Loading...
Planning Commission Agenda 06-07-2016 AGENDA REGULAR MEETING - MONTICELLO PLA NNING COMMISSION Tue sday, June 7th , 201 6 - 6:0 0 p.m. Mississippi Room , Monticello Community Center SPECIAL JOINT CITY COUNCIL & PLANNING COMMISSION WORKSHOP 5:00 PM Mississippi Room, Monticello Community Center Monticello High School Concept Stage PUD Submittal C ommissioners: Brad Fyle , Linda Buchmann, Sam Murdoff , John Falenschek, Marc Simpson Council Liaison: Charlotte Gabler Staff : Angela Schumann, Steve Grittman ( NAC ) , John Rued 1. General Business A. Call to O rder B. Consideration of approving m inutes th a. Special Meeting Minutes April 5 , 2016 th b. Regular Meeting Minutes April 5 , 2016 rd c. Regular Meeting Minutes May 3 , 2016 C. Citizen Comments D. C onsideration of adding items to the agenda 2. Public Hearings A. Public Hearing Consideration of a request for P reliminary and F inal P lat for Clear Creek Addition, a request for C onditional U se P ermit for building C onditional U se P ermit for cross parking and access, a r equest for V ariance to required yard setbacks, and a request for O rdinance A mendment to allow bulk fuel s torage/sales in an I - 1 (Light Industrial) D istrict as a permitted or conditional use, including a Conditional Use Permit as required . Applicant: Clear Creek Land Company, LLC B. Public Hearing Consideration of a request for P reliminary and F inal P lat for Monticello High School , a request for rezoning to Planned Unit Development including Development and Final Stage Planned Unit Development, and a request for amendment to Conditional Use Permit for K - 12 Education Use for Monticello High School Applicant: Wold Architects & Engineers 3. Regular Agenda A. Consideration of the Community Development Directors R eport 4. Added Items 5. Adjournment MINU TES JOINT PLANNING COMMISSION/CITY COUNCIL WORKSHOP MISSISSIPPI ROOM, MONTICELLO COMMUNITY CENTER 4:30 PM, TUESDAY, APRIL 5, 2016 Commissioners : Brad Fyle, Linda Buchmann, John Falen schek, Marc Simpson Council Members: Mayor Brian Stumpf, Charlotte Gabler, Lloyd Hil gart, Tom Perrault Absent: Mayor Brian Stumpf, Sam Murdoff, Glen Posusta Staff: Angela Schumann, Steve Grittman (NAC), John Rued Others: Pat Sawatzke 1. Call to Order . Chair Brad Fyle called the special meeting to order at 4:30 p.m. 2. Consideration to review Monticello Zoning Ordinance, Chapter 4, Section 5 - Signs . Angela Schumann indicated that the purpose of the meeting is to review the Monticello Zoning Ordinance as it relates to signs in Chapter 4, Section 5. When the City Council approved the Temporary Sign Ordinance, the motion made by Councilmember Gabler was to allow the ordinance to go forward if and such that the Planning Commission and City Council hold a joint workshop to review temporary signs and per manent signs as a whole. Schumann reviewed a presentation with the group defining signs, types of signs, where signs can be placed on a property for a single user, non - freeway bonus, and a multi - tenant, non - freeway bonus. Also reviewed what are conside red temporary signs, the Temporary Sign Ordinance, community event signage and speech, and non - commercial signage. Schumann stated that staff is recommending a proposed amendment to the ordinance for non - commercial speech signage, which would address the community event signage . The changes include the amount of days a sign can be placed before an event, and regulations for placing signage on vacant property. The group was in consensus with the staff recommended changes to the ordinance as presented by Community Development Director Schumann. 3. Adjournment. LINDA BUCHMANN MOVED TO ADJOURN THE MEETING AT 5:41 P.M. MOTION SECONDED BY JOHN F A L E N SCHEK. MOTION CARRIED UNANIMOUSLY. RECORDED BY: __________________________________ _____ _ DATE APPROVED: __________________________________ _____ _ ATTEST: __________________________________________ _____ __ Angela Schumann, Community Development Director MINUTES REGULAR MEETING - MONTICELLO PLANNING COMMISSION th Tuesday , April 5 , 2016 - 6:00 p.m. Mississippi Room, Monticello Community Center Present: Brad Fyle, Linda Buchmann, John Falenschek , Marc Simpson Absent: Sam Murdoff Others: Angela Schumann, Steve Grittman (NAC) , John Rued, Charlotte Gabler (Council Liaison) , Barry Fluth, Brad Hiltz, Lisa Hiltz , Shawn Grady 1. General Business A. Call to Order Brad Fyle called the meeting to order at 6 p.m. B. Consideration of a pprov ing minutes ND LINDA BUCHMANN MOVED TO APPROVE THE MARCH 2 , 2016 SPECIAL MEETING MINUTES. JOHN FALENSCHEK SECONDED THE MOTION. MOTION CARRIED 4 - 0. ND MARC SIMPSON MOVED TO APPROVE THE MARCH 2 , 2016 REGULAR MEETING MINUTES. LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED 4 - 0. C. Citizen Comments None D. Consideration of adding items to the agenda None 2 Public Hearings . A. Continued Public Hearing - Consideration of a request for amendment to the Official Zoning Map for rezoning to CCD Residential Overlay District (CCD - R) to accommodate multiple family attached housin g, including residential uses on the ground floor as per Chapter 3.7(J) Overlay Zoning Districts of the Zoning Code. Applicant: Masters Fifth Avenue, Inc. (NAC) , Planning Case Number: 2016 - 008 Steve Grittman recommended that the Planning Commission delay review of the request to rezon e rd pro perty at Locust an d 3 Street to CCD - R pending consideration of rezoning t o PUD to accommodate the d ensity requirement s of the proposed residential development . Decision 1: Rezoning to add the CCD Residential Overlay District to the subject property LINDA BUCHMANN MO VED TO TABLE ACTION AND CONTINUE THE PUB LIC HEARING ON THE REZONING, PEN DING ADDITIONAL INFO RMATION. MARC SIMPSON SECONDED THE MOTION. MOTION CARRIED 4 - 0. B. Public Hearing - Consideration of a request for Conditional Use Permit (CUP) to accommodate multiple family attached housing, including residential uses on the ground Planning Commission Minutes: 4 /0 5 /16 floor in a proposed Central Community Distric t - Residential (CCD - R) District. Applicant: Masters Fifth Avenue, Inc . (NAC) P lanning Case Number: 2016 - 008 Steve Grittman recommended that the Planning Commission also d elay review of the CUP associated with rezoning to CCD - R pending a decision related to rezoning to PUD . Decision 1 : Conditional Use Permit (CUP) to accommodate multiple family attached housing, including residential uses on the ground floor in a proposed Central Community District - Residential (CCD - R) District LINDA BUCHMANN MOVED TO TABLE ACTION AND CONTINUE THE PUB LIC HEARING ON THE CONDITIONAL U SE PERMIT, PENDING A DDITIONAL INFORMATION. MARC SIMPSON SECONDED THE MOTION. MOTION CARRIED 4 - 0. C. Public Hearing Consideration of a request for Ordinance Amendmen t for rezoning for Development Stage Planned Unit Development (PUD) for a multiple family attached housing project in the Central Community District (CCD). Applicant: Masters Fifth Avenue , (NAC) Planning Case File: 2016 - 015 Steve Grittman explained th at the applicant had opted to request rezon ing to PUD to allow for flexing development standards to accommodate the use and density requirements of the rd housing project proposed for property at Locust and 3 Street . Grittman asked the commissioners to consider to how the proposed project fits the site in terms of allowing residential use on the ground floor , the intensity of the use , and th e d esign within the context of the goals of the Embracing Downtown Monticello Plan . Grittman noted that many of the preliminary site plan and architectural issues discussed during c oncept r eview had been incorporated into the Development Stage PUD . He ou tlined site plan considerations and highlighted conce rns r elated to scale , garage layout an d building design theme . He pointed out that staff had proposed that covered parking be incorporated into the building design as an alternative option. Grittman noted conditions of approval included in Exhibit Z . Brad Fyle opened the public hearing. Developer Barry Fluth of Masters Fifth Avenue introduce d Brad and Lisa Hiltz and pointed out that they would be purchasing and developing the property. Lisa Hiltz pointed out that the project is d esignated an independent living facility for ages 55 and older . Hiltz responded to questions about project design and rental options . She explained that includ ing underground or at ground level parking would de crease the number of covered parking spaces and increase the project cost by 25% . Shawn Grady , owner of Ace Hardware, was invited to speak. He acknowledged that adding residential housing w ould benefit his business but pointed out that allowing residential units on the ground floor limits the opportunity for commercial activity. He also noted an ongoing parking con cern. 2 Planning Commission Minutes: 4 /0 5 /16 As there were no further comments, the public hearing was closed. Decision 1: Consideration of a Rezoning from CCD, F - 1, to Planned Unit Development (PUD) District and Development Stage PUD to accommodate the c onstruction of a 23 unit multiple family residential building and associated site improvements, parking and garage buildings. JOHN FALENSCHEK MOVE D TO ADOPT RESOLUTION NO. 2016 - 006 RECOMMENDING APPROVA L OF REZONING FROM CCD, F - 1, TO PUD DISTRICT, AND DEVELOPMENT STAG E PUD BASED ON THE F INDINGS IN SAID RESOLUTION, AND CONT INGENT ON COMPLIANCE WITH THE CONDITIONS LISTED IN EXHIBIT Z. LINDA BUCHMANN SECON DED THE MOTION. MOTI ON CARRIED 4 - 0. EXHIBIT Z Rezoning to Planned Unit Development and PUD Development Stage Site Plan Review Lots 1 - 3, Block 36, Original Monticello Plat Conditions of Approval 1. Redesign of the detached garage buildings to provide the following: a. Flat - roofed design b. Variable roof heights c. Materials reflective of those on the princ ipal building d. Variable wall facades facing adjoining properties 2. Redesign of building entrance points to incorporate flat - roofed design. 3. Deck materials shall be consistent with Embracing Downtown Guidelines. rd 4. Provision of on - street parking along 3 Street as noted on approved site plan. rd 5. Add tree planting to sidewalk along 3 Street similar to proposed planting on Locust Street. rd 6. Extend sidewalk from project to Walnut Street along 3 Street. 7. Extend sidewalk along Locust Street to meet existing si dewalk to north. 8. Utilize sidewalk materials consistent with Walnut Streetscape improvements. 9. aluminum. 10. Revise trash enclosure to provide a visual barrier at the access point f rom the parking lot. 3 Planning Commission Minutes: 4 /0 5 /16 11. Provide lighting plans that meet the zoning ordinance requirements, and utilize materials and elements consistent with Walnut Streetscape. 12. Reduce wall sign size to 32 square feet, consistent with ordinance allowances. 13. Provide a curre nt topographic survey and prepare grading, drainage, and utility plans consistent with the requirements and comments from the City Engineer in the 14. Other comments of the Planning Commission and Staff provided at th e Public Hearing. D. Public Hearing Consideration of a request for an Amendment to Conditional Use Permit (CUP) for Development Stage Planned Unit Development (PUD) for a single lot development in the B - 4 (Regional Business) District. Applicant: Retail Partners Monticello, LLC (NAC) Plann ing Case Number: 2016 - 013 Steve Grittman explained that the applicant had requested an amend ment to the C UP for P UD to construct a d ental office on vacant property located at 9281 Cedar Street and to allow the parking lot to connect to lots north and so u th of the development site. Grittman provided an overview of the proposed site plan and outlined the analysis involved in considering the CUP request. He pointed out that the proposed plan facili tates common access, provides ample parking , and includes additional greenspace . Grittman reviewed staff comments related to the location of the trash enclosure, the design of the light poles and fixtures and style of pylon signage proposed and poi nted out that these issues must be addressed as conditions of approval noted in Exhibit Z. Brad Fyle opened the public hearing. Clark Lohr of Louks, Inc. spoke on behalf o f Retail Partners , LLC. He pointed out that the site plan had been revised to address staff comments . He explained that the trash enclosure had been redesigned to attach to the rear of the structure , but noted that four parking stalls would be eliminated as a result of the re design. Lohr proof of parking for th e stalls originally proposed and asked that the applicant be given the o pportunity to construct th e stalls should the parking demand exist. Hearing no further comments, the public hearing was closed. LINDA BUCHMANN MO VED TO ADOPT RESOLUTION NO. PC - 2016 - 007, APPROVING THE AMENDM ENT TO THE CONDITION AL USE PERMIT PUD, B ASED ON FINDINGS IN THE R ESOLUTION, AND INCORPORATING THE CO NDITIONS IN EXHIBIT Z. JOHN FALENSCHEK SECONDED THE MOTION. MOTION CARRIED 4 - 0. 4 Planning Commission Minutes: 4 /0 5 /16 EXHIBIT Z Amendment to Conditional Use Permit Planned Unit Development (Development Stage) Lot 1, Block 1, Jerry Hartung Addition , 9281 Cedar Street 1. The trash handling equipment shall be relocated to an area attached to, or within, the principal building, or in a reasonable location that is not in a yard adjoining a public street. 2. The parking lot light fixtures shall match the existing PUD in style and he ight. 3. Wrap the proposed freestanding sign pole to match the style of other freestanding signs in the PUD. 4. Applicant shall provide documentation of the easement and maintenance agreement for cross access and parking with the properties to the north and so uth. 5. Compliance with the requirements and comments of the City Engineer in the review letter dated March 30, 2016. 3 . Regular Agenda A. Consideration to review land use and zoning for 1547 East Broadway The commissioners took no action in response to information related to land use and zoning designation s for 1547 East Broadway and allowable uses within the Limited Business (B - 2) District that staff had provided for reference. B . th Planning Commission Recommendations On March 25 , t he City Council approved a Conditional Use Permit for c o - location of a w ireless t elecommunication s ervice a ntenna on a City w ater tower and the c orresponding lease agreement for the antenna. 