Loading...
2024-00572CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 4490 86TH ST NE PIN 155264003040 LEGAL DESC EDMONSON RIDGE LOT 004 BLOCK 003 PERMIT TYPE : BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION S 276.205.63 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: SQ FT FINISHED BASEMENT SQ FT UNFINISHED BASEMENT SQ FT FINISHED NIAIN FLOOR SQ FT OPEN PORCH SQ FL GARAGE FIREPLACE: YES/ NO A C' YES / NO MECHANICAL: PLUMBING: WATER ME TER 1 (MAIN) 1.00 SAC UNITS WAC UNITS 1.00 1 9911us". 111 JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55369- 763) 999-7 153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the Citv of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that anv damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date iiiiiiiiiiiiiiiiiiiiiillillillillillillilliililign 2 0 2 4— 0 0 S 7 2 DATE ISSUED: 07/15/2024 Permit #: 2024-00572 1.00 BUILDING PERMIT FEE 2,104.76 PLAN REVIEW 1,368.09 STATE SURCHARGE, BLDG VAL 138.10 SAC FEE 30% 1,407.60 SAC FEE 70% 3,284.40 WATER ACCESS CHARGE, RESI 2,090.00 COMB CONNECTION FEE / RESI 130.00 SEWER/ WATER EXCAVATION PERMIT 130.00 CONTRACTOR LICENSE VERIFICATION FEE 5.00 ASSESSMENT SEARCH FEE 50.00' UTILITY LOCATE FEE, RESI 50.00 WATER METER I (MAIN) 412.00 MN STATE SALES TAX (MTR 1) 30.39 TOTAL 11,200.34 Payment(s) CHECK 20897 11200.34 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. r CITY OF Monticello BUILDING SAFETY J U N ` 2024 PERMIT # u 505 WALNUT STREET, SUITE 1 ON OW 5362 City Hall (763) 295-2711 Rnildin¢ insn .c innc (76145-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: LAL-1 9 V0,", %V'wt til e.. ZONkD LEGAL: Lot Li Block Plat RIJ®jQ. Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders Phone: 763-285-4790 State License #: 656554 E-Mail: shelly@jpbrooks.com Address: 13700 Reimer Drive City: Maple Grove State: MN Zip: 55311 Eng./ Architect Name: Address: Plumber Name: Northwoods Plumbing Address: 30799 73rd Street Mechanical Name: Recher HVAC Address: 1125 Mississippi Drive North Tvve of Work New Addition Alteration Repair Move Other Description of work: City: City: Pierz City: Champlin Tvve of Construction A Single Family Duplex Multi - Family Commercial Industrial Other Phone: State: Zip: Phone: 763-717-8757 State: MN Zip: 56364 Phone: 612-802-6525 State: MN Zip: 55316 Building Information Use of building of stories < i-.VI-1 Sp 1,+ Floor area sq. ft. t415f® c9l Estimated value ' Z% 205, 63 of construction $ - ; I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE BACK FOR PLUMBING 0I L, AND MECHANICAL INFO. Applicant Signature Application Date APPLICANT: Please show fixtures that are applicable. Fire Suppression : (if applicable) Plumbinz: (if applicable) Mechanical. (if applicable) No. Fixture Tvne No. Fixture Tvne No. Fixture Tvne Sprinkler Heads Water Closet (toilet) 1 Furnace Other /Special FS Device Bathtub Gas Meter Lavatory (wash basin) 1,_ Range Hood Shower 1. Gas Range Kitchen Sink 4E— Water Heater Dishwasher A Air Conditioning Laundry Tub Mech. Fireplace I Clothes Washer q_ Bathroom(s) Exhaust Fan Fire Alarm: (if applicable) Water Heater 4= Air Exchanger Urinal Dryer No. Fixture Tvve Drinking Fountain Gas Opening w/o Fixture Floor Drain of Devices Slop Sink Other Outside Faucet tom'- TOTAL 6 2- TOTAL Future Owner Information: Name: Address: FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No City: ADDITIONAL INFORMATION: Valuation: 2-74. 