Loading...
2025-00282CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 4480 86TH ST NE PIN 155264003030 LEGAL DESC EDMONSON RIDGE LOT 003 BLOCK 003 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION : $ 264,745.02 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: 698 SQ FT FINISHED BASEMENT 800 SQ FT UNFINISHED BASEMENT --CRAWL SPACE 800 SQ FT FINISHED MAIN FLOOR 784 SQ FT SECOND FLOOR 36 SQ FT OPEN PORCH 640 SQ FT GARAGE FIREPLACE: NO A/C: YES MECHANICAL: 10 PLUMBING: 20 WATER METER 1 (MAIN) 1.00 WAC UNITS 1.00 APPLICANT JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55311- 763) 999-7153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant _Z-11 Date 3 41 W ! d2 O a,5- d9; Bldg Official Date SAC UNITS 2 0 2 5— 0 0 2 8 2* DATE ISSUED: 03/14/202- Permit 4: 2025-00282 BUILDING PERMIT FEE PLAN REVIEW STATE SURCHARGE, BLDG VAL SAC FEE 30% SAC FEE 70% WATER ACCESS CHARGE, RESI COMB CONNECTION FEE / RESI SEWER / WATER EXCAVATION PERMIT CONTRACTOR LICENSE VERIFICATION FEE ASSESSMENT SEARCH FEE UTILITY LOCATE FEE, RESI WATER METER I (MAIN) MN STATE SALES TAX (MTR 1) TOTAL Payment(s) CHECK 22628 2,033.48 1,321.76 132.37 1,449.90 3,383.10 2,153.00 130.00 130.00 5.00 60.00 50.00 475.00 35.03 11,358.64 1 1.358.64 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY OF Monticeflo BUILDING SAFETY PERMIT # 505 WALNUT STREET, SUITE 1 MONTICELLO, MN 55362 City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: & I q D 2 &D 5tv-,* 1-i & . ZONED LEGAL: Lot Block ?j Plat L-J' M 0 1 l c) 1 Ri 8 (y..r Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders State License #: 656554 Address: 13700 Reimer Drive Eng./Architect Name: Address: Plumber Name: Northwoods Plumbing Address: 30799 73rd Street Mechanical Name: Recher HVAC Address: 1125 Mississippi Drive North Twe of Work L( New Addition Alteration Repair Move Other Phone: 763-285-4790 E-Mail: shelly@jpbrooks.com City: Maple Grove State: MN Zip: 55311 City: City: Pierz City: Champlin T pe of Construction Single Family Duplex Multi -Family Commercial Industrial Other Phone: State: Zip: Phone: 763-717-8757 State: MN Zip: 56364 Phone: 612-802-6525 State: MN Zip: 55316 Building Informati"on,. Use of building (JQAAs (I of stories Floor area sq. ft. 01 c) S Estimated value 2Uy1)'-V5 of construction $ 7 D scription of work: 1 V I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public pro er including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. G SEE BAf1R PT,T 1 R{G c l r) Vi C AND MECHANICAL INFO. Applicant Signa e T Application Date APPLICANT: Please show_ fixtures that are applicable. Fi e Suppression : (if applicable) Plumbinz: (if applicable) Mechanical. (if applicable) No. ixture Tvpe No. Fixture Tvve No. Fixture Tvve kler Heads Water Closet (toilet) I Furnace Oth Special FS Device fLq Z Bathtub 1 1 Gas Meter 5' Lavatory (wash basin) Range Hood a Z Shower Gas Range I 1 Kitchen Sink C Water Heater Dishwasher Air Conditioning Laundry Tub Mech. Fireplace 1 Clothes Washer L4 Bathroom(s) Exhaust Fan Fire Alarm: (if applicable) I 1 Water Heater 1 Air Exchanger Urinal Dryer No. Fixture Tvve Drinking Fountain Gas Opening w/o Fixture Floor Drain J # of Devices Slop Sink Other IL Outside Faucet Z TOTAL Future Owner Information: Name: Address: D TOTAL FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No City: ADDITIONAL INFORMATION: Valuation: "l --) 4 b State: Zip: Construction Type: V b Occupancy Group: 'Qe-, Phone #: Division: Square Footage: ZztZ. of Stories: — of Residential Units: Maximum Occupancy: Fire Sprinklers: Yes .A No Off -Street Parking Covered: 3 Off -Street Parking Uncovered: 4j., t 0 Z ZBuildingOfficial / I RDZ 5- BPT: / / Monticello 2025 Residential Building Permit Calculator Address: 4480 86th St NE Legal: Lot 3 Block 3 Edmonson Ridge 1 = Yes 0 = No New Residence: I House Type: Multi Level 1 = Yes 0 = No 1 = Yes 0 = No