4 . Added Items N one 5. Adjourn LINDA BUCHMANN MOVED TO ADJOURN THE MEETING AT 7: 34 PM. MARC SIMPSON SECONDED THE MOTION. MOTION CARRIED 4 - 0. R ecorder: Kerry Burri __ Approved: Attest: ____________________________________________ Angela Schumann, Community Development Director 5 MINUTES REGULAR MEETING - MONTICELLO PLA NNING COMMISSION Tue sday, May 3rd , 201 6 - 6:0 0 p.m. Mississippi Room , Monticello Community Center C ommissioners: Brad Fyle , Linda Buchmann, Sam Murdoff , John Falenschek, Marc Simpson Council Liaison: Charlotte Gabler Staff: Angela Schumann, Steve Grittman ( NAC ) , John Rued 1. General Business A. Call to O rder Chairman Fyle called the meeting to order at 6:00 p.m. B. Consideration of approving m inutes th a. Special Meeting Minutes April 5 , 2016 (to be provided) th b. Regular Meeting Minutes April 5 , 2016 (to be provided) Angela Schumann reported that the minutes would be provided with the June agenda. C. Citizen Comments NONE. D. Consideration of adding items to the agenda NONE. 2. Public Hearings Continued Pub lic Hearing Consideration of a request for amendment to the A. Official Zoning Map for rezoning to CCD Residential Overlay District (CCD - R) to accommodate multiple family attached housing, including residential uses on the ground floor as per Chapter 3.7(J) Overlay Zoning District s of the Monticello Zoning Code. Applicant: Masters Fifth Avenue, Inc. Planning Case Number: 2016 - 008 th Angela Schumann reported that the applicant , Masters 5 Avenue, had provided a le tter requesting that the Planni n g C ommission table a ction on both the CCD - R overlay and the conditional use permit request related to the proposed project . At this time the applicant is seeking a p lanned unti l development for the proposed project via a separate application and review process . The Planning Commission has previously recommended approval of the development stage PUD, which was subsequently approved by the City Council. The applicant will need to move forward to final stage to complete the PUD. If for any reason the PUD does not move forward, the applicant 1 indic a ted that i t is their intent to bring the CCD - R rezoning and CUP items back for consideration . SAM MURDOFF MOVED TO TABLE ACT ION ON THE REQUEST AND TO CONTINUE THE HEARING ON THE REZONING AT THE REQUEST OF THE APPLICANT. MOTION SECONDED BY LINDA BUCHMANN. MOTION CARRIED, 5 - 0. Continued Publi c Hearing Consideration of a request for Conditional Use B. Permit (CUP) to accommodate multiple family attached housing, including residential uses on the ground floor in a proposed Central Community District - Residential (CCD - R) District . Applicant: Masters Fifth Avenue, Inc. Plann ing Case Number : 2016 - 008 LINDA BUCHMANN MOVED TO TABLE ACTION ON THE REQUEST AND TO CONTINUE THE HEARING ON THE REZONING AT THE REQUEST OF THE APPLICANT. MOTION SECONDED BY JOHN FALENSCHEK. MOTION CARRIED, 5 - 0. Public Hearing Consideration of a requ est for Amendment to the C. Monticello Zoning Ordinance to allow Entertainment/Recreation, Indoor Commercial use in the B - 3 (Highway Business) District; and a request for Conditional Use Permit (CUP) related to Entertainment/Recreation, Indoor Commercial use in the B - 3 (Highway Business) District. Applicant: Next Level Baseball and Softball Training, Inc. Planning Case Number: 2016 - 019 NAC Planner Nate Sparks reviewed the staff report for the request. Mr. Sparks stated that the applicant has submitted a request to add language to the zoning ordinance allowing Entertainment/Recreation, Indoor Commercial as an allowable use in the B - 3 zoning district. This would allow them to utilize a portion of the building at 3939 Chelsea Road for an indoor baseball fac ility . Entertainment/Recreation, Indoor Commercial is curre ntly permitted in the B - 4, Regional Business District . Outdoor commercial uses are currently conditional uses in both the B - 3 and B - 4 districts . As such, this use would be allowable in the B - 3 i f it were to be located outside. Sparks indicated the Planning Commission has the option to amend the language to allow this use as either a permitted or conditional use. Mr. Sparks noted the proposed conditions for such use. He stated staff is recomm ending approval of the proposed amendment, subject to review of those conditions. It was noted that a similar text amendment had been proposed and approved for the IBC Industrial and Business Campus District. The Commission discussed whether the use s hould be allowed as conditional or permitted use, including the other potential uses in the category and the application requirements for CUP. 2 Chairman Fyle opened the public hearing. Lloyd Peterson, President of Baseball Operations for Next Level, addresses the Commission. He explained that the use on this site is completely indoors. The site will accommodate both baseball and softball training. At any one time there will be 15 - 20 persons in training. These will be scheduled training appointment s and team - based. Wayne Elam, Commercial Realty Solutions, addressed the Commission. He noted that staff and the applicant have brought the item forward as a permitted use, aligning it with the B - 4 zoning district for consist ency. Both uses are commerci al in nature. Chairman Fyle closed the public hearing as there were no other comments from the public . LINDA BUCHMAN MOTION ED TO ADOPT RESOLUTION NO. PC - 2016 - 008, RECOMMENDING APPROVAL OF THE AMENDMENT TO THE ZONING ORDINANCE ADDING ENTERTAINMENT/RECREATION, INDOOR COMMERCIAL AS A PERMITTED USE IN THE B - 3 DISTRICT, AMENDING THE USE TABLE (TABLE 5 - 1) TO INDICATE THE CHANGE. THE MOTION INCLUDES ADOPTI ON OF THE FINDINGS IN THE RESOLUTION, AND OTHERS AS IDENTIFIED AT THE HEARING. MOTION SECONDED BY JOHN FALENSCHEK. Commissioner Murdoff inquired whether Exhibit Z would apply if the amendment allows the use as permitted . Angela Schuman confirmed that the Exhibit Z conditions are included in the base code. As such, those items will carry forward in a review of any such use, whether it is conditional or permitted. Nate Sparks confirmed that the Planning Commission is also requested to move a recommen dation forward on the conditional use permit portion of the s request. In the event that City Council elects to approve the amendment to allow Entertainment/Recreation, Indoor Commercial as a conditional use, rather than permitted, the Planning recommendation on the CUP portion of the application is needed. MOTION CARRIED, 5 - 0. SAM MURDOFF MOTION ED TO ADOPT RESOLUTION NO. PC - 2016 - 009, RECOMMENDING APPROVAL OF A CONDITIONAL USE PERMIT FOR A SPORTS TRAINING FACILITY IN THE B - 3, HIGHWAY BUSINESS DISTRICT, SUBJECT TO THE REQUIREMENTS OF THE ZONING ORDINANCE APPLICABLE TO ENTERTAINMENT/RECREATION AS LIST ED IN EXHIBIT Z , INDOOR 3 COMMERCIAL USES. MOTION SECONDED BY LINDA BUCHMANN. MOTION CARRIED, 5 - 0. EXHIBIT Z Conditions of Approval Lot 1, Block 1, Gould Addition Next Level Baseball 1. Compliance with the terms of the zoning ordinance related to Entertain ment/Recreation, Indoor Commercial uses, specifically: (a) No auctions shall take place on the premises. (b) Outdoor storage shall be prohibited. (c) Noise shall be controlled consistent with the standards of this ordinance. (d) When abutting a residential use, the property shall be screened with an aesthetic buffer (Table 4 - section4.1(G) of this ordinance Public Hearing Consideration of a request for Preliminary and Final Plat D. for Monticello Middle School; Conditional Use Permit for Schools, K - 12 use; and Amendment to the Official Monticello Zoning Map for Rezoning from Agricultural Open Space (A - O) District to Single - Family Residence (R - 1) District. Applicant: Wold Architects & Engineers . Planning Case N umber: 2016 - 020 Nat Sparks provided the staff review of the item. He stated that the applicant is proposing a 4,775 square foot addition to the front of the existing school building. Future phases of additional work would be proposed separately. Curren tly, the site is zoned A - O. School are allowed in R - 1 districts as conditional uses. Given the proposed changes, it is recommended that the school be rezoned to R - 1, with a conditional use for the proposed site changes. Mr. Sparks indicated that the pro posed additional meets code requirements. He noted that it is not uncommon to find schools listed as a conditional use permit in residential districts, given that they are often in close proximity to residential areas. The conditions in the code for such uses are written in a way to limit the locations of schools in these areas. In addition, the applicant is proposing a preliminary and final plat, which assembles the various parcels and vacated right of way. Sparks outlined the conditions in Exhibit Z. Mr. Sparks confirmed that the Comprehensive Plan does indicate that the use Comprehensive Plan. Angela Schumann noted that zoning of the school has historically been A - O. A t present, the school is an existing lawful non - 4 conforming use in the A - O. However, as the school moves forward with any expansions or site plan changes, these trigger additional review and it is important that the school exist within a district that allo ws for them to propose such modifications under a zoning district which allows the school as a use and a conditional use permit application. in the re - codification of the zoning ordinance, the Public/Semi - Public zoning dist rict was eliminated and those zo ned PS were rezoned to R - 1 districts. As such, the rezoning of the Middle School to R - 1 is consistent with other schools in the community. Ms. Schumann also noted that need to plat to consolidate the various parcels and various right of way to place the s chool facility on one parcel. Commission Gabler inquired whether the Moose Sherritt Area would be impacted. Angela Schumann stated that the facility is not impacted by these actions. Chairman Fyle opened the public hearing. Eric Linnear, Wold Architect s , confirmed that in reviewing the project with the City, it was recommended that a plat be brought forward to address the various parcels involved; in addition, bringing the site into conformance with zoning designation. Those are the primary areas of fo cus for the application. Other projects on this site are anticipated next year and Linnear stated that it is understood an amendment to the CUP will be required at that time. Hearing no further comment, Chairman Fyle closed the public hearing SAM MURDOFF MOTION ED TO ADOPT RESOLUTION NO. PC - 2016 - 010, RECOMMENDING ADOPTION OF AN ORDINANCE REZONING THE PROPERTY FROM A - O, AGRICULTURE OPEN SPACE TO R - 1, SINGLE FAMILY RESIDENTIAL, BASED ON FINDINGS IN SAID RESOLUTION. MOTION SECONDED BY LINDA BUCHMA NN. MOTION CARRIED, 5 - 0. LINDA BUCHMANN MOTION ED TO ADOPT RESOLUTION NO. PC - 2016 - 011, RECOMMENDING APPROVAL OF A CONDITIONAL USE PERMIT FOR A SCHOOL IN AN R - 1 ZONING DISTRICT, SUBJECT TO APPLICABLE CONDITIONS IDENTIFIED IN EXHIBIT Z . MOTION SECONDED BY MARC SIMPSON. MOTION CARRIED, 5 - 0. EXHIBIT Z Conditional Use Permit for School in R - 1 District 800 Broadway East Monticello Middle School 1. 28th, 2016. 5 2. Comments and recommendations of other staff and Planning Commission. LINDA BUCHMANN MOTION TO ADOPT RESOLUTION NO. PC - 2016 - 012, RECOMMENDING APPROVAL OF A PRELIMINARY PLAT FOR THE MONTICELLO MIDDLE SCHOOL ADDITION, SUBJECT TO THE CONDITIONS IDENTIFIED IN EXHIBIT Z. MOTION SECONDED BY SAM MURDOFF. MOTION CARRIED, 5 - 0. EXHIBIT Z 800 Broadway East Monticello Middle School 1. April 28th, 2016. 2. Comments and recommendations of other staff and Planning Commission. Public Hearing - Consideration of a request for Conditional Use Permit for E. Schools, K - 12 use; and Amendment to the Official Monticello Zoning Map for Rezoning from Agricultural Open Space (A - O) District to Single - Family Residence (R - 1) Di stric t. Applicant: Wold Architects & Engineers . Planning Case Number: 2016 - 021 Nate Sparks provided an overview of the requests, stating that similar to the prior request, the applicant is seeking a rezoning of the Pinewood Elementary School site from A - O t o R - 1 to accommodate the conditional use permit for site changes. The site changes include the reconfiguration of parking lot and drive aisles, as well as the relocation of drive aisles. The changes will support segregation of traffic patterns on the s ite between pedestrians, buses and passenger vehicles. Sparks reviewed the conditions of approval, requiring replacement of landscaping on the east side of the site. With conditions as noted, staff recommends approval of the rezoning and CUP. Commissi oner Buchmann confirmed that there are no expansions to the building itself. Chairman Fyle opened the public hearing. Hearing no comment, Chairman Fyle closed the public hearing. SAM MURDOFF MOTION ED TO ADOPT RESOLUTION NO. PC - 2016 - 013, RECOMMENDING ADOPTION OF AN ORDINANCE REZONING THE PROPERTY FROM A - O, AGRICULTURE OPEN SPACE TO R - 1, 6 SINGLE FAMILY RESIDENTIAL, BASED ON FINDINGS IN SAID RESOLUTION . MOTION SECONDED BY MARC SIMPSON. MOTION CARRIED, 5 - 0. LIND A BUCHMANN MOTION ED TO ADOPT RESOLUTION NO . PC - 2016 - 014, RECOMMENDING APPROVAL OF A CONDITIONAL USE PERMIT FOR A SCHOOL IN AN R - 1 ZONING DISTRICT, SUBJECT TO THE CONDITIONS IDENTIFIED IN EXHIBIT Z. MOTION SECONDED BY JOHN FALENSCHEK. MOTION CARRIED, 5 - 0. EXHIBIT Z Conditional Use Permit for School in R - 1 District 1010 West Broadway Pinewood Elementary School . 1. Supplementary landscaping is provided to replace some of the trees removed due to the parking lot expansion, and to increase the buffering impact from the new parking lot and driveway aisles, where appropriate. 2. 28th, 2016. 