2025-00034CITY OF MONTICELLO
505 WALNUT STREET
MONTICELLO, MN 55362-
763) 295-3060 FAX: (763) 295-4404
ADDRESS : 4462 86TH ST NE
PIN : 155264002130
LEGAL DESC : EDMONSON RIDGE
LOT 013 BLOCK 002
PERMIT TYPE : BUILDING
PROPERTY TYPE SINGLE FAMILY -DETACHED
CONSTRUCTION TYPE : NEW CONSTRUCTION
VALUATION $ 359,533.47
NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME:
787 SQ FT FINISHED BASEMENT
269 SQ FT UN FINISHED BASEMENT
1,056 SQ FT FINISHED MAIN FLOOR
1,277 SQ FT FINISHED SECOND FLOOR
96 SQ FT OPEN PORCH
700 SQ FT GARAGE
FIREPLACE: YES
A/C: YES
MECHANICAL: 12, RECHER HVAC
PLUMBING: 22, NORTHWOODS PLUMBING
2 0 2 5- 0 0 0 3 4*
DATE ISSUED: 01/16/2025
Permit #: 2025-00034
SINGLE FAMILY TWO STORY HOME WITH GAS FIREPLACE AND LUXURY SUITE AND FINISHED LOWER LEVEL
WATER METER 1 (MAIN) 1.00 SAC UNITS
APPLICANT
JP BROOKS HOMES
13700 REIMER DRIVE
SUITE 100
MAPLE GROVE, MN 55311-
763) 999-7153
OWNER
JP BROOKS
13700 REIMER DRIVE
MAPLE GROVE, MN 55311-
AGREEMENT AND SWORN STATEMENT
I agree that the work will be conducted in conformance with
the ordinances of the City of Monticello and with the
Minnesota State Building Code. I understand that the work
will be in accordance with the plan that has been approved
by the Building Official. I agree that any damage caused to
public property including but not limited to curb, sidewalk,
public utilities and signs will be repaired at my expense.
Applicant
Date
Bldg Official Date
BUILDING PERMIT FEE
PLAN REVIEW
STATE SURCHARGE, B L DG VAL
SAC FEE 30%
SAC FEE 70%
WATER ACCESS CHARGE, RESI
COMB CONNECTION FEE / RESI
SEWER / WATER EXCAVATION PERMIT
CONTRACTOR LICENSE VERIFICATION FEE
ASSESSMENT SEARCH FEE
UTILITY LOCATE FEE, RESI
WATER METER 1 (MAIN)
MN STATE SALES TAX (MTR1)
TOTAL
Payment(s)
CHECK 22279
1.00
2,597.78
1,688.56
179.77
1,449.90
3,383.10
2,153.00
130.00
130.00
5.00
60.00
50.00
475.00
35.03
12,337.14
12,337.14
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
CITY OF
Monticeflo
BUILDING SAFETY PERMIT # JL
505 WALNUT STREET, SUITE I MONTICELLO, MN 55362
City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404
BUILDING PERMIT APPLICATION
Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED.
SITE ADDRESS: LALA W ; Slot", ' Y' QSu _ZONED LEGAL:
Lot Block Plat P'l(1 i ( i Property
Owner Name: JP Brooks Builders Phone: 763-285-4790 Address:
13700 Reimer Drive City: Monticello State: MN Zip; 55311 Contractor
Name: JP Brooks Builders State
License #: 656554 Address:
13700 Reimer Drive Eng./
Architect Name: Address:
Plumber
Name: Northwoods Plumbing Address:
30799 73rd Street Mechanical
Name: Recher HVAC Address:
1125 Mississippi Drive North Type
of Work New
Addition
Alteration
Repair
Move
Other
Phone:
763-285-4790 E-
Mail: shelly@jpbrooks.com City:
Maple Grove State: MN City:
City:
Pierz City:
Champlin Type
of Construction X
Single Family Duplex
n
Multi -Family Commercial
Industrial
Other
Phone:
State:
Phone:
763-717-8757 State:
MN Phone:
612-802-6525 State:
MN Zip:
55311 Zip:
Zip:
56364 Zip:
55316 Building
Information Use
of building K
CAv"'
t4-0 , of
stories 1--oo/c a&..-r Floor
area sq. ft. a ?_j 5 -) Estimated
value is11)S'3- .4_7 of
construction I
hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree
that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and
that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be
in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not
limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE
B K FOR PLU XU AND
MECH AL INFO. Applicant
Signa> e Applicaitio Date
APPLICANT. Please show. fixtures that are applicable.
