Loading...
Planning Commission Agenda 02-07-2017 AGENDA REGULAR MEETING - MONTICELLO PLANNING COMMISSION Tuesday, February 7th, 2017 - 6:00 p.m. Mississippi Room, Monticello Community Center Commissioners: Brad Fyle, Sam Murdoff, Marc Simpson, Lucas Wynne Council Liaison: Charlotte Gabler Staff: Angela Schumann, Steve Grittman (NAC), Jacob Thunander, John Rued 1. General Business A. Call to Order B. Consideration of approving minutes a. Regular Meeting Minutes – January 3rd, 2017 C. Citizen Comments D. Consideration of adding items to the agenda 2. Public Hearings A. Public Hearing - Consideration of a request for amendment to Conditional Use Permit for Development and Final Stage Planned Unit Development for multi- tenant specialty dental facility in a B-4 (Regional Business) District Applicant: bdh + young B. Public Hearing – Consideration of adoption of the Monticello 2017 Official Zoning Map Applicant: City of Monticello 3. Regular Agenda A. Consideration of a request for simple subdivision resulting in two buildable parcels in the R-1 (Single-Family Residence) District to facilitate right of way for 7th Street/Fallon Avenue, per City Ordinance Title 11, Chapter 1, Section 7 Applicant: City of Monticello B. Consideration for recommendation for appointment of Planning Commissioner C. Consideration of the Community Development Directors Report 4. Added Items 5. Adjournment Special Meeting Academy Room - 5:30 PM Planning Commission Vacancy Interviews 1 MINUTES REGULAR MEETING - MONTICELLO PLANNING COMMISSION Tuesday, January 3rd, 2017 - 6:00 p.m. Mississippi Room, Monticello Community Center Present: Brad Fyle, Linda Buchmann, Sam Murdoff, Marc Simpson Absent: Lucas Wynne Council Liaison: Charlotte Gabler Staff: Angela Schumann, Steve Grittman (NAC), Jacob Thunander, John Rued 1. General Business A. Call to Order Brad Fyle called the regular meeting of the Monticello Planning Commission to order at 6:00 p.m. B. Consideration of approving minutes a. Regular Meeting Minutes – December 6th, 2017 MARC SIMPSON MOVED TO APPROVE THE REGULAR MEETING MINUTES OF DECEMBER 6TH, 2017. SAM MURDOFF SECONDED THE MOTION. MOTION CARRIED, 3-0-1 WITH LINDA BUCHMANN ABSTAINING. C. Citizen Comments None. D. Consideration of adding items to the agenda Brad Fyle added to the agenda the resignation of Planning Commissioner Linda Buchmann. 2. Public Hearings A. Public Hearing – Consideration of adoption of the Monticello 2017 Official Zoning Map Applicant: City of Monticello Angela Schumann reminded the Planning Commission that each January they are asked to review the zoning map to recognize rezoning amendments from the previous year and to correct any errors. Changes to the Monticello Zoning Map included: Ordinance No. 644 – Rezoning the Monticello Middle School plat from A-0 to R-1; Ordinance No. 645 – Rezoning the Pinewood Elementary parcels from A-0 to R-1; Ordinance No. 649 – Rezoning the Monticello High School to Planned Unit Development; Ordinance No. 650 – Rezoning the Mills Fleet Farm Plat from B-4 to Planned Unit Development; Ordinance No. 651 – Rezoning from B-2 to Planned Unit Development for Lot 1, Block 2, Oakwood Industrial Park (Red Rooster); Ordinance No. 655 - Rezoning from B-4 to B-3 for Camping World Plat parcel; and Ordinance No. 656 – Rezoning from B-4 to B-3 for Lot 1, Block 1, 90th Street Addition (Moon Motors). No changes were made to the Shoreland Overlay District. 2 SAM MURDOFF MOVED TO ADOPT RESOLUTION NO. PC-2017-001 RECOMMENDING THE ADOPTION OF ORDINANCE NO. 6XX FOR THE 2017 CITY OF MONTICELLO OFFICIAL ZONING MAP, INCLUDING SHORELAND/FLOODPLAIN COMPANION MAP, BASED ON THE FINDINGS IN SAID RESOLUTION. MARC SIMPSON SECONDED THE MOTION. MOTION CARRIED, 3-0-1 WITH LINDA BUCHMANN ABSTAINING. B. Public Hearing – Consideration to amend the Monticello Zoning Ordinance, Chapters and Subsections as follows. Applicant: City of Monticello  Chapter 2, Section 4(F) – Site Plan Applications  Chapter 3, Section 4(E) – R-1: Single Family Residence District  Chapter 3, Section 4(F) – R-2: Single and Two Family Residence District  Chapter 4, Section 1(H) – Standards for Site Landscaping  Chapter 4, Section 1(J) – Zoning District Specific Landscaping Standards  Chapter 4, Section 5(J) – District Regulations  Chapter 4, Section 8(E) – Standards Applicable to All Uses  Chapter 5, Section 2(D) – Regulations for Civic and Institutional Uses  Chapter 5, Section 2(F) – Regulations for Commercial Uses  Chapter 5, Section 3(B) – General Standards and Limitations for Accessory Uses and Structures  Chapter 5, Section 4(E) - Specific Standards for Temporary Uses  Chapter 8, Section 2(B) – Lots  Chapter 8, Section 4(B) – Lots (Definitions) Angela Schumann presented a series of ‘housekeeping’ zoning ordinance amendments that were either errors in the text or inconsistencies between specific sections of code. These proposed changes have been collected over the past year and were detailed by Schumann: Chapter 2, Section 4(F) – Site Plan Applications Site plan applications are not identified by Minnesota State Statute for municipal planning. City Staff suggested changing the wording to be a “submittal”, rather than an “application”. Schumann stated that site plan review occurs with or prior to the issuance of a building permit Chapter 4, Section 1(H) – Standards for Site Landscaping Table 4-4 was proposed to require that tree plantings occur in the boulevard consistent with City Ordinance 8-3. Also suggested was the elimination of evergreen trees in the boulevard or the immediate area for “Single-family Detached and Multi-Family Dwellings with Less than 5 Units” and the “T-N District”. This proposal was included because of sight line concerns with evergreen trees. 3 Schumann added the location of canopy trees in the boulevard was consistent with past policy and practice of creating a canopy over streets. An amendment to strike the language in the T-N District table was also proposed. Currently, Section 1(H) and Section 1(J) are not consistent in their requirements and the proposed amendment would correct this error. A similar change would occur for the CCD and IBC District. Chapter 4, Section 1(J) – Zoning District Specific Landscaping Standards Schumann proposed adding tree plantings in the front and side yards for the T-N District. The option for planting evergreens was also eliminated. Chapter 4, Section 5(J) – District Regulations The proposed amendments are intended to avoid content-based regulation associated with “identification” or “directional” signs. The language in the section was proposed to keep current sign allowances in terms of number and size and to maintain consistency with other terms in code. Residential monument signs have been clarified for their location and timing of the construction. Civic and institutional allowances also amended to eliminate the identification reference. Directional signs were proposed to be stricken in their entirety by removing the title and inserting the language in the provisions for free- standing signs. Height, display limitations, and setback regulations were also proposed. Chapter 5, Section 2(D) – Regulations for Civic and Institutional Uses Civic and Institutional Uses are allowed two signs, but they must be consistent with monument sign regulations. Chapter 4, Section 8(E) – Standards Applicable to All Uses Proposed to remove parking on unimproved surfaces expect as specifically allowed by ordinance. Brad Fyle asked if any new regulations to off-street parking would be changed with the proposals. Schumann declined stating that was governed by a separate off-street parking regulation identified in the zoning ordinance. She referenced a table which provides the allowable parking areas for vehicles. Chapter 4, Section 8(E) – Standards Applicable to All Uses & Chapter 8, Section 4(B) – Lots (Definitions) Schumann suggested adding “Pre-” to the current text regulation for “K-12 Educational Institutions” as it reflects the changing educational system. A 4 corresponding alteration to the table and definitions section would be included. In addition, a clause would be added for buildings and structures to comply with all required building codes when modifications occur to accommodate early childhood functions. Chapter 5, Section 2(F) – Regulations for Commercial Uses City code state that “convenience retail” can operate from 6 a.m. to 9 p.m. The proposed amendment would allow convenience retail beyond the hours of 6 a.m. and 9 p.m. with Conditional Use Permit. Schumann stated this would allow the City to consider conditions which relate to land use impacts. Table 5-4 was proposed to eliminate the graphic symbols with text. Chapter 5, Section 3(B) – General Standards and Limitations for Accessory Uses and Structures This proposal included clarifying detached accessory structure could be located in side or rear yards, but behind the front line of the principle building. An exemption to commercial canopies and signs was also proposed. Chapter 5, Section 4(E) - Specific Standards for Temporary Uses An amendment would ensure that Table 5-6 would be consistent with Chapter 4, Section 5 for temporary sign duration of 120 days per calendar year. Chapter 8, Section 2(B) – Lots To be consistent with Chapter 5, Section 3, it was proposed to add detached accessory structures to be allowed in side yards, if they are behind the front line of the principal structure and meet the other requirements of Chapter 5, Section 3 (B)(3). Schumann also stated that Staff believed that these amendments corrected errors with the zoning ordinance, addressed the needs arising from changing conditions, and were consistent with achieving the goals and objectives outlined in the comprehensive plan. SAM MURDOFF MOVED TO ADOPT RESOLUTION NO. PC-2017-002, A RESOLUTION RECOMMENDING ADOPTION OF THE PROPOSED AMENDMENTS TO THE ZONING ORDINANCE BASED ON A FINDING THAT SUCH AMENDMENTS ARE CONSISTENT WITH THE CITY’S LONG-TERM LAND USE GOALS AND OTHER STATED FINDINGS IN SAID RESOLUTION. LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED, 4-0. 3. Regular Agenda 5 A. Consideration of a Review of the Special Use Overlay District Steve Grittman, NAC explained the purpose of the Special Use Overlay District defined in the Monticello Zoning Ordinance. The ordinance takes an approach to regulate adult-oriented uses and ensure there are eligible parcels for these types of businesses to locate in the city. City Staff, including the City Attorney, believe that the current ordinance and map meet this requirement. With recent development and land use changes, Grittman stated that staff evaluated this area again to ensure adult-oriented uses could be accommodated. Grittman stated that in review there have been very little changes affecting the overlay area in the past year and that the same amount of parcels were available for adult-oriented uses from the previous review. Grittman stated that no action was required if the Planning Commission was comfortable with no changes to the ordinance or map. The Planning Commission was in consensus for the Special Use Overlay District to remain the same. B. Consideration to Appoint 2017 Planning Commission Officers SAM MURDOFF MOVED TO NOMINATE COMMISSIONER BRAD FYLE AS CHAIR OF THE PLANNING COMMISSION FOR 2017. LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED, 4-0. MARC SIMPSON MOVED TO NOMINATE COMMISSIONER SAM MURDOFF AS VICE CHAIR OF THE PLANNING COMMISSION FOR 2017. LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED, 4-0. Angela Schumann stated that staff typically serves as Secretary by recording the minutes and keeping record of the agenda. The Planning Commission unanimously agreed to have staff serve as Secretary. C. Consideration to appoint a representative to the Downtown Small Area Study Steering Committee. Angela Schumann stated the EDA had selected the Cuningham Group to complete the Downtown Small Area Study. They would like to gather a group of people to serve on a steering committee to help guide the plan. The steering committee would meet three to four times with a timeline for completion in May, 2017. Schumann stated that staff was requested to bring forth a member from the Planning Commission to participate on the steering committee. Marc Simpson asked what the plan hoped to accomplish. Schumann stated that the plan would review the previous downtown study and create an updated land use plan for the defined area. SAM MURDOFF MOVED TO NOMINATE COMMISSIONER MARC SIMPSON AS THE PLANNING COMMISSION REPRESENTATIVE FOR THE DOWNTOWN SMALL AREA STUDY STEERING COMMITTEE. 6 LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED, 4-0. D. Consideration of the Community Development Directors Report The Planning Commission had no questions regarding the Director’s Report. 4. Added Items A. Resignation of Commissioner Linda Buchmann Brad Fyle thanked Planning Commissioner Linda Buchmann for her time and service on the board. Angela Schumann noted that the open position would be posted until January 30th and consideration for approval could be held during the February meeting. Previous applicants would be notified of the opening and the opportunity to apply again. SAM MURDOFF MOVED TO APPROVE THE RESIGNATION OF PLANNING COMMISSIONER LINDA BUCHMANN. MARC SIMPSON SECONDED THE MOTION. MOTION CARRIED, 4-0. 