3. Comments and recommendations of other staff and Planning Commission. Public Hearing - Consideration of Amendment to the Monticello Zoning F. O rdinance, Chapter 4, Section 5 Signs, as rel ated to community event signage. Applicant: City of Monticello . Planning Case Number: 2016 - 011 Angela Schumann reviewed proposed amendments to the Monticello Zoning Ordinance as related to non - commercial temporary signage. She noted that the discussion had arisen out of discussions related to temporary signs for community events. Schumann referenced the recent ordinance amendment for temporary signs, which limits the use of temporary signs to 120 days per business per calendar year. Community event signage would fall into those regulations as currently written. The proposed ordinance amendment addresses non - commercial speech for such purposes, outside of the regulations relating to commercial speech. In addition, the ordinance addresses regulations relating to content - based speech in the sign ordinance. Schumann referenced the ordinance definitions for commercial speech and non - commercial speech. The proposed amendment would delete the definition for mmunity - type of sign. The ordinance then proposes regulations for non - commercial speech temporary signs within the Temporary Sign provisions in Chapter 4.5 of the 7 zoning code. These sign s cannot be the principal use of property. Total area of such signs is limited to 40 square feet and can be placed for up to 21 days within a 30 - day period. No permit is required. These signs cannot be placed in public right of way or in easements. Sch uman noted that a provision was discussed relating to the ability to use vacant parcels held in common ownership did not carry forward to this proposed amendment. Commissioner Murdoff inquired about the spacing requirement. Angela Schumann noted that duri ng election year, there are specific regulations for that type of signage. However, the spacing requirement in tandem with the total square footage requirement, will be somewhat limiting. Commission Murdoff inquired whether off - premise signs will contin ue to be prohibited. Schumann confirmed that off - premise signs are already listed under code area. Chairman Fyle asked about signage relating to employment for public uses or public events. Schumann noted that the City is trying to get to the point where we are avoiding content - based review and regulation. Some of the signs referenced by the chair would fall into the non - commercial area. Angela Schumann stated that the Ci ty Attorney has reviewed this language in preliminary form and will be asked to review again prior to Council adoption. Chairman Fyle opened the public hearing. Troy Rheaume of Rheaume Signs in St. Cloud addressed the Commission. He encouraged the City to consider allowing digital temporary signs, specifically LED signs, which are now offered by sign businesses. This is a relatively new technology. Chairman Fyle closed the public hearing after hearing no other comments. JOHN FALENSCHEK MOTIONED TO ADOPT RESOLUTION NO. PC - 2016 - 015, RECOMMENDING APPROVAL OF THE AMENDMENT TO THE MONTICELLO ZONING ORDINANCE, CHAPTER 4, SECTION 5, BASED ON FINDINGS IN THE RESOLUTION. MOTION SECONDED BY SUM MURDOFF. MOTION CARRIED, 5 - 0. Public Hearing - Consideration of a re quest for Amendment to the Monticello G. Zoning Ordinance, Chapter 5, Section 4, as related to temporary use permit requirements for special events . Applicant: City of Monticello . Planning Case Number: 2016 - 027 Angela Schumann presented the staff report, stating that through the administration of the special event ordinance, it has been found that review and permitting of these uses requires coordination with multiple City departments and h, staff is recommending removal of the regulations from the Zoning Ordinance with their replacement in City Code, where they would be issued 8 There would also be some minor modifications to the language relating to when permits require use of City resources or property. Chairman Fyle opened the public hearing. Hearing no comment, Chairman Fyle closed the public hearing. LINDA BUCHMANN MOTIONED TO RECOMMEND ADOPTION OF ORDINANCE NO. 641, RECOMMENDING APPROVAL OF THE AMENDMENT TO THE MONTICELLO ZONING ORDINANCE, CHAPTER 5, SECTION 4 TEMPORARY USES, BASED ON A FINDING THAT THE PROPOSED AMENDMENT WILL FACILITATE IMPROVEMENT S TO THE PERMITTING OF SPECIAL EVENT USES IN ACCORDANCE WITH OTHER REQUIRED CITY DEPARTMENTS AND LICENSES. MOTION SECONDED BY LINDA BUCHMANN. MOTION CARRIED, 5 - 0. 3. Regular Agenda Consideration to adopt Resolution No. PC - 2016 - 016, a Resolution finding A. that the proposed sale of Certain Land by the City of Monticello Economic Development Authority for Industrial Park Purposes is consistent with the City of Monticello Comprehensive Plan Angela Schumann provided information relating to the decision item. Schum ann stated that the City and EDA are seeking to convey two parcels of property at Otter Creek business park by the City of Monticello Economic Development Authority to an existing business within the park for an expansion project . The Planning Commission is asked to consider whether Schumann stated that t he two parcels are located within an area guided Monticello Comprehensive Plan, which provides locations for the retention, expansion and creation of businesses that provide jobs for Monticello residents and expansion and diversification of the property The proposed conveyance of this property to Clear Creek Land, LLC will facilitate an expansion of their existing beverage distribution business . The proposed expansion, in addition to contributing additional tax base to the community, will support retention of an existing business and employment, as well as the addi tion of employees for the expansion area. Schumann explained that the proposed expansion project will require other land use approvals, including platting of the outlots into lots a nd blocks for development. The requested action at this time relates on ly to conformance with the Comprehensive Plan. Chairman Fyle inquired why the City owns the property versus the EDA. Schumann responded that ownership by the City is for tax purposes. Marc 9 Simpson inquired about the acreage of the parcels. Schumann res ponded that the total acreage is approximately 7 acres total. Council member Gabler inquired about additional industrial land availability. Schumann responded that the EDA and IEDC are looking at that issue. She illustrated existing and future guided ar eas for industrial land uses. SAM MURDOFF MOTIONED TO ADOPT RESOLUTION NO. PC - 2016 - 016, A R ESOLUTION F INDING THAT T HE PROPOSED S ALE O F CERTAIN L AND BY THE CITY OF MONTICELLO ECONOMIC DEVELOPMENT AUTHORITY FOR INDUSTRIAL PARK PURPOSES I S C ONSISTENT WITH TH E CITY OF MONTICELLO COMPREHENSIVE PLAN. MOTION SECONDED BY LINDA BUCHMANN. MOTION CARRIED, 5 - 0. Consideration of review and comment on Monticello Zoning Ordinance, B. Chapter 4, Section 5 - Signs as related to electronic billboards. Angela Schumann address ed the Planning Commission on the item. She asked for the Planning Commission to consider current sign ordinance regulations as they would be applied to a request for an electronic billboard. - premise signs and are prohibited by ordinance. Existing billboards located within the community are considered to be existing lawful non - conforming uses, and are allowed to continue subject to regulations for such uses. The City had received an inquiry relating to the possible conversion of an existing billboard to an electronic billboard. In discussing the potential improvement of a billboard to include electronic messaging, she stated that Community Development staff have determined that such a change would be itself remained unchanged in its physical dimensions. An electronic billboard ing LED illumination) within Chapter 4.5 Signs . Planning staff is bringing this item forward as a point of discussion or possible future action for the Commission. Commissioner Gabler inquired whether MnDOT has regulations for these type of structures. Schumann indicated that she would defer to the Rheaumes representative address that item. She inquired about the lighting and timing of message change. Schumann responded that messages are allowed to change dinance. Commissioner Murdoff inquired as to the purpose of prohibition of off - premise signage, including billboards. Schumann responded that the basic 10 purposes include health, safety and welfare, ensuring that rights of way and boulevards are maintained for visibility and safety of traffic. In addition, it is of those businesses located within the community. Nate Sparks also noted that there is a concern regarding such signag e being a principle use of property versus an accessory use. Troy Rheaumes, Rheaumes Signs of St. Cloud, addressed the Commission. Rheaumes indicated that the state does require a limit of 6 seconds. No transition effects are allowed. He also noted t hat many cities require a dimmer on the lights and a limit on the illumination. A spacing requirement may be a consideration. After discussion, the Planning Commission directed no further action. Schumann noted she would also bring the item to the City Council. Consideration of the Community Development Directors Report C. 4. Added Items NONE. 5. Adjournment LINDA BUCHMAN MOTIONED TO ADJOURN THE MEETING AT 7:45 p.m. MOTION SECONDED BY MARC SIMPSON. MOTION CARRIED, 5 - 0. 11 P lanning Commission Agenda 06 / 0 7 / 201 6 2A . Public Hearing Consideration of a request for Preliminary and Final Plat for Clear Creek Addition, a request for Conditional Use Permit for building height access, a request for Variance to required yard setbacks, and a request for Ordinance Amendment to allow bulk fuel storage/sales in an I - 1 (Light Industrial) District as a permitted or conditional use, including a Conditional Use Permit as required. Appli cant: Clear Creek Land Company, LLC. NAC) st Property: Legal : Lot 1, Block 1, Otter Creek Crossing 1 Addition, Outlot C, Otter Creek Crossing 1st Addition, and Oulot A, Otter Creek Crossing 3rd Addition. PIDs: 155 - 181 - 001010, 155 - 181 - 000010 and 155 - 194 - 000030 A ddress: 3360 Chelsea Rd Planning Case Number: ZZDAHL , 2016 - 2018 A. REFERENCE & BACKGROUND Request (s) : 1. A preliminary and final plat; 2. Amendment to Zoning Ordinance to allow Bulk Fuel Storage; 3. C onditional use permit to allow bulk fuel storage tanks in the I - 1 Industrial District; 4. Conditional Use Permit for joint parking and access; 5. Conditional Use Permit for building height; 6 . V ariance to the side yard setback . Deadline for Decision: July 16, 2016 Land Use Designation: Places to Work Zoning Designation: I - 1 Industrial The purpose of the "I - 1," light industrial, district is to provide for the establishment of warehousing and light industrial development . Overlays/Environmental Regulations Applicable: N / A Current Site Use: Industrial Beverage Warehouse/Distribution Surrounding Land Uses: North: Vacant B - 4, Regional Business District 1 P lanning Commission Agenda 06 / 0 7 / 201 6 East: Vacant I - 1, Industrial South: Vacant I - 1, Industrial West : I - 1, Industrial Project Description and Background : Clear Creek Land Company, LLC/ Dahlheimer Beverage is a wholesale distributer of beverages products in and around the Monticello region . The business currently occupies the site at 3360 Chelsea Rd. The site has a 54,595 square foot building which Dahlheimer /Rocky Mountain Group currently owns and occupies. The applicant seek s to build an expansion to the building by 97,055 square feet, as well as additional parking spaces, a truck wash, bulk fuel storage, and landscaping. The new total building will total 151,650 square feet. To accomplish the addition, the applicant is purchasing additional property to the south, for a total resultant land area of a pproximately 15 acres . The site fronts on Chelsea Road and a portion of Dalton Avenue NE. The new site will include additional frontage along Dalton Avenue NE, as well as Dalton Way along the southwest boundary. The site is zoned I - 1, Industrial. The purpose of the "I - 1," (L ight industrial ) D istrict is to provide for the establishment of warehousing and light industrial development . Dahlheimer Beverage as a warehousing use is an allowed use in the I - 1 District. A NALYSIS The applicants are seeking to purchase two city - owned outlots that are located to the southwest of their current property. Because the outlots require replatting to be developable, and applicant is seeking to replat the existing and proposed land for development and financing purposes. The replatting is proposed to create a lot line along the existing south building wall, and the addition will abut the new lot line, allowing for a single building that sits across the proposed lot line. This resu lts in the need to address what would otherwise be zoning issues for setback and cross - use. The applicants also propose to install a bulk fuel - tank storage facility for their delivery trucks. Currently, bulk fuel storage is not included as a use in the I - 1 District. To accommodate this proposal, the applicant wishes to amend the code to add the use to the district, and provide for a companion Conditional Use Permit to install the proposed fuel storage on the site. As noted above, the various applicati ons necessary to accommodate the proposal are as follows: 1. A preliminary and final plat; 2. Amendment to allow Bulk Fuel Storage; 2 P lanning Commission Agenda 06 / 0 7 / 201 6 3. Conditional use per mit to allow bulk fuel storage tanks in the I - 1 Industrial District; 4. Conditional Use Permit for joint parking and access; 5. Conditional Use Permit for building height; 6. Variance to the side yard setback. PRELIMINARY PLAT The applicants are seeking to combine the various parcels, both current and proposed, into two parcels. The existing located on Lot 2 , also with a zero lot line. The applicant is seeking this arrangement to accommodate ownershi p and financing requirements. They have asked for a variance to the required setbacks, which will be evaluated separately. The plat is consistent with the standard subdivision requirements, and does not raise any zoning issues, with the notations relatin g to setback and circulation discussed below. It should be noted that continued review related to the storm water management on the site may result in changes to drainage and utility easements for the plat. Exhibit Z of the condition of plat approval wil l require drainage and utility easements consistent Grading, Drainage, Stormwater Management, and Erosion Control Plan Requirements The applicants have submitted a stormwater management plan that directs stormwater to an onsite pond with an outlet to the existing pond east of the existing building. This is subject to further review by the City Engineer. Due to concerns over the capacity