL EVAPORATOR ATION Cl REFRIGERATION ENERGY ti- -TEMP SENSOR FOR DUAL COIL EVAPORATOR. FIELD INSTALLED TYP REF 2-REM1 TEMP SENSOR FOR SINGLE COIL EVAPORATOR. FIELD INSTALLED TYP REF 2-REM1 MANAGEMENT PLAN wdor in 9 WI -V � 4zQ¢ =)Z^��QOw�twZy/tt ZNF UJ 84gb�ppoaw¢¢N�Wo p'' w��ZCO pJppp �^NXOyytZNy¢m Z Q" < W O O a W LLly i 0 30 py ow,ww000 08! 51ST' z,ya. odnozoza J Q< �N=FS,� '� 'S CL cp PtI:v'J--NPoAF N W pD FG K O¢ U a 7 F V7 �= aQ Je<m<x KQ� ISSUE BLOCK zfj,Qp 11/17/04 oaW�moo� 28 01/24/05 C.C.D. #8 aCwm; ncz �I.E3 02/28/05 wzo,—F— z Gi <C ""z C.C.D. #17 ZOO ZOOWxW�= <00 J dwCW wz���� N � o XWE��w " J v ISSUE BLOCK '-- 11/17/04 C.C.D. #2 28 01/24/05 C.C.D. #8 f � \ 02/28/05 C. C. D. #13 Q 05/04/05 C.C.D. #17 <00 �k J dwCW w _N 2ww �ma� J <lw w wam w¢w ~a0zo C W O W W Pn_< ,z_ ZZMLJ UQ wflnn 3o0w< rn w CHECKED BY: '-- DRAWN BY: FILE NAME: REM1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 OV zw w FO UrmO V �w "_ 0 rnD Jwie <00 �k J dwCW w _N 2ww �ma� J <lw w wam w¢w ~a0zo C W O W W Pn_< ,z_ ZZMLJ UQ wflnn 3o0w< rn w w =wSof;�rx S2 REFRIG ENERGY MANAGEMENT PLAN SHEET: REM1 TYPICAL REFRIGERATED CASE SYSTEM 5 DOOR CASE 5 DOOR CASE 4 DOOR CASE 12.6 A j 12.6 A 9.9 A A B B C A I C I 1 PROVIDE 208/3o HOME RUN TO PRE—WIRED PANEL IN COMPRESSOR HOUSE. FINAL CONNECTION AT EACH END BY REC NOTE: ON SYSTEMS WITH UNEQUAL LOADS, REC (REFRIGERATION ELECTRICAL CONTRACTOR) SHALL ARRANGE CONNECTIONS FOR MAXIMUM BALANCE OLOAD CALCULATED UNBALANCED 3 AO LOAD = (12.6 A + 9.9 A) x .866 = 19.5 A BO LOAD = (12.6 A + 12.6 A) x .866 = 21.8 A (HIGH LEG) CO LOAD = (12.6 A + 9.9 A) x .866 = 19.5 A -----------------------------------.--- '1.�-----___------ REF 1-RE1.1 REF 1-RE1.1 i MEAT AND 12 i DELI COOLER I COMPRESSOR �« D-3 CFJ HOUSE #1 ED E 1 I DEFROST TERMINATION 4IREWAY RACK B SEAFOOD m I FREEZER B 2 < A4 MSB3 480V MAIN PANEL 10 150 kVA XFMR Co CH2 1 AUXILIARY PANEL 5 w 19 iCH1L L4D" +72" CH1F -4 J 16.706 208V DIST. PANEL ~-- a J UTILITY PANEL "CH1L" PANEL "CH1F" I 16.701 PANEL "CH1A" CH1F-22 = — „SWEATMISER" PANEL g j CH1 L-6 a ---"CH" PANEL WIREWAY 4V/""�JL VI_I 1\V�J I rill\IMV NTS 05.25.01 ER 03 CONDUITS FOR REFRIGERATED CASE SYSTEM. CONDUIT(S) WILL SERVE 120V CASE FAN, CASE LIGHT AND CASE ANTI -SWEAT CIRCUITS, IN ADDITION, CONDUIT(S) WILL SERVE 208V CASE ELECTRIC DEFROST CIRCUIT (IF APPLICABLE). NOTE: CIRCUITS MAY BE GROUPED TOGETHER TO MINIMIZE NUMBER OF CONDUITS PROVIDED THAT ALL NEC REQUIREMENTS ARE MET PROVIDE 5' LENGTH OF LIQUID -TIGHT FLEXIBLE METAL CONDUIT. FURNISH APPROXIMATELY 12" PIGTAIL STUBBED FROM END OF EACH FLEX CONDUIT FOR TERMINATION TO REFRIGERATED CASE ELECTRICAL CONNECTION POINT BY R.C. PROVIDE TRANSITION FROM PVC TO EMT TYPICAL REFRIGERATED CASE SYSTEM ROUTE EMT CONDUITS (UNDER CASES, ABOVE SLAB) TO POINT OF TRANSITION TO FLEX 12" WIRE PIGTAILS TYP — -� 5' FLEX CONDUIT TYP FLOOR BRACKET CONDUIT TO FLOOR AS REQUIRED PER CODE TYP PROVIDE TRANSITION FROM EMT TO FLEX REFRIGERATION PIT UNDERSLAB PVC CONDUIT FOR REFRIGERATED CASE BRANCH CIRCUITS CASE CONNECTION WIRING L 3 NTS 07.25.03 ER02 NOTE: TAP DEFROST CIRCUIT IN CONDULET AT CEILING PENETRATION DEFROSI FEWER SCHEDULE JUNCTION BOX WITH #10 AWG FOR FILLED WITH SEALANT CONDUIT CONNECTION TO UNIT. MAXIMUM DOCUMENT DATE: CONDUIT PENETRATION LENGTH OF TAP CONDUCTOR 18" CONDUIT AND WIRING TO PRE -WIRED SEALED WITH SILICONE I�. ~6:x Ymmz PANEL IN COMPRESSOR HOUSE SEALANT CONDUCTORS FINAL CONNECTION TO PRE -WIRED a�¢W WIRE PANEL BY RC CONDUIT AND WIRING TO NEXT U COOLER/FREEZER BOX CEILING JUNCTION BOX ON SAME SYSTEM - 1/2" (2) #12 (WHERE SHOWN ON DRAWINGS) ,¢�zr¢ CEILING MOUNTED WP JUNCTION BOX NOTE: CONDUIT AND WIRING SAME E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN COMPRESSOR HOUSE. WITH THREADED HUBS AND GASKETED SIZE AND QUANTITY AS WIRING U �ZO�m COVERPLATE TO PRE -WIRED PANEL (UNO) (1) #10 W w w W W PROVIDE CEILING MOUNTED MANUAL SWITCH - P _ (NEMA 4) 'SQUARE D' TYPE K, CLASS 2510 TYPICAL COIL FINAL TERMINATIONS AT CASE AND IN COMPRESSOR HOUSE BY R.C. REF DETAILS 3-RE1 AND 4-RE1. 4 OR EQUAL FOR CONNECTION OF EVAPORATOR 1/2" COIL FANS (CF) AND/OR DEFROST (ED), I i i (WHERE SHOWN ON DRAWINGS) 1/2" (3) #12 LIQUID TIGHT FLEX CONDUIT TO -- ' KNOCKOUT ON UNIT. FINAL -- - - ---- — -- CONNECTION TO COIL BY RC NOTE: DO NOT LOCATE WP JUNCTION BOX DIRECTLY IN FRONT OF DISCHARGE FAN, OFFSET TO SIDE. (3) #8 Z L NTS 05.25.01 ER01 16.702 Y --- J < SURFACE MOUNT BOX ON I RACK. ROU -TE 3/4" CONDUIT �TO BAR JQIST IN GROCERY B-4 TO FOR VOICE LINE oil I CH2L-1 FOR REFRIGERATION EMS. A-2 VERIFY EXACT ` � _ � CH2F-1 LOCATION WITH _� _..._.,___.�-_. .. _.� _.._ EMS CONTRACTOR. r r "• 16.710 _ s A-1 1g 709 DEFROST TERMINATIO N 2 5 r ? xU -------------a WIREWAY RACK A 1 rt€iI4 GROCERY SALES 2 (A-2) —a s IC -1 : NOTE: ','.£i PANELS AND XFMRS PROVIDED N = �Is� WITH HOUSE. REF "R" SHEETS SII qE FOR PANEL DESIGNATIONS N 13 U- m !r 3 NOTE: -i [PROVIDED ATER HEATER HEAT TRACE TAPE SHALL BE FED FROM 120 VOLT RECEPTACLE. RECEPTACLE 13.1 WITH COMPRESSOR HOUSE. �"ia :_�_.-�_�-__<_��__—.D�.—�--._�_2 ...._�.—�Iip.�_. L.�_._._____._..�_____._4_._._.__�. .6__Di..._-7�N.1_ 1i►+6 m Wi. m . _ N1I 6 1 Lo 29 Ll _ .._.-04N [V N r J CH1F-27.29+U U 6 EFRIGERATED CASE ELiECTRICAL C-3 CONNECTION POINT; TYPTYP TYPF_ C �1ii'o�I _ I Si? — 4 10 T —C N.___NT.. �_T..w_.��_...._..._..._____._.,.__xUw._.._.xU._�_—___..«_ ,_�_�__.1_.F ' CN J i4 16.710 s i �y — 51 I I' s TERMINATE ii 16'708 I—► v CAKE DECORATING = _ CONDUITS 12' sy TYP SERVICE DELI U ABOVE CHASEIF- ,4 BAKERY cs O -I 0 CH2L-3t CH2F-3 ... .. _ _.._._.o A-4 a III' CH2L-5 j CH2F 5 g 4' 1 � t F IPRODUCE PREP CH1A-2 CH1L-2 ° CH1F-2 +72" C 12F 9 16 709 . CF J 0 o-__._ _._ _l 15 J o BAKERY DELI o L -t tea w 0 15 / w 0 � CH2F 11 a J FREEZER J C-7 I POULTRY COOLER T _ .__. _ _____. BAKERY COOLER 0 i 0 0 0 W N o< Opp N ouwi<ZzwoLLz< LL Z-]�Qo F_ - ZNZ <<a 02 woW+w O Z a$svizoo Rz aowo 0 no xO3aomoogwo < Fm P_- <NU6N J mw IKM00NZ€1�F N059w'mb_ aoawap REFRIGERATED CASE ELECTRIC DEFROSI FEWER SCHEDULE NO. RE1 CONDUIT NUMBER AND SIZE OF DOCUMENT DATE: Oo� EQ. GROUND � WzaoN�,�,w NOTES I�. ~6:x Ymmz Q SIZE CONDUCTORS a�¢W WIRE 0 O U 0 LLJ 1/2" (2) #12 ,¢�zr¢ (1) #12 O O LwX W F Z W E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN COMPRESSOR HOUSE. J 21 U �ZO�m 1/2" (2) #10 (1) #10 W w w W W U) zv0iaacna- 0 FINAL TERMINATIONS AT CASE AND IN COMPRESSOR HOUSE BY R.C. REF DETAILS 3-RE1 AND 4-RE1. 3 1/2" (2) #8 (1) #8 4 1/2" (3) #12 (1) #12 F5 1/2p, (3) #10 (1) #10 © 3/4" (3) #8 (1) #10 0 3/4„ (3) #8 (1) #8 ® 3/4,. (3) #6 (1) #10 ❑9 3/4„ (3) #6 1 (1) #8 WALK—IN UNIT COOLER FEEDER SCHEDULE NO. CONDUIT COIL FANS ELECTRIC DEFROST EQ. GROUND NOTES SIZE (CF) (ED) WIRE 10 _ 3/4" (2) #12 (2) #12.. (1) #12_. E.C. SHALL PROVIDE CONDUIT AND WIRE FOR EVAP. COIL FAN (CF) AND 11 3/4" (2) #12 (2) #8 (1) #8 ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR HOUSE. 12 3/4" (2) #12 (2) #6 (1) TERMINATIONS AT COIL AND IN COMPRESSOR HOUSE BY R.C. #10 RIFNAL F TAIL 2-RE1. 13 3/4" (2) #12 (3) #10 (1) #10 14 3/4" (2) #12 (3) #8 (1) #10 5 1" (2) #10 (3) #8 (1) #8 16.702 Y --- J < SURFACE MOUNT BOX ON I RACK. ROU -TE 3/4" CONDUIT �TO BAR JQIST IN GROCERY B-4 TO FOR VOICE LINE oil I CH2L-1 FOR REFRIGERATION EMS. A-2 VERIFY EXACT ` � _ � CH2F-1 LOCATION WITH _� _..._.,___.�-_. .. _.� _.._ EMS CONTRACTOR. r r "• 16.710 _ s A-1 1g 709 DEFROST TERMINATIO N 2 5 r ? xU -------------a WIREWAY RACK A 1 rt€iI4 GROCERY SALES 2 (A-2) —a s IC -1 : NOTE: ','.£i PANELS AND XFMRS PROVIDED N = �Is� WITH HOUSE. REF "R" SHEETS SII qE FOR PANEL DESIGNATIONS N 13 U- m !r 3 NOTE: -i [PROVIDED ATER HEATER HEAT TRACE TAPE SHALL BE FED FROM 120 VOLT RECEPTACLE. RECEPTACLE 13.1 WITH COMPRESSOR HOUSE. �"ia :_�_.-�_�-__<_��__—.D�.—�--._�_2 ...._�.—�Iip.�_. L.�_._._____._..�_____._4_._._.__�. .6__Di..._-7�N.1_ 1i►+6 m Wi. m . _ N1I 6 1 Lo 29 Ll _ .._.-04N [V N r J CH1F-27.29+U U 6 EFRIGERATED CASE ELiECTRICAL C-3 CONNECTION POINT; TYPTYP TYPF_ C �1ii'o�I _ I Si? — 4 10 T —C N.___NT.. �_T..w_.��_...._..._..._____._.,.__xUw._.._.xU._�_—___..«_ ,_�_�__.1_.F ' CN J i4 16.710 s i �y — 51 I I' s TERMINATE ii 16'708 I—► v CAKE DECORATING = _ CONDUITS 12' sy TYP SERVICE DELI U ABOVE CHASEIF- ,4 BAKERY cs O -I 0 CH2L-3t CH2F-3 ... .. _ _.._._.o A-4 a III' CH2L-5 j CH2F 5 g 4' 1 � t F IPRODUCE PREP CH1A-2 CH1L-2 ° CH1F-2 +72" C 12F 9 16 709 . CF J 0 o-__._ _._ _l 15 J o BAKERY DELI o L -t tea w 0 15 / w 0 � CH2F 11 a J FREEZER J C-7 I POULTRY COOLER T _ .__. _ _____. BAKERY COOLER 0 i 0 0 0 W N o< Opp N ouwi<ZzwoLLz< LL Z-]�Qo F_ - ZNZ <<a 02 woW+w O Z a$svizoo Rz aowo 0 no xO3aomoogwo < Fm P_- <NU6N J mw IKM00NZ€1�F N059w'mb_ aoawap zc, 0 DRAWN BY: ow'- N WWF W FILE NAME: RE1 PROTO CYCLE: T2 DOCUMENT DATE: Oo� W ui � WzaoN�,�,w � Z I�. ~6:x Ymmz Q z -Q ;.W_ OWKW< J 2 (A-2) —a s IC -1 : NOTE: ','.£i PANELS AND XFMRS PROVIDED N = �Is� WITH HOUSE. REF "R" SHEETS SII qE FOR PANEL DESIGNATIONS N 13 U- m !r 3 NOTE: -i [PROVIDED ATER HEATER HEAT TRACE TAPE SHALL BE FED FROM 120 VOLT RECEPTACLE. RECEPTACLE 13.1 WITH COMPRESSOR HOUSE. �"ia :_�_.-�_�-__<_��__—.D�.—�--._�_2 ...._�.—�Iip.�_. L.�_._._____._..�_____._4_._._.__�. .6__Di..._-7�N.1_ 1i►+6 m Wi. m . _ N1I 6 1 Lo 29 Ll _ .._.-04N [V N r J CH1F-27.29+U U 6 EFRIGERATED CASE ELiECTRICAL C-3 CONNECTION POINT; TYPTYP TYPF_ C �1ii'o�I _ I Si? — 4 10 T —C N.___NT.. �_T..w_.��_...._..._..._____._.,.__xUw._.._.xU._�_—___..«_ ,_�_�__.1_.F ' CN J i4 16.710 s i �y — 51 I I' s TERMINATE ii 16'708 I—► v CAKE DECORATING = _ CONDUITS 12' sy TYP SERVICE DELI U ABOVE CHASEIF- ,4 BAKERY cs O -I 0 CH2L-3t CH2F-3 ... .. _ _.._._.o A-4 a III' CH2L-5 j CH2F 5 g 4' 1 � t F IPRODUCE PREP CH1A-2 CH1L-2 ° CH1F-2 +72" C 12F 9 16 709 . CF J 0 o-__._ _._ _l 15 J o BAKERY DELI o L -t tea w 0 15 / w 0 � CH2F 11 a J FREEZER J C-7 I POULTRY COOLER T _ .