2025-00746CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 4526 86TH ST NE PIN 155264003080 LEGAL DESC EDMONSON RIDGE LOT 008 BLOCK 003 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE NEW CONSTRUCTION VALUATION : $ 245,427.33 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: 0 SQ FT FINISHED BASEMENT SOG 0 SQ FT UNFINISHED BASEMENT SOG 1740 SQ FT FINISHED MAIN FLOOR 50 SQ FT OPEN PORCH 551 SQ FT GARAGE FIREPLACE: NO A/C: YES MECHANICAL: 15 PLUMBING: 8 WATER METER 1 (MAIN) 1.00 WAC UNITS 1.00 APPLICANT JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55311- 763) 999-7153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and, igns will be repaired at my expense. Applica r/4Date If / Bldg Official Date SAC UNITS Z 0 Z 5— 0 0 7 4 6 DATE ISSUED: 06/ 10/2025 Permit #: 2025-00746 BUILDING PERMIT FEE PLAN REVIEW STATE SURCHARGE, BLDG VAL SAC FEE 30% SAC FEE 70% WATER ACCESS CHARGE, RESI COMB CONNECTION FEE / RESI SEWER / WATER EXCAVATION PERMIT CONTRACTOR LICENSE VERIFICATION FEE ASSESSMENT SEARCH FEE UTILITY LOCATE FEE, RESI WATER METER 1 (MAIN) MN STATE SALES TAX (MTR1) TOTAL Payment(s) CHECK 23270 1.00 1,920.62 1,248.40 122.71 1,449.90 3,383.10 2,153.00 130.00 130.00 5.00 60.00 50.00 475.00 37.41 11,165.14 11,165.14 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CQcu bD v , i Ln cc MO l \` pp .D L Z3 75hntoC -O 4 ( C >- W vcuO > v m n Cc In O Q _0 C GJ -= O N ++ Q co m v i' co U O a •> v a) v >- >- >- J > += u v v00 > Q '= c u > Q- L v dA o v v v CL H H cn Vn w = a CC cC a Q in v L 0 Q 1 N l LM 0 LIE a' \Vj CITY OF Montice O 4BUILDINGSAFETY - PERMIT _ 505 WALNUT STREET, SUITE 1 , MN 55362 City Hall (763) 295-2711 Building Inspections (763) 295-3060 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS:45)(oVper H F . ZONED LEGAL: Lot I Block 3 Plat F'j r ()0 5 dV\ A-idCjg__ Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders State License #: 656554 Address: 13700 Reimer Drive Eng./Architect Name: Address: Plumber Name: Northwoods Plumbing Address: 30799 73rd Street Mechanical Name: Recher HVAC Address: 1125 Mississippi Drive North Tvve of Work New Addition Alteration Repair Move Other Phone: 763-285-4790 E-Mail: shelly@jpbrooks.com City: Maple Grove State: MN City: City: Pierz City: Champlin Type of Construction 1W Single Family Duplex Multi -Family Commercial Industrial Other Phone: State: Phone: 763-717-8757 State: MN Phone: 612-802-6525 State: MN Zip: 55311 Zip: Zip: 56364 Zip: 55316 BuildinLy Information Use of building ` 1'QS G.Q,I CSL / 6%1` of stories RC." h lr Floor area sq. ft. 1 el ke Estimated value Z it ZY , 3 3 of construction $ , Description of i tp I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. t SE ACK FOR PLUMBING_ 1l 31 D- S AND L INFO. Applicant Sign ure Application Date r f APPLICANT. Please show. fixtures that are applicable. Fire Suppression : (if applicable) Plumbinz. (if applicable) Mechanical: (if applicable) No. Fixture Tvpe No. Fixture Tvpe No. Fixture Tvpe Sprinkler Heads n1 L Water Closet (toilet) Furnace Other /Special FS Device Bathtub Gas Meter Lavatory (wash basin) Range Hood L Shower l Gas Range C Kitchen Sink Water Heater I / Dishwasher Air Conditioning Laundry Tub O Mech. Fireplace Clothes Washer o" _ Bathroom(s) Exhaust Fan Fire Alarm: (if applicable) Water Heater I Air Exchanger Urinal 1 l Dryer No. Fixture Tvpe Drinking Fountain Gas Opening w/o Fixture l Floor Drainl(. of %evices Slop Sink Other 2 Outside Faucet