Loading...
2026-00477CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 PAX: (763) 295-4404 ADDRESS 4489 86TH ST NE PIN 155264004110 LEGAL DESC EDMONSON RIDGE LOT 0II BLOCK 004 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION : $ 304,988.84 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: 0 SQ FT FINISHED BASEMENT 0 SQ FT UNFINISHED BASEMENT 969 SQ FT CRAWL SPACE 969 SQ FT FINISHED MAIN FLOOR 1164 SQ FT SECOND FLOOR 60 SQ FT OPEN PORCH 697 SQ FT GARAGE FIREPLACE: NO A/C: YES MECHANICAL: 9 PLUMBING: 17 WATER METER 1 (MAIN) WAC UNITS APPLICANT JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55311- 763) 999-7153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT 1.00 SAC UNITS 1.00 I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date 2 0 2 6- 0 0 4 7 7* DATE ISSUED: 06/23/2026 Permit #: 2026-00477 BUILDING PERMIT FEE PLAN REVIEW STATE SURCHARGE, BLDG VAL SAC FEE 30% SAC FEE 70% WATER ACCESS CHARGE, RESI COMB CONNECTION FEE / RESI SEWER / WATER EXCAVATION PERMIT CONTRACTOR LICENSE VERIFICATION FEE ASSESSMENT SEARCH FEE UTILITY LOCATE FEE, RESI WATER METER 1 (MAIN) MN STATE SALES TAX (MTR 1) TO TA L Payment(s) CHECK 25486 1.00 2,271.08 1,476.20 152.49 1,507.80 3,518.20 2,732.00 130.00 130.00 5.00 60.00 50.00 520.00 40.95 12,593.72 12,593.72 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY OF Monticeflo BUILDING SAFETY 505 WALNUT STREET, SUITE I City Hall (763) 295-2711 fjDcc Eod MAY 1 %3 2026 Building Inspections (763 PERMIT # / 5-3060 Fax ( 763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: { y '( j'w t A v- ZONED LEGAL: Lot 1 I Block Plat tz-jl v-!' Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name.. JP Brooks Builders Phone: 763-285-4790 State License #: 656554 E-Mail: shelly@jpbrooks.com Address: 13700 Reimer Drive City: Maple Grove State: MN Zip: 55311 Eng./Architect Name: Phone: Address: City: State: Zip: Plumber Name: Northwoods Plumbing Phone: 763-717-8757 Address: 30799 73rd Street City: Plerz State: MN Zip: 56364 Mechanical Name: Recher HVAC Phone: 612-802-6525 Address: 1125 Mississippi Drive North City: Champlin State: MN Zip: 55316 Type of Work Type of Construction BuildinI4 Information 0 New R Single Family Use of building j eS ` eA6 e, Addition Duplex of stories ,,14 C%^ Alteration IJ Multi - Family Floor area sq. ft. Repair Commercial v Estimated value ° Move Industrial of construction Other Other Description of work: I,, f I` 51eb C yyz+je YL..,c) ;fc, 'lU'v w14L-) eie%C'W"'C 1 rzPl.c, I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. AMWI'et &-06y- Applicant Signature 2J14 Application Date 4 1513. 7 SEE BACK FOR PLUMBING AND MECHANICAL INFO. APPLJ"-N1: Please show fixtures that are Fire ,Suppression : (if applicable) Plumbing: (if applicable) No. Fixture Type o. Fixture TypeNo.---,-- Sprinkler Heads Water Closet (toilet) Other /Special FS Device 1 Bathtub L( Lavatory (wash basin) Z Z Shower Kitchen Sink Dishwasher Laundry Tub i 1 Clothes Washer Fire Alarm: (if applicable) j Water Heater Q -- Urinal No. Fixture Type Drinking Fountain 1 Floor Drain of Devices l) Slop Sink Other Outside Faucet TOTAL Future Owner Information: Name: Address: City: State: Zip: Phone #: uplicable. Mechanical: (if applicable) No. Fixture Type Furnace 1 Gas Meter Range Hood Gas Range Water Heater 1 Air Conditioning Mech. Fireplace u ` C Bathroom(s) Exhaust Fan Air Exchanger t 1 Dryer O Gas Opening w/o Fixture TOTAL FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No ADDITIONAL INFORMATION: laluation:' _ onstruction Type: ccupancy Group: c— ivision: quare Footage: j t Z F jn 5 of Stories: , ,3 jet, o of Residential Units: — 0 ete- laximum Occupancy: A/A ire Sprinklers: Yes A!I No Iff-Street Parking Covered: iff-Street Parking Uncovered: 3 uilding Official S C7 / PT: / / Monticello 2026 Residential Building Permit Calculator Address: 4489 86th ST NE Monticello, MN 55362 Legal: Lot 11, Block 4 Edmonson Ridge 1 = Yes 0 = No Sullivan New Residence: I House Type: 2 story Slab on Grade 1 = Yes 0 = No 1 = Yes 0 = No Permit Applicant: Contractor: I Plan Review: I Owner: 0 Master Plan: 0 Master Plan Review = 25% o Bu AM Permit Fee) Crawl Space 969 $ 15.27 