2025-00198CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS : 406 7TH ST E PIN : 155029002070 LEGAL DESC : LAURING HILLSIDE TERRACE LOT 007 BLOCK 002 PERMIT TYPE : FIRE SAFETY PROPERTY TYPE COMMERCIAL CONSTRUCTION TYPE : FIRE ALARM SYSTEM VALUATION : $ 500.00 NOTE: INSTALL NEW OUTPUT MODULE TO DROP DOORS UPON FIRE ALARM. APPLICANT ELECTRO WATCHMAN INC 1 WATER ST W ST PAUL, MN 55107- 651) 310-1268 OWNER MONTICELLO TRAINING CENTER, LLC 21395 JOHN MILLESS DR ROGERS, MN 55374- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date Z D Z S— 0 0 1 9 8* DATE ISSUED: 03/07/2025 Permit #: 2025-00198 FIRE SUPPRESSION FEE 100.00 PLAN REVIEW - FIRE 65.00 STATE SURCHARGE, OTHER VAL 0.25 TOTAL 165.25 Payment(s) CHECK 135402 165.25 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. le0t6_e2V 4 FIRE PROTECTION/ALARM PERMIT APPLICATION,3•,S 103 CHELSEA ROAD MONTICELLO, MN SS362 Project Address: 406 E 7th Street PHONE: 763-295-3060 no [EEC RE OVE FIE' IL Lot Block Development Legal , - MN Workforce Center. , Owner Telephone E-Mail Address Arrow Companies 763-227-2937 johland@arrowcos.com Contractor License Number E-Mail Address Electro Watchman, Inc. TS000224 jammeyer@electrowatchman.com Mailing Address 1 West Water Street, Suite 110 Saint Paul, MN 55107 Contact Person Jason Kammeyer Property Single Family Two -Family Type Residential Residential CHECK ONE) 7 Commercial Industrial Telephone 651-310-1262 Multifamily Townhome Residential Institutional Public I Gov't Fire Protection Permit Type Fire Wet Sprinklers # of Heads Suppression System Dry Sprinklers —Pressurized # of Heads Chemical, Ansul / Comm Kitchen - OTHER # of Heads Fire Alarm Fire Suppression Monitoring System System IN Building Fire Alarm System Install new output module to drop doors upon fire alarm. Description of work: OTHER FIRE PROTECTION SYSTEM (Specify Type & Number) Signature of Fire Protection Contractor R A"-fy Signature of Owner (If Owner is Builder) Mobile Telephone Agricultural OTHER Project Valuation 500.00 Date 02-24-2025 Date I hereby apply for a Fire Protection permit and acknowledge: the information above is complete and accurate, the work will be in conformance with the ordinances and codes of the City of Monticello and Minnesota State Building and Fire Codes, 1 understand this is not a permit but only an application for permit, work is not to start without permit, work will be in accordance with the Approved Plan when City plan approval required. This application and any issued permit may become null and void if permit is not issued or work is not commenced within 180 days, or if work is suspended or abandoned for a period of 180 days. 1 hereby certify that I have read and examined this application. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. UV - FOR u ONLYPLANCHECKREQUIREDPlansCheckedBy// BPC 65% of Permit Fee„ l Approved for Issuance LJ Date 3- y 2D Fire Protection Permit Fees Proiect Valuation to be used in computing permit fee is the fair market value of work, including the total costs of materials, labor, profit and overhead for which the permit is issued. Minimum Permit Fee (.All Permit Types) Fire Suppression System Fire Alarm System Commercial Fuel Storage Tank Other Fire Protection System Plan Review Fee (Charged For All Permit Types TJ'hen Plans Mast Be Submitted) Minnesota State Surcharge must be charged in addition to permit fees for all permit types: 100.00 1.25% of Project Valuation 1.25% of Project Valuation 1.25% of Project Valuation 1.25% of Project Valuation 65% of Permit Fee 0005 x Project Valuation DO NOT SEND A CHECK WITH YOUR APPLICATION All submissions must be electronic and include the following: Application Plans Spec sheets Email electronic files to Fire.Marshal@MonticelloMN.gov ELECTRO WATCHMAN, INC. FIRE & SECURITY SYSTEMS - SINCE 1921 February 25, 2025 Re: MN Workforce Center 406 East 71h Street Monticello, MN 55362 To whom it may concern, I am submitting this letter in lieu of fire alarm plans since our scope of work for this project