C Dow 1 TOTAL 8 TOTAL Future Owner Information: Name: Address: FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No City: ADDITIONAL INFORMATION: Valuation: State: Zip: Construction Type: Occupancy Group: — Phone #: Division: vm~ol Square Footage: /-1 y0 Y -r` ;,, ; 3 t, e.i / •~e ms of Stories: P Ao n b l er of Residential Units: / One - Maximum Occupancy: /j/ej;r Fire Sprinklers: Yes 8 No Off -Street Parking Covered: V"- Z. Off -Street Parking Uncovered: Z- Building Official BPT: / / CITY OF Monticello Address: Legal: New Residence: Permit Applicant: 2025 Residential Building Permit Calculator 4526 86th Street NE Monticello MN, 55362 Lot 8 Block 3 Edmonson Ridge Monticello, MN 1 = Yes 0 = No I House Type: 1 = Yes 0 = No Contractor: 1 Plan Review: Owner: 0 Master Plan: Master Plan Review = 25% Slab on Grade 1 = Yes 0 = No 1 0 tin.e Permit Fee) Crawl Space 0 15.27 Unfinished Basement Area 0 16.50 Finished Basement Area 0 44.05 Main/First Floor Area 1.740 125.00 217,500.00 Second Floor Area 0 115.00 Detached Garage 0 60.00 Attached Garage 551 47.33 26,078.83 Garage Conversion to Living Space 0 47.44 Carport/Gazebo 0 30.90 Pole Barn 0 19.03 Shed - greater than 200 SF 0 40.00 Lean -to -Shed 0 13.25 Basement Finish Only 0 16.00 Remodeled Area 0 17.39 Porch (open) 50 36.97 1,848.50 Porch (3-Season) 0 60.00 Porch (3-Season on Existing Deck) 0 55.00 Porch (Screen Porch/Breezeway) 0 58.48 Solarium 0 94.90 Deck 0 20.00 Deck (Screen In & Roof Over Existing) 0 29.80 In -Ground Pool 0 23.18 Above -Ground Pool 0 11.31 Fireplace - Mechanical/Gas 0 4,892.50 Fireplace - Masonry 0 22,660.00 Elevator/Lift/Other 0 CALCULATED BUILDING VALUATION $ 245,427.33 1 =Yes O=No Water Hook-up 1 Sanitary Sewer Hook-up I FEES: Escrow Amount - (Winter BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 1,920.03 PLAN CHECK 1,248.02 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 122.71 SUBTOTAL 3,295.76 SEWER FEE [SAC] 4,833.00 WATER FEE ]WAC] 2,153.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 60.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 510.03 SUBTOTAL $ 71866.03 TOTAL FEES CALCULATED $ 11.161.79 On1y) TOTAL AMOUNT TO BE PAID TO CITY 11,161.79 CITY OF Aonticello BUILDING SAFETY RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite 1 MONTICELLO, MN 55362 Date: 5/12/2025 Contractor: City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4526 8 6th Street NE JP Brooks 13700 Reimer Drive Maple Grove, MN 55311 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: Single Story SOG 1,740 Sq ft Finished Electric fireplace, luxury suite and four season porch 1 1 Page Bldg Building, Mechanical &Plumbing Bob Ferguson — Chief Building Official 763) 271-3214 Bob. Ferguson(a;MonticelloMN.go` Wayne Kalla — Inspector/ Plan Reviewer 763) 314 -0908 Wayne.Kalla k,MonticelloMN.go< Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(a MonticelloNIN.go\ 763) 271-3222 Steve Kowalczyk — Inspector / Plan Reviewer 763) 271-3225 Steve.Kowalczyk@MonticelloMN.gov Amy Biren — Building Permit Technician 763) 295-3060 11oMN. ov review Electrical Bill Husom — Electrical Inspector 612)490-0488 outside of city Permits I Minnesota Department of Labor and Industry Office Hrs: 7-8:30am mn. ov 910 — 181h St SE, Buffalo, MN 55313 CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director 763) 271-3224 Ancela.ScliumannL.MonticelloMN.goN, Bob Ferguson — Zoning Administrator 763) 271-3214 N.cov Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer 763)-271-3271 PW Utilities Matt.LeonardO, MonticelloMN.i!ov Ryan Melhouse — Project Engineer 763) 271-3227 Rvan.Melhouse(a;MonticelloMN.P-Ov Mario Frucci — Engineering Technician Mario. Frucci(a;MonticelloMN.aov 763) 271-3213 Mat Stang - Water & Sewer Superintendent 763) 271-3274 Mat. Stanv_(a;MonticelloMN.v-ov The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of 2 1 Page the Building Plans and Specifications. This review is for Building Construction Permit review only. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ SPEC. CODE SECTION COMMENTS SECTION 1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note bldg 2 n/a general Building Official review and authorization required prior to changes, modifications, note or alterations. 3 bldg n/a general 1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has note been issued. bldg 4 n/a general Final Building, Plumbing, and Heating inspections must be completed prior to note occupancy. Owner or contractor must be present for final building inspection. 5 bldg n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note bldg 6 n/a general Separate applications and permits Required for Sewer / Water Connection, Heating note A/C Systems, Plumbing, Fire Alarm Systems. bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection N1101.8) Bldg MN Statute Carbon monoxide detectors must be installed in accordance with M N Statute §299F 8 299F .50 50 R315 bldg Buildings must be constructed per current building codes. 2020 MN State Building Code including: n/a general 2020 MN Residential Code 9 note MR 1300 2023 National Electrical Code 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. 11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans 12 bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are note installed. 13 bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans note for framing inspection. 14 bldg n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical note work. 15 bldg Maintain 6" Earth to wood separation Eng Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fence are required. Maintain erosion controls until landscaping is completed. 3 1 Page PLAN NO. DEPT SHEET/ SPEC. SECTION bldg 17 18 bldg 19 bldg 20 bldg. 21 bldg 22 bldg 23 Bldg 24 bldg 25 bldg 26 bldg 27 Bldg 28 bldg 29 bldg 30 bldg 31 bldg 32 bldg bldg 33 34 bldg 35 bldg bldg 36 37 Bldg CODE COMMENTS SECTION Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. R312 2 Window Fall Protection Required for all windows 6' above grade with sill height of less than 24", maximum opening must be less than 4". WARNING: Call Before You Dig! Gopher State one 65 l -454-0002 Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not Exceed 3 Air Exchanges Per Hour. Flash between House and Stoop. R319.1 Install House Numbers: 4" minimum, visible from street. Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / damper areas are exposed. Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic. Close horizontal to vertical penetrations. R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly blocked and carried continuously to foundation. Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to daylight; schedule 40 pipe required). R402.4.1.1 Hardboard Backer Required behind tub / shower. Seal and Secure Sump Pump Basket Cover. R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). R405.2.3 Fain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install flexible hose connection extending to drainage area away from the foundation wall. R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for Subpart 6 future active radon ventilation system. Radon gas vent pipes shall be provided with space around the vent pipe for future fan R 1303.2402 installation. The space required for the future fan installation shall be a minimum of 24 in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss manufacture. R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to MN Res -Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: Detached Accessory Buildings) 4 1 Page PLAN NO. DEPT SHEET/ SPEC. SECTION bldg 38 39 bldg 40 zoning CODE COMMENTS SECTION 2" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2nd course of R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, l anchor within 1' of each end. Exterior non -draining foundation insulation requirements: have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to a width Not to Exceed 28 Ft. and the Public Street. 5 1 Pa g e New Corisfruction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution Date Certificate Post panel. Mailin Address of the Dwelli g or Dwelling Unit 15Q(0 K)& Name of Residential Contractor JP Brooks THERMAL ENVELOPE 0 n) a) m 0 ro a Insulation Location ct m Below Entire Slab INA Foundation Wall I R 15 Perimeter of Slab on Grade I R-15 Rim Joist (1st Floor) I R20 Rim Joist (2nd Floor*) R-30 Wail R 2i Ceiling, flat R-48 Ceiling, vaulted R-40 Bay Windows or cant levered areas R-5o • Floors over unconditioned area I NA Describe other insulated areas City HovOr W i D MN License Number BC 686554 PIace your logo here RADON CONTROL SYSTEi1J} Type: Check All ThatApply L "] jPassive (No Pan) Active (With fan and monometer Lilorothersystem monitoring device) Location (or future location) of Fan: v m do Attic C) A m o 5 CD L rs" ti x R R Other Please Describe Here Poly Bander Fxterlorand tntedoras dictated bycode intedorof Foundatlon Wag Building envelope airtightness: `Duct system airtightness: I NA Windows & Doors {Heating or cooling Ducts Outside Condiiloned Spaces Average U-Factor (excludes Skylights and one door) l!: X 30 (^ ] Not applicable, all duots located in conditioned space Solar Heat Gain Coefficient (SHGC): 19A 3 1 5j1R value q_5 MECHANICAL SYSTEMS Make-up Air Select Type I Appliances Heating System Domestic Water Heater Cooling System Not required per mech_ code I; , Fuel T e Nab. has Nat. Gas Meet. Passive Manufacturer Bryant Richmond Btyant EI-Powered Model 15SB042060E'1BA013NR030BNG I Interlocked with exhaust device. Describe: input Rating or size in Capacity BTUs 60, 000 (in Gallons: 5O 10"puInTons2c. t 1 Other, describe: AFUE or 96'2 190HsPF% SEER I Location of duct orsystem: Efficiency 1EER 13 Heating Loss Heating Gain Cooling Load Residential Load Calculati c, t "1 ti..l 1 ma's round duct OR f MECHANICAL- VENTILATION SYSTi-M metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two fimaces or air Combustion Air Select Type source heat pump with gas back-up furnace): 1Not requked per mech. code Select 7-ypePassive Heat Recover Ventilator (HRV) Capacity in cfms: Low. 1Hlgh: 1 Other, describe: Energy Recover Ventilator (ERV) Capacity In cfms: Low. ISO 11-119h: IUO Location of duct or system: Balanced Ventilation capacity in cfms: Mechanical Room t_ ocaUon offan(s), describe: Bathrooms and Laundry Cfrig Capacity continuous ventilation rate in cfms: s0.13o