of the ponds in the area, the Engineer and the applicant are working to ensure that stormwater designs adequately address the needs of the site. It is expected that final resolution of the grading and drainage plans will be forthcoming prior to the final reviews of the project. The applicants are working with the City Engineer to design drainage in a way that will not result in a substantive impact to the submitted site plans. Utilities The City Engineer is reviewing utility access and designs for the site. Those comments will be incorporated in the staff recommendation. Access The site currently has three curb cuts alo n g Dalton Avenue and one along Chelsea Road . The applicant is proposing to close one curb cut on the northwest side of the 3 P lanning Commission Agenda 06 / 0 7 / 201 6 property on Dalton Avenue and opening a new one further to the so uth. All curb cuts are greater than 125 feet apart. With a future expansion, the applicant has illustrated a proposed thir d access on Dalton Way, which will be subject to the review and commen t of the City Engineer at the time of expansion. Easements The applicant has submitted a petition for vacation of the drainage and utility easements impacted by replatting of the outlots and lot. The vacation will be considered by the City Council. Plat perimeter and lot easements are required to be established per the Subdivision Ordinance standards and are illustrated on the plat documents. Other comments related to easements are as noted by the City Engineer nd in the comment letter of June 2 , 2016. ZONING AMENDMENT BULK FUEL STORAGE and CUP The applican t proposes to operate a bulk - fuel tank facility for the trucks which deliver for the business. Currently, bulk - fuel sales and storage is allowed in the B - 2, B - 3, and B - 4 districts as a permitted accessory use, as well as the CCD by Conditional Use Permit. This use (at least, the storage and dispensing of fuels to company vehicles) is a common accessory activity in i ndu strial areas, and likely occurs on a number of other local industrial properties. The current regulations are listed below, with additions or changes noted for the purposes of industrial applications: (10) Bulk Fuel Sales & Storage (a) All accessory use bulk fuel storage must be associated with retail sales the principal activity on the site. In Industrial Districts, accessory fuel dispensing shall not be available for sale to the public . (b) No more than one (1) bulk fuel tank con tainer shall be located on a parcel. (c) Accessory use bulk fuel sales/ storage tank containers shall be limited to 1000 gallons. (d) Accessory use bulk fuel sales/ storage may not be located within the required front yard setback. (e) Accessory use bulk fu els sales/ storage facilities shall include 1 shrub landscaping planting per every 10 feet of bulk fuel facility perimeter, planted in accordance with required safety clearances. (f) Accessory use bulk fuel sales/storage from all structures and public right of way. (g) Accessory use bulk fuel sales/ storage must include a containment structure and bollards for tank protection per applicable fire code or other regulations. (h) Accessory use bulk fuel sales/ storage facilities shall comply with all MPCA and State Fire Marshal requirements, all other permit, testing and listing requirements, and all applicable codes and standards such as NFPA 58. (i) Accessory us e bulk fuel sales/ storage facilities located within the Drinking 4 P lanning Commission Agenda 06 / 0 7 / 201 6 Water Supply Management Area (DWSMA) must comply with the City The changes suggested to the existing code language are inte nded to distinguish this use from the retail - oriented fuel dispensing (such as propane) that occurs in retail commercial areas. Staff would recommend inclusion of this language in the code, and adding the use to the I - 1 Industrial District as a Conditional Use Permit. The application and notice were constructed to provide for a request for conditional use permit for this use, sho u ld it be required. The Dahlheimer site plan proposal would be consistent with these standards. CONDITIONAL USE PERMIT BUILDING HEIGHT The current zoning ordinance language restricts buildings in the I - 1 District to 30 feet in height, with an allowance for greater height by Conditional Use Permit. The applicant seeks to match the existing building at a height of 32 feet. Subject to Fire Department review, no negative impact is envisioned by staff. CONDITIONAL USE PERMIT CROSS PARKING AND ACCESS T he ordinance provides a Conditional Use Permit process for vehicles to cross property lines between separate parcels without the normal need to separate the driveways and parking areas by curbed landscaped areas. The purpose of this CUP is to ensure that properties under separate ownership coordinate access points and maintenance responsibilities, and it allows vehicles to circulate internally without driving out to the public street. The process is most common in commercial areas. However, in this sit uation, the zero - lot - line subdivision requires consideration of the CUP approval. Because the subdivision creates a situation where the two parcels could conceivably be conveyed to separate owners, the CUP provision ensures that all subsequent owners will continue to be subject to the access provisions of these approvals. VARIANCE ZERO BUILDING SETBACK As noted, the applicants are seeking a variance request to construct a building expansion on the property line. The current property line would be moved to the east and placed along the edge of the existing building. The applicants seek to purchase two p arcels to the west of their property and create a new parcel. The building expansion would occur along the newly created parcel. The required internal side yard setback in the I - 1 District is normally 15 feet. The applicants have indicated that the buil ding expansion on the new parcel is necessary for financial reasons. 5 P lanning Commission Agenda 06 / 0 7 / 201 6 In reviewing variances, the Planning Commission sits as the Board of Adjustment. Variances are reviewed as to whether the proposed use is a reasonable one for the site and the localit y, and whether there are special circumstances that create practical difficulties in accommodating the use without a variance. The applicants note that the expansion is central to their operation, and requires a connected building to provide the services they offer. It is not uncommon that expansions of buildings such as this require separate financing that cannot be facilitated on a single parcel. Because the operational aspects of the site (including the cross - parking and access CUP) are subject to Cit y review, staff believes that the setback variances result in a reasonable use of the land as proposed. The City Code identifies five criteria when considering a variance: (i) The property in question cannot be put to a reasonable use if the provisions of t his ordinance are strictly applied. Staff Comment : The applicants are seeking a variance request to build a building expansion on a newly created property line. The applicants have indicated that the building expansion will be funded by a new loan and needs to be on a separate parcel of land. In order requirements, the applicants are proposing creating a new parcel of land. (ii) The circumstances rendering the property unusable are unique to the property. Staff Comment : Currently, the subject area contains three parcels of land. One is the parcel that is currently being used by the applicant. The other two are vacant lots owned by the City. One of the two vacant lots is 1.19 acres requirements for a 100 - foot lo t width. A parcel combination will remove this non - conformity. (iii) The circumstances rendering the property unusable were not created by the owner thereof. Staff Comment: The current parcel layout was not created by the property owners. (iv) A Variance, if granted, will not alter the essential character of the locality. Staff Comment: Granting the variance will greatly improve the subject site for expanded use and will not affect the character of the area. (v) Economic considerations alone sha ll not constitute a sufficient basis for a Variance if reasonable use for the property exists under the terms of the regulation. 6 P lanning Commission Agenda 06 / 0 7 / 201 6 Staff Comment: The applicants are seeking a variance to eliminate a non - conforming lot and create two new parcels of land. T he separate parcels are necessary for financial considerations. Currently, one of the parcels is not buildable. SITE PLAN REVIEW Parking and Circu l ation The applicants have provided a parking plan that shows 130 parking spaces proposed. The applicants have indicated that they will have 8,500 square feet of office space and 143,150 square feet of warehouse space. By code, the site should have 182 parking spaces. The applicants are proposing a deferred parki ng arrangement of 52 spaces. There is adequate space on the property to add future parking if it becomes necessary. Potential locations would include the future expansion areas to the southeast of the new building , along the future access drive to Dalton Way, or areas within the truck court that would n ot interfere with truck routing. The applicants should provide information relating to their employee counts to verify the adequacy of the current parking proposal. Location of Required Parking Required accessory off - street parking shall be on the same lot under the same owners h ip as the principal use being served except under the provisions of Section 4.8(G)(3). Staff Comment: The propo sed parcels and building are on two parcel s of land. However, the ownership of the two parcels will be the same, and the building will sit on the property line. As such, the applicant is seeking the Conditional Use Permit for cross parking and access. Curb Cuts and Access (i ) Each property shall be allowed one (1) curb cut access per one hundred twenty - five (125) feet of street frontage. All property shall be entitled to at least one (1) curb cut. Staff Comment: The site currently has three curb cuts along Dalton Avenue an d one along Chelsea Road. The applicant is proposing to close one curb cut on the northwest side of the property on Dalton Avenue and opening a new one further to the south. All curb cuts are greater than 125 feet apart. With a future expansion, the ap plicant has illustrated a proposed third access on Dalton Way, which will be subject to the review and comment of the City Engineer at the time of expansion. 7 P lanning Commission Agenda 06 / 0 7 / 201 6 (ii) The maximum driveway width between the public street and the property line shall not exceed twenty - four (24) feet. Staff Comment : The width of the new curb cut appears to be approximately thirty (30) feet at the widest point. The City Engineer can approve the wider curb cut desgn when necessary to accommodate expected traffic flow . Loading Bays (A) Purpose . The regulation of loading spaces in these zoning regulations is to alleviate or prevent congestion of the public right - of - way and so to pro mote the safety and general welfare of the public by establishing minimum requirements for off - street loading and unloading from motor vehicles in accordance with the utilization of various parcels of land or structures. (B) Location . 1) All required loading berths shall be off - street and located on the same lot as the building or use to be served. Staff Comment: The site plan shows ten new loading berths and five overhead doors that will be located on the southwest side of the building. They are accessed by a large paved area on the same parcel. The site also has five existing loading bays and three overhead doors that will remain. 2) The location of required loading births shall be such that circulation occurs within the design ated site or property and does not depend upon a public street or alley. Staff Comment: The new loading berths are accessed by a large paved area that is part of the same parcel. 3) All loading berth curb cuts shall be located at a minimum fifty (50) feet from the intersection of two (2) or more street right - of - ways. This distance shall be measured from the property line. Staff Comment: The loading area easily meets this requirement. 4) No loading berth shall be located closer than fifty (50) feet from a residential district unless within a structure. Staff Comment: The area is surrounded by other industrial zoning and commercial zoning. 5) Loading berths shall not occupy the front yard setbacks. 8 P lanning Commission Agenda 06 / 0 7 / 201 6 Staff Comment: The loading berths are located on the re ar of the property and easily meet the setback requirements. However, it is noted that the loading in this area faces a public street (Dalton Way) and would be visible as if a front yard location. The proposed loading area sits approximately 400 feet fro m the street right of way, and several feet below the level of the street. The applicant has proposed landscaping along the property boundary that will provide a screening effect for much of the length of the Dalton Way frontage. 