Permit Applicant: Contractor: 1 Plan Review: I JP Brooks Owner: 0 Master Plan: 0 Master Plan Review = 25% of Building Permit Fee) I Ise June 016 Valuation Factor TOTAL Crawl Space 800 S 15.27 12,216.00 Unfinished Basement Area 0 $ 16.50 Finished Basement Area 698 $ 44.05 30,746.90 Main/First Floor Area 800 $ 125.00 100,000.00 Second Floor Area 784 $ 115.00 90,160.00 Detached Garage 0 $ 60.00 Attached Garage 640 $ 47.33 30,291.20 Garage Conversion to Living Space 0 $ 47.44 CarpordGazebo 0 $ 30.90 Pole Barn 0 $ 19.03 Shed - greater than 200 SF 0 $ 40.00 Lean -to -Shed 0 $ 13.25 Basement Finish Only 0 $ 16.00 Remodeled Area 0 $ 17.39 Porch (open) 36 $ 36.97 1,330.92 Porch (3-Season) 0 $ 60.00 Porch (3-Season on Existing Deck) 0 $ 55.00 Porch (Screen Porch/Breezeway) 0 $ 58.48 Solarium 0 $ 94.90 Deck 0 $ 20.00 Deck (Screen In & Roof Over Existing) 0 $ 29.80 In -Ground Pool 0 $ 23.18 Above -Ground Pool 0 $ 11.31 Fireplace - Mechanical/Gas 0 $ 4,892.50 Fireplace - Masonry 0 $ 22,660.00 Elevator/Lift/Other 0 CALCULATED BUILDING VALUATION S 264,745.02 1 = Yes 0 = No Water Hook-up I Sanitary Sewer Hook-up I FEES: BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% $ 2,032.82 PLAN CHECK 1,321.33 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 132.37 SUBTOTAL 3,491.52 SEWER FEE [SAC] 4,833.00 WATER FEE ]WAC] 2,153.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 60.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 510.03 SUBTOTAL 7,866.03 TOTAL FEES CALCULATED 11.357.55 Escrow Amount - (Winter Only) TOTAL AMOUNT TO BE PAID TO CITY 119357.55 CITY OF i/Ionticello BUILDING SAFETY RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite 1 MONTICELLO, MN 55362 Date: 2/6/2025 Contractor: City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4480 86th Street NE JP Brooks 13700 Reimer Drive Maple Grove, MN 55311 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: Three level split with electric fireplace and luxury suite Finished lower level 29282 Sq ft Finished 1 1 Page Bldg Building, Mechanical &Plumbing Bob Ferguson — Chief Building Official 763) 271-3214 Bob.Fer ,uson a MonticelloMN.g Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908 Wayne.Kalla(a MonticelloMN.Pov Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(aa;MonticelloMN. ov 763) 271-3222 Amy Biren — Building Permit Technician 763) 295-3060 buildingdepartmentA,MonticelloMN.gov review Electrical Bill Husom — Electrical Inspector (612)490-0488 outside Office Hrs: 7-8:30am of city Pen -nits I Minnesota Department of Labor and Industry mn.v-ov ) 910 —181h St SE, Buffalo, MN 55313 CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-3224 Angela.Schumami(u gov Bob Ferguson — Zoning Administrator 763) 271-3214 ob.F r uson a Monti ell N. ov Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer (763)-271-3271 PW Utilities Matt. Leonard(c-t'MonticelloMN.cOV Ryan Melhouse — Project Engineer (763) 271-3227 Rvan.Melhouse((i.)MonticelloMN.cov Mario Frucci — Engineering Technician Mario. Frucci(rtMonticelloMN.cov (763) 271-3213 Mat Stang - Water & Sewer Superintendent (763) 271-3274 Mat.Stane(a,MonticelloMN.cov The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. Page The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of the Building Plans and Specifications. This review is for Buildine Construction Permit review onlv. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION 1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note 2 bldg n/a general Building Official review and authorization required prior to changes, modifications, note or alterations. 3 bldg n/a general 1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has note been issued. 4 bldg n/a general Final Building, Plumbing, and Heating inspections must be completed prior to note occupancy. Owner or contractor must be present for final building inspection. 