__. _ _____. BAKERY COOLER 0 i 0 0 0 W N o< Opp N ouwi<ZzwoLLz< LL Z-]�Qo F_ - ZNZ <<a 02 woW+w O Z a$svizoo Rz aowo 0 no xO3aomoogwo < Fm P_- <NU6N J mw IKM00NZ€1�F N059w'mb_ aoawap ISSUE BLOCK 11/17/04 C.C.D. #2 01/24/05 C.C.D. #8 Ak 02/28/05 C.C.D. #13 CHECKED BY: zc, 0 DRAWN BY: ow'- N WWF W FILE NAME: RE1 PROTO CYCLE: T2 DOCUMENT DATE: Oo� W ui � WzaoN�,�,w � Z I�. ~6:x Ymmz Q z -Q ;.W_ OWKW< J a�¢W wzzwwFLL w zr� 0 O U 0 ISSUE BLOCK 11/17/04 C.C.D. #2 01/24/05 C.C.D. #8 Ak 02/28/05 C.C.D. #13 CHECKED BY: DRAWN BY: FILE NAME: RE1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 W ui a.ozzi5< ig Q co 0 J a�¢W W (n N m O r O r m Q z 0 LLJ Z ~�W ,¢�zr¢ CCD O O LwX W F Z W \ J U �ZO�m LJ msv Oz �of � W w w W W U) ISSUE BLOCK 11/17/04 C.C.D. #2 01/24/05 C.C.D. #8 Ak 02/28/05 C.C.D. #13 CHECKED BY: DRAWN BY: FILE NAME: RE1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 O U Z W W 00 vrLod (n0 U W W ui a.ozzi5< ig J W ao0op J a�¢W W (n N m O r Z r m Q z 0 J ~�W ,¢�zr¢ O O LwX W F Z W \ J U �ZO�m LJ msv Oz �of � W w w W W U) zv0iaacna- 0 REFRIG ELECTRICAL M SHEET: RE1 PANELBOARD CH1A BOARD PANEL NCH CIRCUITS CONTROLLED BY FACTORY- INSTALLED208/12OV, 3 PH, 4W - 225A M. L. 0. SERVES: REFRIGERATED CASE ANTI SWEAT HEATERS CYCLED , LOCATION: COMPRESSOR HOUSE #1 10,000 AIC PANEL PROVIDED WITH COMPRESSOR HOUSE GROUND BUS SURFACE MOUNT CONDUIT DESCRIPTION WIRE BRKRIPK L FACTORY PROVIDED PL BRKR WIRE DESCRIPTION CONDUCTORS i D8�ROST TERMINATION 208/12OV, 3 PH, 4W SERVES: REFRIGERATED CASE LIGHTS PL 20 1 .. B 1 20 225A, M. L. 0. LOCATION: COMPRESSOR HOUSE #1 3 1 A-10 CASE A/S HTRS (6) #10 20 1 1.32 0.36 1 1 20 B-3 CASE FANS B-1 CASE A/S HTRS 2 3 A-11 CASE A/S HTRS (6) #8 20 1 1 1.32 0.84 1 20 IB B-3 CASE A/S HTRS 4 5 A-12 CASE A/S HTRS 6 8 20 1 1 1.81 1.82 1 20 #8 -5 CASE A/S HTRS 6 6 7 SPACE 20 1 1 1.15 1.08 1 1.20 1 20 #10 B-6 CASE A/S HTRS (6) 8 9 SPACE WIRE 1 DESCRIPTION 0.96 1 20 #10 B-6 CASE A/S HTRS (6) 10 11 SPACE 20 1 B 1.20 1 20 #8 B-7 CASE A/S HTRS 6 12 13 SPACE 20 1 A-10 CASE LIGHTS 0.96 1 20 #10 B-7 CASE A/S HTRS (6) 14 15 SPACE 20 B-1 CASE i82 1 20 #6 B-8 CASE A/S HTRS (6) 16 17 SPACE 0.81 0.52 1 1 1.82 1 20 #6 B-9 CASE A/S HTRS 6 18 19 SPACE #10 20 1 1.20 1 20 #8 B-10 CASE A/S HTRS (6) 20 21 SPACE LIGHTS 6 7 0.96 1 20 #10 B-10 CASE A/S HTRS (6) 22 23 SPACE 20 #10 B-5 1 1.20 1 20 #10 B-11 CASE A/S HTRS (6) 24 25 SPACE 20 1 1.28 0.18 0.18 0.96 1 20 #10 B-11 CASE A/S HTRS (6) 26 27 SPARE SPARE 1 20 1.82 1 20 #8 B-12 CASE A/S HTRS (6) 28 29 SPARE CASE LIGHTS 6 12 13 1 20 REF EMS BOARDS SPARE 30 31 SPACE 1 20 #10 B-8 CASE LIGHTS (6) 14 SPACE 32 33 SPACE 20 1 1.10 1 1 20 #10 SPACE 34 35 SPACE 17 SPACE 0.18 1 1 0.55 1 1 1 SPACE 36 37 SPACE B-10 CASE LIGHTS 6 18 19 SPACE SPACE SPACE 38 39 SPACE 20 1 20 #10 B-11 CASE LIGHTS (6) SPACE 40 41 SPACE 55 55 AMPS TOTAL LOAD 19.96 KVA 55 AMPS 1.10 KVA 55 AMPS 1 20 SPACE 42 TOTAL 6.01 7.73 7.86 KVA PER NEC ARTICLE 220 50 64 66 AMPS TOTAL LOAD AMPS 21.60 KVA 60 60 FEEDER LOAD 21.60 KVA AMPS TOTAL CH1L 208/12OV, 3 PH, 4W PANELBOARD LOCATION: COMPRESSOR HOUSE #1 10,000'AIC PANEL PROVIDED WITH COMPRESSOR HOUSE GROUND BUS SURFACE MOUNT CONDUIT DESCRIPTION WIRE BRK PANEL CONTROLLED VIA 10OA-3P FACTORY PROVIDED CONTACTOR RK WIRE DESCRIPTION CONDUCTORS i D8�ROST TERMINATION 208/12OV, 3 PH, 4W SERVES: REFRIGERATED CASE LIGHTS PL 20 1 0.58 0.18 1 20 225A, M. L. 0. LOCATION: COMPRESSOR HOUSE #1 3 A-2 FANS & A/S HTRS LOCATION: COMPRESSOR HOUSE #2 20 1 1 0.55 0.42 10,000 AIC PANEL PROVIDED WITH COMPRESSOR HOUSE B-3 CASE FANS 4 5 A-3 FANS & A/S HTRS 6 8 20 GROUND BUS 1 1.44 1 0.90 1 20 #10 B-5 CASE FANS 6 7 A-4 FANS & A/S HTRS SURFACE MOUNT 20 1 0.55 1.08 1 20 #10 A 8 9 A-6 FANS & A/S HTRS (6) #6 20 1 1 1.15 1.08 1 1 20 DESCRIPTION WIRE BRKR PL PL BRKR WIRE 1 DESCRIPTION 1 20 #10 B-8 CASE FANS 6 12 13 A-8 FANS & A/S HTRS (6) #6 20 1 B 1 C #10 B-9 CASE FANS (6) 14 15 A-9 FANS & A/S HTRS (6) #10 20 1 A-10 CASE LIGHTS 1 20 1 0.81 0.23 17 1 20 20 B-1 CASE LIGHTS 2 3 A-11 CASE LIGHTS (6) #10 20 1 #10 0.81 0.52 1 1 20 20 B-3 CASE LIGHTS 4 5 A-12 CASE LIGHTS 6 #10 20 1 1 1 1.05 0.21 1 20 23 B-4 CASE LIGHTS 6 7 SPARE 20 20 1 24 1.10 A-2 CASE RECEPTACLE 1 20 #10 B-5 CASE LIGHTS (6) 8 9 SPARE 27 20 1 20 1 1.28 0.18 0.18 1 20 #10 B-6 CASE LIGHTS (6) 10 11 SPARE 1 20 Ill 20 1 1.28 11 20 #8 B-7 CASE LIGHTS 6 12 13 SPACE REF EMS BOARDS 32 33 1.10 1 1 20 #10 B-8 CASE LIGHTS (6) 14 15 SPACE A-9 CASE RECEPTACLE 1 20 1 1.10 1 1 20 #10 B-9 CASE LIGHTS (6) 16 17 SPACE 0.18 1 1 0.55 1 1 1 1.28 1 20 #8 B-10 CASE LIGHTS 6 18 19 SPACE SPACE 40 41 A-11 CASE RECEPTACLE 1.28 1 20 1 20 #10 B-11 CASE LIGHTS (6) 20 21 SPACE PER NEC ARTICLE 220 56 55 55 AMPS TOTAL LOAD 19.96 KVA 55 AMPS 1.10 KVA 55 AMPS 1 20 #10 B-12 CASE LIGHTS (6) 22 23 SPACE 4 � - SPACE 42 TOTAL 7.97 1 20 PER NEC ARTICLE 220 66 SPARE 56 AMPS 24 66 AMPS TOTAL FEEDER LOADI 23.69 4.53 4.82 3.81 KVA \ (2) INSTALL LOCKING DEVICE FURNISHED WITH PER NEC ARTICLE 220 AMPS PANELBOARD (LOCK -OFF FOR MAINTENANCE). - 38 40 1 32 TOTAL LOAD AMPS 13.17 KVA 37 16.46 46 FEEDER LOADr KVA AMPS CH1 F PANELBOARD 208/12OV, 3 PH, 4W SERVES: REFRIGERATED CASE FANS, OUTLETS & A/S HTRS (NON -CYCLED) 225A, M. L. 0. LOCATION: COMPRESSOR HOUSE #1 10,000'AIC PANEL PROVIDED WITH COMPRESSOR HOUSE GROUND BUS SURFACE MOUNT CONDUIT DESCRIPTION WIRE BRK PL A PL RK WIRE DESCRIPTION CONDUCTORS i D8�ROST TERMINATION DESCRIPTION 1 A-1 FANS & A/S HTRS PL 20 1 0.58 0.18 1 20 , I { I -i I B-1 CASE FANS 2 3 A-2 FANS & A/S HTRS LOCATION: COMPRESSOR HOUSE #2 20 1 1 0.55 0.42 1 20 CO!PUNE'C'nON BY CONTRACTOR TYPBCAL. B-3 CASE FANS 4 5 A-3 FANS & A/S HTRS 6 8 20 1 1 1.44 1 0.90 1 20 #10 B-5 CASE FANS 6 7 A-4 FANS & A/S HTRS #10 20 1 0.55 1.08 1 20 #10 B-6 CASE FANS (6) 8 9 A-6 FANS & A/S HTRS (6) #6 20 1 1 1.15 1.08 1 1 20 #10 B-7 CASE FANS (6) 10 11,A-7 FANS & A/S HTRS 6 10 20 1 1 0.55 1 0.90 1 20 #10 B-8 CASE FANS 6 12 13 A-8 FANS & A/S HTRS (6) #6 20 1 1.15 1 0.90 1 1 20 #10 B-9 CASE FANS (6) 14 15 A-9 FANS & A/S HTRS (6) #10 20 1 0.55 1.08 1 20 #10 B-10 CASE FANS (6) 16 17 A-10 CASE FANS ELECTRIC DEFROST 20 1 1 0.66 1 1.08 1 20 #10 B-11 CASE FANS 6 18 19 A-11 CASE FANS (6) #10 20 1 0.66 1 0.90 1 20 #6 B-12 CASE FANS 20 21 A-12 CASE FANS (6) #10 20 1 1 0.90 0.12 1 20 10 B-4 CASE FANS 22 23 A-2 CASE RECEPTACLE 1 20 fl 1 0.18 1 0.18 1 20 #10 B-5 CASE RECEPTACLE 24 25 A-2 CASE RECEPTACLE #8 20 1 0.18 1 0.18 1 20B-8 D-10 CASE CASE RECEPTACLE 26 27 A-4 CASE RECEPTACLE 20 1 0.18 0.18 1 20 #10 113 9 CASE RECEPTACLE 28 29 A-4 CASE RECEPTACLE 12 20 1 0.18 0.18 1 20 1 1 B-12 _CASE RECEPTACLE 30 31 A-7 CASE RECEPTACLE #8 20 1 0.18 0.05 1 20 REF EMS BOARDS 32 33 A-7 CASE RECEPTACLE 1 20 1 1 0.18 1 20 19 SPARE ""' 34 35 A-9 CASE RECEPTACLE 1 20 1 0.18 1 20 SPA E SPARE 36 37 A-9 CASE RECEPTACLE 20 1 0.18 1 1 0.55 1 1 SPACE 38 39 A-10 CASE RECEPTACLE 1 20 1 1 0.18 20 1 SPACE 40 41 A-11 CASE RECEPTACLE 20 1 0.18 ARE NOT ADJACENT TO WALLS TO BE ROUTED TOTAL 4.69 SPACE 42 TOTAL 6.77 6.58 6.61 KVA PER NEC ARTICLE 220 56 55 55 AMPS TOTAL LOAD 19.96 KVA 55 AMPS FEEDER LOADI 19.96 KVA 55 AMPS CH2F PANELBOARD 208/12OV, 3 PH, 4W SERVES: REFRIGERATED CASE FANS, RECEPTACLES & A/S HTRS (NON -CYCLED) 225A, M. L 0. LOCATION: COMPRESSOR HOUSE #2 10,000 AIC PANEL PROVIDED WITH COMPRESSOR HOUSE GROUND BUS SURFACE MOUNT CONDUIT HOUSE #2 SYSTEM IN COMPRESSOR HOUSE. ROUTE °z EQ. GROUND A PROVIDED CONTACTOR' o C-15 !� CONDUCTORS i D8�ROST TERMINATION DESCRIPTION WIRE BRKR PL PLBRKR STRUCTURAL STEEL IN MAIN BUILDING. WIRE DESCRIPTION (2) #12 , I { I -i I 16.708 DUPLEX RECEPTACLE FURNISHED WITH (1) #12 225A, M. L. 0. LOCATION: COMPRESSOR HOUSE #2 REFRIGERATED CASE. FINAL ELECTRICAL A B C (2) #10 I 1 i CO!PUNE'C'nON BY CONTRACTOR TYPBCAL. 10,000 1 C-1 CASE FANS (6) #10 20 1 1.38 0.65 1 20 #10 D-1 CASE FANS (6) 2 3 C-2 CASE FANS (6) #10 20 1 1 1.00 1 0.65 1 20 #10 D-2 CASE FANS (6) 4 5 C-3 CASE FANS 6 10 20 1 1 1.00 1 0.60 1 20 RK D-5 CASE FANS 6 7 C-4 CASE FANS 20 1 0.32 0.48 1 20 D-6 CASE FANS 8 9 C-5 COIL FANS (6) #8 20 1 1 1.01 1 1.51 1 20 #8 D-7 COIL FANS (6) 10 11 C-6 COIL FANS 6 10 20 1 1 0.50 1 1.51 1 20 1 #8 D-8 COIL FANS 6 12 13 SPARE ELECTRIC DEFROST 20 1 1.51 1 20 #8 D-7 COIL FANS (6) 14 15 C-8 FANS & A/S HTRS (6) #6. 20 1 1.11 1.51 1 20 #6 D-9 COIL FANS (6) 16 17 C-9 CASE FANS (6 8 20 1 0.70 0.60 1 20 10 D-10 CASE FANS 6 18 19 C-10 FANS & A/S HETRS 1 20 1 0.18 0.541 LIGHTS 20 #10 D-11 CASE FANS (6) 20 21 C-11 CASE _FANS (6) #8 20 1 0.82 0.24 1 20 D-10 CASE D-12 CASE FANS 22 23 SPARE 20 1 1 1.24 1 20 #10 DAIRY COOLER DOOR HTRS 6 24 25 C=13 CASE FANS 12 20 1 0.72 1 0.38 1 1 20 1 1 -4 CASE FANS 26 27 C-14 CASE FANS #8 20 1 0.48 0.05 1 20 REF EMS BOARDS ID 28 29 C-15 CASE FANS 1 20 1 0.42 1 20 19 SPARE i-. 30 31 C-16 FANS & A/S HTRS (6) #6 20 1 1.27 20 SPA E SPACE 32 33 C-17 CASE FANS 20 1 0.41 1 0.55 1 1 SPACE 34 35 SPARE 1 20 1 20 1 SPACE 36 37 C-11 CASE RECEPTACLES (4) 20 1 0.54 ARE NOT ADJACENT TO WALLS TO BE ROUTED TOTAL 4.69 ISPACE 38 39 C-16 CASE RECEPTACLE 20 1 L 0.18 PER NEC ARTICLE 220 L SPACE 40 41 C-16 CASE RECEPTACLE AMPS 20 11 0.18 4 � - SPACE 42 TOTAL 7.97 8.97 6.75 KVA PER NEC ARTICLE 220 66 75 56 AMPS TOTAL LOAD 23.69 66 AMPS KVA FEEDER LOADI 23.69 KVA 66 AMPS STOCKROOM gI EjC6F � J N J D 11I I TYP C 04 04 ou A-6 f 1 N N A-7 U (A-6) (A-7) Q3 CH1F-9j11* 33 D-12 +CHIP 31,33 16.710 REF 1-RE1 c=> A-11 TYP 16.711 d co (A-9) -35,37 C: I ZIGERATED CASE ELECTRICAL CONNECTION POINT, TYP A-8 A-9 CH2F-39,411 t 1F-13,15 GROCERY SALES REAR REFRIGERATION ELECTRICAL PLAN L----4 -{ DAIRY COOLER I --J CH2ONTROLLED mr-rRiGE A ICU WA3L DOMPREMOR _ {-- -- -.. _ _ _O NNECTION FORSEPARA Y RIVE TEL DE D N0. �wa�a0 Z awa�eoow CONDUIT HOUSE #2 SYSTEM IN COMPRESSOR HOUSE. ROUTE °z EQ. GROUND PANEL VIA 10OA-3P FACTORY PROVIDED CONTACTOR' o C-15 !� CONDUCTORS i D8�ROST TERMINATION TRANSFORMER TO EFFECTIVELYR G OUNDED 208/12OV, 3 PH, 4W SERVES: REFRIGERATED CASE LIGHTS STRUCTURAL STEEL IN MAIN BUILDING. r I (2) #12 , I { I -i I 16.708 DUPLEX RECEPTACLE FURNISHED WITH (1) #12 225A, M. L. 0. LOCATION: COMPRESSOR HOUSE #2 REFRIGERATED CASE. FINAL ELECTRICAL awaw i Ii 16.702 (2) #10 I 1 i CO!PUNE'C'nON BY CONTRACTOR TYPBCAL. 10,000 AIC PANEL PROVIDED WITH COMPRESSOR HOUSE STOCKROOM I MS63 Y k, i WIRE) FOR LOW VOLTAGE CABLES. ROUTE IN � I ! GROUND BUS {I 480/ MAIN PANEL WALL (WHERE APPLICABLE) FROM BAR JOIST _KIRd Nd I j I CH2F-27 CH2L-21 �' 1/2" AND STUB OUT 3" ABOVE FINISHED FLOOR. I SURFACE MOUNT °-' DESCRIPTION WIRE BRKR L KVA (1) #12 PL RK WIRE DESCRIPTION (3) #10 I © WIRE) UNDER FLOOR SLAB FOR LOW 3/4„ (3) #8 (1) #10 A 3/4„ (3) #8 (1) #8 PIT SIDEWALL TO ALLOW FOR CONDUIT ® 3/4„ 1 C-1 CASE LIGHTS ❑9 20 1 1.27 0.94 1 (1) #8 1 20 #10 D-1 CASE LIGHTS (6) 2 3 C-2 CASE LIGHTS 16.711 POINT OF TRANSITION FROM EMT TO FLEX. ELECTRIC DEFROST 20 1 1 0.92 0.94 PROVIDE CONDUIT AND BRANCH CIRCUITS 1 20 #10 D-2 CASE LIGHTS (6) 4 5 C-3 CASE LIGHTS ANTI -SWEAT HEATERS, AND ELECTRICAL 20 1 1 0.92 0,69 1 20 11 D-5 CASE LIGHTS 6 7 C-4 CASE LIGHTS ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR HOUSE. 