6) Each loading berth shall be located with appropriate means of vehicular access to a street or public alley in a manner which will cause the least interference with traffic. Staff Comment: The loading berths and truck traffic through the site are designe d as a one - way traffic flow. The truck traffic is not expected to interfere with vehicle traffic on the public street. (C) Surfacing All loading berths and access - ways shall be improved with not less than six (6) inch class five base and two (2) inch bituminous surfacing to control the dust and drainage according to a plan submitted to and subject to the approval of the Community Development Department. Staff Comment: The loading berths a nd access ways are scheduled to be paved with bituminous materi al. This is subject to further review by the City Engineer. Landscaping Planting Standards. For Industrial uses, the following planting requirements are applicable: 4.0 ACI of canopy trees (including at least 1 evergreen tree) per acre + at least 1 shrub per every 10 feet of a building wall facing a public right - of - way. The building addition has approximately 690 feet of new building exposure to the public right of w ay, and as noted above, expands the site by about 5.4 acres. As such, the total planting requirement would be 69 shrubs and 22 caliper inches of trees. There are separate planting requirements for perimeter vehicular use areas (parking and circulation al ong the public street areas), planting islands within parking areas, and screening of certain uses (fuel storage and loading docks). The requirement for general planting, according to the ordinance, can be met by other site landscaping required for peri meter parking and driveway areas, of which there 9 P lanning Commission Agenda 06 / 0 7 / 201 6 for the site. It should be noted that th e applicant may choose to distribute the plantings to other areas of the site if desired. In addition to the base planting requirements, the zoning ordinance requires screening for loading areas facing the street, and for other exterior use areas (in this case, the proposed bulk fuel tank area). The site landscaping provides screening along the Dalton Avenue frontage t o accomplish this requirement. In addition, the planting areas along Dalton Way will screen views of the loading areas on the southwest wa ll of the building. Staff would encourage the applicant to consider relocating a portion of the proposed plantings to the area in the south along the stormwater pond to augment the screening of the loading areas. Lighting Plan The applicants have submitted a lighting plan as required in Section 4.1(D)(2)(c)(x). The light plan includes light fixtures around all sides of the property on the paved areas. The light fixtures are hooded at 90 degrees to aim light downward. The light does not exceed 0. 6 foot - candles at the property line. requirement of 1.0 foot - candle or less at the property lines. Sign Regulations The applicants have not submitted a sign plan. The applicants shall submit a sign plan for review by City Staff if changes are proposed to the signage on the site. B. ALTERNATIVE ACTIONS The applicant is seeking a number of approvals to accommodate the proposed expansion. The approvals are as follows: 1. Amendment to Zoning Ordinance to allow Bulk Fuel Storage; (Resolution PC - 2016 - 017) 2. C onditional use permit s to allow bulk fuel storage tanks in the I - 1 Industrial District; Joint Parking and Access; and Building Height; (Resolution PC - 2016 - 018) 3 . V ariance to the side yard setback requirements (Resolution PC - 2016 - 019) 4. A preliminary and final plat (Resolution PC - 2016 - 020) Decision 1. Resolution No. PC - 2016 - 017 , Ordinance Amendment for Bulk Fuel Storage/Sales 1. Motion to adopt Resolution No. PC - 2016 - 017, recommending approval of an ordinance amending the zoning ordinance adding accessory bulk fuel stora ge as a conditional use in the I - 1 and I - 2 zoning districts based on the findings in said resolution . 10 P lanning Commission Agenda 06 / 0 7 / 201 6 A. Motion to deny adoption of Resolution No. PC - 2016 - 017, based on findings to be identified at the public hearing. B. Motion to table action on the request and continue the hearing, based on findings to be stated at the hearing. Decision 2. Resolution No. PC - 2016 - 018 , Conditional Use Permits for Building Height, Bulk Fuel Sales/Storage and Cross Parking and Access A. Motion to adopt Resolution N o. 2016 - 018, recommending approval of conditional use permits for b uilding height, cross parking and access, a nd for bulk fuel storage in an I - 1, Light I ndus trial district, based on the findings in said resolution and subject to those conditions identified in Exhibit Z . B. Motion to deny adoption of Resolution No. PC - 2016 - 018, based on findings to be identified at the public hearing. C. Motion to table action on the request and continue the hearing, based on findings to be stated at the hearing. Decision 3. Resolution No. PC - 2016 - 019 , Variance to Setbacks A. Motion to adopt Resolution No. PC - 2016 - 018, approving the variance to side yard setback for Clear Creek La nd Company , LLC accommodating a zero - lot - line setback for a building expansion in the i - 1, light industrial district, based on the findings in said resolution and subject to conditions as identified in Exhibit Z . B. Motion to deny adoption of Resolution No. PC - 2016 - 018, based on findings to be identified at the public hearing. C. Motion to table action on the request and continue the hearing, based on findings to be stated at the hearing. Decision 4. Resolution No. 2016 - 020, Preliminary Plat of Clear Creek Addition A. Motion to adopt Resolution No. PC - 2016 - 0 20 , recommending approval of the preliminary plat of Clear Creek Addition , based on the findings in said resolution and conditions as identified in Exhibit Z . B. Motion to deny adoption of Resolution No. PC - 2 016 - 020 , based on findings to be identified at the public hearing. C. Motion to table action on the request and continue the hearing, based on findings to be stated at the hearing. 11 P lanning Commission Agenda 06 / 0 7 / 201 6 C. STAFF RECOMMENDATION Staff recommends approval of the site and building plans; including the ordinance amendment, conditional use permits, and variance based on findings in the related resolutions and subject to the conditions identified in Exhibit Z. The industrial use expan General Warehousing use is a permitted use in the I - 1 zoning district. Staff also recommends the preliminary plat; and the final plat , based o n findings in the related resolutions and subject to the conditions identified in Exhibit Z . D. SUPPORTING DATA A. Resolution 2016 - 017 (Ordinance Amendment) B. Resolution 2016 - 018 (Conditional Use Permits) C. Resolution 2016 - 019 (Variance) D. Resolution 2016 - 020 (Preliminary Plat) E. Ordinance No. 647, Draft F. Aerial Site Image G. Applicant Narrative H. Application Plan Sets, Including: a. Title Page b. Preliminary Plat/Site Plan c. Grading and Drainage Plan d. Storm Sewer Utility Plan e. Landscape Plan f. Storm Water Pollution Prevention Plan g. Existing Conditions and Removals Plan h. Details i. Truck Turning and Circulation Plan j. Site Lighting Plan k. Preliminary Plat l. ALTA Survey m. Building Elevations n. Final Plat o. Vacation of Easements Exhibit nd I. , 2016 Z. Conditions of Approval 12 P lanning Commission Agenda 06 / 0 7 / 201 6 EXHIBIT Z Amendment to Zoning Ordinan ce to allow Bulk Fuel Storage; Conditional use permits to allow bulk fuel storage tanks, Joint Parking and Access, and Building Height ; Variance to the side yard setback requirements, and Preliminary and F inal plat of Clear Creek Addition . 3360 Che lsea Road st Lot 1, Block 1, Otter Creek Crossing 1 Addition, Outlot C, Otter Creek Crossing 1st Addition, and Oulot A, Otter Creek Crossing 3rd Addition. PIDs: 155 - 181 - 001010, 155 - 181 - 000010 and 155 - 194 - 000030 . 1. Deferred Parking . The applicants provide a narrative on the number of parking spaces that are needed for their business. The applicants have shown on the site plan that the 52 spaces can easily be added if needed. 2. Cross parking and access agreement is applied and recorded against both parcels. 3. An encroachment agreement is executed should it be necessary to accommodate storm water ponding design. 4. A development agreement is executed addressing all improvements to the site. 5. Curb Cut Width. The curb cut width shall be reviewed by the City Engineer. 6. The Landscaping Plan is modified to add or move plant materials that will enhance the screening of the view of the loading docks from Dalton Way. 7. dated June 1, 2016, and the applicants continue to work with the City regarding stormwater management requirements. 8. Bulk fuel dispensing on the site shall only be for the fueling of company delivery vehicles, and shall meet all other requirements of the ap plicable zoning ordinance, along with required building and fire codes. 9. Any proposed signage changes shall be subject to the applicable sign ordinances and a separate permitting process. 10. The requirements of other City staff are complied with. 13 P lanning Commission Agenda 06 / 0 7 / 201 6 14 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-017 RECOMENDINGAPPROVALOFANORDINANCEAMENDINGTHEZONING ORDINANCEADDINGACCESSORYBULKFUELSTORAGEASA CONDITIONALUSEINTHEI-1ANDI-2ZONINGDISTRICTS WHEREAS ,theapplicanthassubmittedarequesttoinstallbulkfueldispensing storagetanksasanaccessoryuseonitsI-1,LightIndustrialzonedproperty;and WHEREAS, thezoningordinanceprovidesforsuchtanksinotherdistricts,butdoes notcurrentlyallowthemasanaccessoryuseintheI-1District;and WHEREAS ,thefuelingofcompanyvehiclesisacommonaccessoryactivityfor industrialfacilities;and WHEREAS, theMonticelloZoningOrdinanceprovidesaframeworkforallowing suchfacilitiesoncommercialandindustrialproperty;and WHEREAS ,theproposedamendmentwouldfacilitatetheallowanceforsuch facilitiesinareasonableandorderlymanner;and th WHEREAS, thePlanningCommissionheldapublichearingonJune7 ,2016onthe applicationandtheapplicantandmembersofthepublicwereprovidedtheopportunityto presentinformationtothePlanningCommission;and WHEREAS ,thePlanningCommissionhasconsideredallofthecommentsandthe staffreport,whichareincorporatedbyreferenceintotheresolution;and WHEREAS, thePlanningCommissionoftheCityofMonticellomakesthefollowing FindingsofFactinrelationtotherecommendationofapproval: 1.BulkFueldispensingandstorageisacommonandreasonableaccessoryactivity inindustrialareas. 2.TheConditionalUsePermitprocessaccommodatestheusewithreasonable controlstoensurecompatibilitywiththeintentofthedistrict. 3.Theproposedamendmentprohibitsretailsalestominimizethepotentialfor conflictsbetweenretailandindustrialtrafficinthearea. 4.Theproposedamendmentisconsistentwiththepurposeandintentofthe Industrialzoningdistrictsinwhichitiseffective. 1 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-017 NOW,THEREFORE,BEITRESOLVED ,bythePlanningCommissionoftheCityof Monticello,Minnesota,thatthePlanningCommissionherebyrecommendsthatthe MonticelloCityCouncilapprovestheordinance. th ADOPTED this7 dayofJune,2016,bythePlanningCommissionoftheCityof Monticello,Minnesota. MONTICELLOPLANNINGCOMMISSION By:_______________________________ BradFyle,Chair ATTEST: ____________________________________________ AngelaSchumann,CommunityDevelopmentDirector 2 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-018 RECOMENDINGAPPROVALOFCONDITIONALUSEPERMITSFOR BUILDINGHEIGHT,CROSSPARKINGANDACCESS,ANDFOR BULKFUELSTORAGEINANI-1,LIGHTINDUSTRIALDISTRICT WHEREAS ,theapplicanthassubmittedarequesttoconstructanadditiontoan existingbuilding;and WHEREAS, theadditionisdesignedtomatchtheexistingbuildingandutilize existingparkingandcirculationareasonthesite;and WHEREAS ,theadditionwillrequiretheapprovalofconditionalusepermitsfor buildingheight,cross-parkingandaccess,andbulkfuelstoragetofacilitatetheexpansionof theuseasproposed;and WHEREAS ,theimprovementsareconsistentwiththeintentandpurposeoftheI-1, LightIndustrialzoningdistrict;and WHEREAS, theimprovementswillnotcreateanyunanticipatedchangestothe demandforpublicservicesonoraroundthesite;and WHEREAS ,thestormwaterandotherimpactsoftheexpansionarebeingaddressed throughappropriateengineeringreview;and th WHEREAS, thePlanningCommissionheldapublichearingonJune7 ,2016onthe applicationandtheapplicantandmembersofthepublicwereprovidedtheopportunityto presentinformationtothePlanningCommission;and WHEREAS ,thePlanningCommissionhasconsideredallofthecommentsandthe staffreport,whichareincorporatedbyreferenceintotheresolution;and WHEREAS, thePlanningCommissionoftheCityofMonticellomakesthefollowing FindingsofFactinrelationtotherecommendationofapproval: 1.TheproposedimprovementsareconsistentwiththeintentandpurposeoftheI- 1,LightIndustrialDistrict. 2.Theproposedimprovementsareconsistentwiththeexistingandfutureland usesintheindustrialparkinwhichtheyarelocated. 3.Theimpactsoftheexpansionarethoseanticipatedbyindustrialdevelopment andareaddressedthroughstandardreviewandordinancesinplace. 4.Thebuildingheight,cross-parkingandaccess,andbulkfuelfacilitiesmeetthe intentandrequirementsoftheapplicablezoningregulations. 1 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-018 NOW,THEREFORE,BEITRESOLVED ,bythePlanningCommissionoftheCityof Monticello,Minnesota,thatthePlanningCommissionherebyrecommendsthatthe MonticelloCityCouncilapprovestheConditionalUsePermitsforBuildingHeight,Cross- ParkingandAccess,andBulkFuelStorage,subjecttotheconditionslistedinExhibitZas follows: 1. DeferredParking.Theapplicantsprovideanarrativeonthenumberofparking spacesthatareneededfortheirbusiness.Theapplicantshaveshownonthesiteplan thatthe52spacescaneasilybeaddedifneeded. 2. Crossparkingandaccessagreementisappliedandrecordedagainstbothparcels. 3. Anencroachmentagreementisexecutedshoulditbenecessarytoaccommodate stormwaterpondingdesign. 4. Adevelopmentagreementisexecutedaddressingallimprovementstothesite. 5. CurbCutWidth.ThecurbcutwidthshallbereviewedbytheCityEngineer. 6. TheLandscapingPlanismodifiedtoaddormoveplantmaterialsthatwillenhance thescreeningoftheviewoftheloadingdocksfromDaltonWay. 7. TherequirementsoftheCityEngineerareaddressedpertheEngineer’sletterdated June1,2016,andtheapplicantscontinuetoworkwiththeCityregardingstormwater managementrequirements. 8. Bulkfueldispensingonthesiteshallonlybeforthefuelingofcompanydelivery vehicles,andshallmeetallotherrequirementsoftheapplicablezoningordinance, alongwithrequiredbuildingandfirecodes. 9. Anyproposedsignagechangesshallbesubjecttotheapplicablesignordinancesand aseparatepermittingprocess. 10. TherequirementsofotherCitystaffarecompliedwith. th ADOPTED this7 dayofJune,2016bythePlanningCommissionoftheCityof Monticello,Minnesota. MONTICELLOPLANNINGCOMMISSION By:_______________________________ BradFyle,Chair 2 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-018 ATTEST: ____________________________________________ AngelaSchumann,CommunityDevelopmentDirector 3 CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC -2016-019 APPROVING VARIANCES FOR SIDE YARD SETBACKS FOR CLEAR CREEK LAND, LLC ACCOMMODATING ZERO -LOT -LINE SETBACKS FOR A BUILDING EXPANSION IN THE I-1, LIGHT INDUSTRIAL DISTRICT WHEREAS, the applicant has submitted a request to construct an addition to an existing building; and WHEREAS, the subject property is being platted to create a "zero -lot -line" arrangement between the existing building and the addition; and WHEREAS, the typical requirement in the I-1 District is for a side yard setback of 15 feet; and WHEREAS, the Zoning Ordinance provides for variance where the City finds that there are practical difficulties in putting a property to a reasonable use; and WHEREAS, the applicant has identified the need for the variances to finance and construct the addition; and WHEREAS, the setback variances do not create conflicts with public services or other land uses in the area; and WHEREAS, the setback variances will facilitate development that is consistent with the goals and objectives of the City's Comprehensive Plan and with the development of the industrial park; and WHEREAS, the Planning Commission held a public hearing on June 7th, 2016 on the application and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello makes the following Findings of Fact in relation to the recommendation of approval: 1. The proposed development and variances are consistent with the intent and purpose of the I-1, Light Industrial District. 