14,796.63 Unfinished Basement Area 0 $ 16.50 Finished Basement Area 0 $ 44.05 Main/First Floor Area 9 $ 125.00 121,125.00 Second Floor Area 1,164 $ 115.00 133,860.00 Detached Garage 0 $ 60.00 Attached Garage 697 $ 47.33 32,989.01 Garage Conversion to Living Space 0 $ 47.44 Carport/Gazebo 0 $ 30.90 Pole Barn 0 $ 19.03 Shed - greater than 200 SF 0 $ 40.00 Lean -to -Shed 0 $ 13.25 Basement Finish Only 0 $ 16.00 Remodeled Area 0 $ 17.39 Porch (open) 60 $ 36.97 2,218.20 Porch (3-Season) 0 $ 60.00 Porch (3-Season on Existing Deck) 0 $ 55.00 Porch (Screen Porch/Breezeway) 0 $ 58.48 Solarium 0 $ 94.90 Deck 0 $ 20.00 Deck (Screen In & Roof Over Existing) 0 $ 29.80 In -Ground Pool 0 $ 23.18 Above -Ground Pool 0 $ 11.31 Fireplace - Mechanical/Gas 0 $ 4,892.50 Fireplace - Masonry 0 $ 22, 660.00 Elevator/Lift/Other 0 CALCULATED BUILDING VALUATION $ 304,988.84 1 = Yes 0 = No Water Hook-up 1 Sani Sewer Hook-up I FEES: BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,270.26 PLAN CHECK 1,475.67 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 152.49 SUBTOTAL 3,903.42 SEWER FEE [SAC] 5,026.00 WATER FEE ]WAC] 2,732.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 60.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 520.00 SUBTOTAL 8.648.00 TOTAL FEES CALCULATED 12.551.42 Escrow Amount - (Winter OnIN ) TOTAL AMOUNT TO BE PAID TO CITY 121551.42 PAddress: j/S- Builder: .Jr8"16s Two sets Building Plans 643—Z(O Two sets Surveys Survey sent to Engineering for review:s/ZSurvey approved by Engineering: V Energy Calcs vell, HVAC Loads Digital Plans:!!Fjjgj' Correct percentage of Brick & Stone rer L- 1 26 Plan Review letter generated V Received by Building Department: 'Z( Review completed by g p BuildingDepartmentPermit fees calculated 2- 0Z6 Plan Review Checklist Plan Review Letter: J i Applicant contacted: 1, —( , Xa v' I -t , ",-- Date Address House size and finishing details ECC verified HVAC Loss Calcs verified Footings and pads highlighted Point loads Any balloon framed walls and stud spacing? Special stairway framing Details on braced walls Blocking on floor framing Bearing wall blocking and bracing Verify any tempered glass Valuation report completed 6- i7--a4f Ivuss Secs Contact applicant for revisions or questions: What: Who: Date Contacted: Due Date for Revisions: Please provide the necessary information by this date: If not received by that date, the application will be removed from the review process and will be treated as a new permit when the information is provided. The review timeframe will start over at that time. Valuation and size entered on front page of application Note finished or unfinished basement on front of application Second page of application: Verify fixtures match plan: plumbing, mechanical, alarms Compete " Additional Information" section Approved COS survey received from Engineering Plan Reviewer's Initials: CITY OF Monticello BUILDING SAFETY RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite 1 MONTICELLO, MN 55362 Date: 6/23/26 Contractor: City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4489 86th Street NE Monticello, MN 55362 JP Brooks 13700 Reimer Drive Maple Grove, MN 5 5 31 1 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: Two Story, Slab on grade 4 Bedrooms 21133 Sq ft Finished 1 1 Page Bldg Building, Mechanical & Plumbing Bob Ferguson — Chief Building Official 763) 271-3214 Bob.Ferguson(a,MonticelloMN.gov Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908 Wayne.Kalla(a,MonticelloMN.gov Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(d;MonticelloMN.gov 763) 271-3222 Steve Kowalczyk — Inspector / Plan Reviewer 763) 271-3253 Steve.Kowalczyk(&MonticelloMN.gov Amy Biren — Building Permit Technician 763) 295-3060 Building_department(a)MonticelloMN.gov Dennis Shafer — Electrical InspectorreviewElectrical 763) 402-5732 outside 443 Lafayette Road North, St. Paul, MN 55155 Office Hrs: 7-8:30am of city http://www.dli.mn..gov/business/get-licenses-and- ermits/permits CDD and Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-322 ," Angela. Schuniaim(;,MonticelloMN .go,- Bob Ferguson — Zoning Administrator 763) 271-3214 Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer 763)-271-3271 PW Utilities Matt.Leonard(aMonticelloMN.gov Ryan Melhouse — Project Engineer 763) 271-3227 Ryan. Melhouse(a MonticelloMN.gov Mario Frucci — Engineering Technician Mario.FrucciCMonticelloMN.gov 763) 271-3213 Mat Stang - Water & Sewer Superintendent 763) 271-3274 Mat. Stang_(&MonticelloMN. gov The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of Page the Building Plans and Specifications. This review is for Buildinz Construction Permit review only. