Loading...
2012-00542CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 406 7TH ST E PIN 155029002070 LEGAL DESC LAURING HILLSIDE TERRACE LOT 007 BLOCK 002 PERMIT TYPE BUILDING PROPERTY TYPE COMMERCIAL CONSTRUCTION TYPE : ANTENNA VALUATION : $ 6,500.00 NOTE: ADDITION OF TWO MICROWAVE ANTENAS APPLICANT ONE WAY BUILDING SERVICES 6811 WASHINGTON AVE EDINA, MN 55459- 952)942-0412 Minnesota State License #: 41-1296433 OWNER ALLIED PROPERTY MANAGEMENT ` 20125 COMMERCIAL BLVD. #1000 ROGERS, MN 55374- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb sidewalk, public utilities and signs will be repaired at my expense Applicant Date Bldg Official Date 2 0 1 2— 0 0 5 4 2* DATE ISSUED: 10/02/2012 BUILDING PERMIT FEE 147.61 PLAN REVIEW 95.95 STATE SURCHARGE, BLDG VAL 5.00 TOTAL 248.56 PAID WITH CHECK # 8847 e Row "j e,as rt t_ SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. MONTiCELLO DEVELOPMENT SERVICES BUILDING INSPECTIONS 505 WALNUT STREET. SUITE i IOi`iTICELLO. tt•N 55362 Cite Hall (763) 295-271 1 PID Building Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: 140& ca,54-;Y-"',1r&4ZONED LEGAL: Lot _( ,,., R- Block ,a Plat ,Zara ,t V4A lo pv r ro Property Owner Name: r 1t,E- t hnrtrnn SS-2s Phone: Address: / D b fan- -+k R* v Ctty: f akt roju-_) State:ok) _ Zip; z Contractor Name:Cj0Q_L0i 'mI(NQ Q' r\)l r State License #: 4/-1 910, 3 1 Address: / R / (, Iitr9k"n 0Iw City: a Eng./ Architect Name:1aMW_k, Address: I City: 661i, Plumber Name: Address: City: Mechanical Name: Address: City: Tvve of Work 2/ New Addition Alteration Repair ml ove Other Tvi) e of Construction Single Family Duplex Multi - Family Commercial Industrial Residential Garage Other Description of ivork:A_, hw kL.%30 (o i m C nuz_n_vv . Phone: State: flk) Zip: 59y 5 °i Phone: Stater_ Zip:1R637-- Phone: Phone: State: Zip: State: Zip: BuildintLy Information Use of building of stories Floor area sq. ft. Estimated value of construction S `0( Is this a "i•Iaster Plan" per MN Rule 1300. 0160 Sttbp.6? Yes No FOR ROOF & SIDING PERNTITS, PLEASE PROVIDE # OF SQUARES OF SHINGLES &/OR SIDING. i hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. 1 agree that the work will be conducted in conformance with the ordinances of the City of Monticello and -with the Laws of the State of Minnesota: and that I understand that this application is not a pennit and that the work is not to start %%ithout a permit. 1 further understand that the work will be in accordance with the plan that has been approved by the Building Official. 1 agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE BACK FOR PLUAMING L 9A2A9Dl AND MECHANICAL INFO. Annliennf Stannturr Annliratinn T)ato APPLICANT. Please show ft_ttrn•es that are applicable. Fire S1tnUr•essioit : (if 'applicable) Pluntbina: (if applicable) Mechanical: (if applicable) No. Fixture Tvne So. Fixture Tvne o. Fixture Tvne Sprinkler Ileads Water Closet (toilet) Furnace Other/Special FS Device Bathtub Gas.tleter Larator r (rush basin) Rowe Hood Shon•er Gas Range Kitchen Sink Water Heater Dislnrtrsher iir Conditioning Loundry Tub Mech. Fireplace Fire .4lan t: (if applicable) Clothes Washer Batln•oonr(s) Exhaust Fan Hitter Healer air Exchum erzl t Final Dryer fin. i ixture'Tvne Drinking, Fountain Gas Opening n/o Fixture , Floor Drain of Devices slop Sink Other Ih rh Forts 7 U7:1 L T07:1 L S9 Per Fixture) S9 Per Fixture) FOR CITY USE ONLY Trce Ordinance Handout Yes NO FEES: Other handouts I? Yes No Bldg. Pennit Plan Review State Surchar-e Bldg. Total Phil,. Permit Fixtures ADDITIONAL INFO R.\IATION: Surchame Valuation: 6.. SO D Plmg. Total Construction Type: Mech. Permit Occupancy Croup: Fixtures Division: Surcharge Square Footage: illech. Total r Of Stories: Sewer Access of Residential Units: Water Access Maximum Occupancy: Water Meter Fire Sprinklers: LJ Yes L, \o Meter Sales Tax Off -Street Parkin, Covered: Meter •Total Off -Street Parking Uncovered: Sew S, Water Permit Tnink Water Trunk Sanitary Sewer Bi ldino Official Trunk Stomi Sever BP1': Lift Station TOTAL FEES: T-Mobile Central LLC 8000 W. 78t' Street, Suite 400 Edina, MN 55439 City of Monticello 505 Walnut Street, Suite 1 Monticello, MN 55362 Eligible Facilities Request Submitted: September 7, 2012 Local Government Application #: Site Address: 406 East 7"' Street, City of Monticello, MN Re: Section 6409 Eligible Facility Request to Modify Existing Tower or Base Station T-Mobile Site #A1O0800 Legal description: Lots 6, 7, 8 Block 2, Lauring Hillside Terrace Dear Ron: T-Mobile LLC ("T-Mobile") submits this Eligible Facilities Request to modify an existing wireless tower that does not substantially change the physical dimensions of such tower pursuant to Section 6409 of the Middle Class Tax Relief and Job Creation Act 2012, enacted on February 22, 2012 ( a copy of which is attached hereto). Section 6409 of the Middle Class Tax Relief and Job Creation Act requires the City of Monticello to grant T-Mobile's request to modify an existing wireless tower or base station so long as T-Mobile's proposed modification does not substantially change the physical dimensions of the tower or base station. The legislative history for Section 6409 clearly establishes the intent of Congress. "Section 6409. This section streamlines the process for siting wireless facilities by preempting the ability of State and local authorities to delay collocation, removal of, and replacement of wireless transmission equipment. emphasis added). 