Loading...
2024-02707CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS : 4532 86TH ST NE PIN ; 155264003090 LEGAL DESC : EDMONSON RIDGE LOT 009 BLOCK 003 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE : NEW CONSTRUCTION VALUATION : 307,361.46 NOTE: NEW CONSTRUCTION SINGLE FAMILY HOME: 0 SQ FT FINISHED BASEMENT 0 SQ FT UNFINISHED BASEMENT 1,948 SQ FT FINISHED MAIN FLOOR 42 SQ FT OPEN PORCH 534 SQ FT GARAGE FIREPLACE: YES A/C: YES MECHANICAL: 10 PLUMBING: 14 WATER METER I (MAIN) 1.00 SAC UNITS WAC UNITS 1.00 APPLICANT JP BROOKS HOMES 13700 REIMER DRIVE SUITE 100 MAPLE GROVE, MN 55311- 763) 999-7153 OWNER LSW INVESTMENTS LLC 4065 CHELSEA RD W MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date Bldg Official Date 2 0 2 4- 0 2 7 0 7* DATE ISSUED: 12/09/2024 Permit #: 2024-02707 1.00 BUILDING PERMIT FEE 2,288.90 PLAN REVIEW 1,487.79 STATE SURCHARGE, BLDG VAL 153.68 SAC FEE 30% 1,407.60 SAC FEE 70% 3,284.40 WATER ACCESS CHARGE, RESI 2,090.00 COMB CONNECTION FEE / RESI 130.00 SEWER / WATER EXCAVATION PERMIT 130.00 CONTRACTOR LICENSE VERIFICATION FEE 5.00 ASSESSMENT SEARCH FEE 50.00 UTILITY LOCATE FEE, RESI 50.00 WATER METER 1 (MAIN) 412.00 MN STATE SALES TAX (MTR1) 30.39 TOTAL 11,519.76 Payment(s) CHECK 22001 11,519.76 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY Of V C 201 -7/0MonticefloI: z tiUILL)ING SAFs I PERMIT ETY # i I 0 !' 2 9024 it 505 WALNUT STREET, SUITE 1 MONTIC LW, MN 55362 j City Hall (763) 295-2711 Building Inspections (763) 2.95-306 Fax (763) 295-4404 BUILDING PERMIT APPLICATION Please Print - INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED. SITE ADDRESS: L4J 0 a lU `n 5rV_ z2;;+ N r,, ZONED LEGAL: Lot Block Plat 56 (oLi 0(x__2A7)q1 y Property Owner Name: JP Brooks Builders Phone: 763-285-4790 Address: 13700 Reimer Drive City: Monticello State: MN Zip: 55311 Contractor Name: JP Brooks Builders Phone: 763-285-4790 State License #: 656554 E-Mail: shelly@jpbrooks.com Address: 13700 Reimer Drive City: Maple Grove State: MN Zip: 55311 Eng./Architect Name: Phone: Address: City: State: Zip: Plumber Name: Northwoods Plumbing Phone: 763-717-8757 Address: 30799 73rd Street City: Pierz State: MN Zip: 56364 Mechanical Name: Recher HVAC Phone: 612-802-6525 Address: 1125 Mississippi Drive North City: Champlin State: MN Zip: 55316 T oe of Work Type of Construction Building Information New X Single Family Use of building " " ,CAWCSL Addition Duplex of stories Alteration Multi - Family Floor area sq. ft. Ic1 v1g Repair Commercial Estimated value Move Industrial of construction $ 0 Other Other D scription of work: I hereby apply for a permit for construction as described and acknowledge that the information I have provided above is complete and accurate. I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Laws of the State of Minnesota; and that I understand that this application is not a permit and that the work is not to start without a permit. I further understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. SEE BACK FOR PLUMBING AND MECHANICAL INFO. Applicant Sig ture Application Date ll i, 7 APPLICANT: Please show fixtures that are applicahle. Fire Suppression : (if'applicable) Plumbing: (if applicable) Mechanical. (if applicable) No. Fixture Tvne No. Fixture Tvpe No. Fixture Tvpe Sprinkler Heads Water Closet (toilet) i Furnace Other /Special FS Device Bathtub 1 Gas Meter Lavatory (wash basin) Range Hood i Shower 1 Gas Range Kitchen Sink Water Heater Dishwasher 1 Air Conditioning 1 Laundry Tub Mech. Fireplace 1 Clothes Washer Bathroom(s) Exhaust Fan Fire Alarm: (if applicable) I Water Heater Air Exchanger Urinal jam_ Dryer No. Fixture Tvpe Drinking Fountain Gas Opening w/o Fixture Floor Drain Slop SinkofDevices Other Outside Faucet (Dave%je) Future Owner Information: Naive: Address: q TOTAL TOTAL FOR CITY USE ONLY Tree Ordinance Handout Yes No Other Handouts Yes No City: ADDITIONAL INFORMATION: Valuation: i 7, 3 e, t • ,Y6 State: Zip: Construction Type: 1'3 Occupancy Group: r lze- Phone #: Division: tl.0'Sr„ic