Loading...
2012-00549MflflMMMflHMN CITY OF MONTICELLO * 2 0 1 2- 0 0 5 4 9* 505 WALNUT STREET DATE ISSUED: 09/27/2012 MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 406 7TH ST E PIN 155029002070 LEGAL DESC LAURING HILLSIDE TERRACE LOT 007 BLOCK 002 PERMIT TYPE BUILDING PROPERTY TYPE COMMERCIAL CONSTRUCTION TYPE ANTENNA VALUATION $ 18,000.00 NOTE: GLOBAL SIGNAL ACQUISTIONS 1 I I LLC = INSTALL 2 NEW CABINETS ON EXISTING TOWER APPLICANT ALLIED PROPERTY MANAGEMENT 20125 COMMERCIAL BLVD. #1000 ROGERS, MN 55374- OWNER ALLIED PROPERTY MANAGEMENT 20125 COMMERCIAL BLVD. #1000 ROGERS, MN 55374- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb sidewalk, public utilities and signs will be repaired at my expense Applicant Date Bldg Official Date BUILDING PERMIT FEE 310.85 PLAN REVIEW 202.05 STATE SURCHARGE, BLDG VAL 9.00 TOTAL 521.90 PAID WITH CC # 3026 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. NIONTICELLO DEVELOPMENT SERVICES PERMIT# 7,—aCJ,-Ic BUILDING INSPECTIONS r. m 505 WALNUT STREET, SUITE 1 MONTICELLO, MN 55362 City Ball (763).295-2711 Building.Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING - PERMIT APPLXC ' TION Please Print - INCOMPLETE APPLICATIONS NVILL NOT BE ACCEPTED. SITE ADDRESS: 406 East 7th Str, Monticello, MN 55362 LEGAL: Lot 6, 7, & 8 Block 2 .Plat ZONED Property Owner Name: Global Siqnal Acquisitions III LLC Phone: 724-416-2096 Address: 11 Grandview Circle, Ste 220 City: Canonsburg State: PA Zip: 'J530_ Contractor Name: T.B.D. Phone: State License t Address: City: State: Zip: Eng./Architect Name: Devin Vanmaele Phone: 913-438-7700 Address: City: State: Zip: Plumber Name: n/a Phone: Address: City: State.: Zip: Mechanical.Name: n/a Phone: Address: City: State: Zip: Tvne of Work New Addition Alteration Repair Move Other Tvne of Construction Single Family Duplex Multi -Family Commercial Industrial Residential Garage Other Tower Building Information Use of building Telecommunication Tower of stories Floor area sq. ft. Estimated value of construction S 18,000.00 Is this a "Alaster Plan" per MN Rule 1300.0160 Subp.6? Yes V .No Description of work: 4—le- s 641 7bL" e r _ .FOR ROOF & SIDING PERMITS, 2 new cabinets (1 MMI3S radio cabinet and one battery backupdabinet with rectifier) will be placed within the existing Sprint PLEASE PROVIDE # OF SQUARES leasearea. Also adding 3 antennas, 3 coaxes, and 6 RRU's. This alteration is for Sprint Network Vision equipment, it will replace- Beei, K... cy-._._ 4milifemaln- the and will OF SHINGLES &!OR SIDING. be removed, leaving only the updated Network Vision equipment I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. i agree that the work will be cond, ;Jc t': he City of Monticello and with the Laws of the State of Minnesota; and that I understand that this ap , r t lu at •r r mot to start without a permit. i further understand that the work will be in accordance with the pl -.-las been approved by the gui a t `iicial. I agree that any damage caused to public property including but not limited to curb, sidewalk utilities and signs will be rep .-a my expense. St: r 1 i ZUl1 ODSEE BACKFORPLUMBINGCzLd_' u Applicant Signature/ i /, _ Date iIQalpr, WJ/Sa>lraiu /J 7M AND MECHANICAL INFO. APPLICANT. • Please show fcrtures that are applicable. Fire Suuvression : (if applicable) Plumbine. (if applicable) Mechanical: (if applicable) No. Fixture Tvve No. Fixture Tvae No. Fixture Tune Sprinkler Heads Water Closet (toilet) Furnace Other/Special FS Device Bathtub Gas Meter Lavatory (wash basin) Range Hood Shower Gas Range Kitchen Sink Water Heater Dishwasher Air Conditioning Laundry Tub 1tlech. Fireplace Fire Alarm: (if applicable) Clothes Washer Bathroon(s) Rrhaust Fait Rater Heater Air Exchanger No. Fixture Tvpe Urinal Dryer Drinking Fountain Gas Opening silo Fixture Floor Drain of Devices Slop Sink Other Hydrants TOTAL TOTAL S9 Per Fixture) 59 Per Fhture) FEES: Bldg. Permit Plan Review State Surcharge Plmg. Permit Fixtures Surcharge Mech. Permit Fixtures Surcharge Sewer Access Water Access Water. Meter. Meter Sales Tax Sew & Water Permit Trunk Water Trunk Sanitary Sewer Trunk Storm Sewer Lift Station TOTAL FEES: FOR CITY USE QNLY: Tree Ordinance Handout Yes No Other Handouts Yes No Bldg. Total ADDITIONAL INFORMATION: f Valuation: 1 ' 3 006 Plmg. Total Construction Type: Occupancy Group: Division: Square Footage: Mech. Total # of Stories: of Residential Units: Maximum Occupancy: Di -is P) R: M4- A Fire Sprinklers: U Yes CJ No Off -Street Parking Covered: Meter Total. Off -Street Parking Uncovered: Building Official l 2/ /' BPT: I / mc 0 Midwest Area Tel (724) 416-2096CR E Crown Castle Fax (724) 416-4096 2000 Corporate Drive Fax Canonsburg, PA 15317 September 10, 2012 City of Monticello 505 Walnut Street, Suite 1 Monticello, MN 55362 RE: Tower Site: SPRINT NV MS57XC757 Located at: 406 East 7th Street, Monticello, MN 55362 Site #: 878532 / MS57XC757 Dear Building Inspector: Crown Castle would like to apply for a Building Permit and Electrical Permit for tower site located at: 406 East 7th Street, Monticello, MN 55362. As part of the application process, Crown wants to assure the City of Elkhart that, to the best of its knowledge based upon our records, the Wireless Communication Facility has not been modified in any material way since its initial construction and that it is structurally sound. Further, to the best of Crown's knowledge, the Wireless Communication Facility and site compound have been maintained in a good and safe condition. Crown will continue to maintain the site as required by the terms of the Ground Lease Agreement, and all amendments thereto and in accordance with industry standards. The scope of work we are proposing is the following: 1-2 new cabinets will be placed within the existing Sprint lease are. Adding 3 new antennas 6 RRU's 3 Lines of Coax Existing CDMA equipment to remain for an "interim" period of 6-12 months. After that time, - existing CDMA equipment will come down and proposed NV equip0ment (listed above) will become the "final configuration". Please call or email me with the fee amounts that will be required for these permits. I will then overnight a check to you and will include a return package for you to return the permits in. I can be reached at 724- 416-2096 or heather.wilsonCED=wncastle.com. /ia"^`^ h,rn,, 0-, 9/a!o/1 - Crown would like to thank you for your assistance with this matter and for your prompt attention in the review. Crown looks forward to hearing from you soon. Sincerely, Heather B. Wilson Property Specialist, Midwest Ar SEPU.012 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 — Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations APPROVED FILE COPY REVIEWED FOR CODE COMPLIANCE SUBJECT TO FIELD INSPECTION Date:9 9 -2. signe dn tnxTower Report - version 6.0.4.0 Date: July 18, 2012 V I CCATLE Branden Woodard Crown Castle Crown Castle 2000 Corporate Drive 2000 Corporate Drive Canonsburg, PA 15317 Canonsburg, PA 15317 (724) 416-2000 Subject: Structural Analysis Report Carrier Designation: Sprint PCS Co -Locate —Interim Load Carrier Site Number: MS57XC757 Carrier Site Name: N/A Crown Castle Designation. Crown Castle BU Number: 878532 Crown Castle Site Name: F1/MONTICELLO/FULFILLMENT SYST Crown Castle JDE Job Number: 175816 Crown Castle Work Order Number: 511647 Crown Castle Application Number: 149920 Rev. 0 Engineering Firm Designation: Crown Castle Project Number: 511647 Site Data: 406 EAST 7TH STREET, MONTICELLO, Wright County, MN Latitude 45° 97'53.22", Longitude-93047132.84" 159 Foot - Monopole Tower Dear Branden Woodard, Crown Castle is pleased to submit this "Structural Analysis Report" to determine the structural Integrity of the above mentioned tower. This analysis has been performed In accordance with the Crown Castle Structural Statement of Work' and the terms of Crown Castle Purchase Order Number 511647, in accordance with application 149920, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined.the tower_ stress -level forthe structure and foundation, under the following load case, to` -be" _ CLC5: Existing + Proposed Equipment tSufficlent Capacity Note: See Table-l-and,Table II"for- theproposed and existing loading, respectively. J The analysis has been performed In accordance with the TIA/EIA-222-F standard and local code requirements based upon a wind speed of 80 mph fastest mile. All modifications and equipment proposed in this report shall be Installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at Crown Castle appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Structural analysis prepared by: Calvin Straub, E.I.T. / M.B Respectfully submitted by: \\ Q: LICENSED PROFESSIONAL i Reza Jenabzadeh, P.E. = ENGINEER Engineer II lo A I j''••q•••••'''•' o tnxTower Report - version 6.0.4.0ij lotit%%• gROP ssIONALENGfNEER 1 hereby certlty that this plan, specification, or report was prepared by me or under my direct supervision and that i am a duty Licensed Professional Engineer under the law of the State of Minnesota. Print Name: Re lenabt}eh Signature: Date: 7/— 1 U 6f License R aagay 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 1) INTRODUCTION July 18, 2012 CC/ BU No 878532 Page 3 This tower is a 159 ft Monopole tower designed by ENGINEERED ENDEAVORS, INC. in April of 2003. The tower was originally designed for a wind speed of 85 mph per TIA/EIA-222-F.The tower has been modified per reinforcement drawings prepared by GPD Associates, Inc, in April of 2008. Reinforcement consists of addition of base plate stiffeners. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA/EIA-222-F Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a fastest mile wind speed of 80 mph with no ice, 37.1 mph with 0.75 inch ice thickness and 50 mph under service loads. Table 1 - Proposed Antenna and Cable Information Center Mounting Line Number Antenna Number Feed Level (ft) Elevation of Manufacturer Antenna Model of Feed Line Note ft) Antennas Lines Size (in) 1 powerwave P65-16-XLPP-RR w/ technologies Mount Pipe 2 powerwave ( P90-15-XLPP-RR w/ technologies Mount Pipe 155.0 157.0 3 1-1/4 - 3 samsung telecommunications RRH-C2A w/EXT FILTER 3 samsung RRH-P4 telecommunications Table 2 - Existing Antenna and Cable Information Center Number Mounting Line of Antenna Antenna ModelLevel (ft) Elevation Antennas Manufacturer ft) 157.0 6 ems wireless IFV65-14-ONA2 w/ Mount 155.0 Pipe 155.0 1 tower mounts T-Arm Mount [TA 601-3] 142.0 9 I andrew TMBX-6517-R2M w/ Mount Pipe 140.0 6 andrew ETT19V2S12UB 140.0 1 ( tower mounts 1PIatform Mount [LP 303-1] 123.0 6 I powerwave RA21.7770.00 w/ Mount technologies Pipe 120.0 12 I andrew 641280-DF 120.0 1 tower mounts IPlatform Mount [LP 701-1] Notes: 1) Existing Equipment Number Feed of Feed Line Note Lines Size (in), 6 1-5/8 1 18 1-5/8 1 12 1-5/8 1 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Table 3 - Design Antenna and Cable Information Center Number Mounting Line of Antenna Level (ft) Elevation Antennas Manufacturer ft) 160 160 12 dapa 140 140 12 dapa 120 120 12 dapa 100 100 12 dapa 80 80 12 dapa 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document 4-GEOTECHNICAL REPORTS 4-POST-MODIFICATION INSPECTION 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 4-TOWER MANUFACTURER DRAWINGS 4-TOWER REINFORCEMENT DESIGN/DRAWINGS/DATA Remarks Terracon GPD Associates, Inc. July 18, 2012 CC/ BU No 878532 Page 4 Number Feed Antenna Model of Feed Line Lines Size (in) 48000 - - 48000 - - 48000 - - 48000 - - 48000 - - Engineered Endeavors, Inc. Engineered Endeavors, Inc. GPD Associates, Inc. Reference Source 1504987 CCISITES 2286749 CCISITES 1621567 CCISITES 1617475 CCISITES 2231372 CCISITES 3.1) Analysis Method tnxTower (version 6.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) When applicable, transmission cables are considered as structural components for calculating wind loads as allowed by TIA/EIA-222-F. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 5 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Section Elevation (ft) Component Size Critical P (K) SF*P allow Pass / Fail No. Type Element K) Capacity L1 1159 - 133.42 Pole TP21.29x16x0.1875 1 3.20 632.62 46.0 Pass L2 3 837 Pole TP30.21x20.260lx0.25 2 10.35 1199.42 101.5 Passe L3 87.837- Pole TP38.8x28.8256x0.3125 3 17.52 1927.60 103.8 Passe 43.2903 L4 143.2903 - 0 Pole TP47x37.0697x0.375 4 28.76 2885.04 94.3 Pass Summary Pole (1-3) 103.8 Passz I Rating = 103.8 Pass Table 6 - Tower Component Stresses vs. Capacity Notes I Component I Elevation (ft) I Capacity I Pass / Fail 1 Anchor Rods 0 ( 93.3 Pass 1 Base Plate 0 97.0 Pass 1 Base Foundation 0 ( 77.8 Pass Structure Rating (max from all components) = I 103.8%2 Notes: 1) See additional documentation in "Appendix C — Additional Calculations" for calculations supporting the % capacity consumed. 2) Capacities up to 105% are considered acceptable based on analysis methods used. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing and proposed loads. No modifications are required at this time. tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 APPENDIX A TNXTOWER OUTPUT July 18, 2012 CC/ BU No 878532 Page 6 tnxTower Report - version 6.0.4.0 n MCl p s N O OJ O N N R O O N C) m os ID O N l7 m Co e m ori o I ri 133.4 it 87.88 it w Nt` NQ O N 43.3it ,.. 0.0 it v m y& co N Z N f$ .2 a 3 T C_177 1 I_LC L S ZLI[`iCr I TYPE ELEVATION TYPE ELEVATION I 1(2)FV65.14-WNA2 w/Mount Pipe 155 2)E1T19V2S12U8 14011401(2) FV65.14.00NA2 w/ Mount Pipe 155 2) ETT19V2S12U8 1(2) FV65-14-00NA2 w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 1140 1 P90.15-XLPP-RR w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 1140 1 P65-16-XLPP-RR w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 140 1 P90-15-XLPP-RR w/ Mount Pipe 155 Platform Mount ILP 303-11 140 I I RRH-C2A w/EXT FILTER 155 2) RA21.7770.00 w/ Mount Pipe 120 I 1 RRH-C2A w/EXT FILTER 1155 2) RA21.7770.00 w/ Mount Pipe 120 1 I RRH-C2A w/EXT FILTER 1 155 21 RA21.7770.00 w/ Mount Pipe 120 I I RRH-P4 1155 4) 641280-DF 1120 1 1 RRH-P4 1155 4) 641280-DF 1120 1 RRH-P4 1155 4) 6412MDF 1120 1 T-Arm Mount ITA 6o1-31 1155 Platform Mount ILP 701-11 1120 1 18'x2" Antenna Mount Pipe 1155 2) Tx2- Antenna Mount Pipe 10 1 I B'x2' Antenna Mount Pipe 1 155 2) Tx2' Antenna Mount Pipe 10 1 18'x2' Antenna Mount Pipe 1 155 2) Tx2' Antenna Mount Pipe 10 1 1(2) ETT79V2Sl2UB 1140 4) Tx2' Antenna Mount Pipe 10 1 MATERIAL STRENGTH I GRADE I Fy I Fu I GRADE I Fy I Fu I I A572.65 65 ksi j 80 ksl TOWER DESIGN NOTES 1. Tower is located in Wright County, Minnesota. 2. Tower designed for a 80 mph basic wind in accordance with the TIA/EIA-222-F Standard. 3. Tower is also designed for a 37 mph basic wind with 0.75 in ice. Ice is considered to increase in thickness with height. 4. Deflections are based upon a 50 mph wind. 5. TOWER RATING: 103.8% AXIAL 49 KK SHEAR I \ MOMENT 7 K ` 762 kip-ft TORQUE 0 kip-ft 37 mph WIND - 0.7500 in ICE AXIAL 29 K SHEA MOMENT 24 K ` 2580 kip-ft TORQUE 1 kip-ft REACTIONS - 80 mph WIND Crown Castle 1o" BU# 878532 CRO N 2000 Corporate Drive Prpie<t: II CASE Canonsburg PA 15317 Client: Crown Castle Drawn by: CStraub Appd' We Are solutions Phone: (724) 416-2000 fie' TIA/EIA-222-F I Data:07/18/12 scale: NTS FAX: (724) 416-2254 Path' RASA Models -LettmWo k AreMGSJraub%E7e532X97e532. thug No. E-1 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Tower Input Data July 18, 2012 CCI BU No 878532 Page 7 There is a pole section. This tower is designed using the TIA/EIA-222-F standard. The following design criteria apply: 2) Tower is located in Wright County, Minnesota. 3) Basic wind speed of 80 mph. 4) Nominal ice thickness of 0.7500 in. 5) Ice thickness is considered to increase with height. 6) Ice density of 56 pcf. 7) A wind speed of 37 mph is used in combination with ice. 8) Temperature drop of 50 OF. 9) Deflections calculated using a wind speed of 50 mph. 10) A non -linear (P-delta) analysis was used. 11) Pressures are calculated at each section. 12) Stress ratio used in pole design is 1.333. 13) Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification 4 Use Code Stress Ratios 4 Use Code Safety Factors - Guys 4 Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Options Distribute Leg Loads As Uniform Assume Legs Pinned 4 Assume Rigid Index Plate 4 Use Clear Spans For Wind Area Use Clear Spans For KL/r Retension Guys To Initial Tension 4 Bypass Mast Stability Checks 4 Use Azimuth Dish Coefficients 4 Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feedline Bundles As Cylinder Use ASCE 10 X-Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check Poles l Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 159.00-133.42 25.58 3.17 18 16.0000 21.2900 0.1875 0.7500 A572-65 65 ksi) L2 133.42-87.84 48.75 4.33 18 20.2601 30.2100 0.2500 1.0000 A572-65 65 ksi) L3 87.84-43.29 48.88 5.42 18 28.8256 38.8000 0.3125 1.2500 A572-65 65 ksi) L4 43.29-0.00 48.71 18 37.0697 47.0000 0.3750 1.5000 A572-65 65 ksi) Tapered Pole Properties Section Tip Dia. Area I r C in in2 in° in in L1 16.2468 9.4104 297.2674 5.6134 8.1280 I/C J It/Q w w/t in' W in2 in 36.5733 594.9259 4.7061 2.4860 13.259 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 July 18, 2012 CCI BU No 878532 Page 8 Section Tip Dia. Area I r C I/C J IVQ w w/t in inZ in' in in 0 W inZ in 21.6184 12.5586 706.5573 7.4914 10.8153 65.3293 1414.0443 6.2805 3.4170 18.224 L2 21.2290 15.8780 803.2105 7.1036 10.2921 78.0414 1607.4779 7.9405 3.1258 12.503 30.6760 23.7733 2695.9374 10.6358 15.3467 175.6691 5395.4222 11.8889 4.8770 19.508 L3 30.1681 28.2814 2904.8668 10.1221 14.6434 198.3740 5813.5559 14.1434 4.5233 14.475 39.3986 38.1748 7144.1983 13.6631 19.7104 362.4583 14297.797 19.0910 6.2788 20.092 1 L4 38.7629 43.6758 7429.9282 13.0266 18.8314 394.5501 14869.632 21.8421 5.8643 15.638 8 47.7251 55.4954 15241.656 16.5519 23.8760 638.3673 30503.368 27.7530 7.6120 20.299 7 7 Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt per face) Ar Spacing Spacing Diagonals Horizontals ft to in in in L1 159.00- 1 1 1 133.42 L2 133.42- 1 1 1 87.84 L3 87.84- 1 1 1 43.29 L4 43.29-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leq ft ft2/ft o/f LDF7-50A(1-5/8") C No Inside Pole 155.00 - 0.00 6 No Ice 0.00 0.82 1/2" Ice 0.00 0.82 1" Ice 0.00 0.82 2" Ice 0.00 0.82 4" Ice 0.00 0.82 TYPE 5( 1 1/4") C No CaAa (Out Of 155.00 - 0.00 3 No Ice 0.00 1.10 Face) 1/2" Ice 0.00 2.18 1" Ice 0.00 3.86 2" Ice 0.00 9.07 4" Ice 0.00 26.81 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 3 No Ice 0.20 0.70 Face) 1/2" Ice 0.30 2.23 1" Ice 0.40 4.38 2" Ice 0.60 10.50 4" Ice 1.00 30.07 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 15 No Ice 0.00 0.70 Face) 1/2" Ice 0.00 2.23 1" Ice 0.00 4.38 2" Ice 0.00 10.50 4" Ice 0.00 30.07 LDF7-50A(1-5/8") C No Inside Pole 120.00 - 0.00 12 No Ice 0.00 0.82 1/2" Ice 0.00 0.82 1" Ice 0.00 0.82 2" Ice 0.00 0.82 4" Ice 0.00 0.82 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation /n Face Out Face n ft ftz ft2 fe fe K L1 159.00-133.42 A 0.000 0.000 0.000 0.000 0.00 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 9 Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft, K B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 3.968 0.26 L2 133.42-87.84 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 27.487 1.27 L3 87.84-43.29 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 26.862 1.37 L4 43.29-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 26.104 1.33 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Lea in ft2 ft2 ft2 ft2 K L1 159.00-133.42 A 0.896 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 7.506 0.80 L2 133.42-87.84 A 0.866 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 51.999 4.25 L3 87.84A3.29 A 0.814 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 50.013 4.16 L4 43.29-0.00 A 0.750 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 47.241 3.85 Feed Line Center of Pressure Section Elevation CPX CPZ CPX CPZ Ice Ice ft in in in in L1 159.00-133.42 0.2025 0.1169 0.3279 0.1893 L2 133.42-87.84 0.6105 0.3525 0.9229 0.5328 L3 87.84-43.29 0.6467 0.3734 1.0101 0.5832 L4 43.29-0.00 0.6696 0.3866 1.0534 0.6082 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ft 2) FV65-14-OONA2 w/ A From Leg 4.00 0.0000 155.00 No Ice 8.64 6.95 0.06 Mount Pipe 0.00 1/2" 9.29 8.13 0.12 2.00 Ice 9.91 9.02 0.20 1" Ice 11.18 10.84 0.38 2" Ice 13.83 14.85 0.89 4" Ice 2) FV65-14-OONA2 w/ B From Leg 4.00 0.0000 155.00 No Ice 8.64 6.95 0.06 Mount Pipe 0.00 1/2" 9.29 8.13 0.12 2.00 Ice 9.91 9.02 0.20 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Description Face Offset Offsets: Azimuth Placement CAAA or Type Horz Adjustmen Front Leg Lateral t Vert ft ft ft2 ft e ft 1" Ice 11.18 2" Ice 13.83 2) FV65-14-OONA2 w/ C From Leg 4.00 0.0000 Mount Pipe 0.00 2.00 P90-15-XLPP-RR w/ A From Leg 4.00 0.0000 Mount Pipe 0.00 2.00 P65-16-XLPP-RR w/ B From Leg 4.00 0.0000 Mount Pipe 0.00 2.00 P90-15-XLPP-RR w/ C From Leg 4.00 0.0000 Mount Pipe 0.00 2.00 RRH-C2A WEXT