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION 1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note 2 Bldg n/a general Building Official review and authorization required prior to changes, modifications, note or alterations. 3 bldg n/a general 1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has note been issued. 4 bldg n/a general Final Building, Plumbing, and Heating inspections must be completed prior to note occupancy. The owner or contractor must be present for final building inspection. 5 n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note 6 Bldg n/a general Separate applications and permits Required for Sewer / Water Connection, Heating note A/C Systems, Plumbing, Fire Alarm Systems. bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection 1101.8 d MN Statute Carbon monoxide detectors must be installed in accordance with MN Statute §299F 8 299F .50 50 R315 bldg Buildings must be constructed per current building codes. 2020 MN State Building Code including: n/a general 2020 MN Residential Code 9 note MR 1300 0 2023 National Electrical Code 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. 11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans 12 bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are note installed. 13 bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans for note framing inspection. 14 n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical note work. 15 Maintain 6" Earth to wood separation Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fences are required. Maintain erosion controls until landscaping is completed. Page PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION bldg Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away 17 from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. l Window Fall Protection Required for all windows 6' above grade with sill height of18R312.2 less than 24", maximum opening must be less than 4". 19 bldg WARNING: Call Before You Dig! Gopher State One Call 651-454-0002 bldg. Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not 20 Exceed 3 Air Exchanges Per Hour. 21 l' Flash between House and Stoop. 22 bldg R319.1 Install House Numbers: 4" minimum, visible from street. bldg Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / 23 damper areas are exposed. 24 bldg Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. l'/,l'-' Fire blocking Required: Cut off concealed draft openings between stories and attic. 25 R302.11 Close horizontal to vertical penetrations. bldg Carry Concentrated loads to foundation — Concentrated loads must be solidly26R301.1 blocked and carried continuously to foundation. bldg Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to27daylight; schedule 40 pipe required). 28 bldg R402.4.1.1 Hardboard Backer Required behind tub / shower. 29 bldg Seal and Secure Sump Pump Basket Cover. 30 bldg R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). bldg Fain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install31R405.2.3 flexible hose connection extending to drainage area away from the foundation wall. R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for 32 Subpart 6 future active radon ventilation system. blr/,T Radon gas vent pipes shall be provided with space around the vent pipe for future fan installation. The space required for the future fan installation shall be a minimum of 33 R 1303.2402 24" in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. 34 l'l`l, R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. l khf Install truss clips at each truss and girder end unless otherwise specified by the truss35R802.11 manufacturer. bldg R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to 36 MN Res.Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: 37 R703.2L I Detached Accessory Buildings) 4 1 Page PLAN NO. DEPT SHEET/ CODE SECTION COMMENTS SPEC. SECTION bldg 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2nd course of 38 R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, 1 anchor within 1' of each end. Exterior non -draining foundation insulation requirements: Shall have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal 39 bldg R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: 40 Zoning on Ridge The Establish maximum driveway widths of 24' @ front property line. Zoning OrdinanceZoning Floor joists and blocking shall be connected to the sill plate at the top of the wall 41 R404.1 1-4 with an approved connector with listed capacity meeting top of wall reaction in table R404.1(1). Spacing of blocking shall be in accordance with table R404.1(1). 42 bldg R314.3 If the office is to be used as a sleeping room. A smoke alarm is required in accordance to section R314.3 43 Zoning Edmonson Ridge Front elevation shall have a minimum of 15% Brick or Stone. Zonin Ordinance 5 1 Page New Cori.struCtiOn Energy code Compliance Cerfifioate Per R¢o1.3 Certificate_ A building cerah'cate shall be posted on orin the elecbjcal distribution Data Certificate Paspanel MailingAddr ejss of theDwehing or Dwelling Unit 1/ Gay"`' _ Place your L tl (o t' / r Name Iogo here of Res1deniial contractor JP Brooks MN License Number BC 686554 ERMAL ENVELOPE RADON CONTROL SYSTEI I Type: Check AllThatApply F passive (No Fan) o j-7 Active (With fan and manometer m n 1j _ _ 1( L orothersystem monitoring device) F Location (orfuture lo(--tion) of Fan m _ a m Attic o Q m ID m .C] mRs Insulation Locaton o o a; o m n 2 ozuxocoiv zT o La iT iv u1 L L L C m m a)TJ 'II m Below Entire Slab Rr cv al =Sl L`- L- u Other Please Describe HereNA Foundation Wail R75 PolyBanicr PerimeterofSlab on Grade d t/ Fxterforandiriteiiorasdicfatedbycode Rim Joist (1st Floor) R 0 rnterfor of Foundaffon wag Rim Joist (2nd Floor-f-) R-30 Wall R21 GerTing, slat R-48 CeTng, vaulted S/ R-48 BaylJndows orcantr7evered areas Rio Floors over uncondifioneci area NA Describe other insulated areas Building envelope airtightness: I Uctsystem a;>rfrghfness= NAWindowsDoors Average UFactor (excludesskylightsand one door ; 2LL Heating or Cooling Ducts Outside Condr6oned Spaces Solar Heat Gain CoefEcienf (SHGC): Not applicable, all ducts located in conditioned space INECHANICAL -SYSTEMS yR--value 3 Make-up Air SeJecta Type • Appliances Healing System Domestic Water Heater O°ling System I - I Notrequired permech_ code Fuel Type Nat. Gas Nat. Gas Elect_ El Passive Manufacturer Bryant Richmond B y ant Model 915SB042060E17 l Powered BA013NR030BNG Interlocked with exhaust device_ lnputin Capacity 5 RafingorSizeBTUs 0J0 O in Gallons_- Describe: Output _ Other, describe inTons= 2, _ AFIJF or Etliciency HSPF% g 6j _2 9 Q SEER SEER 13 Location of duct or -system: Heating Loss Heating Gain ResidenffalLoadGalculaiiCOOHng Load y/ S l r$ VICfmI( lIEGHATIIGA 11E%I rI 4TION SYSTEM round duct OR mewl duct Describeanyadditionalorcombinedheatingtwo furnaces gorcoolingsystemsifinstalled: (e-_ ces or air sourceheatpumpwithgasback-up fuma'ce). Combustion Air Selecta Type Select Type Notre qu7redpermech_ code Neat Recover Ventt7ator (xRV) Capacity in dins- Low. Passnre EnergyRecoverVentilafor( ERV) Capacity in cams_ Low_ HJg> i Other, despibe Balanced Ventilation ca a pciiyin rims: High_ 730 Location of ductorsystem: Location offan(s), descrr-be aarhroomsandLaundry Mechanical ROOM Capacitycontinuousveniilation stein dins: Cfm`s Total ventilation Unterrrrittent 4- continuous) rate in cfms: — s "round duct OR metal duct Builders Associaton of Minnesota version 101oJ4 Recher HVAC HVAC Load Calculations for 4489 86th St NE Prepared By: Monday, May 11, 2026 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth,MN 55441 _ _ Pa e 2 Project Report General Proiect Information Project Title: Recher HVAC Project Date: Monday, May 11, 2026 Client Name: 4489 86th St NE Design Data - Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Dry