2020-00026CITY OF MONTICELLO
AS-BUILT SURVEY REQUIREMENTS CHECKLIST
Upon completion of the final lot grading, the permittee shall submit to the City of Monticello
certification that the final lot grading is in compliance with the approved site grading plan as
part of the building permit. The certification shall be signed by a registered Minnesota land
surveyor.
The certification shall contain at a minimum the information:
Indicate permanent iron monuments at each lot corner.
Dimension from house to lot lines and from O.H.W. & Bluff Line of rivers, creeks,
lakes, and Type 4 and 5 wetlands.
As-built elevations of lot corners.
As-built elevations at building corners.
As-built elevations on the side yard swales at the extension of building corners and
high points.
Proposed and as-built elevations of garage slab and lowest floor on walkouts.
Top of curb elevation at the extension of property lines and center of driveway.
Elevations and location of any critical drainage ways located on the site (natural or
man-made) indicated with drainage arrows and percentage of slope.
Label all adjacent street and railroad right-of-way.
Erosion control and required landscape finishes (sod, grass, trees).
Driveway location, width at lot line, % of slope.
Show decks, porches, cantilevers and bay windows.
Show individual significant trees 36” DBH (Diameter Breast Height)or larger
Retaining wall top and bottom elevations.
Show adjacent property topo related to drainage with arrows
Sump pump outlet location on building footprint (natural drainage or piped to curb)
Show any Drain Tile installed in the yard.
City will accept only originals or quality hard copies of the as-built survey and
certification of grading.
505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404
4147 87th st
NA
NA
7187T
HSTREE
T
N
MV
Q
Ll
0
d
0
a
m
0
a
d
O
9'-0" x 8'-0" OVI1D. DR.
FRONT ELEVATION
CORBELS
c`a, ;
z t- ;,
12
6 FRONT TO REAR
DISCLAIMER
IN PREPARATION OF TI11S PLAN EVERY
ATTEMPT f1AS BEEN MADE TO AVOID
MISTAKES. DESIGNER CANNOT UARANTEE
AGAINST 11UMAN ERROR. CONTRACTOR TO
VERIFY ALL DIMENSIONS AND CONDITIONS
AND BE RESPONSIBLE FOR TI1E SAME.
TIIESE DESI NS, CONCEPTS AND
SPECIFICATIONS ARE INSTRUMENTS OF
SERVICE AND AS SUC11 REMAIN TI1E
EXCLUSIVE PROPERIY OF COUNTRY LUMBER
AND ARE NOT TO BE COPIED WITIIOUT TI1E
WRITTEN CONSENT OF COUNTRY LUMBER.
MAINTENANCE FREE
SIDIN TRiM
p {
l_ j., :; ,
ss
Dwfi"S
4= I'-0
W
rr, L _
n a.,,: a u,.;
AQpRCi lCi7 L GOPY
REVIEW@q Ffiri COOE ONiALIAfdCc
SUBIECTT!,FtE!.GlNS fCT40i a
atc: " y_ __ _.__._ __ ._. '
oTUYP_:
m m
m
o
o
a-
d-
6'
o
Z N
U
0
1w
IAI
r'
Z
o
N N
V N O
4J MN
0Q •'
o
O
a
0
N
N
OF 5
i:s7:,:.. .. _
D/'l(1G \/GAITG AG DG llf1
IVI/ \IIV I LIV/ \IVI../L 1 1\LL
SIDING TRIM
REAR ELEVATION
I/8"= I'-0"
IVIr\IIVILIVrIIVIiL I I\LL
SIDIN Tf IM
LEFT ELEVATION
I/8" = I '-0"
12 12
SiuiNv i KiM
RIGhT ELEVATION
I /8" = I '-0"
I`keil)YI cVLsa Flfl3 ,...--
lP6 R t Ep FIIE COPY
a REVIEV ED POR CODE COMPLIANCE
Ij c ,U IF ',.. Iz_' i,S'=5PECTION
a Date:
igr":aii,rc. .,. Y JhMr i _
N
O
0
N
N
N
d-
N
N
54'_0"
4'-0" 28'-0" 22'-0"
110LD FOUNDATION IN 2"
7_ 4_p FOR EXTERIOR INSUL _ 5_g g_3
6068 SLIDING CSMT. 2636 W/
SLDR_5036 ______ PATIODR_______ EGRESSWELL_
8'-0"
SLDR. 5036 W/
EGRESS WELL
c
c
54'-0"
I
NOTES:
I ) 11EADERS AT EXTERIOR
DOORS WINDOWS TO
BE SIZED BY SUPPLIER
2) SMOKE DET CTORS AS 'I
REQ'D PER CODE '
3) SLIDING WINDOWS
UNIT SIZES INDICATED IN
INCIIES)- VERIFY WINDOW
MANUF. W/ BUILDER
4) FRAMER TO ROCK COMMON
WALLS I N GARAGE
5) ALL INTERIOR WALL 24" O.C.
