2025-00282CITY OF MONTICELLO
505 WALNUT STREET
MONTICELLO, MN 55362-
763) 295-3060 FAX: (763) 295-4404
ADDRESS 4480 86TH ST NE
PIN 155264003030
LEGAL DESC EDMONSON RIDGE
LOT 003 BLOCK 003
PERMIT TYPE BUILDING
PROPERTY TYPE SINGLE FAMILY -DETACHED
CONSTRUCTION TYPE NEW CONSTRUCTION
VALUATION : $ 264,745.02
NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME:
698 SQ FT FINISHED BASEMENT
800 SQ FT UNFINISHED BASEMENT --CRAWL SPACE
800 SQ FT FINISHED MAIN FLOOR
784 SQ FT SECOND FLOOR
36 SQ FT OPEN PORCH
640 SQ FT GARAGE
FIREPLACE: NO
A/C: YES
MECHANICAL: 10
PLUMBING: 20
WATER METER 1 (MAIN) 1.00
WAC UNITS 1.00
APPLICANT
JP BROOKS HOMES
13700 REIMER DRIVE
SUITE 100
MAPLE GROVE, MN 55311-
763) 999-7153
OWNER
LSW INVESTMENTS LLC
4065 CHELSEA RD W
MONTICELLO, MN 55362-
AGREEMENT AND SWORN STATEMENT
I agree that the work will be conducted in conformance with
the ordinances of the City of Monticello and with the
Minnesota State Building Code. I understand that the work
will be in accordance with the plan that has been approved
by the Building Official. I agree that any damage caused to
public property including but not limited to curb, sidewalk,
public utilities and signs will be repaired at my expense.
Applicant _Z-11
Date 3 41 W ! d2 O a,5-
d9;
Bldg Official Date
SAC UNITS
2 0 2 5— 0 0 2 8 2*
DATE ISSUED: 03/14/202-
Permit 4: 2025-00282
BUILDING PERMIT FEE
PLAN REVIEW
STATE SURCHARGE, BLDG VAL
SAC FEE 30%
SAC FEE 70%
WATER ACCESS CHARGE, RESI
COMB CONNECTION FEE / RESI
SEWER / WATER EXCAVATION PERMIT
CONTRACTOR LICENSE VERIFICATION FEE
ASSESSMENT SEARCH FEE
UTILITY LOCATE FEE, RESI
WATER METER I (MAIN)
MN STATE SALES TAX (MTR 1)
TOTAL
Payment(s)
CHECK 22628
2,033.48
1,321.76
132.37
1,449.90
3,383.10
2,153.00
130.00
130.00
5.00
60.00
50.00
475.00
35.03
11,358.64
1 1.358.64
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
CITY OF
Monticeflo
BUILDING SAFETY PERMIT #
505 WALNUT STREET, SUITE 1 MONTICELLO, MN 55362
City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404
BUILDING PERMIT APPLICATION
Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED.
SITE ADDRESS: & I q D 2 &D 5tv-,* 1-i & . ZONED
LEGAL: Lot Block ?j Plat L-J' M 0 1 l c) 1 Ri 8 (y..r
Property Owner Name: JP Brooks Builders Phone: 763-285-4790
Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311
Contractor Name: JP Brooks Builders
State License #: 656554
Address: 13700 Reimer Drive
Eng./Architect Name:
Address:
Plumber Name: Northwoods Plumbing
Address: 30799 73rd Street
Mechanical Name: Recher HVAC
Address: 1125 Mississippi Drive North
Twe of Work
L( New
Addition
Alteration
Repair
Move
Other
Phone: 763-285-4790
E-Mail: shelly@jpbrooks.com
City: Maple Grove State: MN Zip: 55311
City:
City: Pierz
City: Champlin
T pe of Construction
Single Family
Duplex
Multi -Family
Commercial
Industrial
Other
Phone:
State: Zip:
Phone: 763-717-8757
State: MN Zip: 56364
Phone: 612-802-6525
State: MN Zip: 55316
Building Informati"on,.
Use of building (JQAAs (I
of stories
Floor area sq. ft. 01 c) S
Estimated value 2Uy1)'-V5
of construction $ 7
D scription of work:
1
V
I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I
agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota;
and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will
be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public pro er including but
not limited to curb, sidewalk, public utilities and signs will be repaired at my expense.
G
SEE BAf1R PT,T 1 R{G
c l r) Vi C
AND MECHANICAL INFO.
Applicant Signa e
T
Application Date
APPLICANT: Please show_ fixtures that are applicable.
Fi e Suppression : (if applicable) Plumbinz: (if applicable) Mechanical. (if applicable)
No. ixture Tvpe No. Fixture Tvve No. Fixture Tvve
kler Heads Water Closet (toilet) I Furnace
Oth Special FS Device
fLq
Z Bathtub 1 1 Gas Meter
5' Lavatory (wash basin) Range Hood
a Z Shower Gas Range
I 1 Kitchen Sink C Water Heater
Dishwasher Air Conditioning
Laundry Tub Mech. Fireplace
1 Clothes Washer L4 Bathroom(s) Exhaust Fan
Fire Alarm: (if applicable) I 1 Water Heater 1 Air Exchanger
Urinal Dryer
No. Fixture Tvve Drinking Fountain Gas Opening w/o Fixture
Floor Drain
J # of Devices Slop Sink
Other IL Outside Faucet
Z TOTAL
Future Owner Information:
Name:
Address:
D TOTAL
FOR CITY USE ONLY
Tree Ordinance Handout Yes No
Other Handouts Yes No
City: ADDITIONAL INFORMATION:
Valuation: "l --) 4 b
State: Zip: Construction Type: V b
Occupancy Group: 'Qe-,
Phone #: Division:
Square Footage: ZztZ.