Square Footage: 1, } l8..fr- ev •,c- of Stories: n n /(Z h !c r of Residential Units: A Maximum Occupancy: At4 Fire Sprinklers: Yes $d No Off -Street Parking Covered: Z Off -Street Parking Uncovered: Z Building Official ' G""[%n3/ BPT: / / CITYC7F- Monticello Address: Legal: New Residence: Permit Applicant: Crawl Space Unfinished Basement Area Finished Basement Area 2024 Residential Buildina Permit Calculator 4532 86th Street NE, Monticello MN Lot 09 Block 03 Edmonson Ridge Addn 1 = Yes 0 = No I House Type: Rambler, Slab On Grade 1 =Yes O=No I =Yes O=No Contractor: 1 Plan Review: I Owner: 0 Master Plan: 0 Master Plan Review = 25% offtildinz Permit Fee) 0 15.27 1,948 16.50 32,142.00 0 44.05 Main/First Floor Area 1,948 125.00 243,500.00 Second Floor Area 0 115.00 Detached Garage 0 60.00 Attached Garage 534 47.33 25,274.22 Garage Conversion to Living Space 0 47.44 Carport/Gazebo 0 30.90 Pole Barn 0 19.03 Shed - greater than 200 SF 0 40.00 Lean -to -Shed 0 13.25 Basement Finish Only 0 16.00 Remodeled Area 0 17.39 Porch (open) 42 36.97 1,552.74 Porch (3-Season) 0 60.00 Porch (3-Season on Existing Deck) 0 55.00 Porch (Screen Porch/Breezeway) 0 58.48 Solarium 0 94.90 Deck 0 20.00 Deck (Screen In & Roof Over Existing) 0 29.80 In -Ground Pool 0 23.18 Above -Ground Pool 0 11.31 Fireplace - Mechanical/Gas 1 4,892.50 4,892.50 Fireplace - Masonry 0 22, 660.00 Elevator/Lift/Other 0 CALCULATED BUILDING VALUATION $ 307,361.46 1 = Yes 0 = No Water Hook-up 1 Sanitary Sewer Hook-uD 1 FEES: BUILDING PERMIT - 1997 UBC FEE SCHEDULE PLUS 6% 2,288.06 PLAN CHECK 1,487.24 CONTRACTOR LICENSE VERIFICATION 5.00 STATE SURCHARGE 153.68 SUBTOTAL 3,933.98 SEWER FEE [SAC] 4,692.00 WATER FEE ]WAC] 2,090.00 WATER / SEWER CONNECTION FEE 130.00 SEWER/WATER EXCAVATION PERMIT FEE 130.00 ASSESSMENT SEARCH 50.00 UTILITY LOCATES 50.00 5/8" WATER METER & SALES TAX 442.69 SUBTOTAL 7584.69 TOTAL FEES CALCULATED Escrow Amount - (Winter Only) 11,518.67 TOTAL AMOUNT TO BE PAID TO CITY $ 119518.67 CITV OF A Monticello BUILDING SAFETY WIN RESIDENTIAL PLANS EXAMINING REPORT 505 Walnut Street, Suite 1 MONTICELLO, MN 55362 Date: l L - 3 '- 2-1oW City Hall (763) 295-2711 Building Inspections (763) 295-3060 JP Brooks 4532 86th Street NE Contractor: JP Brooks 13 700 Reimer Drive Maple Grove, MN 55311 Telephone: 763-285-4790 BASIC PROJECT DESCRIPTION: SOG with gas fireplace and luxury suite 1, 948 Sq ft Finished 1 Page Bldg Building, Mechanical & Plumbing Ron Hackenmueller— Chief Building Official Ron.Hackenmueller(a ci.nionticello.mn.us Bob Ferguson— Inspector / Fire Inspector Bob.Fer u son(a.ci.monticello.mn.us Wayne Kalla — Inspector/ Plan Reviewer Wayne.Kalla(a,ci.monticello.nin.us Mark Gerber — Inspector / Plan Reviewer Mark.Gerber(a ci.monticello.mn.us Amy Biren — Building Permit Technician bu i ldinizdenartment(aci.monticello.mn.us review Electrical Bill Husom — Electrical Inspector outside of city Permits I Minnesota Department of Labor and Industry mn. ov 910 — 18th St SE, Buffalo, MN 55313 CDD Land Use/Site Design/Landscaping Angela Schumann — Community Development Director Angela. Schumann(aci.monticello.mn.us Ron Hackenmueller— Zoning Administrator Engr/ Grading, Paving, Drainage & Matt Leonard- City Engineer PW Utilities Matt.Leonar&( ci.monticello.mn.us Ryan Melhouse — Project Engineer Rvan.Melhouse(a,ci.monticello.mn.us Mario Frucci — Engineering Technician Mario. Frucci(a,ci.monticello.mn.us Mat Stang - Water & Sewer Superintendent Mat. StanizAci.monticello.mn.us 763) 271-3253 763) 271-3214 763) 314 -0908 763) 271-3222 763) 295-3060 612)490-0488 Office Hrs: 7-8:30am 763) 271-3224 763) 271-3253 763)-271-3271 763) 271-3227 763) 271-3213 763)271-3274 The plan review accomplished as indicated in this record is limited to those code sections specifically identified herein. This record references commonly applicable code sections. It does not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those who are knowledgeable and capable of exercising competent judgment in evaluating construction documents for code compliance. The following notations refer to design submittal documents as presented in application for a building permit. This report is not to be considered conclusive with respect to review of plans and specifications to assure compliance with Minnesota Building Codes and Minnesota Fire Codes. Please retain a copy of this report on -site, attached to the Approved Job Copy of the Building Plans and Specifications. 