12 ❑ 20 1 0.59 1 0.55 1 (1) 1 20 D-6 CASE LIGHTS 8 9 C-8 CASE LIGHTS (6) { #8 20 1 1 0.77 0.55 (1) 1 20 14 D-10 CASE LIGHTS 10 11,C-9 CASE LIGHTS 6) #10 20 1 0.65 0.48 1 20 D-11 CASE LIGHTS 12 13 15 C-10 CASE LIGHTS C-11 CASE LIGHTS. (6) #10 20 20 1 1 0.240.28 1 0.76 1.52 1 1 20 20 #8 D-12 CASE LIGHTS DAIRY COOLER DOOR LTS (6) 14 16 17 SPARE 20 1 ANTI -SWEAT HEATERS TO WIREWAY ON 0.84 1 20 D-4 CASE LIGHTS 18 19 C-13 CASE LIGHTS UNLESS OTHERWISE NOTED. WIRE SIZE AS 20 1 0.83 INDICATED IN SCHEDULE. FINAL TERMINATIONS AT 1 20 SPA E CASE AND IN COMPRESSOR HOUSE BY R.C. REF 0 21 C-14 CASE LIGHTS DETAIL 3-RE1. 20 1 1 0.55 1 20 SPARE 22 23 C-15 CASE LIGHTS 20 1 0.48 1 1 20 SPARE 24 ARE NOT ADJACENT TO WALLS TO BE ROUTED TOTAL 4.69 6-01 4.06 KVA 4. UNDERSLAB CONDUITS SHALL BE 3/4" MIN. PER NEC ARTICLE 220 39 50 34 AMPS 4 � - TOTAL LOAD 14.77 41 AMPS KVA FEEDER LOAD 18.46 KVA 51 AMPS \ {.._ __� .�CF J f vl L__--} L__1' L- . CH2F-10,12,14 CH2F-24 CH2L-16 .t N i KEYNOTES 16.701 ROUTE CONDUITS FOR COMPRESSOR HOUSE "CH" PANEL BRANCH CIRCUITS TO THIS LOCATION AND THROUGH WALL OPENING TO "CH" PANEL WIREWAY PROVIDED INSIDE COMPRESSOR HOUSE. REFER TO ARCHITECTURAL ELEVATIONS AND REFRIGERATION DRAWINGS FOR LOCATIONS OF OPENINGS. 16.702 ROUTE CONDUITS FOR ELECTRIC DEFROST BRANCH CIRCUITS TO THIS LOCATION AND THROUGH WALL OPENING TO DEFROST TERMINATION WIREWAY PROVIDED INSIDE COMPRESSOR HOUSE. REFER TO o ARCHITECTURAL ELEVATIONS AND REFRIGERATION DRAWINGS FOR LOCATIONS OF OPENINGS. 16.706 PROVIDE GROUNDING ELECTRODE ' CO A-13 ICE CREAM FREEZER 13 La U TGROCERY EEZER -13 ,H2F-8 CH2L-8 E STOCKROOM 16.709 1-0 x CH2F-6 L CH2L-6 25 PANEL `{ REF 3-REM1- jj J`' MEAT AND 200V DIST. PANEL DELI COOLER I \�- ANEL "CH2L" D-3 CF J 16.702 U � PANEL "CH2F" ED IY CH PANEL WIREWAY 1 < DEFROST TERMINATION �MIREWAY RACK C 11 ( _ REF 1 -REI mr-rRiGE A ICU WA3L DOMPREMOR _ {-- -- -.. _ _ _O NNECTION FORSEPARA Y RIVE TEL DE D N0. �wa�a0 Z awa�eoow CONDUIT HOUSE #2 SYSTEM IN COMPRESSOR HOUSE. ROUTE °z EQ. GROUND O I GROUNDING ELECTRODE CONDUCTOR FROM o C-15 !� CONDUCTORS i D8�ROST TERMINATION TRANSFORMER TO EFFECTIVELYR G OUNDED WIRE H1F-39 J as WIREWAY RACK D STRUCTURAL STEEL IN MAIN BUILDING. r I (2) #12 , I { I -i I 16.708 DUPLEX RECEPTACLE FURNISHED WITH (1) #12 I N CH2L-23 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN COMPRESSOR HOUSE. REFRIGERATED CASE. FINAL ELECTRICAL awaw i Ii 16.702 (2) #10 I 1 i CO!PUNE'C'nON BY CONTRACTOR TYPBCAL. j f o , I I 16.709 PROVIDE 1-1/2" PVC CONDUIT (WITH PULL STOCKROOM I MS63 Y k, i WIRE) FOR LOW VOLTAGE CABLES. ROUTE IN � I ! L O {I 480/ MAIN PANEL WALL (WHERE APPLICABLE) FROM BAR JOIST _KIRd Nd I j I CH2F-27 CH2L-21 �' 1/2" AND STUB OUT 3" ABOVE FINISHED FLOOR. I I °-' PROVIDE BUSHING WHERE CONDUIT { �f 112.5 kVA XFMR 1/2" TERMINATES AT JOIST. (1) #12 i ❑ 16.710 PROVIDE 1-1/2" PVC CONDUIT (WITH PULL (3) #10 I © WIRE) UNDER FLOOR SLAB FOR LOW 3/4„ (3) #8 (1) #10 VOLTAGE CABLES. STUB CONDUIT THROUGH 3/4„ (3) #8 (1) #8 PIT SIDEWALL TO ALLOW FOR CONDUIT ® 3/4„ (3) #6 COUPLING INSTALLATION. AT WALL, STUB ❑9 3/4" CONDUIT UP TO BAR JOIST AND TERMINATE (1) #8 WALK-IN UNIT COOLER FEEDER SCHEDULE WITH BUSHING. (! COIL FANS 16.711 POINT OF TRANSITION FROM EMT TO FLEX. ELECTRIC DEFROST EQ. GROUND NOTES PROVIDE CONDUIT AND BRANCH CIRCUITS SIZE (CF) FOR REFRIGERATED CASE FANS, LIGHTS, (ED) WIRE ANTI -SWEAT HEATERS, AND ELECTRICAL 3f4" j (2) #12 (1) DEFROST (IF REQUIRED). TERMINATION TO E.C. SHALL PROVIDE CONDUIT AND WIRE FOR EVAP. COIL FAN (CF) AND 11 3/4" (2) #12 REFRIGERATED CASE ELECTRICAL CONNECTION (1) #8 ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR HOUSE. 12 ❑ POINT BY R.C. REFER TO CASE CONNECTION (2) #12 (2) #6 (1) WIRING DETAIL. 16.714 DAIRY COOLER DOORS: JUNCTION BOX #10 { 13 1 3/4„ FURNISHED WITH DOORS. FINAL CONNECTION (3) #10 (1) #10 14 16.716 SLAVE WIRING BETWEEN REFRIGERATED 1 (2) #12 (3) #8 (1) #10 CASES IN WIREWAY PROVIDED BY (2) #10 (3) #8 (1) #8 REFRIGERATION CONTRACTOR. REFRIGERATED CASE WIRING NOTES 1. E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE FANS, LIGHTS AND { ANTI -SWEAT HEATERS TO WIREWAY ON { { COMPRESSOR HOUSE WALL BELOW "CH" PANELS, I i I UNLESS OTHERWISE NOTED. WIRE SIZE AS INDICATED IN SCHEDULE. FINAL TERMINATIONS AT CASE AND IN COMPRESSOR HOUSE BY R.C. REF { DETAIL 3-RE1. 2. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED ON DRAWING BY RECTANGULAR i' I � � BOX. 3. CIRCUITS FOR CASES ON SALES FLOOR THAT ARE NOT ADJACENT TO WALLS TO BE ROUTED C i " UNDER SLAB. REFER TO DETAIL 3-RE1. 4. UNDERSLAB CONDUITS SHALL BE 3/4" MIN. 4 � - PANELBOARD NOTES (1) TERMINATE GROUND ON ISOLATED GROUND BUS_ \ (2) INSTALL LOCKING DEVICE FURNISHED WITH PANELBOARD (LOCK -OFF FOR MAINTENANCE). - (3) INSTALL LOCKING DEVICE FURNISHED WITH 1 PANELBOARD (LOCK -ON FOR CRITICAL LOAD). 25 PANEL `{ REF 3-REM1- jj J`' MEAT AND 200V DIST. PANEL DELI COOLER I \�- ANEL "CH2L" D-3 CF J 16.702 U � PANEL "CH2F" ED IY CH PANEL WIREWAY 1 < DEFROST TERMINATION �MIREWAY RACK C 11 ( _ REF 1 -REI mr-rRiGE A ICU WA3L DOMPREMOR _ {-- -- -.. _ _ _O (4) GFI BREAKER. N0. �wa�a0 Z awa�eoow CONDUIT HOUSE #2 05/04/05 °z EQ. GROUND O I (5) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. o C-15 !� CONDUCTORS i D8�ROST TERMINATION (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR WIRE H1F-39 J as WIREWAY RACK D VOLTAGE DROP. SIZE EQUIPMENT GROUNDING r CH2F-29 i (2) #12 , I { I -i I CONDUCTOR PROPORTIONALLY PER NEC. (1) #12 I N CH2L-23 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN COMPRESSOR HOUSE. (7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE awaw i Ii 16.702 (2) #10 I 1 i FAULT CURRENT FOR INTERRUPTING RATINGS. 1 o , I I (8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. STOCKROOM I MS63 Y k, i (9) FACTORY WIRED TO LOAD. � J1 L O {I 480/ MAIN PANEL (10) BREAKER SHALL BE HIGH MAGNETIC TYPE. _KIRd Nd I j I CH2F-27 CH2L-21 �' 1/2" (11) THRU CONTACTOR. I °-' (X) DESIGNATES "SMART" BREAKER. { �f 112.5 kVA XFMR 1/2" (3) #12 (1) #12 ❑ 25 PANEL `{ REF 3-REM1- jj J`' MEAT AND 200V DIST. PANEL DELI COOLER I \�- ANEL "CH2L" D-3 CF J 16.702 U � PANEL "CH2F" ED IY CH PANEL WIREWAY 1 < DEFROST TERMINATION �MIREWAY RACK C 11 ( _ REF 1 -REI W y p Q p p Y J LL !r O W a O Z O w o W� N Q Z O � aaggLL�oazj�'�'� � WR���y�`^QJyt"ioom Ow aysz ac 8w¢J�'NLLa Z o 3t2z o oc�i'`��o #w�w�n�az o� z z a Q N z K PEoopW W yW _ s F� z H- Lwmr �Xcol-rcoJP to �D2 �aa52iwi 0wwz <2 mr-rRiGE A ICU WA3L LLLU IMIU ULFmUS I 1'ttUtlN Jla'1tUULt N0. �wa�a0 Z awa�eoow CONDUIT NUMBER AND SIZE OF 05/04/05 °z EQ. GROUND O NOTES wZzH LL o SIZE CONDUCTORS w WIRE as J awaW [ r 1/2" (2) #12 w 0 (1) #12 E- . E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN COMPRESSOR HOUSE. �2 awaw 1/2" (2) #10 (1) #10 Y w 02Z U w W Z W U300m w FINAL TERMINATIONS AT CASE AND IN COMPRESSOR HOUSE BY R.C. Ta m�SV) z � Ir I- 0 L O =wDmra-E a _KIRd Nd Q3 1/2" (2) #8 (1) #8 REF DETAILS 3-RE1 AND 4 -REI. ® 1/2" (3) #12 (1) #12 ❑ 1/2" (3) #10 (1) #10 © 3/4„ (3) #8 (1) #10 7 3/4„ (3) #8 (1) #8 ® 3/4„ (3) #6 (1) #10 ❑9 3/4" (3) #6 (1) #8 WALK-IN UNIT COOLER FEEDER SCHEDULE N0. CONDUIT COIL FANS ELECTRIC DEFROST EQ. GROUND NOTES SIZE (CF) (ED) WIRE 10 3f4" (2) #12 (2) #12 (1) #12 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR EVAP. COIL FAN (CF) AND 11 3/4" (2) #12 (2) #8 (1) #8 ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR HOUSE. 12 ❑ 3/4" (2) #12 (2) #6 (1) FINAL TERMINATIONS AT COIL AND IN COMPRESSOR HOUSE BY R.C. #10 REF DETAIL 2-RE1. 13 1 3/4„ (2) #12 (3) #10 (1) #10 14 3/4" 1 (2) #12 (3) #8 (1) #10 15 1" (2) #10 (3) #8 (1) #8 W y p Q p p Y J LL !r O W a O Z O w o W� N Q Z O � aaggLL�oazj�'�'� � WR���y�`^QJyt"ioom Ow aysz ac 8w¢J�'NLLa Z o 3t2z o oc�i'`��o #w�w�n�az o� z z a Q N z K PEoopW W yW _ s F� z H- Lwmr �Xcol-rcoJP to �D2 �aa52iwi 0wwz <2 ti z0 9 oa.� OF 11/17/04 01/24/05 6 �Fi ON �wa�a0 Z awa�eoow C.C.D. #13 E,3wzoAAK 05/04/05 °z w�Zm a 0.U¢ O a it wZzH LL o xw--0 m U w ti ISSUE BLOCK f_1�, 11/17/04 01/24/05 C.C.D. #2 C.C.D. #8 ON 02/28/05 C.C.D. #13 Q 05/04/05 C.C.D. #17 w�Zm a 0.U¢ O a it O N �ao� a0- as J awaW W r N�0 t'1 w 0 o E- . - W J awaw �a�o Y w 02Z U w W Z W U300m w W 1 Ta m�SV) z � Ir I- 0 L O ISSUE BLOCK f_1�, 11/17/04 01/24/05 C.C.D. #2 C.C.D. #8 tA\ i3 & 02/28/05 C.C.D. #13 Q 05/04/05 C.C.D. #17 w�Zm a 0.U¢ a it to Z :}w J a0- as J awaW In N�0 w �> aj 5 m U CHECKED BY: DRAWN BY: FILE NAME: RE1.1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 o� U Z W w Oo U r N 0 w�Zm a 0.U¢ a it to Z :}w J a0- as J awaW In N�0 w �> aj 5 m U - W J awaw �a�o Y w 02Z U FaQ_jz W a W Z W U300m w W 1 Ta m�SV) z � Ir I- 0 z =wDmra-E a _KIRd Nd m o REFRIG ELECTP!CAL PLAN SHEET: RE1.1 0 0 0 f , i jy TYP P,� y o I f `— h` — I / ICE CREAM u STOCKROOM 32 ABJ ABJ A J ABJ, ✓xlf16.715 °- �.\a`' y ay \a .aa DAIRY COOLER -/ y H1 P1 ; sLl ✓ f .- df 1111 1 .715 � �� i R A e� � � y � y g l y' 6 {_ _f J a 18 1 'f TYP y� GROCERY` j FREEZER P --- 71-- 4 H TYP 19 ABJ `® e STOCKROOM y ABJ SUSPEND_SlWY4ROOM OTYP j LiOHTUI'IXTURES HERE I REO ED TO AVOID CONFLICTS WITH REFRIGERATION RJPING. MOUNT AS HIGH AS A/� POSSIBLE m 0 0 Y U 0 cn ABJ MEAT t i s I I t � i q € f # 1 y f 7f fI E d LIGHT FIXTURE TYPE 1 AB VE COOLERI1SHALL I B, MOUNTED TO THE EtO�TOM OF BAR JOIST I Ll �i f y i !b Sff i -- f P F °°dif C i f y < s1 f fit, _ L t` IEP F00D FREEZER �O J 'f fl 3 I D 16. 15 U ILITY I f PROVIDE LITHONIA. LP6—SDT-6E1 LP 75W PAR30 RECESSED MOUNTED FIXTURE i f a ( f f lN', H C p if f i w � oa ooY (n �' p wF2 WO 4ZQ w p �p\KOKW�ZNZ 3�F-p � �Q�$04 pRW V�KVV yc'cpiajwooFawt�t��ws pyoWW VVpp p 3:asppp?Oaj ZOO ydy,,,,QO04 y W-Z:P.iW0..0. pco J q`C aizv S CL ooF � � srg>n0 41 y12 €ppw`KOKV6 U) Fypx]*i<<PLL<w%wK ISSUE BLOCK Z(n p 10/22/04 O- "wOW FILE NAME: � M<- C. C. D. #2 062504 01/24/05 E-3:2 wzoa z NeJLL n:3 K aZa�Xx © CV E U) wzv�zl_ w zlw 0 xw�m V J ISSUE BLOCK 10/22/04 C.C.D. #1 FILE NAME: GE1 C. C. D. #2 062504 01/24/05 C.C.D. #8 z NeJLL n:3 �= © CV E w< W w V)�mmIn R. — ~ W J O Lu azo W w W r ^�1 E 0 o W a te. w 0 D w0 ata. ISSUE BLOCK 10/22/04 C.C.D. #1 FILE NAME: GE1 C. C. D. #2 062504 01/24/05 C.C.D. #8 CHECKED BY: DRAWN BY: FILE NAME: GE1 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/041 xr O O ;2E w _omw70 W N Sl1 O J z NeJLL n:3 �= a w< W w V)�mmIn w — ~ W J uj wawa Df Zo Lu azo W w �Z Ua 0 Zlil V3 Nin -5v> u,iZ �\ W a te. w 0 D w0 ata. SHEET: GE1 o I o S 3 zz riyl I LLJ % <✓/ji4 i GFI +48- L_ REF 1-E2.4 ( x •--s .,.