of Stories: —
of Residential Units:
Maximum Occupancy:
Fire Sprinklers: Yes .A No
Off -Street Parking Covered: 3
Off -Street Parking Uncovered:
4j., t
0 Z ZBuildingOfficial / I RDZ 5-
BPT: / /
Monticello 2025 Residential Building Permit Calculator
Address: 4480 86th St NE
Legal: Lot 3 Block 3 Edmonson Ridge
1 = Yes 0 = No
New Residence: I House Type: Multi Level
1 = Yes 0 = No 1 = Yes 0 = No
Permit Applicant: Contractor: 1 Plan Review: I
JP Brooks Owner: 0 Master Plan: 0
Master Plan Review = 25% of Building Permit Fee)
I Ise June 016 Valuation Factor TOTAL
Crawl Space 800 S 15.27 12,216.00
Unfinished Basement Area 0 $ 16.50
Finished Basement Area 698 $ 44.05 30,746.90
Main/First Floor Area 800 $ 125.00 100,000.00
Second Floor Area 784 $ 115.00 90,160.00
Detached Garage 0 $ 60.00
Attached Garage 640 $ 47.33 30,291.20
Garage Conversion to Living Space 0 $ 47.44
CarpordGazebo 0 $ 30.90
Pole Barn 0 $ 19.03
Shed - greater than 200 SF 0 $ 40.00
Lean -to -Shed 0 $ 13.25
Basement Finish Only 0 $ 16.00
Remodeled Area 0 $ 17.39
Porch (open) 36 $ 36.97 1,330.92
Porch (3-Season) 0 $ 60.00
Porch (3-Season on Existing Deck) 0 $ 55.00
Porch (Screen Porch/Breezeway) 0 $ 58.48
Solarium 0 $ 94.90
Deck 0 $ 20.00
Deck (Screen In & Roof Over Existing) 0 $ 29.80
In -Ground Pool 0 $ 23.18
Above -Ground Pool 0 $ 11.31
Fireplace - Mechanical/Gas 0 $ 4,892.50
Fireplace - Masonry 0 $ 22,660.00
Elevator/Lift/Other 0
CALCULATED BUILDING VALUATION S 264,745.02
1 = Yes 0 = No
Water Hook-up I
Sanitary Sewer Hook-up I
FEES:
BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% $ 2,032.82
PLAN CHECK 1,321.33
CONTRACTOR LICENSE VERIFICATION 5.00
STATE SURCHARGE 132.37
SUBTOTAL 3,491.52
SEWER FEE [SAC] 4,833.00
WATER FEE ]WAC] 2,153.00
WATER / SEWER CONNECTION FEE 130.00
SEWER/WATER EXCAVATION PERMIT FEE 130.00
ASSESSMENT SEARCH 60.00
UTILITY LOCATES 50.00
5/8" WATER METER & SALES TAX 510.03
SUBTOTAL 7,866.03
TOTAL FEES CALCULATED 11.357.55
Escrow Amount - (Winter Only)
TOTAL AMOUNT TO BE PAID TO CITY 119357.55
CITY OF
i/Ionticello
BUILDING SAFETY
RESIDENTIAL PLANS EXAMINING REPORT
505 Walnut Street, Suite 1
MONTICELLO, MN 55362
Date: 2/6/2025
Contractor:
City Hall (763) 295-2711
Building Inspections (763) 295-3060
JP Brooks
4480 86th Street NE
JP Brooks
13700 Reimer Drive
Maple Grove, MN 55311
Telephone: 763-285-4790
BASIC PROJECT DESCRIPTION:
Three level split with electric
fireplace and
luxury suite
Finished lower level
29282 Sq ft Finished
1 1 Page
Bldg Building, Mechanical &Plumbing Bob Ferguson — Chief Building Official 763) 271-3214
Bob.Fer ,uson a MonticelloMN.g
Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908
Wayne.Kalla(a MonticelloMN.Pov
Mark Gerber — Inspector / Plan Reviewer
Mark.Gerber(aa;MonticelloMN. ov 763) 271-3222
Amy Biren — Building Permit Technician 763) 295-3060
buildingdepartmentA,MonticelloMN.gov
review Electrical Bill Husom — Electrical Inspector (612)490-0488
outside Office Hrs: 7-8:30am
of city Pen -nits I Minnesota Department of Labor and Industry
mn.v-ov )
910 —181h St SE, Buffalo, MN 55313
CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-3224
Angela.Schumami(u gov
Bob Ferguson — Zoning Administrator 763) 271-3214
ob.F r uson a Monti ell N. ov
Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer (763)-271-3271
PW Utilities Matt. Leonard(c-t'MonticelloMN.cOV
Ryan Melhouse — Project Engineer (763) 271-3227
Rvan.Melhouse((i.)MonticelloMN.cov
Mario Frucci — Engineering Technician
Mario. Frucci(rtMonticelloMN.cov (763) 271-3213
Mat Stang - Water & Sewer Superintendent (763) 271-3274
Mat.Stane(a,MonticelloMN.cov
The plan review accomplished as indicated in this record is limited to those code sections specifically
identified herein. This record references commonly applicable code sections. It does not reference all code
provisions which may be applicable to specific buildings. This record is designed to be used only by those
who are knowledgeable and capable of exercising competent judgment in evaluating construction
documents for code compliance.