Bulb Winter: -15 Summer: 88 Outdoor Outdoor Indoor Indoor Grains Wet Bulb Be .Hum Bel.Hum Dry Bulb Difference 15 n/a n/a 72 n/a 71 44% 50% 72 30 Check Figures Total Building Supply CFM: 736 CFM Per Square ft.: Square ft. of Room Area: 2,133 Square ft. Per Ton: Volume (ft3): 18,249 FBuildina Loads 0.345 1,247 Total Heating Required Including Ventilation Air: 34,204 Btuh 34.204 MBH Total Sensible Gain: 16,568 Btuh 81 % Total Latent Gain: 3,956 Btuh 19 % Total Cooling Required Including Ventilation Air: 20,524 Btuh 1.71 Tons (Based On Sensible + Latent) Notes ___ Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11.16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 Pa e 3 Miscellaneous Report System 1 House Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data _ Dry Bulb Wet Bulb Rel.Hum Rel.Hum_ Dry Bulb Difference Winter: 15 15 100% n/a 72 n/a Summer: 88 71 44% 50% 72 29.99 Duct Sizing Inputs Main Calculate: Trunk Yes Runouts Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Infiltration Specified: Infiltration Actual: Above Grade Volume Total Building Infiltration: Total Building Ventilation: Winter 0.150 AC/h r 46 CFM 0.150 AC/hr X 18,249 Cu.ft. 2,737 Cu.ft./hr X 0,0167 46 CFM 125 CFM Summer 0.080 AC/hr 24 CFM 0.080 AC/hr X 18-249 Cu.ft. 1,460 X 0,0167 Cu.ft./hr 24 CFM 125 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 17.08 = (1.10 X 0.970 X 16.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.79 = (0.68 X 0.970 X 29.99 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.150 AC/hr (46 CFM), Construction: Tight Summer Infiltration Specified: 0.080 AC/hr (24 CFM), Construction: Tight C-.\ ...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC PI mouth MN 55441 Pa e 4 Load Preview Report Scope Ne ft. To ITo Are Se La Gai Gal Net Gain Sen Loss Hyg CFM Clg CFM Act CFM Duct Siz Building 1.71 1,247 2,133 16,568 3,956 20,524 34,204 396 736 736 Svstem 1 1.71 1,247 2,133 16,568 3,956 20,524 34,204 396 736 736 10x1 Ventilation 854 2,474 3,327 4,643 Zone 1 2,133 15,715 1,482 17,197 29,561 396 736 736 10x 1 1-Main Level 970 6,742 255 6,997 16,544 221 316 316 3-- 2-Upper Level 1,163 8,973 1,227 10,200 13,017 174 420 420 4-- C:\ ...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM is - Residential & Light Commercial HVAC Loads Elite Software Development Steel (Plvmouth) Recher L- outh. MN 55441 P< Duct Size Preview Room or Minim* Maxim* Rough Desig S Duct Duc Htg Clg I Act. Duct Duct Name Veloci Velocit Facto U10 Loss Velocit Lengt FIo1y_ . E1 N_I_.Flow Svstem 1 Supply Runouts Zone 1 1-Main Level Built -In 0 750 0.01 0.1 394 221 316 316 3-- 2-Upper Level Built -In 0 750 0.01 0.1 393.2 174 420 420 4-- Other Ducts in System 1 Supply Main Trunk Built -In 0 900 0.003 0.1 757.2 396 736 736 10x1 Summary Svstem 1 Heating Flow: 396 Cooling Flow: 736 I C:\...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 Pa e 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description -_ - - - - -- - Quan Loss _- Gain _ Gain Gain Vector: Glazing -Vector Window, U-value 0.29, SHGC 194 4,892 0 6,382 6,382 0.31 11 P: Door -Metal - Polyurethane Core, U-value 0.29 57.2 1,442 0 448 448 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 2156.8 12,197 0 2,285 2,285 cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-50: Roof/Ceiling-Under Attic with Insulation on Attic 1162.8 2,023 0 1,186 1,186 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 22D-10pm: Floor -Slab on grade, Vertical board insulation 140 4,178 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 20P-30: Floor -Over open crawl space or garage, Passive, 194.6 593 0 75 75 R-30 _blanket insu_Iationi any_cover, U-_value-0.035 Subtotals for structure: 25,325 0 10,376 10,376 People: 5 1,000 1,150 2,150 Equipment: 0 2,400 2,400 Lighting.- 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 46, Summer CFM: 24 4,236 482 416 898 Ventilation: Winter CFM: 125, Summer CFM: 125 4,643 2,474 854 3,327 Exhaust: Winter CFM: 125, Summer CFM: 125 AED Excursion:- 0 0_--_ 1,373 1.373 Total Building Load Totals: 34,204 3,956 16,568 20,524 Check Figures Total Building Supply CFM: 736 CFM Per Square ft.-. 