Loading...
2024-00494CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 4472 86TH ST NE PIN 155264002003 LEGAL DESC EDMONSON RIDGE LOT 002 BLOCK 003 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION S 324,157.42 NOTE: NEVI' CONSTRUCTION SINGLE FAMILY HOME 690 SQ FT FINISHED BASEMENT 233 SQ FT UNFINISHED BASEMENT 857 SQ FT FINISHED MAIN FLOOR 84 SQ FT OPEN PORCH 719 SQ FT GARAGE A,'C YES HVAC WATER METER 1 (MAIN) 1.00 SAC UNITS WAC UNITS 1.00 r:muf1`.nulr JP BROOKS }TOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55369- 763) 999-7 153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicantf v% Date 4; Bldg Official Date v 2 0 2 4- 0 0 4 9 4 DATE ISSUED: 06/25/2024 Permit #: 2024-00494 BUILDING PERMIT FEE 2,389.88 PLAN REVIEW 1,553.42 STATE SURCHARGE, BLDG VAL 162.08 SAC FEE 30% 1,407.60 SAC FEE 70% 3,284.40 WATER ACCESS CHARGE, REST 2.090.00 COMB CONNECTION FEE /RESI 130.00 SEWER / WATER EXCAVATION PERMIT 130.00 CONTRACTOR LICENSE VERIFICATION FEE 5.00 ASSESSMENT SEARCH FEE 50.00 UTILITY LOCATE FEE, RESI 50.00 WATER METER 1 (MAIN) 412.00 MN STATE SALES TAX (MTR 1) 30.39 TOTAL 11,694.77 Payment(s) CHECK 20730 11,694.77 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. V \ CITY OF Monticeffo BUILDING SAFETY a- PERMIT 505 WALNUT STREET, SUITE 1 MONTICELLO, MN 55362 City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED..2k4/-6V aj_ 5 SITE ADDRESS: `ALA-j cl &0 " Srtk;f J , ZONED LEGAL: Lot A Block 3 Plat F-Cl"an-5ovi AjCit Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders Phone: 763-285-4790 State License #: 656554 E-Mail: shelly@jpbrooks.com Address: 13700 Reimer Drive City: Maple Grove State: MN Zip: 55311 Eng./Architect Name: Address: Plumber Name: Northwoods Plumbing Address: 30799 73rd Street Mechanical Name: Recher HVAC Address: 1125 Mississippi Drive North Twe of Work A New Addition Alteration Repair Move Other Description of work: Phone: City: State: Zip: Phone: 763-717-8757 City: Pierz City: Champlin Tvae of Construction X Single Family Duplex Multi -Family Commercial Industrial Other State: MN Zip: 56364 Phone: 612-802-6525 State: MN Zip: 55316 Building information Use of building of stories Floor area sq. ft. Z)Q>il-'A, si.,_%,IPe-,L, Estimated value _ of construction $ d 5 Z - At 2. I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE BACK FOR PLUMBING AND MECHANICAL INFO. Applicant Si ture Application Date 41' - 17- APPLICANT: Please show fixtures that are applicable. Fire Suppression : (if applicable) Plumbing: (if applicable) Mechanical: (if applicable) No. Fixture Tvne No, Fixture Tvue No. Fixture Tvae Sprinkler Heads Ll Water Closet (toilet) J— Furnace Other /Special FS Device 3 Bathtub Gas Meter Lavatory (wash basin) Range Hood Shower Gas Range Kitchen Sink Water Heater 1 Dishwasher Air Conditioning 1 Laundry Tub 1 Mech. Fireplace Clothes Washer Bathrooms) Exhaust Fan Fire Alarm: (if applicable)— Water Heater Air Exchanger Urinal Dryer No. Fixture Tvne Drinking Fountain Gas Opening w/o Fixture Floor Drain of Devices Slop Sink Other Outside Faucet 10 TOTAL_ TOTAL Future Owner Information: Name: Address: FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No City: ADDITIONAL INFORMATION: Valuation: 32-4. 