FILTER A From Leg 4.00 0.0000 0.00 2.00 RRH-C2A WEXT FILTER B From Leg 4.00 0.0000 0.00 2.00 RRH-C2A WEXT FILTER C From Leg 4.00 0.0000 0.00 2.00 RRH-P4 A From Leg 4.00 0.0000 0.00 2.00 RRH-P4 B From Leg 4.00 0.0000 0.00 2.00 RRH-P4 C From Leg 4.00 0.0000 0.00 2.00 T-Arm Mount [TA 601-3] C None 0.0000 tnxTower Report - version 6.0.4.0 4" Ice 155.00 No Ice 8.64 1/2" 9.29 Ice 9.91 1" Ice 11.18 2" Ice 13.83 4" Ice 155.00 No Ice 8.64 1/2" 9.29 Ice 9.91 1" Ice 11.18 2" Ice 13.83 4" Ice 155.00 No Ice 8.64 1/2" 9.29 Ice 9.91 1" Ice 11.18 2" Ice 13.83 4" Ice 155.00 No Ice 8.64 1/2" 9.29 Ice 9.91 1" Ice 11.18 2" Ice 13.83 4" Ice 155.00 No Ice 3.63 1/2" 3.89 Ice 4.16 1" Ice 4.72 2" Ice 5.95 4" Ice 155.00 No Ice 3.63 1/2" 3.89 Ice 4.16 1" Ice 4.72 2" Ice 5.95 4" Ice 155.00 No Ice 3.63 1/2" 3.89 Ice 4.16 1" Ice 4.72 2" Ice 5.95 4" Ice 155.00 No Ice 3.19 1/2" 3.44 Ice 3.70 1" Ice 4.24 2" Ice 5.42 4" Ice 155.00 No Ice 3.19 1/2" 3.44 Ice 3.70 1" Ice 4.24 2" Ice 5.42 4" Ice 155.00 No Ice 3.19 1/2" 3.44 Ice 3.70 1" Ice 4.24 2" Ice 5.42 4" Ice 155.00 No Ice 10.90 1/2" 14.65 July 18, 2012 CCI BU No 878532 Page 10 CAAA Weight Side fe K 10.84 0.38 14.85 0.89 6.95 0.06 8.13 0.12 9.02 0.20 10.84 0.38 14.85 0.89 6.36 0.07 7.54 0.13 8.43 0.21 10.24 0.38 14.10 0.88 6.36 0.07 7.54 0.14 8.43 0.21 10.24 0.39 14.10 0.88 6.36 0.07 7.54 0.13 8.43 0.21 10.24 0.38 14.10 0.88 1.55 0.06 1.75 0.08 1.96 0.10 2.41 0.16 3.40 0.33 1.55 0.06 1.75 0.08 1.96 0.10 2.41 0.16 3.40 0.33 1.55 0.06 1.75 0.08 1.96 0.10 2.41 0.16 3.40 0.33 2.07 0.06 2.29 0.08 2.52 0.11 2.99 0.17 4.05 0.35 2.07 0.06 2.29 0.08 2.52 0.11 2.99 0.17 4.05 0.35 2.07 0.06 2.29 0.08 2.52 0.11 2.99 0.17 4.05 0.35 10.90 0.73 14.65 0.93 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft fe ft, ft ft Ice 18.40 18.40 1" Ice 25.90 25.90 2" Ice 40.90 40.90 4" Ice 8'x2" Antenna Mount Pipe A From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.00 1/2" 2.73 2.73 0.00 Ice 3.40 3.40 1" Ice 4.40 4.40 2" Ice 6.50 6.50 4" Ice 8'x2" Antenna Mount Pipe B From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.00 1/2" 2.73 2.73 0.00 Ice 3.40 3.40 1" Ice 4.40 4.40 2" Ice 6.50 6.50 4" Ice 8'x2" Antenna Mount Pipe C From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.00 1/2" 2.73 2.73 0.00 Ice 3.40 3.40 1" Ice 4.40 4.40 2" Ice 6.50 6.50 4" Ice 2) ETT19V2S12UB A From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.00 1/2" 0.78 0.41 0.00 Ice 0.90 0.50 1" Ice 1.17 0.72 2" Ice 1.81 1.27 4" Ice 2) ETT19V2S12UB B From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.00 1/2" 0.78 0.41 0.00 Ice 0.90 0.50 1" Ice 1.17 0.72 2" Ice 1.81 1.27 4" Ice 2) ETT19V2S12UB C From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.00 1/2" 0.78 0.41 0.00 Ice 0.90 0.50 1" Ice 1.17 0.72 2" Ice 1.81 1.27 4" Ice 3) TMBX-6517-R2M w/ A From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 Mount Pipe 0.00 1/2" 6.88 7.00 2.00 Ice 7.48 8.15 1" Ice 8.67 10.16 2" Ice 11.14 14.39 4" Ice 3) TMBX-6517-R2M w/ B From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 Mount Pipe 0.00 1/2" 6.88 7.00 2.00 Ice 7.48 8.15 1" Ice 8.67 10.16 2" Ice 11.14 14.39 4" Ice 3) TMBX-6517-R2M w/ C From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 Mount Pipe 0.00 1/2" 6.88 7.00 2.00 Ice 7.48 8.15 1" Ice 8.67 10.16 2" Ice 11.14 14.39 4" Ice Platform Mount [LP 303-1] C None 0.0000 140.00 No Ice 14.66 14.66 1/2" 18.87 18.87 Ice 23.08 23.08 1" Ice 31.50 31.50 2" Ice 48.34 48.34 4" Ice July 18, 2012 CCI BU No 878532 Page 11 Weight K 1.13 1.52 2.32 0.03 0.04 0.06 0.12 0.30 0.03 0.04 0.06 0.12 0.30 0.03 0.04 0.06 0.12 0.30 0.01 0.02 0.02 0.04 0.10 0.01 0.02 0.02 0.04 0.10 0.01 0.02 0.02 0.04 0.10 0.04 0.09 0.15 0.30 0.75 0.04 0.09 0.15 0.30 0.75 0.04 0.09 0.15 0.30 0.75 1.25 1.48 1.71 2.18 3.10 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft It ft, fe K ft ft 2) RA21.7770.00 w/ A From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ B From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ C From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 4) 641280-DF A From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF B From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF C From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice Platform Mount [LP 701-1] C None 0.0000 120.00 No Ice 59.15 59.15 2.75 1/2" 71.12 71.12 3.42 Ice 83.09 83.09 4.10 1" Ice 107.03 107.03 5.45 2" Ice 154.91 154.91 8.15 4" Ice 2) 7'x2" Antenna Mount A From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) 7'x2" Antenna Mount B From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) 7'x2" Antenna Mount C From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 4) 7'x2" Antenna Mount C From Face 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Description Face Offset Offsets: Azimuth Placement or Type Horz Adjustmen Leg Lateral t Vert ft ft ft ° ft Comb. No. 1 Dead Only 2 Dead+Wind 0 deg - No Ice 3 Dead+Wind 30 deg - No Ice 4 Dead+Wind 60 deg - No Ice 5 Dead+Wind 90 deg - No Ice 6 Dead+Wind 120 deg - No Ice 7 Dead+Wind 150 deg - No Ice 8 Dead+Wind 180 deg - No Ice 9 Dead+Wind 210 deg - No Ice 10 Dead+Wind 240 deg - No Ice 11 Dead+Wind 270 deg - No Ice 12 Dead+Wind 300 deg - No Ice 13 Dead+Wind 330 deg - No Ice 14 Dead+Ice+Temp 15 Dead+Wind 0 deg+Ice+Temp 16 Dead+Wind 30 deg+Ice+Temp 17 Dead+Wind 60 deg+Ice+Temp 18 Dead+Wind 90 deg+Ice+Temp 19 Dead+Wind 120 deg+Ice+Temp 20 Dead+Wind 150 deg+Ice+Temp 21 Dead+Wind 180 deg+lce+Temp 22 Dead+Wind 210 deg+Ice+Temp 23 Dead+Wind 240 deg+Ice+Temp 24 Dead+Wind 270 deg+Ice+Temp 25 Dead+Wind 300 deg+Ice+Temp 26 Dead+Wind 330 deg+Ice+Temp 27 Dead+Wind 0 deg - Service 28 Dead+Wind 30 deg - Service 29 Dead+Wind 60 deg - Service 30 Dead+Wind 90 deg - Service 31 Dead+Wind 120 deg - Service 32 Dead+Wind 150 deg - Service 33 Dead+Wind 180 deg - Service 34 Dead+Wind 210 deg - Service 35 Dead+Wind 240 deg - Service 36 Dead+Wind 270 deg - Service 37 Dead+Wind 300 deg - Service 38 Dead+Wind 330 deg - Service Sectio Elevation Component n ft Type No. L1 159 - 133.42 Pole Load Combinations Description July 18, 2012 CCI BU No 878532 Page 13 CAAA CAAA Weight Front Side fe ft, K 2" Ice 5.58 5.58 0.27 4" Ice Maximum Member Forces Condition Gov. Force Load Comb. K Max Tension 36 0.00 Max. Compression 14 8.61 Max. Mx 11 3.20 Max. My 8 3.20 Major Axis Minor Axis Moment Moment kip-ft kip-ft 0.00 0.00 0.50 0.32 120.63 0.06 0.11 120.59 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Sectio Elevation n It No. L2 133.42 - 87.837 L3 87.837 - 43.2903 L4 43.2903 - 0 Component Type Pole Pole Pole Condition Max. Vy Max. Vx Max. Torque Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max. Torque Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max. Torque Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max. Torque July 18, 2012 CCI BU No 878532 Page 14 Gov. Force Major Axis Minor Axis Load Moment Moment Comb. K kin-ft kip-ft 11 9.02 120.63 0.06 8 9.02 0.11 120.59 13 0.02 1 0.00 0.00 0.00 14 21.98 4.13 2.42 11 10.35 720.38 0.44 8 10.35 0.77 720.06 11 16.75 720.38 0.44 8 16.75 0.77 720.06 13 0.21 1 0.00 0.00 0.00 14 32.88 8.72 5.07 11 17.52 1522.51 0.95 8 17.52 1.64 1521.82 11 20.05 1522.51 0.95 8 20.05 1.64 1521.82 13 0.42 1 0.00 0.00 0.00 14 48.76 14.37 8.70 11 29.06 2579.51 1.87 8 29.06 2.83 2578.56 11 23.71 2579.51 1.87 8 23.71 2.83 2578.56 6 0.90 Maximum Reactions Location Condition Gov. Vertical Horizontal, X Horizontal, Z Load K K K Comb. Pole Max. Vert 24 48.76 6.52 0.00 Max. H. 11 29.09 23.68 0.00 Max. Hz 2 29.09 0.00 23.68 Max. Mx 2 2574.84 0.00 23.68 Max. M. 5 2573.88 23.68 0.00 Max. Torsion 12 0.90 20.51 11.84 Min. Vert 1 29.09 0.00 0.00 Min. H. 5 29.09 23.68 0.00 Min. Hz 8 29.09 0.00 23.68 Min. Mx 8 2578.56 0.00 23.68, Min. M. 11 2579.51 23.68 0.00 Min. Torsion 6 0.90 20.51 11.84 Tower Mast Reaction Summary Load Vertical Shear, Shearz Overturning Overturning Torque Combination Moment, M. Moment, M. K K K kip-ft kip-ft kip-ft Dead Only 29.09 0.00 0.00 1.84 2.78 0.00 Dead+Wind 0 deg - No Ice 29.09 0.00 23.68-2574.84 2.83 0.59 Dead+Wind 30 deg - No Ice 29.09 11.84 20.51-2229.63 1285.53 0.16 Dead+Wind 60 deg - No Ice 29.09 20.51 11.84-1286.49 2228.67 0.31 Dead+Wind 90 deg - No Ice 29.09 23.68 0.00 1.87 2573.88 0.70 Dead+Wind 120 deg - No Ice 29.09 20.51 11.84 1290.22 2228.66 0.90 Dead+Wind 150 deg - No Ice 29.09 11.84 20.51 2233.35 1285.52 0.86 Dead+Wind 180 deg - No Ice 29.09 0.00 23.68 2578.56 2.83 0.59 Dead+Wind 210 deg - No Ice 29.09 11.84 20.51 2233.34 1291.17 0.16 Dead+Wind 240 deg - No Ice 29.09 20.51 11.84 1290.21 2234.30 0.31 Dead+Wind 270 deg - No Ice 29.09 23.68 0.00 1.87 2579.51 0.70 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 July 18, 2012 CCI BU No 878532 Page 15 Load Vertical Shear, Shear, Overturning Overturning Torque Combination Moment, Mx Moment, M. K K K kio-ft kin-ft kio-ft Dead+Wind 300 deg - No Ice 29.09 20.51 11.84 1286.48 2234.31 0.90 Dead+Wind 330 deg - No Ice 29.09 11.84 20.51 2229.62 1291.18 0.86 Dead+Ice+Temp 48.76 0.00 0.00 8.70 14.37 0.00 Dead+Wind 0 48.76 0.00 6.52 736.66 14.40 0.25 deg+Ice+Temp Dead+Wind 30 48.76 3.26 5.64 636.81 358.30 0.08 deg+Ice+Temp Dead+Wind 60 48.76 5.64 3.26 363.98 631.13 0.10 deg+Ice+Temp Dead+Wind 90 48.76 6.52 0.00 8.72 730.98 0.26 deg+Ice+Temp Dead+Wind 120 48.76 5.64 3.26 381.41 631.13 0.35 deg+Ice+Temp Dead+Wind 150 48.76 3.26 5.64 654.24 358.29 0.35 deg+Ice+Temp Dead+Wind 180 48.76 0.00 6.52 754.09 14.40 0.25 deg+Ice+Temp Dead+Wind 210 48.76 3.26 5.64 654.23 387.09 0.08 deg+Ice+Temp Dead+Wind 240 48.76 5.64 3.26 381.41 659.92 0.10 deg+Ice+Temp Dead+Wind 270 48.76 6.52 0.00 8.72 759.77 0.26 deg+Ice+Temp Dead+Wind 300 48.76 5.64 3.26 363.97 659.92 0.35 deg+Ice+Temp Dead+Wind 330 48.76 3.26 5.64 636.80 387.09 0.35 deg+Ice+Temp Dead+Wind 0 deg - Service 29.09 0.00 9.25 1007.36 2.84 0.23 Dead+Wind 30 deg - Service 29.09 4.63 8.01 872.15 501.78 0.06 Dead+Wind 60 deg - Service 29.09 8.01 4.63 502.75 871.19 0.12 Dead+Wind 90 deg - Service 29.09 9.25 0.00 1.88 1006.39 0.27 Dead+Wind 120 deg - 29.09 8.01 4.63 506.50 871.19 0.35 Service Dead+Wind 150 deg - 29.09 4.63 8.01 875.90 501.78 0.34 Service Dead+Wind 180 deg - 29.09 0.00 9.25 1011.10 2.84 0.23 Service Dead+Wind 210 deg - 29.09 4.63 8.01 875.90 507.46 0.06 Service Dead+Wind 240 deg - 29.09 8.01 4.63 506.49 876.87 0.12 Service Dead+Wind 270 deg - 29.09 9.25 0.00 1.88 1012.07 0.27 Service Dead+Wind 300 deg - 29.09 8.01 4.63 502.74 876.87 0.35 Service Dead+Wind 330 deg - 29.09 4.63 8.01 872.15 507.46 0.34 Service Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ Error Comb. K K K K K K 1 0.00 29.09 0.00 0.00 29.09 0.00 0.000% 2 0.00 29.09 23.68 0.00 29.09 23.68 0.000% 3 11.84 29.09 20.51 11.84 29.09 20.51 0.000% 4 20.51 29.09 11.84 20.51 29.09 11.84 0.000% 5 23.68 29.09 0.00 23.68 29.09 0.00 0.000% 6 20.51 29.09 11.84 20.51 29.09 11.84 0.000% 7 11.84 29.09 20.51 11.84 29.09 20.51 0.000% 8 0.00 29.09 23.68 0.00 29.09 23.68 0.000% 9 -11.84 29.09 20.51 11.84 29.09 20.51 0.000% 10 -20.51 29.09 11.84 20.51 29.09 11.84 0.000% 11 -23.68 29.09 0.00 23.68 29.09 0.00 0.000% 12 -20.51 29.09 11.84 20.51 29.09 11.84 0.000% 13 -11.84 29.09 20.51 11.84 29.09 20.51 0.000% tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 16 Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ Error Comb. K K K K K K 14 0.00 48.76 0.00 0.00 48.76 0.00 0.000% 15 0.00 48.76 6.52 0.00 48.76 6.52 0.000% 16 3.26 48.76 5.64 3.26 48.76 5.64 0.000% 17 5.64 48.76 3.26 5.64 48.76 3.26 0.000% 18 6.52 48.76 0.00 6.52 48.76 0.00 0.000% 19 5.64 48.76 3.26 5.64 48.76 3.26 0.000% 20 3.26 48.76 5.64 3.26 48.76 5.64 0.000% 21 0.00 48.76 6.52 0.00 48.76 6.52 0.000% 22 3.26 48.76 5.64 3.26 48.76 5.64 0.000% 23 5.64 48.76 3.26 5.64 48.76 3.26 0.000% 24 6.52 48.76 0.00 6.52 48.76 0.00 0.000% 25 5.64 48.76 3.26 5.64 48.76 3.26 0.000% 26 3.26 48.76 5.64 3.26 48.76 5.64 0.000% 27 0.00 29.09 9.25 0.00 29.09 9.25 0.000% 28 4.63 29.09 8.01 4.63 29.09 8.01 0.000% 29 8.01 29.09 4.63 8.01 29.09 4.63 0.000% 30 9.25 29.09 0.00 9.25 29.09 0.00 0.000% 31 8.01 29.09 4.63 8.01 29.09 4.63 0.000% 32 4.63 29.09 8.01 4.63 29.09 8.01 0.000% 33 0.00 29.09 9.25 0.00 29.09 9.25 0.000% 34 4.63 29.09 8.01 4.63 29.09 8.01 0.000% 35 8.01 29.09 4.63 8.01 29.09 4.63 0.000% 36 9.25 29.09 0.00 9.25 29.09 0.00 0.000% 37 8.01 29.09 4.63 8.01 29.09 4.63 0.000% 38 4.63 29.09 8.01 4.63 29.09 8.01 0.000% Non -Linear Convergence Results Load Converged? Number Displacement Force Combination of Cvcles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00003486 3 Yes 6 0.00000001 0.00017036 4 Yes 6 0.00000001 0.00017085 5 Yes 5 0.00000001 0.00002102 6 Yes 6 0.00000001 0.00017189 7 Yes 6 0.00000001 0.00017003 8 Yes 5 0.00000001 0.00003488 9 Yes 6 0.00000001 0.00017182 10 Yes 6 0.00000001 0.00017132 11 Yes 5 0.00000001 0.00002104 12 Yes 6 0.00000001 0.00017029 13 Yes 6 0.00000001 0.00017215 14 Yes 4 0.00000001 0.00009751 15 Yes 5 0.00000001 0.00049067 16 Yes 6 0.00000001 0.00012849 17 Yes 6 0.00000001 0.00012947 18 Yes 5 0.00000001 0.00048395 19 Yes 6 0.00000001 0.00013594 20 Yes 6 0.00000001 0.00013226 21 Yes 5 0.00000001 0.00050163 22 Yes 6 0.00000001 0.00014393 23 Yes 6 0.00000001 0.00014292 24 Yes 5 0.00000001 0.00050255 25 Yes 6 0.00000001 0.00013604 26 Yes 6 0.00000001 0.00013974 27 Yes 4 0.00000001 0.00038918 28 Yes 5 0.00000001 0.00049521 29 Yes 5 0.00000001 0.00049748 30 Yes 4 0.00000001 0.00036361 31 Yes 5 0.00000001 0.00050470 32 Yes 5 0.00000001 0.00049622 33 Yes 4 0.00000001 0.00039134 34 Yes 5 0.00000001 0.00050875 35 Yes 5 0.00000001 0.00050647 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 36 Yes 4 0.00000001 0.00036726 37 Yes 5 0.00000001 0.00049923 38 Yes 5 0.00000001 0.00050772 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. L1 159 - 133.42 60.630 35 3.4875 0.0012 L2 136.587 - 87.837 44.611 35 3.2608 0.0012 L3 92.1703 - 19.053 35 2.0939 0.0008 43.2903 L4 48.707 - 0 4.992 35 0.9602 0.0003 July 18, 2012 CC/ BU No 878532 Page 17 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in oIt 155.00 2) FV65-14-OONA2 w/ Mount 35 57.710 3.4583 0.0012 12799 Pipe 140.00 2) ETr19V2S12UB 35 46.966 3.3109 0.0012 3370 120.00 2) RA21.7770.00 w/ Mount Pipe 35 33.893 2.9055 0.0010 2444 0.00 2) 7'x2" Antenna Mount Pipe 0 0.000 0.0000 0.0000 20320 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. L1 159 - 133.42 153.849 11 8.8563 0.0031 L2 136.587 - 87.837 113.285 11 8.2833 0.0029 L3 92.1703 - 48.461 11 5.3259 0.0019 43.2903 L4 48.707 - 0 12.711 10 2.4448 0.0009 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in It 155.00 2) FV65-14-OONA2 w/ Mount 11 146.456 8.7826 0.0031 5258 Pipe 140.00 2) ETf19V2S12UB 11 119.251 8.4100 0.0030 1381 120.00 2) RA21.7770.00 w/ Mount Pipe 11 86.119 7.3835 0.0026 991 0.00 2) 7'x2" Antenna Mount Pipe 0 0.000 0.0000 0.0000 7989 Compression Checks tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Pole Design Data July 18, 2012 CCI BU No 878532 Page 18 Section Elevation Size L L Kl/r Fe A Actual Allow. Ratio No. P Pe P ft ft ft ksi inz K K p,, L1 159 - 133.42 TP21.29x16x0.1875 25.58 0.00 0.0 39.000 12.1689 3.20 474.58 0.007 1) L2 133.42- TP30.21x20.26014.25 48.75 0.00 0.0 39.000 23.0715 10.35 899.79 0.011 87.837(2) H1-3+VT (1.35 CR) - 2 L3 87.837 - TP38.8x28.8256x0.3125 48.88 0.00 0.0 39.000 37.0784 17.52 1446.06 0.012 43.2903(3) H1-3+VT (1.38 CR) - 3 L4 43.2903 - 0 (4) TP47x37.0697x0.375 48.71 0.00 0.0 39.000 55.4954 28.76 2164.32 0.013 Pole Bending Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. Mx fax Fax fbx My fby Fby fby ft kip-ft ksi ksi Fbx kip-ft ksi ksi Fbv L1 159 - 133.42 TP21.29x16x0.1875 120.65 23.611 39.000 0.605 0.00 0.000 39.000 0.000 1) L2 133.42- TP30.21x20.26010.25 720.50 52.270 39.000 1.340 0.00 0.000 39.000 0.000 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 1522.7 53.453 39.000 1.371 0.00 0.000 39.000 0.000 43.2903(3) 6 L4 43.2903 - 0 TP47x37.0697x0.375 2579.9 48.498 39.000 1.244 0.00 0.000 39.000 0.000 4) 5 Pole Shear Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. V fV Fv f T fW F,t f,, ft K ksi ksi F, kip-ft ksi ksi Fir L1 159 - 133.42 TP21.29x16x0.1875 9.02 0.742 26.000 0.057 0.00 0.000 26.000 0.000 1) L2 133.42- TP30.21x20.26014.25 16.75 0.726 26.000 0.056 0.00 0.000 26.000 0.000 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 20.05 0.541 26.000 0.042 0.00 0.000 26.000 0.000 43.2903(3) L4 43.2903 - 0 TP47x37.06974.375 23.25 0.419 26.000 0.032 0.00 0.000 26.000 0.000 4) Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P fbx fby f fVt Stress Stress It Pe Fbx Fbr F Fw Ratio Ratio L1 159 - 133.42 0.007 0.605 0.000 0.057 0.000 0.613 1.333 1) V H1-3+VT L2 133.42- 0.011 1.340 0.000 0.056 0.000 1.353 X 1.333 H1-3+VT 87.837(2) L3 87.837 - 0.012 1.371 0.000 0.042 0.000 1.383 1.333 H1-3+VT 43.2903(3) L4 43.2903 - 0 0.013 1.244 0.000 0.032 0.000 1.257 1.333 4) 6 H1-3+VT tnxTower Report - version 6.0.4.0 1 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Section Elevation Ratio Ratio Ratio Ratio No. P & fby f It P Fb. Fh F Ratio Comb. Allow. fW Stress Stress Fw Ratio Ratio July 18, 2012 CC/ BU No 878532 Page 19 Criteria Section Capacity Table Section Elevation Component Size Critical P SF'P ill Pass No. ft Type Element K K Capacity Fail L1 159 - 133.42 Pole TP21.29x16x0.1875 1 -3.20 632.62 46.0 Pass L2 133.42 - 87.837 Pole T1330.21x20.26010.25 2 -10.35 1199.42 101.5 Fail L3 87.837 - Pole TP38.8x28.8256x0.3125 3 -17.52 1927.60 103.8 Fail 43.2903 ' L4 43.2903 - 0 Pole TP47x37.0697x0.375 4 -28.76 2885.04 94.3 Pass Summary Pole (1-3) 103.8 Fail RATING = 103.8 Fail X tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 APPENDIX B BASE LEVEL DRAWING July 18, 2012 CC/ BU No 878532 Page 20 tnxTower Report - version 6.0.4.0 g s e 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 APPENDIX C ADDITIONAL CALCULATIONS July 18, 2012 CCI BU No 878532 Page 21 tnxTower Report - version 6.0.4.0 Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces BU#: 878532 TIA Revision:1 F Site Name: F1/MONTICELLO/FULFILLMENT Max. Service Shaft M: 2787.788 ft-kips (* Note) App #: 149920 Rev. 0 Max. Service Shaft P: 29 kips Max Axial Force Type:1 Comp. Note: Max Shaft Superimposed Moment does not necessarily Enter Load Factors Below: equal to the shaft top reaction moment For M (WL) 1.3 <---- Enter Factor For P (DL) 1 1.3 ' <- Enter Factor Pier Properties Concrete: Pier Diameter =1 6.5 Ift Concrete Area = 4778.4 in Reinforcement. Clear Cover to Tie=l 3.00 In Horiz. Tie Bar Size=j Vert. Cage Diameter = 5.78 ft Vert. Cage Diameter = 69.34 in Vertical Bar Size =I 11 Bar Diameter = 1.41 in Bar Area = 1.56 in Number of Bars =I 20 As Total= 31.2 in' A s/ Aconc, Rho: 0.0065 0.65% ACI 10.5 , ACI 21.10.4, and IBC 1810. Min As for Flexural. Tension Controlled. Shafts: 3)*(S q rt(f c)/Fy: 0.0032 200 / Fy: 0.0033 Minimum Rho Check: Actual Req'd Min. Rho:I 0.33% JFIexural Provided Rho:I 0.65% JOK Ref. Shaft Max Axial Capacities. d) Max(Pn or Tn): Max Pu = (T=0.65) Pn. Pn per ACI 318 (10-2) 9366.42 1 kips at Mu=((=0.65)Mn= 5297.94 Ift-kips MaxTu,((p=0.9)Tn=l 1684.8 Ikips at Mu=(=(0.90)Mn= 0.00 Ift-kips Load Factor Shaft Factored Loads 1.30 Mu: 3624.124Ift-kips 1. 30 Pu: 37.7 kips Material Properties Concrete Comp. strength, fc = 4000 psi Reinforcement yield strength, Fy = 60 ksi Reinforcing Modulus of Elasticity, E = 29000 ksi Reinforcement yield strain = 0.00207 Limiting compressive strain = 0.003 ACI 318 Code Select Analysis ACI Code= 1 2002 Seismic Properties Seismic Design Category =I B I Seismic Risk = Low Solve I<-- Press Upon Completing All Input Run) II Results: Governing Orientation Case: 2 Mu Mu I Case 1 Case 2 Dist. From Edge to Neutral Axis: 11.64 in Extreme Steel Strain, et: 0.0159 ct > 0.0050, Tension Controlled Reduction Factor,cp: 0.900 Output Note: Negative Pu=Tension For Axial Compression, cp Pn = Pu: 37.70 kips Drilled Shaft Moment Capacity, cpMn: 4660.48 ft-kips Drilled Shaft Superimposed Mu: 3624.12 ft-kips Mu/ cpMn, Drilled Shaft Flexure CSR: 77.8% Drilled - Shaft -Moment -Capacity, DSMC, Version 1.1 - Effective 04/01/ 2010 Analysis Date: 7/18/2012 Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material I TIA Rev F1 Site Data Reactions BU#:878532 Moment:1 2580 ft-kips Site Name: F1/MONTICELLO/FULFILL Axial:1 29 kips App #: 149920 Rev. 0 Shear l 24 kips Pole Manufacturer: I Other Anchor Rod Data If No stiffeners, Criteria: I AISC ASD I -only Applcable to Unstiffened Cases Qty: 1 12 Diam:1 2.25 in Rod Material:1 A615-J Anchor Rod Results Stiffened Strength (Fu):J 100 ksi Maximum Rod Tension: 181.9 Kips Service, ASD Yield (Fy): 75 ksi Allowable Tension: 195.0 Kips Fty*ASIF Bolt Circle: 56 in Anchor Rod Stress Ratio: 93.3% Pass Plate Data Diam:1 62 in Base Plate Results Flexural Check Stiffened Thick: 1 1.75 in Base Plate Stress: 58.2 ksi Service, ASD Grader 60 ksi Allowable Plate Stress: 60.0 ksi 0.75*Fy*ASIF Single -Rod B-eff:1 12.43 in Base Plate Stress Ratio: 97.0% Pass Y.L. Length: N/A, Roark Stiffener Data (Welding at both sides) Config: 1 3 Weld Type: I Both Groove Depth:! 