0.345 Square ft. of Room Area: 2,133 Square ft. Per Ton: 1,247 Volume (ft3): 18,249 Building Loads Total Heating Required Including Ventilation Air: 34,204 Btuh 34.204 MBH Total Sensible Gain: 16,568 Btuh 81 % Total Latent Gain: 3,956 Btuh 19 % Total Cooling Required Including Ventilation Air: 20,524 Btuh 1.71 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) PI mouth MN 55441 Building Pie Chart Floor 14% Roof 6% A/all 'IF%, Wall 11% Glass 31 % Floor 0% Roof 6% Elite Software Development, Inc. Recher HVAC Paa e 7 Ventilation 14% Infiltration 12% Door 4% Glass 14% AED Excursion 7% Ventilation 16% Infiltration 4% Equipment 12% Door 2% People 10% C:\ ...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Elite Software Development, Inc. Recher HVAC Page 8 Detailed Room Loads - Room 1 - Main Level (Average Load Procedures General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 31.3 ft. System Number: 1 Room Width- 31.0 ft. Zone Number: 1 Area: 970.3 sq.ft. Supply Air: 316 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 2.1 AC/hr Volume: 8,830 cu.ft. Req. Vent. Clg- 0 CFM Number of Registers: 3 Actual Winter Vent.: 70 CFM Runout Air: 105 CFM Percent of Supply.: 22 % Runout Duct Size: 7 in. Actual Summer Vent.: 54 CFM Runout Air Velocity: 394 ft./min. Percent of Supply: 17 % Runout Air Velocity: 394 ft./min. Actual Winter Infil.: 24 CFM Actual Loss: 0.079 in.wg./100 ft. Actual Summer Infil.: 13 CFM Item Area U- Htg Sen Clg Lat Sen Description _ _ Quanti --_Value_. HTM Loss HTM Gain_Gain_ E -Wall-12F-Osw 36 X 9.1 264.4 0.065 5.7 1,495 1.1 0 280 S -Wall-12F-Osw 34 X 9.1 309.4 0.065 5.7 1,750 1.1 0 328 W -Wall-12F-Osw 36 X 9.1 241.6 0.065 5.7 1,366 1.1 0 256 N -Wall-12F-Osw 34 X 9.1 309.4 0.065 5.7 1,750 1.1 0 328 E -Door-11 P 2.7 X 6.7 18.1 0.290 25.2 456 7.8 0 142 E -Door-11 P 2.7 X 6.7 18.1 0.290 25.2 456 7.8 0 142 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.8 0 164 E -GIs-Vector shgc-0.31 0%S 6 0.290 25.2 151 33.7 0 202 W -GIs-Vector shgc-0.31 0%S 9 0.290 25.2 227 33.7 0 303 W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 33.6 0 1,412 W -GIs-Vector shgc-0.31 0%S (2) 35 0.290 25.2 884 33.6 0 1,176 Floor-22D--10pm 140 ft..Per. 140 0.343 29.8_- 4,178 0.0 _ 0 0 Subtotals for Structure: 14,303 0 4,733 Infil.: Win.: 24.1, Sum.: 12.9 1,274 1.759 2,241 0.173 255 220 AED Excursion: 589 Equipment: 0 ______1,200 Room Totals: 16,544 255 6,742 C:\...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth, MN 55441 Page 9 Detailed Room Loads - Room 2 - Upper Level (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 34.2 ft. System Number: 1 Room Width: 34.0 ft. Zone Number: 1 Area: 1,162.8 sq.ft. Supply Air.- 420 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 2.7 AC/hr Volume: 9,419 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 55 CFM Runout Air: 105 CFM Percent of Supply.: 13 Runout Duct Size: 7 in. Actual Summer Vent.: 71 CFM Runout Air Velocity: 393 ft./min. Percent of Supply: 17 Runout Air Velocity: 393 ft./min. Actual Winter Infil.: 21 CFM Actual Loss: 0.079 in.wg./100 ft. Actual Summer Infil.: 11 CFM Item Area U- Htg Sen Clg Lat Sen Descri tion Quanta ValueHTM Loss HTM Gain Gain E -Wall-12F-Osw 36 X 8.1 246.6 0.065 5.7 1,395 1.1 0 261 S -Wall-12F-Osw 34 X 8.1 275.4 0.065 5.7 1,557 1.1 0 292 W -Wall-12F-Osw 36 X 8.1 240.6 0.065 5.7 1,361 1.1 0 255 N -Wall-12F-Osw 34 X 8.1 269.4 0.065 5.7 1,523 1.1 0 285 E -GIs-Vector shgc-0.31 0%S (3) 45 0.290 25.2 1,134 33.6 0 1,512 W -GIs-Vector shgc-0.31 0%S (3) 45 0.290 25.2 1,134 33.6 0 1,512 W -GIs-Vector shgc-0.31 0%S 6 0.290 25.2 151 33.7 0 202 N -GIs-Vector shgc-0.31 100%S 6 0.290 25.2 151 10.5 0 63 UP-Ceil-16B-50 34.2 X 34 1162.8 0.020 1.7 2,023 1.0 0 1,186 Floor-20P-30 14 X 13.9 194.6 0.035 3.0 593 0.4 0 75 Subtotals for Structure: 11,022 0 5,643 Infil.: Win.: 21.5, Sum.: 11.5 1,134 1.759 1,995 0.173 227 196 AED Excursion: 784 People: 200 lat/per, 230 sen/per: 5 1,000 17150 Equipment: 0 1,200 Room Totals: 13,017 1,227 8,973 C:\...\Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) PI mouth MN 55441 System 1 Room Load Summary- _- - - Htg Min Run Room Area Sens Htg Duct No Name SF Btuh CFM Size Zone 1--- 1 Main Level 970 16,544 221 2 Upper Level _-.._.