Loading...
2026-00553CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 295-30bU YAX: (763) 295-4404 2 0 2 6— 0 0 S S 3 DATE ISSUED: 07/20/2026 Permit #: 2026-00553 ADDRESS : 4479 86TH ST NE PIN : 155264004120 LEGAL DESC EDMONSON RIDGE LOT 012 BLOCK 004 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION $ 345,005.22 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: SLAB u GRADE 0 SQ FT FINISHED BASEMENT 0 SQ FT UNFINISHED BASEMENT 1.073 SQ FT FINISHED MAIN FLOOR 1.381 SQ FT FINISHED SECOND FLOOR 60 SQ FT OPEN PORCH 707 SQ FT GARAGE FIREPLACE: YES -ELECTRIC A/C: YES MECHANICAL: 9 PLUMBING: 17 WATER METER 1 (MAIN) 1.00 SAC UNITS 1,00 WAC UNITS 1.00 APPLICANT BUILDING PERMIT FEE PLAN REVIEW 2,514.62 1,634.50 JP BROOKS HOMES STATE SURCHARGE, BLDG VAL 172.50 13700 REIMER DRIVE SUITE 100 SAC FEE 30% 1,507.80 MAPLE GROVE, MN 55311- SAC FEE 70% 3,518.20 763) 999-7153 WATER ACCESS CHARGE, RESI 2,732.00 COMB CONNECTION FEE / RESI 130.00 SEWER / WATER EXCAVATION PERMIT CONTRACTOR LICENSE VERIFICATION FEE 130.00 5.00 OWNER LSW INVESTMENTS LLC ASSESSMENT SEARCH FEE 60.00 4065 CHELSEA RD W UTILITY LOCATE FEE, RESI 50.00 MONTICELLO, MN 55362- WATER METER 1 (MAIN) 520.00 MN STATE SALES TAX (MTR1) 40.95 TOTAL Payment(s) 13,015.57 AGREEMENT AND SWORN STATEMENT CHECK 25569 13,015.57 1 agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. MZ05 111-- fllll? Applicant Date Bldg Official Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE:. CITY OF Monticello BUILDING SAFETY 505 WALNUT STREET, SUITE 1 City Hall (763) 295-2711 flVL r I i t J U L 6 2026 NTICELLO. MN 55362 ZO2005 s3 PERMIT # 3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: %1j 5 1+ ZONED LEGAL: Lot 12 Block L Plat (2, 49 Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City; Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders Phone: 763-285-4790 State License #: 656554 E-Mail: shelly@jpbrooks.com Address: 13700 Reimer Drive City; Maple Grove State: MN Zip: 55311 EngJArchitect Name: Phone: Address: City: State: Zip: Plumber Name: Northwoods Plumbing Phone: 763-717-8757 Address: 30799 73rd Street City: Pierz State: MN Zip: 56364 Mechanical Name: Recher HVAC Phone: 612-802-6525 Address: 1125 Mississippi Drive North City: Champlin State: MN Zip: 55316 Tyne of Work TXpe of Construction Building Information New IX Single Family Use of building 425; ey,e e, 1 -;-r— Addition Duplex of stories -rwe Alteration 0 Multi -Family Floor area sq. ft. 2-gSy P,:.s4d Repair Commercial Estimated value Move Industrial of construction $ zji9 Other Other 3L/Soc)S Ze-7 Description of work: hjir- ( 10-; ly 5 lti Gv- 9y-C',f. 4wC) 5 fury t1",e w I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Aq/ G— Applicant Signature Application Date SEE BACK FOR PLUMBING AND MECHANICAL INFO. 6, 015, 57 APPLICANT. Please showfixtures that are applicable. Fire Suppression : (if applicable) Plumbing: (if applicable) Mechanical. (if applicable) No. Fixture Type No. Fixture Tyne No. Fixture Type Sprinkler Heads Water Closet (toilet) Furnace Other / SpecialFS Device Bathtub i Gas Meter j Lavatory (wash basin) 6 Range Hood Shower I _ Gas Range I Kitchen Sink U Water Heater Dishwasher Air Conditioning d Laundry Tub 0 _ Mech. Fireplace P eGtY L I Clothes Washer Water Heater 3 I Bathroom( s) Exhaust Fan Air Exchanger FireAlarm: (if applicable) b Urinal Dryer No. Fixture Tyne 0 Drinking Fountain 0 Gas Opening w/o Fixture 1 Floor Drain L # of Devices O _ Slop Sink Other 2 _ Outside Faucet TOTAL TOTAL Future Owner Information: Address: City: State: Zip: Phone #: FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No onstruction Type: V-%3 Iccupancy Group: A: livision: & Dyt/17 Q1 quare Footage: Z y5q of Stories: 77-Tw of Residential Units: One- laximum Occupancy: f- ire Sprinklers: Yes 16 No ff- Street Parking Covered: K ff- Street Parking Uncovered: 13 Building Official PT: / / CITY OF jaMonticello 2026 Residential Building Permit Calculator Address: 4479 86th St NE Monticello MN Legal: Lot 12 Block 4 Edmonson Ridge I = Yes 0 = No New Residence: I House Type: Two story slab on grade 1 = Yes 0 = No 1 = Yes 0 = No Permit Applicant: Contractor: I Plan Review: I Owner: 0 Master Plan: 0 Master Plan Review = 25% ofBudding Permit Fee) Crawl Space 1,073 $ 15.27 16,384.71 Unfinished Basement Area 0 $ 16.3a Finkhad Basement P,rca 0 5 44.05 Main/First Floor Area 1,073 $ Aft$ 134,125.00 Second Floor Area 1,381 $ 115.00 158,815.00 