0.5 in ** Groove Angler 45 degrees Fillet H. Weld: 1 0.1875 in Fillet V. Weld: 0.3125 in Width: 6 in Height: 18 in Thick: 1 in Notch: 1 in Grade: 50 ksi Weld str.: 70 ksi Clear Space between 6 in Stiffeners (b): Pole Data Diam: 47 in Thick: 0.375 in Grade: 65 ksi of Sides: 18 0" IF Round Fu 80 ksi Reinf. Fillet Weld 0 0" if None Stress Increase Factor ASIFJ 1.333 1 Stiffener Results Horizontal Weld : 38.0% Pass Vertical Weld: 38.8% Pass Plate Flex+Shear, fb/Fb+(fv/Fv)^2: 8.3% Pass Plate Tension+Shear, ft/Ft+(fv/Fv)^2: 38.2% Pass Plate Comp. (AISC Bracket): 37.8% Pass Pole Results Pole Punching Shear Check: 8.9% Pass 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5 - Circular Base F 1.2, Effective March 19, 2012 Analysis Date: 7/18/2012 Monopole Drilled Pier Checks capacity of a single drilled shaft foundation for a monopole BU#: 878532 Site Name: F1/MONT/CELLO/FULFILLMENT SY App Number: 149920 Rev. 0 Design Reactions I Shear, S: 24.00 kips Moment, Mt 2580.00 ft-kips Tower Weight, Wt: 29.00 kips Tower Height, H! 159 ft Base Diameter, BD: 47.0 in Foundation Dimensions I Caisson Diameter, CD: 6.5 it Ext. Above Grade, E: 1.0 ft Depth Below Grade, L: 28.0 it Neglected Depth, N: 5.0 it Reber Size, Sp: 11 Reber Quantily, mp: 20 Tie Size, tp: 5 Material Properties Reber Tensile, Fy: 60 ksi Concrete Strength, F'c: 40600 psi Concrete Density, 6x: 150 pcf Clear Cover, cc: 3 in ISoil Properties I Soil Unit Weight, y: 105 Allowable Bearing, Bc: 13.500 pcf ksf Seismic Design Caisson Analysis Depth to Zero Shear: 8.4 it Max Factored Moment: 3624.12 ft-kips Overturning FOS: 4.16 0 CCA TLE I ACI 318 Version:( 2002 Design Checks Capacity/ Demand/ Availability Limits Check Minimum Req'd Dia. 1(it): 6.50 1.65 OK Minimum Req'd Dia. 2 (it): 6.50 5.42 OK Bearing (ksl): 13.50 0.87 OK Rebar Area (in'): 31.20 0.00 OK Pier moment capacity(k-ft): 4660.48 3624.12 OK Reber spacing (in): 9.90 2 < Bs <18 OK Development Length (in): 232.78 12.00 OK Soil moment capacity (FOS): 4.16 2.00 OK IDepth I IShear I IMoment I I 2.9 ft 1 24.2 kips 2656 ft-kips 5.8 ft 24.2 kips 2726.1 ft-kips 8.7 it -3.3 kips 2761.7 ft-kips r Assume 0.33% Minimum Steel? Bearing: 6.5% Steel: 77.8% Soll: 48.1% Monopole Drilled Pier (Caisson) Version 1.5 Effective Date: 04/26/2012 878532_Caisson.txt CAISSON version 10.40 10:47:16 AM Wednesday, July 18, 2012 Crown Castle USA A*A*#*AR4A*******t*********##4*Ad4k44dA*R*R###*A*A*##b#**4#d*t**R44#44A*4*#44**t**AR*******#*d*dA4 4 * CAISSON - Pier Foundations Analysis and Design - Copyright Power Line Systems, Inc. 1993-2010 ' A * AAA*****A*d*#**#d**##tr4*4*d44#4*4444#444R444*4##*4A4A#Rt*AAA#444*4*4**AAAARAA*A*A********bARAR*fR* Project Title: BUM 878532 Project Notes: Calculation Method: Full BCD I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength ft) (ft) (ksi) (ksi) 6.50 1.00 4.00 60.00 Soil Properties Layer Type Thickness Depth at Top Density CU KP PHI of Layer ft) (ft) (lbs/ftA3) (psf) (deg) 1 Clay 5.00 0.00 105.0 2 Sand 23.00 5.00 105.0 3.255 32.00 Design (Factored) Loads at Top of Pier Moment Axial Shear Additional Safety Load Load Factor Against Soil Failure ft-k) kips) kips) 2580.0 29.0 24.00 4.16 4*R*** R E S U L T S Calculated Pier Properties Length weight End Bearing Pressure ft) kips) psf) 29.000 144.346 873.9 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density to Top Of Pier ft) ft) lbs/ftA3) Clay 1.00 5.00 105.0 Sand 6.00 15.48 105.0 Sand 21.48 7.52 105.0 Shear and Moments Along Pier Distance below Shear Moment Top of Pier with Safety Factor) with Safety Factor) ft) kips) ft-k) 0.00 100.5 10757.4 2.90 100.5 11049.0 5.80 100.5 11340.6 8.70 13.7 11488.8 11.60 190.6 11206.1 14.50 423.5 10329.3 17.40 712.4 8695.8 20.30 1057.4 6143.2 23.20 970.2 2922.0 26.10 513.1 757.6 29.00 0.0 0.0 CU KP Force Arm psf) (kips) (ft) 0.00 3.50 3.255 1314.88 15.31 3.255-1214.34 25.44 Shear Moment without Safety Factor) (without Safety Factor) kips) (ft-k) 24.2 2585.9 24.2 2656.0 24.2 2726.1 3.3 2761.7 45.8 2693.8 101.8 2483.0 171.3 2090.3 254.2 1476.7 233.2 702.4 123.4 182.1 0.0 0.0 Page 1 V CADate: July 18, 2012 T" Branden Woodard Crown Castle Crown Castle 2000 Corporate Drive 2000 Corporate Drive Canonsburg, PA 15317 Canonsburg, PA 15317 (724) 416-2000 Subject: Structural Analysis Report Carrier Designation: Sprint PCS Co -Locate Carrier Site Number. MS57XC757 Carrier Site Name: N/A Crown Castle Designation: Crown Castle BU Number: 878532 Crown Castle Site Name: F1/MONTICELLO/FULFILLMENT SYST Crown Castle JDE Job Number, 175816 Crown Castle Work Order Number: 511647 Crown Castle Application Number: 149920 Rev. 0 Engineering Firm Designation: Crown Castle Project Number: 511647 I Site Data: 406 EAST 7TH STREET, MONTICELLO, Wright County, MN Latitude 45° 17' 53.22", Longitude -93° 47` 32.84" 159 Foot - Monopole Tower Dear Branden Woodard, Crown Castle is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural Statement of Work' and the terms of Crown Castle Purchase Order Number 511647, in accordance with application 149920, revision 0. The purpose of the analysis Is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Sufficient Capacity Note: See Table I and Table II for the proposed and existing loading, respectively. The analysis has been performed in accordance with the TIA/EIA-222-F standard and local code requirements based upon a wind speed of 80 mph fastest mile. All modifications and equipment proposed In this report shall be (installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at Crown Castle appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Structural analysis prepared by: Calvin Straub, E.I.T. / M.B Respectfully submitted by: SeNAB . Z'9 y ' j•• UCENSED PROFESSIONAL Reza Jenabzadeh, P.E. ENGINEER e Engineer II 49357 : AZ Z' Ci tnxTower Report - version 6.0.4.0 OF M10 %,% PROFESSIONALINGINEER I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Ucensed Professional Engineer under the law of the State of Minnesota. Print Name: Re;a Jen Ozioeh 1 P Signature: /e 3 Date:-Y /O7— Ucense ii-M7 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 — Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations July 18, 2012 CCI BU No 878532 Page 2 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 1) INTRODUCTION July 18, 2012 CCI BU No 878532 Page 3 This tower is a 159 ft Monopole tower designed by ENGINEERED ENDEAVORS, INC. in April of 2003. The tower was originally designed for a wind speed of 85 mph per TIA/EIA-222-F. The tower has been modified per reinforcement drawings prepared by GPD Associates, Inc, in April of 2008. Reinforcement consists of addition of base plate stiffeners. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA/EIA-222-F Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a fastest mile wind speed of 80 mph with no ice, 37.1 mph with 0.75 inch ice thickness and 50 mph under service loads. Table 1, - Proposed Antenna and Cable Information Center Number Mounting Line of Antenna Antenna ModelLevel (ft) Elevation Antennas Manufacturer ft) 1 powerwave P65-16-XLPP-RR w/ technologies Mount Pipe 2 powerwave P90-15-XLPP-RR w/ technologies Mount Pipe 155.0 157.0 3 samsungtelecommunications RRH-C2A w/EXT FILTER 3 samsung RRH-P4 telecommunications Table 2 - Existing Antenna and Cable Information Center Number Mounting Line of Antenna Antenna Model Level (ft) Elevation Antennas Manufacturer ft) 157.0 6 ems wireless FV65-14-OPN w/ Mount 155.0 e2p 155.0 1 tower mounts T-Arm Mount [TA 601-3] 142.0 9 andrew TMBX-6517-R2M w/ Mount Pipe 140.0 6 andrew ETT19V2S12UB 140.0 1 tower mounts Platform Mount [LP 303-1] 123.0 6 powerwave RA21.7770.00 w/ Mount technologies Pipe 120.0 12 andrew 641280-DF 120.0 1 tower mounts Platform Mount [LP 701-1] Notes: 1) Existing Equipment 2) Equipment to be Removed Number Feed of Feed Line Note Lines Size (in) Number Feed of Feed Line Note Lines Size (in) 6 1-5/8 2 1 18 1-5/8 1 12 1-5/8 1 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 4 Table 3 - Design Antenna and Cable Information Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size (in) ft) 160 160 12 dapa 48000 - - 140 140 12 dapa 48000 - - 120 120 12 dapa 48000 - - 100 100 12 dapa 48000 - - 80 80 12 dapa 48000 - - 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document Remarks Reference Source 4-GEOTECHNICAL REPORTS Terracon 1504987 CCISITES 4-POST-MODIFICATION GPD Associates, Inc. 2286749 CCISITES INSPECTION 4-TOWER FOUNDATION Engineered Endeavors, Inc. 1621567 CCISITES DRAWINGS/DESIGN/SPECS 4-TOWER MANUFACTURER Engineered Endeavors, Inc. 1617475 CCISITES DRAWINGS 4-TOWER REINFORCEMENT GPD Associates, Inc. 2231372 CCISITES DESIGN/DRAWINGS/DATA 3.1) Analysis Method tnxTower (version 6.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) When applicable, transmission cables are considered as structural components for calculating wind loads as allowed by TIA/EIA-222-F. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 July 18, 2012 CCI BU No 878532 Page 5 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Section I Elevation (ft) Component Size Critical P (K) SF*P_allowl I Pass 1 Fail No. Type Element K) Capacity L1 ' 159 - 133.42 Pole TP21.29x16x0.1875 1 3.23 632.62 29.8 I Pass L2 133.42- Pole TP30.21x20.2601x0.25 2 87.837 10.09 1199.42 81.8 Pass L3 87.837 Pole TP38.8x28.8256x0.3125 3 16.84 1927.60 87.7 Pass 43.2903 L4 l 43.2903 - 0 Pole TP47x37.0697x0.375 4 27.65 2885.04 I 82.0 I Pass ISummaryl I Pole (1-3) I 87.7 l Pass Rating = I 87.7 I Pass Table 6 - Tower Component Stresses vs. Capacity Notes Component I Elevation (ft) I Capacity I Pass / Fail 1 Anchor Rods 0 80.9 Pass 1 Base Plate 0 84.4 Pass l 1 I Base Foundation I 0 I 67.9 I Pass Structure Rating (max from all components) = I 87.7% Notes: 1) See additional documentation in "Appendix C — Additional Calculations" for calculations supporting the % capacity consumed. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing and proposed loads. No modifications are required at this time. tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 APPENDIX A TNXTOWER OUTPUT July 18, 2012 CCI BU No 878532 Page 6 tnxTower Report - version 6.0.4.0 133...4it. pp QG c1NVODNa G N N N 0 0 0 N m N m 16 O N M 43.31t 0.0 it 8 o m w 5 E1ig' E2 F t S c5 3 DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION P90-15-XLPP-RR w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 140 P65.16-XLPP-RR w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 140 P90.15-XLPP-RR w/ Mount Pipe 155 3) TMBX-6517-R2M w/ Mount Pipe 140 RRH-C2A w/EXT FILTER 155 Platform Mount (LP 303.11 140 1 RRH-C2A w/EXT FILTER 155 2) RA21.7770.00 w/ Mount Pipe 120 1 RRH-C2A w/EXT FILTER 155 2) RA21.7770.00 w/ Mount Pipe 120 1 RRH-P4 155 2) RA21.7770.00 w/ Mount Pipe 120 RRH-P4 1155 4) 6412WDF 120 l 1 RRH-P4 1155 4) 6412WDF 120 1 T-Arm Mount [TA 601.31 1155 4) 6412WDF 120 1 Vx2' Antenna Mount Pipe 1155 Platform Mount (LP 701-11 120 1 8'x2' Antenna Mount Pipe 1155 2) Tx2' Antenna Mount Pipe 0 18'x2' Antenna Mount Pipe 1155 2) Txr Antenna Mount Pipe 0 1(2) ETT19V2S12UB 1 140 2) Tx2' Antenna Mount Pipe 0 1(2) ET rl9V2Sl2UB 1 140 4) Tx2 Antenna Mount Pipe 0 1 1(2) ETT19V2S12UB 1140 MATERIAL STRENGTH I GRADE I65ksl FV I80ksi Fu I GRADE i FV 1 Fu A572-65 TOWER DESIGN NOTES 1. Tower is located in Wright County, Minnesota. 2. Tower designed for a 80 mph basic wind in accordance with the TIA/EIA-222-F Standard. 3. Tower is also designed for a 37 mph basic wind with 0.75 in ice. Ice is considered to increase in thickness with height. 4. Deflections are based upon a 50 mph wind. 5. TOWER RATING: 87.7% AXIAL 47 KK SHEAR \ MOMENT 6 K i 666 kip-ft TORQUE 0 kip-ft 37 mph WIND - 0.7500 in ICE AXIAL 28 K SHEA MOMENT 22 K ` 2241 kip -It TORQUE 1 kip-ft REACTIONS - 80 mph WIND I,l Crown Castle Job:BU# 878532 R rN 2000 Corporate Drive Project: u i CAS LE Canonsburg PA 15317 "1anl• Crown Castle IDrawnby:CStraub Aid We Are solutions Phone: (724) 416-2000 fie' TIA/EIA-222-F Date'07/18/12 Iscaje: NTS FAX: (724) 416-2254 Path: A wn. a •,Gap z R M .. Dwg No. E-1 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision t7 Tower Input Data July 18, 2012 CCI BU No 878532 Page -7 There is a pole section. This tower is designed using the TIA/EIA-222-F standard. The following design criteria apply: 3) Tower is located in Wright County, Minnesota. 4) Basic wind speed of 80 mph. 5) Nominal ice thickness of 0.7500 in. 6) Ice thickness is considered to increase with height. 7) Ice density of 56 pcf. 8) A wind speed of 37 mph is used in combination with ice. 9) Temperature drop of 50 OF. 10) Deflections calculated using a wind speed of 50 mph. 11) A non -linear (P-delta) analysis was used. 12) Pressures are calculated at each section. 13) Stress ratio used in pole design is 1.333. 14) Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification 4 Use Code Stress Ratios 4 Use Code Safety Factors - Guys 4 Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Options Distribute Leg Loads As Uniform Assume Legs Pinned 4 Assume Rigid Index Plate 4 Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension 4 Bypass Mast Stability Checks 4 Use Azimuth Dish Coefficients 4 Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feedline Bundles As Cylinder Use ASCE 10 X-Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation 4 Consider Feedline Torque Include Angle Block.Shear Check_. Poles 1 Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 159.00-133.42 25.58 3.17 18 16.0000 21.2900 0.1875 0.7500 A572-65 65 ksi) L2 133.42-87.84 48.75 4.33 18 20.2601 30.2100 0.2500 1.0000 A572-65 65 ksi) L3 87.84-43.29 48.88 5.42 18 28.8256 38.8000 0.3125 1.2500 A572-65 65 ksi) L4 43.29-0.00 48.71 18 37.0697 47.0000 0.3750 1.5000 A572-65 65 ksi) Tapered Pole Properties Section Tip Dia. Area I r , C in in2 in4 in in L1 16.2468 9.4104 297.2674 5.6134 8.1280 l/C J AIQ w w/t in3 in4 inz in 36.5733 594.9259 4.7061 2.4860 13.259 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 8 Section Tip Dia. Area 1 r C VC J IYQ w w/t in in2 in4 in in 0 in° in2 in 21.6184 12.5586 706.5573 7.4914 10.8153 65.3293 1414.0443 6.2805 3.4170 18.224 L2 21.2290 15.8780 803.2105 7.1036 10.2921 78.0414 1607.4779 7.9405 3.1258 12.503 30.6760 23.7733 2695.9374 10.6358 15.3467 175.6691 5395.4222 11.8889 4.8770 19.508 L3 30.1681 28.2814 2904.8668 10.1221 14.6434 198.3740 5813.5559 14.1434 4.5233 14.475 39.3986 38.1748 7144.1983 13.6631 19.7104 362.4583 14297.797 19.0910 6.2788 20.092 1 L4 38.7629 43.6758 7429.9282 13.0266 18.8314 394.5501 14869.632 21.8421 5.8643 15.638 8 47.7251 55.4954 15241.656 16.5519 23.8760 638.3673 30503.368 27.7530 7.6120 20.299 7 7 Tower Gusset Gusset Gusset GradeAdjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt per face) Ar Spacing Spacing Diagonals Horizontals ft ft2 in in in L1 159.00- 1 1 1 133.42 L2 133.42- 1 1 1 87.84 L3 87.84- 1 1 1 43.29 L4 43.29-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft ft2/ft off TYPE 5( 1 1/4") C No CaAa (Out Of 155.00 - 0.00 3 No Ice 0.00 1.10 Face) 1/2" Ice 0.00 2.18 1" Ice 0.00 3.86 2" Ice 0.00 9.07 4" Ice 0.00 26.81 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 3 No Ice 0.20 0.70 Face) 1/2" Ice 0.30 2.23 1" Ice 0.40 4.38 2" Ice 0.60 10.50 4" Ice 1.00 30.07 AVA7-50(1-5/8) C No CaAa (Out Of 140.00 - 0.00 15 No Ice 0.00 0.70 Face) 1/2" Ice 0.00 2.23 1" Ice 0.00 4.38 2" Ice 0.00 10.50 4" Ice 0.00 30.07 LDF7-50A(1-5/8") C No Inside Pole 120.00 - 0.00 12 No Ice 0.00 0.82 1/2" Ice 0.00 0.82 1" Ice 0.00 0.82 2" Ice 0.00 0.82 4" Ice 0.00 0.82 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft2 K L1 159.00-133.42 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 3.968 0.15 L2 133.42-87.84 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 27.487 1.04 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Tower Tower Face AR AF Sectio Elevation n It ft2 It, L3 87.84-43.29 A 0.000 0.000 B 0.000 0.000 C 0.000 0.000 L4 43.29-0.00 A 0.000 0.000 B 0.000 0.000 C 0.000 0.000 CAAA CAAA Weight In Face Out Face It, ft2 K 0.000 0.000 0.00 0.000 0.000 0.00 0.000 26.862 1.15 0.000 0.000 0.00 0.000 0.000 0.00 0.000 26.104 1.11 July 18, 2012 CCI BU No 878532 Page 9 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n It Leg in ft2 ft2 fie ft2 K L1 159.00-133.42 A 0.896 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 7.506 0.69 L2 133.42-87.84 A 0.866 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 51.999 4.02 L3 87.84-43.29 A 0.814 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 50.013 3.94 L4 43.29-0.00 A 0.750 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 47.241 3.63 Feed Line Center of Pressure Section Elevation CPX CPZ CPX CPZ Ice Ice It in in in in L1 159.00-133.42 0.2025 0.1169 0.3279 0.1893 L2 133.42-87.84 0.6105 0.3525 0.9229 0.5328 L3 87.84-43.29 0.6467 0.3734 1.0101 0.5832 L4 43.29-0.00 0.6696 0.3866 1.0534 0.6082 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert It ft ft2 ft2 It It P90-15-XLPP-RR w/ A From Leg 4.00 0.0000 155.00 No Ice 8.64 6.36 0.07 Mount Pipe 0.00 1/2" 9.29 7.54 0.13 2.00 Ice 9.91 8.43 0.21 1" Ice 11.18 10.24 0.38 2" Ice 13.83 14.10 0.88 4" Ice P65-16-XLPP-RR w/ B From Leg 4.00 0.0000 155.00 No Ice 8.64 6.36 0.07 Mount Pipe 0.00 1/2" 9.29 7.54 0.14 2.00 Ice 9.91 8.43 0.21 1" Ice 11.18 10.24 0.39 2" Ice 13.83 14.10 0.88 4" Ice P90-15-XLPP-RR w/ C From Leg 4.00 0.0000 155.00 No Ice 8.64 6.36 0.07 Mount Pipe 0.00 1/2" 9.29 7.54 0.13 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft, ft2 K ft ft 2.00 Ice 9.91 8.43 0.21 1" Ice 11.18 10.24 0.38 2" Ice 13.83 14.10 0.88 4" Ice RRH-C2A WEXT FILTER A From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-C2A WEXT FILTER B From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-C2A WEXT FILTER C From Leg 4.00 0.0000 155.00 No Ice 3.63 1.55 0.06 0.00 1/2" 3.89 1.75 0.08 2.00 Ice 4.16 1.96 0.10 1" Ice 4.72 2.41 0.16 2" Ice 5.95 3.40 0.33 4" Ice RRH-P4 A From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice RRH-P4 B From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice RRH-P4 C From Leg 4.00 0.0000 155.00 No Ice 3.19 2.07 0.06 0.00 1/2" 3.44 2.29 0.08 2.00 Ice 3.70 2.52 0.11 1" Ice 4.24 2.99 0.17 2" Ice 5.42 4.05 0.35 4" Ice T-Arm Mount [TA 601-3] C None 0.0000 155.00 No Ice 10.90 10.90 0.73 1/2" 14.65 14.65 0.93 Ice 18.40 18.40 1.13 1" Ice 25.90 25.90 1.52 2" Ice 40.90 40.90 2.32 4" Ice 8'x2" Antenna Mount Pipe A From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.03 0.00 1/2" 2.73 2.73 0.04 0.00 Ice 3.40 3.40 0.06 1" Ice 4.40 4.40 0.12 2" Ice 6.50 6.50 0.30 4" Ice 8'x2" Antenna Mount Pipe B From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.03 0.00 1/2" 2.73 2.73 0.04 0.00 Ice 3.40 3.40 0.06 1" Ice 4.40 4.40 0.12 2" Ice 6.50 6.50 0.30 4" Ice 8'x2" Antenna Mount Pipe C From Leg 4.00 0.0000 155.00 No Ice 1.90 1.90 0.03 0.00 1/2" 2.73 2.73 0.04 0.00 Ice 3.40 3.40 0.06 1" Ice 4.40 4.40 0.12 2" Ice 6.50 6.50 0.30 4" Ice tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 11 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert It it fe fe K ft ft 2) ETT19V2S12UB A From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.01 0.00 1/2" 0.78 0.41 0.02 0.00 Ice 0.90 0.50 0.02 1" Ice 1.17 0.72 0.04 2" Ice 1.81 1.27 0.10 4" Ice 2) ETT19V2S12UB B From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.01 0.00 1/2" 0.78 0.41 0.02 0.00 Ice 0.90 0.50 0.02 1" Ice 1.17 0.72 0.04 2" Ice 1.81 1.27 0.10 4" Ice 2) ETT19V2S12UB C From Leg 4.00 0.0000 140.00 No Ice 0.67 0.32 0.01 0.00 1/2" 0.78 0.41 0.02 0.00 Ice 0.90 0.50 0.02 1" Ice 1.17 0.72 0.04 2" Ice 1.81 1.27 0.10 4" Ice 3) TMBX-6517-R2M w/ A From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 0.04 Mount Pipe 0.00 1/2" 6.88 7.00 0.09 2.00 Ice 7.48 8.15 0.15 1" Ice 8.67 10.16 0.30 2" Ice 11.14 14.39 0.75 4" Ice 3) TMBX-6517-R2M w/ B From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 0.04 Mount Pipe 0.00 1/2" 6.88 7.00 0.09 2.00 Ice 7.48 8.15 0.15 1" Ice 8.67 10.16 0.30 2" Ice 11.14 14.39 0.75 4" Ice 3) TMBX-6517-R2M w/ C From Leg 4.00 0.0000 140.00 No Ice 6.26 5.68 0.04 Mount Pipe 0.00 1/2" 6.88 7.00 0.09 2.00 Ice 7.48 8.15 0.15 1" Ice 8.67 10.16 0.30 2" Ice 11.14 14.39 0.75 4" Ice Platform Mount [LP 303-1] C None 0.0000 140.00 No Ice 14.66 14.66 1.25 1/2" 18.87 18.87 1.48 Ice 23.08 23.08 1.71 1" Ice 31.50 31.50 2.18 2" Ice 48.34 48.34 3.10 4" Ice 2) RA21.7770.00 w/ A From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ B From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 2) RA21.7770.00 w/ C From Leg 4.00 0.0000 120.00 No Ice 7.03 5.00 0.06 Mount Pipe 0.00 1/2" 7.61 5.96 0.11 3.00 Ice 8.16 6.75 0.17 1" Ice 9.31 8.37 0.32 2" Ice 11.72 11.87 0.75 4" Ice 4) 641280-DF A From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CC/ BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Norz Adjustmen Front Side Leg Lateral t Vert ft ft ftz ft2 K ft ft 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF B From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice 4) 641280-DF C From Leg 4.00 0.0000 120.00 No Ice 0.14 0.18 0.00 0.00 1/2" 0.20 0.26 0.01 0.00 Ice 0.28 0.35 0.01 1" Ice 0.45 0.55 0.03 2" Ice 