1 5 7 Y 2- State: Zip: Construction Type: v - t3 Occupancy Group: V /Z(- 1 Phone #: Division: Square Footage: of Stories: 2-r—r" 'W- J{L '%W7 of Residential Units: ) - )0 Wt e— Maximum Occupancy: Ao A Fire Sprinklers: Yes 59 No Off -Street Parking Covered: 3 Off -Street Parking Uncovered: 3 uilding Official BPT: / / IT Y ()F Monticello 2024 Residential Building Permit Calculator Address: 4472 861h SINE Legal: 1 = Yes 0 = No New Residence: I House Type: 2 story, Walk Out 1 = Yes 0 = No 1 = Yes 0 = No Permit Applicant: Contractor: 1 Plan Review: I JP Brooks Owner- 0 Master Plan: 0 Master Plan Review = 25% of Building Permit Fee) Crawl Space 0 $ 15.27 Unfinished Basement Area 233 $ 16.50 3,844.50 Finished Basement Area 690 $ 44.05 30,394.50 Main/First Floor Area 857 $ 125.00 107,125.00 Second Floor Area 1,267 $ 115.00 145,705.00 Detached Garage 0 $ 60.00 Attached Garage 718 $ 47.33 33.982.94 Garage Conversion to Living Space 0 $ 47.44 Carport/Gazebo 0 $ 30.90 Pole Barn 0 $ 19.03 Shed - greater than 200 SF 0 $ 40.00 Lean -to -Shed 0 $ 13.25 Basement Finish Only 0 $ 16.00 Remodeled Area 0 $ 17.39 Porch (open) 84 $ 36.97 3.105 48 Porch (3-Season) 0 $ 60.00 Porch (3-Season on Existing Deck) 0 $ 55.00 Porch (Screen Porch/Breezeway) 0 $ 58.48 Solarium 0 $ 94.90 Deck 0 $ 20.00 Deck (Screen In & Roof Over Existing) 0 $ 29.80 In -Ground Pool 0 $ 23.18 Above -Ground Pool 0 $ 11.31 Fireplace - Mechanical/Gas 0 $ 4.892.50 Fireplace - Masonry 0 $ 22,660.00 Elevator/Lift/Other 0 CALCULATED BUILDING VALUATION S 324,157.42 1 =Yes O=No Water Hook-up 1 Sanitary Sewer Hook-up 1 ti FEES: BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,388.98 PLAN CHECK 1,552.83 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 162.08 SUBTOTAL 4,108.89 SEWER FEE [SAC] 4,692.00 WATER FEE ]WAC] 2,090.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 50.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 442.69 SUBTOTAL 7,584.69 TOTAL FEES CALCULATED 11,693.58 Escrow Amount - (Winter Only) TOTAL AMOUNT TO BE PAID TO CITY 11,693.58 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution I Date Certificate Posl panel. Mailing Address of the Dwelling or Dwelling Unit Name of Residential Contractor JP Brooks Builders THERMAL ENVELOPE Insulation Location Below Entire Slab Foundation Wall Perimeter of Slab on Grade If Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors Average U-Factor (excludes skylights and one door) U Solar Heat Gain Coefficient (SHGC): MECHANICAL SYSTEMS Appliances Heating System Fuel Type Nat. Gas 0 N a IT ro 0 a ro c OY om ro Q N NA R-15 R-15 R-30 R-30 R-21 R48 R-48 R-30 NA City MN License Number BC 686554 Place your logo here RADON CONTROL SYSTEM Type: Check All That Apply I FV_j Passive (No Fan) Active (With fan and monometer roa CoU 3 roQ0 .. Q m m ZU Cnroro o m rn o m a Z LL ii. I 1 C or other system monitoring device) y Location (or future location) of Fan: T ao Attic a m 2 T 00 W w o :o of it Other Please Describe Here Poly Barrier Exterior and Interior as dictated by code Interior of foundation wall Duct system air tightness: I NA IlHeating or Cooling Ducts Outside Conditioned Spaces Its I QNot applicable, all