Page
The following notations refer to design submittal documents as presented in application for a building permit. This report is
not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota
Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of
the Building Plans and Specifications.
This review is for Buildine Construction Permit review onlv. All other reviews will be conducted with
their respective permit applications. See note #1 below.
PLAN
NO. DEPT SHEET/ CODE
SECTION
COMMENTS
SPEC.
SECTION
1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area
note
2
bldg n/a general Building Official review and authorization required prior to changes, modifications,
note or alterations.
3
bldg n/a general
1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has
note been issued.
4
bldg n/a general Final Building, Plumbing, and Heating inspections must be completed prior to
note occupancy. Owner or contractor must be present for final building inspection.
5 bldg n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction.
note
6
bldg n/a general Separate applications and permits Required for Sewer / Water Connection, Heating
note A/C Systems, Plumbing, Fire Alarm Systems.
bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted
7 note Subp 15 in a permanently visible location prior to final inspection
N1101.8)
Bldg MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F
8 299F .50 50
R315
bldg Buildings must be constructed per current building codes. 2020 MN State Building
Code including:
n/a general
0 2020 MN Residential Code
9
note
MR 1300 2023 National Electrical Code
2020 MN Plumbing Code
2020 MN Mechanical Code
2020 MN Fire Code
bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive.
10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure
treated lumber must be approved for such use.
11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans
12
bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are
note installed.
13
bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans
note for framing inspection.
14
bldg n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical
note work.
15 bldg Maintain 6" Earth to wood separation
3 1 Page
PLAN
NO. DEPT
SHEET/
SPEC.
CODE
SECTION
COMMENTS
SECTION
Eng Erosion Control Required: Install erosion control per proposed survey prior to
16 foundation inspection. Rock construction entrance and site perimeter controls such
as silt fence are required. Maintain erosion controls until landscaping is completed.
bldg Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend
up from the radon control system's collection point to a point terminating a
minimum of 12" above the roof. The vent pipe shall be located at least 10' away
17 from any window or other opening into the conditioned spaces of the building. Vent
pipes routed through unconditioned spaces shall be insulated with a minimum of R-4
insulation. Vent pipes within the conditioned envelope of the building shall not be
insulated.
18
bldg
R312 2 Window Fall Protection Required for all windows 6' above grade with sill height of
less than 24", maximum opening must be less than 4".
19 bldg WARNING: Call Before You Dig! Gopher State one 651-454-0002
20
bldg. Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not
Exceed 3 Air Exchanges Per Hour.
21 bldg Flash between House and Stoop.
22 bldg R319.1 Install House Numbers: 4" minimum, visible from street.
23
bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber /
damper areas are exposed.
24 bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord.
25
bldg
R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic.
Close horizontal to vertical penetrations.
26
bldg
R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly
blocked and carried continuously to foundation.
27
bldg Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to
daylight; schedule 40 pipe required).
28 bldg R402.4.1.1 Hardboard Backer Required behind tub / shower.
29 bldg Seal and Secure Sump Pump Basket Cover.
30 bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces).
31
bldg
R405.2.3 Fain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install
flexible hose connection extending to drainage area away from the foundation wall.
32
bldg R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for
Subpart 6 future active radon ventilation system.
bldg Radon gas vent pipes shall be provided with space around the vent pipe for future fan
33 R 1303.2402
installation. The space required for the future fan installation shall be a minimum of
24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum
distance of 3 vertical feet.
34 hh k R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation.
35
bldg
R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss
manufacture.
4 1 Page
PLAN
NO. DEPT SHEET/ CODE
SPEC. SECTION
COMMENTS
SECTION
bldg R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to
36 MN Res.Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation.
code
37
bldg
R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception:
Detached Accessory Buildings)
Bldg 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2nd course of
38 R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2
anchors per plate, 1 anchor within 1' of each end.
Exterior non -draining foundation insulation requirements: have a rigid, opaque, and
weather -resistant covering to prevent degradation of the insulation's thermal
39 bldg R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation
and extend a minimum of 6" below grade. The insulation and protective covering
system shall be flashed in accordance with IRC section R703.8.
DRIVEWAY REQUIREMENTS:
40 zoning R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to
a width Not to Exceed 28 Ft. and the Public Street.
5 1 Page
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
Date Certificate Post
panel.
Mailing Address oft pw 1fiR or Dwelling Unit
LALA S 0 K(0 'S
Name of Residential ConbmctorJP Brooks
THERMAL ENVELOPE
Insulation location
Below Entire Slab
Foundation Wall
Perimeter of Slab on Grade
Rim Joist (1st Floor)
Rim Joist (2nd Floor+)
Wall
Ceiling, flat
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Describe other insulated areas
Building envelope airtightness:
0
0
a) n
F
m
TO
R-15
R-15
R-30
R-30
R-21
R-48
R-46
R-30
NA
Windows & Doors
Average U-Factor (excludes skylights and one door) U:
Solar Heat Gain Coefficient (SHGC):
MECHANICAL SYSTEMS
CNTJV\k,
MN License Number
BC 686554
Place your
logo here
RADON CONTROL SYSTEM
Type: Check All That Apply 0 Passive (No Fan)
With fian and monometer
r_ ElActiveorother system monitoring device)
Location (or future location) of Fan:
m
V c R 0. m
Attic
3 V, U °'
Q. 0
Lit C1 n m C
zCUro to
to 0 o to
4. o a' E E m o
a
z
N
U_
W
U_
to C0
ti
C m 5
Other Please Describe Here
Poly Banter
Exterior and lntedor as dictated by code
Interior of Foundation Wet!