5 bldg n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note 6 bldg n/a general Separate applications and permits Required for Sewer / Water Connection, Heating note A/C Systems, Plumbing, Fire Alarm Systems. bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection N1101.8) Bldg MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F 8 299F .50 50 R315 bldg Buildings must be constructed per current building codes. 2020 MN State Building Code including: n/a general 0 2020 MN Residential Code 9 note MR 1300 2023 National Electrical Code 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. 11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans 12 bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are note installed. 13 bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans note for framing inspection. 14 bldg n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical note work. 15 bldg Maintain 6" Earth to wood separation 3 1 Page PLAN NO. DEPT SHEET/ SPEC. CODE SECTION COMMENTS SECTION Eng Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fence are required. Maintain erosion controls until landscaping is completed. bldg Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away 17 from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. 18 bldg R312 2 Window Fall Protection Required for all windows 6' above grade with sill height of less than 24", maximum opening must be less than 4". 19 bldg WARNING: Call Before You Dig! Gopher State one 651-454-0002 20 bldg. Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not Exceed 3 Air Exchanges Per Hour. 21 bldg Flash between House and Stoop. 22 bldg R319.1 Install House Numbers: 4" minimum, visible from street. 23 bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / damper areas are exposed. 24 bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. 25 bldg R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic. Close horizontal to vertical penetrations. 26 bldg R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly blocked and carried continuously to foundation. 27 bldg Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to daylight; schedule 40 pipe required). 28 bldg R402.4.1.1 Hardboard Backer Required behind tub / shower. 29 bldg Seal and Secure Sump Pump Basket Cover. 30 bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). 31 bldg R405.2.3 Fain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install flexible hose connection extending to drainage area away from the foundation wall. 32 bldg R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for Subpart 6 future active radon ventilation system. bldg Radon gas vent pipes shall be provided with space around the vent pipe for future fan 33 R 1303.2402 installation. The space required for the future fan installation shall be a minimum of 24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. 34 hh k R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. 35 bldg R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss manufacture. 4 1 Page PLAN NO. DEPT SHEET/ CODE SPEC. SECTION COMMENTS SECTION bldg R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to 36 MN Res.Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code 37 bldg R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: Detached Accessory Buildings) Bldg 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2nd course of 38 R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, 1 anchor within 1' of each end. Exterior non -draining foundation insulation requirements: have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal 39 bldg R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: 40 zoning R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to a width Not to Exceed 28 Ft. and the Public Street. 