Loading...
2025-00034CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS : 4462 86TH ST NE PIN : 155264002130 LEGAL DESC : EDMONSON RIDGE LOT 013 BLOCK 002 PERMIT TYPE : BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE : NEW CONSTRUCTION VALUATION $ 359,533.47 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: 787 SQ FT FINISHED BASEMENT 269 SQ FT UN FINISHED BASEMENT 1,056 SQ FT FINISHED MAIN FLOOR 1,277 SQ FT FINISHED SECOND FLOOR 96 SQ FT OPEN PORCH 700 SQ FT GARAGE FIREPLACE: YES A/C: YES MECHANICAL: 12, RECHER HVAC PLUMBING: 22, NORTHWOODS PLUMBING 2 0 2 5- 0 0 0 3 4* DATE ISSUED: 01/16/2025 Permit #: 2025-00034 SINGLE FAMILY TWO STORY HOME WITH GAS FIREPLACE AND LUXURY SUITE AND FINISHED LOWER LEVEL WATER METER 1 (MAIN) 1.00 SAC UNITS APPLICANT JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55311- 763) 999-7153 OWNER JP BROOKS 13700 REIMER DRIVE MAPLE GROVE, MN 55311- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date BUILDING PERMIT FEE PLAN REVIEW STATE SURCHARGE, B L DG VAL SAC FEE 30% SAC FEE 70% WATER ACCESS CHARGE, RESI COMB CONNECTION FEE / RESI SEWER / WATER EXCAVATION PERMIT CONTRACTOR LICENSE VERIFICATION FEE ASSESSMENT SEARCH FEE UTILITY LOCATE FEE, RESI WATER METER 1 (MAIN) MN STATE SALES TAX (MTR1) TOTAL Payment(s) CHECK 22279 1.00 2,597.78 1,688.56 179.77 1,449.90 3,383.10 2,153.00 130.00 130.00 5.00 60.00 50.00 475.00 35.03 12,337.14 12,337.14 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY OF Monticeflo BUILDING SAFETY PERMIT # JL 505 WALNUT STREET, SUITE I MONTICELLO, MN 55362 City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: LALA W ; Slot", ' Y' QSu _ZONED LEGAL: Lot Block Plat P'l(1 i ( i Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip; 55311 Contractor Name: JP Brooks Builders State License #: 656554 Address: 13700 Reimer Drive Eng./ Architect Name: Address: Plumber Name: Northwoods Plumbing Address: 30799 73rd Street Mechanical Name: Recher HVAC Address: 1125 Mississippi Drive North Type of Work New Addition Alteration Repair Move Other Phone: 763-285-4790 E- Mail: shelly@jpbrooks.com City: Maple Grove State: MN City: City: Pierz City: Champlin Type of Construction X Single Family Duplex n Multi -Family Commercial Industrial Other Phone: State: Phone: 763-717-8757 State: MN Phone: 612-802-6525 State: MN Zip: 55311 Zip: Zip: 56364 Zip: 55316 Building Information Use of building K CAv"' t4-0 , of stories 1--oo/c a&..-r Floor area sq. ft. a ?_j 5 -) Estimated value is11)S'3- .4_7 of construction I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE B K FOR PLU XU AND MECH AL INFO. Applicant Signa> e Applicaitio Date APPLICANT. Please show. fixtures that are applicable. Fire Suppression : (if applicable) Plumbinz: (if applicable) Mechanical. (if applicable) No. Fixture Tvve No. Fixture Tvve No. Fixture Tvve Sprinkler Heads Water Closet (toilet) A Furnace Other /Special FS Device Bathtub Gas Meter 6 Lavatory (wash basin) Range Hood Shower I Gas Range Kitchen Sink ij' Water Heater Dishwasher i Air Conditioning Laundry Tub 1 Mech. Fireplace d Clothes Washer Bathroom(s) Exhaust Fan Fire Alarm: (if applicable) Water Heater Air Exchanger Urinal Dryer No. Fixture Tvpe Drinking Fountain Gas Opening w/o Fixture Floor Drain of Devices Slop Sink Other Outside Faucet Z TOTAL 13 TOTAL FOR CITY USE ONLY i Future Owner Information• Tree Ordinance Handout Yes No Other Handouts Yes No Name: Address: City: ADDITIONAL INFORMATION: c Valuation: State: Zip: Construction Type: 1% a Occupancy Group: Z t Phone #: Division: Square Footage: of Stories: 1 Z, Loa k- o w-? of Residential Units: - Q^ e, Maximum Occupancy: IVA Fire Sprinklers: Yes 'a No Off -Street Parking Covered: 3 Off -Street Parking Uncovered: P, Af Building Official 71W4A41 BPT: / / C-1TY C7f Monticello Address: Legal: New Residence: 2025 Residential Building Permit Calculator 4462 86th St NE Lot 13 Block 2 Edmonson Ridge 1 = Yes 0 = No I House Type: 1 = Yes 0 = No 2 story 1 = Yes 0 = No Permit Applicant: Contractor: I Plan Review: I 11' Brooks Owner: 0 Master Plan: 0 Master Plan Review = 25% ofBuildiUS Permit Fee) I sc A rea June 2016 Valuation Factor TOTAL Crawl Space 0 15.27 $ Unfinished Basement Area 269 16.50 $ 4,438.50 Finished Basement Area 787 44.05 $ 34,667.35 Main/First Floor Area 1,056 125.00 $ 132,000.00 Second Floor Area 1,277 115.00 $ 146,855.00 Detached Garage Attached Garage Garage Conversion to Living Space Carport/Gazebo Pole Barn Shed - greater than 200 SF Lean -to -Shed Basement Finish Only Remodeled Area Porch (open) Porch (3-Season) Porch (3-Season on Existing Deck) Porch (Screen Porch/Breezeway) Solarium Deck Deck (Screen In & Roof Over Existing) In -Ground Pool Above -Ground Pool Fireplace - Mechanical/Gas Fireplace - Masonry Elevator/Lift/Other Water Hook-up Sanitary Sewer Hook-up FEES: 0 700 0 0 0 0 0 0 0 96 0 0 0 0 0 0 0 0 1 0 0 1 = Yes 1 1 60.00 $ 47.33 $ 47.44 $ 30.90 $ 19.03 $ 40.00 $ 13.25 $ 16.00 $ 17.39 $ 36.97 $ 60.00 $ 55.00 $ 58.48 $ 94.90 $ 20.00 $ 29.80 $ 23.18 $ 11.31 $ 4,892.50 $ 22, 660.00 $ CALCULATED BUILDING VALUATION $ O=No 33,131.00 3,549.12 4,892.50 359,533.47 BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,596.74 PLAN CHECK 1,687.88 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 179.77 SUBTOTAL 4,469.38 SEWER FEE [SAC] 4,833.00 WATER FEE ]WAC] 2,153.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 60.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 510.03 SUBTOTAL 7,866.03 TOTAL FEES CALCULATED $ 12,335.41 Escrow Amount - (Winter Only) TOTAL AMOUNT TO BE PAID TO CITY $ 129335.41 CITY OF Ionticello BUILDING SAFETY RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite 1 MONTICELLO, MN 55362 Date: 1 /6/2025 Contractor: City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4462 86th Street NE JP Brooks 13700 Reimer Drive Maple Grove, MN 55311 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: Two Story with gas fireplace and luxury suite Finished lower level 3,120 Sq ft Finished 1 1 Page 131dg Building, Mechanical &Plumbing Bob Ferguson — Chief Building Official 763) 271-3214 Bob. Ferguson(a_,Monticel IoMN.gov Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908 Wa}ne.KallagMonticelloMN.gov_ Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(?MonticelloMN.gov 763) 271-3222 Amy Biren — Building Pen -nit Technician 763) 295-3060 buildin.gdepartmentnMonticelloMN.gov review Electrical Bill Husom — Electrical Inspector (612)490-0488 outside of city Permits I Minnesota Department of Labor and Industry Office Hrs: 7-8:30am mn.v,ov ) 910 — 18th St SE, Buffalo, MN 55313 CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-3224 Aiig,ela.SchumannLwMonticelIoMN.gov Bob Ferguson — Zoning Administrator 763) 271-3214 b. r uson onticelloMN. ov Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer (763)-271-3271 PW Utilities Matt. LeonardaMonticeIIoMN.aov Ryan Melhouse — Project Engineer (763) 271-3227 Rvan.Melhouse(a,MonticelloMN.2ov Mario Frucci — Engineering Technician Mario. FrucciaMonticelloMN.2ov (763) 271-3213 Mat Stang - Water & Sewer Superintendent (763) 271-3274 Mat. Stanv,( ,MonticelloMN.vov The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of the Building Plans and Specifications. 