Detached Garage 0 $ 60.00 Attached Garage 707 EL_ 47.33 33,462.31 Garage Conversion to Living Space 0 $ 47.44 Carport/Gazebo 0 $ 30.90 Pole Bam 0 $ 19.03 Shed - greater than 200 SF 0 $ 40.00 Lean -to -Shed 0 $ 13.25 Basement Finish Only 0 $ 16.00 Remodeled Area 0 $ 17.39 Porch (open) 60 $ 36.97 2,218.20 Porch (3-Season) 0 $ 60.00 Porch (3-Season on Existing Deck) 0 $ 55.00 Porch (Screen Porcb/Breezeway) 0 $ 58.48 Solarium 0 $ 94.90 Deck 0 $ 20.00 Deck (Screen In & Roof Over Existing) 0 $ 29.80 In -Ground Pool 0 $ 23.18 Above -Ground Pool 0 $ 11.31 Fireplace - Mechanical/Gas 0 $ 4,892.50 Fireplace - Masonry 0 $ 22,660.00 Elevator/Lift/Otber 0 CALCULATED BUILDING VALUATION $ 345,005.22 1 = Yes 0 = No Water Hook-up I Sanitary Sewer Hook-un 1 FEES: BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% $ 2,513.63 PLAN CHECK 1,633.86 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 172.50 SUBTOTAL 324.99 SEWER FEE [SAC] 5,026.00 WATER FEE ]WAC] 2,732.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 60.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 520.00 SUBTOTAL 5 8,648.00 TOTAL FEES CALCULATED S 12,972.99 Escrow Amount - (Winter Only) TOTAL AMOUNT TO BE PAID TO CITY $ 12,972.99 Address: I r ( " I st 4 , Builder: 1i F 80 Two sets Building Plans V Two sets Surveys Survey sent to Engineering for review: A Energy Calcs yJ/ Digital Plans: oZ l7/ Plan Review letter generated t Review completed by Building Department Permit fees calculated 2OZ-6 t ec S Plan Review Checklist x Plan Review Letter: Survey approved by Engineering: V HVAC Loads Correct percentage of Brick & Stone Received by Building Department: Applicant contacted: 1 ' l G - 202-,% ., Date Address House size and finishing details L/ ECC verified HVAC Loss Calcs verified Footings and pads highlighted V Point loads V Any balloon framed walls and stud spacing? n Special stairway framing V Details on braced walls Blocking on floor framing Bearing wall blocking and bracing Verify any tempered glass Valuation report completed IContact applicant for revisions or questions: I What: I Who: I Date Contacted: Due Date for Revisions: Please provide the necessary information by this date: If not received by that date, the application will be removed from the review process and will be treated as a new permit when the information is provided. The review timeframe will start over at that time. V Valuation and size entered on front page of application Note finished or unfinished basement on front of application V Second page of application: Verify fixtures match plan: plumbing, mechanical, alarms Compete "Additional Information" section V Approved COS survey received from Engineering Plan Reviewer's Initials: MonticeNG llo RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite I MONTICELLO, MN 55362 Date: - 7/8/26 Contractor: City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4479 86th Street NE Monticello, MN 55362 JP Brooks 13700 Reimer Drive Maple Grove, MN 55311 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: Two Story, Slab on Grade 21454 Sq ft Finished 1 I _ Bldg Building, Mechanical & Plumbing Bob Ferguson — Chief Building Official 763) 271-3214 13ob.Fer ugson(a MonticelloMN.eov Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908 Wayne.Kalla(a MonticelloMN.g_oN Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(a N onticelloMN.Qov 763) 271-3222 Steve Kowalczyk — Inspector / Plan Reviewer 763) 271-3253 Steve.Kowalcak(c—uMonticelloMN. ox Electrical Amy Biren — Building Permit Technician Dennis Shafer — Electrical Inspector 763) 295-3060 763) 402-5732review outside of city 443 Lafayette Road North, St. Paul, MN 55155 Office Hrs: 7-8:30am http://www. dii.mn.gov/business/Qet-licenses-and- its/ nmits W an se i esig andscapmg Angela RE um — C evelopment Director Angela.Schuniaim a,.MonticelloMN.gov Bob Ferguson — Zoning Administrator 763) 271-3214 763)-271-3271Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer PW Utilities Matt.Leonard(&MonticelloMN.gov Ryan Melhouse — Project Engineer 763) 271-3227 Ryan.Melhouse(&MonticelloMN.gov Mario Frucci — Engineering Technician Mario.Frucci(a MonticelloMN.gov 763) 271-3213 Mat Stang - Water & Sewer Superintendent 763) 271-3274 Mat. Stang_AMonticelloMN.gov The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of 2 1 P a g e the Building Plans and Specifications. This review is for Buildinm Construction Permit review only. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION 1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note bldg n/a general Building Official review and authorization required prior to changes, modifications, 2 note or alterations. bldg n/a general NOTICE: This building must not be occupied until a Certificate of Occupancy has3note 1300.0220 been issued. bldg n/a general Final Building, Plumbing, and Heating inspections must be completed prior to4noteoccupancy. The owner or contractor must be present for final building inspection. 5 bldg n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note bldg n/a general Separate applications and permits Required for Sewer / Water Connection, Heating6noteA/C Systems, Plumbing, Fire Alarm Systems. bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection 1101.8 bldg MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F 8 299F .50 50 R315 bld, Buildings must be constructed per current building codes. 2020 MN State Building Code including: n/a general 2020 MN Residential Code 9 MR 1300 0 2023 National Electrical Code note 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R 31 - All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. I I bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are 12 note installed. bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans for13 note framing inspection. bldg n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical14 note work. 15 bldg Maintain 6" Earth to wood separation Eng Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fences are required. Maintain erosion controls until landscaping is completed. P a g c PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION h/<<L Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away 17 from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. 18 bldg R312 2 Window Fall Protection Required for all windows 6' above grade with sill height of less than 24", maximum opening must be less than 4". 19 bldg WARNING: Call Before You Dig! Gopher State One Call 651-454-0002 20 bldg. Blower Door Test Required: Prior to fmal Inspection — Air Leakage Rate Must Not Exceed 3 Air Exchanges Per Hour. 21 bldg Flash between House and Stoop. 22 1)1(1 R319 1 Install House Numbers: 4" minimum, visible from street. 23 bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / damper areas are exposed. 24 bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. 25 bldg R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic. Close horizontal to vertical penetrations. 26 bldg R301 1 Carry Concentrated loads to foundation — Concentrated loads must be solidly blocked and carried continuously to foundation. 27 1'h Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to daylight; schedule 40 pipe required). 28 bldg R402.4.1.1 Hardboard Backer Required behind tub / shower. 29 bldg Seal and Secure Sump Pump Basket Cover. 30 bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). 31 R405.2.3 Drain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install flexible hose connection extending to drainage area away from the foundation wall. 32 bldg R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for Subpart 6 future active radon ventilation system. bldg Radon gas vent pipes shall be provided with space around the vent pipe for future fan 33 R 1303.2402 installation. The space required for the future fan installation shall be a minimum of 24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. 34 bldg R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. 35 1'ld R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss manufacturer. h1* R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to 36 MN Res.Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code 37 TR703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: Detached Accessory Buildings) P a 9 C PLAN NO. DEPT SHEET/ SPEC. CODE SECTION COMMENTS SECTION h/dg 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2°d course of 38 R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, I anchor within V of each end. Exterior non -draining foundation insulation requirements: Shall have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal 39 bldg R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: 40 Zoning br Zoning OrdinanceZoningn The established maximum driveway of 20' for two -car garage lots overall, and 20' at the curb line/curb cut line for three -car garage lots as part of the Meadowbrook PUD bldg Floor joists and blocking shall be connected to the sill plate at the top of the wall 41 R404.1 1-4 with an approved connector with listed capacity meeting top of wall reaction in table R404.1(1). Spacing of blocking shall be in accordance with table R404.1(1). 