158 Cong. Rec E237-39 (daily ed. February 24, 2012) (Statement of Rep. Fred Upton) As set forth in the materials submitted herewith, T-Mobile's modification involves the addition of transmission equipment and does not substantially change the physical dimensions of the tower or base station. Specifically, T-Mobile will be co -locating on the existing Crown Castle 159 foot monopole and adding two (2) two (2) foot microwave antennas. The proposed antennas RAD center will be at 142 feet. Section 6409 of the Tax relief Act of 2012 preempts State and local government regulations pertaining to modifications of existing cell towers and base stations other than the a . lication of the new federal standard -do the modifications substantially change the physical me ionsMe y b se station- and the issuance of generally applicable administrativep uci °o°r° u'rTOPv permits. This jurisdiction is prohibited from requiring T-Mobile to b t nforhri AIN'MaKS Qataneous to the very limited review that this jurisdiction is allowed to cond nct zi'r`d'er thijtQ1'dM919Tq gquAWsPTbibN jurisdiction is also precluded from applying special or conditional use permits, state or local environmental, variance or other use regulations in processing this Eligible Facilities Request. The Tax Relief Act requires this jurisdiction to issue a final determination on this Eligible Facilities Request promptly. Accordingly, T-Mobile requests a written answer to this Eligible Facilities Request within 30 days. Thank you for your consideration of this Eligible Facilities Request and we look forward to working with you to provide better wireless services to your community. Sincerely, Claire Aspess Project Manager Faulk and Foster o/b/o T-Mobile LLC 773-209-2325 Enc: 1. Eligible Facilities Request 2. Legal Description of Property 3. Construction Drawings depicting works do not substantially change the physical dimensions of the tower 4. Structural Analysis 5. Copy of the Middle Class Tax Relief and Job Creation Act 2012 APPROVED FILE COPY REVIEWED FOR CODE COMPLIANCE SUBJECT TO FIELD INSPECTION Date: -26- Signed Date:, August 13, 2012 Branden Woodard Crown Castle 11 Grandview Circle, Suite 220 Canonsburg, PA 15317 Subject: Structural Analysis Report Carrier Designation: T-Mobile Co -Locate Carrier Site Number: Carrier Site Name: V C A'OS TWL E Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 724) 416-2000 A100800A Crown Castle #878532 Crown Castle Designation., Crown Castle BU Number: 878532 Crown Castle Site Name: F1/MONTICELLO/FULFILLMENT SYST Crown Castle JDE Job Number: 198441 Crown Castle Work Order Number: 518410 Crown Castle Application Number: 155789 Rev. 3 Engineering Firm Designation: Crown Castle Project Number: 518410 Site Data: 406 EAST 7TH STREET, MONTICELLO, Wright County, MN Latitude 45° 97'53.22", Longitude-930 47- 32.84" 159 Foot - Monopole Tower Dear Branden Woodard, Crown. Castle is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural Statement of Work' and the terms of Crown Castle Purchase Order Number 518410, in accordance with application 155789, revision 3. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity Note: See Table I and Table II for the proposed and existing/reserved loading, respectively. The analysis has been performed in accordance with the TIAIEIA-222-F standard and local code requirements based upon a wind speed of 80 mph fastest mile. All modifications and equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at Crown Castle appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Structural analysis prepared by: Adam Junstrom, E.I.T. / SLS Respectfully subgided by Aaron C. Poot, Manager Engir tnxTower Report - APPROVED FILE COPY REVIEWED FOR CODE COMPLIANCE pROFESS1OIRAL ENGIi M I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. SUBJECT TO FIELD INSPECTION Print Name: C. P?Vt Signature: SZ. A,g_. signet% ate: 13/I?- license -9_44468 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing and Reserved Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 — Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations August 13, 2012 CC/ BU No 878532 Page 2 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 1) INTRODUCTION August 13, 2012 CC/ BU No 878532 Page 3 This tower is a 159 ft Monopole tower designed by ENGINEERED ENDEAVORS, INC. in April of 2003. The tower was originally designed for a wind speed of 85 mph per TIA/EIA-222-F. The tower has been modified per reinforcement drawings prepared by GPD Associates, Inc, in April of 2008. Reinforcement consists of addition of base plate stiffeners. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA/EIA-222-F Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a fastest mile wind speed of 80 mph with no ice, 37.6 mph with 0.75 inch ice thickness, and 50 mph under service loads. Table 1 - Proposed Antenna and Cable Information Center Number Mounting Line of Antenna Antenna Model Level (ft) Elevation Antennas Manufacturer ft) 1 andrew VHLP2-11 140.0 1 tower mounts Pipe Mount [PM 601-1] 140.0 1 andrew VHLP2-18 139.0 1 tower mounts Pipe Mount [PM 601-1] Table 2 - Existing and Reserved Antenna and Cable Information Number Feed of Feed Line Note Lines Size (in) 2 3/8 - Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Note Level (ft) Elevation Antennas Manufacturer Lines Size ft) in) 1 kmw ET-X-TS-70-15-62-18-iR-RD communications w/ Mount Pipe 2 powerwave P90-15-XLPP-RR technologies w/ Mount Pipe 157.0 3 1-1/4 2 155.0 3 samsung RRH-C2A w/EXT FILTER telecommunications 3 samsung RRH-P4 telecommunications 155.0 1 tower mounts T-Arm Mount [TA 601-3] 1 142.0 9 andrew TMBX-6517-R2M w/ Mount Pipe 140.0 6 andrew ETT19V2S12UB 18 1-5/8 1 140.0 1 tower mounts Platform Mount [LP 303-1] 12 andrew 641280-DF 120.0 123.0 6 powerwave RA21.7770.00 w/ Mount Pipe 12 1-5/8 1 technologies 120.0 1 tower mounts Platform Mount [LP 701-1] Notes: 1) Existing Equipment 2) Reserved Equipment tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Table 3 - Design Antenna and Cable Information Center Number Mounting Line of Antenna Level (ft) Elevation Antennas Manufacturer ft) 160 160 12 dapa 140 140 12 dapa 120 120 12 dapa 100 100 12 dapa 80 80 12 dapa 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document 4-GEOTECHNICAL REPORTS 4-POST-MODIFICATION INSPECTION 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 4-TOWER MANUFACTURER DRAWINGS 4-TOWER REINFORCEMENT DESIGN/DRAWINGS/DATA 3.1) Analysis Method Remarks Terracon GPD Associates, Inc. Engineered Endeavors, Inc. Engineered Endeavors, Inc. GPD Associates, Inc. August 13, 2012 CCI BU No 878532 Page 4 Number Feed Antenna Model of Feed Line Lines Size (in) 48000 48000 48000 48000 48000 Reference 1504987 2286749 1621567 1617475 2231372 Source CCISITES CCISITES CCISITES CCISITES CCISITES tnxTower (version 6.