2 1 Page This review is for Building Construction Permit review onk. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ SPEC. CODE SECTION COMMENTS SECTION I Bldg n1a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note 2 bldg n1a general Building Official review and authorization required prior to changes. modifications, note or alterations. 3 bldg n1a general 1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has note been issued. 4 bldg n1a general Final Building, Plumbing, and Heating inspections must be completed prior to note occupancy. Owner or contractor must be present for final building inspection. 5 bldg n1a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note 6 bldg n1a general Separate applications and permits Required for Sewer / Water Connection, Heating note A/C Systems, Plumbing, Fire Alarm Systems. bldg n1a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection N1101.8) Bldg MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F 8 299F .50 50 R315 bldg Buildings must be constructed per current building codes. 2020 MN State Building Code including: n1a general 2020 MN Residential Code 9 note MR 1300 2023 National Electrical Code 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. 11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans 12 bldg n1a general Post Address Card Visible from the street, maintain until the house numbers are note installed. 13 bldg n1a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans note for framing inspection. 14 bldg n1a general State Board of Electricity: Separate Permit and Inspections Required for Electrical note work. 15 bldg Maintain 6" Earth to wood separation Eng Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fence are required. Maintain erosion controls until landscaping is completed. 3 1 Page PLAN NO. DEPT SHEET/ SPEC. SECTION 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 CODE COMMENTS SECTION bldg Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. bldg R312.2 Window Fall Protection Required for all windows 6' above grade with sill height of less than 24", maximum opening must be less than 4". bldg WARNING: Call Before You Dig! Gopher State one 651-454-0002 bldg. a Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not Exceed 3 Air Exchanges Per Hour. bldg Flash between House and Stoop. bldg R319.1 Install House Numbers: 4" minimum, visible from street. bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / damper areas are exposed. bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. bldg R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic. Close horizontal to vertical penetrations. bldg R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly blocked and carried continuously to foundation. bldg Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to daylight; schedule 40 pipe required). bldg R402.4.1.1 Hardboard Backer Required behind tub / shower. bldg Seal and Secure Sump Pump Basket Cover. bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). bldg R405.2.3 Drain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install flexible hose connection extending to drainage area away from the foundation wall. ; bldg R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for Subpart 6 future active radon ventilation system. bldg Radon gas vent pipes shall be provided with space around the vent pipe for future fan R 1303.2402 installation. The space required for the future fan installation shall be a minimum of 24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. bldg R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. bldg