2 0 ,4 State: Zip: Construction Type: V i3 Occupancy Group: T_ Kc. 1 Phone #: Division: 62amuln TO^ IZ: Square Footage: of Stories: %.1,>.T of Residential Units: / - 4 vi e-- Maximum Occupancy: AIA Fire Sprinklers: Yes J' No Off -Street Parking Covered: Off -Street Parking Uncovered: 3 uilding Official BPT: Monticello Address: Legal: New Residence: Permit Applicant: JP Brooks Crawl Space Unfinished Basement Area Finished Basement Area Main/First Floor Area Second Floor Area Detached Garage Attached Garage Garage Conversion to Living Space CarporUGazebo Pole Bam Shed - greater than 200 SF Lean -to -Shed Basement Finish Only Remodeled Area Porch (open) Porch (3 -Season) Porch (3-Season on Existing Deck) Porch (Screen Porch/Breezeway) Solarium Deck Deck (Screen In & Roof Over Existing) In -Ground Pool Above -Ground Pool Fireplace - Mechanical/Gas Fireplace - Masonry Elevator/Lift/Other Water Hook-up Sanitary Sewer Hook-up FEES: 2024 Residential Building Permit Calculator 4490 86th St NE 1 =Yes 0=No House Type: 3 level, NA alk Out 1 = Yes 0 = No I = Yes 0 = No Contractor: I Plan Review: I Owner: 0 Master Plan: 0 Master Plan Revint, = 25% of Building Pennit Fee) 0 15.27 730 16.50 12,045.00 267 44.05 11,761.35 997 125.00 124,625.00 835 115.00 96,025 00 U 60.00 638 47.33 30,196.54 0 47.44 0 30.90 0 19.03 0 40.00 0 13.25 0 16.00 0 17.39 42 36.97 1,552.74 0 60.00 0 55.00 0 58.48 U 94.90 0 20.00 U 29.80 0 23.18 0 11.31 0 4,892.50 0 22.660.00 0 CALCULATED BUILDING VALUATION $ 276,205.63 1 = Yes 0 = No 1 I BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,104.05 PLAN CHECK 1,367.63 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 138.10 SUBTOTAL 3,614.78 SEWER FEE [SAC] 4,692.00 WATER FEE ]WAC] 2,090.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 50.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 442.69 SUBTOTAL 7,584.69 TOTAL FEES CALCULATED $ 11.199.47 Escrow Amount - (Winter Only) TOTAL AMOUNT TO BE PAID TO CITY $ 11,199.471 Recher HVAC HVAC Load Calculations for 4490 86th Street NE r bntkeuo . PPROVED FILE COPY REVIEWEC, FOR Cope Cop'PUANCESUG.E?' 0 FIEIC, INSPELTIONDar,: 518nature. 7 t k Prepared By: Tuesday, June 4, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential $ Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 ov Project Report General Proiect Information Project Title: Recher HVAC Project Date: Tuesday, June 4, 2024 Client Name: 4490 86th Street NE Desion Data Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: St. Cloud AP, Minnesota Front door faces East Medium 45 Degrees 1024 ft. 0.964 Elite Software Development, Inc. Recher HVAC Paae 2 Outdoor Outdoor Outdoor Dry Bulb Wet Bulb Rel.Hum Rel.Hiu]1 Indoor Indoor Grains Bulb Winter: -20 -20 n/a n/a y Difference 72 n/a Summer: 88 71 44% 50% 75 24 Check Figures Total Building Supply CFM: 844 CFM Per Square ft.: 0.489 Square ft. of Room Area: 1,727 Square ft. Per Ton: 949 Volume (ft'): 11,579 Buildina Loads Total Heating Required Including Ventilation Air: 41,953 Btuh 41.953 MBH Total Sensible Gain: 18,544 