�,� ... �.._...._..... f...._.w,^a 1 9 1 A WP E I PROVIDE TIE WIRES FOR I ( mM RACKT.Q 0� { , s - j �__ [.. I _ I I FLEXIBLE METAL CONDUIT PART 2/2) LID 166fl5 "'""-" 1 + I BOX HANGER - THIS IS - L 1 ;� NOT PART OF THE CEILING 1I _ I ADJUSTABLE T -BAR SUSPENSION TYP i �t 4- I 1 BOX HANGER TO SPAN -. ^ _._ ., _. _ ._- ..._..M_ .._ ,_,.^ :J _ .�_..1 1_1 La<�. 1 24" LENGTH OF SUPPORT CLIP TO TIE CEILING TILE. (BOX DAIRY (9 tl- I -i WIRE AT MAXIMUM 4'-6" G J i- S ; i ! COOLER SUPPORT PER NEC SPACING. ROUTE CONDUIT TO JUNCTION JUNCTION BOX_ BOX AT BAR JOIST FLUSH MOUNTED ; j -I.._._.. __m._ IN LAY -IN CEILING _ ate-- wi. _ } _ 1 1 Ak i% r # n 1= ma 0 a f ICE CREAM FREEZER i� 4 16.715 # '. I�I 1 L4D2 meal �e;5STEEL COVERPLATE , 1w GROCERY I' FREEZER I 3 , STRAIN RELIEF 4 ton If € I § a 1 : IL "'�_--'...:,r:e s`�'a-,s- ....,r.::�-�`' '�•�'ac,.,:.:r*€ .�.. -ra...xa:.r--„,'=.;har ::s_, .,.^•�v'-*�- kaF '._..,,._. ._.,. _ 1 DROP CORD TO BE TYPE SO,3 } 1 TERMINATE WITH DEVICE AS NOTED ON - EQUIPMENT SCHEDULE. MOUNTING HEIGHT TO BOTTOM AS INDICATED ON EQUIPMENT SCHEDULE. PROVIDE STRAIN; ❑ RELIEF IF JUNCTION BOX IS USED F 1 30A, +60 FINPL SUSPENDED DROP CORD CONNECTION j s' � 'COMPACTOR BY OTHERS NTS 05.25.01 EC04 COMPACTOR DEODORIZER WP, GFI, +48"a I [g L4D2 \ / 16.715__ STOCKROOM ' a iL �� i `'.Wp.r"Y.«,M"_"'•f.."erv�.td ��d'+qr+"<e*rv4^"J'.. xr.,.y.,..y ,.... .y.. } 1 v '1 i3p 2 30A +60' FIN,' =' 16.650 H1B CONNECTION TO 4 ss 1� 5 COMPACTOR BY OTHERS # i 1 Tlp J: 71, .....ASTE--01L -TAN4; y {? 16.4 1 a :,x L4D2 +48' j, 4 i TYP r._ 1 16.422 b,+66" : 1 INSECT CONTROL, 11 2 13i� ' '4 u- L4D2 li GROCERY EQUIPMENT SCHEDULE MOUNT TO BASE s OF CASE ROUTE CONDUIT FROM I EQUIPMENT CONNECTION D04A POINT ALONG BASE OF. BAKERY EQUIPMENT SCHEDULE CASE TO JUNCTION (PART./3) BOX. ATTACH CONDUIT L4D3 TO BASE OF CASE FOR 3 SUPPORT. CONCEAL zow NJ FROM VIEW AS MUCH NO. DESCRIPTION MANUFACTURER MODEL NO. VOLT PH AMPS HP VA TERMINATION MTG. HT. NOTES B04 SCALE/LABELER HOBART QUANTUM 120/1 1.50 t WP GFI DUPLEX, NEMA: 5-20R — — BD5 PAN WASHER LVO FL14 48OZ3 37,10 Q JUNCTION BOX WP t +12” — B07 BREAD SLICER BERKEL GMB 120/1 DELI FREEZER 1/2 NEMA: L5 -20R, CONNECTOR +78" 2,3 B17 PASTRY CASES AIR SYSTEMS — 120/1 7.50 16.712 DUPLEX FURNISHED W/CASE — — 818,,., NOT USED BAKERY z i B26 ICING TABLE BELSHAW H & 1 2 208/1 1 900 WP RECEPTACLE, NEMA: L6 -15R +42" 2 B35L RACK OVEN (ELEC) A: CONTROLS HOBART H021OE2 480/3 120/1 64.70 16,00 JUNCTION BOX JUNCTION BOX +96" +96" 3 3 636 PROOF BOX HOBART HP2-5 208/1 1 36.00 JUNCTION BOX +96" 3,5 649 THERMOGLAZE / THERMOLIZER A: THERMOLIZER BELSHAW TG -50 / TZ -6 TZ -17 208/1 208/1 40.30 20.00 RECEPTACLE, PIN RECEPTACLE, PIN & SLEEVE #330R6W & SLEEVE #330R6W — — — — MEAT PREP EQUIPMENT SCHEDULE GE2 N0. DESCRIPTION IMANUFACTURIER IMODEL N0. I VOLT H AMPS I HP I VA ITERMINATION MTG. HT. I NOTES MD4 SCALE LABELER HOBART QUANTUM 1 120/1 1.50 1 1 INEMA: L5 -20R, CONNECTOR +48" 1 2,3 Mit 1WRAPPER WIN -HOLT WHSS-1 1 120/1 1 &00 1 1 INEMA: L5 -20R, CONNECTOR +48" 1 2,3 DELI EQUIPMENT SCHEDULE NO. DESCRIPTION MANUFACTURER MODEL NO. VOLT PH AMPS HP VA TERMINATION MTG. HT. NOTES D04 SCALE/LABELER HOBART QUANTUM 120/1 1.50 DUPLEX FURNISHED W/ CASE — — D04A SCALE/LABELER HOBART QUANTUM 120/1 1.50 WP GFI DUPLEX, NEMA: 5-20R +42", U.N.O. — D05 WRAPPER WIN—HOLT WHSS-1 120/1 8.00 WP GFI DUPLEX, NEMA: 5-20R +42", U.N.O. — D07 _ SLICER HOBART 2812 120/1 1/2 WP GFI DUPLEX, NEMA: 5-20R +42", U.N.O. — D13WORKTOP REFRIGERATOR TRUE TWT -72 120/1 10.50 WP GFI DUPLEX, NEMA: 5-20R +42", U.N.O. — D56 FRYER W/ BASKET LIFT A: FRYER FILTER PUMP FRYMASTER 1 FPC128BLC 480/3 1 120/1 1 35.00 10.00 1 1 JUNCTION BOX IJUNCTION BOX +20" +20" 4 4 D58 DELI FRYER FRYMASTER 1136C 480/3 1 44.00 I JUNCTION BOX +20" 4 D59,. _ DOUBLE ROTISSERIE HOBART JHR7 208/3 1 24.70 1 4 D65 HOT FOOD SERV CASE CUSTOM DELI'S IDILW 1120/208/31 1 1 7950 IJUNCTION BOX +12" 1 — PRODUCE EQUIPMENT SCHEDULE N0. IDESCRIPTION IMANUFACTURIER IMODEL NO. I VOLT PH I AMPS I HP I VA ITERMINATION MTG. HT. I NOTES PO4 SCALE/LABELER HOil 1 120/1 1 1.50 1 1 jWP GFI DUPLEX NEMA: 5-20R +48" P05 1WRAPPER WIN—HOLT WHSS-1 1 120/1 1 8.00 1 1 IWP G { 4 6 MOUNT TO BASE OF CASE TYP OF 4--\ SERVICE �46 1 DELI. +48" f I I ipY � i M1 '0 ROTISSERIE HOOD. LIGHTS 1 y55 / L GFI, 11 +48" J 59 16.715 DELI! UTILITY 16.712 INSECT CONTROL, POULTRY COOLER i MOUNT TO BASE s OF CASE ROUTE CONDUIT FROM I EQUIPMENT CONNECTION D04A POINT ALONG BASE OF. 17 CASE TO JUNCTION (PART./3) BOX. ATTACH CONDUIT L4D3 TO BASE OF CASE FOR 3 SUPPORT. CONCEAL zow NJ FROM VIEW AS MUCH J AS PRACTICAL w U _ a J +12" v .. { 4 6 MOUNT TO BASE OF CASE TYP OF 4--\ SERVICE �46 1 DELI. +48" f I I ipY � i M1 '0 ROTISSERIE HOOD. LIGHTS 1 y55 / L GFI, 11 +48" J 59 16.715 DELI! UTILITY 16.712 INSECT CONTROL, POULTRY COOLER i zcnO s L4US 16 I g W W��NOOZ W,QhI�W „I 17 to H Z ^z00 'MM¢ C, § Z�O WKWQ Ill ; 9 16.715 zow NJ O J i F ,F CUSTOMER SERVICE PUSHBUTTON +54". ROUTE CONDUIT FROM PUSHBUTTON TO BUZZER ON. WALL INSIDE COOLER BOX. SEAL PENIE.TRATION INTO COOLER BOX WITH SILICONE SEALANT, REF 2—GE2 LFS BRKR/ TFS STACKED 9 °, H4B - L4D3/L4D4/H4C' STACKED L4D1/L4D2/ T4D STACKED.=� FI DUPLEX, NEMA: 5-20R +48" - WP, GFI, +48" a,+48„ PO4 t i PROVIDE INTERLOCK !,WIRING BETWEEN OVEN ANDp 4D L3 BAKERY OVEN FAN. REFER TO EQUIPMENT SUPPLIER'S I' 479 WIRING DIAGRAM FOR ,TERMINATION POINT AT OVEN A, 51 "ROUTE FLEX CONDUIT FROM WIRING DEVICE ALONG BAS ^ E OF CASE OVER TO J.B. ATTACH CONDUIT TYP OF 3 TO BASE OF CASE FOR SUPPORT TYP / " �„a ' (PART. 1 D04 ,a� e fihOUNT,:7(i. A-"-L4Di f'— ROUTE CONDUIT a OF CASE 3 .UNDERGROUND (TYP. B04 r 49 51 51 __ J 1� +12 a _ (PART. 2/3) D07 L, L4D3 D05 MOUNT TO BASE +42"� OF CASE TYP OF 3( /39 (a' 013 i BAKERY 1 1 a,+b4 L , GFI, + 16.220 EDC4/POWER' WALL DRY PRODUCE PREP PRODUCE COOLER 3:) +78" GE2 GFI, +48" INSECT CONTROL, GFI, +96" � C +60", R/0 ^ WATER FILTRATION i-' s 1 p r iF 1 E� I INSECT CONTROL o' cl GFI, +96 1 ' a,+54' - t WP, GFI { +48"� a y fi zcnO s L4US 16 I g W W��NOOZ W,QhI�W , 17 to H Z ^z00 'MM¢ C, 45 43 Z�O WKWQ Q 0~ _ 0 9 16.715 zow NJ J 41L41D3 J J w U _ a :J FOFw o aw¢1,.i .. _ < = Z Q ~a z_ ft JZ d 0 i L4D3 t d I ¢ w =wZ)w<w _wV)d Inm fn 0 INSECT CONTROL 16.715 Q GFI +96" WP t 2f .f BAKERY AND w DELI FREEZER 3 16.662 Ik } 16.712 TYP GE2 16.712 BAKERY z i 9 4 COOLER 1 +{ m 3 GE2 p I� _< O 1 1 a,+b4 L , GFI, + 16.220 EDC4/POWER' WALL DRY PRODUCE PREP PRODUCE COOLER 3:) +78" GE2 GFI, +48" INSECT CONTROL, GFI, +96" � C +60", R/0 ^ WATER FILTRATION i-' s 1 p r iF 1 E� I INSECT CONTROL o' cl GFI, +96 1 ' a,+54' - t WP, GFI { +48"� a y fi zcnO s inom � ��//��,•,F'W--'^ooz g W W��NOOZ W,QhI�W , ➢(0002pNNppp ` to H Z ^z00 'MM¢ C, f Z�O WKWQ Q 0~ _ 0 9 J aw¢W o zow NJ Z U w U _ a :J FOFw o aw¢1,.i .. _ < = Z Q ~a z ft JZ d 0 i w t d I ¢ w =wZ)w<w _wV)d Inm fn 0 INSECT CONTROL GFI +96" 16.662 1 ! z i d 1 0 +24" f� h 8 _ ! E3 G Lo 1 � 1. 8 1 , STOCKROOM (( wµ{ ;H j r._ 1 16.712 I 16.715 7j I 1 r1 J J ::_: OWP' _ �•u: I 4 i � I VP , 10 iii i l L4D2 I ! I § a I MEAT COOLER€� li LT F > 7 112 D2 UTILITY �i Ii <GE2 48 E j --TO CUSTOMER SERVICE PUSHBUTTON, REF 1—GE2 T6.712 ij —SEAFOOD — FREEZER r 16;715 F t l I 2 s S INSECT CONTROL I II GFIj +24" I w N o4 0-0 OiAQ Z2W0 WZ¢ L=) zr��Qo�oi `; rnz \�o¢w � WI"�O�N �X O�ZfnK tlx � rn=rjam'�'o�f-aW€w� pyo 000000 3wzwt-n�gwa ZQZoa Q z0mo3 z 1�a'�aotn�Qa3 J QQ� ��FIiCfAVV�NJ a OZO��f-IWiK�W UrOWOw U7 r-1 zcnO N r� O LLJ inom FILE NAME: ��//��,•,F'W--'^ooz C. C. D. #2 W W��NOOZ W,QhI�W 01/24/05 ➢(0002pNNppp ` to H Z ^z00 'MM¢ C, � Z�O WKWQ Q 0~ _ 0 C.C.D. #16 J aw¢W o zow NJ Z U w U r-1 ISSUE BLOCK O N r� O LLJ F a FILE NAME: 11 /17/04 C. C. D. #2 O 01/24/05 C.C.D. #8 ao�a w J N 04/14/05 ccW O04/20/05 Q 0~ _ 0 C.C.D. #16 J aw¢W o m 0:2 m 0 _ = ma = w U _ a :J FOFw o aw¢1,.i .. _ < = Z Q ~a z ft JZ d 0 ISSUE BLOCK 10/22/04 C.C.D. #1 FILE NAME: 11 /17/04 C. C. D. #2 062504 01/24/05 C.C.D. #8 ao�a w J N 04/14/05 F. P. P. O04/20/05 Q 0~ _ 0 C.C.D. #16 J aw¢W o m 0:2 m 0 _ = ma = w U _ a :J FOFw o aw¢1,.i .. _ < = Z Q ~a -~coo 1woww ft JZ d of U Q Z:2 W w3oow� CHECKED BY: DRAWN BY: FILE NAME: GE2 PROTO CYCLE: 062504 DOCUMENT DATE: 08/11/04 w� OU 2F w Oo } _U N O w�U � o ao�a w J N J w Q �Az Q 0~ _ 0 J aw¢W o m 0:2 m 0 _ = ma = w U _ a :J FOFw o aw¢1,.i .. _ < = Z Q ~a -~coo 1woww ft JZ d of U Q Z:2 W w3oow� w In 0oz Boit ¢ w =wZ)w<w _wV)d Inm fn 0 ENLARGED GROCERY POWER PLANS AND SCHEDULES SHEET: GE2 i FIRE ALARM SYMBOLS LEGEND Al / COMPLIANCE NOTES 5. Remote Annunciator(s) will feature Point I.D. of 9. Cooking hood suppression systems (if any) 14. Wiring will be installed per (The NEC) NFPA all devices/zones in plain English display, and at shall be connected to the system to cause on 70, Part 760 and all other applicable sections IBC - IFC- "Proprietary System" , FIRE ALARM CONTROL PANEL 1. This system design is based upon compliance least one will be located at a normally attended "alarm signal upon agent discharge, per NFPA 17, {02 ). All equipment shall be properly listed per CPU FIRERADALARM 9CO Fe -] MANUAL PULL STATION - POPIT MODULE location On Site. The CPU cabinet has no 7-6 and 7- 7 ('98) and NFPA 72, 3-8.4.3 ('99). NFPA 72 ('99), 1-4. ® RADIONICS D461 SYSTEM SENSOR WALL MOUNT WF WATERFLOW ALARM PRESSURE FPTI RADIONICS D9127U with the IBC & IFC codes. The Occupancy Class is annunciator or user interface Controls, and is o CONTROL ANNUNCIATOR HV HORN/STROBE LIGHT P1224MCw. MERCANTILE per 309.1 The facility Will be See suppression contractors shop drawings far CP -SA SWITCH (PROVIDED BY OTHERS) P y cabinet housing non- analog addressable details. 15. This system is designated as a "Proprietary RADIONICS D1256 75 cd UNLESS OTHERWISE NOTED. 