R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss manufacture. bldg R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to MN Res -Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code bldg R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: Detached Accessory Buildings) 4 1 P a g e PLAN NO. DEPT SHEET/ SPEC. SECTION b1der 38 39 bldg 40 zoning CODE COMMENTS SECTION 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2°d course of R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, 1 anchor within V of each end. Exterior non -draining foundation insulation requirements: have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to a width Not to Exceed 28 Ft. and the Public Street. 5 1 Page clrvFR MonticelinBUILDINGCARQtY APPROVED PILE Copy REVIEWED FOR CODE COMPLIANCE VQJE'CT TO FIE D INSPECTION Date: j; Signature; ifflof, INDEX SHEET TITLE ITITLE SHEET TYPICAL FRAMING DETAILS ELEvATIONS d ROOD PLAN ILOWER FLOOR PLAN I MAIN FLOOR PLAN I UPPER FLOOR PLAN IELECTRICAL PLANS IELECTRICAL PLANS IINTERIOR ELEVATIONS/CABINETS IBUILDING SECTIONS IBUILDING: SECTIONS IGENERAL NOTES ITYPICAL WALL SECTIONS ITYPICAL DETAILS Jil'PICAL DETAILS J L1J G J W I DRAWING RECORD REVIEW SET 12-06.2024PERMITSET12-09.2024CLIENTSET 12.09.2024 SQUARE FOOTAGE MAIN FLOOR FINISHED UPPER FLOOR FINISHED LOWER FLOOR FINISHED TOTAL FINISHED FOUNDATION OVERALL SQUARE FEET GARAGE TITLE SHEET xx 1056 1277 787 3120 1024 3357 700 low-nom New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Post: panel. BrooksMailingAdressoftheDwellingorDwellingUnit W11", City 1 JP MoYl3n l BUILDERS Name of Residential Contractor MN License Number JP Brooks Builders 686554 THERMAL ENVELOPE RADON CONTROL SYSTEM I CITVQF Type: Check All That Apply X Passive (No Fan) l4lont> cello DUiLD;NG SAFETY o c or other system monitoring APPROVED FILE COPY o FOR CODE COMPLIANCE a a Location (or future location) of Fan: Ziz -v;::',VED T -, Ir rvSPECTION o 0 C 0 o 0- m Attic Q 3 U o J 0lat .901 B 0 Q m m a) -0 c p to N O a) . U Insulation Location ,Y o Z cNa cu U Q j Cn m 0) Ta 5 o E C, c a) a) uL zLL -- i Li iY Other Please Describe Here Below Entire Slab Poly Barrier Foundation Wall x x Exterior and Interior as dictated by code Perimeter of Slab on Grade x Interior Foundation Wall Rim Joist (1st Floor) x Rim Joist (2nd Floor+) x Wall x Ceiling, flat x Ceiling, vaulted x Bay Windows or cantilevered areas x Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: x Not applicable, all ducts located in conditioned space ffi SolarHeatGainCoecient (SHGC): I IR-value MECHANICAL SYSTEMS I Make-up Air Select Type Appliances Heating System Domestic Water Cooling System x Heater Not required per mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Bryant Richmond Bryant Powered Interlocked with exhaust device. Model 915SBO4206OE17 BAC013NR030BNG Describe: Input in 60, 000 CapacityT Output (INOther, describe: Rating or Size BTUS: Gallons:50 in Tons: Ott 5 AFUE or SEER Location of duct or system: Efficiency HSPF% EER Heating Loss Heating Gain Cooling Load Residential Load Calculati q 1 C )" 1 cfm-s round duct OR MECHANICAL VENTILATION SYSTEM I metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type x Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: x Energy Recover Ventilator (ERV) Capacity in cfms: Low: I lHigh: I Location of duct or system: Balanced Ventilation capacity in cfms: Location of fan(s), describe: I Cfm's Capacity continuous ventilation rate in cfms: 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: metal duct Builders Associaton of Minnesota version 101014 Recher