ducts located in conditioned space 28 III 1 R-value Domestic Water Heater Nat. Gas Manufacturer Bryant Richmond 1915SB042060E17 IModel Input in Capacity Rating or Size IBTus: 60,000 Iin Gallons: 5 IHSPF%r 96.2 190Efficiency Heating Loss I Heating Gain Residential Load Calculat' 1 MECHANICAL VENTILATION SYSTEM I Make-up Air Select a Type Cooling System I RI Not required per meth. code Elect. I Passive IBryant II IPowered BA013NR030BNG II I Interlocked with exhaust device. Describe: OutputIin I I Other, describe: Tons: C SEER 13 I Location of duct or system: 1EER Cooling Load a5,3 1 , II Cfm's round duct OR II " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two fumaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): n Not required per mech. code Select Type IHeatRecoverVentilator (HRV) Capacity in cfrns: Low: I High: F110therPassivedescribe: Energy Recover Ventilator (ERV) Capacity in cfms: Balanced Ventilation capacity in cfms: Low: 190 High: ' 130 I Location of duct or system: I Mechanical Room Location of fan(s), describe: I Bathrooms and Laundry II Cfm's Capacity continuous ventilation rate in cfms: 1 so -130 11 s round duct OR Total ventilation (intermittent + continuous) rate in cfms: 1270 II metal duct Builders Associaton of Minnesota version 101014 Reacher HVAC HVAC Load Calculations for 4472 86th Street NE Prepared By: Tuesday, May 14, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Proiect Report General Proiect Information Project Title: Project Date: Client Name: Desion Data Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Reacher HVAC Tuesday, May 14, 2024 4472 86th Street NE Outdoor D[y Bulb Winter: -15 Summer: 88 Check Fioures St. Cloud AP, Minnesota Front door faces East Medium 45 Degrees 1024 ft. 0.964 Outdoor Outdoor Indoor Indoor Wet Bulb Rel.Hum Rel.Hum DryBulb 15 n/a n/a 72 71 44% 50% 75 Elite Software Development, Inc. Reacher HVAC Paae 2 Grains Difference n/a 24 Total Building Supply CFM: 948 CFM Per Square ft.: 0.337 Square ft. of Room Area: 2,814 Square ft. Per Ton: 1,334 Volume (ft'): 19,987 Buildina Loads Total Heating Required Including Ventilation Air: 44,409 Btuh 44.409 MBH Total Sensible Gain: 20,930 Btuh 83 % Total Latent Gain: 4,381 Btuh 17 % Total Cooling Required Including Ventilation Air: 25,311 Btuh 2.11 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Miscellaneous Report System 1 House Input Data Winter: Summer: Duct Sizino Inputs Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Outside Air Data Infiltration Specified: Infiltration Actual: Above Grade Volume Total Building Infiltration: Total Building Ventilation: Elite Software Development, Inc. Reacher HVAC Pane 3 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference 15 -15 100% n/a 72 n/a 88 71 44% 50% 75 23.88 Main Trunk Yes Yes 0.00300 0.1000 in.wg./100 ft. 0 ft./min 900 ft./min 0 in. 0 in. Winter 0.320 AC/hr 107 CFM 0.320 AC/hr X 19,987 Cu.ft. X 6,396 0.0167 Cu.ft./hr 107 CFM 150 CFM Runouts Yes Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min 0 in. 0 in. Summer 0.160 AC/hr 53 CFM 0.160 AC/hr X 19.987 Cu.ft. 3,198 X 0.0167 Cu.ft./hr 53 CFM 150 CFM System 1-- Infiltration & Ventilation Sensible Gain Multiplier: 