2 1 Page This review is for Building Construction Permit review only. All other reviews will be conducted with their respective permit applications. See note #1 below. PLAN NO. DEPT SHEET/ SPEC. CODE SECTION COMMENTS SECTION 1 bldg n/a general All job debris must be contained on -site and, in a dumpster, or covered, fenced area note 2 bldg n/a general Building Official review and authorization required prior to changes, modifications, note or alterations. 3 bldg n/a general 1300.0220 NOTICE: This building must not be occupied until a Certificate of Occupancy has note been issued. 4 bldg n/a general Final Building, Plumbing, and Heating inspections must be completed prior to note occupancy. Owner or contractor must be present for final building inspection. 5 bldg n/a general IFGC 406 Gas piping pressure test required: 25# for 10 minutes on residential construction. note 6 Bldg n/a general Separate applications and permits Required for Sewer / Water Connection, Heating note A/C Systems, Plumbing, Fire Alarm Systems. bldg n/a general MR 1322.1101 A building certificate, showing energy code compliance information, must be posted 7 note Subp 15 in a permanently visible location prior to final inspection N 1101.8) bldg MN Statute Carbon monoxide detectors must be installed in accordance \vith MN Statute §299F 8 299F .50 50 R315 bldg Buildings must be constructed per current building codes. 2020 MN State Building Code including: n/a general 0 2020 MN Residential Code 9 note M R 1300 2023 National Electrical Code 2020 MN Plumbing Code 2020 MN Mechanical Code 2020 MN Fire Code bldg All bottom wall plates in contact with concrete or masonry shall be decay resistive. 10 R317 All metallic fasteners and mechanical connections in contact with ACQ pressure treated lumber must be approved for such use. 11 bldg IRC 602.10 Walls shall be braced in accordance with IRC 602.10 or Engineered Plans 12 bldg n/a general Post Address Card Visible from the street, maintain until the house numbers are note installed. 13 bldg n/a general Engineered Roof Trusses: Provide a Copy of the Approved, Certified Truss Plans note for framing inspection. 14 bldg n/a general State Board of Electricity: Separate Permit and Inspections Required for Electrical note work. 15 bldg Maintain 6" Earth to wood separation Eng Erosion Control Required: Install erosion control per proposed survey prior to 16 foundation inspection. Rock construction entrance and site perimeter controls such as silt fence are required. Maintain erosion controls until landscaping is completed. 3 1 Page PLAN NO. DEPT SHEET/ SPEC. SECTION bldg 17 18 bldg 19 hhk hl. 20 h 21 h/d 22 hld,, hld 23 24 25 26 hld 27 28 29 30 31 32 33 34 35 36 37 hlcl• I hld r hlrh h /d blcl,, bldg bldg bldg bldg CODE SECTION COMMENTS Vent Pipes: The vent pipe shall be primed and glued at all fittings and shall extend up from the radon control system's collection point to a point terminating a minimum of 12" above the roof. The vent pipe shall be located at least 10' away from any window or other opening into the conditioned spaces of the building. Vent pipes routed through unconditioned spaces shall be insulated with a minimum of R-4 insulation. Vent pipes within the conditioned envelope of the building shall not be insulated. R312.2 Window Fall Protection Required for all windows 6' above grade with sill height of less than 24", maximum opening must be less than 4". WARNING: Call Before You Dig! Gopher State one 651-454-0002 Blower Door Test Required: Prior to final Inspection — Air Leakage Rate Must Not Exceed 3 Air Exchanges Per