HVAC HVAC Load Calculations for 4462 86th Street Prepared By: Friday, December 6, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Project Report General Project Information Project Title: Recher HVAC Project Date: Friday, December 6, 2024 Client Name: 4462 86th Street de si n Data f Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Dry Bulb Wet Bulb Winter: -15 -15 Summer: 88 71 Outdoor Indoor Rel.Hum n/a Rel.lum n/a 44% 50% Elite Software Development, Inc. Recher HVAC Page 2 Indoor Grains Dry Bulb Difference 72 n/a 75 24 ECheck Figures Total Building Supply CFM: 1,014 CFM Per Square ft.: 0.325 Square ft. of Room Area: 3,122 Square ft. Per Ton: 1,322 Volume (ft'): 20,529 Building Loads Total Heating Required Including Ventilation Air: 54,709 Btuh 54.709 MBH Total Sensible Gain: 23,857 Btuh 84 % Total Latent Gain: 4,478 Btuh 16 % Total Cooling Required Including Ventilation Air: 28,334 Btuh 2.36 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Miscellaneous Report System 1 House Input Data Winter: Summer: Duct Sizing_ Inputs Main Trunk Calculate: Yes Use Schedule: Yes Roughness Factor: 0.00300 Pressure Drop: 0.1000 in.wg./10C Minimum Velocity: 0 ft./min Maximum Velocity: 900 ft./min Minimum Height: 0 in. Maximum Height: 0 in. Outside Air Data Outdoor Outdoor Outdoor Drv_ Bulb Wet Bulb Rel.Hum 15 15 100% 88 71 44% Runouts Yes Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min 0 in. 0 in. Winter Infiltration Specified: 0.280 AC/hr Infiltration Actual: Above Grade Volume 96 CFM 0.280 AC/hr X 20,529 Cu.ft. 5,748 X 0.0167 Cu.ft./hr Summer 0.150 AC/hr 51 CFM 0.150 AC/h r X 20,529 Cu.ft. 3,079 X 0.0167 Cu.ft./hr Elite Software Development, Inc. Recher HVAC Page 3 Indoor Indoor Grains Rel.Hum Drv_ Bulb Difference n/a 72 n/a 50% 75 23.51 Total Building Infiltration: 96 CFM 51 CFM Total Building Ventilation: 160 CFM 160 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier.- 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier.- 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr (96 CFM), Construction: Average Summer Infiltration Specified: 0.150 AC/hr (51 CFM), Construction- Average auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Elite Software Development, Inc. Recher HVAC Page 4 Load Preview Report Net ft.' Sen Lat Net Sen Hts9 s Cl9 Sys Act Duc Scope Ton lTon Area: Gain Gain Gain' Loss CFM CFM CFM Sid Building 2.36 1,322 3,122 23,857 4,478 28,334 54,709 533 1,014 1,014 Svstem 1 2.36 1,322 3,122 23,857 4,478 28,334 54,709 533 1,014 1,014 12x1f Ventilation 2,220 2,482 4,702 14,856 Zone 1 3,122 21,637 1,996 23,633 39,853 533 1,014 1,014 12x1 f 1- Lower Level 789 3,789 245 4,034 8,206 110 178 178 2-- 2- Main Level 1,056 8,052 392 8,444 15,635 209 377 377 4 3- Upper Level 1,277 9,795 1,359 11,154 16,012 214 459 459 5- auerfiles\ FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC PI mouth MN 55441 Page 5 Duct Size Pre vie w Room or Source Minimurr( Maximum Rough; Design SP, Duct_ Duct' Htg Gig Act. _ Duct Duct Name Velocity Velocity Factor L/100 Loss` Velocity Length Flow ;_._Flow Flow Size Svstem 1 Supply Runouts Zone 1 1-Lower Level Built -In 0 750 0.01 0.1 452.1 110M 178 2--6 2-Main Level Built -In 0 750 0.01 0.1 480.3 209M 377 4-- 3-Upper Level Built -In 0 750 0.01 0.1 467.4 214M 459 5-- Other Ducts in System 1 Supply Main Trunk Built -In 0 900 0.003 0.1 810.9 533 1,014 12x1 Summary Svstem 1 Heating Flow: 533 Cooling Flow: 1014 auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Elite Software Development, Inc. Recher HVAC Plymouth, MN 55441 Pa e 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Marvin: Glazing -Marvin, U-value 0.34, SHGC 0.32 328.4 9,716 0 10,325 10,325 11P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292 15BO-10sf-8: Wall -Basement, , R-10 board insulation to 832 3,619 0 0 0 floor, no interior finish, 8' floor depth, U-value 0.05 15BO-10sf-4: Wall -Basement, , R-10 board insulation to 144 677 0 0 0 floor, no interior finish, 4' floor depth, U-value 0.054 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 2185.6 12,360 0 1,890 1,890 cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-50: Roof/Ceiling-Under Attic with Insulation on Attic 1276.8 2,222 0 1,226 1,226 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21 B-20: Floor -Basement, Concrete slab, any thickness, 2 788.8 1,304 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 Subtotals for structure: 30,958 0 13,733 13,733 People: 6 1,200 1,380 2,580 Equipment: 0 3,600 3,600 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 96, Summer CFM: 51 8,895 796 712 1,508 Ventilation: Winter CFM: 160, Summer CFM: 160 14,856 2,482 2,220 4,702 Exhaust: Winter CFM: 160, Summer CFM: 160 AED Excursion: 0 0 2,212 2,212 Total Building Load Totals: 54,709 4,478 23,857 28,334 Check Figures Total Building Supply CFM: 1,014 CFM Per Square ft.: 0.325 Square ft. of Room Area: 3,122 Square ft. Per Ton: 1,322 Volume (ft3): 20,529 Building Loads Total Heating Required Including Ventilation Air: 54,709 Btuh 54.709 MBH Total Sensible Gain: 23,857 Btuh 84 Total Latent Gain: 4,478 Btuh 16 Total Cooling Required Including Ventilation Air: 28,334 Btuh 2.36 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Buildinq Pie Chart Wall 30% Glass 36% Floor 2% Roof 4% Glass 18% Roof 4% Wall 7% Elite Software Development, Inc. Recher HVAC Page 71 Ventilation 27% Infiltration 16% Door 2% AED Excursion 8% Door 1% People 9% Ventilation 17% Infiltration 5% Equipment 13% auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Elite Software Development, Inc. Recher HVAC Plymouth, MN 55441 Pa e 8 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure_) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 28.2 ft. System Number: 1 Room Width: 28.0 ft. Zone Number: 1 Area: 788.8 sq.ft. Supply Air: 178 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.7 AC/hr Volume: 6,310 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 33 CFM Runout Air: 89 CFM Percent of Supply.: 19 Runout Duct Size: 6 in. Actual Summer Vent.: 28 CFM Runout Air Velocity: 452 ft./min. Percent of Supply: 16 Runout Air Velocity: 452 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.128 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area -U- Htg Sen Clg Lat Sen E -Wall-15BO-1 Osf-8 36 X 8 288 0.050 4.4 1,253 0.0 0 0 S -Wall-1 5BO-1 Osf-8 34 X 8 272 0.050 4.4 1,183 0.0 0 0 N -Wall-15BO-10sf-8 34 X 8 272 0.050 4.4 1,183 0.0 0 0 W -Wall-15BO-10sf-4 36 X 4 144 0.054 4.7 677 0.0 0 0 W -Wall-12F-Osw 36 X 4 90 0.065 5.7 509 0.9 0 78 W -GIs-Marvin shgc-0.32 0%S (3) 54 0.340 29.6 1,596 34.3 0 1,854 Floor-21 B-20 28 X 28.2 788.8 0.019 1.7 1.304 0.0 0 0 Subtotals for Structure: 7,705 0 1,932 Infil.: Win.: 5.4, Sum.: 2.9 144 3.479 501 0.278 45 40 AED Excursion: 387 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 0 1,200 Room Totals: 8,206 245 3,789 auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Elite Software Development, Inc. Recher HVAC Plvmouth. MN 55441 Page 9 FDetai1edRoomLoads-__Room 2 - Main Level (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 33.0 ft. System Number: 1 Room Width: 32.0 ft. Zone Number: 1 Area: 1,056.0 sq.ft. Supply Air: 377 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 