2. The proposed development and variances are consistent with the existing and future land uses in the industrial park in which they are located. CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC -2016-019 3. The impacts of the expansion are those anticipated by industrial development and are addressed through standard review and ordinances in place. 4. The plat accommodates development consistent with the requirements of the applicable zoning regulations. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota, that the Planning Commission hereby approves the side yard setback variances as requested, subject to the applicable conditions listed in Exhibit Z as follows: 1. Deferred Parking. The applicants provide a narrative on the number of parking spaces that are needed for their business. The applicants have shown on the site plan that the 52 spaces can easily be added if needed. 2. Cross parking and access agreement is applied and recorded against both parcels. 3. An encroachment agreement is executed should it be necessary to accommodate storm water ponding design. 4. A development agreement is executed addressing all improvements to the site. 5. Curb Cut Width. The curb cut width shall be reviewed by the City Engineer. 6. The Landscaping Plan is modified to add or move plant materials that will enhance the screening of the view of the loading docks from Dalton Way. 7. The requirements of the City Engineer are addressed per the Engineer's letter dated June 1, 2016, and the applicants continue to work with the City regarding stormwater management requirements. 8. Bulk fuel dispensing on the site shall only be for the fueling of company delivery vehicles, and shall meet all other requirements of the applicable zoning ordinance, along with required building and fire codes. 9. Any proposed signage changes shall be subject to the applicable sign ordinances and a separate permitting process. 10. The requirements of other City staff are complied with. ADOPTED this 7t' day of June, 2016 by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION Brad Fyle, Chair 2 CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC -2016-019 ATTEST: Angela Schumann, Community Development Director CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-020 RECOMENDINGAPPROVALOFAPRELIMINARYPLATFOR CLEARCREEKADDITION WHEREAS ,theapplicanthassubmittedarequesttoconstructanadditiontoan existingbuilding;and WHEREAS, thesubjectpropertyconsistsofaseriesoflotsandlotremnants;and WHEREAS ,theproposedplatwillaccommodatetheexpansionofanexisting business;and WHEREAS ,theimprovementsareconsistentwiththeintentandpurposeoftheI-1, LightIndustrialzoningdistrict;and WHEREAS ,thestormwaterandotherimpactsoftheexpansionarebeingaddressed throughappropriateengineeringreview;and th WHEREAS, thePlanningCommissionheldapublichearingonJune7 ,2016onthe applicationandtheapplicantandmembersofthepublicwereprovidedtheopportunityto presentinformationtothePlanningCommission;and WHEREAS ,thePlanningCommissionhasconsideredallofthecommentsandthe staffreport,whichareincorporatedbyreferenceintotheresolution;and WHEREAS, thePlanningCommissionoftheCityofMonticellomakesthefollowing FindingsofFactinrelationtotherecommendationofapproval: 1.TheproposedplatisconsistentwiththeintentandpurposeoftheI-1,Light IndustrialDistrict. 2.Theproposedplatisconsistentwiththeexistingandfuturelandusesinthe industrialparkinwhichtheyarelocated. 3.Theimpactsoftheexpansionarethoseanticipatedbyindustrialdevelopment andareaddressedthroughstandardreviewandordinancesinplace. 4.Theplataccommodatesdevelopmentconsistentwiththerequirementsofthe applicablezoningregulations. NOW,THEREFORE,BEITRESOLVED ,bythePlanningCommissionoftheCityof Monticello,Minnesota,thatthePlanningCommissionherebyrecommendsthatthe MonticelloCityCouncilapprovesthePreliminaryandFinalPlatforClearCreekAddition, subjecttotheapplicableconditionslistedinExhibitZasfollows: 1 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-020 1. DeferredParking.Theapplicantsprovideanarrativeonthenumberofparking spacesthatareneededfortheirbusiness.Theapplicantshaveshownonthesiteplan thatthe52spacescaneasilybeaddedifneeded. 2. Crossparkingandaccessagreementisappliedandrecordedagainstbothparcels. 3. Anencroachmentagreementisexecutedshoulditbenecessarytoaccommodate stormwaterpondingdesign. 4. Adevelopmentagreementisexecutedaddressingallimprovementstothesite. 5. CurbCutWidth.ThecurbcutwidthshallbereviewedbytheCityEngineer. 6. TheLandscapingPlanismodifiedtoaddormoveplantmaterialsthatwillenhance thescreeningoftheviewoftheloadingdocksfromDaltonWay. 7. TherequirementsoftheCityEngineerareaddressedpertheEngineer’sletterdated June1,2016,andtheapplicantscontinuetoworkwiththeCityregardingstormwater managementrequirements. 8. Bulkfueldispensingonthesiteshallonlybeforthefuelingofcompanydelivery vehicles,andshallmeetallotherrequirementsoftheapplicablezoningordinance, alongwithrequiredbuildingandfirecodes. 9. Anyproposedsignagechangesshallbesubjecttotheapplicablesignordinancesand aseparatepermittingprocess. 10. TherequirementsofotherCitystaffarecompliedwith. th ADOPTED this7 dayofJune,2016bythePlanningCommissionoftheCityof Monticello,Minnesota. MONTICELLOPLANNINGCOMMISSION By:_______________________________ BradFyle,Chair ATTEST: ____________________________________________ AngelaSchumann,CommunityDevelopmentDirector 2 ORDINANCENO.647 CITYOFMONTICELLO WRIGHTCOUNTY,MINNESOTA ANORDINANCEAMENDINGTITLE10OFTHE MONTICELLOZONINGCODEFORTHEFOLLOWINGSECTIONS: TABLE5.4,ACCESSORYUSESBYDISTRICT,AND SECTION5.3(D)(10)TOADDBULKFUELSTORAGEASA CONDITIONALUSEINTHEI-1ANDI-2ZONINGDISTRICTS THECITYCOUNCILOFTHECITYOFMONTICELLO,MINNESOTA,HEREBY ORDAINS: Section1. Table5.4,AccessoryUsesbyDistrict,isherebyamendedtoaddBulkFuel Sales/StorageasaConditionalUseintheI-1andI-2Districts. Section2. Section5.3(D)(10)AccessoryBulkFuelSales/Storage (10)BulkFuelSales&Storage (a)Allaccessoryusebulkfuelstoragemustbeassociatedwithretailsalesthe principalactivityonthesite.InIndustrialDistricts,accessoryfueldispensing shallnotbeavailableforsaletothepublic. (b)Nomorethanone(1)bulkfueltankcontainershallbelocatedonaparcel. (c)Accessoryusebulkfuelsales/storagetankcontainersshallbelimitedto1000 gallons. (d)Accessoryusebulkfuelsales/storagemaynotbelocatedwithintherequired frontyardsetback. (e)Accessoryusebulkfuelssales/storagefacilitiesshallinclude1shrub landscapingplantingperevery10feetofbulkfuelfacilityperimeter,planted inaccordancewithrequiredsafetyclearances. (f)Accessoryusebulkfuelsales/storagemustbelocatednolessthan25’from allstructuresandshallbesetback10’fromallpropertylinesand20’fromany publicrightofway. (g)Accessoryusebulkfuelsales/storagemustincludeacontainmentstructure andbollardsfortankprotectionperapplicablefirecodeorotherregulations. (h)Accessoryusebulkfuelsales/storagefacilitiesshallcomplywithallMPCA andStateFireMarshalrequirements,allotherpermit,testingandlisting requirements,andallapplicablecodesandstandardssuchasNFPA58. (i)Accessoryusebulkfuelsales/storagefacilitieslocatedwithintheDrinking WaterSupplyManagementArea(DWSMA)mustcomplywiththeCity Engineer’srecommendationsforsiteandcontainmentarrangement. Section3. TheCityClerkisherebydirectedtomakethechangesrequiredbythisOrdinance aspartoftheOfficialMonticelloCityCode,Title10,ZoningOrdinance,andto renumberthetablesandchaptersaccordinglyasnecessarytoprovidetheintended effectofthisOrdinance.TheCityClerkisfurtherdirectedtomakenecessary correctionstoanyinternalcitationsanddiagramsthatresultfromsuch ORDINANCENO.647 amendments,providedthatsuchchangesretainthepurposeandintentofthe ZoningOrdinanceashasbeenadopted. Section4. ThisOrdinanceshalltakeeffectandbeinfullforcefromandafteritspassageand publication.RevisionswillbemadeonlineafteradoptionbyCouncil.Copiesof thecompleteZoningOrdinanceareavailableonlineandatMonticelloCityHall. ADOPTEDBY theMonticelloCityCouncilthis27rddayofJune,2016. CITYOFMONTICELLO __________________________________ BrianStumpf,Mayor ATTEST: ___________________________________ JeffO’Neill,CityAdministrator VOTINGINFAVOR: VOTINGINOPPOSITION: Project Narrative Request Background Proposed Improvements Approvals Required SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING SITE DESIGN CIVIL ENGINEERING EXISTING DRAINAGE AND UTILITY EASEMENTS AS DEDICATED ON EXISTING LOT 1, BLOCK 1, OTTER CREEK CROSSING 1ST ADDITION CONFLICT WITH PROPOSED BUILDING AND ARE TO BE VACATED. PROPOSED FINAL PLAT OF CLEAR CREEK ADDITION WILL RE -DEDICATE DRAINAGE AND UTILITY EASEMENTS AS APPROPRIATE. O T T R C I► � E E I C 0 I I N NUE N.E• NEW ACCESS L`I'ON AV RENAMED PROPOSED DA BLVD, (F K A. SCHOOL D, 4429) — ;"-8618 CONC. CURB & GUTTER PER EXISTING � BITTRAIOUS 4=42012'22' R=7 00 ----69.84---- b co ----369.13 411 7°49'43" -II 27, U T�� N� ! A T� Imo-- ------ 4° --- --- - 0 "—_-- N j � II S T � ---�_ ;. 5 C ��-S --- II rI 4 2 I N -30.0 I � I i IW 00 Z\ I a o r z O Ic 70 1 I PROPOSED BITUMINOUS TRAIL D U T L O T E O T T E R C R E E K C R O S S I N G m SITE DATA: EXISTING ZONING: 1-1 INDUSTRIAL n � Cc) G S 30 10 <�oo-i Q 6 OUTLOT C: 51,948 �mC)Co � I �n o CQ U C' I 5K ao� TOTAL = 646,230 oo w00 O PROPOSED LOT AREAS: I I D U T L O T E O T T E R C R E E K C R O S S I N G m SITE DATA: EXISTING ZONING: 1-1 INDUSTRIAL PARKING EXISTING LOT AREAS: 30 10 LOT 1: 376,663 SF = 8.65 AC 6 OUTLOT C: 51,948 SF = 1.19 AC 12 OUTLOT A: 217,619 SF = 4.99 AC 6 TOTAL = 646,230 SF = 14.83 AC O PROPOSED LOT AREAS: I N LOT 1: 216,683 SF = 4.97 AC (ABSTRACT TITLE) LOT 2: 159,977 SF = 3.67 AC (ABSTRACT TITLE) LOT 3: 269,569 SF = 6.19 AC (TORRENS TITLE) D U T L O T E O T T E R C R E E K C R O S S I N G m SITE DATA: EXISTING ZONING: 1-1 INDUSTRIAL PARKING EXISTING LOT AREAS: 30 10 LOT 1: 376,663 SF = 8.65 AC 6 OUTLOT C: 51,948 SF = 1.19 AC 12 OUTLOT A: 217,619 SF = 4.99 AC 6 TOTAL = 646,230 SF = 14.83 AC O PROPOSED LOT AREAS: N LOT 1: 216,683 SF = 4.97 AC (ABSTRACT TITLE) LOT 2: 159,977 SF = 3.67 AC (ABSTRACT TITLE) LOT 3: 269,569 SF = 6.19 AC (TORRENS TITLE) TOTAL = 646,230 SF = 14.83 AC EXISTING BUILDING AREA ON PROPOSED LOT 1: p o�I o I EXISTING BUILDING: 54,595 SF Z PROPOSED BUILDING AREAS ON PROPOSED LOTS 2 AND 3: PROPOSED BUILDING: 97,055 SF EXISTING FUTURE BUILDING: 49,386 SF BITUMINOUS EXISTING IMPERVIOUS AREA 211,182 sf = 4.85 acres PROPOSED IMPERVIOUS AREA 456,096 sf = 10.47 acres (INCLUDES FUTURE BUILDING AND PROOF PARKING) I I NET IMPERVIOUS AREA INCREASE 244,914 sf = 5.62 acres SETBACK: MINIMUM REQUIREMENTS LOCATION: BUILDING PARKING FRONT 30 10 INTERIOR SIDE 15 6 STREET SIDE 30 12 REAR YARD 15 6 PROJECT LOCATION PART OF THE NW4' AND SW4, SECTION 10 TOWNSHIP 121, RANGE 25, WRIGHT COUNTY, MINNESOTA. EXISTING LEGAL DESCRIPTION LOT 1, BLOCK 1, AND OUTLOT A, OTTER CREEK CROSSING 1ST ADDITION, AND OUTLOT C, OTTER CREEK CROSSING 3RD ADDITION, WRIGHT COUNTY, MINNESOTA. PROPOSED LEGAL DESCRIPTION LOTS 1 AND 2, BLOCK 1, CLEAR CREEK ADDITION, WRIGHT COUNTY, MINNESOTA. D D I � O I N - EXISTING ACCESS TO BE REMOVED EXISTING BITUMINOUS Tri A u EXISTING WETLAND BOUNDARY OUTLOT D DALTON AVENUE N.E. gCHOOL BLVD, RENAMED OTTER CREEK CROSSING/ 1,36D POND WATER ELEV• 6 (4/19/16)=928. ADDITION - _ R, r.i ITTER LEGEND: 0 40 80 120 GRAPHIC SCALE IN FEET SURVEY DATA SURVEY INFORMATION PROVIDED BY: MEYER ROHLIN LAND SERVICES 708 1st AVENUE NE BUFFALO, MN 55313 BENCHMARK: TOP NUT HYDRANT ON DALTON AVENUE SOUTHEAST CURB LINE LOCATED APPROXIMATELY 195 FT NORTHEAST OF DALTON WAY INTERSECTION. ELEV=943.27 EXISTING BOUNDARY — - - - - - - - — EXISTING WETLAND BOUNDARY ----------- PROPOSED LOT LINE ---------------- PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER PROPOSED BUILDING EXISTING BUILDING EXISTING EASEMENTS TO BE VACATED 9, Q) �ft Oj U Co� L O a) cc a W CD j Ea:O ■ a uu CoLW mN co Co 00 to to a: OZ w O O 00 W z Co Co Q z ZE W O O C Q Co w Q) I O N co co N Iv DO M I In O E I C ,O c C ~ �TI p o�I o I b Z I I O O� O�U EXISTING BITUMINOUS `ox I Q, mco TRAIL I O I p Oc�p.� I I z FILE NO. 00601 C: ai 3 C: 3: 45------ -- I I I I I I I EXISTING 00 O I �z ACCESS TO BE REMAIN I I I I i Q) �ft Oj U Co� L O a) cc a W CD j Ea:O ■ a uu CoLW mN co Co 00 to to a: OZ w O O 00 W z Co Co Q z ZE W O 4 Q Co N co co N lob lb C DO W O E I C ,O c WLj W p o�I o I U L O Z Ll O� O�U tit�o r�AW `ox I Q, mco O O p Oc�p.