5 1 Page New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Post panel. Mailing Address oft pw 1fiR or Dwelling Unit LALA S 0 K(0 'S Name of Residential ConbmctorJP Brooks THERMAL ENVELOPE Insulation location Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope airtightness: 0 0 a) n F m TO R-15 R-15 R-30 R-30 R-21 R-48 R-46 R-30 NA Windows & Doors Average U-Factor (excludes skylights and one door) U: Solar Heat Gain Coefficient (SHGC): MECHANICAL SYSTEMS CNTJV\k, MN License Number BC 686554 Place your logo here RADON CONTROL SYSTEM Type: Check All That Apply 0 Passive (No Fan) With fian and monometer r_ ElActiveorother system monitoring device) Location (or future location) of Fan: m V c R 0. m Attic 3 V, U °' Q. 0 Lit C1 n m C zCUro to to 0 o to 4. o a' E E m o a z N U_ W U_ to C0 ti C m 5 Other Please Describe Here Poly Banter Exterior and lntedor as dictated by code Interior of Foundation Wet! Duct system airtightness: I NA Heating or Cooling Ducts Outside Conditioned Spaces Not applicable, all ducts located in conditioned space R value Appliances Heating System Domestic Water Heater Nat. Gas Nat. GasFuelType Bryant RichmondManufacturer iRD'S A 1_A70M 1Model Input in BTUs Capacity InIn Gallons:150RatingorSizett)40k AFUE or Efficiency HSPF%, 96.2 90 Heating Loss Heating Gain Residential Load Calculatit ' 3 t O1 I MECHANICAL VENTILATION SYSTEM Make-up Air Select a Type Cooling System Not required per meth. code Elect. Passive Bryant Powered u Interlocked with exhaust device. BA013NR030BNG Describe: Output r Other, describe: in Tons: SEER Location of duct orsystem: EER 113 Cooling Load I c Cfm's round duct OR metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type i Heat Recover Ventilator (HRV) Capacity in cfms: Low: lHigh: High: Energy Recover Ventilator (ERV) Capacity in cfmsLow: so 1130 Balanced Ventilation capacity in cfms: Location offan(s), describe: I Bathrooms and Laundry Capacity, continuous ventilation rate In cfms: so-1s0 Total ventilation Cintermittent + continuous) rate in alms: 270 Combustion Air Select Type 1 Not required per meth. code Passive Other, describe: Location of duct or system: Mechanical Room Cfm' s s " round duct OR metal duct Builders Associaton of Minnesota version 101014 Recher HVAC HVAC Load Calculations for 4480 86th Street Prepared By: Friday, March 7, 2025 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) PlymoOh—_MN 55441 Project Report General Project Information Project Title. Recher HVAC Project Date: Friday, January 31, 2025 Client Name: 4480 86th Street Design Data Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation- 834 ft. Altitude Factor: 0.970 Elite Software Development, Inc. Recher HVAC Page 2 Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Indoor Indoor Grains Winter: -15 15 RLJHm n/a Rel.Hum n/a Dry Bulb 72 Difference n/a Summer: 88 71 44% 50% 75 24 Check Figures Total Building Supply CFM: 934 Square ft. of Room Area: 2,282 Volume (ft3): 17,324 Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: CFM Per Square ft.: 0.409 Square ft. Per Ton: 1,101 74,340 Btuh 74.340 MBH 21,667 Btuh 87 % 3,208 Btuh 13 % 24,875 Btuh 2.07 Tons (Based On Sensible + Latent) Notes__ Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Miscellaneous Report System 1 House Outdoor Outdoor Outdoor Input Data Dry Bulb Wet Bulb Rel.Hum Winter: 15 15 100% Summer: 88 71 44% Duct § inglnputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Infiltration Specified: Winter 0.110 AC/hr Summer 0.060 AC/hr 32 CFM 17 CFM Infiltration Actual: 0.110 AC/hr 0.060 AC/hr Above Grade Volume: X 17,324 Cu.ft. X 17,324 Cu.ft. 1,906 Cu.ft./hr 1,039 Cu.ft./hr Total Building Infiltration: X 0.0167 32 CFM X 0.0167 17 CFM Total Building Ventilation: 125 CFM 125 CFM Elite Software Development, Inc. Recher HVAC Page 3 Indoor Indoor Grains Rel.Hum Dry Bulb Difference n/a 72 n/a 50% 75 23.51 System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.110 AC/hr (32 CFM), Construction: Tight Summer Infiltration Specified: 0.060 AC/hr (17 CFM), Construction: Tight auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth MN_55441 Load Preview Report Scope Buildinq Svstem 1 Ventilation Zone 1 1-Lower Level 2-Main Level 3-Upper Level Elite Software Development, Inc. 6 Recher HVAC Pie 4 Nei. ft.; Se n La Net Se Sys Htg Sy Clg Sys Ac Duc Ton /Tor Are Gai Gai Gair Loss CFM, CFM CFM Size 2.07 1,101 2,282 21,667 3,208 24,875 74,340 840 934 934 2.07 1,101 2,282 21,667 3,208 24,875 74,340 840 934 934 10x1 1,734 1,939 3,673 11,606 2,282 19,933 1,269 21,202 62,734 840 934 934 10x1 i 698 4,831 269 5,100 31,532 422 226 226 3--6 800 8,785 103 8,888 23,111 309 412 412 4-7 784 6,318 897 7,215 8,091 108 296 296 3--7 auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Duct Size Pre vie w Room or Minimurr Duct Name SourceI Velocit` Svstem 1 Supply Runouts Zone 1 1-Lower Level Built -In 0 2-Main Level Built -In 0 3-Upper Level Built -In 0 Other Ducts in System 1 Supply Main Trunk Built -In 0 Svstem 1 Heating Flow: 840 Cooling Flow: 934 Elite Software Development, Inc. Recher HVAC Page 5 750 0.01 0.1 384.2 750 0.01 0.1 385 750 0.01 0.1 369.2 900 0.003 0.1 791 Summary clg I Act. I Duct 422 _ 226 3--6 309= 412 4--7 108 _ 296 3--7 840934 10x1fj auerfiles\ FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth MN 55441 Page_6_. Total Building Summary Loads Component Area Sen Lat Sen Total description_ Quan Loss Gain Gain Gain Vector: Glazing -Vector Winows , U-value 0.29, SHGC 256 6,459 0 7,275 7,275 0.31 11 P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292 15BO-10sf-8: Wall -Basement, , R-10 board insulation to 624 2,714 0 0 0 floor, no interior finish, 8' floor depth, U-value 0.05 12F-Osw.- Wall -Frame, R-21 insulation in 2 x 6 stud 1740 9,839 0 1,504 1,504 cavity, no board insulation, siding finish, wood studs, U-value 0.065 15BO-10sf-4- Wall -Basement, , R-10 board insulation to 136 639 0 0 0 floor, no interior finish, 4' floor depth, U-value 0.054 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 1584 2,756 0 1,521 1,521 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 22A-ph: Floor -Slab on grade, No edge insulation, no 194 22,920 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil, U-value 1.358 20P-0c: Floor -Over open crawl space or garage, Passive, 400 13,398 0 1,232 1,232 no insulation, carpet or hardwood, U-value 0.385 Subtotals for structure: 59,785 0 11,824 11,824 People: 5 1,000 1,150 2,150 Equipment: 0 3,600 3,600 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 32, Summer CFM: 17 2,949 269 240 509 Ventilation: Winter CFM: 125, Summer CFM: 125 11,606 1,939 1,734 3,673 Exhaust: Winter CFM: 125, Summer CFM: 125 AED Excursion: 0 0 3,119 3,119 Total Building Load Totals: 74,340 3,208 21,667 24,875 Check Figures Total Building Supply CFM: 934 CFM Per Square ft.: 0.409 Square ft. of Room Area: 2,282 Square ft. Per Ton: 1,101 Volume (ft'): 17,324 Building _Loads Total Heating Required Including Ventilation Air: 74,340 Btuh 74.340 MBH Total Sensible Gain: 21,667 Btuh 87 % Total Latent Gain: 3,208 Btuh 13 % Total Cooling Required Including Ventilation Air: 24,875 Btuh 2.07 Tons (Based On Sensible + Latent) motes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Building Pie Chart Floor 49% Elite Software Development, Inc. Recher HVAC Paae 7 Ventilation 16% Infiltration 4% Door 1 % Glass 9% VVall 18% Roof 4% Floor 5% Roof 6% AED Excursion 13% Wall 6% Glass 29% Door 1 % People 9% Ventilation 15% Infiltration 2% Equipment 14% auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 - Paae 8 Detailed Room Loads T Room 1 - Lower Level (Average Load Procedure I General — Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 26.8 ft. System Number: 1 Room Width: 26.0 ft. Zone Number: 1 Area: 697.8 sq.ft. Supply Air: 226 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 5,583 