Fire Suppression : (if applicable) Plumbinz: (if applicable) Mechanical. (if applicable)
No. Fixture Tvve No. Fixture Tvve No. Fixture Tvve
Sprinkler Heads Water Closet (toilet) A Furnace
Other /Special FS Device Bathtub Gas Meter
6 Lavatory (wash basin) Range Hood
Shower I Gas Range
Kitchen Sink ij' Water Heater
Dishwasher i Air Conditioning
Laundry Tub 1 Mech. Fireplace
d Clothes Washer Bathroom(s) Exhaust Fan
Fire Alarm: (if applicable) Water Heater Air Exchanger
Urinal Dryer
No. Fixture Tvpe Drinking Fountain Gas Opening w/o Fixture
Floor Drain
of Devices Slop Sink
Other Outside Faucet
Z TOTAL 13 TOTAL
FOR CITY USE ONLY i
Future Owner Information• Tree Ordinance Handout Yes No
Other Handouts Yes No
Name:
Address:
City: ADDITIONAL INFORMATION: c
Valuation:
State: Zip: Construction Type: 1% a
Occupancy Group: Z t
Phone #: Division:
Square Footage:
of Stories: 1 Z, Loa k- o w-?
of Residential Units: - Q^ e,
Maximum Occupancy: IVA
Fire Sprinklers: Yes 'a No
Off -Street Parking Covered: 3
Off -Street Parking Uncovered:
P, Af
Building Official 71W4A41
BPT: / /
C-1TY C7f
Monticello
Address:
Legal:
New Residence:
2025 Residential Building Permit Calculator
4462 86th St NE
Lot 13 Block 2 Edmonson Ridge
1 = Yes 0 = No
I House Type:
1 = Yes 0 = No
2 story
1 = Yes 0 = No
Permit Applicant: Contractor: I Plan Review: I
11' Brooks Owner: 0 Master Plan: 0
Master Plan Review = 25% ofBuildiUS Permit Fee)
I sc A rea June 2016 Valuation Factor TOTAL
Crawl Space 0 15.27 $
Unfinished Basement Area 269 16.50 $ 4,438.50
Finished Basement Area 787 44.05 $ 34,667.35
Main/First Floor Area 1,056 125.00 $ 132,000.00
Second Floor Area 1,277 115.00 $ 146,855.00
Detached Garage
Attached Garage
Garage Conversion to Living Space
Carport/Gazebo
Pole Barn
Shed - greater than 200 SF
Lean -to -Shed
Basement Finish Only
Remodeled Area
Porch (open)
Porch (3-Season)
Porch (3-Season on Existing Deck)
Porch (Screen Porch/Breezeway)
Solarium
Deck
Deck (Screen In & Roof Over Existing)
In -Ground Pool
Above -Ground Pool
Fireplace - Mechanical/Gas
Fireplace - Masonry
Elevator/Lift/Other
Water Hook-up
Sanitary Sewer Hook-up
FEES:
0
700
0
0
0
0
0
0
0
96
0
0
0
0
0
0
0
0
1
0
0
1 = Yes
1
1
60.00 $
47.33 $
47.44 $
30.90 $
19.03 $
40.00 $
13.25 $
16.00 $
17.39 $
36.97 $
60.00 $
55.00 $
58.48 $
94.90 $
20.00 $
29.80 $
23.18 $
11.31 $
4,892.50 $
22, 660.00 $
CALCULATED BUILDING VALUATION $
O=No
33,131.00
3,549.12
4,892.50
359,533.47
BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,596.74
PLAN CHECK 1,687.88
CONTRACTOR LICENSE VERIFICATION 5.00
STATE SURCHARGE 179.77
SUBTOTAL 4,469.38
SEWER FEE [SAC] 4,833.00
WATER FEE ]WAC] 2,153.00
WATER / SEWER CONNECTION FEE 130.00
SEWER/WATER EXCAVATION PERMIT FEE 130.00
ASSESSMENT SEARCH 60.00
UTILITY LOCATES 50.00
5/8" WATER METER & SALES TAX 510.03
SUBTOTAL 7,866.03
TOTAL FEES CALCULATED $ 12,335.41
Escrow Amount - (Winter Only)
TOTAL AMOUNT TO BE PAID TO CITY $ 129335.41
CITY OF
Ionticello
BUILDING SAFETY
RESIDENTIAL PLANS EXAMINING REPORT
505 Walnut Street, Suite 1
MONTICELLO, MN 55362
Date: 1 /6/2025
Contractor:
City Hall (763) 295-2711
Building Inspections (763) 295-3060
JP Brooks
4462 86th Street NE
JP Brooks
13700 Reimer Drive
Maple Grove, MN 55311
Telephone: 763-285-4790
BASIC PROJECT DESCRIPTION:
Two Story with gas fireplace and
luxury suite
Finished lower level
3,120 Sq ft Finished
1 1 Page
131dg Building, Mechanical &Plumbing Bob Ferguson — Chief Building Official 763) 271-3214
Bob. Ferguson(a_,Monticel IoMN.gov
Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908
Wa}ne.KallagMonticelloMN.gov_
Mark Gerber — Inspector / Plan Reviewer
Mark.Gerber(?MonticelloMN.gov 763) 271-3222
Amy Biren — Building Pen -nit Technician 763) 295-3060
buildin.gdepartmentnMonticelloMN.gov
review Electrical Bill Husom — Electrical Inspector (612)490-0488
outside
of city Permits I Minnesota Department of Labor and Industry Office Hrs: 7-8:30am
mn.v,ov )
910 — 18th St SE, Buffalo, MN 55313
CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-3224
Aiig,ela.SchumannLwMonticelIoMN.gov
Bob Ferguson — Zoning Administrator 763) 271-3214
b. r uson onticelloMN. ov
Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer (763)-271-3271
PW Utilities Matt. LeonardaMonticeIIoMN.aov
Ryan Melhouse — Project Engineer (763) 271-3227
Rvan.Melhouse(a,MonticelloMN.2ov
Mario Frucci — Engineering Technician
Mario. FrucciaMonticelloMN.2ov (763) 271-3213
Mat Stang - Water & Sewer Superintendent (763) 271-3274
Mat. Stanv,( ,MonticelloMN.vov
The plan review accomplished as indicated in this record is limited to those code sections specifically
identified herein. This record references commonly applicable code sections. It does not reference all code
provisions which may be applicable to specific buildings. This record is designed to be used only by those
who are knowledgeable and capable of exercising competent judgment in evaluating construction
documents for code compliance.
