Loading...
2022-00183CITY OF MONTICELLO 505 WALNUT STREET MONTICELLO, MN 55362- 763) 295-3060 FAX: (763) 295-4404 ADDRESS 4155 87TH ST NE PIN 155252001050 LEGAL DESC FEATHERSTONE 4TH ADDN LOT 001 BLOCK 005 PERMIT TYPE BUILDING PROPERTY TYPE SINGLE FAMILY -DETACHED CONSTRUCTION TYPE BASEMENT FINISH VALUATION $ 25,664.00 NOTE: BASEMENT FINISH: 1 BEDROOM, 1 OFFICE, I BATHROOM, I FAMILY ROOM. APPLICANT WEESE CONSTRUCTION P.O. BOX 71 BUFFALO, MN 55313- 612) 708-8861 OWNER r SALDANA, LIDIA 4155 87TH STREET NE MONTICELLO, MN 55362- AGREEMENT AND SWORN STATEMENT I agree that the work will be conducted in conformance with the ordinances of the City of Monticello and with the Minnesota State Building Code. I understand that the work will be in accordance with the plan that has been approved by the Building Official. I agree that any damage caused to public property including but not limited to curb, sidewalk, public utilities and signs will be repaired at my expense. Applicant Date 7 - //,, a -3-- Bldg Official Date 2 0 2 2- 0 0 1 B 3 DATE ISSUED: 04/11/2022 Permit #: 2022-00183 BUILDING PERMIT FEE PLAN REVIEW STATE SURCHARGE, BLDG VAL TOTAL Payment(s) CHECK 1708 425.44 276.54 12.83 714.81 714.81 SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. CITY OF Monticello BUILDING SAFETY SITE ADDRESS D ECEUVIE - MAR 3 0 2022 ) J Permit No., 7 1 Date RESIDISN44AI6 W41601N&ft IIT ADDITION / ALTERATION / REMODEL I?/ TT 8 7?'sr L., ps .. LEGAL DESCRIPTION LOT 1!91 BLOCK / PI.D. NUMBER / 6C" S,La m / o S' D PLAT 7A Q- OWNER ( Name) (Address) (Tel. No.) 4- A CONTRACTOR ( Name) (Address) (Tel. No.) 49a ; V4 aCAvg /u l,a `iL7a,-rrk6/ CONTRACTOR' S LICENSE NUMBER (IF APPLICABLE) moo s Q a/ PLUMBING BEING COMPLETED BY (PLEASE CHECK ONE): HOMEOWNER CONTRACTOR IF APPLICABLE, SPECIFY CONTRACTOR e„t M, IO Lic # Pm v s' 9 % P,7 CHECK ALL THAT APPLY: TOILET 4e SINK BAR SINK BATHTUB/SHOWER LAUNDRY TUB SOFTENER OTHER TOTAL # OF FIXTURES 3 REMINDER: IF YOU DO NOT OWN THIS PROPERTY OR ARE NOT PERFORMING THE WORK, PERMIT MUST BE PULLED BYA MASTER PLUMBER) MECHANICAL BEING COMPLETED BY (PLEASE CHECK ONE): HOMEOWNER CONTRACTOR IF APPLICABLE, SPECIFY CONTRACTOR CHECK ALL THAT APPLY: FURNACE A/C FIREPLACE _ BATHFAN TOTAL # OF FIXTURES Bond # M 6 op 3''/ "—" 4 DESCRIPTION OF WORK:44 , Z' Ley 1 Jku e ESIfIMATED VALUE OF CONSTRUCTION I Y6 / J z ApprovedbyBuildingOfficial: t---) Date Approved: L% - ' 2-0L,Z Applicant Signature Date 505 Walnut Street, Suite #1 Monticello, MN 55362 Phone: 763-295-3060 Fax: 763-295-4404/ yo Carbon are requ- xi -din 212rms 7ed0'from bedrooms per MS .50 Smoke D Aectors: Hard Wire with batter backup: Locate in each sleeping room, corridor sleeping room access, on each story, in b sement, And where veiling height varies 24" +, Exit QFM- For *aping Ares= Window Char Opening 5.7 k PL Idiii.20' Wide 24' I igh, SIR not more than 4C AM Finished Floor. 