5. Adjournment SAM MURDOFF MOVED TO ADJOURN THE MEETING AT 6:42 P.M. LINDA BUCHMANN SECONDED THE MOTION. MOTION CARRIED, 4-0. Recorder: Jacob Thunander ____ Approved: February 7, 2016 Attest: ____________________________________________ Angela Schumann, Community Development Director Planning Commission Agenda – 02/07/2017 1 2A. Public Hearing – Public Hearing - Consideration of a request for amendment to Conditional Use Permit for Development and Final Stage Planned Unit Development for multi-tenant specialty dental facility in a B-4 (Regional Business) District. Applicant: bdh + young (NAC) Property:Legal: Lot 2, Block 1, Prairie Ponds PID: 155-157-001020 Planning Case Number:2017-006 A.REFERENCE & BACKGROUND Request(s):Planned Unit Development Approval for construction of a medical office building on an existing parcel within the Prairie Ponds PUD. Deadline for Decision:March 27th, 2017 (60 days from complete application) Land Use Designation:Places to Work Zoning Designation:B-4, Regional Business The purpose of the B-4, Regional Business District is to provide for the establishment of commercial and service activities which draw from and serve customers from the entire community or region. Overlays/Environmental NA Regulations Applicable: Current Site Use:Vacant Surrounding Land Uses: North:Stormwater Pond East:Highway 25, Commercial South:Commercial West:Vacant (Commercial Zoning) Project Description:The applicants propose to construct a medical office building (proposed as a dental clinic) on an existing parcel of 1.67 acres. The building is shown at 11,800 square feet, single story, at the east end of a parking lot of 49 spaces with access to the Deegan Court cul-de- sac. The building design includes a canopy that partially extends over a drop-off driveway at the main entrance. Planning Commission Agenda – 02/07/2017 2 ANALYSIS Ordinance Requirements:Within the B-4 District, Clinics and Medical Services are Permitted Uses, with no additional referenced conditions. As such, only the general provisions of the ordinance apply to the proposal. The PUD adds no additional requirements, as it was applied primarily to accommodate a plat with a variety of frontage and lot configurations. The B-4 District requires no setbacks, with the note that parking lot setbacks must be at least 6 feet from property lines, and generally not located within drainage and utility easements. Parking.The building is proposed at 11,800 square feet in area. The zoning ordinance requires one space per 250 square feet, for a total requirement of 47 spaces. The applicants site plan shows 49 spaces, as well as a row of 19 future (proof of parking) spaces along the north property boundary. As designed for current construction, the parking lot will not raise issues for headlight glare to the north, and no residential areas abut the property, although long views to residential areas are open across the stormwater pond. The inclusion of the future parking on the current plans should negate the need for future separate PUD amendment review of the parking lot expansion, although engineering/stormwater review would be required in any case. Landscaping.The applicant has provided landscaping plans that show landscaping areas in the parking lot islands, flanking the entrance driveway, and surrounding the building. The code requires landscaping quantities based on lot size and building perimeter. For this site, the total requirement is 2 evergreen trees and 16.7 caliper inches of deciduous trees, with 88 shrubs. The applicant’s plans meet this requirement, with 17.5 caliper inches of deciduous trees (5 overstory trees and 5 ornamental trees). Planning staff would note that if the parking area is added to the north, it may be prudent to require a buffer for headlight glare along the boundary. Due to the slope of the property, planting shrubs in this location now may mitigate need for fencing or other screening in the future. Lighting.A photometric plan has been submitted with the proposal. The purpose of photometric review is to ensure that light glare does not impact neighboring residential property or public rights of way. The proposed plan shows compliance with the City’s requirements in this regard. Staff would note that the plans identify site lighting as a “25 foot pole on a 3 foot base”. The requirements of the zoning Planning Commission Agenda – 02/07/2017 3 ordinance are a maximum height of 25 feet. The applicant should verify that the plan notes are consistent with this standard. Signage.The plan includes signage information on the building architectural plans. A monument sign is proposed to be located near the entrance drive to the site, with a sign cabinet area of just over 12 square feet. The sign is set on a concrete and brick base, with a total height of 4 feet, 10 inches. This is well within the allowances for such signs, which could accommodate freestanding sign height of 22 feet, and 100 square of area in most cases. In addition to the monument sign, the plans show building and tenant wall signage on the front wall (west facing the parking lot) and rear wall (east facing Highway 25). The plans do not detail the size of the wall signage. Scaling from the plans, planning staff estimates a total sign area of approximately 140 square feet between the six sign panels (three on each of the two wall facings). The zoning ordinance provides an allowance for such signage of up to 15% of the area of the walls facing each public street (up to 2 streets). In this case, the building façade area is more than 2,000 square feet along the Highway 25 exposure. This wall alone accommodates more than 300 square feet of wall sign area. As such, the plan is well within the limits of the ordinance. Building Design.The applicants propose a building of one story, with an average height of approximately 16 feet, and a varying parapet wall height that extends up to 22 feet at its highest. The building materials include concrete masonry block along the base wainscot, with the primary building exterior of EFIS (Exterior Finish Insulating System) – a stucco-like commercial building material. The building also uses metal accents, and glass. All materials are consistent with the City’s zoning requirements. Access and Circulation.The building gains its vehicular access from Deegan Court. Staff has discussed pedestrian access through or around the site, but because future pedestrian access to the north is uncertain at this time, due to grading and other factors, no pedestrian facilities are recommended by staff with this project. Utilities, Grading and Drainage.The City Engineer is reviewing the project for these aspects, and has included a separate report which is incorporated here by reference. Trash Handling.The trash handling enclosure is located in the northwest corner of the site, with access from the parking lot. The site is consistent with code requirements, and the facility itself is identified as “heavy duty concrete”, although Planning Commission Agenda – 02/07/2017 4 detail is necessary to confirm the materials. Staff would recommend that the materials are consistent with those used in the principal building. B.ALTERNATIVE ACTIONS Decision 1: Motion to adopt Resolution No. PC-2017-003, recommending approval of the amendment to PUD for Monticello Specialty Clinic, Prairie Ponds. 1.Motion to approve Resolution #PC-2017-003 recommending approval of the amendment to Prairie Ponds PUD, contingent on compliance with the findings in said resolution and those conditions specified in Exhibit Z. 2.Motion to deny Resolution #PC-2017-003 recommending for a PUD, based on findings to be made by the Planning Commission. 3.Motion to table action on the request, pending additional information as identified by the Planning Commission and staff report. C. STAFF RECOMMENDATION Staff recommends approval of the PUD, with the comments noted in Exhibit Z. The facility is consistent with the requirements of the zoning ordinance, and is an otherwise permitted use in the district. D. SUPPORTING DATA A.Resolution # PC-2017-003 B.Aerial Image, Subject Site C.Project Narrative D.Plan Set, including: a.Title Sheet b.Survey c.Site Plan d.Grading Plan e.SWPPP f.Utility Plan g.Site Details h.Lighting Plan i.Landscape Plan j.Preliminary Floor Plan k.Preliminary Elevations l.Revised Elevations E. City Engineer’s Letter, dated February 1st, 2017 Z.Conditions of Approval Planning Commission Agenda – 02/07/2017 5 EXHIBIT Z Monticello Specialty Clinic PUD Amendment Deegan Court Lot 2, Block 1, Prairie Ponds . 1.Verification of sign areas as consistent with the zoning ordinance. 2.Revise lighting plan to demonstrate compliance with light pole height requirements. 3.Provide shrub plantings along the north boundary to screen future parking expansion. 4.Verify trash enclosure materials will match building materials, consistent with code requirements. 5.Compliance with the terms and conditions of the City Engineer’s report, dated February 1st, 2017. 6.The applicant enter into a development agreement or proceedings for the amendment to PUD for Prairie Ponds. 7.Comments of other City Staff. CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC-2017-003 Motion By: Seconded By: RECOMENDING APPROVAL OF A DEVELOPMENT AND FINAL STAGE PLANNED UNIT DEVELOPMENT FOR CONSTRUCTION OF A SPECIALTY CLINIC AT LOT 2, BLOCK 1, PRAIRIE PONDS ADDITION WHEREAS, the applicant has submitted an application for approval of a Development/Final Stage PUD to construct a specialty clinic building on an existing platted parcel; and WHEREAS, the property in question is guided for institutional uses under the “Places to Shop” category in the Monticello Comprehensive Plan; and WHEREAS, the property in question is zoned B-4, Regional Business, in which such clinics are permitted uses; and WHEREAS, the property is subject to a Conditional Use Permit PUD, Planned Unit Development imposed at the time of the initial platting of the parcel; and WHEREAS, the proposed development is consistent with the requirements of the applicable zoning regulations; and WHEREAS, the proposed project will meet the goals and policies of the Monticello Comprehensive Plan; and WHEREAS, the Planning Commission held a public hearing on February 7th, 2017 on the application and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello hereby makes the following Findings of Fact in relation to the recommendation of approval: 1. The proposed project complies with the intent of the use of Planned Unit Development, and the original approvals granted to the subject PUD, in order to further the objectives for the area within the City Comprehensive Plan. 2. With conditions, Development and Final Stage PUD plans meet all applicable requirements of the City’s Zoning Ordinance. 3. The addition of clinic buildings and uses in the subject area is consistent with the City’s development objectives. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota, that the Planning Commission hereby recommends that the Monticello City Council approves the Rezoning and Development Stage PUD, subject to the conditions listed in Exhibit Z as follows: 1. Verification of sign areas as consistent with the zoning ordinance. 2. Revise lighting plan to demonstrate compliance with light pole height requirements. 3. Provide shrub plantings along the north boundary to screen future parking expansion. 4. Verify trash enclosure materials will match building materials, consistent with code requirements. 5. Compliance with the terms and conditions of the City Engineer’s report, dated February 1st, 2017. 6. The applicant enter into a development agreement or proceedings for the amendment to PUD for Prairie Ponds. 7. Comments of other City Staff. ADOPTED this 7th day of February, 2017, by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION By: _______________________________ Brad Fyle, Chair ATTEST: ____________________________________________ Angela Schumann, Community Development Director bdh + you ng - R equ est for Amend men t to Co nd ition al Use Permit Lot 2, Block 1, Prairie Ponds | PID #155157001020 C reated by : C ity of Monticello 385 ft www.bdhyoung.com 7001 France Avenue South Suite 200 Edina, Minnesota 55435 p 952.893.9020 f 952.893.9299 Monticello Specialty Clinic Building Project Narrative: The proposed Monticello Specialty Clinic Building is a multi-tenant 11,800 square foot single story steel framed facility located on a 1.67 acre site in the Prairie Ponds development. The site design includes 49 parking spaces with an additional 19 proof of parking spaces available for future expansion. The stormwater design includes a perforated storm vault system located below the parking lot to accommodate the required stormwater infiltration rates. The building design is a single story building with a flat roof and varying parapet heights. The building materials consist of brick, EIFS, CMU, anodized aluminum framed windows, and composite metal canopy and accent cornice elements. The mix of materials are used around the entire structure to create interest and rhythms along all four building façades. The roof line has varied heights with the introduction of metal cornice elements. The canopy provides covered drop off and pick up for patients and family members as well as metro mobility type vehicles. Landscaping is designed to complement the building architecture. The roof top mechanical unit will be fully screened with a corrugated metal enclosure of color to match the building materials. The trash enclosure located on the NW corner of the site will be constructed of materials matching the building construction. The building is designed as a multi-tenant specialty dental facility with primary business hours of 7:00 AM – 6:00 PM Monday through