The following notations refer to design submittal documents as presented in application for a building permit. This report is
not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota
Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of
the Building Plans and Specifications.
2 1 Page
This review is for Building Construction Permit review onk. All other reviews will be conducted with
their respective permit applications. See note #1 below.
PLAN
NO. DEPT SHEET/
SPEC.
CODE
SECTION
COMMENTS
SECTION
I Bldg n1a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area
note
2
bldg n1a general Building Official review and authorization required prior to changes. modifications,
note or alterations.
3
bldg n1a general
1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has
note been issued.
4
bldg n1a general Final Building, Plumbing, and Heating inspections must be completed prior to
note occupancy. Owner or contractor must be present for final building inspection.
5 bldg n1a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction.
note
6
bldg n1a general Separate applications and permits Required for Sewer / Water Connection, Heating
note A/C Systems, Plumbing, Fire Alarm Systems.
bldg n1a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted
7 note Subp 15 in a permanently visible location prior to final inspection
N1101.8)
Bldg MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F
8 299F .50 50
R315
bldg Buildings must be constructed per current building codes. 2020 MN State Building
Code including:
n1a general
2020 MN Residential Code
9
note
MR 1300 2023 National Electrical Code
2020 MN Plumbing Code
2020 MN Mechanical Code
2020 MN Fire Code
bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive.
10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure
treated lumber must be approved for such use.
11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans
12
bldg n1a general Post Address Card Visible from the street, maintain until the house numbers are
note installed.
13
bldg n1a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans
note for framing inspection.
14
bldg n1a general State Board of Electricity: Separate Permit and Inspections Required for Electrical
note work.
15 bldg Maintain 6" Earth to wood separation
Eng Erosion Control Required: Install erosion control per proposed survey prior to
16 foundation inspection. Rock construction entrance and site perimeter controls such
as silt fence are required. Maintain erosion controls until landscaping is completed.
3 1 Page
PLAN
NO. DEPT SHEET/
SPEC.
SECTION
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
CODE
COMMENTS
SECTION
bldg Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend
up from the radon control system's collection point to a point terminating a
minimum of 12" above the roof. The vent pipe shall be located at least 10' away
from any window or other opening into the conditioned spaces of the building. Vent
pipes routed through unconditioned spaces shall be insulated with a minimum of R-4
insulation. Vent pipes within the conditioned envelope of the building shall not be
insulated.
bldg
R312.2 Window Fall Protection Required for all windows 6' above grade with sill height of
less than 24", maximum opening must be less than 4".
bldg WARNING: Call Before You Dig! Gopher State one 651-454-0002
bldg.
a
Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not
Exceed 3 Air Exchanges Per Hour.
bldg Flash between House and Stoop.
bldg R319.1 Install House Numbers: 4" minimum, visible from street.
bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber /
damper areas are exposed.
bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord.
bldg
R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic.
Close horizontal to vertical penetrations.
bldg
R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly
blocked and carried continuously to foundation.
bldg Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to
daylight; schedule 40 pipe required).
bldg R402.4.1.1 Hardboard Backer Required behind tub / shower.
bldg Seal and Secure Sump Pump Basket Cover.
bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces).
bldg
R405.2.3 Drain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install
flexible hose connection extending to drainage area away from the foundation wall. ;
bldg R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for
Subpart 6 future active radon ventilation system.
bldg Radon gas vent pipes shall be provided with space around the vent pipe for future fan
R 1303.2402
installation. The space required for the future fan installation shall be a minimum of
24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum
distance of 3 vertical feet.
bldg R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation.
bldg
R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss
manufacture.
bldg R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to
MN Res -Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation.
code
bldg
R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception:
Detached Accessory Buildings)
4 1 P a g e
PLAN
NO. DEPT SHEET/
SPEC.
SECTION
b1der
38
39 bldg
40 zoning
CODE
COMMENTS
SECTION
2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2°d course of
R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2
anchors per plate, 1 anchor within V of each end.