i s round duct OR Total ventilation (inter m-ittent •r- continuous) rate in cfms: [270 j " metal duct Builders Associaton of Minnesota version 101014 Recher HVAC HVAC Load Calculations for 4526 86th St Prepared By: Wednesday, April 23, 2025 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth. MN _55441 Project Report General Proiect Information Project Title: Recher HVAC Project Date: Wednesday, April 23, 2025 Client Name: 4526 86th St Design Data Elite Software Development, lnc. Recher HVAC Page 2 Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Winter: -15 -15 n/a n/a 72 n/a Summer: 88 71 44% 50% 75 24 Check Fi ugres - -- - --- Total Building Supply CFM: 592 CFM Per Square ft.: 0.297 Square ft. of Room Area: 1,996 Square ft. Per Ton: 1,434 Volume (ft'): 17,964 Building Loads - Total Heating Required Including Ventilation Air- 37,967 Btuh 37.967 MBH Total Sensible Gain: 14,025 Btuh 84 % Total Latent Gain: 2,676 Btuh 16 % Total Cooling Required Including Ventilation Air: 16,701 Btuh 1.39 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth. MN 55441 Miscellaneous Report System 1 House Input Data Winter: Summer: 1 Duct Sizinq Inputs Elite Software Development, Inc. Recher HVAC Page 3 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference 15 15 100% n/a 72 n/a 88 71 44% 50% 75 23.51 Calculate: Main Trunk Yes Use Schedule: Yes Roughness Factor: 0.00300 Pressure Drop: 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min Maximum Velocity: 900 ft./min Minimum Height: 0 in. Maximum Height: 0 in. Outside Air Data Winter Infiltration Specified: 0.140 AC/hr 42 CFM Infiltration Actual: 0.140 AC/hr Above Grade Volume: X 17.964 Cu.ft. 2,515 Cu.ft./hr 0167 Runouts Yes Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min 0 in. 0 in. Summer 0.070 AC/h r 21 CFM 0.070 AC/hr X 17,964 Cu.ft. 1,257 X 0.0167 Cu.ft./hr Total Building Infiltration: 42 CFM 21 CFM Total Building Ventilation: 100 CFM 100 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.140 AC/hr (42 CFM), Construction: Tight Summer Infiltration Specified: 0.070 AC/hr (21 CFM), Construction: Tight C:\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 _ _ _ Page 4 Load Preview Report i Scope Tonon ft. Tor Are SeraGain Lat Gain Net Gam Sen, Loss H gl CFM, ( ClgSys CFM, Ay CFM Duct Size Building 1.39 1,434 1,996 14,025 2,676 16,701 37,967 384 592 592 Svstem 1 1.39 1,434 1,996 14,025 2,676 16,701 37,967 384 592 592 9x1: Ventilation 1,387 1,551 2,939 9,285 Zone 1 1,996 12,637 1,125 13,762 28,682 384 592 592 9x1; 1-Main Level 1,996 12,637 1,125 13,762 28,682 384 592 592 6-7 CA ... \-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 5 Duct Size Pre vie w Room or Source Minimu Maximo Rough Design SP Du Du Htg Clg l Act. Duct Duct Name Veloc' Veloc _ Fact _ — _ U10t Loss Dud Lengtt W F14 ! FLo1Nt_I _ .5ize- Svstem 1 Supply Runouts Zone 1 1-Main Level Built -In i Other Ducts in System 1 Supply Main Trunk Built -In I Svstem 1 Heating Flow: 384 Cooling Flow: 592 750 0.01 0.1 900 0.003 0.1 Summary 369.2 384 ® 592 6-7 728.7 384 592 9x1 C:\ ...