0 a 0 3 0 a mIn 0 0 Nr 3 vm 0 g IA m 0z 0 Cj z a e 0 N 0 LD Zz 0 a Y t S E Z t: 00 d Egress Window Wells: Provide 9 sq. ft. Clear openings for egrest window wells. Min. well dimension 3r. Max. depth 48". Fixed ladder required for more than 44' well depth. asal All PenOL-ationa Around Duct, Pipe and Wire Through All Top and Bottocn Plates Insulate walls & Ceilings with sead vapor retarder per Energy Code. p'll Bottom Wall Plates in Contact with Concrete or Masonry Shall Be Decay Resist" NOTE5: 1) HEADER5 AT EXTERIOR DOOR5 t WINDOW5 TO BE 51ZED BY 5UPPUER 2) SMOKE DETECTOR5 A5 REO'D PER CODE 3) 5TEP FTG5 t FDN5 A5 REM FOR GRADE - VERIFY W/ BUILDER 4) 1 CR5. 4' CURB BLK. 16' x 8' CONC. FTG. 2x4 @ I G' O.C. FULL WALL BASEMENT PLAN b N 1/4'= I'-0' 1 II'-IO' III -I, 1 1 RCANT. FL ; ` 'q TRU55E5 2'-0' 7` iNT % "7 HOLD FOUNDATION Br OR S97— 6_ SLDR 5036 SLDR 5020 2' FOR EXTERIOR INSUL. — — 1 -. 2-2x10 2-2x1p LNon2-2xlp .......,.,,. ................. 5 CR5. 8'CONC. BK I 20' x 8 CONC. FTG. w 19 y j2x6@IG' O.C. ?Ln NfF"I Lf KNEE WALL o N N O 02 _ J I b IBA5EMENTI \ l _ 12 CR5. 12' CONC. BLK. N 4' CONC. FLR. 5LAB Z Z z I 20' x 8' CONC. FTG. N o a h \ 22'-0' 5'-5' Q G'-5" 3'-G' 9'-I I' A Da/V1,p'-9' oJ a7iG # 2-2x5' 12 CRS. 12'CONC. BIKz20' x 6' CONC. FTG.— " p so N 2-2X10 — oN In JGOWO'1 I_ I Z? l\,IT Nam,(. : r ELEVATOR J I - I N I ui FUTURE —J C, I I l -----—_3 9 I/2' MLH - LID X xG WOOD P05T \ l Ln L JL = _ I ON30'x30'x 12' I 1 > > ` l » I CR5G' CURB BLK \Wk \J DEEP CONC FTG. \ 2 CR5'. G' CONC. BLK. 4 — — — — — 12 CR5. 12' CONC. BLK. l 4 I CR5. G.'CUP5 . 2 CR5. 6' COBLK. § I 20' x 8' CONC. FTG. ~ 12 CR5. 12' CONC. BLK.1\\\\\\' ;I• Z: Z: \A t.MA\ l 20' x 8' CONC. FTG. i`— „ . ° / \\\\ ...— — NN N L Clod oioal Fan Ventilation ReWred: . I 4 I — — — lHOLDFOUNDATIONINBathFan Shall Be Vented and l , 2' FOR EXTERIOR IN5UL. l I Insulated to Building Exterior l r J NI CR5. G' CONC. BLK. l I Under SUIT; N I4 CR5. 8' CONC. BLK. I Comer *,h 1/2 inch GYPsurn B 16' x8' CONC. FTG. )UNEXCAVATED I, I Oars II 4 FIREBLOCVJNGREQUIRED: Cut Off Concealed Draft Openings l Between stories & Attic, Close 41 Horizontal : o Vertical Penetrations. I \I I 14 l I CR5. O 6' CONC. BLKC. . l l20' x 8 CONCN FTG. I L4----------___---- JAI 10 1% 2' 6-3• — — I'-9' — — — 16'-3' V-10 1%2' J 4'- 9 Y 39- 0' 8'-0' ry 16'- 0' 58'-(Y AA:@OAR APPROVED FILE COPY EVIEWED FOR CODE COMPLIANCE UBIECTTOFIELD INSPECTION Date:- Signatu-: K 3 OF 5 M