Exterior non -draining foundation insulation requirements: have a rigid, opaque, and
weather -resistant covering to prevent degradation of the insulation's thermal
R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation
and extend a minimum of 6" below grade. The insulation and protective covering
system shall be flashed in accordance with IRC section R703.8.
DRIVEWAY REQUIREMENTS:
R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to
a width Not to Exceed 28 Ft. and the Public Street.
5 1 Page
clrvFR
MonticelinBUILDINGCARQtY
APPROVED PILE Copy
REVIEWED FOR CODE COMPLIANCE
VQJE'CT TO FIE D INSPECTION
Date: j;
Signature; ifflof,
INDEX
SHEET TITLE
ITITLE SHEET
TYPICAL FRAMING DETAILS
ELEvATIONS d ROOD PLAN
ILOWER FLOOR PLAN
I MAIN FLOOR PLAN
I UPPER FLOOR PLAN
IELECTRICAL PLANS
IELECTRICAL PLANS
IINTERIOR ELEVATIONS/CABINETS
IBUILDING SECTIONS
IBUILDING: SECTIONS
IGENERAL NOTES
ITYPICAL WALL SECTIONS
ITYPICAL DETAILS
Jil'PICAL DETAILS
J
L1J
G
J
W
I
DRAWING RECORD
REVIEW SET 12-06.2024PERMITSET12-09.2024CLIENTSET
12.09.2024
SQUARE FOOTAGE
MAIN FLOOR FINISHED
UPPER FLOOR FINISHED
LOWER FLOOR FINISHED
TOTAL FINISHED
FOUNDATION
OVERALL SQUARE FEET
GARAGE
TITLE SHEET
xx
1056
1277
787
3120
1024
3357
700
low-nom
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Post:
panel. BrooksMailingAdressoftheDwellingorDwellingUnit
W11",
City
1
JP
MoYl3n l BUILDERS
Name of Residential Contractor MN License Number
JP Brooks Builders 686554
THERMAL ENVELOPE RADON CONTROL SYSTEM
I CITVQF Type: Check All That Apply X Passive (No Fan)
l4lont> cello
DUiLD;NG SAFETY
o c or other system monitoring
APPROVED FILE COPY o
FOR CODE COMPLIANCE
a a Location (or future location) of Fan:
Ziz -v;::',VED
T -, Ir rvSPECTION o
0 C 0 o 0- m Attic
Q 3 U o
J 0lat .901 B
0
Q m m a) -0 c
p to N O a) . U
Insulation Location ,Y o Z cNa cu U Q j Cn
m 0)
Ta 5
o E C,
c a) a)
uL zLL -- i Li iY Other Please Describe Here Below
Entire Slab Poly Barrier Foundation
Wall x x Exterior and Interior as dictated by code Perimeter
of Slab on Grade x Interior Foundation Wall Rim
Joist (1st Floor) x Rim
Joist (2nd Floor+) x Wall
x Ceiling,
flat x Ceiling,
vaulted x Bay
Windows or cantilevered areas x Floors
over unconditioned area Describe
other insulated areas Building
envelope air tightness: Duct system air tightness: Windows &
Doors Heating or Cooling Ducts Outside Conditioned Spaces Average
U-Factor (excludes skylights and one door) U: x Not applicable, all ducts located in conditioned space ffi
SolarHeatGainCoecient (SHGC): I IR-value MECHANICAL
SYSTEMS I Make-up Air Select Type Appliances
Heating System Domestic
Water Cooling
System x Heater
Not required per mech. code Fuel
Type Natural Gas Natural Gas Electric Passive Manufacturer
Bryant Richmond Bryant Powered Interlocked
with exhaust device. Model
915SBO4206OE17 BAC013NR030BNG Describe: Input
in 60,
000 CapacityT Output (INOther, describe: Rating
or Size BTUS: Gallons:50 in Tons: Ott 5 AFUE
or SEER Location of duct or system: Efficiency
HSPF% EER Heating
Loss Heating Gain Cooling Load Residential
Load Calculati q
1
C )"
1 cfm-s round
duct OR MECHANICAL
VENTILATION SYSTEM I metal duct Describe
any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source
heat pump with gas back-up furnace): Not required per mech. code Select
Type x Passive Heat
Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: x
Energy Recover Ventilator (ERV) Capacity in cfms: Low: I lHigh: I Location of duct or system: Balanced
Ventilation capacity in cfms: Location
of fan(s), describe: I Cfm's Capacity
continuous ventilation rate in cfms: 6 " round duct OR Total
ventilation (intermittent + continuous) rate in cfms: metal duct Builders
Associaton of Minnesota version 101014
Recher HVAC
HVAC Load Calculations
for
4462 86th Street
Prepared By:
Friday, December 6, 2024
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Project Report
General Project Information
Project Title: Recher HVAC
Project Date: Friday, December 6, 2024
Client Name: 4462 86th Street
de si n Data
f
Reference City: Minneapolis/St. Paul AP, Minnesota
Building Orientation: Front door faces East
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor
Dry Bulb Wet Bulb
Winter: -15 -15
Summer: 88 71
Outdoor Indoor
Rel.Hum
n/a
Rel.lum
n/a
44% 50%
Elite Software Development, Inc.