13.78 = (1.10 X 0.964 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.64 = (0.68 X 0.964 X 23.88 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.21 = (1.10 X 0.964 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr (107 CFM), Construction: Average Summer Infiltration Specified: 0.160 AC/hr (53 CFM), Construction: Average C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Reacher HVAC Plvmouth. MN 55441 Paae 4 Load Preview Report I Ne ft Se La Ne Sen Ht CI A Dud Scope To To Are Gal Gai Gai Loss) CFM CFM CFM Size Buildino 2.11 1,334 2,814 20,930 4,381 25,311 44,409 524 948 948 Svstem 1 2.11 1,334 2,814 20,930 4,381 25.311 44,409 524 948 948 12x1e Ventilation 827 2,347 3,173 5,533 Zone 1 2,814 20,103 2,034 22,137 38,876 524 948 948 12xV 1-Lower Level 690 4,132 320 4,452 9,616 130 195 195 2—E 2-Main Level 857 6,660 350 7,010 13,660 184 314 314 3-7 3-Upper Level 1,267 9,311 1,364 10,675 15,600 210 439 439 4-7 C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plvmouth) Reacher HVAC Plvmouth. MN 55441 Pao_e 5 Duct Size Preview Room or Source Minimu Maximu Rough Desig SP Duc Duct Htg Clg Act. Duct Duct Name Veloc- Veloci Facto U10 Loss Veloc' Leng Flow I Flow I Flow Si7e__ Svstem 1 Supply Runouts Zone 1 1-Lower Level Built -In 0 750 0.01 2-Main Level Built -In 0 750 0.01 3-Upper Level Built -In 0 750 0.01 Other Ducts in System 1 Supplv Main Trunk Built -In 0 900 0.003 Summary Svstem 1 Heatina Flow: 524 Coolino Flow: 948 0.1 496.4 130 19 195 2-6. 0.1 391.8 184 r3lj 314 3-7 0.1 410.9 210 F 43 439 4-7 0.1 812.9 524 94 948 12xV C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Total Buildin_q Summary Loads Component Description Marvin: Glazing -Marvin, U-value 0.34, SHGC 0.32 11 P: Door -Metal - Polyurethane Core, U-value 0.29 15BO-10sf-8: Wall -Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 15BO-10sf-4: Wall -Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 166-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21 B-20: Floor -Basement, Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20'_wide U-value 0.019 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 107, Summer CFM: 53 Ventilation: Winter CFM: 150, Summer CFM: 150 Exhaust: Winter CFM: 150, Summer CFM: 150 AED Excursion:_ Total Building Load Totals: Check Fiaures Total Building Supply CFM: 948 Square ft. of Room Area: 2,814 Volume (ft'): 19,987 Buildina Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Elite Software Development, Inc. Reacher HVAC Paae 6 Area Sen Lat Sen Total Quan Loss Gain Gain Gain 241.2 7,139 0 8,269 8,269 42 1,060 0 292 292 540 2,520 0 46 46 340 1,768 0 52 52 2336.8 13,214 0 2,021 2,021 1267 2,205 0 1,216 1,216 689.8 1,140 0 0 0 29,046 0 11,896 11,896 6 1,200 1,380 2,580 0 3,600 3,600 0 0 0 0 0 0 0 9,830 834 735 1,569 5,533 2,347 827 3,173 0 0 2,492 2,492 44,409 4,381 20,930 25,311 CFM Per Square ft.: 0.337 Square ft. Per Ton: 1,334 44,409 Btuh 44.409 MBH 20,930 Btuh 83 % 4,381 Btuh 17 % 25,311 Btuh 2.11 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Buildinq Pie Chart Wall 39% Glass 33% Floor 3% Roof 5% Roof 5% Wall 8% Elite Software Development, Inc. Reacher HVAC Pane 7 Ventilation 12% Infiltration 22% Door 