9 ( g ) y g p y COOKING HOOD SUPPRESSION protected throughout by a fully supervised fire circuity only. " SYSTEM (POINT OF CONNECTION H HIGH/LOW AIR SUPERVISORY SWITCH DRY NORMALLY OPEN Y Y Supervising Station System in accordance with ANNUNCIATOR CONTACTS sprinkler system per 903.2.6, NFPA 13 and NFPA q NFPA 72, 5-3 0 10. All NON -required devices indicated in the SA ONLY). SYSTEM SENSOR WEATHERPROOF (PROVIDED BY OTHERS) 72 99 NO manual Stations required at each 6. At least one manual station will be installed ('99) with al hours of Stand-by RADIONICS D1257 submittal if an ore voluntarily provided and ore ❑V WALL MOUNT STROBE LIGHT S1224MCK. q ( "supplementary" „ y p power then 5 minutes in "alarm" per NFPA 72, NOTIFICATION POWER SUPPLY wP 75cd UNLESS OTHERWISE NOTED. WATER FLOW INDICATOR SWITCH END OF LINE RESISTOR / exit per 907-2.7 and located Where required by the AHJ, per NEPA designated as su lementar in nature, as NPS #x SYSTEM SENSOR CEILING MOUNT (PROVIDED BY OTHERS) DEVICE 72, 3-8.3,1.2 99 Unless otherwise specified b g PP Y designated dfo Store management personnel are ALTRONIX AL802ULADA ( ) P Y defined in NEPA 72, 1-4 99' V STROBE LIGHT. SC24115W. 115cd ( ) designated far 1 hour runner service. O 2, Electronic sprinkler supervisory service is the AHJ, it will be located at the continuously SMOKE DETECTOR UNLESS OTHERWISE NOTED. SPRINKLER SYSTEM CONTROL VALVE O DETECTION SYSTEMS SYSTEM SENSOR WEATHERPROOF SUPERVISORY TAMPER SWITCH REVISION NO. X provided in accordance with 903.4 and this is a attended location On site, per the drawing. 11. Audible and Visual notification appliances are 16. These notes do NOT supersede requirements DS284 SYSTEM SENSOR CEILING MOUNT WALL MOUNT HORN/STROBE LIGHT (PROVIDED BY OTHERS) N. NORMALLY OPEN PROPRIETARY System under NFPA 72, 5-3 ('99). provided as indicated on the plan. of Other trades, specifically including Mechanical:. HV 7. One smoke detector will be installed above the HV HORN/STROBE LIGHT. PC24115W. WP P1224MCK. 75cd UNLESS OTHERWISE PS -POWER SUPPLY ASSIGNED TO DUCT SMOKE DETECTOR 115cd UNLESS OTHERWISE NOTED. NOTED. ASSOCIATED CIRCUITS. WP WEATHERPROOF 3, Flow Switches will be provided on all sprinkler CPU in accordance with NFPA 72, 1-5,6('99). 12, Wal-Mart Alarm Division will install the fire 17. Applicable State and Local modifications _ (POINT OF CONNECTION LP -LOOP ASSIGNED TO ASSOCIATED r - - - - - - - - - - - risers with alarm zoningto coincide with sprinkler alarm where legally entitled b licensing, -, ONLY AND PROVIDED BY ALL NAC CIRCUITS WILL BE 12 P 9 Y Y 9 adopted through due process of IOW and Which 1O1 SYSTEM SENSOR WALL MOUNT POWER SUPPLY. 8. Air Handling Units in excess Of 2000 Cfm Certification or exemption, Local 1 z I OTHERS. REFER 70 PLANS V STROBE LIGHT S1224MCW. 75 cd (AWG. ALL OTHER FIRE ALARM I Zoning. permitting, P Conflict With these nates Shall supersede and L__J 10" WATERFLOW BELL (PROVIDED D -DEVICE NUMBER ASSIGNED TO which include UL268A duct smoke detectors contractor to be used elsewhere. FOR EXACT QUANTITY OF UNLESS OTHERWISE NOTED. O (WIRE WILL BE 18 AWG I Copies should be Conveyed to the Contact person AND INSTALLED BY OTHERS) ASSOCIATED LOOP. L - which shall shut down their respective fans and indicated below. DUCT SMOKE DETECTORS - - - - - - - - - - 4. Tamper switches will be provided On all valves, ,. PER UNIT.) and where applicable, all other elements essential cause a supervisory' signal on the CPU per NFPA 13. Off Premises, Automatic Emergency Forces 90A, 4-4 ('99). See scope of Mechanical work Notification will be via 2 -line DACT to Wal -Mart's Direct fire olarm related ONLY compliance issues to be proper operation of the sprinkler will also elsewhere. { ) P be supervised. UL Listed (UUFX) center. See UL File #S3152-1 to TVA Fire &Life Safety 23937 Research Dr. O7 for certificate information. Farmington Hills, MI 48335 PHONE: 248-476-0000 FAX: 248-476-1597 a q a 11 10 9 8 - � w; ;'i 6 5 ) O O l Z ) �1 I� J I I 1 I 4 I L_____1 _. t I I I i t : ' ;.- 11, IPS 2 uE "0 "_.� PSI . ° ,: r - € I I K i'1:. ` 2 75cd `, PS 2 5 Ea , Iii Ilili LP 1 V i LP- 1 HV V LP 1 r + _ I II I,u D 3 O75cd = D 4 O � o D 9 , N4 _ y//Y'�)�,�L.�/(Y�/�] y (//�[�')�� y(/`(�)�� y l(/y�)� 4 _` .,,,, _" ° .. gam. � - P,:*„ „ it y.11! V i V V • , V • ` V ` til {Y� __ ,,,, „�m��,_ d.:m.__.._.s .._...3-- F. ---W- .,_,_ _. mm O s s 4 PS 2 -75cd r PS r 75cd PS 2 TO BE PROVIDED AND INSTALLED _ Mill f1 .�D 2 �._._ z 1 RTU38 P RCEIVING LL75cdO LP- h RTU 371 2 1Nz��, V LP i tv 1I`', � �i�Hc �c Do-ld�Hc d�Hc � WIRED &YKELECTRICARACOONTRACTOR. -„„, E � .,.,_.,- _. w .w.. .. ,`._.D _,_ a ___ f e.'1 _... I, ',„I D 8 I 111 BY SPR(iN14 � -ii 0. LUBE AND TIRE 1. ( '_. , I „ _. a - .,. ” MOUNTING AREA NPs #t I I ,"° D ; 075cd - 75cd® D- 75cd0 D 7' r ,, _ 11 NPS #2 it . ,,�>,,,,� ::.,:, I' .. , -,.,,. �' -,__ � ., .`---" --�",�'--`k.`-,- ° S - i V t 4 ''. WP - 'k' , n A r j r Ii, B -.. D- t PS -1 I 111 _ .,. ::., _,... II., 6 • N: i'-�. '^• ” i t III, i LP- 2 1 _ 7 r >I... - - , __ - _ .__ --......_ .. - ---. _. -.. _. _....--......----_._.-__,.,._._.—,... __-_- ---r-'--.. _ ..-_..._. ,..... --�_.._-...... _... __.-__�-... .- _ s ,.._ -.. ... _ _..- r III__ _ ._16 - ".`=---- ! NNwv .,. .�._ �.- y: . _ .-_'-- :, _ - 75cd -;!' >,,,. u"' „,�,., ""`,.w,._,m. m..7'-' J r .. _ _ ,, ,: :: , `_•" : ` V : P - 1 LP 2. , > - 75cd PS- 2 G HV ,. - r - w..,: 'I a:� u„I ,.,y .._,�w,:,. v - -._ l.:lp I:'li', s ': ,. - 6,,,,. ,D . ' --..,,„ ' _ PS- 1 - ,.>PS 2 _...� r,I :I . FD- S ❑ I O LP z ,�. --' " +"ry`r.E CREA��1 NN . �- �'---- -` N SPRINKLER' cPu 2 EDG1 �I - IN VOICING, LP z D LP 2 - F� - 75cd PS- 1 PS- 1 75cd I -- i, ':tJPS UPC c . i HY -*: s ., ..: ,=,.-,,.-�.> i _ PS 2 T KR - ; _ ,, I ,__ _-. ...,. _.r _ ,::r +'G Ie,s _ _ -= :I::: ,1..__, _ n D-. 5 75cd p_i 1 p 1 S OC OOM LP 2 v _ STO KR M -a--„.-„,_._ C 00 ❑ O 2 +i ---:_ LP 2 WP REEZ 11, :1,: HV LP 1 LP 1 V P 1 cd ,s�`- �.,,. _ =-- --. V : RTU 30 1 9 „ _ p .. - - : 75cd .>.. „ _ t _ ,_ .,,,,,, . �.„ .,” - a: _._III c......1 W o iI O _ O HV O - z -- f's', ;i.,,_. D 7 D- 6 LP- 1 ,_:I - ❑ r .."L �'I^_ =.m , ". I. - , I '` .. __.."J^n.:, .r D- 5 ;,', _ `""-."_k -wa p _.,,,,.: s ,; °G � U --.��. Hv 2 - 5cd 2 _ O -, p_ , s Y, �' lIRTU29v 4 : _ 1 r_..,r:�.-I�._.�L_.:�.; 1 " ::. _. - _.- __ :r I :: I 1 .._.. �. ,,..�I ." 1 .. ,a:._. ....,. s ,,,,,m,,.,_$ .�„" a:..,r,.::�_ - ,m:6:i , i1, +T r l _ " ., �,.. w ,..::.- _ s .W».,_.;., -,,,.. r,„. ,,,�,.__.� °r°' PS -2 Ila I ” tr III 2 1 _-;_- - �� .. - ALCOVE v LP 2 , . _ rt, _ :-. ?e ..... _. " _'__— 2 ,. : e .:r L r ^ : .. : a ,;a LP 2 v ,:I. V _ ; ,..::: , ,', " DAIRY .,, P _ .:. oI:",, I,". 75cd _ _ '75� €,1 _. ❑ LI . , �,, , : s c �L sl O „ PS _2 --.._,._.._....-, GQQLEIR S g-, ed'.t Hv PS t Ps , SMOKING-- D- B r i11 __u >: _ 6:,:w_,; - ,,., ,,,�...�� --r_"'.,tlk'...., .- . -` �. .r,e`._''- _ , D- 2 vr'`.y:� O ❑ _ 2 f -I _ -' ,y - I It I,ri V LP 1 RTU36 LP 1 HV ,�.'.. _- PS 1 5cd L" ..w., .,,.,r,. r,l WOMEN - ! ! i. , 1: , 1 !/�..I: >,:. I•.. 9: TRAINING III 0 O _ R Ai 1 ..I , - D 5 -..... LP 2 O rl I ,. , -: ...�: ,,.-....,._ , _ ,,.�, , „ �: '::� „ ..." :.:»e.: �. - ,.:,:� - , ,. E _ ❑ ,.;.., - _i +I A .f u; I , n., E _. D s - w.,__.._ _BREAK ROOM v C P b, Ps 7 :"R -�,:.- - «. . ,,;n HV .. } 1 , i , � -; '-- 1-..:-.,_�I , :� RTU28 !, iii �_ _._.:.__..�_..,,,_„_-__p_r"_____".....,_........... ..-`------,-__,_.__...,..___'---- ,...I ld s IN. -`.,..,I Iti _-mi ROOM x ROOM D- a - ❑ r I, ` r I, w Ps- 1 ,' " .,I- ...�; ,.�..r.. r' , , O II -.--.a.�... - .,, ,lh �... _-. _ , ,p�q - : - IC° D ,,.11.:w Il , ,,::,:.: ,".:.':w:, , I: 1 . t �' 1 ` ( G O ' I p_ip 75cd _ _ 75�d E.,---„ ".:I FAMILY :; 5' Q : It PS- 1 ,(v . :,I I, 4 LP 2 , i " Is ,:. II O ! " w .:, y� ❑ PS 1 1 :-.PS 1 %I" V V PS 1 J , :.- e�,E I p:f tr' I - ,,,.,__ PS- 1 Ill ALGQVE - I - .1 1.... a ! , HV LP- 1 : LP- 1 V tf"W�I PS- 1 PS 1 PS- 1 75cd TOILET LP- 2 ,;.: } V _1 LP- 2¢, ��t.:4 -F H D 12-sx = _ -'+`, Fay •„H +:' HV ul:Ii J NIN O O - P - LP 1 ,: PS- 1 It -". _ ;•. D -t 0 . I s 1 - - ,'' � � _ l ' � - - LP- 2 Q II, 15cd,!; PS 2 w D- g p_ q JANITOR a E LP 1 _ LP -2 D 9'I'''..a_, i5cda L - - ''.. w ;Ii ---. ❑ ----__._ .__- I s.. - V MEN ' �:. ,; :-, , _ �.:�_' �_ r -.l ,-.' _ R::: _ _ - D-13 I ._ D 2 LP 2 O , J ,, : ..: :.< r --'-.> "I €'ter _u' ,"` V --2 [r I,- , f I :' ,>. 1 a IY ut _. ' _ �., :J c °�.- ! _ 'a moi;_ p HV D- 2 V T .I , 4�d , r V -, :_ ,a' uv.,,,�'' � :.. _ �,_�..�- :..�:�.,. ':I i d .`- - _", :.D_ 3 _...-- - _ I..._....... _...... _ ..,,,_ ._11 NN. v 3 _. – - - --- - - — - --- -_ ._.-- - --- Hi,m..m .m:,,,ue,", ,m.z,,,�+.v..,.- _va<�a,:aia,.,:Fs } a. ..x.,.:�.,�aad, e _a,,,:.�m,,,wdr.,:, ,. ,...,. .�_. :-_ �,.,. owo.:m 1'.:,"ml n uew„m.�. .-_-ul�m..,wue_ 'muA6:.:mm..,mpo u_a"uml. ra,�:v.awv':C-N.m, a i'@'ui.,...w,,.-.��� y _.' wmMluu:r,n:.iFm', va xxl:Ysioum: rm�v�,f.:,s.-ea:�e.. ....,-�,....ta :-. -. -. ..�-�._.>._ _.___— - max..— -.e..,.,. _ _.,.. ,... _ _.- _ O 5 PS 3 MANAGEMENT I LT❑ D t ;' V OFFICE O H iIll . ll U NPS #3y__ IO I a PS 8 HV 0 u---=� , � NPS #4 I I I p 5 PS -8 I PS -8 ' L l LP- 2 LP- 2 + I EDC3 ,5cd In _, . D 4 D 3 !t ❑ I �: , M --STOCKROOM PS 3 0 ., 0 0 HV VO art yT 0 © b ©V t I 75cd MECHANICAL LP 1 PS 3 PS -3 i Ps -3 PS -3 PS -3 PS13 PS -3 PS-3PS-3 I PS -8 - ,8 V - j. ROOM I _D 2 D 1 D- 2 D- 3 p- 4 p_ 9 D 6 D- 7 D- 8 D- 9 I p_ 6 ' D I2 O L___ _.__- I '_. _ N L,. CUSTOMERi. _ _ 1 Z 1 - u�ScHV PP 8 u LLWAY r- SERVICE z IL G D 1 r '� G ,' I I I I -''-=i n I 2 2 I (" r ,. F __ _ _.. _.. .,..,. ...._ _ _ ._. _ - - _ - _ �- _ _ ___ -., __s,a _ _, _._.__.. _ .._, - _ _ _ _ �_,._. _. .._...., ...,.. -� _ _ - _ . _ ... try _ _u ... _. t -- RTU25 RTU24 AHU2 STOCKROOM) " RTU27 i i I I v ryye�-----� r3 tl', 75cd , _Z 1 1 1 : 1 r - O l:J a 75cd I I,. cv � I i "- P [ PS -8 L______J P5-$ 11l r 0 12� -ll RTU26 I Hv LP z P z P Hv JL �r. w r1gTP P�4 0 h-;? r• n 0 HV D- 7 D 8 i" S S I I PS- 4 5 , : P.._l , PS- 4 PS 4� ..-. ".":I LP 1 LP- 1 AN D- 3 0 0 0 - E.1 �V D 6 I'",11 " G I :j PS- 4 PS- 4 _ Ps- 4 LP 2 LP 2 - S 4 s❑ ❑ PS- 4 Ih 10 I L' I ?. :i LP- t p- 2 LP- 2 LP- 2 LP- 2 LP- 2 ,.,u G° al : O , I I. TIRE SALES ❑ LP- i LP -2 D3 p- a - D- 5 D- 6 ❑ k , ,_ D- i p_ 2 , p_ 1 D- 7 1 _ co .I 0 75cd ,' w I � I i J J: a PS- 3 t i u 1. I yl I 1 Cr , '1= I: O w LP- i - lI U .I..., I ' __ ,._ I u -a— ._, -11 110 - O I 11 .(/��) 4 WF =Il---: ,::,"^''t,,:=�,_ - _ v I -tea''+� - I Ps- 8 LP_ 8 _ illy "' i � I � (I IE rw .