0.90 1.06 0.09 4" Ice Platform Mount [LP 701-1] C None 0.0000 120.00 No Ice 59.15 59.15 2.75 1/2" 71.12 71.12 3.42 Ice 83.09 83.09 4.10 1" Ice 107.03 107.03 5.45 2" Ice 154.91 154.91 8.15 4" Ice 2) 7'x2" Antenna Mount A From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) 7'x2" Antenna Mount B From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 2) 7'x2" Antenna Mount C From Leg 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice 4) 7'x2" Antenna Mount C From Face 0.00 0.0000 0.00 No Ice 1.66 1.66 0.03 Pipe 0.00 1/2" 2.39 2.39 0.04 0.00 Ice 2.83 2.83 0.06 1" Ice 3.71 3.71 0.10 2" Ice 5.58 5.58 0.27 4" Ice Comb. No. 1 Dead Only 2 Dead+Wind 0 deg - No Ice 3 Dead+Wind 30 deg - No Ice 4 Dead+Wind 60 deg - No Ice 5 Dead+Wind 90 deg - No Ice 6 Dead+Wind 120 deg - No Ice 7 Dead+Wind 150 deg - No Ice 8 Dead+Wind 180 deg - No Ice 9 Dead+Wind 210 deg - No Ice tnxTower Report - version 6.0.4.0 Load Combinations Description 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 July 18, 2012 CC/ BU No 878532 Page 13 Comb. Description No. 10 Dead+Wind 240 deg - No Ice 11 Dead+Wind 270 deg - No Ice 12 Dead+Wind 300 deg - No Ice 13 Dead+Wind 330 deg - No Ice 14 Dead+Ice+Temp 15 Dead+Wind 0 deg+Ice+Temp 16 Dead+Wind 30 deg+Ice+Temp 17 Dead+Wind 60 deg+Ice+Temp 18 Dead+Wind 90 deg+Ice+Temp 19 Dead+Wind 120 deg+Ice+Temp 20 Dead+Wind 150 deg+Ice+Temp 21 Dead+Wind 180 deg+Ice+Temp 22 Dead+Wind 210 deg+Ice+Temp 23 Dead+Wind 240 deg+Ice+Temp 24 Dead+Wind 270 deg+Ice+Temp 25 Dead+Wind 300 deg+Ice+Temp 26 Dead+Wind 330 deg+Ice+Temp 27 Dead+Wind 0 deg - Service 28 Dead+Wind 30 deg - Service 29 Dead+Wind 60 deg - Service 30 Dead+Wind 90 deg - Service 31 Dead+Wind 120 deg - Service 32 Dead+Wind 150 deg - Service 33 Dead+Wind 180 deg - Service 34 Dead+Wind 210 deg - Service 35 Dead+Wind 240 deg - Service 36 Dead+Wind 270 deg - Service 37 Dead+Wind 300 deg - Service 38 Dead+Wind 330 deg - Service Maximum Member Forces Sectio Elevation Component Condition Gov. Force Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 159 - 133.42 Pole Max Tension 5 0.00 0.00 0.00 Max. Compression 14 7.41 0.48 0.31 Max. Mx 11 3.23 77.79 0.06 Max. My 8 3.23 0.10 77.75 Max. Vy 11 6.87 77.79 0.06 Max. Vx 8 6.87 0.10 77.75 Max. Torque 13 0.02 L2 133.42 - Pole Max Tension 1 0.00 0.00 0.00 87.837 Max. Compression 14 20.57 4.07 2.38 Max. Mx 11 10.09 579.42 0.44 Max. My 8 10.09 0.76 579.10 Max. Vy 11 14.52 579.42 0.44 Max. Vx 8 14.52 0.76 579.10 Max. Torque 13 0.21 L3 87.837 - Pole Max Tension 1 0.00 0.00 0.00 43.2903 Max. Compression 14 31.25 8.62 5.01 Max. Mx 11 16.84 1285.80 0.95 Max. My 8 16.84 1.64 1285.11 Max. Vy 11 17.89 1285.80 0.95 Max. Vx 8 17.89 1.64 1285.11 Max. Torque 13 0.43 L4 43.2903 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 14 46.89 14.26 8.64 Max. Mx 11 27.95 2240.35 1.87 Max. My 8 27.95 2.82 2239.39 Max. Vy 11 21.68 2240.35 1.87 Max. Vx 8 21.68 2.82 2239.39 Max. Torque 6 0.90 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 14 Maximum Reactions Location Condition Gov. Vertical Horizontal, X Horizontal, Z Load K K K Comb. Pole Max. Vert 23 46.89 5.19 3.00 Max. H. 11 27.96 21.66 0.00 Max. Hz 2 27.96 0.00 21.66 Max. Mx 2 2235.67 0.00 21.66 Max. M, 5 2234.71 21.66 0.00 Max. Torsion 12 0.90 18.76 10.83 Min. Vert 1 27.96 0.00 0.00 Min. Hx 5 27.96 21.66 0.00 Min. H= 8 27.96 0.00 21.66 Min. Mx 8 2239.39 0.00 21.66 Min. M. 11 2240.35 21.66 0.00 Min. Torsion 6 0.90 18.76 10.83 Tower Mast Reaction Summary Load Vertical Shear, Shear= Overturning Overturning Torque Combination Moment, Mx Moment, M, K K K kip-ft kip-ft kip-ft Dead Only 27.96 0.00 0.00 1.84 2.78 0.00 Dead+Wind 0 deg - No Ice 27.96 0.00 21.66 2235.67 2.82 0.59 Dead+Wind 30 deg - No Ice 27.96 10.83 18.76 1935.91 1115.95 0.16 Dead+Wind 60 deg - No Ice 27.96 18.76 10.83 1116.91 1934.95 0.31 Dead+Wind 90 deg - No Ice 27.96 21.66 0.00 1.87 2234.71 0.70 Dead+Wind 120 deg - No Ice 27.96 18.76 10.83 1120.64 1934.95 0.90 Dead+Wind 150 deg - No Ice 27.96 10.83 18.76 1939.63 1115.95 0.86 Dead+Wind 180 deg - No Ice 27.96 0.00 21.66 2239.39 2.82 0.59 Dead+Wind 210 deg - No Ice 27.96 10.83 18.76 1939.63 1121.59 0.16 Dead+Wind 240 deg - No Ice 27.96 18.76 10.83 1120.63 1940.58 0.31 Dead+Wind 270 deg - No Ice 27.96 21.66 0.00 1.87 2240.35 0.70 Dead+Wind 300 deg - No Ice 27.96 18.76 10.83 1116.90 1940.59 0.90 Dead+Wind 330 deg - No Ice 27.96 10.83 18.76 1935.90 1121.60 0.86 Dead+Ice+Temp 46.89 0.00 0.00 8.64 14.26 0.00 Dead+Wind 0 46.89 0.00 6.00 641.10 14.30 0.25 deg+Ice+Temp Dead+Wind 30 46.89 3.00 5.19 554.05 310.58 0.08 deg+Ice+Temp Dead+Wind 60 46.89 5.19 3.00 316.22 548.41 0.10 deg+Ice+Temp Dead+Wind 90 46.89 6.00 0.00 8.66 635.46 0.26 deg+Ice+Temp Dead+Wind 120 46.89 5.19 3.00 333.54 548.41 0.35 deg+Ice+Temp Dead+Wind 150 46.89 3.00 5.19 571.36 310.58 0.35 deg+Ice+Temp Dead+Wind 180 46.89 0.00 6.00 658.41 14.30 0.25 deg+Ice+Temp Dead+Wind 210 46.89 3.00 5.19 571.36 339.17 0.08 deg+Ice+Temp Dead+Wind 240 46.89 5.19 3.00 333.53 576.99 0.10 deg+Ice+Temp Dead+Wind 270 46.89 6.00 0.00 8.66 664.05 0.26 deg+Ice+Temp Dead+Wind 300 46.89 5.19 3.00 316.22 577.00 0.35 deg+Ice+Temp Dead+Wind 330 46.89 3.00 5.19 554.05 339.17 0.35 deg+Ice+Temp Dead+Wind 0 deg - Service 27.96 0.00 8.46 873.67 2.83 0.23 Dead+Wind 30 deg - Service 27.96 4.23 7.33 756.38 434.94 0.06 Dead+Wind 60 deg - Service 27.96 7.33 4.23 435.90 755.41 0.12 Dead+Wind 90 deg - Service 27.96 8.46 0.00 1.87 872.71 0.27 Dead+Wind 120 deg - 27.96 7.33 4.23 439.64 755.41 0.35 tnxTower Report - version 6.0.4.0 July 18, 2012 159 Ft Monopole Tower Structural Analysis CCI BU No 878532 Project Number 511647, Application 149920, Revision 0 Page 15 Load Vertical Shear., Shear, Overturning Overturning Torque Combination Moment, M. Moment, M. K K K kip-ft kip-ft kip-ft Service Dead+Wind 150 deg - 27.96 4.23 7.33 760.11 434.94 0.34 Service Dead+Wind 180 deg - 27.96 0.00 8.46 877.41 2.83 0.23 Service Dead+Wind 210 deg - 27.96 4.23 7.33 760.11 440.60 0.06 Service Dead+Wind 240 deg - 27.96 7.33 4.23 439.64 761.08 0.12 Service Dead+Wind 270 deg - 27.96 8.46 0.00 1.87 878.37 0.27 Service Dead+Wind 300 deg - 27.96 7.33 4.23 435.90 761.08 0.35 Service Dead+Wind 330 deg - 27.96 4.23 7.33 756.37 440.61 0.34 Service Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ Error Comb. K K K K K K 1 0.00 27.96 0.00 0.00 27.96 0.00 0.000% 2 0.00 27.96 21.66 0.00 27.96 21.66 0.000% 3 10.83 27.96 18.76 10.83 27.96 18.76 0.000% 4 18.76 27.96 10.83 18.76 27.96 10.83 0.000% 5 21.66 27.96 0.00 21.66 27.96 0.00 0.000% 6 18.76 27.96 10.83 18.76 27.96 10.83 0.000% 7 10.83 27.96 18.76 10.83 27.96 18.76 0.000% 8 0.00 27.96 21.66 0.00 27.96 21.66 0.000% 9 10.83 27.96 18.76 10.83 27.96 18.76 0.000% 10 18.76 27.96 10.83 18.76 27.96 10.83 0.000% 11 21.66 27.96 0.00 21.66 27.96 0.00 0.000% 12 18.76 27.96 10.83 18.76 27.96 10.83 0.000% 13 10.83 27.96 18.76 10.83 27.96 18.76 0.000% 14 0.00 46.89 0.00 0.00 46.89 0.00 0.000% 15 0.00 46.89 6.00 0.00 46.89 6.00 0.000% 16 3.00 46.89 5.19 3.00 46.89 5.19 0.000% 17 5.19 46.89 3.00 5.19 46.89 3.00 0.000% 18 6.00 46.89 0.00 6.00 46.89 0.00 0.000% 19 5.19 46.89 3.00 5.19 46.89 3.00 0.000% 20 3.00 46.89 5.19 3.00 46.89 5.19 0.000% 21 0.00 46.89 6.00 0.00 46.89 6.00 0.000% 22 3.00 46.89 5.19 3.00 46.89 5.19 0.000% 23 5.19 46.89 3.00 5.19 46.89 3.00 0.000% 24 6.00 46.89 0.00 6.00 46.89 0.00 0.000% 25 5.19 46.89 3.00 5.19 46.89 3.00 0.000% 26 3.00 46.89 5.19 3.00 46.89 5.19 0.000% 27 0.00 27.96 8.46 0.00 27.96 8.46 0.000% 28 4.23 27.96 7.33 4.23 27.96 7.33 0.000% 29 7.33 27.96 4.23 7.33 27.96 4.23 0.000% 30 8.46 27.96 0.00 8.46 27.96 0.00 0.000% 31 7.33 27.96 4.23 7.33 27.96 4.23 0.000% 32 4.23 27.96 7.33 4.23 27.96 7.33 0.000% 33 0.00 27.96 8.46 0.00 27.96 8.46 0.000% 34 4.23 27.96 7.33 4.23 27.96 7.33 0.000% 35 7.33 27.96 4.23 7.33 27.96 4.23 0.000% 36 8.46 27.96 0.00 8.46 27.96 0.00 0.000% 37 7.33 27.96 4.23 7.33 27.96 4.23 0.000% 38 4.23 27.96 7.33 4.23 27.96 7.33 0.000% Non -Linear Convergence Results tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00089722 3 Yes 6 0.00000001 0.00009879 4 Yes 6 0.00000001 0.00009916 5 Yes 4 0.00000001 0.00078760 6 Yes 6 0.00000001 0.00009998 7 Yes 6 0.00000001 0.00009861 8 Yes 4 0.00000001 0.00089878 9 Yes 6 0.00000001 0.00010003 10 Yes 6 0.00000001 0.00009966 11 Yes 4 0.00000001 0.00079011 12 Yes 6 0.00000001 0.00009884 13 Yes 6 0.00000001 0.00010022 14 Yes 4 0.00000001 0.00008512 15 Yes 5 0.00000001 0.00032844 16 Yes 5 0.00000001 0.00058409 17 Yes 5 0.00000001 0.00058846 18 Yes 5 0.00000001 0.00032385 19 Yes 5 0.00000001 0.00061960 20 Yes 5 0.00000001 0.00060298 21 Yes 5 0.00000001 0.00033717 22 Yes 5 0.00000001 0.00065948 23 Yes 5 0.00000001 0.00065484 24 Yes 5 0.00000001 0.00033873 25 Yes 5 0.00000001 0.00062146 26 Yes 5 0.00000001 0.00063832 27 Yes 4 0.00000001 0.00022679 28 Yes 5 0.00000001 0.00023056 29 Yes 5 0.00000001 0.00023211 30 Yes 4 0.00000001 0.00020463 31 Yes 5 0.00000001 0.00023674 32 Yes 5 0.00000001 0.00023091 33 Yes 4 0.00000001 0.00022825 34 Yes 5 0.00000001 0.00023893 35 Yes 5 0.00000001 0.00023736 36 Yes 4 0.00000001 0.00020706 37 Yes 5 0.00000001 0.00023273 38 Yes 5 0.00000001 0.00023858 July 18, 2012 CCI BU No 878532 Page 16 Maximum Tower Deflections - Service Wind I Section Elevation Horz. Gov. Tilt Twist No. Deflection Load It in Comb. L1 159 - 133.42 50.081 35 2.7685 0.0012 L2 136.587 - 87.837 37.282 35 2.6364 0.0011 L3 92.1703 - 16.217 35 1.7602 0.0008 43.2903 L4 48.707 - 0 4.296 35 0.8228 0.0003 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature It Comb. in It 155.00 P90-15-XLPP-RR w/ Mount Pipe 35 47.757 2.7542 0.0012 19957 140.00 2) ETf19V2S12UB 35 39.177 2.6693 0.0012 5255 120.00 2) RA21.7770.00 w/ Mount Pipe 35 28.556 2.3827 0.0010 3401 0.00 2) 7'x2" Antenna Mount Pipe 0 0.000 0.0000 0.0000 23892 tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. L1 159 - 133.42 127.331 11 7.0431 0.0030 L2 136.587 - 87.837 94.834 11 6.7082 0.0029 0 92.1703 - 41.294 11 4.4826 0.0019 43.2903 L4 48.707 - 0 10.949 10 2.0970 0.0009 July 18, 2012 CCI BU No 878532 Page 17 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in oft 155.00 P90-15-XLPP-RR w/ Mount Pipe 11 121.432 7.0070 0.0030 8065 140.00 2) ETT19V2S12UB 11 99.646 6.7918 0.0029 2121 120.00 2) RA21.7770.00 w/ Mount Pipe 11 72.665 6.0642 0.0026 1364 0.00 2) 7'x2" Antenna Mount Pipe 0 0.000 0.0000 0.0000 9383 Compression Checks Pole Design Data Section Elevation Size L L" KI/r F. A Actual Allow. Ratio No. P Pe P ft ft ft ksi in2 K K p° L1 159 - 133.42 TP21.29x16x0.1875 25.58 0.00 0.0 