\—UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plymouth. MN 55441 -__- Paae 6 Total Building Summary Loads Component Area Sen Lat Sen Total escri tpion ------------- --- Quan ----- Loss Gain --- Gain_- Gin Vector: Glazing -Vector Winows , U-value 0.29, SHGC 222 5,603 0 5,554 5,554 0.31 11 P: Door -Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud 1536 8,686 0 1,328 1,328 cavity, no board insulation, siding finish, wood studs, U-value 0.065 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 1996 3,473 0 1,916 1,916 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 22D-10pm: Floor -Stab on.grade, Vertical board insulation 200 5,968 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil, U-value 0.343 Subtotals for structure: 24,790 0 9,090 9,090 People: 4 800 920 1,720 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 42, Summer CFM: 21 3,892 325 291 616 Ventilation: Winter CFM: 100, Summer CFM: 100 9,285 1,551 1,387 2,939 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: - - 0_ 0 1,136 1,136 Total Building Load Totals: 37,967 2,676 14,025 16,701 Check Figures - -_ - - ---- --- - --- Total Building Supply CFM: 592 CFM Per Square ft.: 0.297 Square ft. of Room Area: 1,996 Square ft. Per Ton: 1,434 Volume (ft3): 17,964 Building Loads -- --- Total Heating Required Including Ventilation Air: 37,967 Btuh 37.967 MBH Total Sensible Gain: 14,025 Btuh 84 Total Latent Gain: 2,676 Btuh 16 Total Cooling Required Including Ventilation Air: 16,701 Btuh 1.39 Tons (Based On Sensible + Latent) Notes -- -- --- - Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth. MN 55441 Buildinq Pie Chart Floor 16% Roof 9% Wall 23% Roof 11 % Wall 8% Glass 33% Elite Software Development, Inc. Recher HVAC Page 7 Ventilation 24% Infiltration 10% Door 3% Glass 15% AED Excursion 7% Ventilation 18% Infiltration 4% Equipment 7% People 10% Door 2% C:\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Elite Software Development, Inc. Recher HVAC Plvmouth. MN 55441 - Page8l Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length- 49.9 ft. System Number: 1 Room Width: 40.0 ft. Zone Number: 1 Area: 1,996.0 sq.ft. Supply Air: 592 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 17,964 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers.- 6 Actual Winter Vent.: 100 CFM Runout Air: 99 CFM Percent of Supply.: 17 % Runout Duct Size: 7 in. Actual Summer Vent.: 100 CFM Runout Air Velocity: 369 ft./min. Percent of Supply: 17 % Runout Air Velocity: 369 ft./min. Actual Winter Infil.: 42 CFM Actual Loss: 0.069 in.wg./100 ft. Actual Summer Infil.: 21 CFM Item Area U- Htg Sen Clg Lat Sen Description _ Quantity Value HTM Loss _ HTM Gain Gain' E -Wall-12F-Osw 40 X 9 298 0.065 5.7 1,685 0.9 0 258 S -Wall-12F-Osw 60 X 9 496 0.065 5.7 2,805 0.9 0 429 W -Wall-12F-Osw 40 X 9 248 0.065 5.7 1,402 0.9 0 214 N -Wall-12F-Osw 60 X 9 494 0.065 5.7 2,794 0.9 0 427 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 32.8 0 655 S -GIs-Vector shgc-0.31 0%S 20 0.290 25.2 505 17.9 0 358 S -GIs-Vector shgc-0.31 0%S (2) 24 0.290 25.2 606 17.9 0 430 W -GIs-Vector shgc-0.31 0%S 42 0.290 25.2 1,060 32.7 0 1,375 W -GIs-Vector shgc-0.31 0%S 40 0.290 25.2 1,009 32.8 0 1,310 W -GIs-Vector shgc-0.31 0%S 30 0.290 25.2 757 32.7 0 982 N -GIs-Vector shgc-0.31 100%S 42 0.290 25.2 1,060 9.6 0 405 N -GIs-Vector shgc-0.31 100%S 4 0.290 25.2 101 9.8 0 39 UP-Ceil-16B-50 49.9 X 40 1996 0.020 1.7 3,473 1.0 0 1,916 0.343 29.8...._. 5,968___ 0.0 0 0 Subtotals for Structure: 24,790 0 9,090 Infil.: Win.: 41.9, Sum.: 21.0 1,800 2.162 3,892 0.162 325 291 AED Excursion: 1,136 People: 200 lat/per, 230 sen/per: 4 800 920 Equipment: 0 1,200 Room Totals: 28,682 1,125 12,637 C-.