� c o� p 4j FILE NO. 00601 C: ai 3 C: 3: -cow ° ►�. V 00 O I �z U_ i O t v S C O '2 0 0 CD U O O D a ° q a O 3 C ��. CL 1 /1 Preliminary Plat 4 Q 00 O DO W W V LL, Q O O p V FILE NO. 00601 1 /1 Preliminary Plat CLEAR GREEK ADDITION KNOW ALL PERSONS BY THESE PRESENTS: That Rocky Mountain Exchange Holding Company 25254, LLC, a Minnesota limited liability company, owner of the following described property situated in the County of Wright, State of Minnesota, to wit: Lot 1, Block 1, OTTER CREEK CROSSING 1ST ADDITION. (Torrens Property) and Clear Creek Land Company, LLC, a Minnesota limited liability company, owner of the following described property situated in the County of Wright, State of Minnesota, to wit: Outlot A, OTTER CREEK CROSSING 1ST ADDITION and Outlot C, OTTER CREEK CROSSING 3RD ADDITION. (Abstract Property) Have caused the some to be surveyed and platted as CLEAR CREEK ADDITION and do hereby dedicate to the public for public use the drainage and utility easements as created by this plat. MONTICELLO PLANNING COMMISSION Be it known that at a meeting held on this day of 20 the Planning Commission of the City of Monticello, Minnesota, did hereby review and approve this plat of CLEAR CREEK ADDITION. Chairperson Secretary CITY COUNCIL, CITY OF MONTICELLO, MINNESOTA In witness whereof said Rocky Mountain Exchange Holding Company 25254, LLC, a Minnesota limited liability company, has caused these presents to be signed by its This plat of CLEAR CREEK ADDITION was approved and accepted by the City Council of the City of Monticello, Minnesota, at a regular meeting thereof held this proper officers this day of 20 day of 20 and said plat is in compliance with the provisions of Minnesota Statutes, Section 505.03, Subd. 2. STATE OF MINNESOTA COUNTY OF Greg Dahlheimer, Chief Manager Joe Dahlheimer, Secretary This instrument was acknowledged before me this day of 20 by Greg Dahlheimer, Chief Manager, and Joe Dahlheimer, Secretary of Rocky Mountain Exchange Holding Company 25254, LLC, a Minnesota limited liability company. Signature WRIGHT COUNTY SURVEYOR Mayor City Administrator (ivome r-nnteo) I hereby certify that in accordance with Minnesota Statutes, Section 505.021, Subd. 11, this plat has been reviewed and approved this day of Notary Public, County, Minnesota 20 My Commission Expires In witness whereof said Clear Creek Land Company, LLC, a Minnesota limited liability company, has caused these presents to be signed by its proper officers this day of 20 STATE OF MINNESOTA COUNTY OF Luke Dahlheimer, Chief Manager Todd Lorsung, Chief Financial Manager/Treasurer Nick Dahlheimer, Secretary This instrument was acknowledged before me this day of 20 by Luke Dahlheimer, Chief Manager, Todd Lorsung, Chief Financial Manager/Treasurer, and Nick Dahlheimer, Secretary of Clear Creek Land Company, LLC, a Minnesota limited liability company. gnature FOUR-ATA- Notary UR—ATti Notary Public, My Commission Expire ntea) -County, Minnesota I Trace C. McCoy, do hereby certify that this plat was prepared by me or under my direct supervision; that I am a duly Licensed Land Surveyor in the State of Minnesota; that this plat is a correct representation of the boundary survey; that all mathematical data and labels are correctly designated on this plat; that all monuments depicted on this plat have been, or will be correctly set within one year, that all water boundaries and wet lands, as defined in Minnesota Statutes, Section 505.01, Subd. 3, as of the date of this certificate are shown and labeled on this plat; and all public ways are shown and labeled on this plat. Dated this day of 20 STATE OF MINNESOTA COUNTY OF WRIGHT The foregoing Surveyor's Certificate was acknowledged before me this License No. 44531 9 E77/Zr -Z Trace C. McCoy, Licensed Land Surveyor Minnesota License No. 44531 day of 20 by Trace C. McCoy, Land Surveyor, Minnesota gnature FOUR -ATA Notary Public, My Commission Expire ntea) -County, Minnesota Wright County Surveyor WRIGHT COUNTY AUDITOR Pursuant to Minnesota Statutes, Section 272.12, there are no delinquent taxes on the land hereinbefore described on this plat and transfer entered this day of 20 rignt county Huaitor WRIGHT COUNTY TREASURER Pursuant to Minnesota Statutes, Section 505.021, Subd. 9, taxes payable for the year 20 20 Wright County Treasurer WRIGHT COUNTY RECORDER Deputy on the land hereinbefore described have been paid this I hereby certify that this instrument was filed in the office of the County Recorder for record on this M., and was duly recorded in Cabinet No. Sleeve as Document No. REGISTRAR OF TITLES, WRIGHT COUNTY, MINNESOTA I hereby certify that this instrument was filed in the office of the Registrar of Titles for record on this M., and was duly recorded in Certificate Number Volume , Page 4.4 'C3 I" Deputy day of Wright County Recorder day of 20 at o'clock day of 20 at Registrar of Titles, Wright County, Minnesota o'clock SHEET' '� OF' 2 SHEE'T'S C AR CR K ADDITION •� �// �'QO TTy��FST � S °ti�G�c otic, C c_ i- r- r- I 1 1/2" OPEN • 1 �I \L_L_C\ ��TC A r-\r�ITI/1n I -� Sp. 1/2" OPEN 1 S�°'A / \ A r, r � 112" OPER j L" r`" -rI� �� °12'22" R-760.00 �2 r n IL `J ^ L `'v✓ ^ r`G i � " 1C / /II `\ \\o� �`` r' �1'�.�• 0:�`L,a`'`_r 6 T> °_7OL�59.84112OPEN 'n° '00 'p r)�­ '` --27-49'43"- 4. Ss° 91�39'31, 36 ;; ✓� `•� 'd=-32039'31" R=600.00 L=285. 00 L=234.96 I L" 1 A=26°55'29„ 44 ,p°� ,' \� `gypD I W ` -11 . o C J f \ I II �?9 -A I w D ss X298 J I 1 m��� I \ la A WO m o m ���� `3�S / I P. K. 'NA* AIL mpul 1 1/2" OPEN I cc I o JOA \ �1/�� I i�� \ I co 1> to f*1 C \ ( I \ rn��Z �� cn o I \ OLn 7 \ i �� 1 �J� w� 2 oN wN C_ \ J �� �� I------so---- B L O C K 1 „ o 0A i t C J � �� I ;� > CC � I I 1 0.1 1/2" OPEN \ I � N 46'02'39" E 78.05 I i ,%\3606„ it -51 ' , ` DRAINAGE AND / \\�.-- 94.29 i i�b / -` UTILITY EASEM �ENT---< , \\ - c� pp G — ---388.90 �� I / \ jT I _ I 271.24 1 --- _ 79.24---00 cc ° 'p ,1g.N0 —__---- 419.1 p 00 Ile r � I OPEN I 1/2" OPEN o a o O D U) , 1 oM0)-A, M ------' Zo p P o oZ r\ inm�cDi�Z� 1 vmm�DD M� 71 0o I ' ..o j04j j�o 11S A, 0 60 120 180 GRAPHIC SCALE IN FEET 1 INCH = 100 FEET • DENOTES IRON MONUMENT FOUND O DENOTES IRON MONUMENTS SET, MARKED BY LICENSE NO. 44531 QQ DENOTES WRIGHT COUNTY MONUMENT FOUND Drainage and utility easements are shown thus. NI NI I I Being 12.00 feet in width, I unless = otherwise indicated, and adjoining plat -� boundary lines as shown on the plot. 0 C7 BEARING ORIENTATION: THE SOUTHEASTERLY LINE OF LOT 1, BLOCK 1, OTTER CREEK CROSSING 1ST ADDITION IS ASSUMED TO BEAR N41 '02'17"E. VICINITY MAP SECTION 10, T. 121, R. 25, WRIGHT COUNTY, MN 0 1000 2000 3000 GRAPHIC SCALE IN FEET 1 INCH = 1000 FEET SHEET 2 OF 2 SHEE'T'S P lanning Commission Agenda 06 / 0 7 / 2016 2B . P ublic Hearing Consideration of a request for Preliminary and Final Plat for Monticello High School , a request for rezoning to Planned Unit Development, including Development and Final Stage Planned Unit Development, and a requ est for amendment to Conditional Use Permit for K - 12 Education Use for Monticello High School . Applicant: Wold Architects & Engineers . (NAC ) Property: Legal : Lengthy legal; provided in title commitment PID Nos. 155011000172, 15550013302, 15501100 0212 A ddress: 5225 School Boulevard Planning Case Number: 2016 - 029, ZMISHS A. REFERENCE & BACKGROUND Request (s) : Rezoning to Planned Unit Development District Development Stage PUD for High School Expansion (Final Stage by City Council only) Preli minary and Final Plat for Monticello High School Addition Deadline for Decision: July 15, 2016 Land Use Designation: Places for Community Zoning Designation: (Existing): R - 1, Single Family Residential The purpose of the "R - 1" single family distric t is to provide for low density, single family, detached residential dwelling units and directly related complementary uses. (Proposed): The purpose of the Planned Unit Development (PUD) zoning district is to provide greater flexibility in the developmen t of neighborhoods and non - residential areas in order to maximize public values and achieve more creative development outcomes while remaining economically viable and marketable Overlays/Environmental Regulations Applicable: NA Current Site Use: School c ampus 1 P lanning Commission Agenda 06 / 0 7 / 2016 Surrounding Land Uses: North: Industrial/Commercial East: Church South: Low Density Residential/Public Park West: Mixed Residential Project Description : The Monticello School District is seeking to undertake a series of improvements to its p roperty and facilities along School Boulevard. Because various schools are sharing some of the outdoor spaces, the District is seeking to plat the property into a single parcel and one outlot (the baseball field), and provide facilities under a Planned Un it Development. The first phase of these improvements is an addition to the gym space at the northeast corner of the High School that will serve as a gymnastics facility. Additional improvements will be processed in one or more future phases. Under the rezoning to PUD contemplated with this application, no conditional use permit is required; rather the use and performance standards for the use will be prescribed in the PUD ordinance. ANALYSIS Planned Unit Development Use and Project Description . T he subject property currently consists of three separate parcels totaling just under 119 acres. The site is bounded by School Boulevard on the south, Fallon Avenue on the west, and Fenning Avenue (County 18) on the east. The site is home to Little Mounta in Elementary, Eastview Elementary, and Monticello High Schools, along with parking facilities serving each building, a variety of outdoor athletic areas, and a baseball field to the north of the site that borders Chelsea Road. As noted above, the first phase of improvements is proposed to be an expansion of the gym facilities at the High School. The addition will be slightly more than 9,000 square feet in area, attached to the northeast corner of the existing building. It will be accessible from a sha red internal hallway, and will have a separate entrance that connects by sidewalk to an existing parking area north of the existing building. The site plans show a paved entry court area, but do not connect to the east parking area. The PUD request is necessary to accommodate the multiple principal buildings on a single parcel, and further accommodates the mixing of uses over the entire site. 2 P lanning Commission Agenda 06 / 0 7 / 2016 The applicant has proposed a concept stage PUD plan for the site which illustrates the overall expectation fo r future site development , in addition to the propo sed first phase of expansion as well as the existing buildings and facilities on the property. The concept will be reviewed by Planning th Commission and City Council in a workshop on June 7 . The develo pment and final stage PUD request relate specifically to the first phase of expansion for the proposed gymnasium and the existing buildings and facilities on the site. Building Materials . The exterior of the proposed building is shown as architectural pr ecast concrete, with some translucent panels providing natural light. The building is expected to match the existing structure and materials. Parking . The facility is not adding to the student capacity of the building, and no other changes are planned as a part of this phase of the PUD project. The existing parking areas on the site will serve the facility. Landscaping the following rate for institutional uses: 14.0 caliper inches of tree planting per acre; and 1 shrub per 10 linear feet of exterior building. The proposed building addition is approximately 0.2 acres in area, with 195 linear feet of exposed building wall. This results in a requirement for 3 caliper inches of required tree planting and 20 shrubs. The landscaping plan shows 20 proposed shrubs, and more than 40 new perennial plants. No trees are shown on the plan. The landscaping section of the zoning ordinance specifies that tree plantings are to focus on front yar ds or those areas where there are differing land uses. Due to the nature of this site, this requirement is not applicable. Staff would suggest that the inclusion of the perennial plantings would be an adequate exchange for the 3 caliper inches of tree pl anting, approved under the PUD. Lighting . The applicants have not proposed any additional lighting as a part of this application. It is expected that some entrance lighting, as well as walkway lighting for the new sidewalk, may be intended as a part of the project. All lighting (including existing lighting on the site) is required to be shielded from view of neighboring property or right of way, and must not cast light onto adjoining properties. Compliance with these standards should be verified by the applicant as a part of the development approval process. Signage . No changes to signage is proposed as a part of this phase. 3 P lanning Commission Agenda 06 / 0 7 / 2016 Preliminary Plat The School District proposes to combine the existing separate parcels into a single lot, along with one outlo t that encompasses the existing baseball field along Chelsea Road. The PUD accommodates this type of subdivision, however, the applicants should clarify the decision to plat the outlot, rather than incorporate the ballfield into the primary lot, or create a separate parcel. The proposed main parcel consists of just over 110 acres, and the outlot is just over 8 acres in area. All lots meet the requirements of the zoning and subdivision ordinance , subject to those comments of the City Engineer B. AL TERNATIVE ACTIONS T he Planning Commission and City Council will me e t immediately prior to the those discussions raise policy or development details affecting the Gymnasium add ition, they should be included in the appropriate approval resolution for the Development Stage PUD. The required actions include recommendations for the following: 1. Rezoning to Planned Unit Development and Development Stage PUD Site Plan (Final Stage to be reviewed by City Council) 2. Preliminary Plat for Monticello High School Addition (Final Plat to be reviewed by City Council) Decision 1. Resolution No. PC - 2016 - 021, Rezoning and Development Stage Planned Unit Development. A. Motion to adopt Resolution No. PC - 2016 - 021, recommending approval of a rezoning to PUD, Planned Unit Development District (Ordinance No. 648), and Development Stage Approval of the Site Plan for High School addition, based on the findings in said resolution, and the conditions attached to this staff report as Exhibit Z. B. Motion to deny adoption of Resolution No. PC - 2016 - 021, based on findings to be identified at the public hearing. C. Motion to table action on the request and continue the hearing, based on findings to be stated at the hea ring. 4 P lanning Commission Agenda 06 / 0 7 / 2016 Decision 2. Resolution No. PC - 2016 - 022, Preliminary Plat for Monticello School District. A. Motion to adopt Resolution No. PC - 2016 - 022, recommending approval of the Preliminary Plat for Monticello High School Addition , based on the findings in sa id resolution. B. Motion to deny adoption of Resolution No. PC - 2016 - 022, based on findings to be identified at the public hearing. C. Motion to table action on the request and continue the hearing, based on findings to be stated at the hearing. C. STAFF REC OMMENDATION Staff recommends appro val of Decision 1, Alternative A . (Approval of the PUD), as we ll as Decision 2, Alternative A (Approval of Preliminary Plat), based on the findings in the resolutions for decision and with the conditions identified in Exh ibit Z. D. SUPPORTING DATA A. Resolution No. PC - 2016 - 021 (PUD) B. Resolution No. PC - 2016 - 022 (Plat) C. Ordinance No. 648, Draft D. Aerial Site Image E. Preliminary Plat Narrative F. Land Use Narrative G. Gymnasium Addition Plan H. Concept Narrative I. Storm Water Management Inform ation J. Monticello High School PUD/Plat Plans, including: 1) Title Page 2) Boundary Survey 3) Preliminary Plat 4) Final Plat 5) PUD Concept Plan 6) Existing Drainage Plan 7) Proposed Drainage Plan 8) Removals, Site and Geometric Plans 9) Grading, Utility and Erosion Control Plans 10) Det ails 11) High School Space and Use Elevations 12) Gymnastics Addition Roof Plan K. Z. Conditions of Approval 5 P lanning Commission Agenda 06 / 0 7 / 2016 EXH IBIT Z Development Stage Planned Unit Development and Preliminary Plat, Monticello High School Addition 5225 School Boulevard PID Nos. 155011000172, 15550013302, 155011000212 1. Verification of compliance with Lighting ordinance requirements on high school site . 