42 bldg R314 3 If the office is to be used as a sleeping room. A smoke alarm is required in accordance to section R314.3 5 1 Page New COTiStrUCtiDn Energy Code Compliance Certificate PerR407.3 CertlfiCateA bulding cerfificateshaA be posted on orin the electrical dlsti bUtionpanel Date Cettifrca% hiaTmgAddress oftheDwelit orDwelling Unit4q $% R r ::: 90NameofResidentialContractor JP Brooks MN License Number BC686554 JmUlation Location Below a-rtire Slab Foundation Wall PWmeterofSlab on Grade Rim Joist (1st Floor) Rim Joist (2nd Flood-) 1Na11 CetTing, flat CetTmg, vaulted BayVndows or cantilevered areas Floors over unconditioned area Describe oiiierinsulafedareas BuUdiilg envelope airtightness_ Windows & Doors Average U-Factor (-M71"desskylights and one Type= Check AIIThatApply o m Com cm a o U m oma Q id 1Tt m 0 EU o w -6- o 2 o o Z u omo C m ao m m m m a Co NA R-15 v c/ R30 R30 R-Z r 4e R-4a t/ R30 NA AppIiances HeaSng Sysfem Dornestia ate Heate Fuel Type rNatat Gas NaNat Gas Manufacturer Bryant Richmond Model 915SBD4206DE17 Rating orSize fn atin pacityBTf> CO, 0000 insvon. 50 iljClenGy H P%, r 96.2 so esidenfial Load Calculafi Heating Loss Healing gain 3-, r7 b PIace your logo here IYasslve (ND Fan) Active (Wdh fan andmonomeler orothersysfem monRDring device) n (orf ffum location) of Fan: Attic er Please Dewnbe Here Pory Barrfer Fxtedorand Interiorasdkratedbycade interior of Foundation waft sYsfem airtightness= ` NA acing or GoofingDucfs Outside CondP&onedSpaces Not apprcabke 0 duets located in condiffoned space IN -value '33. Make-up Air Select- Type Coormg System Iec ryan BA013NR030BNG 7iriput i Tons= 2. EER FR 13 Cooling Load ZS Interlocked wrih exd Descnbe= Other: descnbe_ Location ofductorsystem: code L. Chas IIYIECHAWCALEI round duct OR Describe anyadditional or combined heating or cooling' Sourcesystems ifinsfalled- (e_g- two furnaces metal duct heat pump with gas back-up fumaoer or air Combustion An- Selecta Type Select Type Notregirired perm---_ code: Heat Remverveng,-&or(HRVJ Capacifyincfms= Low. Passive Ehe- wRecover ventilator High- CapacrTyln cf ris= Low so Ocher describe: Ifi fi_ l30 Bafancedveraa5on capacityinCfmsgLocationofdvctorsystem= Locationoffan(s), describe: Bat' roomsandLaundry Mechanical Room Capacity conffnuotts ventUation rate in ofms- Cfm s Totalventilff-DCmtermrrtent, co,tfUous)rateincfins= i3o s " mundductOR metal duct Bvtldets Associaton of Minnesota version jolOI4 Recher HVAC HVAC Load Calculations for 4479 86th Street NE Prepared By: Friday, June 26, 2026 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.. Auer Steel (Plymouth) Recher HVAC Plymouth. MN 55441 Page 2 Project Report -- -- - -- - - ---- - ---- General Project Information Project Title: Recher HVAC Project Date: Friday, June 26, 2026 Client Name: 4479 86th Street NE Desi n Data Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Dry Bulb Grains DifferenceDryBulb Winter: -15 Wet Bulb 15 mum n/a el.Hum n/a 72 n/a Summer: 88 71 44% 50% 72 30 Check Figures Total Building Supply CFM: 734 CFM Per Square ft.: 0.299 Square ft. of Room Area: 2,452 Square ft. Per Ton: 1,433 Volume (ft'): 20,689 FBuilding Loads Total Heating Required Including Ventilation Air: 37,176 Btuh 37.176 MBH Total Sensible Gain: 16,512 Btuh 80 % Total Latent Gain: 4,020 Btuh 20 % Total Cooling Required Including Ventilation Air: 20,532 Btuh 1.71 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 Page 3 Miscellaneous Report System 1 House Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 15 100% n/a 72 n/a Summer: 88 71 44% 50% 72 29.99 Fbuctsizin inputs Main Trunk Calculate: Yes Runouts Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Infiltration Specified: 0.150 AC/hr Summer 0.080 AC/hr 52 CFM 28 CFM Infiltration Actual: 0.150 AC/hr 0.080 AC/hr Above Grade Volume: X 20,689 Cu.ft. X 20,689 Cu.ft. 3,103 Cu.ft./hr 0.0167 1,655 Cu.ft./hr X 0.0167X Total Building Infiltration: 52 CFM 28 CFM Total Building Ventilation: 125 CFM 125 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 17.08 1.10 X 0.970 X 16.