Btuh 85 % Total Latent Gain: 3,281 Btuh 15 % Total Cooling Required Including Ventilation Air: 21,825 Btuh 1.82 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Miscellaneous Report System 1 House Input Data Winter: Summer: Duct Sizino Inputs Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Outside Air Data Infiltration Specified: Infiltration Actual: Above Grade Volume Total Building Infiltration: Total Building Ventilation: Elite Software Development, Inc. Recher HVAC Paae 3 Outdoor Outdoor Outdoor Indoor Indoor Grains Dr_v Bulb Wet Bulb Rel.Hum Rel.Hum Dr_v Bulb Difference 20 -20 100% n/a 72 n/a 88 71 44% 50% 75 23.88 Main Trunk Yes Yes 0.00300 0.1000 1n.wg./100 ft. 0 ft./min 900 ft./min 0 in. 0 in. Winter 0.380 AC/hr 73 CFM 0.380 AC/hr X 11,579 Cu.ft. X 4,400 0.0167 Cu.ft./hr 73 CFM 120 CFM Runouts Yes Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min 0 in. 0 in. Summer 0.200 AC/hr 39 CFM 0.200 AC/hr X 11,579 Cu.ft. 2,316 X 0.0167 Cu.ft./hr 39 CFM 120 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.78 = (1.10 X 0.964 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.64 = (0.68 X 0.964 X 23.88 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 97.51 = (1.10 X 0.964 X 92.00 Winter Temp. Difference) Winter Infiltration Specified: 0.380 AC/hr (73 CFM), Construction: Average Summer Infiltration Specified: 0.200 AC/hr (39 CFM), Construction: Average auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 4 Load Preview Report Ne ft. Se La Ne Sen Ht CI A Duct Scope To To Are Gain Gai Gai Lossl CFM CFM CFM S¢ Building 1.82 949 1,727 18,544 3,281 21,825 41,953 502 844 844 Svstem 1 1.82 949 1,727 18,544 3,281 21,825 41,953 502 844 844 10x1 Ventilation 661 1,877 2,539 4,681 Zone 1 1,727 17,883 1,404 19,287 37,272 502 844 844 10x1 1-Lower Level 730 5,141 372 5,513 14,677 198 243 243 3- 2-Main Level 997 12,742 1,032 13,774 22.595 305 601 601 6— auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Pane 5 Duct Size Preview Room or Duct Source I Minimu Maximu Rough Desig SPI Duc Duct Htg Clg Act. Duct Name Veloc' Veloci Facto U10 Loss Veloci Leng Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Lower Level Built -In 0 750 0.01 0.1 411.7 198 24 243 3-6 2-Main Level Built -In 0 750 0.01 0.1 374.9 305r 601 601 6-7 Other Ducts in System 1 SupplvMain Trunk Built -In 0 900 0.003 0.1 759.2 502i 84v 844 10x1E Summary Svstem 1 Heatino Flow: 502 Coolino Flow: 844 auerrrles\ FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Total Buildim Summary Loads Component Descriotion Marvin: Glazing -Marvin, U-value 0.34, SHGC 0.32 11 P: Door -Metal - Polyurethane Core, U-value 0.29 15BO-10sf-8: Wall -Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 15BO-10sf-4: Wall -Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 21 B-20: Floor -Basement, Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 22D-1 Opm: Floor -Slab on grade, Vertical board insulation covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 73, Summer CFM: 39 Ventilation: Winter CFM: 120, Summer CFM: 120 Exhaust: Winter CFM: 120, Summer CFM: 120 AED Excursion: Total Building Load Totals: Check Fiaures Total Building Supply CFM: 844 Square ft. of Room Area: 1,727 Volume (ft'): 11,579 Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Elite Software Development, Inc. Recher HVAC Paae 6 Area Sen Lat Sen Total Quan Loss Gain Gain Gain 278 8,695 0 8,333 8,333 42 1,120 0 292 292 1008 4,973 0 87 87 90 474 0 8 8 1822 10,896 0 1,575 1,575 997 1,834 0 957 957 729.8 1,276 0 0 0 27 852 0 0 0 30,120 0 11,252 11,252 4 800 920 1,720 0 2,400 2,400 0 0 0 0 0 0 0 7,152 604 532 1,136 4,681 1,877 661 2,539 0 0_ 2,779__ 2,779 41,953 3,281 18,544 21,825 CFM Per Square ft.: Square ft. Per Ton: 0.489 949 41,953 Btuh 41.953 MBH 18,544 Btuh 85 3,281 Btuh 15 21,825 Btuh 1.82 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55"1 Building Pie Chart Wall 39% Glass 38% Elite Software Development, Inc. S 1 ; Recher HVAC 1 1/ Paae 7 Floor 5% Roof 4% Roof 4% Wall 8% Ventilation 11 % Infiltration 17% Door 3% Glass 21 % AED Excursion 13% Ventilation 12% Infiltration 5% Equipment 11 % People 8% Door 1 % auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 8 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure_) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 27.0 ft. System Number: 1 Room Width: 27.0 ft. Zone Number: 1 Area: 729.8 sq.ft. Supply Air: 243 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.2 AC/hr Volume: 6,568 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 47 CFM Runout Air: 81 CFM Percent of Supply.: 19 % Runout Duct Size: 6 in. Actual Summer Vent.: 34 CFM Runout Air Velocity: 412 ft./min. Percent of Supply: 14 % Runout Air Velocity: 412 ft./min. Actual Winter Infil.: 21 CFM Actual Loss: 0.106 in.wg./100 ft. Actual Summer Infil.: 11 CFM Item Area U- Htg Sen Clg Lat Sen Description Quantitv Value HTM Loss HTM Gain Gain E -Wall-15BO-10sf-8 48 X 9 432 0.050 4.9 2,131 0.1 0 37 S -Wall-15BO-10sf-8 32 X 9 288 0.050 4.9 1,421 0.1 0 25 S -Wall-15BO-10sf4 10 X 5 50 0.054 5.5 275 0.2 0 8 S -Wall-12F-Osw 10 X 4 40 0.065 6.0 239 0.9 0 35 W -Wall-I2F-Osw 48 X 9 370 0.065 6.0 2,213 0.9 0 320 N -Wall-I5BO-10sf-4 10 X 4 40 0.054 5.0 199 0.0 0 0 N -Wall-12F-Osw 10 X 5 35 0.065 6.0 209 0.9 0 30 N -Wall-15BO-10sf-8 32 X 9 288 0.050 4.9 1,421 0.1 0 25 W -GIs-Marvin shgc-0.32 0%S 42 0.340 31.3 1,314 34.3 0 1,439 W -GIs-Marvin shgc-0.32 0%S 20 0.340 31.3 626 34.3 0 685 N -GIs-Marvin shgc-0.32 100%S 15 0.340 31.3 469 10.5 0 157 Floor-21 B-20 27 X 27 729.8 0.019 1.7 1,276 0.0 0 0 Floor-22D-1013m 27 ft..Per. 27 0.343 31.6 852 0.0 0 0 Subtotals for Structure: 12,645 0 2,761 Infil.: Win.: 20.8, Sum.: 11.0 643 3.161 2,032 0.235 172 151 AED Excursion: 799 People: 200 [at/per, 230 sen/per: 1 200 230 Equipment: _ 0 1,200 Room Totals: 14,677 372 5,141 auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 9 Detailed Room Loads - Room 2 - Main Level (Avera_ge Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Item DescriDtion E -Wall-12F-Osw 48 X 9 S -Wall-12F-Osw 42 X 9 W -Wall-12F-Osw 48 X 9 N -Wall-12F-Osw 42 X 9 E-Door-11 P 3 X 7 E-Door-11 P 3 X 7 E -GIs-Marvin shgc-0.32 0%S (2) S -GIs-Marvin shgc-0.32 0%S (2) W -GIs-Marvin shgc-0.32 0%S W -GIs-Marvin shgc-0.32 0%S (2) W -GIs-Marvin shgc-0.32 0%S W -GIs-Marvin shgc-0.32 0%S (2) W -GIs-Marvin shgc-0.32 0%S N -GIs-Marvin shgc-0.32 100%S (2) UP-Ceil-16B-50 32.2 X 31 Subtotals for Structure: Infil.: Win.: 52.5, Sum.: 27.6 AED Excursion: People: 200 