2% Glass 16% AED Excursion 10% Door 1 % People 10% Ventilation 13% Infiltration 6% Equipment 14% C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential r& Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Reacher HVAC Plvmouth. MN 5W1 Paoe 8 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure_) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 26.5 ft. System Number: 1 Room Width: 26.0 ft. Zone Number: 1 Area: 689.8 sq.ft. Supply Air: 195 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.9 AC/hr Volume: 6,208 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 37 CFM Runout Air: 97 CFM Percent of Supply.: 19 % Runout Duct Size: 6 in. Actual Summer Vent.: 31 CFM Runout Air Velocity: 496 ft./min. Percent of Supply: 16 % Runout Air Velocity: 496 ft./min. Actual Winter Infil.: 15 CFM Actual Loss: 0.153 in.wg./100 ft. Actual Summer Infil.: 8 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantitv Value HTM Loss HTM Gain Gain E -Wall-15BO-10sf-8 36 X 9 324 0.050 4.7 1,512 0.1 0 28 S -Wall-15BO-10sf-8 12 X 9 108 0.050 4.7 504 0.1 0 9 S -Wall-15BO-10sf-4 16 X 5 80 0.054 5.2 416 0.2 0 12 S -Wall-12F-Osw 16 X 4 64 0.065 5.7 362 0.9 0 55 W -Wall-15BO-1 Osf-4 36 X 5 180 0.054 5.2 936 0.2 0 28 W -Wall-12F-Osw 35 X 4 87.5 0.065 5.7 495 0.9 0 76 N -Wall-15BO-1 Osf-4 16 X 5 80 0.054 5.2 416 0.2 0 12 N -Wall-12F-Osw 16 X 4 64 0.065 5.7 362 0.9 0 55 N -Wall-I5BO-1 Osf-8 12 X 9 108 0.050 4.7 504 0.1 0 9 W -GIs-Marvin shgc-0.32 0%S (3) 52.5 0.340 29.6 1,554 34.3 0 1,800 Floor-21B-20 26 X_26.5 - - - 689.8 0.019_ 1.7- _-_1,140 _- 0.0 0 _ - 0 Subtotals for Structure: 8,201 0 2,084 Infil.: Win.: 15.3, Sum.: 7.7 395 3.579 1,415 0.268 120 106 AED Excursion: 512 People: 200 lat/per, 230 sen/per: 1 200 230 EgOpment: -- - - 0 1 200 Room Totals: 9,616 320 4,132 C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads y , Elite Software Development, Inc. Auer Steel (Plymouth) 5 I Reacher HVAC Plvmouth. MN 5W1 lJf Paae 9 Detailed Room Loads - Room 2 - Main Level (Avera_pe Load Procedure_) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 29.6 ft. System Number: 1 Room Width: 29.0 ft. Zone Number: 1 Area: 857.0 sq.ft. Supply Air: 314 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 7,713 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 53 CFM Runout Air: 105 CFM Percent of Supply.: 17 Runout Duct Size: 7 in. Actual Summer Vent.: 50 CFM Runout Air Velocity: 392 ft./min. Percent of Supply: 16 Runout Air Velocity: 392 ft./min. Actual Winter Infil.: 45 CFM Actual Loss: 0.077 in.wg./100 ft. Actual Summer Infil.: 22 CFM Item Area U- Htg Sen Cig Lat Sen Description Quantitv Value HTM Loss HTM Gain Gain E -Wall-12F-Osw 36 X 9 276 0.065 5.7 1,561 0.9 0 239 S -Wall-12F-Osw 28 X 9 252 0.065 5.7 1,425 0.9 0 218 W -Wall-12F-Osw 36 X 9 238 0.065 5.7 1,346 0.9 0 206 N -Wall-12F-Osw 28 X 9 252 0.065 5.7 1,425 0.9 0 218 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -GIs-Marvin shgc-0.32 0%S 6 0.340 29.6 177 34.3 0 206 W -GIs-Marvin shgc-0.32 0%S (2) 35 0.340 29.6 1,036 34.3 0 1,200 W -GIs-Marvin shgc-0.32 0%S 42 0.340 29.6 1,242 34.3 0 1,439 W —GIs-Marvin shac-0.32 0%S 9 0.340 29.6 266 34.2 0_ 308_ Subtotals for Structure: 9,538 0 4,326 