Duct system airtightness: I NA
Heating or Cooling Ducts Outside Conditioned Spaces
Not applicable, all ducts located in conditioned space
R value
Appliances Heating System
Domestic Water
Heater
Nat. Gas Nat. GasFuelType
Bryant RichmondManufacturer
iRD'S A 1_A70M 1Model
Input in
BTUs
Capacity
InIn Gallons:150RatingorSizett)40k
AFUE or
Efficiency HSPF%, 96.2 90
Heating Loss Heating Gain
Residential Load Calculatit '
3 t O1
I MECHANICAL VENTILATION SYSTEM
Make-up Air Select a Type
Cooling System Not required per meth. code
Elect. Passive
Bryant Powered
u
Interlocked with exhaust device.
BA013NR030BNG Describe:
Output r Other, describe:
in Tons:
SEER Location of duct orsystem:
EER 113
Cooling Load
I c Cfm's
round duct OR
metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Select Type
i Heat Recover Ventilator (HRV) Capacity in cfms: Low: lHigh: High:
Energy Recover Ventilator (ERV) Capacity in cfmsLow: so 1130 Balanced
Ventilation capacity in cfms: Location
offan(s), describe: I Bathrooms and Laundry Capacity,
continuous ventilation rate In cfms: so-1s0 Total
ventilation Cintermittent + continuous) rate in alms: 270 Combustion
Air Select Type 1
Not required per meth. code Passive
Other,
describe: Location
of duct or system: Mechanical
Room Cfm'
s s "
round duct OR metal
duct Builders
Associaton of Minnesota version 101014
Recher HVAC
HVAC Load Calculations
for
4480 86th Street
Prepared By:
Friday, March 7, 2025
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
PlymoOh—_MN 55441
Project Report
General Project Information
Project Title. Recher HVAC
Project Date: Friday, January 31, 2025
Client Name: 4480 86th Street
Design Data
Reference City: Minneapolis/St. Paul AP, Minnesota
Building Orientation: Front door faces East
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation- 834 ft.
Altitude Factor: 0.970
Elite Software Development, Inc.
Recher HVAC
Page 2
Outdoor
Dry Bulb
Outdoor
Wet Bulb
Outdoor Indoor Indoor Grains
Winter: -15 15
RLJHm
n/a
Rel.Hum
n/a
Dry Bulb
72
Difference
n/a
Summer: 88 71 44% 50% 75 24
Check Figures
Total Building Supply CFM: 934
Square ft. of Room Area: 2,282
Volume (ft3): 17,324
Building Loads
Total Heating Required Including Ventilation Air:
Total Sensible Gain:
Total Latent Gain:
Total Cooling Required Including Ventilation Air:
CFM Per Square ft.: 0.409
Square ft. Per Ton: 1,101
74,340 Btuh 74.340 MBH
21,667 Btuh 87 %
3,208 Btuh 13 %
24,875 Btuh 2.07 Tons (Based On Sensible + Latent)
Notes__
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plymouth, MN 55441
Miscellaneous Report
System 1 House Outdoor Outdoor Outdoor
Input Data Dry Bulb Wet Bulb Rel.Hum
Winter: 15 15 100%
Summer: 88 71 44%
Duct § inglnputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 0 ft./min 0 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Infiltration Specified:
Winter
0.110 AC/hr
Summer
0.060 AC/hr
32 CFM 17 CFM
Infiltration Actual: 0.110 AC/hr 0.060 AC/hr
Above Grade Volume: X 17,324 Cu.ft. X 17,324 Cu.ft.
1,906 Cu.ft./hr 1,039 Cu.ft./hr
Total Building Infiltration:
X 0.0167
32 CFM
X 0.0167
17 CFM
Total Building Ventilation: 125 CFM 125 CFM
Elite Software Development, Inc.
Recher HVAC
Page 3
Indoor Indoor Grains
Rel.Hum Dry Bulb Difference
n/a 72 n/a
50% 75 23.51
System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.110 AC/hr (32 CFM), Construction: Tight
Summer Infiltration Specified: 0.060 AC/hr (17 CFM), Construction: Tight
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plymouth MN_55441
Load Preview Report
Scope
Buildinq
Svstem 1
Ventilation
Zone 1
1-Lower Level
2-Main Level
3-Upper Level
Elite Software Development, Inc.