Friday with some weekend hours possible. The building is scheduled to begin construction in the spring of 2017 with completion by late summer of 2017. CONTACT LIST BUILDING OWNER DAVIS SERVICES REAL ESTATE GROUP 222 SOUTH 9TH STREET SUITE 3255 MINNEAPOLIS, MN 55402 MARK DAVIS EMAIL: MDAVIS@DAVISREALESTATEMN.COM PHONE: 612.341.3242 ARCHITECT BDH+YOUNG SPACE DESIGN 7001 FRANCE AVENUE SOUTH SUITE 200 EDINA, MN 55435 PATRICK J. GIORDANA, AIA EMAIL: PGIORDANA@BDHYOUNG.COM PHONE: 952-345-8306 CIVIL ENGINEER LOUCKS 7200 HEMLOCK LANE, SUITE 300 MAPLE GROVE, MN 55369 PJ DISCH P.E. EMAIL: PDISCH@LOUCKSINC.COM PHONE: 763.424.5505 LANDSCAPE ARCHITECT BRODSHO CONSULTING 698 NORTHBRIDGE COURT EAGAN, MN 55123 DEBRA BRODSHO EMAIL: DBRODSHO@AOL.COM PHONE: 651.688.8023 7001 France Avenue South, Suite 200, Edina, Minnesota 55435 952-893-9020 fax 952-893-9299 www.bdhyoung.com Project Information «=_ae=C=vçìåÖ=pé~ÅÉ= Sheet Title Sheet Information Job Code Drawn By Reviewed By DateD:\2017 Revit Local\A17-Davis_MontMB_mnafe@bdhyoung.com.rvt1/10/2017 2:49:31 PMjlkqf`biil pmb`f^iqv=`ifkf` jlkqf`biil uIuuu=pc qMKM ^Ja^sfpjlkq qfqib=pebbq uuLuuLuuuu hjc ae jlkqf`biil jlkqf`biil PRELIMINARY SHEET INDEX Sheet Number Sheet Name PRELIMINARYBID & PERMITFINAL SETTITLE 0.0 - GENERAL T0.0 TITLE SHEET CIVIL C1-1 EXISTING CONDITIONS C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 SITE UTILITY PLAN C8-1 SITE DETAILS SL-1 SITE LIGHTING PLAN LANDSCAPE 0.0 - GENERAL L1-1 LANDSCAPE PLAN PRELIMINARY PP02 PRELIMINARY FLOOR PLAN PP03 PRELIMINARY ELEVATIONS 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C1-1Plotted: 12 /21 / 2016 1:59 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND Gopher State One Call 13 EXISTING CONDITIONS C1-1 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C2-1Plotted: 12 /21 / 2016 2:0 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND SITE PLAN LEGEND CONCRETE SIDEWALK BITUMINOUS PAVEMENT Gopher State One Call CONCRETE PAVEMENT HEAVY DUTY BITUMINOUS PAVEMENT  23 CURRENT ZONING:B-4 PARKING SETBACK: 6 FT. BUILDING SETBACK:0 FT. PROPERTY AREA:1.668 AC EXISTING IMPERVIOUS AREA:0.000 AC. (0.00%) PROPOSED IMPERVIOUS AREA:1.042 AC (62.5%) SITE DATA SITE NOTES 1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL JURISDICTION REQUIREMENTS. 2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND LOCAL/STATE REQUIREMENTS. 3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5.TYPICAL FULL SIZED PARKING STALL IS 9' X20' WITH A 24' WIDE TWO WAY DRIVE UNLESS OTHERWISE NOTED. 6.ALL CURB RADII SHALL BE 3.0' UNLESS OTHERWISE NOTED. 7.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. OFF-STREET PARKING CALCULATIONS PROPOSED ACCESSIBLE PARKING: 4 STALLS REQUIRED ACCESSIBLE PARKING: 3 STALLS** **REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES FOR 51 TO 75STALLS ACCESSIBLE PARKING CITY REQUIREMENT: 4 STALLS PER 1,000 sf TOTAL PARKING REQUIRED = 11,800/1,000 X 4 = 47 STALLS PROPOSED SURFACE PARKING PROVIDED = 49 STALLS PROPOSED SURFACE PROOF OF PARKING PROVIDED = 19 STALLS PROPOSED TOTAL PARKING PROVIDED = 68 STALLS SITE PLAN C2-1 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C3-1Plotted: 12 /21 / 2016 2:1 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND Gopher State One Call 23 GRADING, DRAINAGE & EROSION CONTROL NOTES 1.SPOT ELEVATIONS REPRESENT FINISHED SURFACE GRADES, GUTTER/FLOW LINE, FACE OF BUILDING, OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2.CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BE SUMPED 0.16 FEET. RIM ELEVATIONS SHOWN ON PLANS DO NOT REFLECT SUMPED ELEVATIONS. 3.ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 4 INCHES OF TOP SOIL AND SEED/MULCH OR SOD. THESE AREAS SHALL BE WATERED/MAINTAINED BY THE CONTRACTOR UNTIL VEGETATION IS ESTABLISHED. 4.FOR SITE RETAINING WALLS "TW" EQUALS SURFACE GRADE AT TOP FACE OF WALL (NOT TOP OF WALL), "GW" EQUALS SURFACE GRADE AT WALL GRADE TRANSITION, AND "BW" EQUALS SURFACE GRADE AT BOTTOM FACE OF WALL (NOT BOTTOM OF BURIED WALL COURSES). 5.STREETS MUST BE CLEANED AND SWEPT WHENEVER TRACKING OF SEDIMENTS OCCURS AND BEFORE SITES ARE LEFT IDLE FOR WEEKENDS AND HOLIDAYS. A REGULAR SWEEPING SCHEDULE MUST BE ESTABLISHED. 6.DUST MUST BE ADEQUATELY CONTROLLED. 7.SEE SWPPP FOR ADDITIONAL EROSION CONTROL NOTES AND REQUIREMENTS. 8.SEE UTILITY PLANS FOR WATER, STORM AND SANITARY SEWER INFORMATION. 9.SEE SITE PLAN FOR CURB AND BITUMINOUS TAPER LOCATIONS. 10.SEE LANDSCAPE PLAN FOR FINAL SITE STABILIZATION. GRADING PLAN C3-1 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C3-2&3Plotted: 12 /21 / 2016 2:2 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND Gopher State One Call  23 SITE PLAN LEGEND SILT FENCE INLET PROTECTION EXISTING DRAINAGE PATTERN PROPOSED DRAINAGE PATTERN RECEIVING WATERS NAME OF WATER BODY TYPE OF WATER BODY SPECIAL WATER IMAIRED WATER PERMANENT STORMWATER MANAGEMENT INFILTRATION STORMWATER HARVEST AND REUSE FILTRATION WET SEDIMENTATION BASIN ONSITE PONDING ESTIMATED QUANTITIES DESCRIPTION UNIT TEMPORARY ROCK CONSTRUCTION ENTRANCE EA SILT FENCE (STANDARD)LF INLET PROTECTION EA QUANTITY 1 ! (% 7 TYPE OF SPECIAL WATER WOODFIBER BLANKET SF %" EROSION CONTROL BLANKET SITE BOUNDARY 1 MILE BUFFER AREA NO SPECIAL OR IMPAIRED WATERS WITHIN 1 MILE X SWPPP C3-2 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C3-2&3Plotted: 12 /21 / 2016 2:2 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS 1.PROJECT DESCRIPTION THE NATURE OF THIS PROJECT WILL CONSIST OF CONSTRUCTING A BUILDING AND PARKING LOT. UTILITY WORK NECESSARY FOR THE BUILDING AND DRAINAGE WILL ALSO BE CONSTRUCTED. 2.SEQUENCING OF MAJOR CONSTRUCTION ACTIVITIES ARE AS FOLLOWS: 1.INSTALL VEHICLE TRACKING BMP 2.INSTALL SILT FENCE AROUND SITE 3.INSTALL PROTECTIVE FENCE AROUND INFILTRATION AREAS 4.CLEAR AND GRUB SITE 5.STRIP AND STOCKPILE TOPSOIL 6.REMOVE PAVEMENTS AND UTILITIES 7.CONSTRUCT STORMWATER MANAGEMENT BASINS 8.INSTALL SILT FENCE AROUND BASINS 9.ROUGH GRADE SITE 10.IMPORT CLEAN FILL FOR REPLACEMENT AND BALANCE 11.INSTALL UTILITIES 12.INSTALL BUILDING FOUNDATIONS 13.INSTALL CURB AND GUTTER 14.INSTALL PAVEMENTS AND WALKS 15.FINAL GRADE SITE 16.REMOVE ACCUMULATED SEDIMENT FROM BASINS 17.CONSTRUCT INFILTRATION BASIN 18.SEED AND MULCH 19.WHEN ALL CONSTRUCTION ACTIVITY IS COMPLETE AND THE SITE IS STABILIZED, REMOVE SILT FENCE AND RESEED ANY AREAS DISTURBED BY THE REMOVAL. 3.SITE DATA: AREA OF DISTURBANCE:H13 PRE-CONSTRUCTION IMPERVIOUS AREA:H13 POST-CONSTRUCTION IMPERVIOUS AREA:H13 GENERAL SOIL TYPE:- 4.THE LOCATION OF AREAS NOT TO BE DISTURBED MUST BE IDENTIFIED WITH FLAGS, STAKES, SIGNS, SILT FENCE, ETC. BEFORE CONSTRUCTION BEGINS. 5.ALL DISTURBED GROUND LEFT INACTIVE FOR SEVEN (7) OR MORE DAYS SHALL BE STABILIZED BY SEEDING OR SODDING (ONLY AVAILABLE PRIOR TO SEPTEMBER 15) OR BY MULCHING OR COVERING OR OTHER EQUIVALENT CONTROL MEASURE. AT A RATE OF 1.5 TIMES STANDARD SEEDING FINAL STABILIZATION TO BE DONE PER LANDSCAPE PLAN, SEE SHEET L1-1. 6.ON SLOPES 3:1 OR GREATER MAINTAIN SHEET FLOW AND MINIMIZE RILLS AND/OR GULLIES, SLOPE LENGTHS CAN NOT BE GREATER THAN 75 FEET. DENOTES SLOPES GREATER THAN 3:1. ALL 3:1 SLOPES TO BE STABILIZED WITH EROSION CONTROL BLANKET 7.ALL STORM DRAINS AND INLETS MUST BE PROTECTED UNTIL ALL SOURCES OF POTENTIAL DISCHARGE ARE STABILIZED. 8.TEMPORARY SOIL STOCKPILES MUST HAVE EFFECTIVE SEDIMENT CONTROL AND CAN NOT BE PLACED IN SURFACE WATERS OR STORM WATER CONVEYANCE SYSTEMS. TEMPORARY STOCKPILES WITHOUT SIGNIFICANT AMOUNT OF SILT, CLAY, OR ORGANIC COMPOUNDS ARE EXEPMT EX: CLEAN AGGREGATE STOCK PILES, DEMOLITION CONCRETE STOCKPILES, SAND STOCKPILES. 9.SEDIMENT LADEN WATER MUST BE DISCHARGED TO A SEDIMENTATION BASIN WHENEVER POSSIBLE. IF NOT POSSIBLE, IT MUST BE TREATED WITH THE APPROPRIATE BMP'S. 10.SOLID WASTE MUST BE DISPOSED OF PROPERLY AND MUST COMPLY WITH MPCA DISPOSAL REQUIREMENTS. 11.THE WATERSHED DISTRICT OR THE CITY MAY HAVE REQUIREMENTS FOR INSPECTIONS OR AS-BUILT DRAWINGS VERIFYING PROPER CONSTRUCTION OF THE BMPS. 12.THE OWNER WHO SIGNS THE NPDES PERMIT APPLICATION IS A PERMITTEE AND IS RESPONSIBLE FOR COMPLIANCE WITH ALL TERMS AND CONDITIONS OF THE PERMIT. THE OPERATOR (CONTRACTOR) WHO SIGNS THE NPDES PERMIT APPLICATION IS A PERMITTEE FOR PARTS II.B., PART II.C, PART II.B-F, PART V, PART IV AND APPLICABLE CONSTRUCTION ACTIVITY REQUIREMENTS FOUND IN APPENDIX A, PART C. OF THE NPDES PERMIT AND IS JOINTLY RESPONSIBLE WITH THE OWNER FOR COMPLIANCE WITH THOSE PORTIONS OF THE PERMIT. 13.TERMINATION OF COVERAGE-PERMITTEE(S) WISHING TO TERMINATE COVERAGE MUST SUBMIT A NOTICE OF TERMINATION (NOT) TO THE MPCA. ALL PERMITTEE(S) MUST SUBMIT A NOT WITHIN 30 DAYS AFTER ONE OR MORE OF THE FOLLOWING CONDITIONS HAVE BEEN MET: A.FINAL STABILIZATION, PER NPDES PERMIT PART IV.G. HAS BEEN ACHIEVED ON ALL PORTIONS OF THE SITE FOR WHICH THE PERMITTEE IS RESPONSIBLE. B.TRANSFER OF OWNERSHIP AS DESCRIBED IN THE PERMIT. 15. INSPECTIONS A.INITIAL INSPECTION FOLLOWING SILT FENCE INSTALLATION BY CITY REPRESENTATIVE IS REQUIRED. B.EXPOSED SOIL AREAS: ONCE EVERY 7 DAYS AND WITHIN 24 HOURS FOLLOWING A 0.5" OVER 24 HOUR RAIN EVENT. C.STABILIZED AREAS: ONCE EVERY 30 DAYS D.FROZEN GROUND: AS SOON AS RUNOFF OCCURS OR PRIOR TO RESUMING CONSTRUCTION. E.INSPECTION AND MAINTENANCE RECORDS MUST BE RETAINED FOR 3 YEARS AFTER FILING OF THE NOTICE OF TERMINATION AND MUST INCLUDE: DATE AND TIME OF ACTION, NAME OF PERSON(S) CONDUCTING WORK, FINDING OF INSPECTIONS AND RECOMMENDATIONS FOR CORRECTIVE ACTION, DATE AND AMOUNT OF RAINFALL EVENTS GREATER THAN 0.5 INCHES IN A 24 HOUR PERIOD. 16. MINIMUM MAINTENANCE A.SILT FENCE TO BE REPAIRED, REPLACED, SUPPLEMENTED WHEN NONFUNCTIONAL, OR 1/3 FULL; WITHIN 24 HOURS B.SEDIMENT BASINS DRAINED AND SEDIMENT REMOVED WHEN REACHES 1/2 STORAGE VOLUME. REMOVAL MUST BE COMPLETE WITHIN 72 HOURS OF DISCOVERY. C.SEDIMENT REMOVED FROM SURFACE WATERS WITHIN (7)SEVEN DAYS D.CONSTRUCTION SITE EXITS INSPECTED, TRACKED SEDIMENT REMOVED WITH 24 HOURS. E.PROVIDE COPIES OF EROSION INSPECTION RESULTS TO CITY ENGINEER FOR ALL EVENTS GREATER THAN 12" IN 24 HOURS 17.THE SWPPP, INCLUDING ALL CHANGES TO IT, AND INSPECTIONS AND MAINTENANCE RECORDS MUST BE KEPT AT THE SITE DURING CONSTRUCTION ACTIVITY BY THE PERMITTEE(S) WHO HAVE OPERATIONAL CONTROL OF THE SITE. 18.OWNER MUST KEEP RECORDS OF ALL PERMITS REQUIRED FOR THE PROJECT, THE SWPPP, ALL INSPECTIONS AND MAINTENANCE, PERMANENT OPERATION AND MAINTENANCE AGREEMENTS, AND REQUIRED CALCULATIONS FOR TEMPORARY AND PERMANENT STORM WATER MANAGEMENT SYSTEMS. THESE RECORDS MUST BE RETAINED FOR THREE YEARS AFTER FILING NPDES NOTICE OF TERMINATION. 19.SWPPP MUST BE AMENDED WHEN: A.THERE IS A CHANGE IN DESIGN, OPERATION, MAINTENANCE, WEATHER OR SEASONAL CONDITIONS THAT HAS A SIGNIFICANT EFFECT ON DISCHARGE B.INSPECTIONS INDICATE THAT THE SWPPP IS NOT EFFECTIVE AND DISCHARGE IS EXCEEDING WATER QUALITY STANDARDS. C.THE BMP'S IN THE SWPPP ARE NOT CONTROLLING POLLUTANTS IN DISCHARGES OR IS NOT CONSISTENT WITH THE TERMS AND CONDITIONS OF THE PERMIT. D.AT ANY TIME AFTER PERMIT COVERAGE IS EFFECTIVE, THE MPCA MAY DETERMINE THAT THE PROJECT'S STORMWATER DISCHARGES MAY CAUSE, HAVE REASONABLE POTENTIAL TO CAUSE, OR CONTRIBUTE TO NON-ATTAINMENT OF ANY APPLICABLE WATER QUALITY STANDARD, OR THAT THE SWPPP DOES NOT INCORPORATE THE APPLICABLE REQUIREMENTS IN PART III.A.8., (IMPAIRED WATERS AND TMDLS). IF A WATER QUALITY STANDARD CHANGES DURING THE TERM OF THIS PERMIT, THE MPCA WILL AKE A DETERMINATION AS TO WHETHER A MODIFICATION OF THE SWPPP IS NECESSARY TO ADDRESS THE NEW STANDARD. IF THE MPCA MAKES SUCH DETERMINATION(S) OR ANY OF THE DETERMINATIONS IN PARTS III.B.1.-3., THE MPCA WILL NOTIFY THE PERMITTEE(S) IN WRITING. IN RESPONSE, THE PERMITTEE(S) MUST AMEND THE SWPPP TO ADDRESS THE IDENTIFIED CONCERNS AND SUBMIT INFORMATION REQUESTED BY THE MPCA, WHICH MAY INCLUDE AN INDIVIDUAL PERMIT APPLICATION. IF THE MPCA'S WRITTEN NOTIFICATION REQUIRES A RESPONSE, FAILURE TO RESPOND WITHIN THE SPECIFIED TIMEFRAME CONSTITUTES A PERMIT VIOLATION. 20.CONCRETE WASHOUT AREA A.CONTRACTOR TO PROVIDE PREFABRICATED CONCRETE WASH-OUT CONTAINER WITH RAIN PROTECTION PER PLAN. B.CONCRETE WASH-OUT TO BE IDENTIFIED WITH SIGNAGE STATING "CONCRETE WASHOUT AREA DO NOT OVERFILL". C.CONCRETE WASHOUT WATER NEEDS TO BE PUMPED WITHIN 24 HOURS OF STANDING WATER IN WASHOUT AREA. 21.IN THE EVENT OF ENCOUNTERING A WELL OR SPRING DURING CONSTRUCTION CONTRACTOR TO CEASE CONSTRUCTION ACTIVITY AND NOTIFY ENGINEER. 22.PIPE OULTETS MUST BE PROVIDED WITH TEMPORARY OR PERMANENT ENERGY DISSIPATION WITHIN 24 HOURS AFTER CONNECTION TO A SURFACE WATER. 23.FINAL STABILIZATION FINAL STABILIZATION REQUIRES THAT ALL SOIL DISTURBING ACVTIVITIES HAVE BEEN COMPLETED AND THAT DISTURBED AREAS ARE STABILIZED BY A UNIFORM PERENNIAL VEGETATIVE COVER WITH 70% OF THE EXPECTED FINAL DENSITY, AND THAT ALL PERMANENT PAVEMENTS HAVE BEEN INSTALLED. ALL TEMPORARY BMP'S SHALL BE REMOVED, DITCHES STABILIZED, AND SEDIMENT SHALL BE REMOVED FROM PERMANENT CONVEYANCES AND SEDIMENTATION BASINS IN ORDER TO RETURN THE POND TO DESIGN CAPACITY. 