lat/per, 230 sen/per: Equipment: Room Totals: Htg. & clg. Occurrences: 1 32.2 ft. System Number: 1 31.0 ft. Zone Number: 1 997.0 sq.ft. Supply Air: 601 CFM 9.0 ft. Supply Air Changes: 4.0 AC/hr 8,973 cu.ft. Req. Vent. Clg: 0 CFM 6 Actual Winter Vent.: 73 CFM 100 CFM Percent of Supply.: 12 % 7 in. Actual Summer Vent.: 86 CFM 375 ft./min. Percent of Supply: 14 % 375 ft./min. Actual Winter Infil.: 53 CFM 0.071 in.wg./100 ft. Actual Summer Infil.: 28 CFM Area U- Htg Sen Cig Lat Sen Quantitv Value HTM Loss HTM Gain Gain 360 0.065 6.0 2,153 0.9 0 311 370 0.065 6.0 2,213 0.9 0 320 299 0.065 6.0 1,788 0.9 0 258 348 0.065 6.0 2,081 0.9 0 301 21 0.290 26.7 560 7.0 0 146 21 0.290 26.7 560 7.0 0 146 30 0.340 31.3 938 34.3 0 1,028 8 0.340 31.3 250 19.3 0 154 42 0.340 31.3 1,314 34.3 0 1,439 25 0.340 31.3 782 34.2 0 856 20 0.340 31.3 626 34.3 0 685 30 0.340 31.3 938 34.3 0 1,028 16 0.340 31.3 500 34.3 0 548 30 0.340 31.3 938 10.5 0 314 997 0.020 1.8 1,834 1.0 0 957 17,475 0 8,491 1,620 3.160 5,120 0.235 432 381 1,980 3 600 690 0______ 1,200 22,595 1,032 12,742 auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM Rhvac - Residential $ Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 10 System 9 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM Zone 1--- 1 Lower Level 730 14,677 198 3-6 412 5,141 372 243 243 2 Main Level 997 22,595 305 6-7 375 1_2_,742 1,032 601 601 Ventilation 4,681 661 1,877 System 1 total _ 1,727 41,953 502 88,5.44 3,281 844_ 844 System 1 Main Trunk Size: 10x16 in. Velocity: 759 ft./min Loss per 100 ft.: 0.096 in.wg Coolina Svstem Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.82 85% / 15% 18,544 3,281 21,825 Ea_uioment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh auerfiles\FILES ...\Recher HVAC 4490 86th Street NE.rh9 Tuesday, June 4, 2024, 10:16 AM New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Posi panel. I Place your Maili giA dress of the Dwelli or Dwelling Unit 9 Ij E City Poo " 1 W 1 D logo here Name of Residential Contractor JP Brooks Builders MN License Number BC 686554 ITHERMAL ENVELOPE RADON CONTROL SYSTEM I Type: Check All That Apply I passive (No Fan) f CRJpr B fig` ` IV(pgti(ICy Active (With fan and monometer y or other system monitoring device) APPROVED FILE COPt° y Location (or future location) of Fan: a RF IIFwED FOR CODE COMPLIANCE m o 0 Attic I SU -iEi:T T=t FIELD INSPECTION 3 n _ EL ccQmmU -2 o c Dale ,% - l2- 2?t Al o 6 m ° a .2 2 z NInlationLocation Signaturo Z tIIm rn rn v O w o E E om I° c at at 10 m Z 1 E ti 2) E it Other Please Describe Here Below Entire Slab I NA I Poly Barrier Foundation Wall I R-15 I I Exterior and Interior as dictated by code Perimeter of Slab on Grade I R-15 Interior of foundation wall If Rim Joist (1st Floor) I R-30 Rim Joist (2nd Floor+) I R-30 I Wall r R-21 Ceiling, flat R-48 Ceiling, vaulted R-48 V1 Bay Windows or cantilevered areas I R-30 Floors over unconditioned area I NA Describe other insulated areas Building envelope air tightness: I Duct system air tightness: I NA Windows & Doors I Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 28 I Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): I28 I lR-value MECHANICAL SYSTEMS I Make-up Air Select a Type Appliances Heating System Domestic