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 63 CFM Runout Air: 75 CFM Percent of Supply.: 28 % Runout Duct Size: 6 in. Actual Summer Vent.: 30 CFM Runout Air Velocity: 384 ft./min. Percent of Supply: 13 % Runout Air Velocity: 384 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.093 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantity Value HTM - - - Loss HTM_ Gain Gain E -Wall-15BO-10sf-8 48 X 8 384 0.050 4.4 1,670 0.0 0 0 S -Wall-15BO-10sf-8 30 X 8 240 0.050 4.4 1,044 0.0 0 0 W -Wall-12F-Osw 48 X 8 322 0.065 5.7 1,821 0.9 0 278 N -Wall-15BO-10sf-4 34 X 4 136 0.054 4.7 639 0.0 0 0 N -Wall-12F-Osw 34 X 4 118 0.065 5.7 667 0.9 0 102 W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 32.7 0 1,375 W -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 32.8 0 655 N -GIs-Vector shgc-0.31 100%S 18 0.290 25.2 454 9.7 0 174 Floor-22A-ph 194 ft..Per. 194 1.358 118.1 22,920 0.0 0 0 Subtotals for Structure: 30,780 0 2,584 InfiI.: Win.: 8. 1, Sum.: 4.4 520 1.446 752 0.117 69 61 AED Excursion: 756 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 0 1,200 Room Totals: 31,532 269 4,831 i i I I auerfiles\FILES ...\Recher HVAC 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 Detailed Room Loads -Room 2 -Main Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 28.6 ft. System Number: 1 Room Width: 28.0 ft. Zone Number: 1 Area: 800.0 sq.ft. Supply Air: 412 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.1 AC/hr Volume: 8,000 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 46 CFM Runout Air: 103 CFM Percent of Supply.: 11 % Runout Duct Size: 7 in. Actual Summer Vent.: 55 CFM Runout Air Velocity: 385 ft./min. Percent of Supply: 13 % Runout Air Velocity: 385 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.075 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item Area U- Htg Sen Clg Lat Se Description Quantity Value HTM Loss HTM Gain G_ aiI , E -Wall-12F-Osw 24 X 10 186 0.065 5.7 1,052 0.9 0 161 S -Wall-12F-Osw 30 X 10 300 0.065 5.7 1,696 0.9 0 259 W -Wall-12F-Osw 24 X 10 152 0.065 5.7 860 0.9 0 131 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -GIs-Vector shgc-0.31 0%S 12 0.290 25.2 303 32.8 0 393 W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 32.7 0 1,375 W -GIs-Vector shgc-0.31 0%S (2) 26 0.290 25.2 656 32.8 0 852 W -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 32.8 0 655 UP-Ceil-1613-50 28.6 X 28 800 0.020 1.7 1,392 1.0 0 768 Floor-20P-Oc 20 X 20 400 0.385 33.5 13,398 3.1 0 1,232 Subtotals for Structure: 21,982 0 6,118 Infil.: Win.: 12.2, Sum.: 6.6 780 1.447 1,129 0.118 103 92 AED Excursion: 1,375 Equipment: 0 1,200 Room Totals: 23,111 103 8,785 auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steei (Plymouth) Recher HVAC Plymouth, MN 5_5441 _ Page 10 Detailed Room Loads - Room 3 - Upper Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 28.0 ft. System Number: 1 Room Width: 28.0 ft. Zone Number: 1 Area: 784.0 sq.ft. Supply Air: 296 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.5 AC/hr Volume: 7,056 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 16 CFM Runout Air: 99 CFM Percent of Supply.: 5 Runout Duct Size: 7 in. Actual Summer Vent.: 40 CFM Runout Air Velocity: 369 ft./min. Percent of Supply: 13 Runout Air Velocity: 369 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.069 in.wg./100 ft. Actual Summer Infil.: 6 CFM Item Area U- Htg Sen Clg Lat Se Description Quantity Value HTM - Loss HTM Gain Gai E -Wall-12F-Osw 24 X 9 216 0.065 5.7 1,221 0.9 0 187 W -Wall-12F-Osw 24 X 9 170 0.065 5.7 961 0.9 0 147 N -Wall-12F-Osw 34 X 9 276 0.065 5.7 1,561 0.9 0 239 W -GIs-Vector shgc-0.31 0%S (2) 30 0.290 25.2 756 32.7 0 982 j W -GIs-Vector shgc-0.31 0%S 16 0.290 25.2 404 32.8 0 524 N -GIs-Vector shgc-0.31 100%S (2) 30 0.290 25.2 756 9.7 0 290 UP-Ceil-16B-50 28 X 28 784 0.020 1.7 1,364 1.0 0 753 Subtotals for Structure: 7,023 0 3,122 Infil.: Win.: 11.5, Sum.: 6.3 738 1.447 1,068 0.118 97 87 AED Excursion: 989 People: 200 lat/per, 230 sen/per: 4 800 920 Equipment: 0 1,200 Room Totals: 8,091 897 6,318 auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) PymQ th MN 55441 _. System 1 Room Load Summary Htg Min Room Area Sens Htg No Name_ -_ 1--- SF Btuh CFM Zone 1 Lower Level 698 31,532 422 2 Main Level 800 23,111 309 3 Upper Level 784 8,091 108 Ventilation 11,606 System 1 total 2,282 74,340 840 System 1 Main Trunk Size: 10x17 in. Velocity- 791 ft./min Loss per 100 ft.