- .. ';i I O _ SALES © D= 8 \J r_ _ I 0 0 ; 0 HV D- 4 D 5 I_ li II II 't.:.11 C-,' r" _. °i' _ m Pp- j i PS- 4 PP- 6 PP -1 I a I i PP- t PP- 1 PP- 1 I PP- 1 - FOOD FREEZER SEAh ry m i, ii...„:�, I w i fl"I ❑ ❑ I r ° ° ❑ , ... _.,.___ .=, .1:��: D- 5 I p_ 3 D- 7 i D 8 RTU 21 D- 7 e D 6 D 5 I D- 4 II 1 1' >I, 'I O c:. -1 _� 1 i MCft i = _ _ .�,,,� tilIi r -, I I HU'J I I I _z_ I r -NNk U1,,J�TYP HV AFI 10 1 ,. _� !:. i4 . I U N I RTU20 O �1 ,u , r i I , ,J S 8 I . 1 I z 2 1 21 I' I GROCERY SALES LP , wNJ 1. 1 Ill I Z I I L -------I I ' S D 1 RTU22OL 1 I AN I I I I , I --- _ -- --.t,..------- _ --- ----------------- --- --- ----------- ---- -----------._..--- ---- -- - --- --- - --- - _._ _—_ _..- _ _ HV 0 0 U v PS --3 771P wl -w- -"9:— _.cw- _ _'- _'. °,'_ -- --*'- -__ - .. _ i_ _... O V4 LP- 1 v �, i FS- 6 I V I V V HV O PP_8 ...... PSVS ''" r , `_ D-1.2 5 0 LP-' I O 0 O �_ I ❑ - LP 1 — I � I... S 0 HV D 5 PS -7 - D- 3 _ D 2 r�;`•, v. a . D- {II D- 6 PO- 5 I! D- 6 D- I D- 8 i D=.3 '.,r ,I PS- 3 I - - ' -...-. Ill PS- 4 LP- 1 I 1 q, � 1,..-.=�.... 111 LP- 1 ❑ '� 3: I II I ,Illl D- 6 II . - : AHU1 I tt n .__ - _ v _.-__.. ,-, - y t ." i I I' I: i MNF p u , I IS I "'k PS -3 WP!'I I P V ': I: t I i'. ',, 'V; LP_ 1 HV , ; 9. c O fjI '' I i 1. "� r' D-11 , j j E-3-61 �I I I� I�-"�'/�` ! HV V - n O QPS 7 -.__ _ ( lJ 1 0 0 I i i �q PS -5 Ig LP- 1 PS 1 O �J ill ill i I I PS- 6 PS- 6 '4 PS- 5 I LP- Z l PS_ 5 1 D- 1 LP- 1 z PS- 3 PS_ 4 PS- 5 1 LP- 2 I LP- 2 LP- 2 14i"°" ..I LP- 1 - LP- 1 I LP- 1 I : D- 4 1 D- 3 D- 2 p_17 LP -2 ' __ D 1 NPS N7 _. v� D- 7 p_ 5 D-12 I I i D-12 lI I NI W OUTSIDE BAG 11 ^ MI ; � I , __,q INSIDE SALES I 1 1 Z 1 z 1 I I I ,, NPs #8 F GOODS ll I I � ; 1 --....-.._— .............. _- - -._..._...- - -- --WPId11� r N RTU18 RTU17 Ik I 2 1 "4- ..._...--- - --- - _ C. �J I: Ps- 3 v' z I ! I I 18 EDC4 I !I P- t q I Hv RTU16 - _'Ii D-10 _2 X11 p L Ps -6 I i PRODIUCE 1 ill-+il' RTU19 I LP- 1 I I '_: I _V I Ii it D- 3 Ps- 6 Ps- s Ps -7 EEP Ps- PS- 6 III ... :I V LP- 1 V LP_ 1 V LP- 2 I HV ! 0 'L% p_ 2 „- I,•P- 2 L _. a D ii m: 11 z 0 © I, 0 O °- 2 0 D- t O °- i POS- 5 f 0 PS- 7 HV § 1,�,. a~ II N:I I I .L ;,. s. LP- 2 : :- ': O .: _. - I ora ,_-I__ _ - --::.- - _...._ , , . - , ._. ...._ - _.... _ _.. , __... . .-__ - ___ -_ _.� �`____ .. _ ,- _ ._ . _ _ _.,-,_- _ _ _ —.. _ _- ., _ _..�_� _..... _._ __ s_.__ - _-___, — _ -..-.-_, ,_ _ _ ,.,__— _ — _ _ _ ..-_-,.,. _ - __. - y,, . PP- 4 RS_ 4 =, �. ,,_ LP- t-,::'.7--rE; 4'>.�, p i'w'=:ri ..� _ ,_. _ D-10 _. _._. LP_ 2 _ ®.�. ®._ _ �._.: _ -.._.,� _ m m:Y..l ¢- 7' I....:.p. �•,., - w. LP 1 '�--__-.u._._h , -,...-.___.__ _.4,.� ..._ _ °. fid -_ ,.:,..- Y _ L_,.` _ I _.:,.:.,:... 1 :2 l G H- 6 PHARMACY I I RTU15� CP -SA J PS- 3 ri It PHARMACY L J TOILET - ` ""'""°`� v iJ ' [I` D- 9 HV !. ...: $ _ NN _.. s.. . PS- 5 I ! ,. ,,.e-aNa '"7 P5- 7 11 igP i ❑:. v. i - AlSct -- -- - -----_-_.- -- --- -- --_lli_- --- g- -- --------------------- •`> , i-.....,,:-.. N11_,.,_.w.,_,::�-,--..,-.1,:,:u:___ _�T _ € II; F rr�'. LP1 :I. ❑' _-------`" _-.., ..-, .. _;iN- _- ,, _-.�, _4 .. ,.-.-_ .__ ,....,._ _._a,...., ,:,::_,_. �__- ` _ IF r ""'"'�_'-"":.. "^: r IIsi rl D-10 HV I. '. : ._,.....,.."..._,.., ..,__ItYP..-a ."._.,. ....W.:.:..,.:.::._,-.. ...,..W W,..YYB.....:...__. ....-_�, ,: "..,.. .. ...:.,_... . �._t_T_-.. ._:._..�;_,.,� , .... ... , -.... ,,,,, _-. ,-.,-.,._._,'_ ❑ : , / ": i 4 C, .r.,..,.,_.. -...u: - -y.. `Z'. T11 s N,. ,,.T!�^Y-..y, - , D , -_ B. 6 L _......._....I '.".III a}.JI.,` L:... `:. :-.€':. r I i€ __ I ium, v '__-__,,-•t.--.Ii ! I; 75cd PS -5 PS -5 FUTURE I -I i iRTU7 i i f PINING ARE SA �� / a J O { 1 Ili: II . , ❑ �f 1:,, ,.,V I Lp_ i BANK O p I PS -5 I ERVICEI, DELI I_.,.. -z _..IRTU2 75cd L CHILDREN "._._ `W' I7INGHV LP -1 III o w,._..._�� , L_J L -J ! Hv LP -2 GR VESTIBU v:�l' riinra---1_:i a-., _.i I d. PSI 1,- 3 PS- 4 I y I . ,I':".,,.,m,� i O _ 2:€. D 3 ,�- ,+ I_. le lv r' _ __ ,t _..,.. _? •: D 7 ;: , PS -5 �' - ..-..-. .-. RTU6 D_ 9 75cd l""" I, I ...Fr. 11 11 it"., �:.I.,111xNi:1 I"i:;"^d..-: V 1 1 _.I �'W's" 1PjRODU1'yt III ---__-,I, „ R, 11 LP- 1 LP- t : i CAMERA =i , ,.I-, `------ _.:;._. i rr o w ,. ❑ 1 ... - - N.FAMILY ,.- HV LP 2 '5 P p .. _. -, D 8 D 8 , - .: .:.... ,. _ ... _;. _P PS- 5-_ _-. 1 5cd O ,'€ ' - .mac '.� I, ! ° �QQL�4,R_I'i `OM i�ESTBUfF- D- i L> TENANT€ Hv - LP -2 75cd.';. DELI PREP ;I S'? CAMERA _ - q P- i 75cd 75cd SALON Q - y --. -.. I, OPTIC L1. L Hv Hv Hv I SPACE' Ps -7..- r �'v BAKERY t _,,, ,... w -r EDC2 _-_ v D- t COURTESY r g , _ :,; _ _ I r_ ❑ ❑ O O PS- 5 _ ��_ ., 1 2 1 SALES i5cd V V LP 2 1 2 1 .. [r .�-r.'°: D 4 1 PS -5 DESK Ps -s RTU41 ; p_ 6.:...a ,t,w w LP -z BAKERY PS- 5 15cd 12 I v P_ . Ps- 5 PS 5 LP 2 li Ps- 5 I z I BAKERY/DELI FREEZER ®L p_ 3 UTILI Y Lp- 7 ❑ -.. L 1 : .. L_J : : ,., it , V DELI 3-- _._,E: 1 HV :, rLi)IINTING _ LP Z D- 5 I. LP -2 ,_ __.� _�' - Ca,.1: ..t. s"r ,•,..i.,_ I.. �, :' LP RTU13 D- 6 SASH PS j- D 2 _ _ UTI! ITY - _ RTU3 I r t .- ... 1, ._. r , I i! -: ,,,.75cd. � " °_ ,. ,: D- 8 a r_ UTILITY , S4 ,, ,LAB LP t D 3 D 4 _k_. D 6 HV yy - I: . _ ,.____ -- -- - - - QE 1 _ { Il!_ It L r __._, _ .... _ :,..., :_,. . _ :..V. § . ___ ,._Ey rr 5-1 1. __,,, mm p_ 2 BAKERY I..,,-- W OUTSIDE LIVE v MECHANICAL- PP-� RET ST RETURN D- 7 �' EQUIPMENTS COOLER B GOODS D- 4 , WAITING STORAGE 75cd11 P i -1 ( EDC3 I: CART ❑� 15Od AREA PS -5 EQUIPMENT , C 5 Q P- UTILITY STORAGE I L 2 U L i, - - _-_ -I \ EXAM EXAM .' D- $ _ a a_. - . r , _. ,., _, ., ,„..-.._ ,. - , _ -_, , . ...., :. - .-_a: , .,. _ :o. - - - - `may- - - - _.-. , _ _ _ A i. _ _ 1! r6.,,,,.... ,,,y , 0 I 1 oNTacr �z l 1 ,_.-, ,. .._..., :',:1 I APPROVED FiLE CQPY I SALES 4 NPS #5 - I I • REVIEWED FOR CODE 1 i - COMPLIANCE I 1 I NPS #6 i1 'I • SUBJECT TO FIELDiNSPECTI i ELECTRONIC FIRE PROTECTION PLAN Date: J Zt 0'a Signed:_, 1 I” - 20'-0" it 0 oa �o� z oow a wi-o`Qo v, =-z ttQO O�0 �2w��s wc' Q JJY L_ �^-F O� rxO�Z�a'^z F¢U w��zr a, O Jaz joa Wzoaz ozz ,v- az a Q 3a �'1%�w wa O�V2�Q: � XZ - w wwwWa�W w 93gY'NVS,,- ~ Nvio zo ¢O�ua � o7 gaa�W¢vwia¢�a, Ill W -1rl -1- N ® CU r7 ,_4O z l O Ei � a, 4"FW .- IC r ' L7�11 W P. _Y W }}�. YY W e n ,,,, `�. � a Za Z O a S I,; W8ll0 - �-4 ow J .0 D N Z :1- O U w C17 Ill W -1rl -1- N ® CU r7 ,_4O z l O Ei � a, AV IC r ' L7�11 �./ F-tlllt`tlll4 W CQ DOCUMENT DATE: 10/28/04 Oo O 2� �?�_ U) col C� :1- w C17 ,�__ m O (ISSUE BLOCK I CHECKED BY: KT DRAWN BY: AV FI A LE NAME: E FPi PROTO CYCLE: 062504 DOCUMENT DATE: 10/28/04 NICET LEVEL 3 KEN TOCKSTEIN, ET FIRE ALARM SYSTEMS CE/RTIFICATION NUMBER I . i`0/2 a ELECTRONIC FIRE PROTECTION ppp PLAN 9 ;I IEE- FFA FIRE ALARM SYMBOLS LEGEND FIRE ALARM CONTROL PANEL POPIT MODULE CPU MANUAL PULL STATION PT RADIONICS 9412 SYSTEM SENSOR WALL MOUNT RADIONICS 0461 WATERFLOW ALARM PRESSURE RADIONICS D9127U WF HV HORN/STROBE LIGHT P1224MCW. CONTROL ANNUNCIATOR SWITCH (PROVIDED BY OTHERS) CP -SA RADIONICS 01256 75 cd UNLESS OTHERWISE NOTED. COOKING HOOD SUPPRESSION DRY NORMALLY OPEN RADIONICS D1257 ANNUNCIATOR O SYSTEM (POINT OF CONNECTION ' THL, HIGH/LOW AIR SUPERVISORY SWITCH { CONTACTS SA ONLY). SYSTEM SENSOR WEATHERPROOF (PROVIDED BY OTHERS) ❑V WALL MOUNT STROBE LIGHT 51224MCK. WATER FLOW INDICATOR SWITCH __ END OF LINE RESISTOR / NPS #X NOTIFICATION POWER SUPPLY SYSTEM SENSOR CEILING MOUNT WP 75cd UNLESS OTHERWISE NOTED. (PROVIDED BY OTHERS) DEVICE ALTRONIX AL802ULADA O STROBE LIGHT. SC24115W. 115cd SMOKE DETECTOR UNLESS OTHERWISE NOTED. SPRINKLER SYSTEM CONTROL VALVE 0 REVISION NO. X O2 DETECTION SYSTEMS SYSTEM SENSOR WEATHERPROOF SUPERVISORY TAMPER SWITCH DS284 SYSTEM SENSOR CEILING MOUNT WALL MOUNT HORN/STROBE LIGHT (PROVIDED BY OTHERS) N.O. NORMALLY OPEN HV HORN/STROBE LIGHT. PC24115W. WID HV P1224MCK. 75cd UNLESS OTHERWISE PS -POWER SUPPLY ASSIGNED TO WP WEATHERPROOF DUCT SMOKE DETECTOR 115cd UNLESS OTHERWISE NOTED. NOTED. ASSOCIATED CIRCUITS. (POINT OF CONNECTION LP -LOOP ASSIGNED TO ASSOCIATED r - - - - - - - - - - - r -, ONLY AND PROVIDED BY ALL NAC CIRCUITS WILL BE 12 O I SYSTEM SENSOR WALL MOUNT POWER SUPPLY. 2 OTHERS- REFER TO PLANS V STROBE LIGHT S1224MCW. 75 cd B 10" WATERFLOW BELL (PROVIDED D -DEVICE NUMBER ASSIGNED TO AWG. ALL OTHER FIRE ALARM FOR EXACT QUANTITY OF UNLESS OTHERWISE NOTED. O AND INSTALLED BY OTHERS) ASSOCIATED LOOP. WIRE WILL BE 18 AWG DUCT SMOKE DETECTORS w PER UNIT.) OCTAGON Ll BACK _T -BAR BOX DR OP TILE �:.EILING // -- GRID DROP CEILING) TILE DO NOT INSTALL WITHIN 3' OF ANY HVAC SUPPLY OR RETURN DIFFUSER SMOKE DETECTOR FLUSH MOUNT DETAIL -� SCALE: NTS 4" X 4" SQUARE CONDUIT BOX TAIL WALL MOUNTED STROBE AND HORN/STROBE /ICE MANUAL PULL STATION 80 TOP OF DEVICE TOP OF DEVICE NCI ANNUNCIATOR 48" 48" PT PT PT 3i 0 0 0 0 0 0 0 0 DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR RTU #38 RTU #37 RTU #36 RTU #34 0 01 10Ql0 Ql 10Ql0 (Dl 10(Dl0 0 DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR RTU #24 RTU #25 RTU #26 RTU #27 RTU #28 RTU #29 RTU #30 0 Ql 10QlO Ql 10Ql0 (Dl 10Ql0 O DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR RTU #22 RTU #21 RTU #20 RTU #19 RTU #18 RTU #17 RTU #16 0 Ql 10(Dl0 Ql 10 010 01 0 0 0 O DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR AHU #1 AHU #2 AHU #3 RTU #1 RTU #2 RTU #3 RTU #13 PT PT PT PT PT PT PT PT PT PT TYPICAL DEVICE MOUNTING HEIGHT CALCULATIONS 75cd 75cd 75cd 75cd 75cd 75cd 75cd 120V A.C. SCALE: NST COOKING HOOD COOKING HOOD GARDEN V GARDEN HV V HV V HV HV V SA SUPPRESION SUPPRESION CENTER GARDEN CENTER 75cd 15cd WP 15cd SYSTEM #2 SYSTEM #1 DRY SYSTEM CENTER DRY SYSTEM VALVE VALVE 0.0180 SUPPLY 0.1000 WATERFLOW DRY SYSTEM HIGH/LOW TAMPER TAMPER RISER #5 RISER #4 RISER #3 V D1257 ANNUNCIATOR V 0.1040 TAMPER LOCATED #7 #6 1 CP -SA 0.1200 PT PT V PT HV v v v PT 0.0500 PT v PT n v PT v n v PT LOCATED 0.802 PT 1.365 PT TOTAL BACKUP BATTERY PROVIDED = 28.000 AH TOTAL BACKUP BATTERY REQUIRED = 19.359 AH TOTAL BACKUP BATTERY RESERVED = 8.641. AH PT p PT 0.175 I POWERED BY A LOCKED ANO DCIRCUIT BRANCH CIRCUIT L -------- CENTRAL STATION II YY AS PER MNFR'S REC, ABOVE EDC #3 EDC #4 COURTESY COURTESY CPU DESK DESK RISER #1 RISER #2 RISER #3 RISER #4 RISER #5 RISER #1 RISER #2 EQUIPMENT CPU 120V A.C. T CALCULATIONS 75cd 75cd 75cd 75cd 75cd 75cd 75cd 120V A.C. 15cd HV V V HV V V HV V HV V HV HV V AL802ULADA HV D192C