Recher HVAC
Page 2
Indoor Grains
Dry Bulb Difference
72 n/a
75 24
ECheck Figures
Total Building Supply CFM: 1,014 CFM Per Square ft.: 0.325
Square ft. of Room Area: 3,122 Square ft. Per Ton: 1,322
Volume (ft'): 20,529
Building Loads
Total Heating Required Including Ventilation Air: 54,709 Btuh 54.709 MBH
Total Sensible Gain: 23,857 Btuh 84 %
Total Latent Gain: 4,478 Btuh 16 %
Total Cooling Required Including Ventilation Air: 28,334 Btuh 2.36 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plvmouth. MN 55441
Miscellaneous Report
System 1 House
Input Data
Winter:
Summer:
Duct Sizing_ Inputs
Main Trunk
Calculate: Yes
Use Schedule: Yes
Roughness Factor: 0.00300
Pressure Drop: 0.1000 in.wg./10C
Minimum Velocity: 0 ft./min
Maximum Velocity: 900 ft./min
Minimum Height: 0 in.
Maximum Height: 0 in.
Outside Air Data
Outdoor Outdoor Outdoor
Drv_ Bulb Wet Bulb Rel.Hum
15 15 100%
88 71 44%
Runouts
Yes
Yes
0.01000
0.1000 in.wg./100 ft.
0 ft./min
750 ft./min
0 in.
0 in.
Winter
Infiltration Specified: 0.280 AC/hr
Infiltration Actual:
Above Grade Volume
96 CFM
0.280 AC/hr
X 20,529 Cu.ft.
5,748
X 0.0167
Cu.ft./hr
Summer
0.150 AC/hr
51 CFM
0.150 AC/h r
X 20,529 Cu.ft.
3,079
X 0.0167
Cu.ft./hr
Elite Software Development, Inc.
Recher HVAC
Page 3
Indoor Indoor Grains
Rel.Hum Drv_ Bulb Difference
n/a 72 n/a
50% 75 23.51
Total Building Infiltration: 96 CFM 51 CFM
Total Building Ventilation: 160 CFM 160 CFM
System 1---
Infiltration & Ventilation Sensible Gain Multiplier.- 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier.- 15.51 = (0.68 X 0.970 X 23.51 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.280 AC/hr (96 CFM), Construction: Average
Summer Infiltration Specified: 0.150 AC/hr (51 CFM), Construction- Average
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plymouth, MN 55441
Elite Software Development, Inc.
Recher HVAC
Page 4
Load Preview Report
Net ft.' Sen Lat Net Sen Hts9
s
Cl9 Sys
Act
Duc Scope
Ton lTon Area: Gain Gain Gain' Loss CFM CFM CFM Sid Building
2.36 1,322 3,122 23,857 4,478 28,334 54,709 533 1,014 1,014 Svstem
1 2.36 1,322 3,122 23,857 4,478 28,334 54,709 533 1,014 1,014 12x1f Ventilation
2,220 2,482 4,702 14,856 Zone
1 3,122 21,637 1,996 23,633 39,853 533 1,014 1,014 12x1 f 1-
Lower Level 789 3,789 245 4,034 8,206 110 178 178 2-- 2-
Main Level 1,056 8,052 392 8,444 15,635 209 377 377 4 3-
Upper Level 1,277 9,795 1,359 11,154 16,012 214 459 459 5- auerfiles\
FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steel (Plymouth) Recher HVAC
PI mouth MN 55441 Page 5
Duct Size Pre vie w
Room or
Source
Minimurr( Maximum Rough; Design SP, Duct_ Duct' Htg Gig Act. _ Duct
Duct Name Velocity Velocity Factor L/100 Loss` Velocity Length Flow ;_._Flow Flow Size
Svstem 1
Supply Runouts
Zone 1
1-Lower Level Built -In 0 750 0.01 0.1 452.1 110M 178 2--6
2-Main Level Built -In 0 750 0.01 0.1 480.3 209M 377 4--
3-Upper Level Built -In 0 750 0.01 0.1 467.4 214M 459 5--
Other Ducts in System 1
Supply Main Trunk Built -In 0 900 0.003 0.1 810.9 533 1,014 12x1
Summary
Svstem 1
Heating Flow: 533
Cooling Flow: 1014
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Elite Software Development, Inc.