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.79 0.68 X 0.970 X 29.99 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.150 AC/hr (52 CFM), Construction: Tight Summer Infiltration Specified: 0.080 AC/hr (28 CFM), Construction: Tight C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth. MN 55441 Load Preview Report - Elite Software Development, Inc: Recher HVAC Sy. Sys SysNetft. Sen Lat Net Sen Duct Scope Ton Ton Area Gain Gain Gain Loss' CHtg CClg CAc Size Building 1.71 1,433 2,452 16,512 4,020 20,532 37,176 435 734 734 Svstem 1 1.71 1,433 2,452 16,512 4,020 20,532 37,176 435 734 734 10x1 Ventilation 854 2,474 3,327 4,643 Zone 1 2,452 15,659 1,546 17,205 32,533 435 734 734 10x1 1-Main Level 1,072 6,576 280 6,856 17,361 232 308 308 3-- 2-Upper Level 1,380 9,083 1,266 10,349 15,172 203 426 426 4-- CA ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 paw 5 Duct Size Preview Room or Source Minimu Maximu Rough Desig S Duct Duc Htg Clg Act. Duct Duct Name Velo Vela Facto U1 Loss Velocity Lengt Fl Bow Svstem 1 Supply Runouts Zone 1 1-Main Level Built -In 0 750 0.01 0.1 384.3 232 308 308 3-- 2-Upper Level Built -In 0 750 0.01 0.1 398.1 203 426 426 4-- Other Ducts in System 1 Supply Main Trunk Built -In 0 900 0.003 0.1 754.6 435 L 734 734 10x1 Svstem 1 Heatino Flow: 435 Cooling Flow: 734 CA ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. - Auer Steel (Plymouth) Recher HVAC' Plymouth MN 55441 Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Vector: Glazing -Vector Window, U-value 0.29, SHGC 203 5,119 0 6,254 6,254 0.31 11 P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 328 328 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 2419 13,678 0 2,563 2,563 cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-50: Roof/Ceiling-Under Attic with Insulation on Attic 1380.1 2,401 0 1,408 1,408 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 22D-10pm: Floor -Slab on grade, Vertical board insulation 152 4,536 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 20P-30: Floor -Over open crawl space or garage, Passive, 307.7 937 0 118 118 R-30 blanket insulation, any cover, U-value 0.035 Subtotals for structure: 27,731 0 10,671 10,671 People: 5 1,000 1,150 2,150 Equipment: 0 2,400 2,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 52, Summer CFM: 28 4,802 546 471 1,017 Ventilation: Winter CFM: 125, Summer CFM: 125 4,643 2,474 854 3,327 Exhaust: Winter CFM: 125, Summer CFM: 125 AED Excursion: 0 0 967 967 Total Building Load Totals: 37,176 4,020 16,512 20,532 Check Figures Total Building Supply CFM: 734 CFM Per Square ft.: 0.299 Square ft. of Room Area: 2,452 Square ft. Per Ton: 1,433 Volume (ft3): 20,689 Building Loads Total Heating Required Including Ventilation Air: 37,176 Btuh 37.176 MBH Total Sensible Gain: 16,512 Btuh 80 % Total Latent Gain: 4,020 Btuh 20 % Total Cooling Required Including Ventilation Air: 20,532 Btuh 1.71 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Building Pie Chart Floor 15% Roof 6% Wall 37% Wall 12% Glass 30% 11 Floor 1 % Roof 7% Elite Software Development, Inc. Recher HVAC Page 7 Ventilation 12% Infiltration 13% Door 3% Glass 14% AED Excursion 5% Ventilation 16% Infiltration 5% Equipment 12% People 10% Door 2% CA ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmmith MN .5..54d1 Elite Software Development, Inc. Recher HVAC 8 ; Detailed Room Loads -Room 1 -Main Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 33.5 ft. System Number: 1 Room Width: 32.0 ft. Zone Number: 1 Area: 1,072.0 sq.ft. Supply Air: 308 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.9 AC/hr Volume: 9,648 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 67 CFM Runout Air: 103 CFM Percent of Supply.: 22 Runout Duct Size: 7 in. Actual Summer Vent.: 52 CFM Runout Air Velocity: 384 ft./min. Percent of Supply: 17 Runout Air Velocity: 384 ft./min. Actual Winter Infil.: 27 CFM Actual Loss: 0.075 in.wg./100 ft. Actual Summer Infil.: 14 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantily Value HTM Loss HTM Gain Gain E -Wall-12F-Osw 40 X 9 312 0.065 5.7 1,764 1.1 0 331 S -Wall-12F-Osw 36 X 9 324 0.065 5.7 1,832 1.1 0 343 W -Wall-12F-Osw 40 X 9 274 0.065 5.7 1,549 1.1 0 290 N -Wall-12F-Osw 36 X 9 324 0.065 5.7 1,832 1.1 0 343 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.8 0 164 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.8 0 164 E -GIs-Vector shgc-0.31 0%S W -GIs-Vector shgc-0.31 0%S 6 9 0.290 0.290 25.2 151 25.2 227 33.7 33.7 0 0 202 303 W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 