24. TEMPORARY SEDIMENTATION BASINS A.THE TEMPORARY SEDIMENTATION BASINS SHALL BE CONSTRUCTED AND MADE OPERATIONAL PRIOR TO DISTURBANCE OF 10 OR MORE ACRES DRAINING TO A COMMON LOCATION. B.TEMPORARY SEDIMENTATION BASINS ARE REQUIRED PRIOR TO RUNOFF LEAVING THE CONSTRUCTION SITE OR ENTERING SURFACE WATERS WHEN 10 OR MORE ACRES OF DISTURBED SOILS DRAIN TO A COMMON LOCATION. THE BASIN MUST PROVIDE 3,600 CUBIC FEET OF STORAGE BELOW THE OUTLET PER ACRE DRAINED. IF HYDRAULIC CALCULATIONS ARE AVAILABLE, THE TEMPORARY SEDIMENTATION BASIN MUST PROVIDE A STORAGE VOLUME EQUIVALENT TO THE 2-YEAR, 24-HOUR STORM, BUT IN NO CASE LESS THAN 1800 CUBIC FEET PER ACRE DRAINED. THE TEMPORARY SEDIMENTATION BASIN MUST BE CONSTRUCTED AND MADE OPERATIONAL CONCURRENT WITH THE START OF SOIL DISTURBANCE UP GRADIENT OF THE POND. THE TEMPORARY SEDIMENTATION BASIN SHALL BE DESIGNED TO PREVENT SHORT CIRCUITING. THE OUTFALL SHALL BE DESIGNED TO REMOVE FLOATABLE DEBRIS, ALLOW FOR COMPLETE DRAWDOWN OF THE POND FOR MAINTENANCE ACTIVITIES, AND HAVE ENERGY DISSIPATION. THE EMERGENCY SPILLWAY SHALL BE STABILIZED. C.TEMPORARY SEDIMENTATION BASINS SHALL BE SITUATED OUTSIDE OF SURFACE WATERS AND ANY REQUIRED BUFFER ZONE, AND MUST BE DESIGNED TO AVOID DRAINING WETLANDS, UNLESS THE IMPACT IS IN COMPLIANCE WITH THE REQUIREMENTS OF THIS PERMIT. D.EXCESSIVE SEDIMENT-LADEN WATER THAT IS NOT PROPERLY FILTERED WILL NOT BE PERMITTED TO DISCHARGE FROM SIRE. 25.DEWATERING AND BASIN DRAINING A.TURBID OR SEDIMENT-LADEN WATERS RELATED TO DEWATERING OR BASIN DRAINING SHALL BE DISCHARGED TO A TEMPORARY OR PERMANENT SEDIMENTATION BASIN ON THE PROJECT SITE UNLESS INFEASIBLE. THE TEMPORARY OR PERMANENT BASIN MAY DISCHARGE TO SURFACE WATERS IF THE BASIN WATER HAS BEEN VISUALLY CHECKED TO ENSURE ADEQUATE TREATMENT HAS BEEN OBTAINED IN THE BASIN AND THAT THE NUISANCE CONDITIONS WILL NOT RESULT FROM THE DISCHARGE. DISCHARGE POINTS SHALL BE ADEQUATELY PROTECTED FROM EROSION AND PROPER VELOCITY DISSIPATION PROVIDED. B.ALL WATER FROM DEWATERING OR BASIN-DRAINING ACTIVITIES MUST BE DISCHARGED IN A MANNER THAT DOES NOT CAUSE NUISANCE CONDITIONS, EROSION IN THE RECEIVING CHANNELS OR ON DOWN SLOPE PROPERTIES, OR INUNDATION IN WETLANDS CAUSING SIGNIFICANT ADVERSE IMPACTS TO THE WETLAND. C.IF FILTERS WITH BACKWASH WATERS ARE USED, THE BACKWASH WATER SHALL BE HAULED AWAY FOR DISPOSAL, RETURNED TO THE BEGINING OF THE TREATMENT PROCESS, OR INCORPORATED INTO SITE IN A MANNER THAT DOES NOT CAUSE EROSION. BACKWASH WATER MAY BE DISCHARGED TO SANITARY SEWER IF PERMISSION IS GRANTED BY THE SANITARY SEWER AUTHORITY. 26.POLLUTION PREVENTION A.BUILDING PRODUCTS THAT HAVE THE POTENTIAL TO LEACH POLLUTANTS MUST BE UNDER COVER TO PREVENT DISCHARGE OR PROTECTED BY AN EFFECTIVE MEANS DESIGNED TO MINIMIZE CONTACT WITH STORMWATER. B.PESTICIDES, HERBICIDES, INSECTICIDES, FERTILIZERS, TREATMENT CHEMICALS, AND LANDSCAPE MATERIALS MUST BE UNDER COVER. C.HAZARDOUS MATERIALS AND TOXIC WASTE MUST BE PROVIDED TO PREVENT VANDALISM. D.SOLID WASTER MUST BE STORED, COLLECTED AND DISPOSED OF IN COMPLIANCE WITH MINN. R. CH 7035. E.PORTABLE TOILETS MUST BE POSITIONED SO THAT THEY ARE SECURE AND WILL NOT BE TIPPED OR KNOCKED OVER. SANITARY WASTE MUST BE DISPOSED OF PROPERLY IN ACCORDANCE WITH MINN. R. CH 7041. F.DISCHARGE OF SPILLED OR LEAKED CHEMICALS, INCLUDING FUEL, FROM ANY AREA WHERE CHEMICALS OR FUEL WILL BE LOADED OR UNLOADED SHALL BE PREVENTED USING DRIP PANS OR ABSORBENTS. SUPPLIES SHALL BE AVAILABLE AT ALL TIMES TO CLEAN UP DISCHARGED MATERIALS AND THAT AN APPROPRIATE DISPOSAL METHOD MUST BE AVAILABLE FOR RECOVERED SPILLED MATERIALS. 27. DESIGN CALCULATIONS TEMPORARY & PERMANENT STORMWATER TREATMENT ARE DESIGNED TO MEET MPCA GENERAL & SPECIAL WATER REQUIREMENTS. CALCULATIONS ARE PART OF THE HYDROLOGY REPORT, WHICH IS TO BE CONSIDERED PART OF THE SWPP DOCUMENTS. SEE HYDROLOGY REPORT FOR ADDITIONAL INFORMATION. 28.GENERAL STORMWATER DISCHARGE REQUIREMENTS ALL REQUIREMENTS LISTED IN PART III OF THE PERMIT FOR DESIGN OF THE PERMANENT STORMWATER MANAGEMENT SYSTEM AND DISCHARGE HAVE BEEN INCLUDED IN THE PREPARATION OF THIS SWPP. THESE INCLUDE BUT ARE NOT LIMITED TO: A.THE EXPECTED AMOUNT, FREQUENCY, INTENSITY, AND DURATION PRECIPITATION. B.THE NATURE OF STORMWATER RUNOFF AND RUN-ON AT THE SITE. C.PEAK FLOW RATES AND STORWATER VOLUMES TO MINIMIZE EROSION AT OUTLETS AND DOWNSTREAM CHANNEL AND STREAM BANK EROSION. D.THE RANGE OF SOIL PARTICLE SIZES EXPECTED TO BE PRESENT ON THE SITE. 29.CONSTRUCTION OF FILTRATION BASINS A.NO HEAVY TRAFFIC ON FILTRATION AREAS. CONSTRUCTION TO BE DONE WITH MINIMAL COMPACTION COMPACTION TO FILTRATION AREAS. IF COMPACTION IS ENCOUNTERED, BASIN SOILS FOR THE FIRST & MUST BE REMOVED & RELAID. B.INFILTRATION SYSTEMS MUST NOT BE EXCAVATED TO FINAL GRADE UNTIL THE CONTRIBUTING DRAINAGE AREA HAD BEEN CONSTRUCTED AND FULLY STABILIZED UNLESS RIGOROUS EROSIN PREVENTION AND SEDIMENT CONTROLS ARE PROVIDED( PART III.D.1.C.). C.WHEN AN INFILTRATION SYSTEM IS EXCAVATED TO FINAL GRADE (OR WITHIN THREE (3) FEET OF FINAL GRADE), THE PERMITTEE(S) MUST EMPLOY RIGOROUS EROSION PREVENTION AND SEDIMENT CONTROLS (E.G., DIVERSION BERMS) TO KEEP SEDIMENT AND RUNOFF COMPLETELY AWAY FROM THE INFILTRATION AREA. THE AREA MUST BE STAKED OFF AND MARKED SO THAT HEAVY CONSTRUCTION VEHICLES OR EQUIPMENT WILL NOT COMPACT THE SOIL IN THE PROPOSED INFILTRATION AREA. D.TO PREVENT CLOGGING OF THE INFILTRATION OR FILTRATION SYSTEM, THE PERMITTEE(S) MUST USE A PRETREATMENT DEVICE SUCH AS A VEGETATED FILTER STRIP, SMALL SEDIMENTATION BASIN, OR WATER QUALITY INLET (E.G., GRIT CHAMBER) TO SETTLE PARTICULATES BEFORE THE STORMWATER DISCHARGES INTO THE INFILTRATION OF FILTRATION SYSTEM. 30.POST CONSTRUCTION THE WATER QUALITY VOLUME THAT MUST BE RETAINED ON SITE BY THE PROJECT'S PERMANENT STORMWATER MANAGEMENT SYSTEM DESCRIBED IN PART III.D. SHALL BE ONE (1) INCH OF RUNOFF FROM THE NEW IMPERVIOUS SURFACES CRATED BY THE PROJECT. SEE PART III.D.1. FOR MORE INFORMATION ON INFILTRATION DESIGN, PROHIBITIONS AND APPROPRIATE SITE CONDITIONS. 31.RESPONSIBILITIES A.THE OWNER MUST IDENTIFY A CONTRACTOR WHO WILL OVERSEE THE SWPPP IMPLEMENTATION AND THE PERSON RESPONSIBLE FOR INSPECTION AND MAINTENANCE: B.THE OWNER MUST IDENTIFY THE A PERSON WHO WILL BE RESPONSIBLE FOR LONG TERM OPERATIONS AND MAINTENANCE OF THE PERMANENT STORMWATER MANAGEMENT SYSTEM: 32.TRAINING REQEMENTS THE PERMITTES(S) SHALL ENSURE THE FOLLOWING INDIVIDUALS IDENTIFIED IN THIS PART HAVE BEEN TRIANED IN ACCORDANCE WITH THIS PERMIT'S TRAINING REQUIREMENTS. 1. WHO MUST BE TRAINED: A. INDIVIDUAL(S) PREPARING THE SWPPP FOR THE PROJECT B. INDIVIDUAL(S) OVERSEEING IMPLEMENTATION OF, REVISING, AND AMENDING THE SWPPP AND INDIVIDUALS(S) PERFORMING INSPECTIONS AS REQUIRED IN PART IV.E. ONE OF THESE INDIVDUAL(S) MUST BE AVAILABLE FOR AN ONSITE INSPECTION WITHIN 72 HOURS UPON REQUEST BY THE MPCA. C.INDIVIDUAL(S) PERFORMING OR SUPERVISING THE INSTALLATION, MAINTENANCE AND REPAIR OF BMPS. AT LEAST ONE INDIVIDUAL ON A PROJECT MUST BE TRAINED IN THESE JOB DUTIES. 2.TRAINING CONTENT: THE CONTENT AND EXTENT OF TRAINING MUST BE COMMENSURATE WITH THE INDIVIDUAL'S JOB DUTIES AND RESPONSIBILITIES WITH REGARD TO ACTIVITIES COVERED UNDER THIS PERMIT FOR THE PROJECT. AT LEAST ONE INDIVIDUAL PRESENT ON THE PERMITTED PROJECT SITE (OR AVAVILABLE TO THE PROJECT SIRE IN 72 HOURS) MUST BE TRAINED IN THE JOB DUTIES DESCRIBED IN PART III.F.1.B. AND PARTIII.F.1.C. 3.THE PERMITTEE(S) SHALL ENSURE THAT THE INDIVIDUALS ARE TRAINED BY LOCAL, STAT, FEDERAL AGENCIES, PROFESSIONAL OR OTHER ENTITIES WITH EXPERTISE IN EROSION PREVENTION, SEDIMENT CONTROL, PERMANENT STORMWATER MANAGEMENT AND THE MINNESOTA NPDES/SDS CONSTRUCTION STORMWATER PERMIT. AN UPDATE REFESHER-TREINING MUST BE ATTENDED EVERY THREE (3) YEARS STARTING THREE (3) YEARS FROM THE ISSUANCE DATE OF THIS PERMIT. 2.LIST OF CONTACTS * MPCA 24HR. HAZARDOUS SPILL HOTLINE: 651-649-5457 OF 80420798 SWPPP NOTES TITLE CONTACT OWNER X COMPANY PHONE NUMBER X X PROJECT MANAGER PJ DISCH LOUCKS 763-496-6736 SWPPP DESIGNER SAM TREBESCH LOUCKS 763-496-6751 CONTRACTOR SITE MANAGER TBD TBD SILT FENCE PRE-ASSEMBLED OR MACHINE SLICED 6" 6" NOTES: 1.PLACE BOTTOM EDGE OF FENCE INTO 6 IN DEEP TRENCH AND BACKFILL IMMEDIATELY. 2.POSTS SHALL BE: x 6 FT MAX. SPACING. x 2 IN X 2IN HARDWOOD, OR STANDARD STEEL T-TYPE FENCE POSTS. x 5' MIN. LENGTH POSTS, DRIVEN 2 FT INTO THE GROUND. 3.ATTACH FABRIC TO WOOD POST WITH A MIN. OF 5, 1 INCH LONG STAPLES. 4.ATTACH FABRIC TO STEEL POST WITH A MIN. OF 3 ZIP TIES IN TOP 8 INCHES OF FABRIC. GEOTEXTILE FABRIC PER MNDOT 3886 GEOTEXTILE FABRIC PER MNDOT 3886 DRAWN 2/2016 LOUCKS PLATE NO. 3000LOUCKS INLET PROTECTION - ROCK/COMPOST LOG BUTT JOINTS ENDS SECURELY CLOSED TO PREVENT LOSS OF OPEN GRADED AGGREGATE FILL. SECURED WITH 50 PSI. ZIP TIE 1 ROCK LOG/COMPOST LOG NOTES: SEE SPECS. 2573, 3137, 3886 & 3891. MANUFACTURED ALTERNATIVES LISTED ON Mn/DOT'S APPROVED PRODUCTS LIST MAY BE SUBSTITUTED. 1.GEOTEXTILE SOCK BETWEEN 4-10 FEET LONG AND 4-6 INCH DIAMETER. SEAM TO BE JOINED BY TWO ROWS OF STITCHING WITH A PLASTIC MESH BACKING OR PROVIDE A HEAT BONDED SEAM (OR APPROVED EQUIVALENT). FILL ROCK LOG WITH OPEN GRADED AGGREGATE CONSISTING OF SOUND DURABLE PARTICLES OF COARSE AGGREGATE CONFORMING TO SPEC. 3137 TABLE 3137-1; CA-3 GRADATION. DRAWN 2/2016 LOUCKS PLATE NO. 3014LOUCKS SWPPP NOTES C3-3 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C4-1Plotted: 12 /21 / 2016 2:3 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND Gopher State One Call  23 SITE UTILITY PLAN C4-1 UTILITY NOTES 1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS, THE CITY AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 1999 EDITION. ALL HDPE CONNECTIONS TO CONCRETE MANHOLES SHALL BE CONNECTED WITH AN INTERNAL RUBBER GASKET OR BY USING ADS WATERSTOP GASKET. ALL SANITARY SEWER MAIN LINE SHALL BE SDR 35. ALL SANITARY SEWER SERVICES SHALL BE SDR 26. 2. SEE SHEET C8-1 AND THE CONTRACT SPECIFICATIONS FOR SPECIFIC UTILITY DETAILS AND UTILITY SERVICE DETAILS. 3. ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL PER THE REQUIREMENTS OF THE CITY. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION. 4. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. 5. ALL SANITARY SEWER AND WATER SERVICES SHALL TERMINATE AT THE PROPERTY LINE UNLESS OTHERWISE NOTED. 6. THE CONTRACTOR SHALL NOTIFY GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS PRIOR TO PERFORMING ANY EXCAVATION OR UNDERGROUND WORK. 7. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5 FEET MINIMUM DEPTH CAN NOT BE ATTAINED. 8. ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY. 9. ALL NEW WATERMAIN MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. 10. ADJUST ALL EXISTING STRUCTURES, BOTH PUBLIC AND PRIVATE TO THE PROPOSED GRADES WHERE DISTURBED AND COMPLY WITH ALL REQUIREMENTS OF THE UTILITY OWNERS. STRUCTURES BEING RESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING. 11. PROPOSED PIPE MATERIALS: WATERMAIN DIP CLASS 52 NO LESS THAN 7.5' DEEP. SANITARY SEWER PVC SDR 35 NO MORE THAN 20' DEEP. SANITARY SEWER PVC SDR26 20' - 25' DEEP. STORM SEWER RCP CLASS 5 12" TO 18" DIAMETER. 12/21/16 CITY SUBMITTAL Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.16528A PJD SRT PJD X X LOUCKS W:\2016\16528A\CADD DATA\CIVIL\_dwg Sheet Files\C8-1Plotted: 12 /21 / 2016 2:3 PM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 EXISTING CONDITIONS SITE PLAN GRADING PLAN SWPPP SWPPP NOTES SITE UTILITY PLAN SITE DETAILS SITE DETAILS C8-1 LOUCKS 1'-0" SEE PLAN18'-0" DRAWN 1/2014 LOUCKS PLATE NO. 2035 DRAWN 1/2014 LOUCKS PLATE NO. 2036TYPICAL ADA WHEELCHAIR SYMBOL & PARKING SIGN "PARKING BY DISABLED PERMIT ONLY" ATTACH SIGN TO POST WITH APPROPRIATE STAINLESS STEEL BOLTS, WASHERS & NUTS. (TYP. AT TOP & BOTTOM OF SIGN) "VAN ACCESSIBLE" SIGN GRADE NOTES: 1.PROVIDE (1) SIGN PER STALL 2.SIGN MUST MEET LOCAL STANDARDS PROVIDE PAINTED WHEELCHAIR SYMBOL AT EACH DESIGNATED HANDICAP PARKING STALL. CENTER SYMBOL IN STALL. ALL LINES 5" WIDE 10" DIAMETER WHEELCHAIR SYMBOL NOT TO SCALE HANDICAP PARKING SIGN NOT TO SCALE 67.5ƒ 5ƒ "HANDICAP DROP-OFF ZONE NO PARKING" ATTACH SIGN TO POST WITH APPROPRIATE STAINLESS STEEL BOLTS, WASHERS & NUTS. (TYP. AT TOP & BOTTOM OF SIGN) GRADE NOTES: 1.PROVIDE (1) SIGN PER ACCESS AISLE 2.SIGN MUST MEET LOCAL STANDARDS HANDICAP ACCESS ISLE NO PARKING SIGN NOT TO SCALE LOUCKS SLOPE GUTTER TO MATCH PARKING LOT DRAINAGE (3/4" PER FT. TYP.) TIP GUTTER OUT AS REQ'D MINIMUM 1' BEHIND BACK OF CURBAGG. BASE UNDER CURB (IF TOTAL THICKNESS OF SECTION ALLOWS) 12"8" 1/2" RAD. 20" DRAWN 1/2014 LOUCKS PLATE NO. 2012FLAT CURB AND GUTTER (12") SPECIFICATION NOTES: 1.UPON COMPLETION, CURBING SHOULD BE SPRAYED WITH A MEMBRANE CURING COMPOUND PER MNDOT 3754. 2.EXPANSION JOINTS AT MAX. SPACING OF 200'. 3.CONSTRUCT IN ACCORDANCE WITH MNDOT 2531. LOUCKS LIGHT DUTY BITUMINOUS SECTION 2" BIT. WEARING COURSE MN/DOT SPEC. 2360 MN/DOT SPEC. 3138 (100% CRUSHED) 2" BITUMINOUS NON-WEAR COURSE MN/DOT SPEC. 2360 10" AGG. BASE CLASS 5 2357 TACK COAT MVWE35035 MVNW35035 HEAVY DUTY BITUMINOUS SECTION DRAWN 1/2014 LOUCKS PLATE NO. 2031BITUMINOUS PAVEMENT SECTION PAVEMENT SECTION BASED ON GEOTECHNICAL REPORT BY X DATED X/X/X 1.5" BIT. WEARING COURSE MN/DOT SPEC. 2360 MN/DOT SPEC. 3138 (100% CRUSHED) 2" BITUMINOUS NON-WEAR COURSE MN/DOT SPEC. 2360 8" AGG. BASE CLASS 5 2357 TACK COAT APPROVED SUBGRADE (SEE GEOTECHNICAL REPORT) MVWE35035 MVNW35035 APPROVED SUBGRADE (SEE GEOTECHNICAL REPORT) LOUCKS NOTES 1. CONTRACTOR SHALL INSTALL REQUIRED CMP, PIPE BENDS AND TEES TO CONNECT PIPES AT THE LIMITS OF THE UNDERGROUND PIPE SYSTEM FOOTPRINT. (SEE UTILITY PLAN) 2. 4" PVC DRAINTILE SHALL FOLLOW 48" CMP PIPES AS SHOW ABOVE AROUND THE PERIMETER OF THE PIPE SYSTEM. CONTRACTOR SHALL INSTALL TEES AS NECESSARY TO CONNECT DRAINTILE OUTLET MANHOLE. 