Hour. Flash between House and Stoop. R319.1 Install House Numbers: 4" minimum, visible from street. Fireplaces: Must be inspected prior to wall enclosure or when smoke chamber / damper areas are exposed. Solid Block Between Wall Studs at Vaulted Truss Bottom Chord. R302.11 Fire blocking Required: Cut off concealed draft openings between stories and attic. Close horizontal to vertical penetrations. R301.1 Carry Concentrated loads to foundation — Concentrated loads must be solidly blocked and carried continuously to foundation. Slope garage floor to Overhead door or to floor drain. (no trap / dry pan drains to daylight; schedule 40 pipe required). R402.4.1.1 Hardboard Backer Required behind tub / shower. Seal and Secure Sump Pump Basket Cover. R506.2.3 Vapor Retarder: Required Under Floor Slab (Exception unheated spaces). R405.2.3 Fain Tile to Sump Basket: Install pump with rigid piping to house exterior. Install flexible hose connection extending to drainage area away from the foundation wall. R1303.2402 Provide power receptacle & switched light in attic or other unconditioned space for Subpart 6 future active radon ventilation system. Radon gas vent pipes shall be provided with space around the vent pipe for future fan R 1303.2402 installation. The space required for the future fan installation shall be a minimum of 24 in diameter, centered on the axis of the vent pipe, and shall extend a minimum distance of 3 vertical feet. R 402.1.1.3 Poly Slip Sheet Required over non -draining insulation. R802.11 Install truss clips at each truss and girder end unless otherwise specified by the truss manufacture. R402.2.3 For air permeable insulations in vented attics, a baffle shall be installed adjacent to MN Res.Energy soffit and eave vents. The baffle shall extend over the top of the attic insulation. code R703.2 Install weather barrier / House Wrap: Cover all exterior wall sheathing (exception: Detached Accessory Buildings) 4 1 Page PLAN NO. DEPT SHEET/ SPEC. SECTION bldg 38 39 bldg 40 zoning CODE COMMENTS SECTION i" Anchor Bolts or Manufactured Foundation Straps Must: Engage 2nd course of R403.1.6 concrete block masonry. Be located at each core fill / be spaced 6' on center, 2 anchors per plate, 1 anchor within V of each end. Exterior non -draining foundation insulation requirements: have a rigid, opaque, and weather -resistant covering to prevent degradation of the insulation's thermal R 4021.1.3 performance. The protective covering shall cover the exposed exterior insulation and extend a minimum of 6" below grade. The insulation and protective covering system shall be flashed in accordance with IRC section R703.8. DRIVEWAY REQUIREMENTS: R-1 zoning code The Maximum Width at the Property line Shall Not Exceed 30 Ft. and Shall Taper to a width Not to Exceed 28 Ft. and the Public Street. 5 1 Page New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution I Date Certificate Posi panel. Place yourMailingAddressoftheDwellingorDwellingUttCity D ' Yost-- MCA v1 I (A 0 logo here Name of Residential Contractor MN License Number JP Brooks Builders BC 686554 THERMAL ENVELOPE CITY pF .. _-_... .. _ Monticello 991LOtNG SAFETY APPROVED FILE COPY e REVIEWED FOR CODE COMPLIANCE SUBJECT TO FIELD INSPECTION Date:__ - - P.- -4 Insulation 11ocationre: Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope airtightness: Windows & Doors Average U-Factor (excludes skylights and one door) U: 12828 ffiSolarHeatGainCoecient (SHGC): MECHANICAL SYSTEMS Appliances Heating System Fuel Type Nat. Gas Manufacturer I Bryant Model 915SBO4206OE17 0 a a M NA R-15 R-15 R-30 R-30 R-21 R-48 R-48 R-30 NA RADON CONTROL SYSTEM Type: Check All That Apply E Passive (No Fan) Active (With fan and monometer a) U C cu Q 3 n U o Q m m O cno Z CU N U 0 CD 0) E c m 0 M o Z U_li ti m or other system monitoring device) y U) Location (or future location) of Fan: 72 Co a Attic O U a a) 0 3 c m c CL IL X O O m w 14 E o c LL 2 i2 m it Other Please Describe Here Poly Barrier 4ExteriorandInteriorasdictatedby code