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) When applicable, transmission cables are considered as structural components for calculating wind loads as allowed by TIA/EIA-222-F. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 4) ANALYSIS RESULTS Table_5_- Section Capacity (Summary) Section Elevation (ft) I Component Size No. Type , L1 1 159- 133.42 Pole TP21.29x16x0.1875 L2 133.42- Pole TP30.21x20.26014.2587.837 L3 87.837 Pole TP38.8x28.8256x0.3125 43.2903 L4 43.2903 - 0 Pole TP4707.06970.375 August 13, 2012 CCI BU No 878532 Page 5 Critical P (K) SF•P_allow Pass / Fail Element K) Capacity 1 3.33 632.62 35.2 Pass 2 10.30 1199.42 95.4 Pass 3 17.22 1927.60 101.4 Passe 4 28.24 2885.04 94.1 Pass Table 6 - Tower Component Stresses vs. Capacity — LC7_ Notes Component Elevation (ft) 1 Anchor Rods 0 1 Base Plate 0 1 Base Foundation 0 Summary Pole (1-3) 101.4 PassZ Rating = 101.4 Passe Capacity I Pass / Fail 93.1 Pass 96.8 Pass 78.5 Pass Structure Rating (max from all components) = I 101.4%2 Notes: 1) See additional documentation in "Appendix C — Additional Calculations" for calculations supporting the % capacity consumed. 2) Capacities up to 105% are considered acceptable based on analysis methods used. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing, reserved, and proposed loads. No modifications are required at this time. tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 APPENDIX A TNXTOWER OUTPUT August 13, 2012 CCI BU No 878532 Page 6 tnxTower Report - version 6.0.4.0 N Nr` O N < !! N N N 2 87.8 it 43.3If 0.0IfIf N AXIAL 48 K DESIGNED APPURTENANCE LOADING 1 TYPE ELEVATION TYPE ELEVATION I Lighting Rod 3/4' x 4' 159 1(2) ETTl svzsl2UB 140 1 ET-X-TS-70.15.62.16-IR-RD w/ Mount 155 2) ETi19VZS12UB 140 Pipe I Pipe Mount [PM 601-11 1140 1 P90.15-XLPP-RR w/ Mount Pipe 155 I Pipe Mount [PM 601-11 1140 1 1 RRH-C2A w/EXT FILTER 155 1 Platform Mount [LP 303-11 1140 1 1 RRH-C2A w/EXr FILTER 155 PM 1(3) TMBX-6517-Rw/ Mount Pipe li 140 RRH-C2A w/EXT FILTER 155 1 VHLP2.11 140 1 I RRH- P4 155 1 VHLP2.18 140 1 1 RRH- P4 155 1(4) 641n0-DF 1120 I 1 RRH- P4 155 1(4) 6412MDF 1120 1 1 T- Arm Mount [TA 601-31 155 IN) 641280-DF 1120 1 1(3) Fx2' Antenna Mount Pipe 155 1 Platform Mount tLP 701.11 1120 I 1(3) Irx2' Antenna Mount Pipe 155 1(2) Tx2' Antenna Mount Pipe 1120 1 1(3) 8'x2- Antenna Mount Pipe 155 1(2) Tx2' Antenna Mount Pipe 1120 1 1 P90. 15-XLPP-RR w/ Mount Pipe 155 1(2) Tx2 Antenna Mount Pipe 1120 1 1(3) TMBX-6517-RZM w/ Mount Pipe 140 1(2) RA21.7770.00 w/ Mount Pipe 1120 31 TMBX- 6517-R2M w/ Mount Pipe 140 1(2) RA21.7770.00 w/ Mount Pipe 1120 2) ETT19V2S12UB 140 1(2) RA21.7770.00 w/ Mount Pipe 1120 1 MATERIAL STRENGTH GRADE 1ssk Fy Fu I GRADE I Fy 1 Fu N j 180. Y TOWER DESIGN NOTES 1. Tower is located in Wright County, Minnesota. 2. Tower designed for a 80 mph basic wind in accordance with the TIA/EIA-222-F Standard. 3. Tower is also designed for a 38 mph basic wind with 0.75 in ice. Ice is considered to increase in thickness with height. 4. Deflections are based upon a 50 mph wind. 5. TOWER RATING: 101.4% SHEAR MOMENT 7 K 820 kip-ff 1 TORQUE 0 kip-ft 38 mph WIND - 0.7500 in ICE i AXIAL 28 KK SHE24KA J , MOMENT 24 K 2574 kip-lt TORQUE 0 kip-R REACTIONS - 80 mph WIND Crown Castle 1ob: BU# 878532 CROV 2000 Corporate Drive Pf*11 d/' CAS E calenl: Crown Castle Drawn by: Adam Junstro pd' Canonsburg PA 15317 We Are Solutions Phone: (724) 416-2000 fie' TIA/EIA-222-F Date:08/09/12 fie' NTS FAX: Path: p a vn,- rwr w•mns>s a. vemiv Dxg No. E-1 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Tower Input Data August 13, 2012 CCI BU No 878532 Page 7 There is a pole section. This tower is designed using the TIA/EIA-222-F standard. The following design criteria apply: 3) Tower is located in Wright County, Minnesota. 4) Basic wind speed of 80 mph. 5) Nominal ice thickness of 0.7500 in. 6) Ice thickness is considered to increase with height. 7) Ice density of 56 pcf. 8) A wind speed of 38 mph is used in combination with ice. 9) Temperature drop of 50 OF. 10) Deflections calculated using a wind speed of 50 mph. 11) A non -linear (P-delta) analysis was used. 12) Pressures are calculated at each section. 13) Stress ratio used in pole design is 1.333. 14) Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Options Distribute Leg Loads As Uniform Assume Legs Pinned 4 Assume Rigid Index Plate 4 Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension 4 Bypass Mast Stability Checks 4 Use Azimuth Dish Coefficients 4 Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends 4 Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feedline Bundles As Cylinder Use ASCE 10 X-Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation 4 Consider Feedline Torque Include Angle Block Shear Check Poles Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 159.00-133.42 25.58 3.17 18 16.0000 21.2900 0.1875 0.7500 A572-65 65 ksi) L2 133.42-87.84 48.75 4.33 18 20.2601 30.2100 0.2500 1.0000 A572-65 65 ksi) L3 87.84-43.29 48.88 5.42 18 28.8256 38.8000 0.3125 1.2500 A572-65 65 ksi) L4 43.29-0.00 48.71 18 37.0697 47.0000 0.3750 1.5000 A572-65 65 