Recher HVAC
Plymouth, MN 55441 Pa e 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
Marvin: Glazing -Marvin, U-value 0.34, SHGC 0.32 328.4 9,716 0 10,325 10,325
11P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292
15BO-10sf-8: Wall -Basement, , R-10 board insulation to 832 3,619 0 0 0
floor, no interior finish, 8' floor depth, U-value 0.05
15BO-10sf-4: Wall -Basement, , R-10 board insulation to 144 677 0 0 0
floor, no interior finish, 4' floor depth, U-value 0.054
12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 2185.6 12,360 0 1,890 1,890
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
1613-50: Roof/Ceiling-Under Attic with Insulation on Attic 1276.8 2,222 0 1,226 1,226
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
21 B-20: Floor -Basement, Concrete slab, any thickness, 2 788.8 1,304 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 20' wide, U-value 0.019
Subtotals for structure: 30,958 0 13,733 13,733
People: 6 1,200 1,380 2,580
Equipment: 0 3,600 3,600
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 96, Summer CFM: 51 8,895 796 712 1,508
Ventilation: Winter CFM: 160, Summer CFM: 160 14,856 2,482 2,220 4,702
Exhaust: Winter CFM: 160, Summer CFM: 160
AED Excursion: 0 0 2,212 2,212
Total Building Load Totals: 54,709 4,478 23,857 28,334
Check Figures
Total Building Supply CFM: 1,014 CFM Per Square ft.: 0.325
Square ft. of Room Area: 3,122 Square ft. Per Ton: 1,322
Volume (ft3): 20,529
Building Loads
Total Heating Required Including Ventilation Air: 54,709 Btuh 54.709 MBH
Total Sensible Gain: 23,857 Btuh 84
Total Latent Gain: 4,478 Btuh 16
Total Cooling Required Including Ventilation Air: 28,334 Btuh 2.36 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plvmouth. MN 55441
Buildinq Pie Chart
Wall 30%
Glass 36%
Floor 2%
Roof 4%
Glass 18%
Roof 4%
Wall 7%
Elite Software Development, Inc.
Recher HVAC
Page 71
Ventilation 27%
Infiltration 16%
Door 2%
AED Excursion 8%
Door 1% People 9%
Ventilation 17%
Infiltration 5%
Equipment 13%
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Elite Software Development, Inc.
Recher HVAC
Plymouth, MN 55441 Pa e 8
Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure_)
General
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 28.2 ft. System Number: 1
Room Width: 28.0 ft. Zone Number: 1
Area: 788.8 sq.ft. Supply Air: 178 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 1.7 AC/hr
Volume: 6,310 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 2 Actual Winter Vent.: 33 CFM
Runout Air: 89 CFM Percent of Supply.: 19
Runout Duct Size: 6 in. Actual Summer Vent.: 28 CFM
Runout Air Velocity: 452 ft./min. Percent of Supply: 16
Runout Air Velocity: 452 ft./min. Actual Winter Infil.: 5 CFM
Actual Loss: 0.128 in.wg./100 ft. Actual Summer Infil.: 3 CFM
Item Area -U- Htg Sen Clg Lat Sen
E -Wall-15BO-1 Osf-8 36 X 8 288 0.050 4.4 1,253 0.0 0 0
S -Wall-1 5BO-1 Osf-8 34 X 8 272 0.050 4.4 1,183 0.0 0 0
N -Wall-15BO-10sf-8 34 X 8 272 0.050 4.4 1,183 0.0 0 0
W -Wall-15BO-10sf-4 36 X 4 144 0.054 4.7 677 0.0 0 0
W -Wall-12F-Osw 36 X 4 90 0.065 5.7 509 0.9 0 78
W -GIs-Marvin shgc-0.32 0%S (3) 54 0.340 29.6 1,596 34.3 0 1,854
Floor-21 B-20 28 X 28.2 788.8 0.019 1.7 1.304 0.0 0 0
Subtotals for Structure: 7,705 0 1,932
Infil.: Win.: 5.4, Sum.: 2.9 144 3.479 501 0.278 45 40
AED Excursion: 387
People: 200 lat/per, 230 sen/per: 1 200 230
Equipment: 0 1,200
Room Totals: 8,206 245 3,789
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Elite Software Development, Inc.