48" CMP 48" CMP 4" SLOTTED SINGLE WALL HDPE PIPING WITH CIRCULAR KNIT POLYMERIC FILAMENT FILTER SOCK PER ASTM D6707-01 FREE DRAINING ANGULAR WASHED STONE 2" TO 3" MAX. PARTICLE SIZE NO CARBONATE 12" FREE DRAINING GRAVEL SAND (GW, GP, GM 0R SW) PARTICLE SIZE - 0.02-0.04 INCHES 18" 48" FILTER FABRIC SEPARATOR 12"24" FILTER FABRIC SEPARATOR 6" 6" IE= 949.0 IE= 948.5 IE= 947.0 IE= 953.0 IE= 953.5 (2) 100 LF OF 48" PERFORATED CMP WITH (2) HEADERS SEE SHEET C4-1 FOR LAYOUT 12" LOUCKS PLATE NO. 48" STORM VAULTLOUCKS PAGE 1 OF 1Drawn By: SANDYDate:12/16/2016Scale: AS NOTEDRevisions# Date CommentsGENERAL NOTES:A. PULSE PRODUCTS DOES NOT ASSUME RESPONSIBILITYFOR THE INTERPRETATION OF THIS CALCULATION ORCOMPLAINCE TO THE LOCAL, STATE, OR FEDERALLIGHTNG CODES OR ORDINANCES.B. LIGHTING LAYOUT IS NOT INTENDED FOR CONSTRUCTIONDOCUMENTS BUT ONLY TO ILLUSTRATE THE PERFORMANCEOF THE PRODUCT.C. ALL READINGS/CALCULATIONS SHOWN ARE SHOWN ONOBJECTS/SURFACES.D. MN ENERGY CODE MEET FOR LPD BUILDING METHOD OFFICE 0.9 LPW ALLOWED.MEETING MN ENERGY CODE WOULD REQUIRE:1. 0-10V DIM CONTROL FOR BI-LEVEL REQUIRED.2. SENSORS IN ALL PRIVATE OFFICES AND RESTROOMS3. AUTOMATIC OFF THROUGHOUT OPEN AREAS.MONTICELLOChecked By: TRENTLuminaire Location SummaryLumNoLabelXYZOrientTiltCalculation SummaryLuminaire ScheduleLabelCalcTypeUnitsAvgMaxMinAvg/MinMax/MinSymbolQtyLabelArrangementLLFDescriptionArr. WattsLum. Lumens4AASINGLE0.900MCGRAW GLEON-AF-04-LED-E1-5WQ MOUNT ON 25FT POLE WITH 3FT ABSE2252529126AA233.5301.428SITE GROUNDIlluminanceFc1.304.10.01BBSINGLE0.900MCGRAW GLEON-AF-04-LED-E1-T3 MOUNT ON 25FT POLE WITH 3FT BASE22524017900N.A.N.A.PARKINGIlluminanceFc2.6727AA129.7296.32890028AA128.3231.62890029AA210.12322890030BB131.6157.528168.33603.71.12.433.36PARKING HCIlluminanceFc1.471.81.11.341.64PROOF OF PARKIGN NORTHIlluminanceFc0.891.10.61.481.83Plan ViewScale: 1 inch= 30 Ft.DIM?NO PARKING NO PARKINGPROPOSEDBUILDINGFFE - 961.00TTNH=962.82959.3HCTCTTAPPROX LOC ELEPER CO MARKINGSAPPROX LOCGAS &TEL PER CO MARKINGSAAAAAABBAA0.2 0.2 0.2 0.2 0.10.1 0.2 0.3 0.4 0.4 0.4 0.3 0.2 0.1 0.00.2 0.3 0.5 0.6 0.7 0.7 0.6 0.3 0.1 0.1 0.1 0.1 0.10.2 0.4 0.7 0.9 1.0 1.2 1.1 0.6 0.2 0.1 0.1 0.1 0.1 0.1 0.10.1 0.3 0.5 0.9 1.2 1.4 1.7 1.8 1.1 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.10.1 0.10.1 0.3 0.6 1.1 1.5 1.8 2.1 2.5 1.8 0.5 0.3 0.3 0.2 0.2 0.2 0.2 0.10.1 0.1 0.1 0.1 0.10.2 0.3 0.7 1.2 1.8 2.3 2.5 2.8 2.7 0.8 0.6 0.5 0.4 0.3 0.3 0.2 0.20.2 0.2 0.2 0.1 0.10.2 0.3 0.7 1.3 2.0 2.8 2.9 2.9 3.0 1.6 0.9 0.7 0.5 0.4 0.4 0.4 0.30.3 0.3 0.2 0.2 0.2 0.20.1 0.2 0.4 0.7 1.3 2.1 3.1 3.4 3.1 3.2 2.8 1.4 0.9 0.7 0.6 0.6 0.50.5 0.4 0.4 0.3 0.3 0.2 0.20.2 0.2 0.4 0.7 1.3 2.1 3.3 4.0 3.8 3.8 3.5 1.8 1.2 1.0 0.8 0.8 0.70.6 0.6 0.5 0.5 0.4 0.4 0.3 0.20.2 0.3 0.4 0.8 1.3 2.1 3.2 4.1 3.8 3.3 3.4 1.8 1.4 1.2 1.1 1.0 0.90.8 0.8 0.7 0.6 0.5 0.5 0.4 0.30.2 0.3 0.5 0.8 1.3 2.0 3.0 3.8 3.7 3.6 3.8 1.9 1.5 1.5 1.4 1.3 1.21.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.30.2 0.3 0.5 0.8 1.3 2.0 2.9 3.6 3.7 3.9 4.1 2.2 1.8 1.8 1.7 1.5 1.41.3 1.2 1.1 1.0 0.9 0.7 0.6 0.4 0.30.2 0.4 0.5 0.8 1.3 2.0 2.8 3.4 3.7 4.0 4.1 2.8 2.1 2.0 2.0 1.9 1.81.7 1.6 1.4 1.3 1.1 0.9 0.7 0.50.3 0.4 0.6 0.9 1.3 1.9 2.7 3.3 3.6 3.9 3.9 3.2 2.4 2.2 2.2 2.3 2.22.2 2.0 1.8 1.6 1.3 1.0 0.8 0.60.3 0.5 0.7 0.9 1.3 1.9 2.6 3.2 3.5 3.7 3.7 3.3 2.7 2.4 2.5 2.6 2.62.5 2.3 2.1 1.8 1.4 1.1 0.9 0.70.3 0.5 0.7 1.0 1.3 1.8 2.5 3.0 3.3 3.7 3.5 3.3 3.0 2.7 2.8 2.9 2.82.9 2.6 2.3 2.0 1.6 1.3 1.0 0.80.3 0.5 0.7 1.0 1.4 1.9 2.4 2.9 3.1 3.4 3.4 3.3 3.1 2.9 3.0 3.0 3.03.0 2.7 2.4 2.2 1.8 1.4 1.2 0.9 0.70.2 0.3 0.5 0.8 1.1 1.4 1.9 2.3 2.7 3.0 3.2 3.3 3.2 3.1 3.0 3.0 3.13.1 2.9 2.8 2.5 2.2 1.9 1.5 1.3 1.0 0.80.2 0.3 0.5 0.8 1.1 1.4 1.9 2.3 2.6 2.9 3.1 3.2 3.1 3.1 3.1 3.1 3.13.0 2.9 2.7 2.5 2.3 2.0 1.7 1.4 1.1 0.80.2 0.3 0.5 0.8 1.1 1.4 1.8 2.2 2.5 2.8 3.0 3.1 3.0 3.1 3.1 3.0 2.92.9 2.8 2.7 2.6 2.4 2.1 1.8 1.5 1.2 0.90.2 0.3 0.5 0.8 1.0 1.3 1.7 2.1 2.5 2.7 2.9 2.9 3.0 3.0 2.9 2.8 2.72.7 2.7 2.7 2.6 2.5 2.3 2.0 1.6 1.2 0.9 0.70.3 0.5 0.7 1.0 1.3 1.6 2.0 2.4 2.6 2.9 2.9 2.9 2.9 2.7 2.6 2.5 2.62.7 2.7 2.6 2.5 2.3 2.0 1.6 1.2 0.9 0.70.3 0.5 0.7 0.9 1.1 1.4 1.9 2.2 2.4 2.8 2.7 2.7 2.7 2.4 2.3 2.3 2.42.6 2.5 2.7 2.6 2.2 2.0 1.6 1.2 0.9 0.70.3 0.4 0.6 0.8 1.0 1.3 1.7 2.0 2.2 2.4 2.4 2.4 2.3 2.2 2.1 2.1 2.22.4 2.4 2.4 2.3 2.0 1.8 1.5 1.1 0.9 0.7 0.50.3 0.4 0.5 0.7 0.9 1.1 1.4 1.7 1.9 2.1 2.1 2.1 2.0 1.9 1.8 1.8 1.92.1 2.1 2.1 2.0 1.8 1.6 1.3 1.0 0.8 0.6 0.40.3 0.5 0.6 0.8 1.0 1.2 1.4 1.5 1.6 1.6 1.6 1.7 1.6 1.6 1.6 1.7 1.71.8 1.8 1.7 1.5 1.4 1.2 0.9 0.7 0.5 0.40.3 0.4 0.5 0.7 0.8 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.4 1.41.4 1.3 1.3 1.2 1.1 1.0 0.8 0.6 0.5 0.3 0.20.2 0.3 0.4 0.6 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.1 1.1 1.11.0 1.0 1.0 0.9 0.9 0.8 0.7 0.5 0.4 0.3 0.20.2 0.3 0.4 0.4 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.9 0.9 0.9 0.9 0.90.8 0.8 0.8 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.20.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.70.6 0.6 0.6 0.5 0.5 0.5 0.4 0.3 0.3 0.2 0.20.2 0.2 0.2 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.50.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.20.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.30.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.10.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.20.2 0.2 0.2 0.2 0.2 0.1 0.1 0.11 fc1 fc1 fc1 fc1 fc1 fc1 fc1 fc0.5 fc0.5 fc0.5 fc0.5 fc0.5 fc0.5 fc0.5 fc0.5 fc0.25 fc0.25 fc0.25 fc0.25 fc0.25 fc0.25 fc0.25 fcGLEON SERIES W:\2016\16528A\CADD DATA\LANDSCAPE\_dwg Sheet Files\L1-1Plotted: 12 /21 / 2016 2:5 PMSUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION MONTICELLO DENTAL MONTICELLO, MN THE DAVIS GROUP 222 SOUTH 9TH STREET, SUITE 3255 MINNEAPOLIS, MN 55402 L1-1 LANDSCAPE PLAN 12/21/16 CITY SUBMITTAL REG. NO.23849 DATE Debra Brodsho 12/21/16 I hereby certify that this plan was prepared by me or under my direct supervision and that I am a duly licensed Landscape Architect under the laws of the State of Minnesota. Project Lead Checked By LANDSCAPE PLAN L1-1 N EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL WARNING: AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND Gopher State One Call 4116$#.. 64''2.#06+0)&'6#+. /+0  0Q5ECNG 64'' 70&+5674$'&':+56+0)51+. 6121($#..61$'Á .#;'4911&%*+2/7.%* 94#264''61(+456.#6'4#. /+0  2.#06+0)51+.$#%-(+.. 5#7%'4 (+0+5*'&)4#&' #$18'(+0+5*'&)4#&' $4#0%*+0) (#..10.; '37#..;52#%'&&')#4170& ÁZ56#-'5ž+0)4170& ÁZ56#-'5ž+0)4170& 56#-+0)"%1064#%614ž5126+10 64''5.#4)'46*#0 +0.+0'96470- 64''561 %'06'464''+0*1.' 0Q5ECNG 5*47$2.#06+0)&'6#+. #$18'(+0+5*'&)4#&' (+0+5*'&)4#&' 5#7%'4 2.#06+0)51+.$#%-(+.. .#;'4911&%*+2/7.%* 6121($#..61$'Á 70&+5674$'&':+56+0)51+.  /+0 4116$#.. /+0 PP03 2 PP03 4 PP03 3 PP03 1 NmmMOmobifjfk^ov=cillo=mi^k Ç~íÉW=NOLNOLNS " = ' " ëÅ~äÉW==NLU = =N JM 1/8" = 1'-0" PRELIMINARY FLOOR PLAN1 LEVEL 01 100' - 0" ROOF 114' - 7" PARAPET C 116' - 0" PARAPET A 122' - 4" VESTIBULE GLAZING 112' - 0" T.O. CANOPY 114' - 0" PARAPET B 118' - 0" T.O. GLAZING SILL 101' - 4" T.O. WINDOW SILL 103' - 4" FABCED PAINTED ALUMINUM CORNICE BUILDING NAME PAINTED ALUMINUM CORNICE EFIS BRICK PAINTED SILL PAINTED CMU SLIDING STOREFRONT ENTRY DOORS ANODIZED ALUM. WINDOW FRAME W/ TINTED WINDOW GLAZING T.O. WINDOW 109' - 2" LEVEL 01 100' - 0" ROOF 114' - 7" PARAPET C 116' - 0" PARAPET A 122' - 4" VESTIBULE GLAZING 112' - 0" T.O. CANOPY 114' - 0" PARAPET B 118' - 0" T.O. GLAZING SILL 101' - 4" T.O. WINDOW SILL 103' - 4" 1423 T.O. WINDOW 109' - 2" LEVEL 01 100' - 0" ROOF 114' - 7" PARAPET C 116' - 0" PARAPET A 122' - 4" VESTIBULE GLAZING 112' - 0" T.O. CANOPY 114' - 0" PARAPET B 118' - 0" T.O. GLAZING SILL 101' - 4" T.O. WINDOW SILL 103' - 4" F ABCED T.O. WINDOW 109' - 2" LEVEL 01 100' - 0" ROOF 114' - 7" PARAPET C 116' - 0" PARAPET A 122' - 4" VESTIBULE GLAZING 112' - 0" T.O. CANOPY 114' - 0" PARAPET B 118' - 0" T.O. GLAZING SILL 101' - 4" T.O. WINDOW SILL 103' - 4" 1 423 T.O. WINDOW 109' - 2" FINISH GRADE 1' - 4" 8"2' - 0"SIGN CABINET2' - 10"5"1' - 0"1" 1' - 6" 1" 1' - 4" 1"FOR EXACT SPECIFICATIONSSEE STRUCTRAL PLANS 4' - 10" BRICK PRE FINISHED CONCRETE CAP INTERNALLY LIT SIGN CABINET 6 PP03 FINISH GRADE 1" 4' - 10" 1" 5' - 0"1' - 4" 8"SIGN CABINET2' - 10"2' - 0"4"FOR EXACT SPECIFICATIONSSEE STRUCTURAL PLANS 4' - 10" 4" SIGN CABINET 4' - 4" BRICK PRE FINISHED CONCRETE CAP INTERNALLY LIT SIGN CABINET 3" 1' - 0" 3" 1' - 6" 1" FINISH BRICK FACE 1' - 4"1"4' - 4"1"FINISH BRICK FACE4' - 10" 1"5' - 0"PRE FINISHED CONCRETE CAP INTERNALLY LIT SIGN CABINET NmmMPmobifjfk^ov=bibs^qflkp Ç~íÉW=NOLNOLNS ëÅ~äÉW=^ë áåÇáÅ~íÉÇ 1/8" = 1'-0" PRELIMINARY ELEVATION - WEST1 1/8" = 1'-0" PRELIMINARY ELEVATION - NORTH2 1/8" = 1'-0" PRELIMINARY ELEVATION - EAST3 1/8" = 1'-0" PRELIMINARY ELEVATION - SOUTH4 1/2" = 1'-0" SECTION @ MONUMENT SIGN6 1/2" = 1'-0" ELEVATION @ MONUMENT SIGN7 1/2" = 1'-0" ENLARGED PLAN @ MONUMENT SIGN5 Building a legacy – your legacy. 701 Xenia Avenue South Suite 300 Minneapolis, MN 55416 Tel: 763-541-4800 Fax: 763-541-1700 Equal Opportunity Employer wsbeng.com K:\02596-390\Admin\Docs\LTR-a-schumann-MontSpecialtyClinic 020117.docx February 1, 2017 Ms. Angela Schumann Community Development Director City of Monticello 505 Walnut Street, Suite 1 Monticello, MN 55362 Re: Monticello Specialty Clinic Site Plan Review City Project No. 2017-007 WSB Project No. 02596-390 Dear Ms. Schumann: We have reviewed the civil plans, dated December 21, 2016 and the stormwater report dated December 20, 2016, as prepared by Loucks, Inc. and offer the following comments. Site Plan 1. City staff requested an interpretation of Chapter 2, Section 2.4, Subsection (O) for the site, which requires delineation of wetlands and/or watercourses within 200 feet of the perimeter of the property with a land use submittal. The subject property is within the 200- feet of the large wetland complex north of the site. A Level 1 wetland review was completed which included a desktop review of the site using aerial images and Wright County soil classification mapping. Based on this review, no physical impacts will occur to the identified wetland area. In addition, because the applicant is proposing to treat all stormwater onsite and will not increase runoff from the existing condition, no secondary impacts to the wetland area are expected. For these reasons, the subject property would not be subject to the regulations of the Wetland Conservation Act and a delineation is not required. 2. The retaining wall on northeast corner of site is approximately 6.5 feet tall and must be designed and certified by a licensed professional engineer. Provide a detail for the retaining wall include material type and color. SWPPP Plan 3. Identify the site disturbed area. February 1, 2017 Page 2 K:\02596-390\Admin\Docs\LTR-a-schumann-MontSpecialtyClinic 020117.docx 4. A NPDES/SDS Construction Storm Water General Permit shall be provided with the grading permit or with the building permit application for review, prior to construction commencing. 5. The applicant shall revise the SWPPP as needed to comply with the MPCA SWPPP checklist. Site Utility Plan 6. Move fire hydrant to north of the building entrance which will allow for better spacing with the hydrant on Deegan Court. 7. A utility excavation permit must be obtained from the Public Works department prior to commencement of utility connections. 8. Provide an as-built utility plan once construction is complete. Site Details 9. City standard detail plates 6003 related to construction entrances shall be included. Stormwater Management Plan 10. The existing stormwater pond north of the site accommodates rate control for the developed site. 11. Enclosed is a stormwater plan review checklist that identifies comments the applicant shall address. Please have the applicant provide a written response addressing the comments above. Please give me a call at 763-271-3236 if you have any questions or comments regarding this letter. Thank you. Sincerely, WSB & Associates, Inc. Shibani K. Bisson, PE City Engineer February 1, 2017 Page 3 K:\02596-390\Admin\Docs\LTR-a-schumann-MontSpecialtyClinic 020117.docx cc: Steve Grittman, NAC Enclosure skb October 2016 City of Monticello – Stormwater Site Plan Review A Stormwater Management Plan is required for: - Any land disturbing activity that may ultimately result in the addition of one acre or greater of impervious surfaces, including smaller individual sites that are part of a common plan of development that may be constructed at different times. - The construction of any new public or private road; or - Any land disturbance activity, regardless of size, that the City determines is likely to cause an adverse impact to an environmentally sensitive area or other property. Submittals Received Date Document Author 12/20/16 Stormwater Management Plan, Monticello Dental Loucks 12/21/16 Preliminary Plan Set, Monticello Specialty Clinic Loucks Project Narrative, Monticello Specialty Clinic Building B D H and Young General Site Plan Yes  No  1. Scale of Survey. Minimum scale 1” = 50’. Maximum size plan sheet 24” x 36” ☒ ☐ 2. Survey signed by a registered survey with elevations in NGVD-1929 datum for the following locations:  Each lot corner ☒ ☐  Grade elevation at the foundation and elevation of top of foundation of structures on adjacent lots ☒ ☐  Grade elevation at the foundation, elevation of top of foundation and garage flo or of proposed new construction ☒ ☐  Lowest point of entry (i.e. door sill or top of window well) of pro posed and existing construction ☐ ☒  Lowest floor of proposed and existing construction ☒ ☐ 3. Any proposed retaining wall must have a top and bottom elevation and bottom elevation would be finish grade. Also, no retaining wall is allowed to be built on private property ☒ ☐ Address: Monticello Dental Lot 2, Block 1, Prairie Ponds Permit No: PID: Date Approved: Date Received: 12/22/16 Signature: Site Size (acres): 1.67 ac Area of Disturbance(acres): 1.67 ac Existing Impervious (acres): 0 ac Proposed Impervious (acres): 1.04 ac