9,504 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 63 CFM Runout Air: 94 CFM Percent of Supply.: 17 % Runout Duct Size: 6 in. Actual Summer Vent.: 60 CFM Runout Air Velocity: 480 ft./min. Percent of Supply: 16 % Runout Air Velocity: 480 ft./min. Actual Winter Infil.: 47 CFM Actual Loss: 0.144 in.wg./100 ft. Actual Summer Infil.: 25 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain E -Wall-12F-Osw 36 X 9 252 0.065 5.7 1,425 0.9 0 218 S -Wall-12F-Osw 34 X 9 306 0.065 5.7 1,730 0.9 0 265 W -Wall-12F-Osw 36 X 9 228 0.065 5.7 1,289 0.9 0 197 N -Wall-12F-Osw 34 X 9 294 0.065 5.7 1,663 0.9 0 254 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,030 W -GIs-Marvin shgc-0.32 0%S 9 0.340 29.6 266 34.3 0 309 W -GIs-Marvin shgc-0.32 0%S 42 0.340 29.6 1,242 34.3 0 1,442 W -GIs-Marvin shgc-0.32 0%S (3) 45 0.340 29.6 1,332 34.3 0 1,545 N -GIs-Marvin shgc-0 32.1.00%%_ 12 _ 0 340 2.9 6 . 35.5 10.5 0 126_ Subtotals for Structure: 11,250 0 5,678 Infil.: Win.: 47.2, Sum.: 25.3 1,260 3.480 4,385 0.279 392 351 AED Excursion: 823 Equipment: 0 1,200 Room Totals: 15,635 392 8,052 auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8.39 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 10 LDe_t__a_iled___R_oom__ Loads - Room 3 -Upper Level (Average Load Procedurj General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 36.5 ft. System Number: 1 Room Width: 35.0 ft. Zone Number: 1 Area: 1,276.8 sq.ft. Supply Air: 459 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 10,214 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 64 CFM Runout Air: 92 CFM Percent of Supply.: 14 % Runout Duct Size: 6 in. Actual Summer Vent.: 72 CFM Runout Air Velocity: 467 ft./min. Percent of Supply: 16 % Runout Air Velocity: 467 ft./min. Actual Winter Infil.: 43 CFM Actual Loss: 0.136 in.wg./100 ft. Actual Summer Infil.: 23 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantitv Value HTM Loss HTM Gain Gain E -Wall-12F-Osw 36 X 8 247.6 0.065 5.7 1,400 0.9 0 214 S -Wall-12F-Osw 36 X 8 268 0.065 5.7 1,516 0.9 0 232 W -Wall-12F-Osw 36 X 8 227 0.065 5.7 1,284 0.9 0 196 N -Wall-12F-Osw 36 X 8 273 0.065 5.7 1,544 0.9 0 236 E -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,030 E -GIs-Marvin shgc-0.32 0%S (2) 10.4 0.340 29.6 308 34.4 0 358 S -GIs-Marvin shgc-0.32 0%S 20 0.340 29.6 592 19.0 0 380 W -GIs-Marvin shgc-0.32 0%S 16 0.340 29.6 473 34.3 0 549 W -GIs-Marvin shgc-0.32 0%S (3) 45 0.340 29.6 1,332 34.3 0 1,545 N -GIs-Marvin shgc-0.32 100%S 15 0.340 29.6 444 10.5 0 157 UP-Ceil-16B-50 36.5 X 35 1276.8 0.020 1.7 2,222 1.0 0 1,226 Subtotals for Structure: 12,003 0 6,123 Infil.: Win.: 43.2, Sum.: 23.1 1,152 3.480 4,009 0.279 359 321 AED Excursion: 1,001 People: 200 lat/per, 230 sen/per: 5 1,000 1,150 Equipment: 0 1,200 Room Totals: 16,012 1,359 9,795 auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 System 1 Room Load Summary Htg Min Run Run Clg Room No Area Sens Htg Duct Duct Sens Name SF Btuh CFM Size Vel Btuh_ Zone 1--- 1 Lower Level 789 8,206 110 2-6 452 3,789 2 Main Level 1,056 15,635 209 4-6 480 8,052 3 Upper Level 1,277 16,012 214 5-6 467 9,795 Ventilation 14,856 2,220 System 1 total 3,122 54,709 533 23,857 System 1 Main Trunk Size: 12x15 in. Velocity: 811 ft./min Loss per 100 ft.-. 0.099 in.wg Cooling System Summary Elite Software Development, Inc. Recher HVAC Page 1 Clg Min Act Lat Clg Sys Btuh CFM CFM 245 178 178 392 377 377 1,_359 459 459. 