Water Cooling SystemHeater Not required per mech. code Fuel Type Nat. Gas Nat. Gas Elect. I passive Manufacturer I Bryant Richmond I Bryant II IPowered 915SB042060E17 I I BAC13NR030BNG II I Interlocked with exhaust device. Model Describe: Input in Capacity BTUS: 60,000 Iin 50 output Z Olin Other, describe: II IRatingorSizeGallons: Tons: AFL1E or HSPF% 96.2 190 SEERPER 13 Location of duct or system: Efficiency Heating Loss Heating Gain Cooling Load n Residential Load Calculat'jI J+ I -1 5Ili Cfm's II" round duct OR MECHANICAL VENTILATION SYSTEM 11 ^ metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two fumaces or air I Combustion Air Select a Type heat pump with gas back-up furnace): n Not required per mech. codeIsourceSelectTypeInPassiveIHigh: CDHeatRecoverVentilator (HRV) Capacity in cfms: I Low: 190 ( Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low:High: Location130 Balanced Ventilation capacity in cfms: I Mechanical of duct or system: Room Location of fan(s), describe: I Bathrooms and Laundry 11 s jCfMCapacitycontinuousventilationrateincfms: 90 -130 11 s round duct OR Total ventilation (intermittent + continuous) rate in cfms: 1270 I metal duct Builders Associaton of Minnesota version 101014 4490 86th St NE MCITY OF Lot 4 Block 3 - Edmonson Ridge onticello 4tBUILDINGSAFETYBuilder: JP Brooks Builders 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: V Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. V Proposed building elevations of lot comers. Proposed elevations at building comers. Proposed elevations on the side yard swales at the extension of building corners and high points. V/ Proposed and as -built elevations of garage slab and lowest floor on walkouts. V Top of curb elevation at the extension of property lines and center of driveway. Proposed elevations and location of any critical drainage ways located on the site 1 ( natural or man-made) indicated with drainage arrows and percentage of slope. V/ Label all adjacent street and railroad right-of-way. Erosion control Mop - 1 pe insial ed prior to staninq ,onstructior ancJ marru p aredlc, bt con-'ianl a rPquirr nerill afro prc')ec.i SVJF'F'F F,Jllow (_A , Strind,=rind Detail Flate 600E Proposed driveway location, width at lot line, % of slope. Show proposed porches, cantilevers, bay windows, and decks (if being constructed). N/ A Show individual significant trees 36" DBH (Diameter Breast Height)or larger N/ A Existing or proposed retaining wall(s) top and bottom elevations. Show adjacent property topo related to drainage with arrows. Proposed sump pump outlet_ location on building 09tprint (natural drainage or piped to curb). Show any Drain Tile installed in the yard. Shi suFIF, [-Lin, cm on final a b ilf City will accept only originals or quality hard copies of the as -built survey and certification of grading. Mo ntpioelio--- - - - APPROVED FILE COPY RE of WED FOR CODE COMPLIANCE SUBJECT TO FIELD INSPECTION Date. + Signature. 