Loading...
2020-00026CITY OF MONTICELLO AS-BUILT SURVEY REQUIREMENTS CHECKLIST Upon completion of the final lot grading, the permittee shall submit to the City of Monticello certification that the final lot grading is in compliance with the approved site grading plan as part of the building permit. The certification shall be signed by a registered Minnesota land surveyor. The certification shall contain at a minimum the information: Indicate permanent iron monuments at each lot corner. Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks, lakes, and Type 4 and 5 wetlands. As-built elevations of lot corners. As-built elevations at building corners. As-built elevations on the side yard swales at the extension of building corners and high points. Proposed and as-built elevations of garage slab and lowest floor on walkouts. Top of curb elevation at the extension of property lines and center of driveway. Elevations and location of any critical drainage ways located on the site (natural or man-made) indicated with drainage arrows and percentage of slope. Label all adjacent street and railroad right-of-way. Erosion control and required landscape finishes (sod, grass, trees). Driveway location, width at lot line, % of slope. Show decks, porches, cantilevers and bay windows. Show individual significant trees 36” DBH (Diameter Breast Height)or larger Retaining wall top and bottom elevations. Show adjacent property topo related to drainage with arrows Sump pump outlet location on building footprint (natural drainage or piped to curb) Show any Drain Tile installed in the yard. City will accept only originals or quality hard copies of the as-built survey and certification of grading. 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404 4147 87th st NA NA 7187T HSTREE T N MV Q Ll 0 d 0 a m 0 a d O 9'-0" x 8'-0" OVI1D. DR. FRONT ELEVATION CORBELS c`a, ; z t- ;, 12 6 FRONT TO REAR DISCLAIMER IN PREPARATION OF TI11S PLAN EVERY ATTEMPT f1AS BEEN MADE TO AVOID MISTAKES. DESIGNER CANNOT UARANTEE AGAINST 11UMAN ERROR. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS AND BE RESPONSIBLE FOR TI1E SAME. TIIESE DESI NS, CONCEPTS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND AS SUC11 REMAIN TI1E EXCLUSIVE PROPERIY OF COUNTRY LUMBER AND ARE NOT TO BE COPIED WITIIOUT TI1E WRITTEN CONSENT OF COUNTRY LUMBER. MAINTENANCE FREE SIDIN TRiM p { l_ j., :; , ss Dwfi"S 4= I'-0 W rr, L _ n a.,,: a u,.; AQpRCi lCi7 L GOPY REVIEW@q Ffiri COOE ONiALIAfdCc SUBIECTT!,FtE!.GlNS fCT40i a atc: " y_ __ _.__._ __ ._. ' oTUYP_: m m m o o a- d- 6' o Z N U 0 1w IAI r' Z o N N V N O 4J MN 0Q •' o O a 0 N N OF 5 i:s7:,:.. .. _ D/'l(1G \/GAITG AG DG llf1 IVI/ \IIV I LIV/ \IVI../L 1 1\LL SIDING TRIM REAR ELEVATION I/8"= I'-0" IVIr\IIVILIVrIIVIiL I I\LL SIDIN Tf IM LEFT ELEVATION I/8" = I '-0" 12 12 SiuiNv i KiM RIGhT ELEVATION I /8" = I '-0" I`keil)YI cVLsa Flfl3 ,...-- lP6 R t Ep FIIE COPY a REVIEV ED POR CODE COMPLIANCE Ij c ,U IF ',.. Iz_' i,S'=5PECTION a Date: igr":aii,rc. .,. Y JhMr i _ N O 0 N N N d- N N 54'_0" 4'-0" 28'-0" 22'-0" 110LD FOUNDATION IN 2" 7_ 4_p FOR EXTERIOR INSUL _ 5_g g_3 6068 SLIDING CSMT. 2636 W/ SLDR_5036 ______ PATIODR_______ EGRESSWELL_ 8'-0" SLDR. 5036 W/ EGRESS WELL c c 54'-0" I NOTES: I ) 11EADERS AT EXTERIOR DOORS WINDOWS TO BE SIZED BY SUPPLIER 2) SMOKE DET CTORS AS 'I REQ'D PER CODE ' 3) SLIDING WINDOWS UNIT SIZES INDICATED IN INCIIES)- VERIFY WINDOW MANUF. W/ BUILDER 4) FRAMER TO ROCK COMMON WALLS I N GARAGE 5) ALL INTERIOR WALL 24" O.C. EXCEPT IN KITCIIEN SUPPORTING CABINETS 6) KITCIIEN WALL SUPPORTING CABINETS @ I 6" O.C. N SFT. (GARAGE) I /4"= I '-0" t - - , ' . . . ENGINEERED ROOF i RUSSES W/ ENERGY 11EEL @ 2'-0" O.C. I /2" WAFER BD. 511T. I 5# FELT ICE WATER Si11ELD ASPf1ALT S111NGLES 2x6 SUBFASCIA ALUM. SOFFIT FASCIA CONT. SOFFIT VENT RIGID WIND WAS11 BARRIER AI R Cf1 UTE 2x6 @ I 6" O.C. R-21 FIBER L. INSUL. VAPOR BARRIER 7/ I 6" 05B StiT. OR 3/4" FIBER BD. S11TG. I /2" 6YP. BD WALLS MAINT. FREE SIDING I 2 CRS. I 2" CONC. BLK. 20" x 8" CONC. FTG. RI ID INSUL. R Q r# VAPOR BF RR!ERS WATERPROOFING G J PROVIDE 24" x 36" AREA FOR , x FUTURE FAN FOR RADON ` SYSTFM ;° 5/8" GYP BD. CLG. VAPOR BARRIER R-49 INSUL. 2x I 0 FLR. JSTS @ I 6" O.C. 3/4" T WAFER GLUED SCR WED SPR' FOAM RIM II II II II N II ii CONC. FLR. SLAB - n SEAL ALL LOOR PENETRATI NS SUMP BASKET W/ 6 MIL POLY TAPED 4" OF GRAVEL SEALED LID. 3" VENT @( I 2" MIN. LAP) PIPE TO VENT OUT ROOF AND SEALED I 8" FLR TRUSSES @ I 9.2" O.C. 3/4" T G WAFER GLUED SCREWED 5/8" GYP. BD. 4" CONC. FLR. SLAB I CRS. 6" CURB. BLK. 7 CRS. I 2" CONC. BLK. 20" x 8" CONC. FTG. RIGID INSUL. C 8 VAPOR BARRIERS WATERPROOFING C BUILDING SECTION SEE BUILDERS SPECIFICATION FOR BUILDING MATERIALS STAIR INFORMATION 3-2x I 2 STRINGERS 7 3/4" MAX. RISERS I 0" MIN. TREADS 6'_8" MIN. NEAD CLEARANCE. 11ANDRAIL TO BE 34" TO 38" NIG11 ENDS ARE TO BE RETURNED. ROOF VENTILATION RATIO I SF. IN 200 SF. 50 % ROOF 50 % SOFFIT NOTE: CAULK FLAS11 AROUND ALL EXTERIOR OPENINGS 2x6 TREATED SILL PLATE I /2" ANCIIOR BOLT @ 6'-0" O.C. SILL SEALER ouo a' t,di i Y I:.l_".l:' . eu:lowa 9afei° t tP C1df FILE PY m REVI Vv"c['. rGR 6 JE COMPLIANCE n SUB1er7 T': lEIC II SPCCTIGiV I E _ . . _.. J 3/8" = I '-0"