39.000 12.1689 -3.23 474.58 0.007 1) L2 133.42- TP30.21x20.26014.25 48.75 0.00 0.0 39.000 23.0715 -10.09 899.79 0.011 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 48.88 0.00 0.0 39.000 37.0784 -16.84 1446.06 0.012 43.2903(3) L4 43.2903 - 0 (4) TP47x37.0697x0.375 48.71 0.00 0.0 39.000 55.4954 -27.65 2164.32 0.013 Pole Bending Design Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. Mx fax Fbx fax My fby Fby fby ft kip-ft ksi ksi Fbx kip-ft ksi ksi FbV L1 159 - 133.42 TP21.29x16x0.1875 77.81 15.226 39.000 0.390 0.00 0.000 39.000 0.000 1) L2 133.42 - TP30.21x20.26014.25 579.54 42.044 39.000 1.078 0.00 0.000 39.000 0.000 87.837(2) L3 87.837 - TP38.8x28.8256x0.3125 1286.0 45.144 39.000 1.158 0.00 0.000 39.000 0.000 43.2903(3) 7 L4 43.2903-0 TP47x37.0697x0.375 2240.7 42.122 39.000 1.080 0.00 0.000 39.000 0.000 4) 9 Pole Shear Design Data tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 Section Elevation No. ft L1 159 - 133.42 1) L2 133.42 - 87.837 (2) L3 87.837 - 43.2903 (3) L4 43.2903 - 0 4) July 18, 2012 CC/ BU No 878532 Page 18 Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio V f Fv f T ft Fw ft K ksi ksi F kip-ft ksi ksi FN TP21.29x16x0.1875 6.87 0.565 26.000 0.043 0.00 0.000 26.000 0.000 TP30.21x20.2601x0.25 14.52 0.629 26.000 0.048 0.00 0.000 26.000 0.000 TP38.8x28.8256x0.3125 17.89 0.483 26.000 0.037 0.00 0.000 26.000 0.000 TP47x37.0697x0.375 21.22 0.382 26.000 0.029 0.00 0.000 26.000 0.000 Section Elevation Ratio No. P It Pa L1 159 - 133.42 0.007 1) L2 133.42 - 0.011 87.837(2) L3 87.837 - 0.012 43.2903(3) L4 43.2903 - 0 0.013 4) Section Elevation No. It L1 159 - 133.42 L2 133.42 - 87.837 L3 87.837 - 43.2903 L4 43.2903 - 0 Pole Interaction Design Data Ratio Ratio Ratio Ratio Comb. Allow. Criteria fbx fbY f„ ft Stress Stress Fbx Fbv Fv FK Ratio Ratio 0.390 0.000 0.043 0.000 0.398 1.333 H1-3+Vf 1.078 0.000 0.048 0.000 1.090 1.333 I/ H1-3+VT 1.158 0.000 0.037 0.000 1.170 1.333 t/ H1-3+VT 1.080 0.000 0.029 0.000 1.093 1.333 V H1-3+VT Section Capacity Table Component Size Critical P Type Element K Pole TP21.29xl6x0.1875 1 -3.23 Pole TP30.21x20.26014.25 2 -10.09 Pole TP38.8x28.8256x0.3125 3 -16.84 Pole TP47x37.0697x0.375 4 -27.65 SF'Penw Pass K Capacity Fail 632.62 29.8 Pass 1199.42 81.8 Pass 1927.60 87.7 Pass 2885.04 82.0 Pass Summary Pole (1-3) 87.7 Pass RATING = 87.7 Pass tnxTower Report - version 6.0.4.0 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 1»=1kiIDIEa-? BASE LEVEL DRAWING July 18, 2012 CCI BU No 878532 Page 19 tnxTower Report - version 6.0.4.0 D 159 Ft Monopole Tower Structural Analysis Project Number 511647, Application 149920, Revision 0 APPENDIX C ADDITIONAL CALCULATIONS July 18, 2012 CCI BU No 878532 Page 20 tnxTower Report - version 6.0.4.0 Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces BU#: 878532 TIA Revision: F Site Name: F1/MONTICELLO/FULFILLMENT Max. Service Shaft M: 2431.41 ft-kips (* Note) App #: 149920 Rev. 0 Max. Service Shaft P: 28 kips Max Axial Force Type: Comp. Note: Max Shaft Superimposed Moment does not necessarily Enter Load Factors Below: equal to the shaft top reaction moment For M (WL) 1.3 <---- Enter Factor For P (DL) 1 1.3 I <--- Enter Factor Pier Properties Concrete: Pier Diameter =1 6.5 Ift Concrete Area = 4778.4 in Reinforcement. Clear Cover to Tie= 3.00 Horiz. Tie Bar Size= 5 lin Vert. Cage Diameter = 5.78 ft Vert. Cage Diameter = 69.34 in Vertical Bar Size 11 Bar Diameter = 1.41 in Bar Area = 1.56 in Number of Bars 20 As Total= 31.2 in' A s/ Aconc, Rho: 0.0065 0.65% ACI 10.5 , ACI 21.10.4, and IBC 1810. Min As for Flexural. Tension Controlled, Shafts: 3)*(Sq rt(f c)/Fy: 0.0032 200 / Fy: 0.0033 Minimum Rho Check: Actual Req'd Min. Rhoj 0.33% IFlexural Provided RhoJ 0.65% 10K Ref. Shaft Max Axial Capacities. (b Max(Pn or Tn): Max Pu = ((p=0.65) Pn.1 Pn per ACI 318 (10-2)I 9366.42 (kips at Mu=(=0.65)Mn= 5297.94 ft-kips MaxTu,((p=0.9)Tn=l 1684.8 1kips at Mu=(=(0.90)Mn= 0.00 Ift-kips Load Factor Shaft Factored Loads 1.30 MU: 3160.832 Ift-kips 1.30 Pu: 36.4 kips ' Material Properties Concrete Comp. strength, fc Reinforcement yield strength, Fy = 60 ksi Reinforcing Modulus of Elasticity, E = 29000 ksi Reinforcement yield strain = 0.00207 Limiting compressive strain = 0.003 ACI 318 Code Select Analysis ACI Code= 1 2002 Seismic Properties Seismic Design Category B Seismic Risk = Low Solve I<- Press Upon Completing All Input Run) II Results: Governing Orientation Case: 2 Mu Mu Case 1 Case 2 Dist. From Edge to Neutral Axis: 11.63 in Extreme Steel Strain, et: 0.0159 et > 0.0050, Tension Controlled Reduction Factor,cp: 0.900 Output Note: Negative Pu=Tension For Axial Compression, cp Pn = Pu: 36.40 kips Drilled Shaft Moment Capacity, cpMn: 4657.35 ft-kips Drilled Shaft Superimposed Mu: 3160.83 ft-kips Mu/9Mn, Drilled Shaft Flexure CSR: 67.9% Drilled -Shaft -Moment -Capacity, DSMC, Version 1.1 - Effective 04/01/ 2010 Analysis Date: 7/18/2012 Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material I TIA Rev 171 Site Data Reactions BU#:878532 Moment: 2241 ft-kips Site Name: F1/MONTICELLO/FULFILL Axial:1 28 kips App #: 149920 Rev. 0 Shear l 22 kips Pole Manufacturer:1 Other I Anchor Rod Data Qty: 1 12 Diam:1 2.25 in Rod Material: A615-J Strength (Fu):1 100 ksi Yield (Fy):l 75 ksi Bolt Circler 56 in If No stiffeners, Criteria: I AISC ASD I< -Only Applcable to Unstiffened Cases Anchor Rod Results Maximum Rod Tension: Allowable Tension: Anchor Rod Stress Ratio: Stiffened 157.7 Kips Service, ASD 195.0 Kips Fty*ASIF 80.9% Pass Plate Data Diam: 62 in Base Plate Results Flexural Check Stiffened Thick: 1.75 in Base Plate Stress: 50.6 ksi Service, ASD Grade: 60 ksi Allowable Plate Stress: 60.0 ksi 0.75*Fy*ASIF Single -Rod B-eff. 12.43 in Base Plate Stress Ratio: 84.4% Pass Y.L. Length: N/A, Roark Stiffener Data (Welding at both sides) Config:1 3 Stiffener Results Weld Type: I Both Horizontal Weld : 32.8% Pass Groove Depth: 0.5 in ** Vertical Weld: 33.8% Pass Groove Angle: 45 degrees Plate Flex+Shear, fb/Fb+(fv/Fv)^2: 6.9% Pass Fillet H. Weld: 0.1875 in Plate Tension+Shear, ft/Ft+(fv/Fv)^2: 33.0% Pass Fillet V. Weld: 0.3125 in Plate Comp. (AISC Bracket): 32.9% Pass Width: 6 in Height:1 18 in Pole Results Thick: 1 in Pole Punching Shear Check: 7.8% Pass Notch] 1 in Grade:1 50 ksi Weld str.: 70 ksi Clear Space between 6 in Stiffeners (b): Pole Data Diam:1 47 in Thick: 0.375 in Grade: 65 ksi of Sides: 18 T" IF Round Ful 80 ksi Reinf. Fillet Weld 0 0" if None Stress Increase Factor ASIF:) 1.333 1 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5 - Circular Base F 1.2, Effective March 19, 2012 Analysis Date: 7/18/2012 Monopole Drilled Pier Checks capacity of a single drilled shaft foundation for a monopole BU#: 878532 Site Name: F1/MONTICELLO/FULFILLMENT SY App Number: 149920 Rev. 0 I Design Reactions Shear, S: 22.00 kips l Moment, Mt: 2241.00 ft-kips l Tower Weight, Wt: 28.00 kips l Tower Height, H: 159 it Base Diameter, BD: 47.0 in Foundation Dimensions Caisson Diameter, CD: 6.5 ft l ExL Above Grade, E: 1.0 it l Depth Below Grade, L: 28.0 it l Neglected Depth, N: 5.0 it l Reber Size, Sp: 11 l Reber Quantity, mp: 20 l Tie Size, tp: 5 Material Properties I Rebar Tensile, Fy: 60 ksi l Concrete Strength, F'c: 4000 psi l Concrete Density, dx: 150 pd l Clear Cover, cc: 3 in ICU V CCAOS -WEN I ACI 318 Version:l 2002 Design Checks Capacity/ Demand/ Availability Limits Check Minimum Req'd Die. 1(it): 6.50 1.63 OK Minimum Req'd Die. 2 (it): 6.50 5.42 OK Bearing (ksl): 13.50 0.84 OK Rebar Area (in 2): 31.20 0.00 OK Pier moment capacity (k-ft): 4657.35 3160.83 OK Reber spacing (in): 9.90 2 < Bs <18 OK Development Length (in): 231.36 12.00 OK Soil moment capacity (FOS): 4.75 2.00 OK ISoil Properties I I Soil Unit Weight, ya 105 I l Allowable Bearing, Bc: 13.500 Ipdksf l l Seismic Design Cat, z: B Caisson Analysis I Depth to Zero Shear: 8.5 it Max Factored Moment: 3160.83 ft-kips l Overturning FOS: 4.75 Depth I Shear I IMoment I 2.9 22.1Pki s 2307.9 ft-kips l 5.8 Iftft 22.1 kips 2372.2 ft-kips l 8.7 it 1.9 kips 2406.2 ft-kips r Assume 0.33%Minimum Steel? Bearing: 6.3 % Steel: 67.9 % Soil: 42.1 % Monopole Drilled Pier (Caisson) Version 1.5 Effective Date: 04/26/2012 878532_Final_caisson.txt CAISSON version 10.40 10:58:26 Am Wednesday, July 18, 2012 Crown Castle USA 4444****A**####ff4f44#4444#*A*******f**##*****A**44*A*A****A*AA***###4#4#4##A******#tr#4d##4 CAISSON - Pier Foundations Analysis and Design - Copyright Power Line Systems, Inc. 1993-2010 * d444*#*********##4*4tr4A*A***4**4A*#******44***4444#4f4**4***#**#***#**4d4444*4***A****#*tr**OA4*#R Project Title: BU# 878532 Project Notes: Calculation method: Full 8CD I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength ft) (ft) (ksi) (ksi) 6.50 1.00 4.00 60.00 soil Properties Layer Type Thickness Depth at Top Density CU of Layer ft) (ft) (lbs/ftA3) (psf) 1 Clay 5.00 0.00 105.0 2 Sand 23.00 5.00 105.0 Design (Factored) Loads at Top of Pier moment Axial Shear Additional Safety Load Load Factor Against Soil Failure ft-k) kips) kips) 2241.0 28.0 22.00 4.75 R E S U L T S Calculated Pier Properties Length Weight End Bearing Pressure ft) kips) psf) 29.000 144.346 843.8 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density to Top of Pier ft) ft) lbs/ftA3) Clay 1.00 5.00 105.0 Sand 6.00 15.50 105.0 Sand 21.50 7.50 105.0 Shear and moments Along Pier Distance below Shear moment Top of Pier with Safety Factor) with Safety Factor) ft) kips) ft-k) 0.00 105.2 10657.7 2.90 105.2 10962.7 5.80 105.2 11267.7 8.70 9.1 11429.4 11.60 185.9 11160.2 14.50 418.8 10296.9 17.40 707.8 8676.8 20.30 1052.8 6137.6 23.20 970.2 2922.0 26.10 513.1 757.6 29.00 0.0 0.0 KP PHI deg) 3.255 32.00 CU KP Force Arm psf) (kips) (ft) 0.00 3.50 3.255 1317.20 15.32 3.255-1212.02 25.44 Shear without Safety Factor) kips) 22.1 22.1 22.1 1.939.1 88.2 149.0 221.6 204.3 108.0 0.0 Page 1 Moment without Safety Factor) ft-k) 2243.7 2307.9 2372.2 2406.2 2349.5 2167.8 1826.7 1292.1 615.2 159.5 0.0 2 All `` S.V,M i§K§\ vq 2 2 2 W Cj- ms LU 2 3 O OO@LLD3 E 4 u i fo NIO m 50.-0. COMPOUND AREA) 24'-7" 25'-5' r w oO O nO i 0 A OAB O 1 11P 3m R oA I IZ I I cyo I I 24 - 8' N N O N N O N O N O O rrlr rrlrrr lrrrrlrrrrlrrrrl 4'- 2- _ O O 1"-0' TIP OF EIOMEYMO ROD 155 Ff IfVF1 (PROPOSED) SPPoM PCS BOTTOM OF TOWER STEEL BASE RATE REF. EL 0.0-\ L — C 140 Ff IEVEL (PROPOSED) J-1—LL-- MOBILE-MOBILER,. OWO. 8785J2JL14UJ& J' uai TOWER MODIFICATION DOC 8) 12231372 E` 120 FT IF'EL( AT&T MOBRTIYREF. DWG. 878532JL120J O'-0' BUSNESS UNT. 878532 TOWER D.A