Recher HVAC
Plvmouth. MN 55441 Page 9
FDetai1edRoomLoads-__Room 2 - Main Level (Average Load Procedure
General
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 33.0 ft. System Number: 1
Room Width: 32.0 ft. Zone Number: 1
Area: 1,056.0 sq.ft. Supply Air: 377 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr
Volume: 9,504 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 4 Actual Winter Vent.: 63 CFM
Runout Air: 94 CFM Percent of Supply.: 17 %
Runout Duct Size: 6 in. Actual Summer Vent.: 60 CFM
Runout Air Velocity: 480 ft./min. Percent of Supply: 16 %
Runout Air Velocity: 480 ft./min. Actual Winter Infil.: 47 CFM
Actual Loss: 0.144 in.wg./100 ft. Actual Summer Infil.: 25 CFM
Item Area U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
E -Wall-12F-Osw 36 X 9 252 0.065 5.7 1,425 0.9 0 218
S -Wall-12F-Osw 34 X 9 306 0.065 5.7 1,730 0.9 0 265
W -Wall-12F-Osw 36 X 9 228 0.065 5.7 1,289 0.9 0 197
N -Wall-12F-Osw 34 X 9 294 0.065 5.7 1,663 0.9 0 254
E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146
E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146
E -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,030
W -GIs-Marvin shgc-0.32 0%S 9 0.340 29.6 266 34.3 0 309
W -GIs-Marvin shgc-0.32 0%S 42 0.340 29.6 1,242 34.3 0 1,442
W -GIs-Marvin shgc-0.32 0%S (3) 45 0.340 29.6 1,332 34.3 0 1,545
N -GIs-Marvin shgc-0 32.1.00%%_ 12 _ 0 340 2.9 6 . 35.5 10.5 0 126_
Subtotals for Structure: 11,250 0 5,678
Infil.: Win.: 47.2, Sum.: 25.3 1,260 3.480 4,385 0.279 392 351
AED Excursion: 823
Equipment: 0 1,200
Room Totals: 15,635 392 8,052
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8.39 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steel (Plymouth) Recher HVAC
Plvmouth. MN 55441 Paae 10
LDe_t__a_iled___R_oom__ Loads - Room 3 -Upper Level (Average Load Procedurj
General
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 36.5 ft. System Number: 1
Room Width: 35.0 ft. Zone Number: 1
Area: 1,276.8 sq.ft. Supply Air: 459 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr
Volume: 10,214 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 5 Actual Winter Vent.: 64 CFM
Runout Air: 92 CFM Percent of Supply.: 14 %
Runout Duct Size: 6 in. Actual Summer Vent.: 72 CFM
Runout Air Velocity: 467 ft./min. Percent of Supply: 16 %
Runout Air Velocity: 467 ft./min. Actual Winter Infil.: 43 CFM
Actual Loss: 0.136 in.wg./100 ft. Actual Summer Infil.: 23 CFM
Item Area U- Htg Sen Clg Lat Sen
Description Quantitv Value HTM Loss HTM Gain Gain
E -Wall-12F-Osw 36 X 8 247.6 0.065 5.7 1,400 0.9 0 214
S -Wall-12F-Osw 36 X 8 268 0.065 5.7 1,516 0.9 0 232
W -Wall-12F-Osw 36 X 8 227 0.065 5.7 1,284 0.9 0 196
N -Wall-12F-Osw 36 X 8 273 0.065 5.7 1,544 0.9 0 236
E -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,030
E -GIs-Marvin shgc-0.32 0%S (2) 10.4 0.340 29.6 308 34.4 0 358
S -GIs-Marvin shgc-0.32 0%S 20 0.340 29.6 592 19.0 0 380
W -GIs-Marvin shgc-0.32 0%S 16 0.340 29.6 473 34.3 0 549
W -GIs-Marvin shgc-0.32 0%S (3) 45 0.340 29.6 1,332 34.3 0 1,545
N -GIs-Marvin shgc-0.32 100%S 15 0.340 29.6 444 10.5 0 157
UP-Ceil-16B-50 36.5 X 35 1276.8 0.020 1.7 2,222 1.0 0 1,226
Subtotals for Structure: 12,003 0 6,123
Infil.: Win.: 43.2, Sum.: 23.1 1,152 3.480 4,009 0.279 359 321
AED Excursion: 1,001
People: 200 lat/per, 230 sen/per: 5 1,000 1,150
Equipment: 0 1,200
Room Totals: 16,012 1,359 9,795
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Friday, December 6, 2024, 8:39 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plymouth, MN 55441
System 1 Room Load Summary
Htg Min Run Run Clg
Room
No
Area Sens Htg Duct Duct Sens
Name SF Btuh CFM Size Vel Btuh_
Zone 1---
1 Lower Level 789 8,206 110 2-6 452 3,789
2 Main Level 1,056 15,635 209 4-6 480 8,052
3 Upper Level 1,277 16,012 214 5-6 467 9,795
Ventilation 14,856 2,220
System 1 total 3,122 54,709 533 23,857
System 1 Main Trunk Size: 12x15 in.
Velocity: 811 ft./min
Loss per 100 ft.-. 0.099 in.wg
Cooling System Summary
Elite Software Development, Inc.
Recher HVAC
Page 1
Clg Min Act
Lat Clg Sys
Btuh CFM CFM
245 178 178
392 377 377
1,_359 459 459.
2,482
4,478 1,014 1,014.
Cooling Sensible/ Latent Sensible LdM1It ota
Tons Split _ Btuh _ Btuh _ Btuh
Net Required: 2.36 84% / 16% 23,857 4,478 28,334
Equipment Data
Cooling SystemHeatingS_
Type:
sytem
Natural Gas Furnace Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency: 0 AFUE 0 SEER
Sound: 0 0
Capacity: 0 Btuh 0 Btuh
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Friday, December 6, 2024, 8.39 AM
X 967.5 /
se
k
Drainage and Utility Easements are
shown thus:
L6
12
6
12
N.T.S.
Being 6 feet in width and adjoining lot
lines and 12 feet in width and adjoining
street lines and rear lot lines as shown
on this plat, unless otherwise shown.
r-ram r• .. i
155-264-0030/0 \
k Ede~ '1 ''` }i -• \
968 6-
24.0 'O 4 00, A96V -•'Q ?
O)
4x ?