-. 0.101 in.wg Cooling System Summary Cooling Sensible/Latent Tons _ Split Net Required: 2.07 87% / 13% Equipment Data Type: Model: Indoor Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: LJ Natural Gas Furnace 0 AFUE 0 0 Btuh n/a n/a Run Duct Size 3-6 4-7 3-7 Elite Software Development, Inc. Recher HVAC Page 11 Run Cig Clg Min Act Duct Sens Lat Clg Sys Vel Btuh Btuh CFM CFM 384 4,831 269 226 226 385 8,785 103 412 412 369 6,318 897 296 296 1,734 1,939 21,667 3,208 934 934 Sensible Latent Total Btuh -- Btuh - - - BAUIL 21,667 3,208 24,875 Standard Air Conditioner 0 SEER 0 0 Btuh 0 Btuh 0 Btuh auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM m Q) G) z m z O m n z m O Q) m r d z m O T ---4 A r C , oo-o D m z D r- rn m z C) D p -n O T to rn crn z o T '- or- 0 _ o 00 O C z 7 D D , Q m O T T /m m . D -r, z t" i't m O z Z -n n or m m m D m 0 00 m n r- rn GJ N m O N X . 000 -p. O O z m 7(1 O 1 m m O n t U3 z m a7 mM m z m n O O 0 C N O CA) N N N N SIGN m m r H rTi z m m m x m Ov T no A o N m m rm z m QMI HON 4480 86TH STR, LOT 3 - BLOC EDMONSON f MONTICELLO, Mil THIS ARCHITECTURAL PLAN SET AND NOTICE THEEACHINDIVIDUALPAGEINCLUDINGBUTDNOLIMITEDEMENTS REPRESENTED ON PLANELEVATIONDESIGN, DETAILS, INFORMATION, AND CONCEPTS IISOPROPRIE AND AND DEVELOPED FOR THE EXCLUSIVE USE OF JP BROOKS INC. TARY USE AND/OR REPRODUCTION OF ANY PORTION OF THIS PLAN SET IN ANYFORMISSTRICTLYPROHIBITEDWITHOUTEXPRESSEDWRITTENPERMISSIONOF JPBROOKS. VIOLATION WILL BE SUBJECT TO ALL APPLICABLE COPYRIGHT LAWS. WS. BUILDING CODE AND DESIGN DISCLAIMERTHEHOMEPLANREPRESENTEDINTHISPLANSETHASBEENDESIGNTO COMPLYWITHTHE2018INTERNATIONALRESIDENTIALCODE (IRC) AND THE 2020INTERNATIONALENERGYCONSERVATIONCODE (IECC). THE DESIGN OF THISHOMEPLANISDRAWNASACCURATELYASPOSSIBLE, HOWEVER, FINALCONSTRUCTIONMAYDIFFERSLIGHTLYFROMPLANSDUETOSTRUCTURALADJUSTMENTS, FIELD CONDITIONS, OR OTHER DESIGN CONSIDERATIONS. D r C C rn O 00 _ rn m 0 > Covrn r- rn coi5 rn v o z rn rn00rn k OCDnc• rn O cry w 0 ov a C D o, 00 a O WmO 01 0111 O No 4480 86th St NE CITY00 Lot 3 Block 3 - Edmonson Ridge Monticeffo BUILDING SAFETY Builder: JP Brooks Builders 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. Proposed building elevations of lot corners. V Proposed elevations at building corners. Proposed elevations on the side yard swales at the extension of building corners and high points. Proposed and as -built elevations of garage slab and lowest floor on walkouts. Top of curb elevation at the extension of property lines and center of driveway. Proposed elevations and location of any critical drainage ways located on the site natural or man-made) indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Erosion control *Must be installed prior to starting construction and maintained to be compliant with City requirements and project SWPPF Follow City Standard Detail Plate 6006. Proposed driveway location, width at lot line, % of slope. v Show proposed porches, cantilevers, bay windows, and decks (if being constructed). N/A Show individual significant trees 36" DBH (Diameter Breast Height)or larger N/A Existing or proposed retaining wall(s) top and bottom elevations. Show adjacent property topo related to drainage with arrows. Proposed sump pump outlet location on buildinq footprint (natural drainage or piped to curb ). Show any Drain Tile installed in the yard.p p,,, ! ,- nn f . ! h !f City will accept only originals or quality hard copies of the as -built survey and certification of grading. r PROPOSED DING SURVEYi It--, --0 Da'e 2/7/2025 I --- t44110P IP Y2" 44110 I / 55 V j /, % X 964.1 P/D: 155-264-003040 965.E azllr _ % Ref. BPA Job. No. 22-0259.13 E/ev. 967.57 \ / House I w 14490 j ,A) o 6 I V 60 + IP 2 9 A- g64•T O S* 44110 6j` X 8.? • r "A _Lf 6 I s S S8 ?3 /0 £ 12 00 965 770 ' ss 5.33 3 967 4 0 156. 