2,482 4,478 1,014 1,014. Cooling Sensible/ Latent Sensible LdM1It ota Tons Split _ Btuh _ Btuh _ Btuh Net Required: 2.36 84% / 16% 23,857 4,478 28,334 Equipment Data Cooling SystemHeatingS_ Type: sytem Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8.39 AM X 967.5 / se k Drainage and Utility Easements are shown thus: L6 12 6 12 N.T.S. Being 6 feet in width and adjoining lot lines and 12 feet in width and adjoining street lines and rear lot lines as shown on this plat, unless otherwise shown. r-ram r• .. i 155-264-0030/0 \ k Ede~ '1 ''` }i -• \ 968 6- 24.0 'O 4 00, A96V -•'Q ? O) 4x ? 1 967 84968,0 T9s Ir ° 06 Sp 6$ 0 \ 6S Ar ... w55 hProposed • 1 6X 1 967.8 ,o Garage A) X 966 9 X 964.9 .1IP yip i o .S 96a.4 1 Opp 0 30 1 I 9 / 2.5'i 9 • S k 12 l Prop d. 3 X 969. 0 _ j fro ' '/o ? H 62+96 g 14 X961. 5 6k — I--- • SCALE: I" 30' Spa v` 1 jo' g69.3 ` I 965 8 6.51 ; 9 w 97a18 + \ .• / Tot g1•e X ti oa c 9 PROXCT BENCHMARK: Top of hub w/tock at NW'ly buildingy ArO 9682 `j'3 I comer offset I- 7 L E/evotion - 968.79 feet (Plot Datum) Cr Al ° PID: 15 264-0021 I A- UOkNsArea15,43/ S.F. ON A c } 1 Y 4h w Certificate of Survey® ford! h ono oJPBrooksBuildersac, b Lot 13, Block 2, EDMONSON RIDGE Cit of Monticello, Wightht County, Minnesota Adlafraeel: 4462 86TH STREET ALE AkInd eft MN 65W2 NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. OFFSETS LEGEND: O(eM) OS,/'2 967.84 O Denotes set iron monument OS,/'3 = 967.76 Denotes set hub 0S#4 = 970.I8 Denotes set lath x 976.4 Denotes existing ground elevation Denotes found iron monument 942.. Denotes proposed elevation Denotes proposed drainage flow Denotes electric service T Denotes telephone pedestal Denotes cable television box FO Denotes fiber optic service box Denotes water service (per plan) Denotes sanitary service (per plan) Denotes sanitary manhole (per plan) H Denotes watervolve (per plan) Denotes hydrant (per plan) i Denotes bituminous surface (per plan) Denotes easement 960 Denotes contour per grading plan Denotes sanitary sewer (per plan) Denotes waterline (per plan) g68 5 CS 3 ` 9s) 0.35% Ac.) I o ` SETBACKS HOUSE TYPE 677F{j Landscape / / \ j (' , 7' Front Lu BuutementVVV7' SideEdge I A- 30' Rear rt House 90 \ 3 & 20' Side Street P.U.D. 458 Mow Lin g1 i I dh • nn `` DR/ VEWAY AREA TD STREET: i4 / ry \ !'_ , I m I, 934 V S. F. b / + ,o o I 4'rj I I ,SOO AREA, o O O 0 1 Full Yob - 14,85/7c S.F. i i \ a) O ° I k i 30' Behind House - 7,334% SF. PID: 155-264-002120 I h y PROPOSED IMPERVIOUS Sll?FACES o, I Total lot Area - 15,431!4 S.F. House Area = 1, 825Y- S. F. 0 / 1z DrivewQZ/Wdk Area = 736 .SF. 0* Total impervious Area = 2,56/4 S.F. (16.5X) ELEV PER GRADING PLAN r. , r, l r Pions by Alliant. Garage Floor Elev - 97L 0 Lowest Floor Elevation = 964.0 12 155 Rear Elevation = 968.0 6 J L - Lookout 96 I REFERENCE BENCHMARK,• T er Rim of sanitary manhole on 86th St. NE near West plot boundary. r% i r. .. r- \ PCu' Elevation = 957.15 feet (Plot Datum) PROPM DING SURVEY - /P y:• I PROPOSED HOUSE ELEVA LIONS Open Top of Foundation Elev = 972.7 (H Approved Date 12/23/2024 / I Top of Foundation Elev = 97L 7 (Garage) Garage Floor E/ev = 97L4 L t F/ El — 964 7 House) SHEET NO. I Certificate of Survey BOGART, PEDERSON JP Brooks Builders & ASSOCIATES, INC. L139 B2, EDMONSON RIDGE CIVIL D SURVEYING ENGINEERING NG Wright County, Minnesota 3076IFI FIRST STREET, BECKER, MN 55308-9322 TEL: 763-262-8822 FAX: 763-262-8844 owes Oor ev — Lowest Opening Elev = 967.9 1 hereby certify that this survey, plan, or report was prepared by me or under my DATE: 12/ 10/24 my direct supervision, and that I am a duly Licensed Land Surveyor under the DESIGN BY: laws of the State of Minnesota. DRAWN BY: ZH CHECKED BY:CAW DWG FILE: L13 B2 HS g A. Wensmann FILE NO.: Date: 12/13/24 Reg. No.47466 REV NO. DATE DESCRIPTION