33.6 0 1,412 W -GIs-Vector shgc-0.31 O%S (2) 35 0.290 25.2 884 33.6 0 1,176 Floor-22D-1Opm 152 ft..Per. 152 0.343 29.8 4,536 0.0 0 0 Subtotals for Structure: 14,895 0 4,728 Infil.: Win.: 26.6, Sum.: 14.2 1,368 1.803 2,466 0.177 280 242 AED Excursion: 406 Equipment: 0 1,200 Room Totals: 17,361 280 6,576 C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) s Elite Software Development, Inc. Recher HVAC Detailed Room Loads -Room 2 -Upper Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 37.3 ft. System Number: 1 Room Width: 37.0 ft. Zone Number: 1 Area: 1,380.1 sq.ft. Supply Air: 426 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.3 AC/hr Volume: 11,041 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 58 CFM Runout Air: 106 CFM Percent of Supply.: 14 Runout Duct Size: 7 in. Actual Summer Vent.: 73 CFM Runout Air Velocity: 398 ft./min. Percent of Supply: 17 Runout Air Velocity: 398 ft./min. Actual Winter Infil.: 25 CFM Actual Loss: 0.081 in.wg./100 ft. Actual Summer Infil.: 13 CFM Item Area -U- Htg Sen E -Wall-12F-Osw 40 X 8 275 0.065 5.7 S -Wall-12F-Osw 41 X 8 313 0.065 5.7 W -Wall-12F-Osw 40 X 8 284 0.065 5.7 N -Wall-12F-Osw 41 X 8 313 0.065 5.7 E -GIs-Vector shgc-0.31 0%S (3) 45 0.290 25.2 S -GIs-Vector shgc-0.31 0%S 15 0.290 25.2 I W -GIs-Vector shgc-0.31 0%S 6 0.290 25.2 W -GIs-Vector shgc-0.31 0%S (2) 30 0.290 25.2 N -GIs-Vector shgc-0.31 100%S 15 0.290 25.2 UP-Ceil-166-50 37.3 X 37 1380.1 0.020 1.7 Floor-20P-30 17 X 18.1_ _ 307.7 0.035_ 3.0 Subtotals for Structure: Infil.: Win.: 25.2, Sum.: 13.4 AED Excursion: People: 200 lat/per, 230 sen/per: Equipment: 1,296 5 1.802 1,555 1,770 1,606 1,770 1,134 378 151 756 378 2,401 937 12,836 2,336 Room Totals: 15,172 Clg 1.1 1.1 1.1 1.1 33.6 18.7 33.7 33.6 10.5 1.0 0.4 0.177 Lat 0 0 0 0 0 0 0 0 0 0 0 0 266 1,000 0 1,266 Sen 291 332 301 332 1,512 281 202 1,008 158 1,408 118 5,943 229 561 1,150 1,200 9,083 C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc Auer Steel (Plymouth) Recher HVAC PI mouth MN 55441 ---_ Pa e 1 System 1 Room Load Summary - ----- _ Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM Zone 1--- 1 Main Level 1,072 17,361 232 3-7 384 6,576 280 308 308 2 Upper Level 1,380_ 15,172 203 - 4-7 398 9,083 1,266 426 426_ Ventilation 4,643 854 2,474 System 1 total 2,452 37,176 435 16,512 4,020 734 734 System 1 Main Trunk Size: 10x14 in. Velocity: 755 ft./min Loss per 100 ft.: 0.103 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.71 80% / 20% 16,512 4,020 20,532 Equipment Data Type: Heating System Natural Gas Furnace Cooling System Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE Sound: 0 0 SEER 0 0 Btuh 0 Btuh 0 Btuh C:\ ...\Recher HVAC - 4479 86th Street NE.rh9 Friday, June 26, 2026, 2:59 PM Job Truss Truss Type Oty Ply The Sylvia A -Upper Floor J261385-F2 H1GR Half Hip Girder 1 4 Job Reference (optional) P&M Truss, Isanti, MN 55040 0-11-0 0-11-0 N u? Cl N V 1 1 O V a0 M O N O O a0 a0 1 V Run: 25.30 S Oct 16 2025 Print: 25.3.0 S Oct 16 2025 MiTek Industries, Inc. Fri Jun 26 05:44:27 Page: 1 ID:wL3GIY WA3JgB4z3J LNuyl5zA?79-BKpVSRCUZitvBdZ4JCO6s62BIHprwT2N3eE WwEz2 Vfo 2-9-9 I 6-11-8 1 10-2-6 2-9-9 4-1-15 3-2-14 M18AHS 9x16 e M18AHS6x16 o 5 19 12-6-12 1 14-11-1 1 17-3-6 20-5-0 2-4-5 2-4-6 2-4-5 3-1-10 10x12a 5x10= 10x18= 4x5= 2x6 2x6rr 6x14= 5x8= M18AHS 10x16 = 4x8= 1 8 20-5-0 2-9-9 5-2-10 1 7-1-4 10-2-6 12-6-12 1 14-11-1 1 17-3-6 1 19-11-8 I 2-9-9 2-5-1 1 1-10-10 I 3-1-2 2-4-5 2-4-6 2 4-5 2-8-2 0-5-8 Scale = 1:40.9 Plate Offsets (X, Y): [3:0-2-0,0-1-8], [4:0-8-0,0-2-0], (9:0-6-12,0-1-8], [11:0-5-4,0-4-0], [12:Edge,0-2-8], [13:0-3-8,0-2-4], [15:0-7-8,0-6-0], [18:0-9-0,0-6-4], [19:0-3-8,0-2-8], [20:04-4,0-2-4] Loading psf) Spacing 1-4-0 CSI DEFL in loc) I/dell L/d PLATES GRIP TCLL (roof) 35.0 Plate Grip DOL 1.00 TC 0.86 Vert(LL) 0.25 16 963 360 M18AHS 142/136 TCDL 10.0 Lumber DOL 1.00 BC 0.87 Vert(CT) 0.39 16-17 610 240 MT20 2441190 BCLL 0.0' Rep Stress Incr NO WB 0.93 Horz(CT) 0.05 22 n/a n/a BCDL 10.0 Code IRC2018/TP12014 Matrix-MSH Wind(LL) 0.07 16 999 240 Weight: 674 lb FT = 20 LUMBER TOP CHORD 2x6 SP 2400F 2.0E 'Except' T2:2x6 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF Stud 'Except' W1,W5:2x10 SP 2400F 2.OE, W2,W9:2x4 SPF 1650F 1.5E, W10:2x6 SP 2400F 2.OE, W6,W4:2x4 SPF No.2 OTHERS 2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-6 max.): 6-11, 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 20=17820/0-5-8, (min. 0-3-11), 