5HEET INDEX 5NEE7 TITLE TITLE SHEET T` I=ICAL FR,4MING DETAILS ELEVATIONS 4 ROOF PLAN LOUDER FLOOR PLAN MAIN FLOOR PLAN ELECTRICAL PLANS ELECTRICAL PLANS INTERIOR ELEVATIONS/CABINETS BUILDING SECTIONS 5UILDINCz SECTIONS GENERr4L NOTES Ti'PICAL W,4LL SECTIONS TYf=ICAL DETAILS T,r'PICAL DETAILS R Z 0 NN DRAWING RECORD REVIEW SET 05.31.2024 PERMIT SET 06.12.2024 SQUARE FOOTAGE MAIN FLOOR FINISHED 997 UPPER FLOOR FINISHED 835 LOWER FLOOR FINISHED 730 TOTAL FINISHED 2562 I FOUNDATION (BOTH LEVELS) 1832 1 OVERALL SQUARE FEET 3664 GARAGE 638 TITLE SHEET Ell 44//0 IP \ 1044/!0 IPW. 155-264-003060 I I V I h- Ir ITV// ll\I I 55Existing lP Ys' Iy I House 60 I / I 9652 j P/D. 155-264-o03050 % I v g6 6aI IPYa' g0. `b7 /P Ya' IP Ya' I — 96?!l 25. ' 23'/ 0" E l?100 6 ! i 9/6 5 i 9s uo 44.0 20 58'00 — = 6t o `4L67 y-,° i5B' 4PPOroposed 6 r n '/ 9 S. J y / 2 y° [ 00 9r- - J _ ,y -S CC`rr1l 71 I _ I _ oo I`' q V I J— E rO` V F"'965 5:1 - 39' 66 17.00 4 P tlw 3 m J 9e• rrvervy I`I MD: 155-264-003040 g64.2 6 62 g pS o L oi Area: 7.750% IF. q > II` 160 _ e — NLJPropo ( O.I8Y- Ac.) Ro, K I 6` 964 R 3I n` 20.0 ,, m o+ ^ ^^ - W c- fi. r: _ 56.00 9659 12 Z` S33row ss = - — — ys -off- — g 63x W y, a+4X5$00 s 4/.67, to :a 964.1 g6 6 °a\ S 9-23'10w E /25 C Drainage and Utility Easements -re Jto g a OS/ 2 /44/ 0 O shownthin1P y2 der. 966.6 "6.05 B I 44110 I tO Os r p 9664 g664 Xg666 T \ L— JL—L-- I g65 g652 P! D. 155-264-003030 X % j64.I N. T.S. I I 1 Being 6 feet In width and adjoining lot V lines and 12 feet in width and adjoining (r L I`L I streetlinesandrearlotlinesasshown - 55 on this plot, unless otherwise shown. SEMACKS HOUSE TYPE 25' Front 4'0' FaundatAm Walkout 7' Slde 30' Rear j((z 20' Side Street P,uD. QNVEWAY AREA TD STREET: 93ly- SF. Full Yard - 5,08x IF. JO' iWind House - 4Jl5V- SF. Total lot Area - 7,7509 SF House Area - z520% IF, bcstr/ N'alk A.ea - ni sF Total Impervious Area - 3,291% IF. (42.5%) ELEV PER GR"NG PLAN Plans by ABhmt. Garage Floor Bev - 969.0 Lowest Floor Elevation - 9620 Roar Elevation - 966.0 L - Lookout R£ FFREMt BENCHMARK.• Rim of sa/Hory manhole an 86th St. NE near West plot boundary. Devotion - 95ZIS feet (Plot Datum) Top of House Foundation E/ev = 969.9 Top of garage Foundation = 969.4 Garage Floor Eiev = 969.1 Lowest Floor Eiev = 966.2 Certificate of Survey for JP Brooks Builders Lot 4 Block 3, EDMONSON RIDGE City of Monticello, Wright County, Minnesota Adtt m 4"W MM 8&9W NF, MondlG^ MN 6fM NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST FLOOR ELEVATION IS SUBJECT To SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE PRIOR To ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/29/2021. PAGES 22-24, BY ALLIANT ENGINEERING. OS// - 966.60 (BM) p t'h "PwwD r-r OS/2 - 966.05 OSj3 - 966.21 osya = 9ea95 6/27/2024 PRO., ECT BENCHMARK - Top of hub w/tack at SW'ly buBdIng caner offset Elevation - 866.60 feet (Plot Datum) X 0 30' 1 SCALE: I" = 30' LEGEND: 0 Denotes found Iron movement Denotes set hub Denotes set lath x 976.4 Denotes existing ground devotion 9423] Denotes proposed elevation Denotes proposed drainage flowDenotes TDenotestelephonepedestalDenotes sable television box Denotes electric service Denotes water se I REV SHEETN0. I hereby certify that this survey, plan, o SBL Denotes sanitary service Denotes sanitary manhole telephone pedestal rIDv Denotes bituminous surface Denotes easement Denotes contour per grading plop Denotes sanitary sewer Denotes waterline Denotes building setback line Denotes existing adjollera DESCRIPTION