NAC MODULE V POWER V 75cd 15cd WP 15cd POWER 15cd 75cd 75cd 75cd 15cd 75cd 15cd 75cd 15cd 0.0180 0.0180 SUPPLY 0.1000 D1256 ANNUNCIATOR 1 0.1040 V V V D1257 ANNUNCIATOR V 0.1040 HV LOCATED PS #2 D8132 BATTERY CHARGER 1 0.1200 0.1200 0.1200 0.1200 V 1 HV v v v n v 0.0500 v v 75cd n v 75cd v n v v LOCATED 0.802 PS #1 1.365 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.802 X 24 HOURS = 19.246 AH TOTAL AMPS USED IN ALARM: 1.365 X 0.083 (5 MIN.) = 0.113 AH TOTAL STANDBY BATTERY REQUIREMENTS = 19.359 AH TOTAL BACKUP BATTERY PROVIDED = 28.000 AH TOTAL BACKUP BATTERY REQUIRED = 19.359 AH TOTAL BACKUP BATTERY RESERVED = 8.641. AH c p 0.175 0.175 TOTALS 0.118 TOTALSTANDBY 0.080 o EQUIPMENT IN EDC1 TOTAL AMPS USED IN STANDBY: TOTAL AMPS USED IN ALARM: COMPUTATIONS 0.080 X 24 HOURS= 5.216 X 0.083 (5 MIN.) = TOTAL STANDBY BATTERY REQUIREMENTS = 1.920 AH 0.433 AH 2.353 AH HV 2.292 HV V 120V A.C. LOCATED IN EDC3 120V A.C. LOCATED IN EDC3 ALS02ULADA POWER SUPPLY PS #3 AL802ULADA POWER SUPPLY PS #4 75cd 75cd H V VP 15cd 15cd 75cd 75cd WP WP WP WP WP V V V HV HV V HV V HV V HV V--� LP2 V nv v I nv v nv HV v V nv HV vV - LPl WP CALCULATIONS DEVICE TYPE 75cd 75cd 75cd 75cd 75cd 75cc 120V A.C. 15cd 15cd V HV V HV V HV D113 BATTERY SUPERVISION RELAY AL802ULADA 0.0300 V 0.0300 HV D192C NAC MODULE V POWER V 75cd 15cd WP 15cd HV SUPPLY V 0.0752 HV V HV -- LP1 0.0180 0.0180 AL802ULADA 0.1000 D1256 ANNUNCIATOR 1 0.1040 V V V D1257 ANNUNCIATOR V 0.1040 HV LOCATED PS #2 D8132 BATTERY CHARGER 1 0.1200 0.1200 0.1200 0.1200 D8125 POPEX MODULE 1 IN EDC1 0.0500 POWER 0.0500 15cd 75cd 75cd 120V A.C. LOCATED IN EDC3 120V A.C. LOCATED IN EDC3 ALS02ULADA POWER SUPPLY PS #3 AL802ULADA POWER SUPPLY PS #4 75cd 75cd H V VP 15cd 15cd 75cd 75cd WP WP WP WP WP V V V HV HV V HV V HV V HV V--� LP2 V nv v I nv v nv HV v V nv HV vV - LPl WP 120V A.C. LOCATED IN - EQUIPMENT ROOM 120V A.C. LOCATED IN EDC4 120V A.C. LOCATED IN EDC4 AL802ULADA POWER SUPPLY PS #6 ALS02ULADA POWER SUPPLY PS #7 AL802ULADA POWER SUPPLY PS #8 V HV V HV V HV V HV 75cd WP 75cd 75cd 75cd 75cd HV V HV V HV HV V V HV--�CP2) 15cd 7 RISER DIAGRAM WP HV 9412 BATTERY CALCULATIONS DEVICE TYPE QTY 15cd TOTALSTANDBY CURRENT 15cd 15cd 75cd 15cd 15cd 120V A.C. 0.3000 0.5000 0.5000 D113 BATTERY SUPERVISION RELAY V 0.0300 V 0.0300 HV D192C NAC MODULE V 0.0200 V 0.0100 V HV 4 HV 0.0024 V 0.0752 HV V HV -- LP1 0.0180 0.0180 AL802ULADA 0.1000 D1256 ANNUNCIATOR 1 0.1040 0.1040 0.2060 0.2060 D1257 ANNUNCIATOR 1 0.1040 0.1040 02060 0.2060 D8132 BATTERY CHARGER 1 0.1200 0.1200 0.1200 0.1200 D8125 POPEX MODULE 1 0.0500 0.0500 POWER 0.0500 15cd 75cd 75cd 0.0235 75cd 0.0376 LOCATED IN SC24115W @ 115cd 6 SUPPLY 0.802 TOTAL ALARM 1.365 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.802 X 24 HOURS = 19.246 AH TOTAL AMPS USED IN ALARM: 1.365 X 0.083 (5 MIN.) = 0.113 AH TOTAL STANDBY BATTERY REQUIREMENTS = 19.359 AH TOTAL BACKUP BATTERY PROVIDED = 28.000 AH TOTAL BACKUP BATTERY REQUIRED = 19.359 AH TOTAL BACKUP BATTERY RESERVED = 8.641. AH c p 0.175 0.175 TOTALS 0.118 TOTALSTANDBY 0.080 o EQUIPMENT NOTES: TOTAL AMPS USED IN STANDBY: TOTAL AMPS USED IN ALARM: COMPUTATIONS 0.080 X 24 HOURS= 5.216 X 0.083 (5 MIN.) = TOTAL STANDBY BATTERY REQUIREMENTS = 1.920 AH 0.433 AH 2.353 AH HV 2.292 HV V V HV 0.262 HV V V 0.434 HV HV V HV -- LP2 ROOM Na- N PS #5 O J J W TOTAL ALARM 0 W TOTAL BACKUP BATTERY PROVIDED - 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.411 AH TOTAL BACKUP BATTERY RESERVED = 4.589 AH 120V A.C. LOCATED IN - EQUIPMENT ROOM 120V A.C. LOCATED IN EDC4 120V A.C. LOCATED IN EDC4 AL802ULADA POWER SUPPLY PS #6 ALS02ULADA POWER SUPPLY PS #7 AL802ULADA POWER SUPPLY PS #8 V HV V HV V HV V HV 75cd WP 75cd 75cd 75cd 75cd HV V HV V HV HV V V HV--�CP2) 15cd 7 RISER DIAGRAM WP HV 9412 BATTERY CALCULATIONS DEVICE TYPE QTY STANDBYCURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT 9412 CONTROL UNIT 1 0.3000 0.3000 0.5000 0.5000 D113 BATTERY SUPERVISION RELAY 2 0.0300 0.0600 0.0300 0.0600 D192C NAC MODULE 1 0.0200 0.0200 0.0100 0.0100 DS 284 SMOKE DETECTOR 4 10.0006 0.0024 0.0188 0.0752 D928 DUAL PHONE LINE SWITCHER 1 0.0180 0.0180 0.1000 0.1000 D1256 ANNUNCIATOR 1 0.1040 0.1040 0.2060 0.2060 D1257 ANNUNCIATOR 1 0.1040 0.1040 02060 0.2060 D8132 BATTERY CHARGER 1 0.1200 0.1200 0.1200 0.1200 D8125 POPEX MODULE 1 0.0500 0.0500 0.0500 0.0500 D9127U POPIT MODULES 47 0.0005 0.0235 0.0008 0.0376 TOTALS SC24115W @ 115cd 6 TOTALSTANDBY 0.802 TOTAL ALARM 1.365 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.802 X 24 HOURS = 19.246 AH TOTAL AMPS USED IN ALARM: 1.365 X 0.083 (5 MIN.) = 0.113 AH TOTAL STANDBY BATTERY REQUIREMENTS = 19.359 AH TOTAL BACKUP BATTERY PROVIDED = 28.000 AH TOTAL BACKUP BATTERY REQUIRED = 19.359 AH TOTAL BACKUP BATTERY RESERVED = 8.641. AH WORST CASE WIRE VOLTAGE DROP CALCULATION CIRCUIT: 7-1 TOTAL AMP. WIRE LENGTH (FEET) AWG. CIRC. MILS VOLT DROP TANDBY CURRENT GARDEN CENTER DRY SYSTEM TAMPER SIZE X GARDEN CENTER DRY SYSTEM HIGH LOW 2.828 470 12 6530 4.394 APPROXIMATE TOTAL WIRE: 470 FT. TOTAL VOLTAGE DROP IN CIRCUIT: 4.394 VDC TOTAL PERCENTAGE DROP IN CIRCUIT: 21.54% OPERATING VOLTAGE AT LAST DEVICE: 16.006 VDC MINIMUM OPERATING VOLTAGE: 16 VDC BASED UPON A 24.00 VDC CIRCUIT OPERATING AT 72 DEGREES CIRCUIT: 7-1 TOTAL VOLTAGE DROP EQUALS THE SUM OF ALL INDIVIDUAL VOLTAGE DROPS PER EACH SIGNAL CIRCUIT SEGMENT. CALCULATIONS ARE BASED ON THE FOLLOWING FORMULA: DEVICE LOAD(AMPS) X SECTION RUN(FEET) X RESISTIVITY OF CU(21.6) CIR. MIL.OHM/FT. OF WIRE GAUGE POINT TO BE ANNUNCIATED AS FIRE ALARM POINT TYPE SUPERVISORY ALARM GARDEN CENTER DRY SYSTEM WATERFLOW X TANDBY CURRENT GARDEN CENTER DRY SYSTEM TAMPER ALARM CURRENT X GARDEN CENTER DRY SYSTEM HIGH LOW SC24115W @ 115cd X RISER #1 WATER FLOW X 6. RISER #2 WATER FLOW X 0.325 RISER #3 WATER FLOW X 1 RISER #4 WATER FLOW X 0.205 RISER #5 WATER FLOW X S1224MOW @ 75cd RISER #1 TAMPER CQ X RISER #2 TAMPER 0.160 X RISER #3 TAMPER S1224MCW @ 15cd X RISER #4 TAMPER P1224MOW @ 15cd X RISER #5 TAMPER X VALVE TAMPER #6 2 X VALVE TAMPER #7 X MANUAL PULL STATION X PC2475W @ 75cd SMOKE DETECTORS X 0.175 DUCT SMOKE DETECTORS 0.262 X COOKING HOOD SUPPRESSION SYSTEM X 2 ALL FIRE ALARM SYSTEM CIRCUIT WIRING MUST ANNUNCIATE A TROUBLE SIGNAL DURING OPEN AND GROUND FAULT CONDITIONS. ADDITIONALLY ALL OUTPUT CIRCUITS (HORNS/STROBES) ARE REQUIRED TO ANNUNCIATE A TROUBLE SIGNAL DURING A WIRE TO WIRE SHORT CONDITION. THE FIRE ALARM SYSTEM WILL BE TESTED BY THE OWNER'S REPRESENTATIVES TO THE CRITERIA OF TABLES 3-5.1 AND 3-7.1 OF THE 1999 NFPA 72, SEQUENCE OF OPERATIONS BATTERY CALCULATIONS QTY DEVICE TYPE QTY TANDBY CURRENT TOTALSTANDBY CURRENT ALARM CURRENT 2 w SC24115W @ 115cd 1 0.650 SC2475W @ 750d 6. 0.325 l - 0.325 SC2475W @ 75cd 7 1 O 0.205 0.059 In S1224MOW @ 75cd 3 CQ 0.160 0.320 0.160 4 U) S1224MCW @ 15cd 3 1.048 P1224MOW @ 15cd 1 0.059 0.177 PC24115W @ 115cd 2 1 0.382 0.217 z PC2475W @ 75cd 5 � = 0.175 0.175 0.262 O P1224MOW @ 75cd 2 3.815 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS= 1.920 AH TOTAL AMPS USED IN ALARM: 3.815 X 0.083 (5 MIN.) = 0.317 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.237 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.237 AH TOTAL BACKUP BATTERY RESERVED = 4.763 AH 0.217 DEVICE TYPE QTY F P1224MCW @ 15cd 1 TOTAL ALARM CURRENT SC24115W @ 115cd 6 0.116 0.325 wZ 00 1 c p 0.175 0.175 TOTALS 0.118 TOTALSTANDBY 0.080 o 0.160 NOTES: TOTAL AMPS USED IN STANDBY: TOTAL AMPS USED IN ALARM: COMPUTATIONS 0.080 X 24 HOURS= 5.216 X 0.083 (5 MIN.) = TOTAL STANDBY BATTERY REQUIREMENTS = 1.920 AH 0.433 AH 2.353 AH w 2.292 < 7.000 AH 2.353 AH 4.647 AH cn 0.262 P1224MCK @ 75cd 2 w 0.217 0.434 AL802ULADA 1 p p Na- N < Q O J J W TOTAL ALARM 0 W TOTAL BACKUP BATTERY PROVIDED - 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.411 AH TOTAL BACKUP BATTERY RESERVED = 4.589 AH I- W J Z TOTALSTANDBY CURRENT ALARM CURRENT Y g SC24115W @ 115cd w ° a CENTRAL STATION TO RECEIVE z n Y N Q P1224MCK @ 75cd SEPARATE &DISTINCT SIGNALS. Y w z ¢ 1 a 0.080 0.175 0.175 TOTALS Q 0.080 O 6.924 V TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.495 AH TOTAL BACKUP BATTERY RESERVED = 4.505 AH ": VaiUJ W QTY STANDBY CURRENT 1- ALARM CURRENT TOTAL ALARM CURRENT - SC24115W @ 115cd 2 D 0.325 0.650 SC2475W @ 75cd 3 0 0 0 O} O O Zp S1224MCW @ 15cd z Z Z Z It Z Z U 0 0 0 0Ln 0 0 P1224MCW @ 75cd 6 0.217 1.302 i F- P J 0.116 0.232 > 1 > 0.175 0.175 > TOTAL STANTOTAL > >w > POWER SUPPLY #6 BATTERY CALCULATIONS DEVICE TYPE QTY m TOTAL STANDBY CURRENT P= F- F- F a H- F= p 2.600 U U U U Z U U E)f 1 a a a a n a s TOTALSTANDBY 0.080 X 5.831 X TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.404 AH TOTAL BACKUP BATTERY RESERVED = 4.596 AH X X QTY ACTIVATES HORN/STROBE LIGHTS TOTALSTANDBY CURRENT ALARM CURRENT TOTALALARM CURRENT SC24115W @ 115cd 6 TRANSMIT ALARM SIGNAL TO APPROVED CENTRAL X SC2475W @ 75cd X �� X X 0.205 STATION ALARM MONITORING SERVICE 1 0.160 0.160 PC24115W @ 115cd 5 TRANSMIT SUPERVISORY SIGNAL TO APPROVED XX 1.910 PC2475W @ 75cd 4 CENTRAL STATION ALARM MONITORING SERVICE 1.048 AL802ULADA 1 0.080 0.080 0.175 1 0.175 TRANSMIT TROUBLE SIGNAL TO APPROVED TOTAL STANDBY 0.080 TOTAL ALARM 5.446 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0..080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 5.448 X 0.083 (5 MIN.) = 0.452 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.372 AH X CENTRAL STATION ALARM MONITORING SERVICE DEVICE TYPE X STANDBYCURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd ACTIVATES INDIVIDUAL RTU SHUTDOWN X 1.625 SC2475W @ 75cd 1 ACTIVATES BELL ABOVE FDC POWER SUPPLY #1 BATTERY CALCULATIONS QTY DEVICE TYPE QTY TANDBY CURRENT TOTALSTANDBY CURRENT ALARM CURRENT 2 TOTAL ALARM CURRENT SC24115W @ 115cd 1 0.650 SC2475W @ 750d 6. 