Interior of foundation wall Duct system air tightness: I NA Heating or Cooling Ducts Outside Conditioned Spaces Not applicable, all ducts located in conditioned space R- value Domestic Water Heater Nat. Gas Richmond Input in Capacity Rating or Size I BTUS: 60,000 Iin Gallons: 150 AFUE or Efficiency I HSPF% 96.2 190 Heating Loss Heating Gain Residential Load Calculati 7 LION a45 I MECHANICAL VENTILATION SYSTEM I Make-up Air Select a Type Cooling System Not required per mech. code Elect. I F ] IBryant Flowered BA013NR0306NG F]Describe: Interlocked with exhaust device. output 2.0 111-11 Other, describe: in Tons: SEER 13 I Location of duct or system: EER Cooling Load I Ll C I Cfm's round duct OR metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Heat Recover Ventilator (HRV) Capacity in cfms: Low: (High: Energy Recover Ventilator (ERV) Capacity in cfms: Low: I90 High: 1130 nBalanced Ventilation capacity in cfms: Location of fan(s), describe: IBathrooms and Laundry Capacity continuous ventilation rate in cfms: 90 -130 Total ventilation (intermittent + continuous) rate in cfms: 1270 Combustion Air Select a Type Not required per mech. code Passive Other, describe: Location of duct or system: Mechanical Room I Cfm's s " round duct OR I" metal duct Builders Associaton of Minnesota version 101014 Recher HVAC HVAC Load Calculations for 4532 86th Street NE Prepared By: Tuesday, October 8, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rvahvahc - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC L P1Y_M%& _MN-_55441 _ _. Page 2 ' Project Report General Project Information Project Title: Recher HVAC Project Date: Tuesday, October 8, 2024 Client Name- 4532 86th Street NE Design Data_ Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hurn Bel.Hum Dry Bulb Difference Winter: -15 -15 n/a n/a 72 n/a Summer: 88 71 44% 50% 75 24 Total Building Supply CFM: 649 CFM Per Square ft.: 0.333 Square ft. of Room Area: 1,948 Square ft. Per Ton: 1,363 Volume (ft'): 17,531 I_ Building Loads -- - Total Heating Required Including Ventilation Air: 40,245 Btuh 40.245 MBH Total Sensible Gain: 14,325 Btuh 84 % Total Latent Gain- 2,824 Btuh 16 % Total Cooling Required Including Ventilation Air: 17,149 Btuh 1.43 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plvmouth, MN 55441 Miscellaneous Report System 1 House Input Data -- Winter: Summer - Duct Sizing Inputs Calculate: Use Schedule. - Roughness Factor Pressure Drop: Minimum Velocity: Maximum Velocity Minimum Height: Maximum Height: Outside Air Data Infiltration Specified: Infiltration Actual: Above Grade Volume Total Building Infiltration: Total Building Ventilation: Elite Software Development, Inc. Recher HVAC Page 3 Outdoor Outdoor Outdoor Indoor Indoor Grains 1 Dry Bulb Wet Bulb Rel.Hum Rel.Hum Drv_ Bulb Difference 15 15 100% n/a 72 n/a 88 71 44% 50% 75 23.51 Main Trunk Yes Yes 0.00300 0.1000 in.wg./100 ft. 0 ft./min 900 ft./min 0 in. 0 in. Winter 0.380 AC/hr 111 CFM 0.380 AC/hr X 17,531 Cu.ft. 6,662 Cu.ft./hr X 0.0167 111 CFM 85 CFM Runouts Yes Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min 0 in. 0 in. Summer 0.200 AC/hr 58 CFM 0.200 AC/hr X 17,531 Cu.ft. X 0.0167 3,506 Cu.ft./hr 58 CFM 85 CFM System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified.- 0.380 AC/hr (111 CFM), Construction: Average Summer Infiltration Specified: 0.200 AC/hr (58 CFM), Construction: Average auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\--UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Elite Software Development, Inc. Recher HVAC Plymouth. MN 55441 Page Load Preview Report Net ft.' Sen Lat Net Sen; Sys; Htg Sys Cig Sys Act Duct Scope Ton rronI Area Gain Gain Gain Lossl CFM! CFMI CFM Size Building 1.43 1,363 1,948 14,325 2,824 17,149 40,245 496 649 649 Svstem 1 1.43 1,363 1,948 14,325 2,824 17,149 40,245 496 649 649 1Ox1 Ventilation 472 1,318 1,790 3,157 Zone 1 1,948 13,853 1,506 15,359 37,088 496 649 649 1Ox1 1-Main Level 1,948 13,853 1,506 15,359 37,088 496 649 649 6— auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\—UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential S Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recker HVAC Plvmouth. MN 55441 Paae 5 Duct Size Preview Room or 'Source I Minimum Maximurrj Rough] Design SP Duct Duct' Htg Clg Act. , Duct Duct Name ! _ Velocity Velocitq Factor' L/10d Loss Velocity Lengtl j Flaw FIQw _ FIQw Size Svstem 1 Supply Runouts Zone 1 1-Main Level Built -In 0 750 0.01 0.1 404.7 496= 649 6-7 Other Ducts in System 1 Supply Main Trunk Built -In 0 900 0.003 0.1 718.9 496=, 649 10x1 Summary System 1 Heatina Flow: 496 Coolina Flow: 649 auerfiiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTL0.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth. MN 55441 Total Buildin-g Summary Loads Component ------------ ---- --- Description_ __ __- Marvin: Glazing -Marvin, U-value 0.34, SHGC 0.32 11 P: Door -Metal - Polyurethane Core, U-value 0.29 12F-Osw: Wall -Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 22D-10pm: Floor -Slab on grade, Vertical board insulation covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavv dry or light wet soil, U-value 0.343 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 111, Summer CFM: 58 Ventilation: Winter CFM: 85, Summer CFM: 85 Exhaust: Winter CFM: 85, Summer CFM: 85 AED Excursion: Total Building Load Totals: Area Sen uan ---- Loss - 221 6,540 42 1,060 1663 9,404 1947.9 3,389 214 6,386 26,779 3 0 0 10,309 3,157 0 40,245 Elite Software Development, Inc. Recher HVAC Pa Lat Sen Total Gain ---- Gam G 0 6,048 6,048 0 292 292 0 1,438 1,438 0 1,870 1,870 0 0 0 0 9,648 600 690 0 1,200 0 0 0 906 811 1,318 472 0 1,504 2,824 14,325 9,648 1,290 1,200 0 0 1,717 1,790 1.504 17,149 c-he-Ck Figures Total Building Supply CFM: 649 CFM Per Square ft.: 0.333 Square ft. of Room Area: 1,948 Square ft. Per Ton: 1,363 Volume (ft3): 17,531 Building Loads - ------__-- - Total Heating Required Including Ventilation Air: 40,245 Btuh 40.245 MBH Total Sensible Gain: 14,325 Btuh 84 % Total Latent Gain: 2,824 Btuh 16 % Total Cooling Required Including Ventilation Air: 17,149 Btuh 1.43 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential & Light Commercial HVAC Loads Auer Steel (Plymouth) ' PI m uth. MN 55441 Buildinq Pie Chart Floor 16% Roof 8% Wall 23% Roof 11 % Wall 8% Glass 35% Ventilation 8% Elite Software Development, Inc. Recher HVAC Page 7_ Infiltration 26% Door 3% Glass 16% AED Excursion 9% Ventilation 10% Infiltration 10% Equipment 7% People 8% Door 2% auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLOA9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth) Recher HVAC Plvmouth. MN 55441 Paae 8 Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) G neral Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 44.3 ft. System Number: 1 Room Width: 44.0 ft. Zone Number: 1 Area: 1,947.9 sq.ft. Supply Air: 649 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.2 AC/hr Volume: 17,531 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 6 Actual Winter Vent.: 85 CFM Runout Air: 108 CFM Percent of Supply.: 13 % Runout Duct Size: 7 in. Actual Summer Vent.: 85 CFM Runout Air Velocity: 405 ft./min. Percent of Supply: 13 % Runout Air Velocity: 405 ft./min. Actual Winter Infil.: 111 CFM Actual Loss: 0.083 in.wg./100 ft. Actual Summer Infil.: 58 CFM Item Area U- Htg Sen Cig Lat Sen Description Quantity Value HTM _ Loss HTM Gain Gain E -Wall-12F-Osw 40 X 9 288 0.065 5.7 1,629 0.9 0 249 S -Wall-12F-Osw 67 X 9 599 0.065 5.7 3,387 0.9 0 518 W -Wall-12F-Osw 40 X 9 235 0.065 5.7 1,329 0.9 0 203 N -Wall-12F-Osw 67 X 9 541 0.065 5.7 3,059 0.9 0 468 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E-Door-11 P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -GIs-Marvin shgc-0.32 0%S (2) 30 0.340 29.6 888 34.3 0 1,030 S -GIs-Marvin shgc-0.32 0%S 4 0.340 29.6 118 19.0 0 76 W -GIs-Marvin shgc-0.32 0%S (3) 45 0.340 29.6 1,332 34.3 0 1,545 W -GIs-Marvin shgc-0.32 0%S (2) 35 0.340 29.6 1,036 34.3 0 1,202 W -GIs-Marvin shgc-0.32 0%S (2) 25 0.340 29.6 740 34.3 0 858 W -GIs-Marvin shgc-0.32 0%S 20 0.340 29.6 592 34.4 0 687 N -GIs-Marvin shgc-0.32 100%S 20 0.340 29.6 592 10.5 0 210 N -GIs-Marvin shgc-0.32 100%S 42 0.340 29.6 1,242 10.5 0 440 UP-Ceil-16B-50 44.3 X 44 1947.9 0.020 1.7 3,389 1.0 0 1,870 Floor-22D-10pm_214 ft..Per. - -_ 21.4.