October 2016 4. Retaining walls greater than 4.0 feet in height have been designed and certified by a licensed professional engineer and a building permit has been acquired ☐ ☒ 5. All drainage and utility easements are shown? ☒ ☐ 6. Easements are clear of any encroachments? ☒ ☐ 7. New curb cuts proposed? ☐ ☐ 8. If new curb cut is proposed, stamp all survey maps with the curb cut stamp. Also, write a note on the Residential Plan & Routing Approval form reminding the builder that a curb cut permit is required if the driveway is moved or a new driveway is added ☐ ☐ 9. Low floor a minimum of 4.25’ (feet) above the sanitary sewer invert elevation ☒ ☐ Comments: Proposed retaining wall has a maximum height of 6.5 feet. Documentation of design by a licensed professional engineer is required. Lowest point of entry of proposed building needs to be clearly shown on Sheet C3 -1. It appears as though a curb cut will be required. If so, it needs to be shown on the plans as described above. Erosion/Sediment Control Plan Yes  No  1. SWPPP notes provided on the plan ☒ ☐ 2. Temporary stabilization measures provided ☒ ☐ 3. Erosion control blankets provided on all slopes greater than 3:1 ☒ ☐ 4. Perimeter Control i.e., Silt Fence, Filter Log, etc. ☒ ☐ 5. Phasing for sites that are ≥ 1 acre ☒ ☐ 6. CB Inlet Protection ☒ ☐ 7. Dewatering ☒ ☐ 8. Sediment control ☒ ☐ 9. Waste control ☒ ☐ 10. Concrete washout ☒ ☐ 11. Rock entrance ☒ ☐ 12. Street sweeping schedule ☐ ☐ 13. Permanent restoration plan ☒ ☐ 14. Erosion protection at all outlet pipes ☒ ☐ 15. SWPPP includes an erosion and sediment control inspection schedule and per son responsible for maintenance ☐ ☒ Comments: “Site Data” notes need to be added to the SWPPP, including area of disturbance, pre-construction impervious area, post-construction impervious area and general soil type. A street sweeping schedule needs to be added to the SWPPP. The SWPPP needs to provide the name of the person responsible for SWPPP implementation and long term operations and maintenance of the permane nt stormwater management system, including certification number. Stormwater Management Plan Yes  No  1. Delineation maps for existing and proposed conditions ☒ ☐ 2. Modeling calculations for existing and proposed conditions using Atlas 14 storm events with an MSE3 type distribution. October 2016  2 year 24 hr. (2.84”), 10 year 24 hr. (4.22”), 100 (6.87”), 10-day snowmelt (7.2”) ☐ ☒  Modeled direct connected impervious separate ☐ ☒ 3. Off-site drainage included ☐ ☒ 4. Wetlands shown on plans and wetland permitting completed ☐ ☐ 5. Pretreatment ☐ ☒ 6. Skimmer structures provided on the outlets of all ponds. ☐ ☒ 7. Soil borings ☐ ☒ 8. Design Infiltration Rate Determination – Geotechnical Report or Infiltration Testing provided ☐ ☒ 9. Seasonal High Water Elevation ☐ ☒ 10. Open channel flow calculations ☐ ☒ 11. Storm sewer calculations – 10 year event ☒ ☐ 12. Narrative describing the following: a. Existing Conditions: Runoff rates for existing conditions were not provided. Drainage maps, modeling and summary for the 2-, 10- and 100-year storm events is required. b. Proposed Conditions: Runoff rates at all discharge locations were not provided. Drainage maps, modeling and summary for the 2-, 10- and 100-year storm events is required. c. Stormwater Management for Proposed Site: A discussion of pretreatment and infiltration feasibility should be included in the report. Comments: The HydroCAD model should include an MSE3 distribution for the Atlas 14 2 -, 10- and 100-year storm events. The stormwater report does not include this information. HydroCAD model output should be included in the report, along with a summary table showing the existin g and proposed discharge rates. Pretreatment of runoff is required prior to entering the infiltration basin. Soil borings are required in order to determine groundwater and bedrock elevations. There must be a minimum of 3-feet of separation from the bottom of the infiltration basin to the top of either bedrock or groundwater. Seasonal high water elevations were not provided. Soil boring logs and/or piezometer testing can be used to determine groundwater fluctuations. Runoff rates at all discharge locations from the site were not provided. The HydroCAD model should be modified to provide rates for the 2-, 10- and 100-year events. Off-site drainage from the lot to the south should be included in the HydroCAD model. It appears as though CBMH5 will receive off-site runoff. A detail drawing for the outlet control structure at the infiltration basin should be added to Sheet C8 -1. City design standards requires a minimum size of stormsewer pipe of 15 -inches. The proposed stormsewer includes 12-inch pipes throughout the site. Water Quality and Volume Reduction “The City of Monticello has adopted MPCA Minimal Impact Design Standards in Chapter 4 of Monticello Zoning Ordinance Section 4.10. MIDs Infiltration design criteria as described in the MPCA Stormwater Manual shall be followed for the proposed project.” Yes  No  1. Volume control provided as per the City’s Engineering Design Standards and MIDS (1.1” over new impervious surface) ☒ ☐ 2. Impervious area equal to or greater than the net increase in impervious surface is routed through infiltration BMP ☒ ☐ October 2016 3. Sequencing provided for alternatives where infiltration is infeasible ☐ ☐ 4. Required Volume Reduction: 4,162 cf 5. Provided Volume Reduction: 4,294 cf 6. Separation to groundwater and/or bedrock is a minimum of 3 feet from bottom of infiltration BMP ☐ ☒ 7. Drawdown time for infiltration BMP is within 48 hours ☐ ☒ 8. Proposed ponds meet or exceed NURP design criteria ☐ ☐ 9. If infiltration of 1.1” is not feasible, water quality goals are met with NURP pond on site? ☐ ☒ Comments: The overall feasibility of the infiltration basin cannot be verified without knowing the depth to groundwater and bedrock. Soil boring data is needed for this determination. The drawdown time for infiltration cannot be determined without infiltration testing. Documentation of how the design infiltration rate was determined is required. The infiltration basin is lined with filter fabric. Specifications for the fabric should be provided, documenting that it is soil tight and water permeable. An operation and maintenance plan is needed for all of the proposed BMPs at the site. Rate Control Yes  No  1. Peak Proposed Discharge Rates < Existing ☐ ☐ 2. Existing infrastructure can accommodate peak discharge rates for 10 year storm? ☐ ☐ 3. Existing infrastructure and EOF for proposed 100 year peak discharge rate? ☐ ☐ 4. Proposed flow patterns do not create flooding impacts for structures adjacent to the property? ☐ ☐ Comments: Rate control for the proposed project is planned to be provided at the regional basin to the north. However, discharge rates for the 2-, 10- and 100-year storm events should be modeled and summarized in the report. Freeboard Yes  No  1. Building Opening:  2’ above the critical 100-yr HWL of local basins, wetlands, & infiltration basins ☐ ☒  2’ above EOF of local basins, wetlands, & infiltration basins ☐ ☒  2’ above the 100-yr flow elevation of a swale or channel at the point where the swale channel is closest to the building ☐ ☒ 2. Low Floor Elevation:  2’ above the critical 100-yr HWL of major basins ☐ ☒  2’ above EOF of major basins ☐ ☒  For landlocked basins: 2’ above the HWL from back to back 100-yr rainfalls or 2’ above the HWL from the 100-yr 10-day snowmelt, whichever is higher. Starting elevation of the basin/waterbody prior to runoff is one of the following: o Existing Ordinary High Water level established by the Minnesota Department of Natural Resources ☐ ☐ October 2016 o Annual water balance calculation approved by the City ☐ ☐ o Local observation well records, as approved by the City ☐ ☐ o Mottled soil ☐ ☐ Comments: The low building opening elevation should be added to the planset. The HydroCAD model does not provide a 100-year HWL for the infiltration basin. When the model and planset are updated freeboard criteria can be evaluated for conformance to City standards. Planning Commission Agenda – 02/07/17 1 2B. Public Hearing – Consideration to recommend for the adoption the 2017 City of Monticello OfficialZoningMap. (AS) A.REFERENCE & BACKGROUND The Planning Commission reviewed the proposed 2017 Official Zoning Map at the regular meeting in January and recommended its’ approval. However, staff cross-checked the special use overlay district boundaries also reviewed at the January meeting and noticed a discrepancy between the proposed official zoning map and the boundary of the special use district. As such, the map presented for review and hearing in February now accurately displays the special use district boundary, consistent with the boundary reviewed by the Planning Commission in January. The special use overlay boundary is the only change from the January map. B.ALTERNATIVEACTIONS 1.Motion to adopt Resolution No. PC-2017-004 recommending the adoption of Ordinance No. 6XX for the 2017 City of Monticello Official Zoning Map, including Shoreland/Floodplain companion map, based on the findings in said resolution. 2.Motion of other. . C.STAFFRECOMMENDATION StaffrecommendsadoptionoftheCityofMonticelloOfficialZoningMapasproposed. D.SUPPORTING DATA A.Resolution No. PC-2017-004 B.Ordinance No. 6XX, Draft C.2017 Official Zoning Map, Proposed (dated 1/23/17) – including Shoreland D.Special Use Overlay Analysis, Map CITY OF MONTICELLO WRIGHT COUNTY, MINNESOTA PLANNING COMMISSION RESOLUTION NO. PC-2017-004 RECOMMENDING THAT THE CITY COUNCIL ADOPT AN AMENDMENT TO THE ZONING MAP IN ITS ENTIRETY WHEREAS, the Zoning Map of the City of Monticello requires amendment; and WHEREAS, the proposed map would accommodate and further the intentions and policies of the Comprehensive Plan; and WHEREAS, the proposed zoning would be consistent with the City’s land use plan; and WHEREAS, the Planning Commission of the City of Monticello finds that the proposed zoning map will be consistent with the intent of the Comprehensive land use plan and proposed zoning district; and WHEREAS, the Planning Commission has conducted a public hearing on January 3rd, 2017 and February 7th, 2017 to review the requests and receive public comment on the zoning map amendment; and WHEREAS, the Planning Commission finds that the proposed zoning map, including Shoreland/Floodplain map, has met the requirements for adoption as found in the zoning ordinance and state law; NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota: The Planning Commission recommends that the City Council adopt the zoning map amendment to be identified as Ordinance No. 6__. ADOPTED this 7th day of February, 2017 by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION By: _______________________________ Brad Fyle, Chair ATTEST: ____________________________________________ Angela Schumann, Community Development Director ORDINANCE NO. 6XX CITY OF MONTICELLO WRIGHT COUNTY, MINNESOTA AN ORDINANCE AMENDING AND ADOPTING THE 2017 OFFICIAL ZONING MAP FOR THE CITY OF MONTICELLO THE CITY COUNCIL OF THE CITY OF MONTICELLO HEREBY ORDAINS: Section 1. The zoning map amendments attached hereto and incorporated herein as Exhibit “A” are adopted as the Official Zoning Map under Title 10, Section 3.1 of the Zoning Ordinance for the City of Monticello. Section 2. This Ordinance shall take effect and be in full force from and after its passage and publication. Revisions will be made online after adoption by Council. Copies of the complete Zoning Ordinance are available online and at Monticello City Hall upon request. ADOPTED AND APPROVED FOR PUBLICATION BY the Monticello City Council this 13th day of February, 2017. CITY OF MONTICELLO _____________________________ Brian Stumpf, Mayor ATTEST: __________________________________ Jeff O’Neill, City Administrator VOTING IN FAVOR: VOTING IN OPPOSITION: ORDINANCE NO. 6XX EXHIBIT “A” Following are the approved amendments to the Official Zoning Map  Ordinance No. 644 – Rezoning the Monticello Middle School plat from A-O to R-1  Ordinance No. 645 – Rezoning the Pinewood Elementary parcels from A-O to R-1  Ordinance No. 649 – Rezoning the Monticello High School to Planned Unit Development  Ordinance No. 650 – Rezoning the Mills Fleet Farm plat from B-4 to Planned Unit Development  Ordinance No. 651 – Rezoning from B-2 to Planned Unit Development for Lot 1, Block 2, Oakwood Industrial Park (Red Rooster)  Ordinance No. 655 – Rezoning to from B-4 to B-3 for Camping World  Ordinance No. 656 – Rezoning from B-4 to B-3 for Lot 1, Block 1, 90th Street Addition (Moon Motors) County Hwy 75 Chelse a R d State Hwy 2585th St NE90th St NELinn StPine St7th St School Blvd Riverview Dr Cedar StW Rive r S t Marvin Rd Jason Ave Dundas Rd W Bro a d w a y S t Hart B l v d Country LaHaug Ave NEElm StW 4th S t Fenning Ave NEOakwook DrMallard La 95th St NE Fallon Ave NEEdmonson Ave NEMississipp i D r 5th St Co u n t r y C l u b R d Sandberg RdPelican LaFalcon Dr Fenning AveWalnut StOak Ridge DrOriole LaClub View Rd Bro a d w a y S t Hillcrest Rd E River S t Headman L a Mi l l Tra i l LaFalcon Ave NEWright StBenton StElwood RdRamsey St6th St River Mill Dr Wildwood Way Hilltop Dr Mill Run Rd Oak View La Farmstead AveMartin Dr 4th St E 3rd St E Red Rock LaGillard Ave NEMaple StFallon DrWillow StView La EGrey Stone AveMar v i n E l w o o d R d Fiel d c r e s t C i rFairway DrJason A v e N EVine StMeadow La Jerr y L i e f e r t D r Praire Rd Starling DrPalm StUnknown or No StreetnameFallon AveGolf Course Rd Falcon AveKevin Longley Dr Craig LaRed Oak LaFront S t 5th St W Thomas Park DrLocust StMockingbird La W 3rd S t Eastwood CirBriar Oaks Blvd F a rm s t e a d D r Henipin StEider LaDayton StOak L a River Forest Dr Meadow Oak Ave Kampa Cir Oak R idge C ir Mill Ct River Ridge La Garrison AveOakvi e w C tDundas CirKenneth LaOtter Creek RdMinnesota StEagle CirCrocus LaMe a d o w O a k L a Stone Ridge DrChestnut St120th St NE Dar r o w A v e N E Diamond Dr Pebble Brook Dr Widgeon LaWashington StBunker CirHomestead DrThomas CirEn d i co t t T rCenter CirOak View CirSandtrap CirCountry Cir Cheyen Ct Ol d T e r r i t o r a l R d Tanager CirHillcrest CirOsprey Ct Ac o r n C i rBalboul CirS w a l l o w C i r Riverside Cir Meadow Oak CtMatthew CirE Oak DrStone Ridge CirOakwood DrMeadow Oak Ave NECo u n t y H w y 7 5 Hart B l v dMarvin RdMarvin RdWright St90th St NECedar StMinnesota St01 02 03 04 City of MonticelloOfficial Zoning Map 01-23-17 :Legend BASE ZONING DISTRICTS Industrial Districts IBC I-1 I-2 Residential Districts -- Low Residential Densities A-O R-A R-1 Business Districts B-1 B-2 B-3 B-4 CCD-- Medium Residential Densities T-N R-2 R-PUD -- High Residential Densities R-3 R-4 M-H OTHER Water Mississippi Wild, Scenic & Rec Overlay District OVERLAY DISTRICTS Performance Based Overlay District !!!!!!!!!!!!Shoreland District Special Use Overlay District !!!!!!!!!!!!Freeway Bonus Sign District Mills Fleet Farm03 Red Rooster04 PUDs Swan River01 Monticello High School02 !"b$ ?