Infil.: Win.: 44.7, Sum.: 22.3 1,152 3.578 4,122 0.267 350 308 AED Excursion: 826 Equipment; 0 1,200 Room Totals: 13,660 350 6,660 C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Reacher HVAC Plvmouth. MN 55441 Paqe 10 Detailed Room Loads - Room 3 - Upper Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 36.2 ft. System Number: 1 Room Width: 35.0 ft. Zone Number: 1 Area: 1,267.0 sq.ft. Supply Air: 439 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 10,136 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 60 CFM Runout Air: 110 CFM Percent of Supply.: 14 % Runout Duct Size: 7 in. Actual Summer Vent.: 69 CFM Runout Air Velocity: 411 ft./min. Percent of Supply: 16 % Runout Air Velocity: 411 ft./min. Actual Winter Infil.: 47 CFM Actual Loss: 0.085 in.wg./100 ft. Actual Summer Infil.: 23 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantitv Value HTM Loss HTM Gain Gain E -Wall-12F-Osw 36 X 8 244.2 0.065 5.7 1,381 0.9 0 211 S -Wall-12F-Osw 39 X 8 312 0.065 5.7 1,764 0.9 0 270 W -Wall-12F-Osw 36 X 8 235 0.065 5.7 1,329 0.9 0 203 N -Wall-12F-Osw 39 X 8 312 0.065 5.7 1,764 0.9 0 270 E -GIs-Marvin shgc-0.32 0%S (2) 35 0.340 29.6 1,036 34.3 0 1,200 E -GIs-Marvin shgc-0.32 0%S 8.8 0.340 29.6 259 34.3 0 300 W -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,028 W -GIs-Marvin shgc-0.32 0%S 8 0.340 29.6 237 34.3 0 274 W -GIs-Marvin shgc-0.32 0%S 15 0.340 29.6 444 34.3 0 514 UP-Ceil-16B-50 36.2 X 35 1267 0.020 1.7 2,205 1.0 0 1,216 Subtotals for Structure: 11,307 0 5,486 Infil.: Win.: 46.6, Sum.: 23.3 1,200 3.578 4,293 0.268 364 321 AED Excursion: 1,154 People: 200 lat/per, 230 sen/per: 5 1,000 1,150 Equipment: 0 1,200 Room Totals: 15,600 1,364 9,311 C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Reacher HVAC Plvmouth. MN 55441 Paae 11 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Gig Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM Zone 1--- 1 Lower Level 690 9,616 130 2-6 496 4,132 320 195 195 2 Main Level 857 13,660 184 3-7 392 6,660 350 314 314 3 Upper Level__ __.. 1267 15,600 210___.__4-7___411 9,311 1,364 439 439 Ventilation 5,533 827 2,347 Svstem 1 total 2,814 44,409 524 20,930 4,381 948 948 System 1 Main Trunk Size: 12x14 in. Velocity: 813 ft./min Loss per 100 ft.: 0.103 in.wg Coolina Svstem Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.11 83% / 17% 20,930 4,381 25,311 Ea_uioment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\sam.olson\Documents\Load Calcs\Recher HVAC 4472 86th Street NE.rh9 Tuesday, May 14, 2024, 8:50 AM x.1 GYNI s re APPROVED FILE CpPV c REVIEWED FOR CODE COMPOANCE o SUBIECT TO FIELD INSPECTION j Z Date. signature: 5HEET INDEX 5 4EET TITLE TITLE SHEET TYPICAL FRAMING DETAILS GENERAL NOTES ELEVATIONS & ROOF PLAN LOUDER FLOOR PLAN MAIN FLOOR PLAN UPPER FLOOR PLAN ELECTRICAL PLANS ELECTRICAL PLANS INTERIOR ELEVATIONS BUILDING SECTIONS BUILDING SECTIONS TYPICAL WALL SECTIONS TYPICAL DETAILS TYPICAL DETAILS L.A-J ow N 00 Q W UOoF- Uj z O i c h DRAWING RECORD REVIEW SET 05.10.2024 PERMIT SET 05.30.2024 SQUARE FOOTAGE MAIN FLOOR FINISHED 857 UPPER FLOOR FINISHED 1267 LOWER FLOOR FINISHED 690 TOTAL FINISHED 2814 FOUNDATION 857 OVERALL SQUARE FEET 2970 GARAGE 718 TITLE SHEET