6 Recher HVAC
Pie 4
Nei. ft.; Se n La Net Se
Sys
Htg
Sy
Clg
Sys
Ac Duc
Ton /Tor Are Gai Gai Gair Loss CFM, CFM CFM Size
2.07 1,101 2,282 21,667 3,208 24,875 74,340 840 934 934
2.07 1,101 2,282 21,667 3,208 24,875 74,340 840 934 934 10x1
1,734 1,939 3,673 11,606
2,282 19,933 1,269 21,202 62,734 840 934 934 10x1 i
698 4,831 269 5,100 31,532 422 226 226 3--6
800 8,785 103 8,888 23,111 309 412 412 4-7
784 6,318 897 7,215 8,091 108 296 296 3--7
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plymouth, MN 55441
Duct Size Pre vie w
Room or Minimurr
Duct Name SourceI Velocit`
Svstem 1
Supply Runouts
Zone 1
1-Lower Level Built -In 0
2-Main Level Built -In 0
3-Upper Level Built -In 0
Other Ducts in System 1
Supply Main Trunk Built -In 0
Svstem 1
Heating Flow: 840
Cooling Flow: 934
Elite Software Development, Inc.
Recher HVAC
Page 5
750 0.01 0.1 384.2
750 0.01 0.1 385
750 0.01 0.1 369.2
900 0.003 0.1 791
Summary
clg I Act. I Duct
422 _ 226 3--6
309= 412 4--7
108 _ 296 3--7
840934 10x1fj auerfiles\
FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steel (Plymouth) Recher HVAC
Plymouth MN 55441 Page_6_.
Total Building Summary Loads
Component Area Sen Lat Sen Total
description_ Quan Loss Gain Gain Gain
Vector: Glazing -Vector Winows , U-value 0.29, SHGC 256 6,459 0 7,275 7,275
0.31
11 P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292
15BO-10sf-8: Wall -Basement, , R-10 board insulation to 624 2,714 0 0 0
floor, no interior finish, 8' floor depth, U-value 0.05
12F-Osw.- Wall -Frame, R-21 insulation in 2 x 6 stud 1740 9,839 0 1,504 1,504
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
15BO-10sf-4- Wall -Basement, , R-10 board insulation to 136 639 0 0 0
floor, no interior finish, 4' floor depth, U-value 0.054
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 1584 2,756 0 1,521 1,521
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
22A-ph: Floor -Slab on grade, No edge insulation, no 194 22,920 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil, U-value 1.358
20P-0c: Floor -Over open crawl space or garage, Passive, 400 13,398 0 1,232 1,232
no insulation, carpet or hardwood, U-value 0.385
Subtotals for structure: 59,785 0 11,824 11,824
People: 5 1,000 1,150 2,150
Equipment: 0 3,600 3,600
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 32, Summer CFM: 17 2,949 269 240 509
Ventilation: Winter CFM: 125, Summer CFM: 125 11,606 1,939 1,734 3,673
Exhaust: Winter CFM: 125, Summer CFM: 125
AED Excursion: 0 0 3,119 3,119
Total Building Load Totals: 74,340 3,208 21,667 24,875
Check Figures
Total Building Supply CFM: 934 CFM Per Square ft.: 0.409
Square ft. of Room Area: 2,282 Square ft. Per Ton: 1,101
Volume (ft'): 17,324
Building _Loads
Total Heating Required Including Ventilation Air: 74,340 Btuh 74.340 MBH
Total Sensible Gain: 21,667 Btuh 87 %
Total Latent Gain: 3,208 Btuh 13 %
Total Cooling Required Including Ventilation Air: 24,875 Btuh 2.07 Tons (Based On Sensible + Latent)
motes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
Plvmouth. MN 55441
Building Pie Chart
Floor 49%
Elite Software Development, Inc.
Recher HVAC
Paae 7
Ventilation 16%
Infiltration 4%
Door 1 %
Glass 9%
VVall 18%
Roof 4%
Floor 5%
Roof 6% AED Excursion 13%
Wall 6%
Glass 29%
Door 1 % People 9%
Ventilation 15%
Infiltration 2%
Equipment 14%
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steel (Plymouth) Recher HVAC
Plymouth, MN 55441 - Paae 8
Detailed Room Loads
T
Room 1 - Lower Level (Average Load Procedure I
General —
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 26.8 ft. System Number: 1
Room Width: 26.0 ft. Zone Number: 1
Area: 697.8 sq.ft. Supply Air: 226 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.4 AC/hr
Volume: 5,583 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 3 Actual Winter Vent.: 63 CFM
Runout Air: 75 CFM Percent of Supply.: 28 %
Runout Duct Size: 6 in. Actual Summer Vent.: 30 CFM
Runout Air Velocity: 384 ft./min. Percent of Supply: 13 %
Runout Air Velocity: 384 ft./min. Actual Winter Infil.: 8 CFM
Actual Loss: 0.093 in.wg./100 ft. Actual Summer Infil.: 4 CFM
Item Area U- Htg Sen Clg Lat Sen
Description Quantity Value HTM - - - Loss HTM_ Gain Gain
E -Wall-15BO-10sf-8 48 X 8 384 0.050 4.4 1,670 0.0 0 0
S -Wall-15BO-10sf-8 30 X 8 240 0.050 4.4 1,044 0.0 0 0
W -Wall-12F-Osw 48 X 8 322 0.065 5.7 1,821 0.9 0 278
N -Wall-15BO-10sf-4 34 X 4 136 0.054 4.7 639 0.0 0 0
N -Wall-12F-Osw 34 X 4 118 0.065 5.7 667 0.9 0 102