¾A@ 92 n d S t N e 9 1 s t S t N eState Highway 25 SRiverForestD r Ne Fenni ng Ave NeG o l f C o u r s e R dMatthew Cir6th St WAlpineDr Heron CtWillow StElmStBunker CirI n n s b r o o k C t Chestnut StSwa l l ow Ci r 99th S t N e PelicanLnA l p i n e C t BisonAveFarmstead CtDeer CirTanager CirElkAveFoxStEakern AvePar kP lace Dr Crocus Cir WoodcrestCtMount C urve Blvd 4th St W M c k e n n a C t GatewaterDrMaple StOakr i d g e D r 89 t h StNe Gillard AveM i l l C tN eVine StC o u nt r y AveOttercreekRdBa d g er C i r Endic ottTrlR i v e r S t W C o u n t r y C i r Woodla n d C t TalonCt T r o y MarquetteDrR edf ordLnFieldcres tCir HaugA veNe 8 6 t h S t N e EiseleAveNeEiderLnBakk en St 9 3 r d St N eNicholas Cir8 2 n d S t N e Or char dCirEHawt hor ne Pl SD u n d a s R d S a n d TrapCirChelsea Rd W Deeg a n C t M e a d o w OakAv e N e O r i o l e LnWidgeon LnD e e r S t W i n d e m e r e C t O a k l e a f C tOakviewCirPrairie R d Harvest Ct Mill Trail L n N e D i a m o n d D r P a r k D rPrescottDrLinn StSum mit Ct B a d g e r S tWalnut StHart BlvdMinnesota St9 2 n d S t N e StateHighway25NeSandbergRd10 2 n d S t N e5thStW MeadowOakDrRiver St E Walnut St S3rd St ELocust StHennepin StRamsey StWright StRiver St W FrontSt 3rd St W S c h o o l B l v d C h e l s e a R dPalm StG o l denPon d LnNew StDundas CirWashingtonStO v e rlo o kLnBrentwood Dr 83 r d St N eInnsbrookDr7thStE T e r r i toria l Rd9 0 t h S t N eGillard Ave NeI c k l erAveNeVineLnOakviewCtCraigLnKennethLn TroyMarquetteLnS a v a n n a h A v e BearAv e BrightonAveNeOakwood Dr E M e a dowOakLnNe8 5 t h S t N e EbersoleAveHalsey Ave NeS t a r l i n g D r 4th St E K a mp aCirB r i a r O a kes BlvdHalsey Ave NeGoodrichDrNe Pinehur stCtCahillAveNeMallard L nGraystoneAve 9 0 t h S t N e 7 7 t h S t N eEagleCt Ide Ave NeH o m e steadD r9 6thSt N e OakRidgeCirDalton W ay 97th St Ne J erry L i e f e r t D r Orchard Ln Stoner i dg e Ln8 7 t h S t N e G a rveyCt Kevin Longley Dr Hamline Ave NeRiver vi e w D r N e 1 2 3 r d S t N e IbsonAveNeAetnaAve NeDa rlin gto n AveNeGiffortAveNeD altonCt DaltonAveNeH i l l t op Dr PrivateDrPine St8 7 t h S t Ne EastwoodCi r N e RedOak Ln N e A f ton A veNeHayw a r d CtSMarvinElwood RdHayward Ct N Sandy Ln M o c kingbirdLnF a l l on DrHarrington Ave Ne88 t h S t N eCrocusLn E a g l e R i d geLnPrairieCreek LnR e dRockLnFarmsteadAveRiver Mill Dr N e Edmonson Ave NeC l u b V i e w Dr W o o d s id e D rOakv ie w L nMeridianAveN Davern Ave NeDarrow Ave Ne9 4 t h S t NeHighlandWay Wi ldwood Wa y 7 9 t h S t N e C o u n t y R o a d 3 7 N e84thStNe Oakri d geDrNFallonAveNeW eston D r M a r t i n Dr 97th St Ne Fair hillLnMarvi n RdHed manLnSpruceDr 101st St N eT h o m a s P a r k D r E a s t O a k D r107th St Ne F a l c o n A v eDeeganAve119thStNe H illcr e s t Rd C o u n t y R o a d 3 9 NeA b e r t Av e NeCedarSt8 4 t h S t N eGilbertAveNe 80 t h S t N e WbI94ToPineSt C a m e r o n A v e N e 102ndSt Ne DaltonAve N e11 0th S t Ne E a kernCir N e9 5 t h S t N e HallA v e N eGoodrichAveNe116 th S t N e E Broadway St P i n e S t T o E b I94 Chamberl ain Ave NeC o u n t y R o a d 3 9 N e Cam eron Ave N eEb I94 ToPine St AetnaAveNeMillR u n Rd Mississippi Dr Ne Pine St T o W b I 9 4 AcaciaAveN eJaber Ave NeF e n n in g A ve Ne To E b I 9 4 7th St W ChelseaRd H a mil to n AveNe8 5 t h S t N e Garrison Ave NeW b I94T o F e n ningAve Ne 1 2 0 t h S t N e 12 7 t h S t N e Bradd ock AveNe7 5 t h S t N e 1 0 0 t h S t N e County Road 75 Ne 8 0 t h S t N e WBroadway St DavidsonAveNeJason Ave Ne 8 5 t h S t N e AcaciaAv e Ne HardingAveNeBria r w o o d A v eNeCounty Road 75 IffertAveNeInterstate94 1 inch = 1,500 feet Floodway Fl ood Fr inge 500-Year Floodplain DNR Protected Waters Wild and Scenic Boundary Shoreland Setback DNR Watercourse City Boundary ² Date: 2/12/2014 Source: WSB, Northwest Associated Consultants, City of Monticello, and Wright CountyMap date: April 2014 20 PARCELSAVAILABLE:67 ACRES 8 PARCELSAVAILABLE:41 ACRES 0 0.5 1 1.5 20.25 Miles ¯"Places toWork"Land Uses "Places toLive"Land Uses "Places forCommunity"Land Uses MonticelloRoller Rink 28 PARCELS TOTAL AVAILABLE:108 ACRES Schools Parks Sensitive Land Uses Residential Parcels Legend City Boundary Parcels ROW Water Industrial Parcels 2014 Adult Land Use Analysis Adult Use Parcels Available in Industrial/Special Use Overlay District Areas Industrial District/Special Use OverlayParcels Not Abutting Sensitive Uses Planning Commission Agenda – 02/07/2017 1 3A. Consideration of a request for simple subdivision resulting in two buildable parcels in the R-1 (Single-Family Residence) District to facilitate right of way for 7th Street/Fallon Avenue, per City Ordinance Title 11, Chapter 1, Section 7 Applicant: City of Monticello (NAC) Property: Legal: Lot 1, Block 1, Church of St. Henry PID: 155115001010 Planning Case Number: 2017 - 004 A. REFERENCE & BACKGROUND Request(s): Subdivision of a parcel to accommodate the City’s acquisition of right of way for the 7th Street/Fallon Avenue roundabout. Deadline for Decision: March 18th, 2017 Land Use Designation: Places to Live/Places for Community Zoning Designation: R-1, Single Residence District The purpose of the "R-1" single family district is to provide for low density, single family, detached residential dwelling units and directly related complementary uses. Overlays/Environmental Regulations Applicable: Freeway Bonus Sign Overlay District Current Site Use: Vacant/Open Space Surrounding Land Uses: North: Single Family Residential East: Church of St. Henry South: Interstate 94 - Industrial West: Multiple Family Residential Project Description: The parcel in question is the northwesterly most of several parcels that comprise the Church of St. Henr y campus. The parcel fronts on a portion of 7th Street, and is situated at the location where the Fallon Avenue overpass with intersect with 7th Street at a planned roundabout. The City proposes to acquire a portion of the subject parcel to accommodate right of way for the Planning Commission Agenda – 02/07/2017 2 roundabout project. The Church would retain the residual parcel adjacent to the remainder of the campus. ANALYSIS As noted above, the City is seeking to acquire a portion of an existing parcel, part of the Church of St. Henry plat. The parcel is question is 6.8 acres in area, and the City would acquire approximately 1.7 acres of that parcel for right of way purposes, with the remaining 5.1 acres remaining with the church. The Subdivision Ordinance, in Section 11-1-7, provides for simple subdivision of lots that are currently platted and do not create more than one new building lot. The Ordinance allows for such “simple subdivisions” to proceed without requiring a full plat or the normal public hearing requirements that larger subdivisions entail. Such subdivisions result in a “metes and bounds” description, essentially describing parts of the underlying platted lots. Occasionally, the County Recorder determines that the new descriptions are not recordable. While staff does not anticipate that likelihood in this case, in that were to occur, a plat would be required, and the applicants would need to reapply for a platted subdivision. The Subdivision Ordinance permits non-platted subdivisions under this exception to the general platting requirement: (A) In the case of a request to divide a lot which is part of an existing lot of record where the division is to permit the adding of a parcel of land to an abutting lot or to create two lots and the newly created property line will not cause the other remaining portion of the lot to be in violation with this ordinance or the zoning ordinance, except that no such division of a lot or parcel shall be permitted when said division shall create a lot or parcel that is in violation of Chapter 8, Subdivision 11-8-2, of this ordinance. For reference, Section 11-8-2 prohibits non-platted subdivisions creating more than 2 new parcels, and requires compliance with zoning standards as a qualification for the platting exception. The proposed subdivision is consistent with these principals, in that the newly created parcel will be utilized for right of way on the west (only public improvements would be made on this portion of the subdivision). For the remaining 5.1 acre parcel being retained by the church, the property would remain in its existing condition. Future Planning Commission Agenda – 02/07/2017 3 uses by the church, if proposed, would be subject to the normal zoning process, and would not be affected the subdivision. B. ALTERNATIVE ACTIONS 1. Motion to adopt Resolution No. PC 2017- 005 recommending approval of the simple subdivision for the City of Monticello and the Church of St. Henry, subject to the conditions in Exhibit Z. 2. Motion to deny adoption of Resolution No. PC-2017-005, based on findings to be cited at the Planning Commission meeting. 3. Motion to table action on the resolution, subject to additional information. C. STAFF RECOMMENDATION Staff recommends approval of the subdivision, based on findings that the proposed subdivision is consistent with the Comprehensive Plan and the requirements of the Zoning and Subdivision Ordinances, as well as compliance with the conditions identified in Exhibit Z. D. SUPPORTING DATA A. Resolution PC-2017-005 B. Aerial Image, Subject Site C. Subdivision Illustration and Legal Description Z. Conditions of Approval Planning Commission Agenda – 02/07/2017 4 EXHIBIT Z Simple Subdivision Lot 1, Block 1, Church of St. Henry Addition Conditions of approval for the proposed Simple Subdivision: 1. Conveyance of the 1.7 acre parcel from the current owner to the City of Monticello. 2. In the event the County rejects the descriptions of the metes and bounds subdivision, the applicant will need to re-apply and utilize a formal plat process. 3. Compliance with the requirements of the City Engineer regarding easements, grading, drainage, and utilities. CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC-2017-005 1 Motion By: Seconded By: RECOMMENDING APPROVAL OF A SIMPLE SUBDIVISION RESULTING IN CONFORMING BUILDABLE PARCELS IN THE R-1 ZONING DISTRICT TO PROVIDE RIGHT OF WAY FOR CITY STREET IMPROVEMENTS WHEREAS, the applicant has submitted a request to resubdivide a platted lot in the R-1 zoning district; and WHEREAS, the resultant parcels will meet or exceed the requirements of the R-1 zoning district; and WHEREAS, the property is designated as “Places to Live” and “Places for Community” on the Comprehensive Plan land use map; and WHEREAS, the subdivision will be consistent with the existing and future land uses of the surrounding area; and WHEREAS, the proposed subdivision meets the qualifying requirements for non- platted subdivisions according to the Monticello Subdivision Ordinance; and WHEREAS, the Planning Commission considered the item at an open meeting on February 7th, 2017 and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission of the City of Monticello makes the following Findings of Fact in relation to the recommendation of approval: 1. The resubdivision is consistent with the requirements of the zoning and subdivision ordinances. 2. The resubdivision will be consistent with the existing and future land uses in the area. 3. The subdivision, together with the conditions of approval recommended in the staff report on the item, will accommodate expected land uses for the neighborhood. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of Monticello, Minnesota, that the Planning Commission hereby recommends that the Monticello City Council approves the subdivision subject to the conditions listed in Exhibit Z as follows: CITY OF MONTICELLO WRIGHT COUNTY, MINNNESOTA PLANNING COMMISSION RESOLUTION NO. PC-2017-005 2 1. Conveyance of the 1.7 acre parcel from the current owner to the City of Monticello. 2. In the event the County rejects the descriptions of the metes and bounds subdivision, the applicant will need to re-apply and utilize a formal plat process. 