22=12101/0-5-0,(min. 0-4-12) Max Horiz 20=48 (LC 5) FORCES lb) - Max. Comp./Max. Ten. - All forces 250 Ib) or less except when shown. TOP CHORD 2-3=-22645/0, 3-4=-30701/0, 6-23=42489/0, 23-24=-42489/0, 7-24=42489/0, 7-8=-38435/0, 8-9=-38435/0, 9-10=-15543/0, 10-11=-15543/0, 2-20=-16208/0, 12-22=0/1 104, 11-22=0/1 104, 4-6=-31469/0 BOT CHORD 19-20=0/5324, 18-19=0/20277, 17-18=0/42298, 16-17=0/48014, 15-16=0/48014,14-15=0/27716, 13-14=0/27716,12-13=0/3747 WEBS 2-19=0/16081, 4-18=0/23726, 7-16=-712/0, 9-14=0/333, 8-15=-600/0, 10-13=435/0, 11-13=0/15661,9-13=-16410/0, 9-15=0/14451, 7-15=-12914/0, 6-17=0/2887, 6-18=-21603/0, 7-17=-6815/0, 3-19=-7759/0, 3-18=0/10771, 11-22=-12798/0 NOTES 1) Special loads equally between all plies. 2) 4-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x10 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 4 rows staggered at 0-4-0 oc. Web connected as follows: 2x4 - 1 row at 0-6-0 oc, 2x10 5 rows staggered at 04-0 oc. Attach TC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. Attach BC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-16; Vul1=115mph (3-second gust) Vasd=91 mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. 11; Exp B; Enclosed; MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) The Fabrication Tolerance at joint 15 = 12 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 11) Bearing at joint(s) 22 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Load case(s) 1, 2 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 12310 lb down at 7-2-10 on bottom chord. The design/ selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (lb/ft) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 6-23=-220, 11-23=-316, 12-20=-13, 4-6=-60 Concentrated Loads (lb) Vert: 18=-12310, 7=-1 1600, 24=-1240 2) Dead + 0.75 Roof Live (balanced) + 0.75 Attic Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (lb/ft) Vert: 1-2=48, 24=48, 4-5=48, 6-23=-214, 11-23=-295, 12-20=-13, 4-6=48 Concentrated Loads (lb) Vert: 18=-10352, 7=-9755, 24=-1043 40-00.00 PLY ORDER CONNECTI USE NAILING SCHEDULE ON TRUSS DRAWI IN LIEU OF BOLTS SPECIFIED FOR THE TOF USE (50) SDW22638 SCREWS. (RIND ROWS SEE DETAIL IN FLOOR PACKET rn rn rn rn b U U z d d rn m z m m 4 b z rn r z N z OJ r cn m z A 0) 0 D D l' I O 1x y c0 z O D 1 c: a D m Z T T m N lJ C D O z Z m r' O OO0 cn 0 c D D T -:g u v rn T m m Z Z rn m m 0 m T O O A D O m v Cn o W o l V W W u;;a m m m cn N rn M SIGN RESIDENCE F( QMI HOME 4479 86TH STREI LOT 12 — BLOC EDMONSON RI MONTICELLO., MIN R: COPYRIGHT NOTICE THIS ARCHITECTURAL PLAN SET AND THE DESIGN ELEMENTS REPRESENTED ON EACH INDIVIDUAL PAGE INCLUDING BUT NOT LIMITED TO; FLOOR PLAN AND ELEVATION DESIGN, DETAILS, INFORMATION, AND CONCEPTS IS PROPRIETARY AND DEVELOPED FOR THE EXCLUSIVE USE OF JP BROOKS INC. rn NE USE AND/OR REPRODUCTION OF ANY PORTION OF THIS PLAN SET IN ANY FORM IS STRICTLY PROHIBITED WITHOUT EXPRESSED WRITTEN PERMISSION OF JPTyBROOKS. VIOLATION WILL BE SUBJECT TO ALL APPLICABLE COPYRIGHT LAWS. 04 r C BUILDING CODE AND DESIGN DISCLAIMER GE THE HOME PLAN REPRESENTED IN THIS PLAN SET HAS BEEN DESIGN TO COMPLY WITH WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AND THE 2020 D ENERGY CONSERVATION CODE (IECC). THE DESIGN OF THIS HOME PLAN IS DRAWN AS ACCURATELY AS POSSIBLE, HOWEVER, FINAL NESOTA CONSTRUCTION MAY DIFFER SLIGHTLY FROM PLANS DUE TO STRUCTURAL ADJUSTMENTS, FIELD CONDITIONS, OR OTHER DESIGN CONSIDERATIONS. J C m O rn m N O. M M r- w W fn O Z Cn m v Z- o Z m i1 O o v • M oo O off. O DoAcn N U' - A O 1 4479 86th Street NE CITY OF Lot 12 Block 4 - Edmonson Ridge Monticello BUILDING SAFETY Builder: J.P. Brooks Builders 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. Proposed building elevations of lot corners. Proposed elevations at building corners. Proposed elevations on the side yard swales at the extension of building corners and high points. Proposed and as -built elevations of garage slab and lowest floor on walkouts. Top of curb elevation at the extension of property lines and center of driveway. Proposed elevations and location of any critical drainage ways located on the site natural or man-made indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Erosion control *Must be installed prior to starting construction and maintained to be compliant with City requirements and project SWPPP. Follow City Standard Detail Plate 6006. Proposed driveway location, width at lot line, % of