__.._.._..__1 163 13,017 174 Ventilation _ -- 4,643 System 1 total 2,_1.33 34,204 396 System 1 Main Trunk Size: 10x14 in. Velocity: 757 ft./min Loss per 100 ft.: 0.103 in.wg Cooling System Summary Elite Software Development, Inc. Recher HVAC Page 10 Run Clg Clg Min Act Duct Sens Lat Cig Sys Vel Btuh Btuh CFM CFM 3-7 394 6,742 255 4-7__ 393 _ 8,973 1_,227_- - 854 2,474 16,_568 3,956 Cooling Sensible/Latent Sensible TonsSplit Btuh__ Net Required.- 1.71 81 % / 19% 16,568 Equipment Data Heating System Type: Natural Gas Furnace Model: Indoor Model: Brand: Efficiency: 0 AFUE Sound: 0 Capacity: 0 Btuh Sensible Capacity: n/a Latent Capacity: n/a 316 316 420 420 736 736 Latent Total Btuh Btuh 3, 956 20,524 Cooling System Standard Air Conditioner 0 SEER 0 0 Btuh 0 Btuh 0 Btuh C:\ ...\ Recher HVAC - 4489 86th St NE.rh9 Monday, May 11, 2026, 11:16 AM INE E SOTA COPYRIGHT NOTICE THIS ARCHITECTURAL PLAN SET AND THE DESIGN ELEMENTS REPRESENTED ON D W voEACHINDIVIDUALPAGEINCLUDINGBUTNOTLIMITEDTO, FLOOR PLAN AND 0 C_ rn ELEVATION DESIGN, DETAILS, INFORMATION, AND CONCEPTS IS PROPRIETARY m o r- AND DEVELOPED FOR THE EXCLUSIVE USE OF JP BROOKS INC. D m USE AND/OR REPRODUCTION OF ANY PORTION OF THIS PLAN SET IN ANY o 10 O rn y r C' C FORM IS STRICTLY PROHIBITED WITHOUT EXPRESSED WRITTEN PERMISSION OF JP m ;;u BROOKS. VIOLATION WILL BE SUBJECT TO ALL APPLICABLE COPYRIGHT LAWS. o- 0 O 7 Z r u,Z<n VfA CTHE BUILDING CODEO AND DESIGN DISCLAIMER o Z rn m o m M O HOME PLAN REPRESENTED IN THIS PLAN SET HAS BEEN DESIGN TO COMPLY Q , WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE IRC AND THE 2 2 INTERNATIONAL C oo ON O ENERGY CONSERVATION CODE (IECC). THE DESIGN OF THIS cn M z HOME PLAN IS DRAWN AS ACCURATELY AS POSSIBLE, HOWEVER, FINAL U, ttnn t, CONSTRUCTION MAY DIFFER SLIGHTLY FROM PLANS DUE TO STRUCTURAL ADJUSTMENTS, FIELD a p CONDITIONS, OR OTHER DESIGN CONSIDERATIONS. Monticello Ru ior+c t rery APPROVED FILE COPY REVIEWED FOR CODE COMPLIANCE SUBJECT TO FIELD INSPECTION Date: Signature: SHEET INDEX E T SNEET TITLE TITLE SHEET 7l'PICAL FRAMING DETAILS WALL BRACINr-;; PLAN EUJP GALCS ELEVATIONS 4 ROOF PLAN FOUNDATION PLAN MAIN FLOOR PLAN UPPER FLOOR PLAN ELECTRICAL PLANS INTERIOR ELEVATIONS/CABINETS BUILDING SECTIONS BUILDING SECTIONS GENERAL NOTES TYPICAL WALL SECTIONS TYPICAL DETAILS TYPICAL DETAILS 0 y m z 0 o 00 r O W co v O n Z 0 E z c DRAWING RECORD REVIEW SET 04.15.2026 PERMIT SET 04.29.2026 FINAL SET 05.19.2026 REVISED SET 06.15.2026 SQUARE FOOTAGE MAIN FLOOR FINISHED UPPER FLOOR FINISHED 969 1 164 TOTAL FINISHED 2133 FOUNDATION 969 OVERALL SQUARE FEET 3102 GARAGE 697 TITLE SHEET 00 4489 86th Street NE r I F Lot 11 Block 4 - Edmonson Ridge Monticeflo NG 5Af t> Builder: JP Brooks Builder 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: V/ Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. Proposed building elevations of lot corners. Proposed elevations at building corners. Proposed elevations on the side yard swales at the extension of building corners and hi h points. Proposed and as -built elevations of garage slab and lowest floor on walkouts. Top of curb elevation at the extension of property lines and center of driveway. Proposed elevations and location of any critical drainage ways located on the site natural or man-made indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Erosion control *Must be installed prior to starting construction and maintained to be compliant with City requirements and project SWPPP. Follow City Standard Detail Plate 6006. Proposed driveway location, width at lot line, % of slope. Show proposed porches, cantilevers, bay windows, and decks (if being constructed). N/A Show individual significant trees 36" DBH (Diameter Breast Height)or larger N/A Existing or proposed retaining wall(s) top and bottom elevations. Show adjacent property topo related to drainage with arrows. Proposed sump pumpoutlet location on buildinq footprint (natural drainage or piped to curb). Show any Drain Tile installed in theyard.