3. Compliance with the requirements of the City Engineer regarding easements, grading, drainage, and utilities. ADOPTED this 7th day of February, 2017, by the Planning Commission of the City of Monticello, Minnesota. MONTICELLO PLANNING COMMISSION By: _______________________________ Brad Fyle, Chair ATTEST: ____________________________________________ Angela Schumann, Community Development Director City of Mon ticello - R equ est for Simple Su bd ivisio n Lot 1, Block 1, Church of St. Henry 1st Addition | PID 155-115-001010 C reated by : C ity of Monticello 385 ft CHU R C H O F ST. H E N R Y CHURCH OF ST. HENRY 1ST ADDITION Parcel Sketch Option Number 3B City of Monticello, Minnesota WSB Project No. 01494-480 Date: 6/14/16 Option Number 3B Fee Taking Description That part of Lot 1, Block 1, CHURCH OF ST. HENRY, according to the recorded plat thereof, Wright County, Minnesota, lying westerly of the following described line: Commencing at the most northerly corner of said Lot 1, thence on an assumed bearing of South 69 degrees 22 minutes 36 seconds East, along the northerly line of said Lot 1, a distance of 110.93 feet to the point of beginning of the line to be described; thence South 06 degrees 04 minutes 52 seconds West a distance of 105.10 feet; thence South 07 degrees 19 minutes 58 seconds East a distance of 225.34 feet; thence South 01 degrees 14 minutes 50 seconds East a distance of 94.63 feet to the southwesterly line of said Lot 1 and said line there terminating.K:\01494-480\Survey\Easements\Option Number 3B\ESMT EXBT-Option Number 3B.dwg Planning Commission Agenda – 02/07/17 3B.Consideration of Recommendation for Appointment of Planning Commissioner (AS) A.REFERENCE AND BACKGROUND: The Planning Commission is asked to consider recommendation on the appointment for the vacant position on the Commission. Prior to the regular meeting, the Commission will have had the opportunity to interview candidate(s) for the position. The recommended candidate will serve the balance of former Commissioner Buchmann’s term, which expires at the end of 2017. A listing of the terms is provided below for reference. The Commissioner’s terms are staggered in three year increments. Linda Buchmann (OPEN)3 yr 12/2017 appointed 1/12/15 Sam Murdoff 3 yr 12/2017 appointed 1/12/15 Brad Fyle, Chair 3 yr 12/2016 Marc Simpson 3 yr 12/2016 appointed 6/08/15 Lucas Wynne 3 yr 12/2018 Appointed 9/12/16 Charlotte Gabler Council liaison The Commission’s recommendation will be forwarded to the City Council on February 13th, 2017. B. ALTERNATIVE ACTIONS: 1.Motion to recommend appointment of _______________ to fill out the remainder of a three-year term on the Planning Commission. 2. Motion of other. C. SUPPORTING DATA: A.City Code Title 2, Chapter 1 - Planning Commission MONTICELLO CITY CODE TITLE 2 / Chapter 1 / Page 1 CHAPTER 1 PLANNING COMMISSION SECTION: 2-1-1: Name of the Commission 2-1-2: Authorization 2-1-3: Membership 2-1-4: Term of Office 2-1-5: Attendance 2-1-6: Vacancy 2-1-7: Officers 2-1-8: Meetings 2-1-9: Quorum 2-1-10: Duties of the Commission 2-1-11: Amendments 2-1-12: Compensation 2-1-1: NAME OF THE COMMISSION: The name of the organization shall be the Monticello Planning Commission. 2-1-2: AUTHORIZATION: The authorization for the establishment of this commission is set forth under Minnesota Statutes, Section 462, Municipal Planning Enabling Act. The planning commission is hereby designated the planning agency of the City pursuant to the Municipal Planning Act. 2-1-3: MEMBERSHIP: The Planning Commission shall consist of five members appointed by the Council. All members shall be residents of the City of Monticello and shall have equal rights and privileges. 2-1-4: TERM OF OFFICE: (A) Appointments. All members shall be appointed for three year terms ending on December 31st of a given year; however, said term may be terminated earlier by the Council. Terms shall be staggered so that no more than two members’ terms shall expire in a given year. Said terms are to commence on the day of appointment by Council. Every appointed member shall, before entering upon the discharge of his duties, take an oath that he/she will faithfully discharge the duties of office. (B) Renewals. When an expiring member’s term is up, such member may be reappointed by Council with the effective date of the new term beginning on the first day of the next year following the expiration. MONTICELLO CITY CODE TITLE 2 / Chapter 1 / Page 2 2-1-5: ATTENDANCE: It is the City Council’s intention to encourage Planning Commission members to attend all Planning Commission meetings. Should any Planning Commission member be absent for more than three meetings in a calendar year, that member may be subject to replacement by the City Council. 2-1-6: VACANCY: Any vacancy in the regular or at-large membership shall be filled by the City Council, and such appointee shall serve for the unexpired term so filled. 2-1-7: OFFICERS: (A) Elections. The City Planning Commission shall elect at its January meeting from its membership a chair, vice chair, and a secretary who shall serve for a term of one year and shall have such powers as may be prescribed in the rules of said Commission. (B) Duties of Chair. The chair shall preside at all meetings of the Planning Commission and shall have the duties normally conferred and parliamentary usage of such officers. (C) Duties of Vice Chair. The vice chair shall act for the chair in his absence. (D) Duties of Secretary. A secretary may be appointed who is not a member of the Planning Commission but can be employed as a member of city staff. The secretary shall keep the minutes and records of the Commission; and with the assistance of staff as is available shall prepare the agenda of the regular and special meetings for Commission members, arrange proper and legal notice of hearings when necessary, attend to correspondence of the Commission, and handle other duties as are normally carried out by a secretary. 2-1-8: MEETINGS: (A) The Planning Commission shall hold at least one regular meeting each month. This meeting shall be held on the first Tuesday. Regular meetings shall commence at 6:00 p.m. Hearings shall be heard as soon thereafter as possible. The Planning Commission shall adopt rules for the transaction of business and shall keep a record of its resolutions, transactions, and findings, which record shall be a public record. The meeting shall be open to the general public. (B) In the event of conflict for a regularly-scheduled meeting date, a majority at any meeting may change the date, time and location of the meeting. (C) Special meetings may be called by the Chair or two members of the Planning Commission together, as needed, and shall be coordinated with MONTICELLO CITY CODE TITLE 2 / Chapter 1 / Page 3 city staff. 2-1-9: QUORUM: A majority of all voting Planning Commission members shall constitute a quorum for the transaction of business. 2-1-10: DUTIES OF THE COMMISSION: The Commission has the powers and duties assigned to it under Minnesota Statutes, Section 462, Municipal Planning Enabling Act, by this Code, and state law. 2-1-11: AMENDMENTS: This ordinance may be amended as recommended by the majority vote of the existing membership of the Planning Commission and only after majority vote of the City Council. 2-1-12: COMPENSATION: Compensation of members of the Commission shall be as set forth in City Code for Fee Schedule. (#336, 11/22/99) (#337, 1/10/11) (#593, 3/10/14) (#607, 1/26/15) Planning Commission Agenda: 2/07/17 1 3C. Community Development Director’s Report. 1.Planning Commission Recommendations The City Council took the following action at its meeting of January 23rd, 2017 as related to items on the January agenda of the Planning Commission: •Consideration to amend the Monticello Zoning Ordinance, Chapters and Subsections as follows. Applicant: City of Monticello •Chapter 2, Section 4(F) – Site Plan Applications •Chapter 3, Section 4(E) – R-1: Single Family Residence District •Chapter 3, Section 4(F) – R-2: Single and Two Family Residence District •Chapter 4, Section 1(H) – Standards for Site Landscaping •Chapter 4, Section 1(J) – Zoning District Specific Landscaping Standards •Chapter 4, Section 5(J) – District Regulations •Chapter 4, Section 8(E) – Standards Applicable to All Uses •Chapter 5, Section 2(D) – Regulations for Civic and Institutional Uses •Chapter 5, Section 2(F) – Regulations for Commercial Uses •Chapter 5, Section 3(B) – General Standards and Limitations for Accessory Uses and Structures •Chapter 5, Section 4(E) - Specific Standards for Temporary Uses •Chapter 8, Section 2(B) – Lots City Council approved the ordinance amendment unanimously as part of the consent agenda. 2.Downtown Small Area Study Update The first meeting of the committee is scheduled for Thursday, February 9th at 4:00 PM at the Monticello Community Center, Academy Room. Attached are documents providing further reference on the small area planning effort for downtown. After the neighborhood and consultants have studied the neighborhood and talked to residents, they produce a report to be added as an addendum to the comprehensive plan. Th is report includes a survey of existing condi-tions and the goals and and objectives for the neighborhood. Additionally, the plan includes an implementation section that outlines the steps the neighborhood should take over the next ten years to achieve the goals.What is a small area plan?Neighborhood Master PlanStation Area PlanCorridor PlanTypes of small area plansWhat does a small area plan consider?A small area plan assesses the existing conditions of these categories and makes recommendations for how they can be improved over the life of the plan. It understands them as deeply interconnected and connects all categories to the larger goals for the plan.Quality and aff ordability of the housing stockWhere to focus new developmentViability of public spacesUrban character and designNatural resource pro-tection and integrationCultural expressionCondition of infrastruc-tureFriendliness of streets for all types of transpor-tationA small area plan is a policy document that establishes a long-range vision for land use and development for an area and formulates specifi c goals and projects to implement that vision. It functions as a supplement to the city’s comprehensive plan, providing fi ner detail on citywide goals and policies. Th e small area planning process typically begins when a neighborhood identifi es a need for long-term planning in the area and contacts the city. Th ey then bring in a planning and design consultant to assist in soliciting neighborhood participation, developing the goals, and writing the plan. Finally, the plan passes through a series of city approvals before becoming adopted into the citywide plan.What is the product of a small area plan? CITY OF MONTICELLO DEVELOPMENT SERVICES DEPARTMENT 505 Walnut Street, Suite 1 Monticello, MN 55362 Phone: (763) 295-2711 Fax: (753) 295-4404 Downtown Monticello developed as a place for residents and visitors to come together for commerce and recreation. Located in the historic area of the city and along the Mississippi River, our downtown is a unique neighborhood at the heart of Monticello. The downtown area has also been a central focus of planning efforts to recapture its vibrancy as a place for all people to enjoy its amenities. In 2010, the City of Monticello completed a guide to redeveloping downtown called the “Embracing Downtown Plan”. The plan considered land use, transportation and market realities for the area considered to be “Downtown Monticello,” extending from Interstate I-94 at its southern boundary to the Mississippi River in the north, and generally from Cedar Street on the east to Maple Street on the west. Since the adoption of the Embracing Downtown Plan, changes in the downtown marketplace have impacted the desire and ability to implement the land use part of the Embracing Downtown Plan as it was originally intended. In particular, the core downtown area requires a new perspective in terms of land uses most likely to be developed and successful. The City of Monticello Economic Development Authority (EDA) recently authorized a small area study of the core downtown area. The study is designed to:  Give revised land use direction to the core of downtown while supporting the overall direction of 2010 Embracing Monticello  Offer a fresh look at the current market conditions, how they have changed since 2010, and what the popular trends are.  Celebrate, strengthen and leverage the authenticity of Downton Monticello, its unique position in the region, and its existing amenities.  Create a usable plan that’s easy to read and exists in multiple formats.  Inspire investment with a planning process that focuses on practical solutions and existing market potential. The EDA is working with the Cuningham Group to accomplish this through a revised land use plan for the core downtown area. An essential part of the study’s planning process is a steering committee with ten representatives from City of Monticello commissions, the Monticello Chamber of Commerce, and interested citizens. Several public engagement sessions will also be held for residents and visitors to provide their thoughts and visions for the downtown. The steering committee and public engagement sessions will help guide the direction and evolution of the plan from start to completion, an anticipated timeline of February – June 2017. If you are interested in staying updated with the progress of the small area study or have any questions, please contact Jacob Thunander at jacob.thunander@ci.monticello.mn.us. Small Area Study – Downtown, Monticello