2. Substitution of tree planting requirement with perennial plantings as shown in the approved landscapi ng plan. 3. 4. Compliance with the requirements of Wright County as related to the plat documents. 5. Conditions recommended by other City staff or the Planning Commission . 6 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-021 RECOMENDINGAPPROVALOFAREZONINGANDDEVELOPMENTSTAGE PLANNEDUNITDEVELOPMENTFORMONTICELLOSCHOOLDISTRICT WHEREAS ,theapplicanthassubmittedarequesttorezoneitsschoolcampusat 5225SchoolBoulevardtoPUD,PlannedUnitDevelopmentDistrict;and WHEREAS, theapplicantconcurrentlyproposestoplatthepropertyintooneparcel andoneoutlotwithmultipleprincipalbuildingsandshareduses;and WHEREAS ,thesiteisguidedforinstitutionalusesunderthelabel“Placesfor Community”intheCity’sComprehensivePlan;and WHEREAS, thepropertywillchangeinscopeandintensity,butnotlanduse;and WHEREAS ,theproposedPUD,alongwiththecompanionPlat,areconsistentwith thelong-termuseanddevelopmentofthepropertyforpublicschools;and WHEREAS, thePlanningCommissionheldapublichearingonJune7,2016onthe applicationandtheapplicantandmembersofthepublicwereprovidedtheopportunityto presentinformationtothePlanningCommission;and WHEREAS ,thePlanningCommissionhasconsideredallofthecommentsandthe staffreport,whichareincorporatedbyreferenceintotheresolution;and WHEREAS, thePlanningCommissionoftheCityofMonticellomakesthefollowing FindingsofFactinrelationtotherecommendationofapproval: 1. ThePUDprovidesanappropriatemeansoffurtheringtheintentofthe ComprehensivePlanforthesite. 2. Theuseofthesiteforpublicschoolsisconsistentwiththedirectionofthe ComprehensivePlanfor“PlacesforCommunity”. 3.TheimprovementsproposedforthesiteundertheDevelopmentStagePUD areconsistentwiththerequirementsofthezoningordinance. 4. Theproposedimprovementswillhavenegligibleimpactsonpublicservices, includingsewer,water,stormwatertreatment,ortraffic. 1 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-021 NOW,THEREFORE,BEITRESOLVED ,bythePlanningCommissionoftheCityof Monticello,Minnesota,thatthePlanningCommissionherebyrecommendsthatthe MonticelloCityCouncilapprovestheRezoningandDevelopmentStagePUD,subjecttothe conditionslistedinExhibitZasfollows: 1. VerificationofcompliancewithLightingordinancerequirements. 2. Substitutionoftreeplantingrequirementwithperennialplantingsasshowninthe approvedlandscapingplan. 3. CompliancewiththetermsoftheCityEngineer’sletterdatedJune1,2016. 4. ConditionsrecommendedbyotherCitystaff. ADOPTED this7thdayofJune,2016,bythePlanningCommissionoftheCityof Monticello,Minnesota. MONTICELLOPLANNINGCOMMISSION By:_______________________________ BradFyle,Chair ATTEST: ____________________________________________ AngelaSchumann,CommunityDevelopmentDirector 2 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-022 RECOMENDINGAPPROVALOFAPRELIMINARYANDFINALPLATFOR MONTICELLOHIGHSCHOOLADDITION WHEREAS ,theapplicanthassubmittedarequesttorezoneitsschoolcampusat 5225SchoolBoulevardtoPUD,PlannedUnitDevelopmentDistrict;and WHEREAS, theapplicantconcurrentlyproposestoplatthepropertyintooneparcel andoneoutlotwithmultipleprincipalbuildingsandshareduses;and WHEREAS ,thesiteisguidedforinstitutionalusesunderthelabel“Placesfor Community”intheCity’sComprehensivePlan;and WHEREAS, thepropertywillchangeinscopeandintensity,butnotlanduse;and WHEREAS ,theproposedPlat,alongwiththecompanionPUD,areconsistentwith thelong-termuseanddevelopmentofthepropertyforpublicschools;and WHEREAS, thePlanningCommissionheldapublichearingonJune7,2016onthe applicationandtheapplicantandmembersofthepublicwereprovidedtheopportunityto presentinformationtothePlanningCommission;and WHEREAS ,thePlanningCommissionhasconsideredallofthecommentsandthe staffreport,whichareincorporatedbyreferenceintotheresolution;and WHEREAS, thePlanningCommissionoftheCityofMonticellomakesthefollowing FindingsofFactinrelationtotherecommendationofapproval: 1. TheproposedPlatprovidesanappropriatemeansoffurtheringtheintentof theComprehensivePlanforthesite. 2. Theuseofthesiteforpublicschoolsisconsistentwiththedirectionofthe ComprehensivePlanfor“PlacesforCommunity”. 3.TheimprovementsproposedforthesiteunderthePlatandDevelopment StagePUDareconsistentwiththerequirementsofthezoningordinance. 4. Theproposedimprovementswillhavenegligibleimpactsonpublicservices, includingsewer,water,stormwatertreatment,ortraffic. 1 CITYOFMONTICELLO WRIGHTCOUNTY,MINNNESOTA PLANNINGCOMMISSION RESOLUTIONNO.PC-2016-022 NOW,THEREFORE,BEITRESOLVED ,bythePlanningCommissionoftheCityof Monticello,Minnesota,thatthePlanningCommissionherebyrecommendsthatthe MonticelloCityCouncilapprovestheRezoningandDevelopmentStagePUD,subjecttothe conditionslistedinExhibitZasfollows: 1. VerificationofcompliancewithLightingordinancerequirements. 2. Substitutionoftreeplantingrequirementwithperennialplantingsasshowninthe approvedlandscapingplan. 3. CompliancewiththetermsoftheCityEngineer’sletterdatedJune1,2016. 4. ConditionsrecommendedbyotherCitystaff. ADOPTED this7thdayofJune,2016,bythePlanningCommissionoftheCityof Monticello,Minnesota. MONTICELLOPLANNINGCOMMISSION By:_______________________________ BradFyle,Chair ATTEST: ____________________________________________ AngelaSchumann,CommunityDevelopmentDirector 2 ORDINANCENO.648 CITYOFMONTICELLO WRIGHTCOUNTY,MINNESOTA ANORDINANCEAMENDINGTITLE10OFTHEMONTICELLOCITYCODE, KNOWNASTHEZONINGORDINANCE,BYESTABLISHINGTHEMONTICELLO HIGHSCHOOLPUDASAZONINGDISTRICTINTHECITYOFMONTICELLO, ANDREZONINGTHEFOLLOWINGPROPERTYFROMR-1,SINGLEFAMILY RESIDENTIALDISTRICT,TOMONTICELLOHIGHSCHOOLPUD,PLANNED UNITDEVELOPMENT: LOT1,BLOCK1,ANDOUTLOTA,MONTICELLOHIGHSCHOOLADDITION THECITYCOUNCILOFTHECITYOFMONTICELLOHEREBYORDAINS : Section1.Section2.4(P)–PlannedUnitDevelopments,Title10–ZoningOrdinanceis herebyamendedbyaddingthefollowing: (XX)MonticelloHighSchoolPUDDistrict (a) Purpose.ThepurposeoftheMonticelloHighSchoolPUDDistrictis toprovideforthedevelopmentofcertainrealestatesubjecttothe Districtforpublicschoolbuildingsandrelatedlanduses. (b) PermittedUses.PermittedprincipalusesintheMonticelloHigh SchoolPUDDistrictshallbeschools,includingpre-school,K-12,and relatedadministrativeuses,subjecttotheapprovedFinalStage DevelopmentPlansdated_____,anddevelopmentagreementdated ____,2016,asmaybeamended. (c) AccessoryUses.Accessoryusesshallbethosecommonlyaccessory andincidentaltoprimaryandsecondaryschooluses,andas specificallyidentifiedbytheapprovedfinalstagePUDplans. (d) DistrictPerformanceStandards.Performancestandardsforthe developmentofanylotintheMonticelloHighSchoolPUDDistrict shalladheretotheapprovedfinalstagePUDplansanddevelopment agreement.Insuchcasewhereanyproposedimprovementisnot addressedbythefinalstagePUD,thentheregulationsoftheR-1, SingleFamilyDistrictshallapply. (e) Amendments.WherechangestothePUDareproposedinthemanner ofuse,density,siteplan,developmentlayout,buildingsize,mass,or coverage,oranyotherchange,theproposershallapplyforan amendmenttothePUDunderthetermsoftheMonticelloZoning 1 ORDINANCENO.648 Ordinance,Section2.4(P)(10).TheCitymayrequirethatsubstantial changesinoveralluseofthePUDpropertybeprocessedasanew project,includingazoningdistrictamendment. Section2. ThezoningmapoftheCityofMonticelloisherebyamendedtorezonethe followingdescribedparcelsfromR-1,SingleFamilyResidentialDistrictto MonticelloHighSchoolPUD,PlannedUnitDevelopmentDistrict: Lots1,Block1,MonticelloHighSchoolAddition Section3. TheCityClerkisherebydirectedtomarktheofficialzoningmaptoreflectthis ordinance.Themapshallnotberepublishedatthistime. Section4. TheCityClerkisherebydirectedtomakethechangesrequiredbythisOrdinance aspartoftheOfficialMonticelloCityCode,Title10,ZoningOrdinance,andto renumberthetablesandchaptersaccordinglyasnecessarytoprovidetheintended effectofthisOrdinance.TheCityClerkisfurtherdirectedtomakenecessary correctionstoanyinternalcitationsthatresultfromsaidrenumberingprocess, providedthatsuchchangesretainthepurposeandintentoftheZoningOrdinance ashasbeenadopted. Theordinanceinitsentiretyandmapshallbepostedonthe Citywebsiteafterpublication. ADOPTEDBY theMonticelloCityCouncilthis___dayof____,2016. __________________________________ BrianStumpf,Mayor ATTEST: ___________________________________ JeffO’Neill,Administrator AYES: NAYS: 2 ® HydroCAD Calculations Proposed Conditions June 1 , 201 6 Ms. Angela Schumann Community Development Director City of Monticello 505 Walnut Street, Suite 1 Monticello, MN 55362 Re: Monticello School District PUD - Concept Plan , Preliminary and Final Plat Plan Review L i ttle M ountain Elementary, Monticello High School and Eastview Family Center City Project No. Z ZMISD WSB Project No. 02596 - 2 50 Dear Ms. Schumann : We have reviewed the PUD concept proposal as prepared by Wold Architects and Engineers dated May 9, 2019 and the preliminary and final plat dated April 11, 201 6 , as prepared by Sunde Land Surveying , and offer the following comments . PUD Concept 1. The existing easterly full access from School Boulevard for Eastview Family Center is in close proximity to the intersection at CSAH 18 , creating potential vehicle s conflicts . Given the proposed use and circulation pattern for Eastview Family Center , this access should be modified to a right - out only. The applicant has indicated that the access from CSAH 18 will be used as the main entrance to the site for drop offs. Drivers will exit to CSAH 18 or School Boulevard , therefore a right - out only a t School Boulevard is feasible. 2. T he applicant shall provide a plan for how traffic will be managed on School Boulevard and Chelsea Road during events at the proposed stadium and track fiel d . Preliminary and Final Plat 3. T he plat dedicates a 40 - foo t wide right of way along Fallon Avenue from centerline . T his appears to be adequate for future widening and pathway facilities along the roadway . 4. Re - submit the fu ll size preliminary plat sheet showing the existing public utilities within existing documented easements for review. It does not appear that the existing storm sewer that extends west of the Hig h School is aligned within the existing easement. 5. Please have the applicant explain why a 10 - foot wide drainage and utility easement being proposed in certain segments along the north property line of Lot 1, Block 1 ? A 6 - foot wid e easement is the standard width along interior lot lines. 6. A ccording the survey, a segment of the existing pathway along School Boulevard adjacent the Eastview Family Center , is located outside of the right of way. A pathway easement shall be provided to the City for this pathway segment. 7. The final plat should include one overall sheet for the entire plat area. P lease give me a call at 763 - 271 - 3236 if you have any questions or comments regarding this letter. Thank you. Sincerely, WSB & Associates, Inc. Shibani K. Bisson, PE City Engineer cc: Steve Grittman, NAC skb PlanningCommissionAgenda:06/07/16 3C.CommunityDevelopmentDirector’sReport PlanningCommissionRecommendations rd TheCityCounciltookthefollowingactiononMay23 asrelatedtoitemsontheMayagenda ofthePlanningCommission: ConsiderationofarequestforAmendmenttotheMonticelloZoningOrdinancetoallow Entertainment/Recreation,IndoorCommercialuseintheB-3(HighwayBusiness)District;anda requestforConditionalUsePermit(CUP)relatedtoEntertainment/Recreation,IndoorCommercial useintheB-3(HighwayBusiness)District.Applicant:NextLevelBaseballandSoftballTraining, Inc. OrdinanceAmendmentapproved;EntertainmentRecreation,IndoorCommercialasa conditionaluseintheB-3. ConditionUsePermitapprovedwithconditionsasnoted. ConsiderationofarequestforPreliminaryandFinalPlatforMonticelloMiddleSchool; ConditionalUsePermitforSchools,K-12use;andAmendmenttotheOfficialMonticelloZoning MapforRezoningfromAgriculturalOpenSpace(A-O)DistricttoSingle-FamilyResidence(R-1) District.Applicant:WoldArchitects&Engineers PreliminaryandFinalPlatapprovedsubjecttoconditionsasnoted. RezoningtoR-1approved. ConditionalUsePermitapprovedsubjecttoconditionsasnoted. ConsiderationofarequestforConditionalUsePermitforSchools,K-12use;andAmendmentto theOfficialMonticelloZoningMapforRezoningfromAgriculturalOpenSpace(A-O)Districtto Single-FamilyResidence(R-1)District.Applicant:WoldArchitects&Engineers RezoningtoR-1approved. ConditionalUsePermitapprovedsubjecttoconditionsasnoted. ConsiderationofAmendmenttotheMonticelloZoningOrdinance,Chapter4,Section5–Signs,as relatedtocommunityeventsignage.Applicant:CityofMonticello Ordinanceamendmentapproved. ConsiderationofarequestforAmendmenttotheMonticelloZoningOrdinance,Chapter5,Section 4,asrelatedtotemporaryusepermitrequirementsforspecialevents Applicant:CityofMonticello Ordinanceamendmentapproved;CityCodeamendedtoincludeSpecialEventPermits. ConsiderationofreviewandcommentonMonticelloZoningOrdinance,Chapter4,Section5- Signsasrelatedtoelectronicbillboards. Councildidnotcallforanamendment. Community&EconomicDevelopmentTechnician KerryBurrihasresignedherpositionasCommunity&EconomicDevelopmentTechnician fortheCityofMonticellotopursueotheropportunities.Wewishherwellandhopetohire forthepositionwithinthenextmonth. 1 PlanningCommissionAgenda:06/07/16 GTSTrainingSessions PlanningCommissionersareencouragedtoconsiderattendanceatthesessionsofferedby GTS.ThereisfundingavailableinthePlanningandZoningbudgettoreimburse Commissionersforthecost. 2 Archived: Tuesday,May31,20163:55:24PM From: GTSEducationalEvents Sent: Tuesday,May31,20163:03:57PM To: AngelaSchumann Subject: RegisternowforLandUseworkshopsandgetcontinuingedcredits! Importance: Normal NewthisyearAICPcredits,updated contentandmore!