ksi) Tapered Pole Properties Section Tip Dia. Area 1 r C in in2 in' in in L1 16.2468 9.4104 297.2674 5.6134 8.1280 l/C J It/Q w w/t in' in4 W in 36.5733 594.9259 4.7061 2.4860 13.259 tnxTower Report - version 6.0.4.0 August 13, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 518410, Application 155789, Revision 3 Page 8 Section Tip Dia. Area 1 r C I/C J It/Q w w/t in inz in' in in in' in° in2 in 21.6184 12.5586 706.5573 7.4914 10.8153 65.3293 1414.0443 6.2805 3.4170 18.224 L2 21.2290 15.8780 803.2105 7.1036 10.2921 78.0414 1607.4779 7.9405 3.1258 12.503 30.6760 23.7733 2695.9374 10.6358 15.3467 175.6691 5395.4222 11.8889 4.8770 19.508 L3 30.1681 28.2814 2904.8668 10.1221 14.6434 198.3740 5813.5559 14.1434 4.5233 14.475 39.3986 38.1748 7144.1983 13.6631 19.7104 362.4583 14297.797 19.0910 6.2788 20.092 1 L4 38.7629 43.6758 7429.9282 13.0266 18.8314 394.5501 14869.632 21.8421 5.8643 15.638 8 47.7251 55.4954 15241.656 16.5519 23.8760 638.3673 30503.368 27.7530 7.6120 20.299 7 7 Tower Gusset Gusset Gusset GradeAdjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt per face) Ar Spacing Spacing Diagonals Horizontals ft fe in in in L1 159.00- 1 1 1 133.42 L2 133.42- 1 1 1 87.84 L3 87.84- 1 1 1 43.29 L4 43.29-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Face Allow Component Placement Total Number Clear Width or Perimete Weight or Shield Type Number Per Row Spacing Diamete r Leg ft in r plf in in Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft flz/ft plf TYPE 5(1 1/4") B No CaAa (Out Of 155.00 - 0.00 2 No Ice 0.13 1.10 Face) 1/2" Ice 0.23 2.18 1" Ice 0.33 3.86 2" Ice 0.53 9.07 4" Ice 0.93 26.81 TYPE 5( 1 1/4") B No CaAa (Out Of 155.00 - 0.00 1 No Ice 0.00 1.10 Face) 1/2" Ice 0.00 2.18 1" Ice 0.00 3.86 2" Ice 0.00 9.07 4" Ice 0.00 26.81 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 3 No Ice 0.20 0.70 Face) 1/2" Ice 0.30 2.23 1" Ice 0.40 4.38 2" Ice 0.60 10.50 4" Ice 1.00 30.07 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 15 No Ice 0.00 0.70 Face) 1/2" Ice 0.00 2.23 1" Ice 0.00 4.38 2" Ice 0.00 10.50 4" Ice 0.00 30.07 CNT-400(3/8") C No CaAa (Out Of 140.00 - 0.00 2 No Ice 0.00 0.07 Face) 1/2" Ice 0.00 0.62 1" Ice 0.00 1.78 2" Ice 0.00 5.94 4" Ice 0.00 21.59 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 August 13, 2012 CCI BU No 878532 Page 9 Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg It felft off LDF7-50A(1-5/8") C No Inside Pole 120.00 - 0.00 12 No Ice 0.00 0.82 1/2" Ice 0.00 0.82 1" Ice 0.00 0.82 2" Ice 0.00 0.82 4" Ice 0.00 0.82 Feed Line/Linear Appurtenances Section Areas Tower Tower Face An AF CAAA CAAA Weight Sectio Elevation In Face Out Face n It ft2 ft2 ft2 ft2 K 1-1 159.00-133.42 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 5.438 0.07 C 0.000 0.000 0.000 3.968 0.08 1-2 133.42-87.84 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 11.487 0.15 C 0.000 0.000 0.000 27.487 0.90 1-3 87.84-43.29 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 11.226 0.15 C 0.000 0.000 0.000 26.862 1.01 L4 43.29-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 10.909 0.14 C 0.000 0.000 0.000 26.104 0.98 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice An AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Leg in ft2 ft2 ft2 ft2 K 1-1 159.00-133.42 A 0.896 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 13.175 0.23 C 0.000 0.000 0.000 7.506 0.49 1-2 133.42-87.84 A 0.866 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 27.828 0.48 C 0.000 0.000 0.000 51.999 3.68 1-3 87.84-43.29 A 0.814 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 26.660 0.46 C 0.000 0.000 0.000 50.013 3.62 L4 43.29-0.00 A 0.750 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 25.000 0.42 C 0.000 0.000 0.000 47.241 3.33 Feed Line Center of Pressure Section Elevation CPX CPZ CPX CPZ Ice Ice It in in in in 1-1 159.00-133.42 0.0482 0.2358 0.1624 0.3948 L2 133.42-87.84 0.3254 0.4576 0.3640 0.6941 1-3 87.84-43.29 0.3509 0.4935 0.4118 0.7807 1-4 43.29-0.00 0.3674 0.5168 0.4424 0.8297 Discrete Tower Loads tnxTower Report - version 6.0.4.0 August 13, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 518410, Application 155789, Revision 3 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft It ft, ft2 K ft ft P90-15-XLPP-RR w/ A From Leg 4.00 0.0000 155.00 No Ice 8.64 6.36 0.07 Mount Pipe 0.00 1/2" 9.29 7.54 0.13 2.00 Ice 9.91 8.43 0.21 1" Ice 11.18 10.24 0.38 2" Ice 13.83 14.10 0.88 4" Ice ET-X-TS-70-15-62-18-iR- B From Leg 4.00 0.0000 155.00 No Ice 8.70 6.49 0.07 RD w/ Mount Pipe 0.00 1/2" 9.37 7.69 0.13 2.00 Ice 10.00 8.62 0.21 1" Ice 11.29 10.47 0.39 2" Ice 13.98 14.36 0.88 4" Ice P90-15-XLPP-RR w/ C From Leg 4.00 0.0000 155.00 No Ice 8.64 6.36 0.07 Mount Pipe 0.00 1/2" 9.29 7.54 0.13 2.00 Ice 9.91 8.43 0.21 t 1" Ice 11.18 10.24 0.38 2" Ice 13.83 14.10 0.88 4" Ice RRH-C2A WEXT FILTER A From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-C2A WEXT FILTER B From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-C2A WEXT FILTER C From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-P4 A From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice RRH-P4 B From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice RRH-P4 C From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice T-Arm Mount [TA 601-3] C None 0.0000 155.00 No Ice 10.90 10.90 0.73 1/2" 14.65 14.65 0.93 Ice 18.40 18.40 1.13 1" Ice 25.90 25.90 1.52 2" Ice 40.90 40.90 2.32 4" Ice 3) 8'x2" Antenna Mount A From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.03 Pipe 0.00 1/2" 2.73 2.73 0.04 0.00 Ice 3.40 3.40 0.06 1" Ice 4.40 4.40 0.12 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Description Face Offset Offsets: Azimuth Placement CAAA or Type Horz Adjustmen Front Leg Lateral t Vert ft ft ft, It It 2" Ice 6.50 4" Ice 3) 8'x2" Antenna Mount B From Leg 4.00 0.0000 155.00 No Ice 1.90 Pipe 0.00 1/2" 2.73 0.00 Ice 3.40 1" Ice 4.40 2" Ice 6.50 4" Ice 3) 8'x2" Antenna Mount C From Leg 4.00 0.0000 155.00 No Ice 1.90 Pipe 0.00 1/2" 2.73 0.00 Ice 3.40 1" Ice 4.40 2" Ice 6.50 4" Ice 3) TMBX-6517-R2M w/ A From Leg 4.00 0.0000 140.00 No Ice 6.26 Mount Pipe 0.00 1/2" 6.88 2.00 Ice 7.48 1" Ice 8.67 2" Ice 11.14 4" Ice 3) TMBX-6517-R2M w/ B From Leg 4.00 0.0000 140.00 No Ice 6.26 Mount Pipe 0.00 1/2" . 