is very minimal. We will be installing a relay on the existing fire alarm system to drop power to a door that was recently added at the above -mentioned building. No other changes or additions will be made to the fire alarm system. Please contact me if you have any questions regarding this project. Sincerely, Jason Kammeyer Service Manager 651-310-1262 SECURITY - FIRE - CCTV - ACCESS 1 WEST WATER STREET - SUITE 110 - ST. PAUL. MN 55107 T: 651.227.8461 - F: 651.310.1296 - TF: 800.666.5453 ELECTROWATCHMAN.COM www.boschsecurity.com 4 BOSCH Invented for life r, 1s1/ n The D7053 Multiplex Input-output Module is a general purpose device that monitors a normally -open (NO), supervised contact device and provides a separately controlled Form C relay output. The module connects to the multiplex bus in either a Class A (Style 6) or Class B (Style 4) configuration. All operating power for the module is drawn from the control panel's multiplex bus. Rotary switches allow convenient address setting. An on -board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low -profile faceplate. Notice The D7024 and DS9400M are not listed under UL864, 9th edition. Region Certification USA UL UOJZ: Control Units, System (ANSI/UL 864) and UOXX: Control Unit Accesso- ries, System (ANSI/UL 864) FM D7053 Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard double -gang or four -inch square back box Easy addressing using rotary switches Low current draw UL Listed Region Certification CSFM see our website FDNY- #6173 CoA Compatible Products The following products are compatible with the D7053 Multiplex Input-output Module: Category Product ID Product Description Control D7024 Addressable FACP Panels D7024-EXP Addressable FACP for export DS9400M Addressable FACP FPD-7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the module on a double -gang or four -inch square back box. Wiring Make connections to the terminals on the rear of the module. All terminals can accommodate up to 12 AWG ISO 4 mm2) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA-70). All wiring is power limited and supervised. Notice Do not use shielded wire. Supervise the Class B input loop with the supplied EOL resistor. Quant. Component 1 D7053 module 1 2.21 kO end -of -line (EOL) resistor (P/N: 25899) 1 Literature pack Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Radio Frequency Interference (RFI) Immunity: Relative Humidity: Temperature (operating) Inputs Indoor, dry No setup or alarm on critical frequencies in the range from 26 MHz to 950 MHz for field strengths less than 30 V/m Up to 93% non -condensing 320F to +120°F (0°C to +49°C) Type: One normally -open (NO) Class B (Style B) contact input supervised by a 2.21 kn EOL resistor (P/N 25899). Mechanical Properties Color: White Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.9 oz (110 g) Outputs Alarm: Reports alarm and point number to FACP Relay: One set of Form C (NO/C/NC) contacts rated for 120 VAC at 0.5 A, 24 VDC at 1.0 A, resistive loads only Trouble: Reports trouble and point number to FACP Power Requirements (supplied from FACP's MUX bus) Current: 0.70 mA Voltage (minimum): 8 V peak (12 VDC nominal) D7053 Multiplex Input-output Module The D7053, powered by its connection to the multiplex bus of a D7024, DS9400M, or FPD-7024 FACP in either a Class A (Style 6) or Class B (Style 4) configuration, monitors a normally -open (NO) contact device and provides a separately controlled Form C relay output. It is addressed by rotary switches. Order number D7053 Represented by: Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 3140 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com V Bosch Security Systems 2014 1 Data subject to change without notice 2692090379 1 en, V4, 22. Jul 2014 Asia -Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www. bosch secu rity.asia China: Bosch (Shanghai) Security Systems Ltd 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn America Latina: Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com