---* 'Show sump pump location on final as -built City will accept only originals or quality hard copies of the as -built survey and certification of grading. PROPOSED HOUSE ELEVATIONS REFERENCE BENCHMARK: NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY Top of Foundation Elev = 967.5 Rim of sanitary manhole on 86th St. NE Garage Floor Elev = 967.2 near West plat boundary. THE LOCAL BUILDING INSPECTON Elevation = 957.15 feet (Plat Datum) LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. ELEV PER GRADING PLAN Certificate of SurveyBEARINGANDDISTANCEINFORMATIONISPERTHERECORDEDPLAT. Plans by Alliant. PROPOSED IMPERVIOUS SURFACES Garage Floor Elev = 967.4 Total lot Area = 10,440± S.F. For EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. Lowest Floor Elevation = 960.4 House/Stoop Area = 1,726± S.F. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. Rear Elevation = 964.4 Driveway/Walk Area = 747 S.F. JP Brooks Builders THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. L- Lookout Total Impervious Area = 2,473± S.F. (23.7%) Lot 11, Block 4, EDMONSON RIDGE PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO SOD AREA: DRIVEWAY AREA TO STREET: City of Monticello, Wright County, Minnesota Full Yard = 8,242± S.F. 833± S.F. (Excluding Sidewalk) VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). 30' Behind House = 3,382 ZONING HOUSE TYPE Address: 4489 86th Street NE, Monticello, MN 55362 STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. SETBACKS OFFSETS P.U.D. Slab On Grade N UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 25' Front OS#1 - 966.44 (BM) ( The Sullivan) PROPOSED DING SURVEY 7/29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. SANITARY STUB INVERT=956.6± PER PLAN. 7' Side OS#2 = 965.76 PROJECT BENCHMARK 30' Rear OS43 = 965.25 Top of hub w/tack at most SE'ly Approved Date 6/1 /2026 20' Side Street OS#4 = 966.01 Building corner offset Elevation = 966.44 Feet (Plat Datum ) X X 960'$ i 959.9 X 962.8 X 963.7 j 1 IOr-- ram, ,--, I .-. ,--- I I I I X-) , L-- LI V I .- I V-/ 1 V I i cot)i 2 d PID: 155-264-004060 I I I CO1 PID:155-264-004100 X X I I e IPY" 44110-- 9 Cn 6p Oro OI O r k --964 ------ l X OS 3 ' rn X °' 9 O ° I I i O> 66 S882310E193.88 965.25 ,,co \ OS# 4 9 IP}" 96S 11V Open I '6 X 966.01 E P 0 1-----------_-_-_- X -- I ,------ D-- t 2/0 48.00 o I 25.33 ' \\ I . r\.---- - -- : I- .. - :- - :- :7.`.- :. :-.r I ------- '- 967_0;__`\ I __2a I I - --- 4411 IPy„ 12 I \ I r I 96S 34.00 5 -T... o --- 44110 N 44110 / 1 \ I I X 8% ' 96 o F 251--- R - -- --- 1 \ I I - - I Proposed o - I 12 1 N \ I y-RIM=956.4 j ,,pro Cr 964 j House O - F 5 /CS 1 LA / I - I co I I #4489 co. 9S9 _ I _ _ I X I rO 14.00 N\ I' ll I X 95 11 ro I I ro 10l - 26. 4 X \ m - 30 I- - 1 O 1 I X ICI ICI I PID: 155-264-004110rn 1oOProposed1o. X 9S1 I` 11 % I 1 g6S ME" i I Area: 10,440± S.F. Driveway 6,`g65 o , 61 orO`N, I 1 I I 9+ 1 (0.24±Ac.) 5.7% X1 N \ I 1 I I 11% I ---- 1 CrXI i t I "-- j Proposed 2.0 - 125.3 I Gara e-----L----- D \ s , i - t I I `O 23.501 g o I ASS 12 X y/ % _ I I o h I CD I 1 ,- 96 o ho 20.0 04p 1 I , 1 I O-1-------------- ......._----•-•--•- ... I- S6 t 22.60 6, o J'_--_____I___ 0CO /` I 119. 40 I 9640 9654 X\\ 29 1%> ---- ` 9_-OJ--o 1 fi`=o ----u IPiz" // i I X v 5 -- . a -_ o ,-}O i -22/L - 48.00 21v_ I 1 ?/-`n 25. 33 44110' ' S88°23'10"E 1 .73t S#2 ,--- ,, ° X I j 9' 965. 76 ,966 s <oro/i Project BM IPy" Elev: 966. r--- 968--------- 446, 441101 Ss X pro 1 X I PID: 155-264-004120 r 1 r r-- PID: 155-264-004020 , , 1 Off' I I 1 I i i I- I pK n I r i i L Drainage and Utility Easements are shown thus: f 6 212 L------- j------ N. T.S. Being 6 feet in width and adjoining lot lines and 12 feet in width and adjoining street lines and rear lot lines as shown on this plat, unless otherwise shown. I I °5(1I I I X X t X°' I 1 I I 1 I I t I I 60 n D M ZI 00 9 rn X X 1 o zo ao SCALE IN FEET LEGEND E00: 01 PROPOSED ELEVATION STORM SEWER CATCH BASIN PER PLAN) STORM SEWER INLET STRUCTURE PER PLAN) WCS O CURB STOP (PER PLAN) BITUMINOUS SURFACE (PER PLAN) d d CONCRETE SURFACE (PER PLAN) 1234----- CONTOURS (PER PLAN) EASEMENT LINE ADJOINING LOT LINE BOUNDARY LINE SETBACK LINE STORM SEWER GRAVITY MAIN PER PLAN) I WATER MAIN LINE (PER PLAN) ws WATER SERVICE LINE (PER PLAN) SANITARY GRAVITY MAIN PER PLAN) ss SANITARY SERVICE LINE (PER PLAN)