6.88 2.00 Ice 7.48 1" Ice 8.67 2" Ice 11.14 4" Ice 3) TMBX-6517-R2M w/ C From Leg 4.00 0.0000 140.00 No Ice 6.26 Mount Pipe 0.00 1/2" 6.88 2.00 Ice 7.48 1" Ice 8.67 2" Ice 11.14 4" Ice 2) ETT19V2S12UB A From Leg 4.00 0.0000 140.00 No Ice 0.67 0.00 1/2" 0.78 0.00 Ice 0.90 1" Ice 1.17 2" Ice 1.81 4" Ice 2) ETT19V2S12UB B From Leg 4.00 0.0000 140.00 No Ice 0.67 0.00 1/2" 0.78 0.00 Ice 0.90 1" Ice 1.17 2" Ice 1.81 4" Ice 2) ETT19V2S12UB C From Leg 4.00 0.0000 140.00 No Ice 0.67 0.00 1/2" 0.78 0.00 Ice 0.90 1" Ice 1.17 2" Ice 1.81 4" Ice Pipe Mount [PM 601-1] A From Leg 4.00 0.0000 140.00 No Ice 3.00 0.00 1/2" 3.74 0.00 Ice 4.48 1" Ice 5.96 2" Ice 8.92 4" Ice Pipe Mount [PM 601-1] B From Leg 4.00 0.0000 140.00 No Ice 3.00 0.00 1/2" 3.74 1.00 Ice 4.48 1" Ice 5.96 2" Ice 8.92 4" Ice Platform Mount [LP 303-11 C None 0.0000 140.00 No Ice 14.66 1/2" 18.87 tnxTower Report - version 6.0.4.0 August 13, 2012 CCI BU No 878532 Page 11 CAAA Weight Side fie K 6.50 0.30 1.90 0.03 2.73 0.04 3.40 0.06 4.40 0.12 6.50 0.30 1.90 0.03 2.73 0.04 3.40 0.06 4.40 0.12 6.50 0.30 5.68 0.04 7.00 0.09 8.15 0.15 10.16 0.30 14.39 0.75 5.68 0.04 7.00 0.09 8.15 0.15 10.16 0.30 14.39 0.75 5.68 0.04 7.00 0.09 8.15 0.15 10.16 0.30 14.39 0.75 0.32 0.01 0.41 0.02 0.50 0.02 0.72 0.04 1.27 0.10 0.32 0.01 0.41 0.02 0.50 0.02 0.72 0.04 1.27 0.10 0.32 0.01 0.41 0.02 0.50 0.02 0.72 0.04 1.27 0.10 0.90 0.07 1.12 0.08 1.34 0.09 1.78 0.12 2.66 0.18 0.90 0.07 1.12 0.08 1.34 0.09 1.78 0.12 2.66 0.18 14.66 1.25 18.87 1.48 August 13, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 518410, Application 155789, Revision 3 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 fe K ft ft Ice 23.08 23.08 1.71 1" Ice 31.50 31.50 2.18 2" Ice 48.34 48.34 3.10 4" Ice 2) RA21.7770.00 w/ A From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ B From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ C From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 4) 641280-DF A From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 3.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF B From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 3.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF C From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 3.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice Platform Mount [LP 701-1] C None 0.0000 120.00 No Ice 59.15 59.15 2.75 1/2" 71.12 71.12 3.42 Ice 83.09 83.09 4.10 1" Ice 107.03 107.03 5.45 2" Ice 154.91 154.91 8.15 4" Ice 2) Tx2" Antenna Mount A From Leg 4.00 0.0000 120.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 2.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) 7'x2" Antenna Mount B From Leg 4.00 0.0000 120.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 2.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) Tx2" Antenna Mount C From Leg 4.00 0.0000 120.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 2.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Description Lighting Rod 3/4" x 4' Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft, ft2 ft ° It August 13, 2012 CCI BU No 878532 Page 13 Weight U C From Leg 0.00 0.0000 159.00 No Ice 0.30 0.30 0.03 0.00 1/2" 0.71 0.71 0.03 2.00 Ice 1.00 1.00 0.04 1" Ice 1.52 1.52 0.06 2" Ice 2.72 2.72 0.14 4" Ice Dishes Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Width Vert ft ft It ft, K VHLP2-11 A Paraboloid w/o From 4.00 0.0000 140.00 2.17 No Ice 3.72 0.03 Radome Leg 0.00 1/2" Ice 4.01 0.05 0.00 1" Ice 4.30 0.07 2" Ice 4.88 0.11 4" Ice 6.04 0.19 VHLP2-18 B Paraboloid w/o From 4.00 0.0000 140.00 2.17 No Ice 3.72 0.03 Radome Leg 0.00 1/2" Ice 4.01 0.05 1.00 1" Ice 4.30 0.07 2" Ice 4.88 0.11 4" Ice 6.04 0.20 Comb. No. 1 Dead Only 2 Dead+Wind 0 deg - No Ice 3 Dead+Wind 30 deg - No Ice 4 Dead+Wind 60 deg - No Ice 5 Dead+Wind 90 deg - No Ice 6 Dead+Wind 120 deg - No Ice 7 Dead+Wind 150 deg - No Ice 8 Dead+Wind 180 deg - No Ice 9 Dead+Wind 210 deg - No Ice 10 Dead+Wind 240 deg - No Ice 11 Dead+Wind 270 deg - No Ice 12 Dead+Wind 300 deg - No Ice 13 Dead+Wind 330 deg - No Ice 14 Dead+Ice+Temp 15 Dead+Wind 0 deg+Ice+Temp 16 Dead+Wind 30 deg+Ice+Temp 17 Dead+Wind 60 deg+Ice+Temp 18 Dead+Wind 90 deg+Ice+Temp 19 Dead+Wind 120 deg+Ice+Temp 20 Dead+Wind 150 deg+Ice+Temp 21 Dead+Wind 180 deg+Ice+Temp 22 Dead+Wind 210 deg+Ice+Temp 23 Dead+Wind 240 deg+Ice+Temp 24 Dead+Wind 270 deg+Ice+Temp Load Combinations Description tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 August 13, 2012 CCI BU No 878532 Page 14 Comb. Description No. 25 Dead+Wind 300 deg+Ice+Temp 26 Dead+Wind 330 deg+Ice+Temp 27 Dead+Wind 0 deg - Service 28 Dead+Wind 30 deg - Service 29 Dead+Wind 60 deg - Service 30 Dead+Wind 90 deg - Service 31 Dead+Wind 120 deg - Service 32 Dead+Wind 150 deg - Service 33 Dead+Wind 180 deg - Service 34 Dead+Wind 210 deg - Service 35 Dead+Wind 240 deg - Service 36 Dead+Wind 270 deg - Service 37 Dead+Wind 300 deg - Service 38 Dead+Wind 330 deq - Service Maximum Member Forces Sectio Elevation Component Condition Gov. Force Major Axis Minor Axis n It Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 159 - 133.42 Pole Max Tension 33 0.00 0.00 0.00 Max. Compression 14 8.14 0.42 0.06 Max. Mx 5 3.37 91.59 0.06 Max. My 2 3.33 0.32 92.09 Max. Vy 11 8.08 91.05 0.55 Max. Vx 8 8.21 0.46 91.89 Max. Torque 8 0.59 L2 133.42 - Pole Max Tension 1 0.00 0.00 0.00 87.837 Max. Compression 14 21.73 2.30 