0.325 l - 0.325 SC2475W @ 75cd 7 1 O 0.205 0.059 1.435 S1224MOW @ 75cd 3 CQ 0.160 0.320 0.160 4 0.480 S1224MCW @ 15cd 3 1.048 P1224MOW @ 15cd 1 0.059 0.177 PC24115W @ 115cd 2 1 0.382 0.217 0.764 PC2475W @ 75cd 5 0.080 0.175 0.175 0.262 1.310 P1224MOW @ 75cd 2 3.815 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS= 1.920 AH TOTAL AMPS USED IN ALARM: 3.815 X 0.083 (5 MIN.) = 0.317 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.237 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.237 AH TOTAL BACKUP BATTERY RESERVED = 4.763 AH 0.217 DEVICE TYPE QTY 0.434 P1224MCW @ 15cd 1 TOTAL ALARM CURRENT SC24115W @ 115cd 6 0.116 0.325 0.116 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS 0.118 TOTALSTANDBY 0.080 TOTAL ALARM 0.160 5.216 TOTAL AMPS USED IN STANDBY: TOTAL AMPS USED IN ALARM: COMPUTATIONS 0.080 X 24 HOURS= 5.216 X 0.083 (5 MIN.) = TOTAL STANDBY BATTERY REQUIREMENTS = 1.920 AH 0.433 AH 2.353 AH 0.382 2.292 TOTAL BACKUP BATTERY PROVIDED = TOTAL BACKUP BATTERY REQUIRED = TOTAL BACKUP BATTERY RESERVED = 7.000 AH 2.353 AH 4.647 AH POWER SUPPLY #2 BATTERY CALCULATIONS DEVICE TYPE QTY TANDBY CURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd 2 10/28/04 0.325 0.650 SC2475W @ 750d 6. O l - - 0.205 1230 S1224MCW @ 15od 1 O 0.059 0.059 S1224MCK @ 75cd 2 LLJ CQ 0.160 0.320 P02475W @ 75cd 4 0.262 1.048 P1224MOW @ 15cd 1 0.116 0.116 P1224MOK @ 75cd 1 0.217 0.217 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS TOTALSTANDBY 0.080 TOTAL ALARM 3.815 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS= 1.920 AH TOTAL AMPS USED IN ALARM: 3.815 X 0.083 (5 MIN.) = 0.317 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.237 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.237 AH TOTAL BACKUP BATTERY RESERVED = 4.763 AH POWER SUPPLY #3 BATTERY CALCULATIONS DEVICE TYPE QTY STANDBY CURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd 6 0.325 1.950 SC2475W @ 75cd 1 0.205 0.205 - - S1224MCW @ 15cd 2 0.059 0.118 S1224MCK @ 75cd 3 0.160 - 0.480 PC24115W @ 115cd 6 0.382 2.292 PC2475W @ 75cd 1 0.262 0.262 P1224MCK @ 75cd 2 0.217 0.434 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS TOTALSTANDBY 0.080 TOTAL ALARM 5.916 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 5.916 X 0.083 (5 MIN.) = 0.491 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.411 AH TOTAL BACKUP BATTERY PROVIDED - 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.411 AH TOTAL BACKUP BATTERY RESERVED = 4.589 AH POWER SUPPLY #4 BATTERY CALCULATIONS DEVICE TYPE _ QTY TANDBY CURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd 8 0.325 2.600 PC24115W @ 115cd 6 0.382 2.292 P1224MCK @ 75cd 1 0.217 0.217 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS TOTALSTANDBY 0.080 TOTAL ALARM. 6.924 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 6.924 X 0.083 (5 MIN.) = 0.575 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.495 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.495 AH TOTAL BACKUP BATTERY RESERVED = 4.505 AH POWER SUPPLY #5 BATTERY CALCULATIONS DEVICE TYPE QTY STANDBY CURRENT TOTALSTANOBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT - SC24115W @ 115cd 2 0.325 0.650 SC2475W @ 75cd 3 0.205 0.615 31224MCW @ 75cd 3 0.160 0.480 S1224MCW @ 15cd 4 0.059 0.236 PC24115W @ 115cd 3 0.382 1.146 PC2475W @ 75cd 1 0.262 0.262 P1224MCW @ 75cd 6 0.217 1.302 P1224MCW @ 15cd 2 0.116 0.232 AL802ULADA 1 0.080F0.080 0.175 0.175 TOTALS TOTAL STANTOTAL ALARM 5.098 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 5.098 X 0.083 (5 MIN.) = 0.423 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.343 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.343 AH TOTAL BACKUP BATTERY RESERVED = 4.657 AH POWER SUPPLY #6 BATTERY CALCULATIONS DEVICE TYPE QTY STANDBY CURRENT TOTAL STANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd 8 0.325 2.600 PC24115W @ 115cd 8 0.382 3.056 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS TOTALSTANDBY 0.080 TOTAL ALARM 5.831 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24. HOURS= 1.920 AH TOTAL AMPS USED IN ALARM: 5.831 X 0.083 (5 MIN.) = 0.484 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.404 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.404 AH TOTAL BACKUP BATTERY RESERVED = 4.596 AH POWER SUPPLY #7 BATTERY CALCULATION DEVICE TYPE QTY TANDBY CURREN TOTALSTANDBY CURRENT ALARM CURRENT TOTALALARM CURRENT SC24115W @ 115cd 6 0.325 1.950 SC2475W @ 75cd 1 �� 0.205 0.205 S1224MCK @ 75cd 1 0.160 0.160 PC24115W @ 115cd 5 - 0.382 1.910 PC2475W @ 75cd 4 0.262 1.048 AL802ULADA 1 0.080 0.080 0.175 1 0.175 TOTALS TOTAL STANDBY 0.080 TOTAL ALARM 5.446 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0..080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 5.448 X 0.083 (5 MIN.) = 0.452 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2.372 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.372 AH TOTAL BACKUP BATTERY RESERVED = 4.628 AH POWER SUPPLY #8 BATTERY CALCULATIONS DEVICE TYPE QTY STANDBYCURRENT TOTALSTANDBY CURRENT ALARM CURRENT TOTAL ALARM CURRENT SC24115W @ 115cd 5 0.325 1.625 SC2475W @ 75cd 1 0.205 0.205. PC24115W @ 115cd 5 0.382 1.910 PC2475W @ 75cd 1 0.262 0.262 P1224MCW @ 15cd 1 0.116 0.116 P1224MCK @ 75cd 1 0.217 0.217 AL802ULADA 1 0.080 0.080 0.175 0.175 TOTALS TOTAL STANDBY 0.080 TOTAL ALARM 4.510 COMPUTATIONS TOTAL AMPS USED IN STANDBY: 0.080 X 24 HOURS = 1.920 AH TOTAL AMPS USED IN ALARM: 4.510 X 0.083 (5 MIN.)= 0.374 AH TOTAL STANDBY BATTERY REQUIREMENTS = 2294 AH TOTAL BACKUP BATTERY PROVIDED = 7.000 AH TOTAL BACKUP BATTERY REQUIRED = 2.294 AH TOTAL BACKUP BATTERY RESERVED = 4.706 AH FIRE PROTECTION SUPERVISORY DETAILS z w � o¢ oo� co m oCYiw o "za w aF�C�oirwv,w goo ¢ a w 0�te cn�5-1 �IFo¢� ww5v aw �,. m��xo�zm p ww -v_la w¢KUr Q lnya��o z Ornw O3 V Z O N p N w m O O r Z Uai �oa �zpa¢z Za Q gi, N zzw,awo ln�z Awa J Ula. ttz.V� w ww�wo mow. .cm TNSI- Ln Nw zoo-ao¢c LnFin �d'z aozwrcwwDo a�w avl¢tt�a� JO (ISSUE BLOCK CHECKED BY: i DRAWN BY: Q�q ' Kx„YN FILE NAME: J a x PROTO CYCLE: 062504 DOCUMENT DATE: 10/28/04 Z ® Q O D (10z a O U ply JO (ISSUE BLOCK CHECKED BY: rl--a DRAWN BY: AV FILE NAME: EFP2 PROTO CYCLE: 062504 DOCUMENT DATE: 10/28/04 ® N O � O a ply LLJ CQ O CD u JO (ISSUE BLOCK CHECKED BY: KT DRAWN BY: AV FILE NAME: EFP2 PROTO CYCLE: 062504 DOCUMENT DATE: 10/28/04 NICET LEVEL 3 KEN TOCKSTEN, ET FIRE ALARM SYSTEMS CERTIFICATION NUMBER ELECTRONIC FIRE PROTECTION RISER PLAN SHEET EFP2 9 0.. DRY SYSTEM WITH GALVANIZED PIPING Cm120 0.20/ARElk 250 GPM HOSE Ke S_1 16 A.S. FLOWING REO'D AT CITY SUPPLY: 43.4 PSI 659.5 GPM (INCLUDING HOSE ALLOWANCE RWD AT BASE OF RISER: 136.4 PSI 409 GPM "PENDENT HEADS IN CEILINGS 10'-0" AND ABOVE TO HAVE EXTENDED 401 ESCUTCHEONS "PENDENT HEADS IN CEILINGS W-11" AND BELOW TO HAVE SEMI—RECESSED ESCUTCHEONS .425/2161, 250 GPM HOSE K- 25.2 12 A.S. FLOWING RE&D AT CITY SUPPLY: 37.0 PSI 1350.5 GPM (INCLUDING HOSE ALLOWANCE) REQ'D AT BASE OF RISER: 119.3 PSI 1130 GPM EIRE SPRINKLER PLAN - ZONE 5 3/321, = 1'--011 KEY PLAN N.T.S. 3ER 31_10 CALCULATION #6 N 500 GPM HOSE ll 11.2 m I 92 A.S. FLOWING n ? REQ'D AT CITY SUPPLY: 14.0 PSI O aD m & A 2499 GPM (INCLUDING 1405E ALLOWANCE) q Ril AT BASE OF RISER: �, 66.9 PSI o _ o " ? I i•S3B GPM 13 7 1$ DRY 5Y571?M WITH GALVANIZED PIPING m GAR IN CENTER 12015 PSI, 250 GPM HOSE 125.2 12 A.S. FLOWING REO'D AT CITY Si -13.0 PSI 41 1534.5,l (INCLUDING HOSE ALLOWANCE) REO'D AT BASE OF RISER: 65.5 PSI O 1205 GPM - _ C.120 ,�j, DRY SYSTEM o = pRY PIPE RISER RE: FP'4 = _ c3TORAO p GALV PIPE `M1 'M1 n _ ° b I M1 M1 ,M1 - ���- - I-10 ,•., v. g..9. In 9-0 1 � 1 N GALV PIPE � - - 9 -to r3.^ ^ o- 1 �M1 ,M1 83 'LM1 n �_ .. _tiD , ,n 8-4 3-] '�' 10-4 .L ] 1 1 1 O ,pc' 1 - �_" Ft b _2 9-1 x x "-61 I 2 ``� - • "� 2 3-3 6"4 b m 1 I � Rim JQ�G a �) �� , � , � � � ` 1 ��.71•�IIS 11 • 1� -- - •- -I � •� 1 A �� � � __ ,tom: DSPNOT BE RACE FROM DOOR TRACK Q I , Till t�3 23' I I I I 9-2 e�+ '_t po-t sol -� I� I♦— j°- � I I I I 4 h' -, .1, 3- 1 2 2-11 ^• �` I 1-11 4 t J .N_ .—_4 _•rRe�0F.l Or'�uD.l . A •N4,T'' I-O2N -" .N t� .pusT I' -I--IIt-1—Io'0I I-1-I_1"10N,I I _n°6I�- w1e0 1iI I -I rI5 �1I _tdI tsI -_�zI1-.l t_ja7NI� 7•i,cy�7vN I11I—o1 - 1� I-x� 1INI_bZ�1N It�1'0 1 '._N•I-I21 I- I I0 I I II RI 9I- I E,dIoiI oF 9 A -+ 5109�I -9 x1 0.1-{IT10 1 80I T}-IO� 0IY1 I'PNI1lI I -I 1 r -I- j—rI I -r 1 IU►rGIrL 1RI E4I- I 2X - RI F5._H I1I tI 0I i_ I I' II I I I I i 1I II 1Iri 9_0-1 II- i 1_II II ' I 1I 1 II I 1- II i i I 1 II f�I'-1I ►9I� i I0 1 jII 1 1 0I1 - II 1 I' I _bI I 1I 1 I I1.1N 1 iI_ t - I 2_3-' I {i I_ I-II..I►.i I.I 1yV 1Ir� � I I -j1 I II1 *1I I-•tI- 0 7 I1 .I0i�1b0-1o--I'j -1I -I—I?- o II--t—1 II i 11 1moiiI=i1 2i --I - z�I�I I Ii n^I-- • -� -moI 1 -I9I1-Ij- 1 io1i --tI � .ix.tI -_-II I _I,-�-3Ij �` -I 1 ' ❑ -1- I1tI_- ❑�I I I 1II II1� 0I tO�I 0 W1iI0I-1 rI 1I o— I I� �1 I Ii �rI- 1I1 I tI I1t I II `II_ -t0aI 1 _ I 1 09,aII❑0 -9Iy 0I 1-N`1�0�7I� I ' I 2 2 IN I 1ItI- 3I_fI r1 I( -rI14I 1_I14 1 2 I14 3 14'4t_ H-514 68 H1Hr17 I 1SIb s2 16 w ry I'�� d_- r^�� 811n� I 8ryI . 1ry I I-1 I 1tI02 1 n -0I 1.1I2 _ _— -1 0-007 � II( I _4 IiI-'I�I l !yI1I I i N , 2trr'- z Nf- l1 —• - - INGTWO SUMFIT. 4t_ -t 10' -ZONE 2 � w -10" Q'-4" 0-p 2n 1 .q t W 2 "ITCH DRY SYSTEM TO DRAIN 1 1 6 f0 DRUM DRIP A55E111Y 7R DRY PIPEVALVE 0 I 1 t - I 2 10 It 11-2 3RANCHLINES 1/2" IN 10'-Or14-0 I --lAINS 1/4" IN I0 9-10 DRY SYSTEM GALVANZhD 504 10 OR 40 PIPE $ FITTINGS L -i 4-66-10 ANO SULLSTITUTIONS !L2 #2 11-1113-0 .4252 20 GPM 1405E Ka 25.2 II 11-0 12A.S. FLOWING 12-4 Rl AT CITY SUPPLY: _tl 29.4 p51 1 LLWNCE) -10 t1-2 i 11-2 1512OGPM Pry (INCLUDING HOSE A 11 -x ZO n-TYPAN BASE OF RISER: A 17PSI O 5 REF TO H �1L5 Di 1063 GPM _13— PAR—to OT14 Ull � NC�E7AIL5ON FP 8-11 024INFOI SK E tot we LOW {T 7-6 I TYPI 1 ON sAg FL OR 1 A zrli _ I 2 1 i72 9W I p I 11-2 A- 0 1 4- 11-2I Nr2 1 cle, im »-x '° P -10 1- .,_I-2 910 .......... 23. 1 _ P................2 211 II 8 -it 71-2 1 1 1 p 23' 11-0 SALES 1 2 05ED I it -0 141-0 10 01 4-2e O I-1 0 1 wl o30 1 ip rz AUX DRAZON- 2 x AUX DRAIN/DRI DRIP ZON ZON------ — m 1:+ 1 00 If 1 FIRE SPRINKLER PLAN - ZONE 2 1$ PARTIAL ZONE 1 a/32" � 1'-0" ss BR TY4231 ® /0 5- WHT W/WHITE SEMI -RECESSED ESCUTCHEON TY9226 0 28 SiEPE S RR PENDENT - - -- ,� A roA - 9n' I CL8181 ISI �CEAL OF AU A P -1 SPK BELOW O/1DOR, .-_- E I DRAIN PI x HEAD CAGES RFW[ItED s to 8-4 i 6 DO NOT BRAGS FROM DOOR ACK 1 I ....... ... ro I 1 nn 1 2IG NF rifgl- U ti w N ot O - A TLE PIT 3/32" = 1'll A ) .��_---- A 795 8' qb' g• 10' 12 14' 16' 18' 20' 22' 24' 25' z8' 30' 3�' 34' 36' 38' 40' 4 dAFLOW TOTAL.._ EIRE ;CREWED PROTECTION INC. 921-91N P.O. BOX 680 RANDOM 9D. 5, KEY PLAN IIIIIII N.T.5. NAL. -MART SUPERGENTER Oil CEDAR ST MONTICELLO, MN 55362 STORE 115624 - SHOP DRAWING )RAWN BY BEF SHEET I .-1....,._ I. - - A c 11411 I FP 3 OF