slope. Show proposed porches, cantilevers, bay windows, and decks (if being constructed). N/A Show individual significant trees 36" DBH (Diameter Breast Height)or larger N/A Existing or proposed retaining wall(s) top and bottom elevations. Show adjacent property topo related to drainage with arrows. Proposed sump pump outlet location on buildin footprint (natural drainage or piped to curb). Show any Drain Tile installed in the yard. show sump pump location on final as -built City will accept only originals or quality hard copies of the as -built survey and certification of grading. NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTON LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. SANITARY STUB INVERT=957.3± PER PLAN. PROPOSED HOUSE ELEVATIONS Top of Foundation Elev = 968.4 Garage Floor Elev = 968.1 ELEV PER GRADING PLAN Plans by Alliant. Garage Floor Elev = 968.1 Lowest Floor Elevation = 961.1 Rear Elevation = 965.1 L - Lookout SOD AREA: Full Yard = 7,779± S.F. 30' Behind House = 2,985± S.F. REFERENCE BENCHMARK: Rim of sanitary manhole on 86th St. NE near West plat boundary. Elevation = 957.15 feet (Plat Datum) PROPOSED IMPERVIOUS SURFACES Total lot Area = 10,376± S.F. House/Stoop Area = 1,840± S.F. Driveway/Walk Area = 749 S.F. Total Impervious Area = 2,589± S.F. (25.0%) Certificate of Survey For JP Brooks Builders Lot 12, Block 4, EDMONSON RIDGE City of Monticello, Wright County, Minnesota Address: 4479 86th Street NE, Monticello, MN 55362 DRIVEWAY AREA TO STREET: 846± S.F. (Excluding Sidewalk) PROPOSED DING SURVEY ZONING SETBACKS P.U.D. OFFSETS OS#1 = 967.46 (B ApprOV6d Date 7/16/202625' Front *Additional Compaction HOUSE TYPE OS#2 = 966.53 7' Side 30' Rear testing will be required Slab On Grade OS#3 = 965.74 OS#4 = 966.50 20' Side Street The Sylvia) IPY" SCS 44110 ' I S`° I I o L ws ; RIM=956.43 ; I ;`,;;I I I;`,; ; i I;`.; I X I 0tO 1 ham. s x9s i , 'o ,`' I , I 96s X A I X0 ^ \\ a \ 11 + 958.8 I X962O i I X h0 ° I oo I k j " ` a i 960.6 X, o,` °` O X I PID: 155 264 004110 xlXXI1 X X , 9565 x 96' I \\ i j I I I I House#4489 t e ` 12 f 95 (Under I ° OD: 155-264-004030 ` I b T- I i tII0I 1 Construction) o /-,,,- x os#3 I u----- E957.2 phi 965.74phi' ro \ OS#4 A t "' S x a/ 8 23'10"E 192.73 % 6S - ` I ` 7 o ' ° 00 9 0966.50 ct rn FIPY2" in Post >7 2z' ^ 119.3 I ( c;? ,, _ _ 6 , 6 48r' r--------- .:----...... ------------' s i -- _00 9Gs 2%_ '%% 2% 25.37 'r rOy s D12 / I............r......................r..- ..- ::--.- .-6.1. --------967.9 --- 9- K ir<i 4411 I ..%1y. o) 3C) i I X ° <oroi% 5/° 96S9 i 36.00- o ' 1 .13/° PHouseoI^ 25112O[SZS I / 1 I 5#4479® ISj+ g651 0 I Iro AiCS-- ws wsl X I ro oX e o,O° I I I.00 I < ( 39.4 0 I 960.2- rn ' s raq c' rvl I II Proposed I d°- ro ' >' X I +965.2 r o p g 00Xi i 6LJ v LJD:155264-004 2 0,o Driveway 10tK 966 Lo PID:155 264-004020 rn , / X 5 m q0 co6.4% Pi %o' v S83I - / b 1 ` k ( Area: 10,376± S.F.°ol dd LL+ aoi 0 I(0.24 AC.)I+J N `P6`s -+XI ,%t o 3. 96'965ol 1.00 4-rn5% IIOO 12I / - 1 1 -- 7-11(;r ------------------------/ ++ \ 4`X - IPY,------ - --- - ---- I46. 00 16.3 2 44110\ 118.21 \ 0 966oI 3%3%_ , -o 96 8 9 '- 0 ° / --- 48. 00 - I - - 25.37 S88° 2310"E 191.58 i0%% / ' IPY" CP OS #2 0to oco _ o ra1Q%;- l 44110 966.53 X I I 1 0 PID: 155 264-004010 X X / X0 I 964.8 Xo Drainage and Utility Easements are shown thus: PID:155 264-004134 xisting House 4465 1 12 12 I N.T.S. I Being 6 feet in width and adjoining lot lines and 12 feet in width and adjoining street lines and rear lot lines as shown on this plat, unless otherwise shown. B 1 6j T 96746_ 11 0° 14411 0 1 I - t tt 9671 i a I ws ° wS I 1 j SIQ I I ` DRAWN BY' DATE WIDSETH JR CHECKED BY. ARCHFTECTS • ENGINEERS • SCIENTISTS SURVEYORS CAW 0 20' 40' SCALE IN FEET oo] TV LEGEND PROPOSED ELEVATION PROPOSED DRAINAGE ARROWS STAKED LATH STAKED HUB TV PEDESTAL T TELECOM PEDESTAL E ELECTRIC PEDESTAL S® El WCS A A - d - SANITARY SERVICE STORM SEWER CATCH BASIN CURB STOP BITUMINOUS SURFACE CONCRETE SURFACE 1234----- CONTOURS (PER PLAN) EASEMENT LINE ADJOINING LOT LINE BOUNDARY LINE SETBACK LINE STORM SEWER GRAVITY MAIN PER PLAN) WATER MAIN LINE (PER PLAN) Ws WATER SERVICE LINE (PER PLAN) SANITARY GRAVITY MAIN PER PLAN) ss SANITARY SERVICE LINE (PER PLAN) 0 O CHAINLINK FENCE AMENDMENT DESC PREPARED FOR: JP Brooks Builders I PROJECT #: 2026-11 I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AMA DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA, ._-