2.07 Max. Mx 11 10.33 669.60 7.90 Max. My 8 10.30 3.09 676.19 Max. Vy 11 16.62 669.60 7.90 Max. Vx 8 16.75 3.09 676.19 Max. Torque 8 0.59 L3 87.837 - Pole Max Tension 1 0.00 0.00 0.00 43.2903 Max. Compression 14 32.54 5.82 4.79 Max. Mx 11 17.23 1474.53 14.94 Max. My 8 17.22 5.49 1486.78 Max. Vy 11 20.32 1474.53 14.94 Max. Vx 8 20.45 5.49 1486.78 Max. Torque 8 0.48 L4 43.2903 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 14 47.84 10.17 8.16 Max. Mx 11 28.24 2553.16 22.44 Max. My 8 28.24 7.93 2571.56 Max. Vy 11 23.89 2553.16 22.44 Max. Vx 8 24.02 7.93 2571.56 Max. Torque 5 0.45 Location Condition Pole Max. Vert Max. Hz Max. H. Max. M, Max. M. Max. Torsion Min. Vert tnxTower Report - version 6.0.4.0 Maximum Reactions Gov. Vertical Horizontal, X Horizontal, Z Load K K K Comb. 21 47.84 0.02 7.20 11 28.26 23.87 0.16 2 28.26 0.24 23.98 2 2566.70 0.24 23.98 5 2540.26 23.79 0.04 9 0.42 11.79 20.75 1 28.26 0.00 0.00 - 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Location Condition Gov. Vertical Horizontal, X Horizontal, Z Load K K K Comb. Min. H. 5 28.26 23.79 0.04 Min. H. 8 28.26 0.06 23.99 Min. Mx 8 2571.56 0.06 23.99 Min. Mz 11 2553.16 23.87 0.16 Min. Torsion 5 0.45 23.79 0.04 August 13, 2012 CCI BU No 878532 Page 15 Tower Mast Reaction Summary I Load Vertical Shear Shear= Overturning Overturning Torque Combination Moment, Mx Moment, M. K K K kip-ft kip-ft kip-ft Dead Only 28.26 0.00 0.00 1.36 1.18 0.00 Dead+Wind 0 deg - No Ice 28.26 0.24 23.98 2566.70 36.17 0.01 Dead+Wind 30 deg - No Ice 28.26 11.86 20.63 2203.23 1264.21 0.07 Dead+Wind 60 deg - No Ice 28.26 20.59 11.89 1268.57 2197.92 0.30 Dead+Wind 90 deg - No Ice 28.26 23.79 0.04 7.60 2540.26 0.45 Dead+Wind 120 deg - No Ice 28.26 20.64 12.20 1315.98 2204.75 0.28 Dead+Wind 150 deg - No Ice 28.26 11.90 20.86 2238.91 1270.37 0.05 Dead+Wind 180 deg - No Ice 28.26 0.06 23.99 2571.56 7.93 0.24 Dead+Wind 210 deg - No Ice 28.26 11.79 20.75 2224.11 1256.49 0.42 Dead+Wind 240 deg - No Ice 28.26 20.70 11.95 1280.86 2216.25 0.30 Dead+Wind 270 deg - No Ice 28.26 23.87 0.16 22.44 2553.16 0.09 Dead+Wind 300 deg - No Ice 28.26 20.74 12.05 1291.52 2221.81 0.06 Dead+Wind 330 deg - No Ice 28.26 12.11 20.74 2218.80 1302.55 0.04 Dead+Ice+Temp 47.84 0.00 0.00 8.16 10.17 0.00 Dead+Wind 0 47.84 0.06 7.20 802.32 19.80 0.01 deg+Ice+Temp Dead+Wind 30 47.84 3.56 6.20 688.40 389.56 0.06 deg+Ice+Temp Dead+Wind 60 47.84 6.18 3.57 393.02 684.51 0.16 deg+Ice+Temp Dead+Wind 90 47.84 7.15 0.01 10.19 792.75 0.22 deg+Ice+Temp Dead+Wind 120 47.84 6.20 3.65 421.82 686.71 0.17 deg+Ice+Temp Dead+Wind 150 47.84 3.58 6.26 713.86 391.83 0.07 deg+Ice+Temp Dead+Wind 180 47.84 0.02 7.20 819.23 7.43 0.05 deg+Ice+Temp Dead+Wind 210 47.84 3.54 6.23 709.55 407.29 0.15 deg+Ice+Temp Dead+Wind 240 47.84 6.21 3.59 411.90 709.14 0.16 deg+Ice+Temp Dead+Wind 270 47.84 7.16 0.04 1.53 815.93 0.13 deg+Ice+Temp Dead+Wind 300 47.84 6.22 3.62 399.73 710.99 0.11 deg+Ice+Temp Dead+Wind 330 47.84 3.63 6.23 692.92 420.11 0.07 deg+Ice+Temp Dead+Wind 0 deg - Service 28.26 0.09 9.37 1004.10 14.90 0.01 Dead+Wind 30 deg - Service 28.26 4.63 8.06 861.75 494.22 0.03 Dead+Wind 60 deg - Service 28.26 8.04 4.64 495.80 859.78 0.12 Dead+Wind 90 deg - Service 28.26 9.29 0.02 3.84 993.81 0.18 Dead+Wind 120 deg - 28.26 8.06 4.76 516.13 862.51 0.11 Service Dead+Wind 150 deg - 28.26 4.65 8.15 877.50 496.67 0.02 Service Dead+Wind 180 deg - 28.26 0.02 9.37 1007.73 2.37 0.10 Service Dead+Wind 210 deg - 28.26 4.61 8.11 871.67 492.68 0.17 Service Dead+Wind 240 deg - 28.26 8.09 4.67 502.36 868.47 0.12 . Service Dead+Wind 270 deg - 28.26 9.32 0.06 7.93 1000.36 0.03 Service tnxTower Report - version 6.0.4.0 August 13, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 518410, Application 155789, Revision 3 Page 16 Load Vertical Shear,, Shear, Overturning Overturning Torque Combination Moment, M Moment, M. K K K kip-ft kip-ft kip -It Dead+Wind 300 deg - 28.26 8.10 4.71 504.83 870.67 0.02 Service Dead+Wind 330 deg - 28.26 4.73 8.10 867.90 510.75 0.02 Service Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ Error Comb. K K K K K K 1 0.00 28.26 0.00 0.00 28.26 0.00 0.000% 2 0.24 28.26 23.98 0.24 28.26 23.98 0.000% 3 11.86 28.26 20.63 11.86 28.26 20.63 0.000% 4 20.59 28.26 11.89 20.59 28.26 11.89 0.000% 5 23.79 28.26 0.04 23.79 28.26 0.04 0.000% 6 20.64 28.26 12.20 20.64 28.26 12.20 0.000% 7 11.90 28.26 20.86 11.90 28.26 20.86 0.000% 8 0.06 28.26 23.99 0.06 28.26 23.99 0.000% 9 11.79 28.26 20.75 11.79 28.26 20.75 0.000% 10 20.70 28.26 11.95 20.70 28.26 11.95 0.000% 11 23.87 28.26 0.16 23.87 28.26 0.16 0.000% 12 20.74 28.26 12.05 20.74 28.26 12.05 0.000% 13 12.11 28.26 20.74 12.11 28.26 20.74 0.000% 14 0.00 47.84 0.00 0.00 47.84 0.00 0.0000/0 15 0.06 47.84 7.20 0.06 47.84 7.20 0.000% 16 3.56 47.84 6.20 3.56 47.84 6.20 0.000% 17 6.18 47.84 3.57 6.18 47.84 3.57 0.000% 18 7.15 47.84 0.01 7.15 47.84 0.01 0.000% 19 6.20 47.84 3.65 6.20 47.84 3.65 0.000% 20 3.58 47.84 6.26 3.58 47.84 6.26 0.000% 21 0.02 47.84 7.20 0.02 47.84 7.20 0.000% 22 3.54 47.84 6.23 3.54 47.84 6.23 0.000% 23 6.21 47.84 3.59 6.21 47.84 3.59 0.000% 24 7.16 47.84 0.04 7.16 47.84 0.04 0.000% 25 6.22 47.84 3.62 6.22 47.84 3.62 0.000% 26 3.63 47.84 6.23 3.63 47.84 6.23 0.000% 27 0.09 28.26 9.37 0.09 28.26 9.37 0.000% 28 4.63 28.26 8.06 4.63 28.26 8.06 0.000% 29 8.04 28.26 4.64 8.04 28.26 4.64 0.000% 30 9.29 28.26 0.02 9.29 28.26 0.02 0.000% 31 8.06 28.26 4.76 8.06 28.26 4.76 0.000% 32 4.65 28.26 8.15 4.65 28.26 8.15 0.000% 33 0.02 28.26 9.37 0.02 28.26 9.37 0.000% 34 4.61 28.26 8.11 4.61 28.26 8.11 0.000% 35 8.09 28.26 4.67 8.09 28.26 4.67 0.000% 36 9.32 28.26 0.06 9.32 28.26 0.06 0.000% 37 8.10 28.26 4.71 8.10 28.26 4.71 0.000% 38 4.73 28.26 8.10 4.73 28.26 8.10 0.000% Non -Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00010434 3 Yes 6 0.00000001 0.00015204 