\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Svstem I Room Load Summary Htg---- Min --- Run Run Clg Room Area Sens Htg Duct Duct Sens L Name -- --- SF Btuh CFM Size Vel Btuh Zone 1--- 1 Main Level 1,996 28.682 384 6-7 369 12,637 Ventilation 9,285 1,387 Svstem 1 total 1,996 37,967 384 14,025 System 1 Main Trunk Size: 9x13 in. Velocity: 729 ft./min Loss per 100 ft.: 0.107 in.wg Cooling System Summary[_ Cooling Sensible/Latent Sensible Tons Split _ Btuh Net Required: 1.39 84% / 16% 14,025 E ui ment Data Elite Software Development, Inc. Recher HVAC Page 9 Clg Min Act Lat Clg Sys Btuh-- CFM___-CFM 1,125 592 592 1.551 2,676 592 592 Latent Btuh _- 2,676 Type: Heating System Natural Gas Furnace Cooling System Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh Total Btuh 16,701 C:\ ...\-UNTTLO.rh9 Wednesday, April 23, 2025, 8:34 AM J 1VV 0119311NO 00 'o o'QNO3NOVVC13 + CD O 019-s)lo C) 0 uj o o w IaI3 O w 2 wW w90S = z wz LU VOH lVvo afQQ 0 w U-j- D z W 0I_— W w CL,- of Q _, w Z Q ~ NOIS Q Q waf 0ooo z u LLI z z LL - j-a Z z z O LLI ui w zLL 0 a WLL U1U [ LL lu Utu ut +- z . SNOUV8301SNO3 NOIS30 N1 H10 80 "SNOI11aNOO QI313 "S1N3W1Sflfab' QoIb'anionais Ol 3nci SNdld VNOaJ lI1HOlIS a3J31a ),VVN Nouond1SNOO - O Ib'N13 "13n3 MOH 3I vios] 91SSOd St/ JAI 31b'21f1OOb' Sb' NMb'Ia SI Nt/Id 3WOHLa - SIH130 N01S3a 3HI ' (0031) 3000 N011VAa3SNO3 kD83N3 IVNOIIVN 131N1 oo oW Q OZOZ 3H1 aNd (OaI) 3003 IVI1NKIS3a IVNOIIVNN31NI 810Z 3Hl HIMGo cOU X]dWOO01NOISaN339SVH13SNVIdSIH1NIa3N3WOH3H1wi 'oo 83WIVIDSld NJIS3a (MV3a0 ONlaiinaW w Z W >zL9NO w J uuj OQ w 'o c'SMVI 1H0la),dO3 3I9V011ddb' ] IV 011oimS 39 IIIM NOUVIOIn 'S 100219 J CO w LU df JO NOISSIW213d N31llaM a3SS3acJX3 iAOH1IM a31191HO&J AI1O1alS SI WdO h Q 0 ANV NI 13S NVId SIH1 JO N011aOd ANV 30 Noii:Dna02id3N d0/aNV 3sn IN, w ' m 0 0 ' ONI S OOM df 30 3sn 3n snioX3 3H1 aOJ a3dOl3n3a aNV O J A8VI318dOad SIS1d3ONOOaNV 'NOliVVgd03N1 "SIld13a "NOIS3a NOIIVA313 m Q aNV NVId cIOOIJ 'Ol a311WII ION lfl9 JNIaniDNI 3 Vd ivnClnlaNl HOd3 NO a31N3Md3a S1NIW313 NOIS3a 3H1 (INV ES NVId IVan13311HOaV SIH1 LU 30IION 1H lSAdO:) -T- n6 l r V 4526 86th St Ne CITY OF Montf6eflo BUILDING SAFETY Lot 8 Block 3 - Edmonson Ridge Builder: JP Brooks 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. Proposed building elevations of lot corners. Proposed elevations at building corners. Proposed elevations on the side yard swales at the extension of building comers and high points. Proposed and as -built elevations of garage slab and lowest floor on walkouts. v% Top of curb elevation at the extension of property lines and center of driveway. Proposed elevations and location of any critical drainage ways located on the site natural or man-made) indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Must be installed prior to starting construction and maintained to be compliant withErosioncontrolCityrequirementsandprojectSWPPP. Follow City Standard Detail Plate 6006. Proposed driveway location, width at lot line, % of slope. Show proposed porches, cantilevers, bay windows, and decks (if being constructed). Show individual significant trees 36" DBH (Diameter Breast Height)or larger Existing or proposed retaining wall(s) top and bottom elevations. Show adjacent property topo related to drainage with arrows. Proposed sump pump outlet location on building footprint (natural drainage or piped to curb). Show any Drain Tile installed in the yard. 61 'Show sump pump location on final as -built City will accept only originals or quality hard copies of the as -built survey and certification of grading. ELEV PER GRADING PLAN Plans by