00 ±X _ 43.67 I n 65.5 \o ' IP Y2" v 8 I Tie , 6X 0 30.00 - SQL5.3 12 441/0 I09 N I Pile I N n c X 966.5 X 3! tp _ Proposed 5X 1 Q w House ` Toe I rn I r ` 69. a If4480 File \y i v 39.3 I 2 00 0 nn [ s 964 o^• 1 _ g" a P/D: 155-264-003030 qj I 964. IPropo N 10 a, Area. 7,750 SF. „ V " M V 60 V- V_ i I Drainage and Utility Easements are shown thus: L6 12 6 12 N.T.S. Being 6 feet in width and adjoining lot lines and 12 feet in width and adjoining street lines and rear lot lines as shown on this plot, unless otherwise shown. IDrlvewoy tJ (0.18% Ac.) 61 of % _VI 4S o I8. X- oo Proposed g6 Al * fl6 I X g64 A E - I 25.3 Garage n SS I e 2 S 120.0 0 0 967.9 66 9b 3 - _ L c 965. 1 9 /P Y2" 5.33 Ia. 4Z 00 66.9 0 44110 _ - 9 n - 43.67 I 967,2 ro S 0A - , SaW 2370" E 12100 Gg s68 p t2SLI t lP Ya c6 f 96 969.9 g70' ' a . 64 9% 44//0 F9sw9 ( c, 967.7 /4472 % y I % PID: 155-264-003020 ref. BPA Job. No. 22-0259.1 2L44L- T Y l0 IP Y i 44//0 w OFFSETS ( TOP OF P/PEA PROJECT BENCHMARK.• OS;, f1=967.57(BM) Top of Iron Pipe at Trost NW'ty OSAV2= 965.70 building corner offset OS# 3-966.14 Elevation = 967.57 feet (Plot Datum) OS# 4-968.20 SHEET NO. I Certificate of Survey BOGART, PEDERSON JP Brooks Builders & ASSOCIATES, INC. L3 B3 EDMONSON RIDGE LAND SURVEYING CIVIL ENGINEERING MA Wright County, Minnesota 30761NG FIRSTSTREET, BECKER, MN 55308-9322 TEL: 763-262-8822 FAX: 763-262-8844 0 30' SCALE: I" = 30' I SETBACKS HOUSE TYPE 25' Front Split Level Walkout 7' Side The MAPLEWOOD" 30' Rear ZONING 20' Side Street P.U.D. D& VEWAY AREA TO STREET., 9327- SF. Full Yard - 5,333% S.F. 30' Behind House - 4,486% SF Certificate of Survey for P Brooks Builders Lot 3, Block 3, EDMONSON RIDGE City of Monticello, Wright County, Minnesota Adbkww 4480 86TH STREET ALE MonftW1q, MN 66362 NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/ 29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. Total lot Area - 7,750 4 SF. House Area = 2,260V S.F. Drivewav/Wdk Area = 754 SF. Total Impervious Area - 3,014!4 S.F. (38.9%) FLEV PER GRADING PLAN Pans by Alliant. Garage Floor E/ev - 969.0 Lowest Floor Elevation = 962.0 Rear Elevation = 966.0 L - L ookou t REFERENCE BENCHMARK,• Rim of sanitory manhole on 86th St. N£ near West plot boundary. Elevation = 957. l5 feet (Plot Datum) PROPOSED HOUSE ELEVA TONS Top of Foundation (Hse) Elev = 970.2 Top of Foundation (Gar) Elev = 969.7 Garage Floor Elev = 969.4 Lowest Floor Elev = 966.5 I hereby certify that this survey, plan, or report was prepared by me or under my my direct supervision, and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Signed- Craig A. Wensmann Dote: 2 05/25 Reg. No.47466 DATE: 2/ 05/25 REV DATE DESIGN BY: DRAWN BY: ZH CHECKED BY: CAW/RT DWG FILE: L3 B3 HS FILE NO.: 22-0259,19 LEGEND: 0 Denotes found iron monument 0 Denotes offset iron pipe Denotes set loth x 976. 4 Denotes existing ground elevation Denotes electrical cabinet Denotes electric service T Denotes telephone pedestal LS 44110 Denotes Peter D. Goers, LS 942. Denotes proposed elevation f- - Denotes proposed drainage flow Denotes water service Denotes sanitary service Denotes catch basin Denotes concrete surface Denotes bituminous surface Denotes easement Denotes contour per grading plan Denotes sanitary sewer Denotes waterline SBL - Denotes building setback line Denotes existing odjoiners OHE - Denotes overhead electric Denotes storm sewer DESCRIPTION