4 Yes 6 0.00000001 0.00015099 5 Yes 5 0.00000001 0.00004096 6 Yes 6 0.00000001 0.00015328 7 Yes 6 0.00000001 0.00015498 8 Yes 5 0.00000001 0.00009997 9 Yes 6 0.00000001 0.00014974 tnxTower Report - version 6.0.4.0 August 13, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 518410, Application 155789, Revision 3 Page 17 10 Yes 6 0.00000001 0.00015332 11 Yes 5 0.00000001 0.00012419 12 Yes 6 0.00000001 0.00015523 13 Yes 6 0.00000001 0.00015229 14 Yes 4 0.00000001 0.00006700 15 Yes 5 0.00000001 0.00047139 16 Yes 6 0.00000001 0.00012233 17 Yes 6 0.00000001 0.00012134 18 Yes 5 0.00000001 0.00046518 19 Yes 6 0.00000001 0.00013134 20 Yes 6 0.00000001 0.00012927 21 Yes 5 0.00000001 0.00047896 22 Yes 6 0.00000001 0.00012960 23 Yes 6 0.00000001 0.00013330 24 Yes 5 0.00000001 0.00047567 25 Yes 6 0.00000001 0.00013054 26 Yes 6 0.00000001 0.00013111 27 Yes 4 0.00000001 0.00033061 28 Yes 5 0.00000001 0.00040252 29 Yes 5 0.00000001 0.00039832 30 Yes 4 0.00000001 0.00033109 31 Yes 5 0.00000001 0.00042109 32 Yes 5 0.00000001 0.00042274 33 Yes 4 0.00000001 0.00048996 34 Yes 5 0.00000001 0.00039516 35 Yes 5 0.00000001 0.00041425 36 Yes 4 0.00000001 0.00044641 37 Yes 5 0.00000001 0.00042511 38 Yes 5 0.00000001 0.00041517 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. L1 159-133.42 58.066 32 3.2257 0.0027 L2 136.587 - 87.837 43.160 32 3.0692 0.0024 L3 92.1703 - 18.706 32 2.0365 0.0005 43.2903 L4 48.707 - 0 4.942 32 0.9476 0.0002 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in oft 159.00 Lighting Rod 3/4" x 4' 32 58.066 3.2257 0.0035 16783 155.00 P90-15-XLPP-RR w/ Mount Pipe 32 55.359 3.2087 0.0035 16783 140.00 VHLP2-11 32 45.366 3.1082 0.0032 4419 139.00 VHLP2-18 32 44.716 3.0976 0.0032 4209 120.00 2) RA21.7770.00 w/ Mount Pipe 32 33.015 2.7691 0.0023 2885 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load It in Comb. L1 159 - 133.42 147.522 8 8.2110 0.0068 L2 136.587 - 87.837 109.734 7 7.8143 0.0059 L3 92.1703 - 47.660 7 5.1906 0.0011 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. 43.2903 L4 48.707 - 0 12.608 7 2.4176 0.0005 August 13, 2012 CCI BU No 878532 Page 18 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature It Comb. in It 159.00 Lighting Rod 3/4" x 4' 8 147.522 8.2110 - 0.0089 6846 155.00 P90-15-XLPP-RR w/ Mount Pipe 8 140.659 8.1682 0.0087 6846 140.00 VHLP2-11 7 115.323 7.9133 0.0079 1799 139.00 VHLP2-18 7 113.677 7.8864 0.0078 1714 120.00 2) RA21.7770.00 w/ Mount Pipe 7 84.004 7.0524 0.0056 1166 Compression Checks Pole Design Data Section Elevation Size L L KUr Fa A Actual Allow. Ratio No. P P. P It ft It ksi 0 K K pe L1 159 - 133.42 TP21.29xl6x0.1875 25.58 0.00 0.0 39.000 12.1689 -3.33 474.58 0.007 1) L2 133.42 - TP30.21x20.2601x0.25 48.75 0.00 0.0 39.000 23.0715 -10.30 899.79 0.011 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 48.88 0.00 0.0 39.000 37.0784 -17.22 1446.06 0.012 43.2903(3) HI-3+VT (1.35 CR) - 3 L4 43.2903 - 0 (4) TP47x37.0697x0.375 48.71 0.00 0.0 39.000 55.4954 -28.24 2164.32 0.013 Pole Bending Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. Mx fax FbX fbx My fby Fby fby ft kip-ft ksi ksi Fb, kip-ft ksi ksi Fbe L1 159 - 133.42 TP21.29x16x0.1875 92.09 18.022 39.000 0.462 0.00 0.000 39.000 0.000 1) L2 133.42- TP30.2lx20.260lx0.25 677.28 49.135 39.000 1.260 0.00 0.000 39.000 0.000 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 1488.6 52.255 39.000 1.340 0.00 0.000 39.000 0.000 43.2903(3) 5 L4 43.2903-0 TP47x37.0697x0.375 2574.2 48.390 39.000 1.241 0.00 0.000 39.000 0.000 4) 1 Pole Shear Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. V f, F f T fV, Fv, fV, ft K ksi ksi Fv kip-ft ksi ksi F, L1 159 - 133.42 TP21.29x16x0.1875 8.19 0.673 26.000 0.052 0.35 0.034 26.000 0.001 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 APPENDIX B BASE LEVEL DRAWING August 13, 2012 CCI BU No 878532 Page 20 tnxTower Report - version 6.0.4.0 r 159 Ft Monopole Tower Structural Analysis Project Number 518410, Application 155789, Revision 3 APPENDIX C ADDITIONAL CALCULATIONS August 13, 2012 CCI BU No 878532 Page 21 tnxTower Report - version 6.0.4.0 Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces BUM 878532 TIA Revision: F Site Name: F1/MONTICELLO/FULFILLMENT "I Max. Service Shaft M: 2781.169 ft-kips (* Note) App #: 155789, Rev. 3 Max. Service Shaft P: 28 kips Max Axial Force Type: Comp. Note: Max Shaft Superimposed Moment does not necessarily Enter Load Factors Below: equal to the shaft top reaction moment For M WL 1.:3 <---- Enter Factor For P (DL)) 1 1.3 ' <- Enter Factor Pier Properties Concrete: Pier Diameter =1 6.5 Ift Concrete Area = 4778.4 in Reinforcement. Clear Cover to Tie=l 4.00 in Horiz. Tie Bar Size= 5 I Vert. Cage Diameter = 5.61 ft Vert. Cage Diameter = 67.34 in Vertical Bar Size 11 Bar Diameter = 1.41 in Bar Area = 1.56 in Number of Bars 20 As Total= 31.2 in A s/ Aconc, Rho: 0.0065 0.65% ACI 10.5 , ACI 21.10.4, and IBC 1810. Min As for Flexural. Tension Controlled, Shafts: 3)*(Sq rt(f c)/Fy: 0.0032 200 / Fy: 0.0033 Minimum Rho Check: Actual Req'd Min. Rho:j 0.33% IFlexural Provided Rho: 0.65% JOK Ref. Shaft Max Axial Capacities. cb Max(Pn or Tn): Max Pu = ((p=0.65) Pn. Pn per ACI 318 (10-2) 9366.42 (kips at Mu=((=0.65)Mn= 5264.58 ft-kips MaxTu,((p=0.9)Tn=l 1684.8 Ikips at Mu=(=(0.90)Mn= 0.00 Ift-kips Load Factor Shaft Factored Loads 1.30 Mu: 3615.52 ft-kips 1.30 Pu: 36.4 1 kips Material Properties Concrete Comp. strength, fc = 4000 psi Reinforcement yield strength, Fy = 60 ksi Reinforcing Modulus of Elasticity, E = 29000 ksi Reinforcement yield strain = 0.00207 Limiting compressive strain = 0.003 ACI 318 Code Select Analysis ACI Code= 1 2002 Seismic Properties Seismic Design Category B Seismic Risk = Low Solve I Press Upon Completing All Input Run) Results: Governing Orientation Case: 2 Mu I ` Mu 1,0 Case 1 Case 