- 0.343 29.8 _ 6,386 0 0. __ 0 0 Subtotals for Structure: 26,779 0 9,648 Infil.: Win.: 111.0, Sum.: 58.4 1,926 5.353 10,309 0.421 906 811 AED Excursion: 1,504 People: 200 lat/per, 230 sen/per: 3 600 690 Equipment- 0 1,200 Room Totals: 37,088 1,506 13,853 auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM Rhvac - Residential 8 Light Commercial HVAC Loads Auer Steel (Plymouth) Plymouth, MN 55441 Svstem 1 Room Load Summary Htg Min Run RoomArea Sens Htg Duct No Name _ _ ---- - SF-_-- 1--- Btuh _—_ _ CFM Size-_ Zone 1 Main Level 1,948 37,088 496 6-7 Ventilation 3,157 Svstem 1 total 1,948 40,245 496 System 1 Main Trunk Size: 10x13 in. Velocity: 719 ft./min Loss per 100 ft.: 0.097 in.wg Elite Software Development, Inc. Recher HVAC e 9 Run Clg Clg Min Act l Duct Sens Lat CI9 SysY Vel Btuh Btuh CFM CFM 405 13,853 1,506 649 649 472 1,318 14,325 2,824 649 649 L(ooling System_ Summary_ Cooling Sensible/Latent Sensible Latent TotallTons- -- - Split- -- - -Btuh - - ----_Btuh- - -- Btuh Net Required: 1.43 84% / 16% 14,325 2,824 17,149 Equipment Data Type: Model: Indoor Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: Heating System Cooling System Natural Gas Furnace Standard Air Conditioner 0 AFUE 0 0 Btuh n/a n/a 0 SEER 0 0 Btuh 0 Btuh 0 Btuh auerfiles\FILES\Hydronics\Load Calcs\Load Calcs (Program)\-UNTTLO.rh9 Tuesday, October 8, 2024, 3:45 PM CITY OF Monti do BUILDING SAFETY 4532 86th St NE Lot 3 Block 9 - Edmonson Ridge Builder: JP Brooks Builders 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 CITY OF MONTICELLO PROPOSED BUILDING SURVEY REQUIREMENTS CHECKLIST Prior to excavation and construction, the permittee shall submit to the City of Monticello through certificate of survey that the proposed construction is in compliance with all land use, zoning, conditional use, or planned use as part of the building permit application. The certificate of survey shall be signed by a registered Minnesota land surveyor. The signed certificate of survey shall contain at a minimum the following information: I.,/ Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. Proposed building elevations of lot corners. Proposed elevations at building corners. Proposed elevations on the side yard swales at the extension of building corners and hiqh points. Proposed and as -built elevations of garage slab and lowest floor on walkouts. To of curb elevation at the extension of property lines and center of driveway * Show on final p p p y y- as -built Proposed elevations and location of any critical drainage ways located on the site natural or man-made) indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Erosion control *Must be installed prior to starting construction and maintained to be compliant with City requirements and project SWPPP. Follow City Standard Detail Plate 6006. Proposed driveway location, width at lot line, % of slope. *P eed 1 d driveway slope not to Show proposed porches, cantilevers, bay windows, and decks (if being constructed). N/A Show individual significant trees 36" DBH (Diameter Breast Height)or larger N/A Existing or proposed retaining wall(s) top and bottom elevations. S/ Show adjacent property topo related to drainage with arrows. Proposed sump pump outlet location on building footprint (natural drainage or piped to curb). Show any Drain Tile installed in the yard.---* *Show sump pump location on final as -built City will accept only originals or quality hard copies of the as -built survey and certification of grading. v Z a a o 1 p v u a J W a Z LL o 0 c w O LL 1 F lL V o Z a W W U W m N N IQ lPS'21, --- 47466 1:..I Pr( Pr, o I 965j Proposed House I 966'0 647 14548 I X65. 2 grPerDevPlan9I BPAJobNo. 14 S I (22-0259.15) I I I P/ D: 155-264-003100 L 0 A6A 6 OS,f2 9rO P 965. 