W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 32.7 0 1,375
W -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 32.8 0 655
N -GIs-Vector shgc-0.31 100%S 18 0.290 25.2 454 9.7 0 174
Floor-22A-ph 194 ft..Per. 194 1.358 118.1 22,920 0.0 0 0
Subtotals for Structure: 30,780 0 2,584
InfiI.: Win.: 8. 1, Sum.: 4.4 520 1.446 752 0.117 69 61
AED Excursion: 756
People: 200 lat/per, 230 sen/per: 1 200 230
Equipment: 0 1,200
Room Totals: 31,532 269 4,831
i
i
I
I
auerfiles\FILES ...\Recher HVAC 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steel (Plymouth) Recher HVAC
Plymouth, MN 55441
Detailed Room Loads -Room 2 -Main Level (Average Load Procedure)
General
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 28.6 ft. System Number: 1
Room Width: 28.0 ft. Zone Number: 1
Area: 800.0 sq.ft. Supply Air: 412 CFM
Ceiling Height: 10.0 ft. Supply Air Changes: 3.1 AC/hr
Volume: 8,000 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 4 Actual Winter Vent.: 46 CFM
Runout Air: 103 CFM Percent of Supply.: 11 %
Runout Duct Size: 7 in. Actual Summer Vent.: 55 CFM
Runout Air Velocity: 385 ft./min. Percent of Supply: 13 %
Runout Air Velocity: 385 ft./min. Actual Winter Infil.: 12 CFM
Actual Loss: 0.075 in.wg./100 ft. Actual Summer Infil.: 7 CFM
Item Area U- Htg Sen Clg Lat Se
Description Quantity Value HTM Loss HTM Gain G_ aiI ,
E -Wall-12F-Osw 24 X 10 186 0.065 5.7 1,052 0.9 0 161
S -Wall-12F-Osw 30 X 10 300 0.065 5.7 1,696 0.9 0 259
W -Wall-12F-Osw 24 X 10 152 0.065 5.7 860 0.9 0 131
E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146
E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146
E -GIs-Vector shgc-0.31 0%S 12 0.290 25.2 303 32.8 0 393
W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 32.7 0 1,375
W -GIs-Vector shgc-0.31 0%S (2) 26 0.290 25.2 656 32.8 0 852
W -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 32.8 0 655
UP-Ceil-1613-50 28.6 X 28 800 0.020 1.7 1,392 1.0 0 768
Floor-20P-Oc 20 X 20 400 0.385 33.5 13,398 3.1 0 1,232
Subtotals for Structure: 21,982 0 6,118
Infil.: Win.: 12.2, Sum.: 6.6 780 1.447 1,129 0.118 103 92
AED Excursion: 1,375
Equipment: 0 1,200
Room Totals: 23,111 103 8,785
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Auer Steei (Plymouth) Recher HVAC
Plymouth, MN 5_5441 _ Page 10
Detailed Room Loads - Room 3 - Upper Level (Average Load Procedure)
General
Calculation Mode: Htg. & clg. Occurrences: 1
Room Length: 28.0 ft. System Number: 1
Room Width: 28.0 ft. Zone Number: 1
Area: 784.0 sq.ft. Supply Air: 296 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.5 AC/hr
Volume: 7,056 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 3 Actual Winter Vent.: 16 CFM
Runout Air: 99 CFM Percent of Supply.: 5
Runout Duct Size: 7 in. Actual Summer Vent.: 40 CFM
Runout Air Velocity: 369 ft./min. Percent of Supply: 13
Runout Air Velocity: 369 ft./min. Actual Winter Infil.: 12 CFM
Actual Loss: 0.069 in.wg./100 ft. Actual Summer Infil.: 6 CFM
Item Area U- Htg Sen Clg Lat Se
Description Quantity Value HTM - Loss HTM Gain Gai
E -Wall-12F-Osw 24 X 9 216 0.065 5.7 1,221 0.9 0 187
W -Wall-12F-Osw 24 X 9 170 0.065 5.7 961 0.9 0 147
N -Wall-12F-Osw 34 X 9 276 0.065 5.7 1,561 0.9 0 239
W -GIs-Vector shgc-0.31 0%S (2) 30 0.290 25.2 756 32.7 0 982 j
W -GIs-Vector shgc-0.31 0%S 16 0.290 25.2 404 32.8 0 524
N -GIs-Vector shgc-0.31 100%S (2) 30 0.290 25.2 756 9.7 0 290
UP-Ceil-16B-50 28 X 28 784 0.020 1.7 1,364 1.0 0 753
Subtotals for Structure: 7,023 0 3,122
Infil.: Win.: 11.5, Sum.: 6.3 738 1.447 1,068 0.118 97 87
AED Excursion: 989
People: 200 lat/per, 230 sen/per: 4 800 920
Equipment: 0 1,200
Room Totals: 8,091 897 6,318
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
Rhvac - Residential & Light Commercial HVAC Loads
Auer Steel (Plymouth)
PymQ th MN 55441 _.
System 1 Room Load Summary
Htg Min
Room Area Sens Htg
No Name_ -_
1---
SF Btuh CFM
Zone
1 Lower Level 698 31,532 422
2 Main Level 800 23,111 309
3 Upper Level 784 8,091 108
Ventilation 11,606
System 1 total 2,282 74,340 840
System 1 Main Trunk Size: 10x17 in.
Velocity- 791 ft./min
Loss per 100 ft.-. 0.101 in.wg
Cooling System Summary
Cooling Sensible/Latent
Tons _ Split
Net Required: 2.07 87% / 13%
Equipment Data
Type:
Model:
Indoor Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity:
Latent Capacity:
LJ
Natural Gas Furnace
0 AFUE
0
0 Btuh
n/a
n/a
Run
Duct
Size
3-6
4-7
3-7
Elite Software Development, Inc.