EXCEPT IN KITCIIEN
SUPPORTING CABINETS
6) KITCIIEN WALL SUPPORTING
CABINETS @ I 6" O.C.
N
SFT. (GARAGE) I /4"= I '-0"
t - - , ' . . .
ENGINEERED ROOF i RUSSES
W/ ENERGY 11EEL @ 2'-0" O.C.
I /2" WAFER BD. 511T.
I 5# FELT
ICE WATER Si11ELD
ASPf1ALT S111NGLES
2x6 SUBFASCIA
ALUM. SOFFIT FASCIA
CONT. SOFFIT VENT
RIGID WIND WAS11 BARRIER
AI R Cf1 UTE
2x6 @ I 6" O.C.
R-21 FIBER L. INSUL.
VAPOR BARRIER
7/ I 6" 05B StiT. OR
3/4" FIBER BD. S11TG.
I /2" 6YP. BD WALLS
MAINT. FREE SIDING
I 2 CRS. I 2" CONC. BLK.
20" x 8" CONC. FTG.
RI ID INSUL. R Q r#
VAPOR BF RR!ERS
WATERPROOFING
G
J
PROVIDE 24" x 36" AREA FOR , x
FUTURE FAN FOR RADON `
SYSTFM ;°
5/8" GYP BD. CLG.
VAPOR BARRIER
R-49 INSUL.
2x I 0 FLR. JSTS
@ I 6" O.C.
3/4" T WAFER
GLUED SCR WED
SPR' FOAM RIM
II
II
II
II N
II
ii
CONC. FLR. SLAB -
n
SEAL ALL LOOR
PENETRATI NS
SUMP BASKET W/ 6 MIL POLY TAPED 4" OF GRAVEL
SEALED LID. 3" VENT @( I 2" MIN. LAP)
PIPE TO VENT OUT ROOF AND SEALED
I 8" FLR TRUSSES
@ I 9.2" O.C.
3/4" T G WAFER
GLUED SCREWED
5/8" GYP. BD.
4" CONC. FLR. SLAB
I CRS. 6" CURB. BLK.
7 CRS. I 2" CONC. BLK.
20" x 8" CONC. FTG.
RIGID INSUL. C 8
VAPOR BARRIERS
WATERPROOFING
C
BUILDING SECTION
SEE BUILDERS SPECIFICATION FOR BUILDING MATERIALS
STAIR INFORMATION
3-2x I 2 STRINGERS
7 3/4" MAX. RISERS
I 0" MIN. TREADS
6'_8" MIN. NEAD
CLEARANCE.
11ANDRAIL TO BE
34" TO 38" NIG11
ENDS ARE TO BE
RETURNED.
ROOF VENTILATION
RATIO I SF. IN 200 SF.
50 % ROOF
50 % SOFFIT
NOTE:
CAULK FLAS11
AROUND ALL EXTERIOR
OPENINGS
2x6 TREATED SILL PLATE
I /2" ANCIIOR BOLT
@ 6'-0" O.C.
SILL SEALER
ouo
a' t,di i Y I:.l_".l:' .
eu:lowa 9afei°
t tP C1df FILE PY
m REVI Vv"c['. rGR 6 JE COMPLIANCE
n SUB1er7 T': lEIC II SPCCTIGiV
I
E _ . . _.. J
3/8" = I '-0"