57 D% r 910 `'63-- 965.N 0e0 39w E\\ l 92 i `\ w g65 5 sST , 9651 34. 81 b 2*- 67.00 2x-g65.4 _?X 2X - 97.11 965.E N -_ ------ ;- Sgc--\ 9 967.3 147. 6I 67.00 965 3 5X y 6.8 3 ro(1 J2 b ropos 965.3 ° a $ 64. 2 vewoy Propos d op 964. 9 lOX 5 Garage g 45. 5 Proposed rn LJ N X House P/D /55-264-003090 B £ 1 to 14532 X Area: ll, 972Y- S.F. E o / 2. 00 5 y . ( 0.27% Ac.) fi > m n 966 12 7 1 5 65 4 0 55. 00 12.00 - c p.+ 12 9h - ----- x c o o _ - - - 96s r j96T2-94.40- 65.6 `O 96q.9 23. 16.,,,c 2a 67.00 2X 'S l \ l •Q 96 I D LL11' K' N - 06 " E 09 965.42 Q 1 h OS13 p, 965.75 I hrn 644 \\ X9r I X5. 4 9 g65.6 .. 965.4 965 8 a P/ D: 155-264-00308;;0 0i I IP Ss" Cop Rem JP • 1 r` 44110 PROXCT BENCHMARK: Top of hub w/tack at most NW'ly building corner offset Elevation - 965.60 feet (Plat Datum) Drainage and Utility Easements are OFFSETS OS,}'# 1=9965..60(BM) shown thus: L- 6 OS12= 965.57 OSfJ= 965.75 6 F- OS#4=965.42 12 I 12 N. T.S. Being 6 feet in width and adjoining lot lines and 12 feet in width and adjoining street lines and rear lot lines as shown on this plat, unless otherwise shown. SETRAC` K_ S HOUSE TYPE 25' Front Slab on Grade/Garage left 7' Side "The Waterford" 30' Rear Z01VING 20' Side Street P.U.D. QMvFwAY AREA TO STREET: 650% S.F. (Excluding sidewalk) SOD AREA: Full Yard - 9.105% S.F. 30' Behhd House - 5,029% SF. Total lot Area = 11,972Y S.F. House Area - 2,524Y- SF. DrlvnwgyAfa/ k Area = 701 SFF, Total Impervious Area = 3,225% SF. (26.9X) ELEV PER GRADING PLAN Plans by Alliant. Garage Floor E/ev - 968.0 Lowest Floor Elevation - 96LO Rear Elevation - 968.0 RAM - Rambler REFERENCE BENCHMARK: Rim of sanitary manhole on 86th St. NE near West plot boundary. Devotion - 957.15 feet (-"lot Datum) PROPOSED HOUSE ELEVATIONS Top of House Foundation Elev = 967.8 Garage Floor Elev = 967.5 SHEET NO. I Certificate of Survey BOGART, PEDERSON JP Brooks Builders & ASSOCIATES, INC. L9, 133, EDMONSON RIDGE LAND SURVEYING CIVIL ENGINEERING DMAGWright County, Minnesota 3076 IFIRST STREET, BECKER, MN 55308-9322 TEL: 763- 262-8822 FAX: 763-262-8844 55 55 Certificate of Survey for JP Brooks Builders Lot 9, Block 3, EDMONSON RIDGE City of Monticello, Wright County, Minnesota Ad*ww 4532 86TH STREET ALE Mondbefl MN 55362 NO EXCAVATION OR CONSTRUCTION CAN BEGIN UNTIL THIS PLAN IS APPROVED BY THE LOCAL BUILDING INSPECTOR LOWEST FLOOR ELEVATION IS SUBJECT TO SOIL AND WATER TABLE CONDITIONS. BEARING AND DISTANCE INFORMATION IS PER THE RECORDED PLAT. EASEMENTS ARE SHOWN PER RECORDED PLAT UNLESS OTHER DOCUMENTATION WAS PROVIDED TO US. CONTRACTOR TO DETERMINE EXACT LOCATION AND ELEVATION OF SEWER SERVICE. THE LOWEST FLOOR ELEVATION IS SUBJECT TO THE ACTUAL DEPTH AND ELEVATION OF THE SEWER SERVICE. PRIOR TO ANY EXCAVATION, EXCAVATOR MUST COMPARE SURVEY WITH HOUSE PLAN AND BUILDER TO VERIFY TYPE OF HOUSE, DIMENSIONS AND FINAL ELEVATION(S). STREET AND UTILITY IMPROVEMENTS SHOWN PER PLAN. UTILITIES SHOWN HEREON WERE DIGITIZED PER THE EDMONSON RIDGE DEVELOPMENT PLANS DATED 7/29/ 2021, PAGES 22-24, BY ALLIANT ENGINEERING. LEGEND: Denotes found Iron monument Denotes set loth x 976.4 Denotes existing ground elevation 942. Denotes proposed elevation f - Denotes proposed drainage flow PROPOSED DING SURVEY ® Denotes water service per plan r ® Denotes sanitary service per plan Appfoved Date 11 / 28/2024 • Denotes sanitary manhole Denotes catch basin X 0 30' SCALE: 1" = 30' I hereby certify that this survey, plan, or report was prepared by me or under my my direct supervision, and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Signed: Craig A. Wensmann Date: 10L_ LL24 Reg. No. 47466 H Denotes watervalve LS 44110 Denotes Peter Goers, LS LS 47466 Denotes Craig A. Wensmann, LS IDenotes bituminous surface Denotes gravel surface Denotes easement 060 Denotes contour per grading plan Denotes sanitary sewer per plan Denotes waterline per plan SBL - Denotes building setback line Denotes existing adjolners DATE: 10/24/ 24 E DATE DESIGN BY: DRAWN BY: CK CHECKED BY:CAW DWG FILE: L9 83 HS FILE NO.: 22- 0259.16 DESCRIPTION