Alliant. SETBACKS HOUSE TYPE 25' Front Slob on Grade Garage Floor Elev = 968.0 7' Side Lowest Floor Elevation = 9640 30' Rear ZONING Rear Elevation = 968.0 20' Side Street P.U.D. RAM - Rambler REFERENCE BENCHMARK: Rim of sanitary manhole on 86th St. DRIVEWAY AREA TO STREET: 832Y S.F. NE near West plot boundary. Elevation = 957.15 feet (Plot Datum) SOD AREA: Full Yard - 8/40Y S.F. PROPOSED HOUSE ELEVA TONS 30' Past House = 6100% S.F. Top of Foundation (Slab) Elev = 9674 Garage Floor Elev = 967.1 0 20 07SETS - PROPOSED IMPERVIOUS SURFACES Total lot Area = 10, 534'1- S.F. 60m" BU) 11: PROPOSED DING SURVEY House Area - 2,3427- S.F. " = SCALE: I20' 096.04 05/ 3: 965.59 OS14: 965.46 Approved twr- 5/16/2025 Drivewor& W Llh Area = 760% S.F. Total Impervious Area = 3,102'/- S.F. (29.4%) Certifica te of Survey for JP Brooks Builders Lot 8, Block 3, EDMONSON RIDGE City of Monticello, Wright County, Minnesota Addr"& 4626 86th St NE, Monik.ella MN W362 NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/29/2021, PAGES 22-24, BY ALLIANT ENGINEERING. 9 ` o a+ 965.5 .I r- rN A A A 1 A I i 0 5\I PID: 155-264-003090 59 $ OS2. 9 OS . 3 965.5 EEle . 966iect 6..04 g65 gN 89006'39'v E X g184.56 96966 965 68 U65T ) A65.6 965.2 44 10 g6" 1 > P Y2" 52.79 /k1/ - - ` 0 1 65 5 67.50 - - S - 2z - 64.27 44//0 / ---- - S I--- SB 9 --- - I- o - - - SB - - SBL - - - - - - -1 60 60. 00 65 6 965.3 g I 12 gN X I1296965k 4 X t Proposed rn House 12. 00 - 96-4.8 965•f` 2. 00 ,}r4526 -- - - - - 12'x/ 2' i 63.3 I C wJ 8 Patio `+ IPID: I55- 264-003080 g65 k I o 96 8 I • C rn L 9.5a 5 Area; 10534% S.F. o i 6 I 968 T 5 " 96 (0. 24Y Ac.) o 5.3 965 A 9 J fit" 7 xx-- ° 96 96 a+ 963.9 Proposed N965.3 Day I a8 Proposed 65.56.9X3Garage -30-963-o 477 =` Q1nr 2. 00 31. 50 ' J \ s ` 964.6 rn g659 l26kq 6a 9 V22.00 9. 4. 965. 59/2 . SBL' 15- - - - g6a' o M / 964. 4 X o - 36 N 3/,,55 23 W- e k• i X T ° 3z 3z - zx 2 0 6 7 /o fT2297 965.4 1 129.08 it pfi6' N 89 °06'39" E 1& 05 33 965.46 X 965•7 RI_ 9648 X Xg 66 Q PID: 155- 26/ r 4/ - 003070 d> 040'4 X 96A. 8 t SHEET NO. I 964. 0 Certificate of Survey BOGART, PEDERSON JP Brooks Builders & ASSOCIATES, INC. L8 B3 EDMONSON RIDGE LAND SURVEYING CIVIL ENGINEERING MAPPNG Wright County, Minnesota 3071 6 FIRST STREET, BECKER, MN 55308-9322 TEL: 763-262-8822 FAX: 763-262-8844 1 1 I L// L- I hereby certify that this survey, plan, or report was prepared by me or under my my direct supervision, and that I am a duly Licensed Land Surveyor under the lows of the State of Minnesota. Signed: Craig A. Wensmann Date: 5/12 25 Reg. No.47466 LEGEND: Denotes found iron monument E94_2.3] Denotes proposed elevation 6ro Denotes proposed drainage flow Denotes catch basinQ Denotes electrical cabinet Denotes water service per plan Denotes sanitary service per plan s Denotes electric service t Denotes watervolve Denotes telephone pedestal Denotes cable television box LS 44110 Denotes Peter Goers, LS I Denotes bituminous surface Denotes easement Denotes minor contour Denotes sanitary sewer Denotes waterline Denotes existing adjoiners SBL - Denotes building setback line IP y2 44110l I 96k.6 964.6 I I I DATE: 4/23/ 25 E DATE DESIGN BY: DRAWN BY: DM CHECKED BY: CAW DWG FILE: L8 B3 DP FILE NO.: 22- 0259.22 Drainage and Utility Easements are shown thus: L6 12 12 N.T.S. Being 6 feet in width and adjoining lot lines and 12 feet In width and adjoining street lines and rear lot lines as shown on this plot, unless otherwise shown. DESCRIPTION