Recher HVAC
Page 11
Run Cig Clg Min Act
Duct Sens Lat Clg Sys
Vel Btuh Btuh CFM CFM
384 4,831 269 226 226
385 8,785 103 412 412
369 6,318 897 296 296
1,734 1,939
21,667 3,208 934 934
Sensible Latent Total
Btuh -- Btuh - - - BAUIL
21,667 3,208 24,875
Standard Air Conditioner
0 SEER
0
0 Btuh
0 Btuh
0 Btuh
auerfiles\FILES ...\Recher HVAC - 4480 86th Street.rh9 Friday, March 7, 2025, 10:56 AM
m
Q)
G)
z
m
z
O
m
n
z
m
O
Q)
m
r
d
z
m
O
T ---4 A r C , oo-o
D m z D r- rn m z
C) D p -n O T
to
rn
crn
z o T '- or-
0 _ o 00 O C
z 7 D
D , Q m O
T
T /m
m . D -r, z t" i't
m O z Z -n
n or
m m m
D m 0 00
m n
r- rn
GJ N
m
O N X . 000 -p.
O
O
z
m
7(1
O
1
m
m
O
n
t
U3
z
m
a7
mM
m
z
m
n
O O
0
C N
O CA)
N N
N N
SIGN
m
m
r
H
rTi z
m
m
m x
m
Ov
T
no
A
o
N
m
m rm
z
m
QMI HON
4480 86TH STR,
LOT 3 - BLOC
EDMONSON f
MONTICELLO, Mil
THIS ARCHITECTURAL PLAN SET AND NOTICE
THEEACHINDIVIDUALPAGEINCLUDINGBUTDNOLIMITEDEMENTS REPRESENTED ON
PLANELEVATIONDESIGN, DETAILS, INFORMATION, AND CONCEPTS IISOPROPRIE
AND
AND DEVELOPED FOR THE EXCLUSIVE USE OF JP BROOKS INC.
TARY
USE AND/OR REPRODUCTION OF ANY PORTION OF THIS PLAN SET IN ANYFORMISSTRICTLYPROHIBITEDWITHOUTEXPRESSEDWRITTENPERMISSIONOF JPBROOKS. VIOLATION WILL BE SUBJECT TO ALL APPLICABLE COPYRIGHT LAWS. WS.
BUILDING CODE AND DESIGN DISCLAIMERTHEHOMEPLANREPRESENTEDINTHISPLANSETHASBEENDESIGNTO COMPLYWITHTHE2018INTERNATIONALRESIDENTIALCODE (IRC) AND THE 2020INTERNATIONALENERGYCONSERVATIONCODE (IECC). THE DESIGN OF THISHOMEPLANISDRAWNASACCURATELYASPOSSIBLE, HOWEVER, FINALCONSTRUCTIONMAYDIFFERSLIGHTLYFROMPLANSDUETOSTRUCTURALADJUSTMENTS, FIELD CONDITIONS, OR OTHER DESIGN CONSIDERATIONS.
D
r C C
rn O 00 _ rn m
0 > Covrn r-
rn coi5
rn
v
o z rn rn00rn k OCDnc• rn
O cry
w
0 ov
a C
D
o,
00
a O
WmO 01
0111 O
No
4480 86th St NE
CITY00 Lot 3 Block 3 - Edmonson Ridge
Monticeffo
BUILDING SAFETY Builder: JP Brooks Builders
505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404
CITY OF MONTICELLO
PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST
Prior to excavation and construction, the permittee shall submit to the City of Monticello
through certificate of survey that the proposed construction is in compliance with all land use,
zoning, conditional use, or planned use as part of the building permit application. The
certificate of survey shall be signed by a registered Minnesota land surveyor.
The signed certificate of survey shall contain at a minimum the following information:
Indicate permanent iron monuments at each lot corner.
Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks,
lakes, and Type 4 and 5 wetlands.
Proposed building elevations of lot corners.
V Proposed elevations at building corners.
Proposed elevations on the side yard swales at the extension of building corners and
high points.
Proposed and as -built elevations of garage slab and lowest floor on walkouts.
Top of curb elevation at the extension of property lines and center of driveway.
Proposed elevations and location of any critical drainage ways located on the site
natural or man-made) indicated with drainage arrows and percentage of slope.
Label all adjacent street and railroad right-of-way.
Erosion control *Must be installed prior to starting construction and maintained to be compliant with
City requirements and project SWPPF Follow City Standard Detail Plate 6006.
Proposed driveway location, width at lot line, % of slope.
v Show proposed porches, cantilevers, bay windows, and decks (if being constructed).
N/A Show individual significant trees 36" DBH (Diameter Breast Height)or larger
N/A Existing or proposed retaining wall(s) top and bottom elevations.
Show adjacent property topo related to drainage with arrows.