1 967 84968,0
T9s Ir ° 06 Sp 6$ 0 \ 6S Ar ... w55
hProposed • 1 6X 1 967.8 ,o
Garage
A)
X 966 9 X 964.9 .1IP yip
i
o .S 96a.4 1 Opp 0 30
1 I 9 / 2.5'i 9 • S k 12 l
Prop d.
3 X 969. 0 _
j
fro ' '/o ? H 62+96
g
14 X961.
5 6k —
I--- • SCALE: I" 30'
Spa v` 1 jo' g69.3 ` I 965 8 6.51 ; 9 w
97a18 + \ .• / Tot g1•e
X
ti oa c 9 PROXCT BENCHMARK:
Top of hub w/tock at NW'ly buildingy
ArO 9682 `j'3 I comer offset
I- 7 L E/evotion - 968.79 feet (Plot Datum)
Cr Al ° PID: 15 264-0021 I A- UOkNsArea15,43/ S.F. ON A
c }
1
Y 4h
w
Certificate of Survey®
ford! h
ono oJPBrooksBuildersac, b
Lot 13, Block 2, EDMONSON RIDGE
Cit of Monticello, Wightht County, Minnesota
Adlafraeel: 4462 86TH STREET ALE AkInd eft MN 65W2
NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL
THIS PLAN IS APPROVED BY THE LOCAL BUILDING
INSPECTOR
LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS.
BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT.
EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS
PROVIDED TO US.
CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE.
THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE
SEWER SERVICE.
PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND
BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S).
STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN.
UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS
DATED 7/29/2021, PAGES 22-24, BY ALLIANT ENGINEERING.
OFFSETS LEGEND:
O(eM)
OS,/'2 967.84 O Denotes set iron monument
OS,/'3 = 967.76 Denotes set hub
0S#4 = 970.I8
Denotes set lath
x 976.4 Denotes existing ground elevation
Denotes found iron monument
942.. Denotes proposed elevation
Denotes proposed drainage flow
Denotes electric service
T Denotes telephone pedestal
Denotes cable television box
FO Denotes fiber optic service box
Denotes water service (per plan)
Denotes sanitary service (per plan)
Denotes sanitary manhole (per plan)
H Denotes watervolve (per plan)
Denotes hydrant (per plan)
i
Denotes bituminous surface (per plan)
Denotes easement
960 Denotes contour per grading plan
Denotes sanitary sewer (per plan)
Denotes waterline (per plan)
g68 5
CS 3 `
9s) 0.35% Ac.)
I
o ` SETBACKS HOUSE TYPE
677F{j Landscape / / \ j (' ,
7'
Front Lu BuutementVVV7' SideEdge
I A- 30' Rear rt
House 90 \ 3 & 20' Side Street P.U.D.
458 Mow Lin
g1 i I dh • nn `` DR/ VEWAY AREA TD STREET: i4 /
ry \ !'_ , I m I, 934 V S. F.
b / + ,o o I 4'rj I I ,SOO AREA,
o O O 0 1 Full Yob - 14,85/7c S.F.
i i \
a) O °
I k
i 30' Behind House - 7,334% SF.
PID: 155-264-002120 I h y PROPOSED IMPERVIOUS Sll?FACES
o, I Total lot Area - 15,431!4 S.F.
House Area = 1, 825Y- S. F.
0 / 1z DrivewQZ/Wdk Area = 736 .SF.
0* Total impervious Area = 2,56/4 S.F. (16.5X)
ELEV PER GRADING PLAN
r. , r,
l
r Pions by Alliant.
Garage Floor Elev - 97L 0
Lowest Floor Elevation = 964.0
12 155 Rear Elevation = 968.0
6 J L - Lookout
96 I REFERENCE BENCHMARK,•
T er Rim of sanitary manhole on 86th St.
NE near West plot boundary.
r% i r. .. r- \ PCu' Elevation = 957.15 feet (Plot Datum)
PROPM DING SURVEY - /P y:• I PROPOSED HOUSE ELEVA LIONS
Open
Top of Foundation Elev = 972.7 (H
Approved Date 12/23/2024 / I Top of Foundation Elev = 97L 7 (Garage)
Garage Floor E/ev = 97L4
L t F/ El — 964 7
House)
SHEET NO.
I Certificate of Survey BOGART, PEDERSON
JP Brooks Builders & ASSOCIATES, INC.
L139 B2, EDMONSON RIDGE CIVIL
D SURVEYING
ENGINEERING
NG
Wright County, Minnesota 3076IFI FIRST STREET, BECKER, MN 55308-9322
TEL: 763-262-8822 FAX: 763-262-8844
owes Oor ev —
Lowest Opening Elev = 967.9
1 hereby certify that this survey, plan, or
report was prepared by me or under my DATE: 12/ 10/24
my direct supervision, and that I am a
duly Licensed Land Surveyor under the DESIGN BY:
laws of the State of Minnesota. DRAWN BY: ZH
CHECKED BY:CAW
DWG FILE: L13 B2 HS
g A. Wensmann FILE NO.:
Date: 12/13/24 Reg. No.47466
REV
NO. DATE DESCRIPTION