2 Dist. From Edge to Neutral Axis: 11.92 in Extreme Steel Strain, et: 0.0152 ct > 0.0050, Tension Controlled Reduction Factor,cp: 0.900 Output Note: Negative Pu=Tension For Axial Compression, cp Pn = Pu: 36.40 kips Drilled Shaft Moment Capacity, cpMn: 4604.26 ft-kips Drilled Shaft Superimposed Mu: 3615.52 ft-kips I (Mu/TMn, Drilled Shaft Flexure CSR: I 78.5% Drilled -Shaft -Moment -Capacity, DSMC, Version 1.1 - Effective 04/01/ 2010 Analysis Date: 8/13/2012 Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material I TIA Rev 171 Site Data Reactions BU#:878532 Moment:1 2574 Ift-kips Site Name: F1/MONTICELLO/FULFILL Axial:1 28 kips App #: 155789, Rev. 3 Shear l 24 kips Pole Manufacturer:1 Other Anchor Rod Data If No stiffeners, Criteria: I AISC AS Only Applcable to Unstiffened Cases Qty: 12 Diam: 2.25 in Rod Material: A615-J Anchor Rod Results Stiffened Strength (Fu): 100 ksi Maximum Rod Tension: 181.5 Kips Service, ASD Yield (Fy): 75 ksi Allowable Tension: 195.0 Kips Fty*ASIF Bolt Circle: 56 in Anchor Rod Stress Ratio: 93.1 % Pass Plate Data Diam:1 62 in Base Plate Results Flexural Check Stiffened Thick: 1.75 in Base Plate Stress: 58.0 ksi Service, ASD Grade: 60 ksi Allowable Plate Stress: 60.0 ksi 0.75*Fy*ASIF Single -Rod B-eff: 12.43 in Base Plate Stress Ratio: 96.8% Pass Y.L. Length: N/A, Roark Stiffener Data (Welding at both sides) Config:3 Stiffener Results Weld Type: Both Horizontal Weld: 37.9% Pass Groove Depth: 0.5 in ** Vertical Weld: 38.7% Pass Groove Angler 45 degrees Plate Flex+Shear, fb/Fb+(fv/Fv)^2: 8.3% Pass Fillet H. Weld: 0.1875 in Plate Tension+Shear, ft/Ft+(fv/Fv)^2: 38.1 % Pass Fillet V. Weld: 0.3125 in Plate Comp. (AISC Bracket): 37.7% Pass Width: 6 in Height: 18 in Pole Results Thick: 1 in Pole Punching Shear Check: 8.9% Pass Notch: 1 in Grade: 50 ksi Weld str.: 70 ksi Clear Space between 6 in Stiffeners (b): Pole Data Diam:1 47 in Thick: 1 0.375 in Grader 65 ksi of Sides: 18 0" IF Round Ful 80 ksi Reinf. Fillet Weld 0 0" if None Stress Increase Factor ASIF:) 1.333 1 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5 - Circular Base F 1.2, Effective March 19, 2012 Analysis Date: 8/13/2012 Monopole Drilled Pier Checks capacity of a single drilled shaft foundation for a monopole BU#: 878532 Site Name: F1/MONTICELLO/FULFILLMENT SY App Number: 155789, Rev. 3 Design Reactions Shear, S: 24.00 kips Moment, Mt: 2574.00 ft-kips Tower Weight, Wt: 28.00 kips Tower Height, H: 159 ft Base Diameter, BD: 47.0 in Foundation Dimensions Caisson Diameter, CD: 6.5 ft Fit. Above Grade, E: 1.0 it Depth Below Grade, L: 28.0 it Neglected Depth, N: 5.0 ft Reber Size, Sp: 11 Reber Quantity, mp: 20 Tie Size, tp: 5 IMaterial Properties RebarTensile, Fy: 60 ksi Concrete Strength, F'c: 4000 psi Concrete Density, dx: 150 pd Clear Cover, cc: 4 in ISoil Properties I Soil Unit Weight, y: 105 Allowable Bearing,Bc: 13.500 Ipsfdk Seismic Design Cat, z: B Caisson Analysis Depth to Zero Shear. 8.4 ft Max Factored Moment: 3615.52 ft-kips I Overturning FOS: 4.17 0 CCA TL E ACI 318 Version:l 2002 Design Checks Capacity/ Demand/ Availability Limits Check Minimum RegdDia. 1(M. 6.50 1.63 OK Minimum Req'd Dia. 2 (11): 6.50 5.42 OK Bearing (kso: 13.50 0.84 OK Reber Area (in 2): 31.20 0.00 OK Pier moment capacity (k-ft): 4604.26 3615.52 OK Reber spacing (in): 9.59 2 < Bs <18 OK Development Length (in): 231.79 12.00 OK Soil moment capacity (FOS): 4.17 2.00 OK Depth I IShear I IMoment I I 2.9Ift I 24.11kips I 2649.6ift-kips I 5.8 ft 24.1 kips 2719.E ft-kips I 8.7 ft -3.3 kips 2755.1 ft-kips r Assume 0.33% Minimum Steel? Bearing: 6.3% Steel: 78.5% Soil: 48.0% Monopole Drilled Pier (Caisson) Version 1.5 Effective Date: 04/26/2012 878532_Caisson.txt CAISSON version 10.40 3:21:54 PM Thursday, August 09, 2012 Crown Castle USA k*WR*****##R#444*R4*4**W*A4f 4444f#f4fR#R44*#4*W*A**A**#MA#4#4#44*R*R******f WA4AA44*#R4*4**k*W¢A4¢4 4 W CAISSON - Pier Foundations Analysis and Design - Copyright Power Line Systems, Inc. 1993-2010 ° p A 4*4**¢AAA**4f 4*4#*AAA*****A*A¢4A¢4#444#444#fR*4fR****#AAR¢A#ff444444#*d4#*#****A#*A#4A#4**k*****#R Project Title: BU# 878532 Project Notes: Calculation method: Full BCD I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength ft) (ft) (ksi) (ksi) 6.50 1.00 4.00 60.00 Soil Properties Layer Type Thickness ft) 1 Clay 5.00 2 Sand 23.00 Depth at Top Density of Layer ft) (lbs/ftA3) 0.00 105.0 5.00 105.0 Design (Factored) Loads at Top of Pier moment Axial Shear Additional Safety Load Load Factor Against Soil Failure ft-k) kips) kips) 2574.0 28.0 24.00 4.17 R*##4*k R E S U L T S Calculated Pier Properties Length weight End Bearing Pressure ft) kips) psf) 29.000 144.346 843.8 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density to Top of Pier ft) ft) lbs/ftA3) Clay 1.00 5.00 105.0 Sand 6.00 15.48 105.0 Sand 21.48 7.52 105.0 Shear and moments Along Pier Distance below Shear Top of Pier with Safety Factor ft) kips 0.00 100.5 2.90 100.5 5.80 100.5 8.70 13.7 11.60 190.6 14.50 423.5 20.30 1057.4 23.20 970.2 26.10 513.1 29.00 0.0 CU KP PHI psf) r ( deg) 3.255 32.00 CU KP Force Arm psf) (kips) (ft) 0.00 3.50 3.255 1314.88 15.31 3.255-1214.34 25.44 Moment Shear with Safety Factor) (without Safety Factor) kips) 10757.4 24.1 11049.0 24.1 11340.6 24.1 11488.8 -3.3 11206.1 -45.7 10329.3 -101.6 8695.8 -170.8 6143.2 -253.6 2922.0 -232.7 757.6 -123.1 0.0 -0.0 Page 1 moment without Safety Factor) ft-k) 2579.7 2649.6 2719.6 2755.1 2687.3 2477.1 2085.3 1473.2 700.7 181.7 0.0 Site Doseription Site located at 406 East Seventh Street situated in the City of Monticello, County of Wright, State of Minnesota commonly described as follows= Legal Description: Lots 6, 7, and 8, Block 2, Lauring Hillside Terrace;,according to thb plat thereof on file and of record in the office of the Wright County Recorder. Site Plan: _