Proposed sump pump outlet location on buildinq footprint (natural drainage or piped to
curb ). Show any Drain Tile installed in the yard.p p,,, ! ,- nn f . ! h !f
City will accept only originals or quality hard copies of the as -built survey and
certification of grading.
r PROPOSED DING SURVEYi
It--, --0 Da'e 2/7/2025
I --- t44110P
IP Y2"
44110
I / 55
V
j /, % X
964.1
P/D: 155-264-003040
965.E azllr _ % Ref. BPA Job. No. 22-0259.13
E/ev. 967.57 \ / House
I
w
14490 j ,A)
o
6 I
V
60 + IP 2
9
A- g64•T O
S* 44110
6j`
X 8.? • r "A _Lf 6 I
s S S8 ?3 /0 £ 12 00 965 770 '
ss 5.33
3 967 4 0 156. 00 ±X _ 43.67 I
n 65.5 \o ' IP Y2"
v 8 I Tie , 6X 0 30.00 - SQL5.3
12
441/0
I09
N I Pile I N n c X 966.5 X 3!
tp _ Proposed 5X 1 Q w
House ` Toe I rn
I
r `
69. a If4480 File \y i v
39.3 I 2 00 0 nn [ s 964
o^• 1 _ g" a P/D: 155-264-003030 qj I 964.
IPropo N 10 a, Area. 7,750 SF. „
V "
M
V
60
V-
V_
i
I
Drainage and Utility Easements are
shown thus:
L6
12
6
12
N.T.S.
Being 6 feet in width and adjoining lot
lines and 12 feet in width and adjoining
street lines and rear lot lines as shown
on this plot, unless otherwise shown.
IDrlvewoy tJ (0.18% Ac.) 61 of % _VI 4S o I8. X- oo Proposed g6 Al * fl6 I X g64 A E - I 25.3 Garage
n SS
I
e
2 S
120.0 0 0 967.9
66
9b 3 - _ L c 965. 1
9 /P Y2" 5.33 Ia. 4Z 00 66.9 0
44110 _ - 9 n - 43.67 I
967,2
ro
S 0A - , SaW 2370" E 12100
Gg s68 p t2SLI t lP Ya
c6 f
96
969.9 g70' '
a . 64 9%
44//0
F9sw9 (
c,
967.7 /4472 %
y
I % PID: 155-264-003020
ref. BPA Job. No. 22-0259.1
2L44L-
T
Y
l0
IP Y i 44//0 w
OFFSETS (
TOP OF P/PEA PROJECT BENCHMARK.• OS;,
f1=967.57(BM) Top of Iron Pipe at Trost NW'ty OSAV2=
965.70 building corner offset OS#
3-966.14 Elevation = 967.57 feet (Plot Datum) OS#
4-968.20 SHEET
NO. I
Certificate of Survey BOGART, PEDERSON JP
Brooks Builders & ASSOCIATES, INC. L3
B3 EDMONSON RIDGE LAND SURVEYING CIVIL
ENGINEERING MA
Wright
County, Minnesota 30761NG FIRSTSTREET, BECKER, MN 55308-9322 TEL:
763-262-8822 FAX: 763-262-8844 0
30' SCALE:
I" = 30' I
SETBACKS
HOUSE TYPE 25'
Front Split Level Walkout 7'
Side The MAPLEWOOD" 30'
Rear ZONING 20'
Side Street P.U.D. D&
VEWAY AREA TO STREET., 9327-
SF. Full
Yard - 5,333% S.F. 30'
Behind House - 4,486% SF Certificate
of Survey for P
Brooks
Builders Lot 3,
Block 3, EDMONSON RIDGE City of
Monticello, Wright County, Minnesota Adbkww 4480
86TH STREET ALE MonftW1q, MN 66362 NO EXCAVATION
OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN
IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST
FLOOR
ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND
DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE
SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO
US. CONTRACTOR TO
DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST
FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE.
PRIOR TO
ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO
VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND
UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN
HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/
29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. Total lot
Area - 7,750 4 SF. House Area =
2,260V S.F. Drivewav/Wdk
Area = 754 SF. Total Impervious
Area - 3,014!4 S.F. (38.9%) FLEV PER
GRADING PLAN Pans by
Alliant. Garage Floor
E/ev - 969.0 Lowest Floor
Elevation = 962.0 Rear Elevation =
966.0 L - L
ookou t REFERENCE BENCHMARK,•
Rim of
sanitory manhole on 86th St. N£ near
West plot boundary. Elevation = 957.
l5 feet (Plot Datum) PROPOSED HOUSE
ELEVA TONS Top of
Foundation (Hse) Elev = 970.2 Top of
Foundation (Gar) Elev = 969.7 Garage Floor
Elev = 969.4 Lowest Floor
Elev = 966.5 I hereby
certify that this survey, plan, or report was
prepared by me or under my my direct
supervision, and that I am a duly Licensed
Land Surveyor under the laws of
the State of Minnesota. Signed- Craig
A.
Wensmann Dote: 2
05/25 Reg. No.47466 DATE: 2/
05/25 REV DATE
DESIGN
BY:
DRAWN BY:
ZH CHECKED BY:
CAW/RT DWG FILE:
L3 B3 HS FILE NO.:
22-0259,19 LEGEND: 0
Denotes
found iron monument 0 Denotes
offset iron pipe Denotes set
loth x 976.
4 Denotes existing ground elevation Denotes electrical
cabinet Denotes electric
service T Denotes
telephone pedestal LS 44110
Denotes Peter D. Goers, LS 942. Denotes
proposed elevation f- - Denotes
proposed drainage flow Denotes water
service Denotes sanitary
service Denotes catch
basin Denotes concrete
surface Denotes bituminous
surface Denotes easement
Denotes contour
per grading plan Denotes sanitary
sewer Denotes waterline
SBL - Denotes
building setback line Denotes existing
odjoiners OHE - Denotes